Instruction/ maintenance manual of the product NET IT PS600 Wybron
Go to page of 26
Net IT Net IT PS600 User Manual.
2 20620 Net- IT 20610 Net-I T P S- 600 Net -IT s oftw are v ersi on: 1.02 (wit h Inf oga te V2 .25) Man ual issu e da te: A pril 1 , 20 10 Table of Contents Safety Notice ................................................................................
3 Safety Notice SAVE THESE INSTRUCTIONS READ AND FO LLOW A LL INST RUCTIO NS This manual gives step-by-step instructions for preparation, setup and operation of the Net-IT. There is a potential risk of injury to persons if the product is not used as instructed.
4 Not es d e S écur ité EPARGNER CES INSTRUCTIONS LIRE ET SUIVRE TOUTES INSTRUCTIO NS Ce m an uel d onn e de s ins truc tions po ur la prep ara tion, l’org anis atio n, et l’op érati on d u le N et- IT prov ision d'éle ctric ité.
5 Avi so S obr e S egur ida d SALVE ESTAS INSTRUCCIONES LEA Y SIGA TODAS INSTRUCCI ONES Este ma nua l da el pa so p or p aso las i nstru ccio nes para la p rep arac ión, para arre glo, y pa ra la op erac ión de l a Ne t- IT fuente del poder.
6 Sic herh eits hinw eis e BEHALTEN SIE DIESEN ANWEISUNGEN LESEN SIE UND GEHORCHEN SI E ALLEN ANWEISUNGEN Dies es H and buc h gi bt S chrit t für Schr itt A nwe isun gen zur V orb ereit ung, Auf stell ung, und Fun ktio n de m Net - IT Qu elle der Kraf t.
7 Introduction The Net-IT takes what are currently two different boxes, a DMX-over-Ethernet Output Node, and a two-universe RDM Controller (IT Gateway), and combines them into a single box. Instead of wiring up to two different boxes and configuring each, this product will make this process easier, simpler and decrease failures points.
8 Quick Start Guide The Net-IT ships with a default static IP address that is unique for each unit shipped. Upon powering the unit, you will see the default IP address and sub-net mask on the front panel backlit display. Press the front panel Page button to scroll through the information to find the IP address for the following procedure.
9 byte of the IP address. When the Network Switch is in the OFF position the unit will use an IP address of 2.x.x.x. When the switch is on it will use an address of 10.x.x.x per the Art-Net standard. You can override this address convention by manually entering a full IP address.
10 Sample Web page for Art-Net configuration.
11 Sample Web page for E1.31 configuration.
12 Net-IT Connection Diagram Info ga te Sof twa re Ne t- IT Eth ern et Lig htin g co ns ole Wybron Pow er ed 4 pi n 5 p in D MX Un iver se A Un iver se B Wybron PS - 600.
13 Net-IT PS-600 Connection Diagram Info ga te S oftw ar e Ne t- IT PS - 600 Eth ern et Lig htin g co ns ole Wy bro n Pow er ed 4 pi n Un iver se A 5 p in D MX Un iver se A Un iver se B.
14 Front and Back Panels See the diagram on the next page. The Ne t IT ha s one IE C u niv ers al p ow er c onn ect or . The re are two 5- pin XL R o utp ut p orts loc ate d o n th e u nit. The se are la be led “Po rt A ” & “Po rt B ” and ou tpu t DM X /RD M o n t wo univ ers es .
15 Fro nt Bac k 1 LC D S cre en 2 Page button 3 RD M A LE D 4 RD M B LE D 5 Line Speed 100Mbps 6 DM X A ou tpu t 7 DM X B ou tpu t 8 Eth ern et c onn ect or 9 Pow er LE D 10 DM X A LE D 11 DM X B LE D 12 Fus e 2 50V 1.
16 Net-IT Operation Net-IT sample screens in Art-Net mode. The front panel display shows the current settings. Changing most of the settings is done through the Net-IT web page. To get to the web page read the IP address off the display, open a browser on your PC or Mac, and enter the IP address in the top line of the browser.
17 Setting the DMX Universes On the web page go the DMX A or B Universe field and enter a universe number. Then click Submit. For Art-Net you may also select the DMX subnet and network switch. In Art-Net there are a possible 256 universes that are selected through 16 subnets which each contain 16 universes.
18 Net-IT PS-600 Head-Feet Restrictions The HEAD-FEET parameter is a method of accounting for the voltage drop in the power/signal cable caused by the current drawn by each device. To help understand this issue, think of it as water pressure (voltage) in a hose (cable) where you have multiple water sprinkler heads (color changers).
19 The following is a chart of capacity of the Net-IT PS-600 for the companion devices. Des cript ion Mo del Ma x. He ad- Fee t per Outp ut con nect or Ma x De vice s per Net- IT PS - 600 NexeraLX - tungsten 2560, 2570 1500 32 NexeraLX - CDM 2580, 2600 1500 24 Forerunner – 4 inch 4540 7140 1500 64 Coloram IT 4 & 7.
20 InfoTrace RDM System Overview The heart of the InfoTrace (IT) system is the Net-IT and InfoGate PC or Mac software — specialized hardware and software that uses the bi-directional communications protocol, Remote Device Management (RDM), to facilitate remote addressing and diagnostics for potentially every piece of equipment mounted on a rig.
21 Troubleshooting Problem Net-IT will not connect to my Art-Net or E1.31 network. Solution On the Net-IT display, read the IP address and subnet mask. Verify what the IP address and subnet mask is of your network. If they are different, then connect the Net-IT directly to a PC or MAC with an Ethernet crossover cable.
22 Problem Screen is frozen or the screen is showing an error message. Solution If you cannot scroll through the page feature then the software has been corrupted, call Wybron Tech support Recycle the.
23 Cables Power/ Data Cab le The Power/Data Cable uses 4-pin XLR connectors on either end and consists of two 14 AWG conductors and a 22 AWG twisted, shielded pair. The shells of the two XLR connectors are not electrically connected together -- this prevents large power currents from flowing from chassis to chassis of the equipment.
24 Appendix A - Definitions, acronyms and abbreviations ACN – the EST A A rchi tectu re fo r Co ntro l Ne twor ks s tand ard [ ACN ]. It spec ifies an arch itect ure — including a suite of pr otoc.
25 Warranty Information WY BR ON , IN C. wa rran ts t o th e o rigi nal own er or r etai l cu sto mer tha t fo r a per iod of o ne yea r from d ate of d eliv ery of a p ort able sy ste m o r en erg iz.
26 User Manual Revision History Date Auth or Des cript ion 4/1/2010 Pau l Ge isler Orig inal rele ase.
An important point after buying a device Wybron NET IT PS600 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Wybron NET IT PS600 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Wybron NET IT PS600 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Wybron NET IT PS600 you will learn all the available features of the product, as well as information on its operation. The information that you get Wybron NET IT PS600 will certainly help you make a decision on the purchase.
If you already are a holder of Wybron NET IT PS600, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Wybron NET IT PS600.
However, one of the most important roles played by the user manual is to help in solving problems with Wybron NET IT PS600. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Wybron NET IT PS600 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center