50M56-743 Integrated Single or T wo-Stage HSI Integrated Furnace Control Kit INST ALLA TION INSTR UCTIONS DESCRIPTION The 50M56-743 kit is an automatic gas HSI Integrated Fur- nace Control that emplo ys a microprocessor to continually monitor , analyze, and control the proper oper ation of the gas burner , inducer , and fan.
2 SPECIFICA TIONS ELECTRICAL RA TINGS [@ 77°F (25°C)]: Input V oltage: 25 V AC 50/60 Hz Max. InputCurrent@25 V A C: 0.45 amp Rela y Load Ratings: V alve Rela y: 1.5 amp @ 25 V AC 50/60 Hz 0.6 pf Ignitor Rela y: 6.0 amp @ 120 V A C 50/60 Hz (resistive) Inducer Rela y: 2.
3 MOUNTING AND WIRING All wiring should be installed by a qualified heating and air conditioning contractor or licensed electrician, according to local and national electrical codes and ordinances.
4 WIRING TH TR MV HI MV COM MV LO GND HLO HLI PSO PSI C R G W Y Y W G R THERMOSTAT 2 STAGE GAS VALVE HIGH LIMIT (N. C.) ROLLOUT (N. C.) AUX. HIGH LIMIT (N.
5 50M56 TERMINAL TERMINAL TYPE SYSTEM COMPONENT CONNECTION TYPICAL SYSTEM WIRING TABLE † Maximum recommended flame probe wire length is 36 inches. low v oltage ther mostat W ter minal (or equivalent.
6 OPERA TION OPTION SWITCHES The option s witches on the 50M56-743 control are used to determine the length of the heat delay-to-f an-off per iod, the mode of operation, and the 2nd stage dela y per iod. The f ollowing illustration sho ws the options and the selections of the s witch positions.
7 SYSTEM LOCK OUT FEA TURES When system lock out occurs, the gas valv e is de-energized, the circulator blo wer is energized at heat speed, and, if flame is sensed, the inducer blo wer is energized. The diagnostic indicator light will flash or glow continuously to indicate system status.
HOMEO WNER HELP LINE :1-800-284-2925 White-Rodgers is a business of Emerson Electric Co. The Emerson logo is a trademark and ser vice mark of Emerson Electric Co.
An important point after buying a device White Rodgers 50M56-743 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought White Rodgers 50M56-743 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data White Rodgers 50M56-743 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, White Rodgers 50M56-743 you will learn all the available features of the product, as well as information on its operation. The information that you get White Rodgers 50M56-743 will certainly help you make a decision on the purchase.
If you already are a holder of White Rodgers 50M56-743, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime White Rodgers 50M56-743.
However, one of the most important roles played by the user manual is to help in solving problems with White Rodgers 50M56-743. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device White Rodgers 50M56-743 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center