INSTRUCTIONS When using an electrical appliance, basic precaution must
SAFETY
always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE. This machine is for commercial use.


WARNING:
ONLY. ELECTRICAL: In the USA this machine operates on a standard 15 amp 115 volt A.C. power circuit

(12OV nominal). Special voltage models are available for interna- tional applications. The amp, hertz and voltage are listed on the data label found on each machine. Using voltages above or below those indicated on the data label will cause serious damage to the motors.


EXTENSION CORDS: If an extension cord is used, the wire size must be the same type and at least one size larger than the power cord on the machine. Do not use over 50 ft.

(15m) of extension cord(s). The machine is equipped with a 50 ft.
SJTW/-A power cord.


malfunction or break down, grounding provides a path of least resistance for electric current to re- duce the risk of electric shock. This appliance is equipped with a cord having an equipment- grounding conductor and grounding plug. The plug must be inserted into an appropriate outlet that is properly installed and grounded in accor- dance with all local codes and ordinances.

This appliance is for use on a nominal
120-volt circuit, and has a grounded plug that looks like the plug in Fig. A. A temporary adaptor that looks like the adaptor in Fig. C may be used to connect this plug to a 2-pole receptacle as shown in Fig. B if a properly grounded outlet is not available. The temporary adaptor should be used only until a properly grounded outlet (Fig. A) can be in- stalled by a qualified electrician. The green col- ored rigid ear, lug, or the like extending from the adaptor must be connected to a permanent ground such as a properly grounded outlet box cover. Whenever the adaptor is used, it must be held in place by a metal screw.


Fig. C


(15m) · 14/3


Adjust brush to proper cleaning position by using lever located on the front of the frame. Start at No. 1 “new brush” (black) position. If more carpet pile agitation is desired, lower brush setting one posi- tion at a time. (See fig. 1 below)
f-












115V Model Rear Panel
230V Model Rear Panel

Filling Solution Tank:
For Hard Floor: 1.) Install the optional kit : Vac Shoe Squeegee (p/n 02285). Raise the SPD vac shoe and place the squeegee assembly over the vac shoe intake. Center the squeegee on the vac shoe and secure by tightening the two retain- ing knobs.
1.) Set dome and recovery tank to the side.
2.) Use a clean bucket to fill the solution tank
with hot water.

2.) Now install the hard floor brush. Tilt the machine back far enough to grasp the brush. If the carpet brush is already installed, proceed with step 3 to remove it. If no brush is installed, proceed with step 4.
3.) If necessary add a cleaning concentrate for use in hot water extractors. Closely follow manu- facturer’s instructions found on container. Read ingredients listed on the container to ensure
3.) To remove brush, pull the brush release knob back until the brush can be swung out from the housing and pull the brush off of the drive end.
4.) To replace, align the pulley drive pins on the knob driver in the housing with the slots in the brush and slide over the knob driver.
the flat sides of the brush stub axle in the housing and swing the brush into place. Then release the knob, returning to the locked position. Refer to page 17 for parts outlined in these steps.
5.) Pull the brush release knob back, align
SUITABLE INCOMPATIBLE CHEMICALSCHEMICALS Alkalis Clorox II Bleach* Defoaming Agents Detergents Hydroxides Oxygen Bleaches Soaps Sta-Puf Fabric Softener* Vinegar White Monday Bleach*
Aldehydes Aromatic Hydrocarbons Butyls Carbon Tetrachloride
6.) Set the water control switch on the front of the machine to “LOW”. NOTE: If water does not spray after 5 seconds when the switch is in the “LOW” position it may be necessary to place it in the “HIGH” position to start the flow, then return it to the “LOW” position for hard floor use.
Clorox* Chlorinated Bleaches Chlorinated Hydrocarbons D-Limonene
Lysol* Methyls (MEK) Perchlorethylene(perc) Phenols
For Carpet: 1.) Remove squeegee from vac shoe by loosening the two retaining knobs.
l Registered Trademark Trichlorethylene
2.) Install carpet brush as described above.
4.) Place the recovery tank onto the solution tank.
3.) Set the water control switch on the front of the
5.) Set the dome in place on the recovery tank.
machine to “HIGH”.
Dome must be seated correctly to ensure
proper vacuum seal.
com-

tank.
area.
floor.
floor.
height.
tank.
outlet.
tank.
foot.
lock.
handle: A.
completed.
foot.
dry.
handle.
drain.
on.
maintenance.
floor.
dry.
on. NOTE: Starting the machine with dry brush rest- ing on floor may trip the brush motor circuit breaker.
When not using the machine put the brush in the storage position. (see daily maintenance on page 8) Leaving the brush on the floor for long pe- riods of time may ruin It.
solution. 10.
pace.
m).
efficiency. 11.
up. 12.
tank.
package.
carpet. An overflow of foam from in the recovery tank into the vacuum intake can damage the
vacuum- motor. Always be aware of the waste water level and foam in the recovery tank, es ecially when using an accessory tool.
solu- tion is pulled into vac intake empty the recovery tank.
Never put defoaming compound in the solution tank. Damage to pump will result.

15.) Ventilate the room when cleaning has been completed. Keep all traffic off the floor until it is thoroughly dry.
Standard Floor Wands (SFW, SW, or SW-PRO) Deluxe Hand Tool
(DHT) Upholstery Hand Tool (UPH3)
16.) When done cleaning for the day bring the machine to a utility sink and floor drain. Perform the daily/regular maintenance. Set the recovery tank aside so solution tank will dry. CAUTION:
Floor Surface Inspection: Determine precisely what areas you are going to clean. Note the problem areas in the carpet or hard floor. Look for loose carpet, heavily dam- aged areas, discolored stains or grease spots that will require prespotting. Note the carpet or
When not using the machine put the brush in the storage position. (see daily maintenance on page 8) Leaving the brush on the floor for long periods of time may ruin it.
hard floor type. Check the availability of hot wa- ter, drains, and suitable electrical outlets. If the carpet is loose or worn or there is hard floor sur- face flaking, have it repaired before attempting to clean it.
1.) Turn the machine completely off and unplug it from electrical outlet.
Plan Cleaning Route: Work from the most remote area towards the exit. Try not to travel over the cleaned areas when getting fresh water or dumping old. Furni- ture should be moved away from the walls be- fore cleaning. If furniture is moved back in place before floor is completely dry, place plastic or foil protectors under the legs to prevent possible staining. When possible use a Windblower
2.) Connect the solution hose to the brass fitting on lower left side of machine.
3.) Connect the vac hose to the left side of the dome (side with white hose cuff).
4.) Fill the solution tank.
(WB3) and open all windows and doors to speed drying.
5.) Plug the machine in and turn on only the vac/pump switch. Also place the water control switch in the “HIGH” position. CAUTION:
General Cleaning Information: Vacuum carpet or sweep hard floor first! Al- ways take the time to thoroughly vacuum carpet or sweep floor before using the extractor.
Using accessory tool with brush switch on may damage floor.
On heavily soiled floors, or on areas of high foot traffic, it may be necessary to use a
pres- pray or traffic lane cleaner applied with a sepa- rate sprayer. Do not add presprays to the ma- chine’s solution tank. If a spotter is used, follow the manufacturer’s instructions exactly as
6.) Turn off the machine and unplug it from electrical outlet before disconnecting accessory tool.
printed on the label. Spotter left on the floor may bleach or brown it permanently.

Shag or deep pile carpets may require several passes from different directions, but the opera- tor must be careful not to over saturate the car- pet. Make several passes without spray to ex- tract as much moisture as possible.

Rinse carpet after cleaning so that sticky soap build-up will not cause carpet to quickly become soiled again. Go back over carpet using only clean warm water in solution tank.


OF
Dailv Maintenance: These procedures are followed at the end of each work period to extend the life of the ma- chine.
INJURY
1.)
Empty unused cleaning solution by disconnecting clear hose on back of machine and pouring into floor drain.
This product contains moving parts.
machine before servicing.
Inspect and clean solution filter screen inside tank and vac intake screen inside dome.
Maintenance and repairs must be done by qualified personnel ONLY.
Flush the system. Fill solution tank with 1 or 2 gallons (4
- 8 liters) of clean hot water. With machine over floor drain turn on vac/pump switch until solution tank is empty.
Inspect spray pattern of jets. Remove jets and rinse if clogged.
After each use, rinse recovery tank with fresh water. Periodically inspect the
5.)
recovery tank and decontaminate if necessary, using a Hospital Grade Virucide or a l-l 0 bleach to water solution. Waste water should be disposed of properly.
115V Cord Assembly (USA/Japan) 23572 230V Cord Assembly (Europe) 23178
Remove any lint or debris from brush.
Dome Gasket 35060 Hose Cuff. Short Blue 27508 Hose Cuff. Longer Blue 27354 Hose Cuff, White 27079 Jet Assembly 44055
Inspect power cord. Remember, this cord will lay on a damp surface.
Warning:
IMMEDIATELY REPLACE WORN OR FRAYED POWER CORDS.
Jet Seal 44051 Jet Body w/Seal 44052 Manifold Assembly
Jets) 54094 Pump Service Kit 47176
8.) Inspect hoses. Worn or cracked hoses may cause loss of vac pressure.
Screen/Filter, Dome 34140 Screen/Filter, Solution Tank 73250 Solution Release Cable 27665 Solution Release Lever 51200
9.) Place the brush in the storage position. Press back slightly on the main handle, and place the brush adjustment lever in the
“STORE”position. For infrequent use or long periods of stor- age, flush the system with a neutralizing solution of 1 quart (1 liter) white vinegar mixed with 2 gal- lons (8 liters) hot water. Flush the system with clean hot water after neutralizing.

Periodic Maintenance: These procedures are performed by a trained service technician. The regularity of these procedures may depend on the ma-
chine's use.
machine to freeze will cause damage not covered by the 6-3-1 warranty.
Flush the system with a special solution to reduce scaling (alkaline build-up).
Use acetic acid (white vinegar) or an anti-browning solution. Mix one quart acetic acid with 2 gallons
(I:8 liters) of hot water in the solution tank (if an anti-browning solution is used follow manufacturer’s instructions). Turn on the vac/pump switch and allow the
Use a methyl hydrate window washer type anti-freeze; mix a gallon or two (4-8 liters) of anti-freeze solution, following the manufac- turer’s instructions. Add the anti-freeze solution to the solution tank. With the hoses in place run the machine until the anti-freeze begins spraying out (don't empty solution tank). Vacuum out the remaining anti- freeze solution in the solution tank. Discon-
machine to run over a floor drain until the solution tank is empty
(approximately once a month).
Inspect hoses and cords, replace as needed.
2.)
nect the hoses and empty the recovery buck- et. Always allow the unit to return to room temperature before filling with hot water or operating.
3.)
Inspect filter screens, clean or replace as needed.
4.)
Inspect spray pattern of jets, replace or clean as needed.
5.)
Check the tension of the solution valve cable, tighten if necessary.
Inspect the vac motor, remove any lint build-up at cooling intake, service carbon vac motor brushes
6.)
(Approximately every 750 operation hours).
With the machine running, the brush should rotate freely without rattling or grinding. Replace bearings if necessary.
7.)

Check building circuit breaker.
Test switch for continuity/Replace if necessary.
Test circuit breaker for continuity/Replace if necessary.
With the machine unplugged, check for, and correct, any loose wire connections inside the machine at the switches and terminal block.
Follow grounding instructions exactly.
Have an electrician inspect the building’s wiring.
Ensure that the machine’s wiring matches the appropriate wiring diagram. Check for and correct any loose wire connections. Replace any wires or components which are short circuiting.
Brush is adjusted too low, adjust position using the adjustment control at the front of machine. Best cleaning results are achieved with a minimal brush/surface contact of less than
3/8” (1cm).
Turn brush motor and pump switches on with machine tilted rearward
(brush off floor). Lower machine back to carpet slowly.
Test circuit breaker for continuity/Replace if necessary.
Higher amp draws may indicate a mechanical problem. Find parts which are not moving freely and repair or replace.
Vacuum Motor Speed Varies or Doesn’t Run: Worn motor brushes
Check for and correct any loose wire connections,
Center dome over tank.
Crack in dome or poor joint
Replace or repair using acrylic plastic cement only.
Tighten cuffs (turn counter clockwise).
Replace gasket.
Lint or dirt clogging vacuum intake screen
With power off clean vac intake screen found in dome.
Clean out tool, ensure free airflow.
Have a trained service technician inspect and repair the machine.

Accessory Tool Fitting Difficult to Connect:
Clean with steel wool.
Remove and soak in acetic acid (white vinegar).
Lubricate lightly with silicone base lubricant.
Make several passes at right angles to each other.
Use a prespray.
Replace spray jets which are producing more than a fine mist.
Clean solution filter screen located inside lower tank near the front.
Clean or replace jets.
Do not use a wire to clean jet.
Damaged jets will cause over-saturation.
Check for and correct any loose wires
Adjust solution valve cable until valve operates when handle is pulled.
Remove belt cover on right side of machine. Inspect belt. Replace if necessary.
Replace.
Replace.
If the belt, circuit breaker, and switch have been tested and found to be in good working order, the brush motor may need to be replaced.
Replace bearings.

To access the vac motor first remove the solution tank. There are (2) screws which attach the vac motor mounting bracket to the chassis. Loosen the clamp to remove the hose. To replace the motor assembly it will be necessary to remove the (3) screws which attach the motor to the vac motor mounting bracket. See page 18 for the complete vac motor and mounting equipment parts list.




1 The green ground wire must attach the motor to the power cord for safe operation. I

See wiring diagram. I

If armature commutator is not concentric, extremely pitted, or grooved the motor will need to be replaced or sent to a qualified service center to restore vac performance.
size) Periodically check the length of the carbon brushes.

3/8” long.
loosen wire terminal BEFORE removing screws on bracket.
(actual






















.OlO
BHCS
.O
PHMS
OD 10
Washer.
Washer:

&
SOLUTION
TANKS






damage.
machine.







&
TANK ASSEMBLY
Parts List

l/4 Flat 3 73280 Spacer, 1/4 ID x 3/8 Nylon 4 38088 Handle, Recovery Tank 5 75078 Tank, Recovery 6 14042
Bushing, 1.63 ID Snap 7 39343 Hose, 1.5 x 34” Vac 8 39411 Hose, 1.5 x
52” Vac 9 27079 Cuff, White 1.5 Hose 10 27508 Cuff, Short Blue Hose 11
27354 Hose cuff, blue 12
28033 Dome Asm 13
50775 Label, Warning Explosion Vert 14
50776 Label, Warning For Safety


ID
W
I/4-20
.O
IO
PHMS
MPT
NPT
SPR
15VA
OV








Rinse in hot water or use compressed air to clean. Nozzles can also be soaked in an acetic acid solution (white vinegar).







Replace jets that no longer produce a fine mist spray or over saturate carpet.
‘23



.1/4
FPT

FPT
PSI
OPEN

J
MPT
PHMS

1/4MPT
Clamp.
Hose:



Hose.















See page 4 for panel configuration














Parts
List
Nut, 10-32 w/Star Washer
5 41236 Hub Cap,
l/4-20 x 1.25 HHMS
Spacer, 5/16 x 1.2” Spacer,
5/16 x 1” Linkage, Handle Adjustment
38269 41302 Handle, SPD II Housing, Solution Lever
l/4-20 Nylock Grip, 9.5” Handle
Hook, Cord Scr, 10-32 X
Nut, 10-24 Joint Connector Lever, Solution Clip, Solution Cable Cable,.06X41.3.0707.
57113 Clip, Power Cord Nut, 5/l6- 18 Nylock
l/4-20 x 1.75 HHMS Washer,
318 Nylon Flat Scr,
3/8 5/l6- 18 SHSB Label, 15 Amp Time Delay Fuse Switch, 250V
16(4) rckr SPST Panel, Electrical Panel
115V Nut, 10-24 Tinnerman Clip, Switch retainer Scr,
l/2 sht metal blk Strain Relief Label, Handle Adjust Scr, 10-32 x
#lO Ext. Star Control Asm,
115V SPD (pump) Scr, 6-32 x
3/8 PHTF Cord Asm,
Scr, 10-24 truss head pltd Nut,
5/16- 18 jam pltd Tape,
l/32 x 1.0 25A Label, ETL approval Gasket, Right Frame Top Plate, Tray Top
Gasket, 8” Clamp Seal Gasket, Left Frame Top



DRIVE
ASSEMBLY






To access the belt remove the belt cover.
To replace the belt it is necessary to loosen the motor and remove the brush.

The “preset” belt tension is correct when the motor and belt securely back in place.


Check pulley alignment and correct if necessary. The brush pulley and motor pulley can be aligned using a straight edge.



Ensure that both protective covers are back in place before operating the machine.


are


Bearing, Brush Shoulder bolt,
Brush, SPD Carpet Brush, SPD Hard Floor Brush, SPD Hard Floor (Grit) Washer, 1/2 ID x 1.0 OD x
.06 nyl Guard, Thread Scr,
.25 Scr,
.259 ID x
PHMS Housing, Brush Scr,
l/4-20 x 1/2 HHCS
l/8 OD pop wht alum Pin, Roll
l/4 OD x 1.375 L Nut,
19B
l/3 HP W/O TO Washer,
Flat Scr, 10-32 x
23 36044 24 70363
Guard, belt Scr, 10-32 x 3/8 PHTR Belt Nut,
l/4-32 Nylock Gusset, Belt Guard Scr, 6-32 x 3/8 PPHTP Guard, Brush Pulley Washer,
3/4 HHCS Pulley, 2
l/8 OD 7 groove Ring,
l/2 ext. snap
Scr, 1O-24 x 112 SHCS Driver, Brush SPD Spring, Brush retaining Knob, Brush release Cable, Brush release Scr,
PHCS pltd. Nut,
pushlock Set Screw, 8-32 x
5/16 KCP
Brush Asm, SPD Carpet
Brush Asm, Hard Floor
Brush Asm, Hard Floor (Grit)















Front · of · frame







Nut.
ID
OD
ID
OD
PHTF














To attach to the SPIRIT DUAL...
Raise the SPD vac shoe and install squeegee assembly over the vac shoe intake. Center the squeegee on the vac shoe and se-
cure by tightening the two retaining knobs.














LIMITED WARRANTY Windsor Industries, Inc. warrants new machines against defects in material and workmanship under normal use and service to the original purchaser. The warranty period is subject to the conditions stated below.

3 YEARS FOR PARTS AND I YEAR FOR SERVICE LABOR Exceptions: Rotationally molded polyethylene tanks carry a 6 year parts and 1 year service labor warranty. VERSAMATK models carry a 3 year warranty on brush motors, vacuum motors, and belts, and a 1 year service labor warranty. SENSOR” models carry a 2 year warranty on vacuum motors and belts, and a 1 year service labor warranty. Extractor brush motors, pump motors, pc boards and electronics,
vat motors (other than VERSAMATIC” and SENSOR”), pumps, and
FLEXSOLTM diaphragms, all RADIIUSTM, all
TITANTM1 carry a 1 year parts and service labor warranty. Propane equipment has a 1 year parts and service warranty. The
Onan” engines have a 3 year manufacturers’ warranty. The Honda@ engines have a 2 year manufacturers’ warranty. The engine warranty is administered through the engine manufacturer and must be repaired at an authorized service center.
Normal wear items including, but not limited to, belts, brushes, capacitors, carbon brushes, casters, clutches, cords, filters, finishes, gaskets, hoses, light bulbs, rectifiers, switches, squee- gees, bearings, pulleys, relays,
actwating cables, tires and wheels will be warranted for manufacturing defects for 90 days from the purchase date.
The warranty commences on the purchase date by the original end user from an authorized Windsor Agent, subject to proof of purchase. The Machine Registration Card must be completed and returned immediately at the time of purchase. If proof of purchase cannot be identified, the warranty start date is 90 days after date of sale to an authorized Windsor distributor. Parts replaced or repaired under warranty are guaranteed for the remainder of the original warranty period.
90 DAY WARRANTY EXTENSION AVAILABLE Upon receipt of the Machine Registration Card, Windsor will extend the warranty period an additional 90 days from the purchase date. Does not include items warranted 90 days for manufacturing defects.
STATED WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. Any statutory implied warranties, including any warranty of merchantability or fitness for a particular purpose, are expressly limited to the duration of this written warranty. Windsor will not be liable for any other damages, including but not limited to indirect or special consequential damages arising out of or in connection with the furnishing; performance, use or inability to use the machine. This remedy shall be the exclusive remedy of the buyer.
This warranty shall not apply to: 1
2.misuse or abuse(including the use of incompatible or corrosive chemicals or overloading of capacity): 3. failure due to lack of proper maintenance and care (including cleaning);
.damage in transit;
4.any design alterations performed by an organization not authorized or specified by Windsor;
5batteries and chargers. 6. high pressure washing.
7.electrical components exposed to moisture.
If difficulty develops during the warranty period, contact the authorized Windsor Agent from whom the product was purchased. Windsor, Inc. may elect to require the return of components to validate a claim. Any defective part to be returned must be shipped freight pre-paid to an authorized Windsor Distributor/Service Center or to the Windsor factory.
USE OF PARTS NOT APPROVED BY WINDSOR, INC. WILL VOID ALL WARRANTIES. This warranty is valid only for all products sold after July 1, 1995. A product sold before that date shall be covered by the limited Warranty in effect at the date of sale to the original purchaser.