Instruction/ maintenance manual of the product 1F97W-71 White Rodgers
Go to page of 8
PART NO. 37-5091A 9139 Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.
2 SPECIFICA TIONS ELECTRICAL DATA Electrical Rating: 17 to 30v AC 50/60 Hz. 0.05 to 1.5 Amps 1.5 Amps Maximum Total Load (All terminals combined) Anticipation: Heating 2 to 40 Cooling 4 to 40 THERMAL .
3 REPLACEMENT INST ALLA TION REMOVE OLD THERMOSTAT 1. Shut off electricity at the main fuse box until installa- tion is complete. Verify power is off with a voltmeter. 2. Remove the front cover of the old thermostat. With wires still attached, remove wall plate from the wall.
4 All wiring diagrams are for typical systems only. Refer to equipment manufacturers' instructions for specific sys- tem wiring information. To prevent electrical shock and/or equipment damage, disconnect electrical power at the main fuse box or circuit breaker until installation is complete.
5 RH Y MV THERMOSTAT SYSTEM G W Figure 8. Typical Wiring Diagram for Millivolt Systems 6 Millivolt System RC G RC 6 MV Y W RH Thermostat Terminal Connections From millivolt system W From millivolt system MV RH Y MV THERMOSTAT SYSTEM G W Figure 9.
6 ATTACH THERMOSTAT TO SUBBASE IT IS RECOMMENDED THAT YOU SET OPTION SWITCHES TO DESIRED POSITION BEFORE ATTACH- ING ON SUBBASE (see OPERATION ). IT IS ALSO RECOMMENDED THAT YOU PROGRAM THE THERMOSTAT WITH BATTERIES INSTALLED BE- FORE ATTACHING ON SUBBASE (see OPERATION GUIDE for programming instructions) .
7 2. Manual Changeover (Heating/Cooling Systems Only) 3. Heat Only Systems 4. Cool Only Systems 5. Computed Energy Management Recovery (EMR) — With EMR enabled, system will be energized before the next program period begins, to achieve programmed temperature by the beginning of the next program period.
Refer to the OPERATION GUIDE if you need additional information on thermostat operation. TROUBLESHOOTING Refer to the Question & Answer section of the OPERA- TION GUIDE for information on troubleshooting the ther- mostat. If you need further information about this product, please write to: WHITE-RODGERS Division of Emerson Electric Co.
An important point after buying a device White Rodgers 1F97W-71 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought White Rodgers 1F97W-71 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data White Rodgers 1F97W-71 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, White Rodgers 1F97W-71 you will learn all the available features of the product, as well as information on its operation. The information that you get White Rodgers 1F97W-71 will certainly help you make a decision on the purchase.
If you already are a holder of White Rodgers 1F97W-71, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime White Rodgers 1F97W-71.
However, one of the most important roles played by the user manual is to help in solving problems with White Rodgers 1F97W-71. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device White Rodgers 1F97W-71 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center