FIRE HAZARD • Do not exceed the specified voltage. • Protect the control from direct contact with water (dripping, spraying, rain, etc.). • If the control has been in direct contact with water, replace the control. • Label all wires before disconnection when servic- ing controls.
2 SPECIFICA TIONS ELECTRICAL RATINGS [@ 77 ° F (25 ° C)]: Input Voltage: 25 VAC 50/60 Hz Max. Input Current @ 25 VAC: 0.45 amp Relay Load Ratings: Valve Relay: 1.5 amp @ 25 VAC 50/60 Hz 0.6 pf Ignitor Relay: 6.0 amp @ 120 VAC 50/60 Hz (resistive) Inducer Relay: 2.
3 INST ALLA TION MOUNTING AND WIRING All wiring should be installed according to local and national electrical codes and ordinances. The control must be secured to an area that will experience a minimum of vibration and remain below the maximum ambient temperature rating of 175 ° F.
4 TH TR MV MV GND FP HLO HLI PS C R G W Y EAC N HUM N XFMR N LINE N CIR N IGN IND IGN N IND N HUM EAC XFMR LINE PARK PARK HEAT COOL IGNITOR Y W G R THERMOSTAT GAS VALVE HIGH LIMIT (N.
5 50A55 TERMINAL TERMINAL TYPE SYSTEM COMPONENT CONNECTION TYPICAL SYSTEM WIRING TABLE W G R Y C TWIN* MV (2 terminals) TR TH RO1 RO2 FP PS HLI HLO GND (unused terminal) IND IGN IND N IGN N COOL HEAT .
6 OPERA TION OPTION SWITCHES The option switches on the 50A55-843 control are used to determine the length of the cool delay-to-fan-off, heat delay-to- fan-on and heat delay-to-fan-off periods. The following table shows the time periods that will result from the various switch positions.
7 TWINNING INTERF A CE If the control has six screw terminals, one of which is designated TWIN , the control is equipped with a single wire twinning interface. If twinning is used, either control will process a call for heat, cool or fan as described above.
MOUNTING HOLE TEMPLA TE FOR MOUNTING HOLE LOCA TIONS 4.172 ± .007 (2 plcs.) 6.402 ± .010 (2 plcs.) Refer to page 3 of the installation instructions for proper installation.
An important point after buying a device White Rodgers 50A55-843 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought White Rodgers 50A55-843 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data White Rodgers 50A55-843 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, White Rodgers 50A55-843 you will learn all the available features of the product, as well as information on its operation. The information that you get White Rodgers 50A55-843 will certainly help you make a decision on the purchase.
If you already are a holder of White Rodgers 50A55-843, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime White Rodgers 50A55-843.
However, one of the most important roles played by the user manual is to help in solving problems with White Rodgers 50A55-843. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device White Rodgers 50A55-843 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center