Instruction/ maintenance manual of the product 10070090 Windsor
Go to page of 20
Read these instructions bef ore operating the machine MODEL: D100 10070090 86038260 – AA 07/09/08 PRV NO. 98636 CARPET EXTRACTOR Operating Instru ctions (ENG ).
MACHINE DATA LOG D100 86038260 05/21/07 2 For the name and address of your dealer contact: Windsor Industries YOUR DEALER Name: ____________________ ___________________________________ _______________.
TABLE OF CONTENTS D100 86038260 05/21/07 3 Machine Data Log ......................................... 2 Table of Contents .......................................... 3 HOW TO USE THIS MANUAL How to use this Manual. ................................ 1-1 SAFETY Important Safety Instructions .
HOW TO USE THIS MANUAL D100 86038260 05/21/07 1-1 This manual contains the f ollowin g sections: - HOW TO USE THIS MANUAL - SAFETY - OPERATIONS - MAINTENANCE - PARTS LIST The HOW TO USE THIS MANUAL section will tell you how to find important information for ordering correct repair parts.
SAFETY INSTRUCTIONS D100 86038260 05/21/07 2-1 IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precaution must always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE. This machine is for commercial use.
HAZARD INTENSITY LEVEL D100 86038260 05/21/07 2-2 The following symbols are used throughout this guide as indicated in their descriptions: HAZARD INTENSITY LEVEL There are three levels of hazard in tensity identified by signal words - WARNI NG and CAUTION and FOR SAFETY.
GROUNDING INSTRUCTIONS D100 86038260 05/21/07 2- 3 THIS PRODUCT IS FOR COMMERCIAL USE ONLY. ELECTRICAL: In the USA this machine operates on a standard 15 amp 115V, 60 hz, A.C. power circuit . The amp, hertz, and voltage are listed on the data label found on each machine.
TECHNICAL SPECIFICATIONS D100 86038260 05/21/07 3-1 ITEM DIMENSION/CAPACITY Electrical 115V, 60Hz, 15A Electric Vacuum Motor 2HP, 3 Stage Waterlift 137” (348 cm) Solution Pump 100 psi Solution Capacity 17 gallons (64.3 l) Recovery Capacity 15 gallons (56.
OPERATIONS D100 86038620 05/21/07 3- 2 CARPET INSPECTION: Determine precisely what areas you are going to clean. Note problem areas in the carpet or tack strip. Look for loose carpet, heavily damaged areas, discolored stains, or grease spots that will require prespotting.
MAINTENANCE D100 86038620 05/21/07 4-1 DAILY MAINTENANCE: (At the end of each working day) : 1) Flush the entire system, including floor tool, hand tool, etc., with 1 to 3 gallons of clean, hot water. 2) Vacuum out the solution tank . 3) Rinse tank with fresh water.
MAINTENANCE D100 86038260 05/21/07 4- 2 ! WARNING ONLY QUALIFIED MAINTENANCE PERSONNEL ARE TO PERFOR M THE FOLLOWING REPAIRS. VACUUM MOTOR REPLACEMENT 1. Turn off all switches and unplug machine. 2. Remove recovery tank. 3. Locate the vacuum motor wires and disconnect at the connector.
MAINTENANCE D100 86038260 05/21/07 4-3 ! WARNING: SOLUTION PUMP REPLACEMENT 1. Turn off all switches and unplug the machine. 2. Remove recovery tank. 3. Remove solution hoses from fittings in pump. 4. Remove the (2) screws that fasten the pump to the frame.
TROUBLESHOOTING D100 86038260 05/21/07 4- 4 PROBLEM . CAUSE SOLUTION No power to machine. Faulty power cord. Replace. Dead electrical circuit. Check building circuit breaker or fuse bo x. Electrical shock. Equipment not grounding. Follow grounding instructions exa ctly.
WIRING DIAGRAM D100 86038260 07/09/08 4-5.
MAINTENANCE D100 86038260 05/21/07 4- 6 SERVICE SCHEDULE MAINTENANCE DAILY WEEKLY QUARTERLY Check machine for cord damage * Check recovery dome an d gasket for damage and cleanliness * Check hose s f .
RECOVERY TANK ASSEMBLY D100 86038260 05/21/07 5-1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 14 15 16 17 22 23 12 23 24 18 19 20 21.
RECOVERY TANK ASSEMBLY D100 86038260 05/21/07 5- 2 REF PART NO. PRV NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1 86033260 05151 1 TUBE ASM, RECOVERY TANK 2 86242230 500009 1 LABEL, WARNING EXPLOSION H.
SOLUTION TANK ASSEMBLY D100 86038260 07/09/08 5-3 1 2 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 53A 31 17 9 30 33 30 31 9 42 36 37 38 40 39 41 42 43 44 45 46 47 48 49.
SOLUTION TANK ASSEMBLY D100 86038260 07/09/08 5- 4 REF PART NO. PRV NO. QTY DESCRIPTION SERIAL NO. FROM NOTES: 1 86002390 20063 1 CLAMP , 1.75” WORM GEAR X .
SUGGESTED SPARE PARTS D100 86038260 07/09/08 5-5 PART NO. PRV NO. DESCRIPTION SERIAL NO. FROM NOTES 86135320 140687 BRUSH SET, 120V VAC WINDSOR * 86135300 140676 BRUSH SET, 120V 3ST VAC AMETEK 8603164.
An important point after buying a device Windsor 10070090 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Windsor 10070090 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Windsor 10070090 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Windsor 10070090 you will learn all the available features of the product, as well as information on its operation. The information that you get Windsor 10070090 will certainly help you make a decision on the purchase.
If you already are a holder of Windsor 10070090, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Windsor 10070090.
However, one of the most important roles played by the user manual is to help in solving problems with Windsor 10070090. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Windsor 10070090 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center