Instruction/ maintenance manual of the product Model C Windsor
Go to page of 16
Handling, Installing and Operating Instructions Important Do not operate machine in unstable, low-flow range (surge). Read and become familiar with this manual prior to installing your Spencer Industravac equipment. Following the instructions detailed here will help you realize its full potential of efficient service and extended lifespan.
2 Contents Page I. W arranty 1 II. General Introduction 1 III. Getting Started 1 IV . Operation and Adjustments 7 V . Maintenance 7 Vl. T roubleshooting Guide — Separator 10 Vll.
3 Location Industravac vacuum producers are designed for operation at or near sea level atmospheric pressure and a nominal ambient temperature of 70°F (21°C).When necessary , they can be factory- designed for higher altitude or higher temperature operation.
4 Stationary Model. No special foundation is required. A level concrete floor or pad is recommended, although any other substantial floor is satisfactory .
Stationary Model Portable Model Stationary Model Portable Model 5 Series A Series B 2 1 / 4 cu. ft. DIRT CAN 2 1 / 4 cu. ft. DIRT CAN INLET EXHAUST DIFFUSER MANUAL BAG SHAKER 4" O.D. INLET INLET VA LV E MANUAL BAG SHAKER INLET V AL VE INLET V AL VE INLET V AL VE ST ARTER HANDLE 6" O.
6 Series C Series D Series V Stationary Model Portable Model INLET VA LV E MANUAL BAG SHAKER INLET INLET V AL VE INLET V AL VE INLET VA LV E 2-1/2 ” O.D. INLET MANUAL BAG SHAKER 2 1 / 4 cu. ft. DIRT CAN 2 1 / 4 cu. ft. DIRT CAN Stationary Model Stationary Model EXHAUST DIFFUSER ST ARTER HANDLE 4 1 / 3 cu.
7 V . Maintenance CAUTION: Disconnect electrical power before performing any maintenance procedure. 1. Lubrication 1. Motor . Follow motor manufacturer's recommendations. For following items 2 through 4, apply light lubricating oil yearly or more often as needed.
Reassembly (For Series V see Form ZZ) 1. Bolt the motor down tightly in its original position with the shaft in the exact center of the vacuum producer casing. Be sure that shims (if removed) are replaced in their exact positions on the same attach-points as before.
9 Balancing (For Series V see Form ZZ) T urn the machine on with inlet blocked to check balance. If there is excess vibration due to an unbalanced condition after reassemble, use the following balancing procedure: 1. Mark the position of the end impeller hub on the shaft.
10 Possible Cause • Worn or poorly fitting seals. • Holes worn in separator by abrasive materials. • Leaks. • Separator outlet blocked. • Dirt can liner sucked up against filter bag inlet. • Machine rotating backward. • Filter bags clogged.
11 Possible Cause VI. T roubleshooting Guide - V acuum Producer PROBLEM INSUFFICIENT AIR THROUGH SYSTEM MACHINE NOISY Corrective Action Change motor leads to correct rotation. Following instructions on pages 7-8, disassemble machine and reassemble correctly .
12 Possible Cause VI. T roubleshooting Guide - V acuum Producer (cont.) PROBLEM MACHINE VIBRA TING MOTOR HOT Corrective Action Clean impellers, check filter bags for holes. Straighten shaft. Replace bearing(s). Replace with correct motor . Disassemble machine, balance motor .
13 Filter Bag Part No. Filter Bag Maintenance Record Date Filter Bag Material Date Changed.
14 V acuum Accessories Record (Hoses, T ools, V alves) Part No. Description.
15 V acuum Cleaning Attachments and Accessories Catalog, Bulletin 241, contains Spencer ’s product line of professional cleaning components for use with portable and station- ary Industravac systems.
Industrially rated products offering effective solutions for air and gas moving problems: • Modular central vacuum systems • Mobile or stationary integrated vacuum units • Dust collectors and se.
An important point after buying a device Windsor Model C (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Windsor Model C yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Windsor Model C - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Windsor Model C you will learn all the available features of the product, as well as information on its operation. The information that you get Windsor Model C will certainly help you make a decision on the purchase.
If you already are a holder of Windsor Model C, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Windsor Model C.
However, one of the most important roles played by the user manual is to help in solving problems with Windsor Model C. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Windsor Model C along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center