Table of Contents 80 sections Installation and Operation Manual · Model WHELJ1 · Whirlpool Gold ® · Central Water Filtration System · … ShowHide
Installation and Operation Manualp.1Model WHELJ1p.1Whirlpool Gold ®p.1Central Water Filtration Systemp.1How to install, operate and maintain your Centralp.1Water Filtration Systemp.11-866-986-3223 MondayFriday, 8 AM-9PM ESTp.1TABLE OF CONTENTSp.2Questions?p.2Central Water Filtration System Safetyp.3Before You Startp.3Inspect Shipmentp.4Packing Listp.4Central Water Filtration System Dimensionsp.5INp.5OUTp.5TOP VIEWp.5IN - OUTp.5SIDE VIEW FRONT VIEWp.5Model No. _____________________________ Code ________________________p.5Serial No. _____________________________ Installation Date _______________p.5How a Central Water Filtration System Worksp.6NORMAL OPERATIONp.6APPLICATIONS FOR A CENTRAL WATER FILTRATION SYSTEMp.6CLEAN RINSE CYCLEp.6Installation Requirementsp.7TOOLS NEEDEDp.7LOCATION REQUIREMENTSp.7THE PROPER ORDER TO INSTALL WATER TREATMENT EQUIPMENTp.7ORp.7AIR GAP REQUIREMENTSp.8VALVE DRAIN REQUIREMENTSp.8CONNECTING VALVE TO DRAINp.8SUBSTITUTING RIGID DRAIN LINEp.8LAUNDRY TUB STANDPIPEp.8FLOOR DRAINp.8Plan the Installationp.9INLET - OUTLET PLUMBING OPTIONSp.93 VALVE BYPASSp.9CONNECTING PLUMBING TO VALVEp.9IN OUTp.9CROSS OVERp.9In what direction does the water flow?p.9Installationp.10TURN OFF WATER SUPPLYp.10LEVEL IF NECESSARYp.10MOVE THE CENTRAL WATER FILTRATION SYSTEM INTO PLACEp.10REMOVE TOP COVER AND HANG IT FROM POST ON FRONT OF RIMp.10ASSEMBLE INLET AND OUTLET PLUMBINGp.10CONNECT INLET AND OUTLET PLUMBINGp.11Soldered Copperp.11Threaded Pipep.11CPVC Plastic Pipep.11Other, including PEX (Crosslinked Polyethylene)p.11INSTALL VALVE DRAIN HOSEp.12SINGLE BYPASS VALVEp.12TEST FOR LEAKSp.12TURN ON THE CENTRAL WATER FILTRATION SYSTEMp.12Start Up Procedurep.13IMPORTANT:p.13During the start up cycle:p.13After the start up cycle:p.13To Initiate the start up cycle:p.13Programming the Central Water Filtration Systemp.14CLEANp.14SET TIME OF DAYp.14Customizing Features / Optionsp.15START A CLEAN RINSE CYCLEp.15SET NUMBER OF DAYS BETWEEN CLEAN RINSE CYCLESp.15SET CLEAN RINSE TIMEp.15SET LENGTH OF CLEAN RINSEp.15OPERATING IN MANUAL CLEAN RINSE MODEp.16DISABLING AUTOMATIC CLEAN RINSEp.16MANUALLY STARTING AN CLEAN RINSE CYCLEp.16RE-ENABLING AUTOMATIC CLEAN RINSEp.16POWER OUTAGE MEMORYp.16Care of Your Central Water Filtration Systemp.17VACATIONS AND EXTENDED PERIODS OF NO WATER USEp.17PROTECT THE CENTRAL WATER FILTRATION SYSTEM FROM FREEZINGp.17DRAIN ALL WATER FROM CENTRAL WATER FILTRATION SYSTEMp.17
Page 1 of the Whirlpool WHELJ1 user manual — 1-866-986-3223 MondayFriday, 8 AM-9PM EST
Page 1 · click to enlarge
Page 1

Installation and Operation Manual

Whirlpool WHELJ1 — Installation and Operation Manual diagram (page 1)
Fig. 1 · Installation and Operation Manual

Model WHELJ1

Whirlpool Gold ®

Central Water Filtration System

How to install, operate and maintain your Central

Water Filtration System

If you have any questions or concerns when

installing, operating or maintaining your

Central Water Filtration System

call our toll free number:

1-866-986-3223 MondayFriday, 8 AM-9PM EST

or visit www.whirlpool.com

System tested and certified by NSF International

against NSF/ANSI Standard 42. See performance data sheet for details.

Manufactured and warranted by

Ecodyne Water Systems LLC

1890 Woodlane Drive Woodbury, MN 55125

7290541 (Rev. C 11/14/06) Product No. W10114885

Page 2 of the Whirlpool WHELJ1 user manual — Table of Contents
Page 2 · Contents
Contents

Contents

Installation and Operation Manualp.1Model WHELJ1p.1Whirlpool Gold ®p.1Central Water Filtration Systemp.1How to install, operate and maintain your Centralp.1Water Filtration Systemp.11-866-986-3223 MondayFriday, 8 AM-9PM ESTp.1TABLE OF CONTENTSp.2Questions?p.2Central Water Filtration System Safetyp.3Before You Startp.3Inspect Shipmentp.4Packing Listp.4Central Water Filtration System Dimensionsp.5INp.5OUTp.5TOP VIEWp.5IN - OUTp.5SIDE VIEW FRONT VIEWp.5Model No. _____________________________ Code ________________________p.5Serial No. _____________________________ Installation Date _______________p.5How a Central Water Filtration System Worksp.6NORMAL OPERATIONp.6APPLICATIONS FOR A CENTRAL WATER FILTRATION SYSTEMp.6CLEAN RINSE CYCLEp.6Installation Requirementsp.7TOOLS NEEDEDp.7LOCATION REQUIREMENTSp.7THE PROPER ORDER TO INSTALL WATER TREATMENT EQUIPMENTp.7ORp.7AIR GAP REQUIREMENTSp.8VALVE DRAIN REQUIREMENTSp.8CONNECTING VALVE TO DRAINp.8SUBSTITUTING RIGID DRAIN LINEp.8LAUNDRY TUB STANDPIPEp.8FLOOR DRAINp.8Plan the Installationp.9INLET - OUTLET PLUMBING OPTIONSp.93 VALVE BYPASSp.9CONNECTING PLUMBING TO VALVEp.9IN OUTp.9CROSS OVERp.9In what direction does the water flow?p.9Installationp.10TURN OFF WATER SUPPLYp.10LEVEL IF NECESSARYp.10MOVE THE CENTRAL WATER FILTRATION SYSTEM INTO PLACEp.10REMOVE TOP COVER AND HANG IT FROM POST ON FRONT OF RIMp.10ASSEMBLE INLET AND OUTLET PLUMBINGp.10CONNECT INLET AND OUTLET PLUMBINGp.11Soldered Copperp.11Threaded Pipep.11CPVC Plastic Pipep.11Other, including PEX (Crosslinked Polyethylene)p.11INSTALL VALVE DRAIN HOSEp.12SINGLE BYPASS VALVEp.12TEST FOR LEAKSp.12TURN ON THE CENTRAL WATER FILTRATION SYSTEMp.12Start Up Procedurep.13IMPORTANT:p.13During the start up cycle:p.13After the start up cycle:p.13To Initiate the start up cycle:p.13Programming the Central Water Filtration Systemp.14CLEANp.14SET TIME OF DAYp.14Customizing Features / Optionsp.15START A CLEAN RINSE CYCLEp.15SET NUMBER OF DAYS BETWEEN CLEAN RINSE CYCLESp.15SET CLEAN RINSE TIMEp.15SET LENGTH OF CLEAN RINSEp.15OPERATING IN MANUAL CLEAN RINSE MODEp.16DISABLING AUTOMATIC CLEAN RINSEp.16MANUALLY STARTING AN CLEAN RINSE CYCLEp.16RE-ENABLING AUTOMATIC CLEAN RINSEp.16POWER OUTAGE MEMORYp.16Care of Your Central Water Filtration Systemp.17VACATIONS AND EXTENDED PERIODS OF NO WATER USEp.17PROTECT THE CENTRAL WATER FILTRATION SYSTEM FROM FREEZINGp.17DRAIN ALL WATER FROM CENTRAL WATER FILTRATION SYSTEMp.17
Page 3 of the Whirlpool WHELJ1 user manual — Before You Start
Page 3 · click to enlarge
Page 3

Central Water Filtration System Safety

Your safety and the safety of others are very important.

We have provided many safety messages in this manual and on your appliance. Always read and obey all safety messages.

This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING” These words mean:

You can be killed or seriously injured if you don’t immediately follow instructions.

You can be killed or seriously injured if you don’t follow instructions.

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.

The Commonwealth of Massachusetts plumbing code 248-CMR shall be adhered to. A licensed plumber shall be used for this installation.

Before You Start

See "Installation Requirements" section before installing Central Water Filtration System.

Follow the installation instructions (Failure to install the system properly voids the warranty).

Before you begin installation, read this entire manual. Then, obtain all the materials and tools you will need to

make the installation. Check local plumbing and electrical codes.

Use only lead-free solder and flux for all sweat-solder connections, as required by federal codes.

Use care when handling the Central Water Filtration System. Do not turn upside down, drop, or set on sharp pro-

trusions.

Avoid installing in direct sunlight. Excessive sun heat may cause distortion or other damage to non-metallic parts.

The Central Water Filtration System has a maximum allowable inlet water pressure of 125 psi and a minimum of

30 psi. If daytime pressure is over 80 psi, nighttime pressure may exceed the maximum. Use a pressure reduc- ing valve if necessary (Adding a pressure reducing valve may reduce the flow.). If your home is equipped with a back flow preventer, an expansion tank must be installed in accordance with local codes and laws.

The Central Water Filtration System works on 24 volt, 60 Hz electrical power only, supplied by a direct plug-in

transformer (included). Be sure to use the included transformer and plug it into a nominal 120V, 60 cycle house- hold outlet that is properly protected by an overcurrent device such as a circuit breaker or fuse. If transformer is replaced, use only the authorized service, Class II, 24V 10VA transformer.

Do not use the Central Water Filtration System with water that is microbiologically unsafe or of unknown quality

without adequate disinfection before or after the system.

European Directive 2002/96/EC requires all electrical and electronic equipment to be disposed of accord- ing to Waste Electrical and Electronic Equipment (WEEE) requirements. This directive or similar laws are in place nationally and can vary from region to region. Please refer to your state and local laws for proper disposal of this equipment.

Page 4 of the Whirlpool WHELJ1 user manual — Packing List
Page 4 · click to enlarge
Page 4

Inspect Shipment

The parts required to assemble and install the Central Water Filtration System are included with the unit.

Remove and discard (or recycle) all packing materials. To avoid loss of small parts, we suggest you keep the small parts in the parts bag until you are ready to use them.

Thoroughly check the Central Water Filtration System for possible shipping damage and parts loss. Also inspect and note any damage to the shipping carton.

Packing List

Ground Clamp Kit Bypass Valve 10 ft. Drain Hose

Clips Adaptor Elbow Installation Adaptors

Do not return the Central Water Filtration System to store.

If you have any questions, or there are missing parts or damage, please call Toll Free 1-866-986-3223, Monday - Friday, 8 am - 9 pm EST.

Before you call please have your model number, and date of purchase ready.

Hose Clamps

Page 5 of the Whirlpool WHELJ1 user manual — Model No. _____________________________ Code ________________________
Page 5 · click to enlarge
Page 5

Central Water Filtration System Dimensions

IN

OUT

TOP VIEW

IN - OUT

SIDE VIEW FRONT VIEW

For future reference, enter the following information.

Model No Code

Serial No. _____________________________ Installation Date _______________

Model No. and Serial No. are on the shipping carton and on the registration decal on the Central Water Filtration System. Code is on the registration decal.

Show 5 more labels / short text on this page
10-1/8" · 3-3/8" · 13-7/16" · 33-3/4" · 27-1/2"
Page 6 of the Whirlpool WHELJ1 user manual — CLEAN RINSE CYCLE
Page 6 · click to enlarge
Page 6

How a Central Water Filtration System Works

NORMAL OPERATION

APPLICATIONS FOR A CENTRAL WATER FILTRATION SYSTEM

During normal operation water enters the Central Water Filtration System and flows through several fil- tration processes where tastes, odors and sediment* are reduced.

Do not use the Central Water Filtration System with

water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

The Central Water Filtration System may not be an

CLEAN RINSE CYCLE

effective treatment method for water sources with a hydrogen sulfide problem (rotten egg odor or taste) If your water has hydrogen sulfide, contact a water treatment expert or call 1-866-986-3223.

A Clean Rinse cycle will automatically be initiated based on how the controller has been programmed. The Clean Rinse cycle lifts and expands the media bed to rejuvenate the media and then repacks the bed for continued use. During the Clean Rinse cycle, dirt, sediment, iron, etc. are flushed from the Central Water Filtration System down the drain.

The Central Water Filtration System will not remove

iron and is not intended to replace iron treatment equipment.

Although the Central Water Filtration System has

sediment* filter capabilities, additional sediment fil- tration may be needed in problem water applica- tions.

* As shown by independent third party test data.

Page 7 of the Whirlpool WHELJ1 user manual — THE PROPER ORDER TO INSTALL WATER TREATMENT EQUIPMENT
Page 7 · click to enlarge
Page 7

Installation Requirements

TOOLS NEEDED

LOCATION REQUIREMENTS

Assemble the required tools before starting installation. Read and follow instructions provided with any tools listed here.

Consider the following when selecting an installation location for the Central Water Filtration System.

Do not operate the Central Water Filtration System

Screwdriver Tape measure Pliers

where freezing temperatures occur. Do not attempt to treat water over 120ºF. Freezing temperatures or hot water damage voids the warranty.

To condition all water in the home, install the

If using Soldered Copper Pipe

Central Water Filtration System close to the water supply inlet, and before all other plumbing connec- tions, except outside water pipes.

Tubing cutter Lead-free solder and flux Propane torch Emery cloth, sandpaper or steel wool Misc. copper pipe fittings

A nearby drain is needed to carry away Clean

Rinse discharge water. Use a floor drain, laundry tub, sump, standpipe, or other options (check your local codes). See "Air Gap Requirements" and "Valve Drain Requirements" sections. If a drain is not available, it is still possible to operate the Central Water Filtration System in a manual Clean Rinse mode. See “Operating in Manual Clean Rinse Mode.” The automatic Clean Rinse must be disabled if the Central Water Filtration System will not be connected to a drain (See Page 8).

If using Threaded Pipe

Pipe cutter or hacksaw Pipe joint compound Threading tool Misc. threaded pipe fittings

If using CPVC Plastic

Pipe cutter Solvent cement Hacksaw Primer Adjustable wrench

The Central Water Filtration System works on

24 volt, 60 Hz electrical power only, supplied by a direct plug-in transformer (included). Provide an electrical outlet in accordance with NEC and local codes.

Do not install the Central Water Filtration System

on a hot water line (See Figure 3 below).

Other pipe and fittings suitable for potable water as

Install the Central Water Filtration System between

required by piping system manufacturer and local codes and/or ordinances.

the home’s incoming water supply and the water softener, if one is being used (See Figure 3).

THE PROPER ORDER TO INSTALL WATER TREATMENT EQUIPMENT

OR

Show 19 more labels / short text on this page
If using Other · Untreated Water to · City Water Supply · Outside Faucets · Cold Water · to House · Hot Water · Pressure · to House · Optional Sediment · Tank · Filter · Water Heater · Water Softener · Central · Well Water Supply · Water Filtration · Well Pump · System
Page 8 of the Whirlpool WHELJ1 user manual — FLOOR DRAIN
Page 8 · click to enlarge
Page 8

Installation Requirements

AIR GAP REQUIREMENTS

VALVE DRAIN REQUIREMENTS

A drain is needed for Clean Rinse discharge water. A floor drain, close to the Central Water Filtration System, is preferred. A laundry tub, standpipe, etc. are other drain options. Secure valve drain hose in place. Leave an air gap of 1-1/2” between the end of the hose and the drain. This gap is needed to prevent backflow of sewer water into the Central Water Filtration System . Do not put the end of the drain hose into the drain.

Using the flexible drain hose (included), measure and cut to the length needed. Flexible drain hose is not allowed in all localities (check your plumbing codes). If local codes do not allow use of a flexible drain hose, a rigid valve drain run must be used. Purchase a com- pression fitting (1/4 NPT x 1/2 in. minimum tube) and 1/2" tubing from your local hardware store. Plumb a rigid drain as needed (see Figure 4, below).

Make the valve drain line as short and direct as possible.

It is recommended that the Central Water Filtration System be installed near a drain. However, if a drain is not available, it is still possible to operate the Central Water Filtration System in.a manual Clean Rinse mode. See “Operating in Manual Clean Rinse Mode” section. The automatic Clean Rinse function must be disabled if the Central Water Filtration System will not be connected to a drain.

The Commonwealth of Massachusetts plumbing code 248-CMR shall be adhered to. A licensed plumber shall be used for this installation.

CONNECTING VALVE TO DRAIN

SUBSTITUTING RIGID DRAIN LINE

Whirlpool WHELJ1 — CONNECTING VALVE TO DRAIN diagram (page 8)
Fig. 2

1/2” Outside Dia. Copper Tube (not included)

Cut barbs from drain fitting (pull clip to remove fit-

To drain point other

than floor drain. Support tubing in place as needed.

Comp Fitting. 1/4

NPT x 1/2” O.D. Tube (not included)

Install adaptor elbow using hose

clamp. Aim noz-

center of drain Tie or wire

LAUNDRY TUB STANDPIPE

Drain grate with 1”

dia. hole in center

FLOOR DRAIN

Show 14 more labels / short text on this page
Drain Fitting · 1/4 NPT Threads · Barbs · Hose Clamp · Clip · ting from valve) · Valve Drain · Hose · 1-1/2” air gap · zle down toward · 1-1/2” air gap · tubing in · 1-1/2” air gap · place
Page 9 of the Whirlpool WHELJ1 user manual — IN OUT
Page 9 · click to enlarge
Page 9

Plan the Installation

INLET - OUTLET PLUMBING OPTIONS

3 VALVE BYPASS

Always install either a single bypass valve (provided) or, if desired, parts for a 3 valve bypass system (not included) can be purchased and assembled, as shown in Figure 6. Bypass valves allow you to turn off water to the Central Water Filtration System for maintenance if needed, but still have water in house pipes.

Use either:

Copper pipe Threaded pipe PEX (Crosslinked Polyethylene) pipe CPVC plastic pipe Other pipe approved for use with potable water

installation adapters and single valve bypass. Soldering heat will damage the adapters and valve.

CONNECTING PLUMBING TO VALVE

IN OUT

1” NPT Sweat Adapter (2) (not included) Use teflon tape,

CROSS OVER

In what direction does the water flow?

Be sure to plan piping so water flow is to the Central Water Filtration System valve INLET. Plan a crossover if flow is from left to right.

2 of each included

Bypass Valve Valve Inlet

IN OUT

Untreated Water to Valve INLET

1” NPT Sweat Adapter (2) (not included)

2 of each included

To Central Water Filtration System

Show 17 more labels / short text on this page
Central Water Filtration · System OUTLET · Central Water Filtration · System INLET · pipe joint com- · pound or both · 1” NPT Adapter · Clip · Main Water Pipe · Use teflon tape, · pipe joint com- · Treated Water from · pound or both · Valve OUTLET · Clip · 1” NPT Adapter · Valve Inlet
Page 10 of the Whirlpool WHELJ1 user manual — ASSEMBLE INLET AND OUTLET PLUMBING
Page 10 · click to enlarge
Page 10

Installation

TURN OFF WATER SUPPLY

LEVEL IF NECESSARY

1. Close the main water supply valve, near the well pump or water meter.
2. Open all faucets to drain water from the house pipes.

heater, as damage to the water heater ele- ments could result.

MOVE THE CENTRAL WATER FILTRATION SYSTEM INTO PLACE

Use two or more people to move and install Central Water Filtration System.

Failure to do so can result in back or other injury.

1. Move the Central Water Filtration System into installation position. Set it on a level surface. If needed, place the unit on a section of plywood, a minimum of 5/8” thick. Then place shims under the plywood to level the Central Water Filtration System (see Figure 8).

REMOVE TOP COVER AND HANG IT FROM POST ON FRONT OF RIM

2. Remove top cover.
3. Hang cover from post on front of rim, as shown in Figure 9. Avoid allowing cover to hang from wires.

ASSEMBLE INLET AND OUTLET PLUMBING

Measure, cut, and loosely assemble pipe and fittings from the main water pipe to the inlet and outlet ports of the Central Water Filtration System valve. Be sure to keep fittings fully together, and pipes squared and straight. Be sure incoming water supply pipe goes to the Central Water Filtration System valve INLET side.

Trace the water flow direction to be sure.

plumbing to prevent putting stress on the Central Water Filtration System valve inlet and outlet. Undue stress from misaligned or unsupported plumb- ing may cause damage to the valve.

Show 4 more labels / short text on this page
Excessive Weight Hazard · Plywood Shim(s) · Post · Top Cover
Page 11 of the Whirlpool WHELJ1 user manual — Other, including PEX (Crosslinked Polyethylene)
Page 11 · click to enlarge
Page 11

Installation

CONNECT INLET AND OUTLET PLUMBING

ATTACH GROUND CLAMP TO PIPES IF THE INSTALLATION USES METAL PIPES AND PLASTIC BYPASS VALVE

Complete the inlet and outlet plumbing for the type of pipe as shown below.

Soldered Copper

1. Thoroughly clean and apply solder flux to all joints.

Screw with lock washer

2. Make all solder connections.

installation Adapters and single valve bypass. Soldering heat will damage the Adapters and valve.

3. Secure ground clamp to metal pipes.

Threaded Pipe

1. Apply pipe joint compound or Teflon® tape to all male pipe threads.
2. Tighten all threaded joints and make all solder connections.

Use metal fittings with metal pipe.

Do not use plastic fittings to connect to metal house pipes.

Failure to follow these instructions can result in death or electrical shock.

3. Secure ground clamp to metal pipes.

CPVC Plastic Pipe

1. Clean, prime and cement all joints, following the manufacturer's instructions supplied with the plastic pipe and fittings.

Other, including PEX (Crosslinked Polyethylene)

1. Follow the piping system manufacturer's instructions when using other pipe approved for potable water.
2. Secure ground clamp to metal pipes.

® Teflon is a registered trademark of E.I. Du Pont de

Nemours and Company.

Show 5 more labels / short text on this page
Ground Clamp (2) · Metal Pipes · & nut · Plastic Bypass Valve · Electrical Shock Hazard
Page 12 of the Whirlpool WHELJ1 user manual — TURN ON THE CENTRAL WATER FILTRATION SYSTEM
Page 12 · click to enlarge
Page 12

Installation

INSTALL VALVE DRAIN HOSE

SINGLE BYPASS VALVE

1. Measure, cut to needed length and connect the 3/8" drain line (provided) to the Central Water Filtration System valve drain fitting. Use a hose clamp to hold the hose in place.

Pull handle OUT for normal

Drain requirements" section.

2. Run the drain hose or copper tubing to the floor drain. Secure drain hose. This will prevent the drain line from “whipping'' during Clean Rinse cycles. See “Air Gap Requirements" section.

TEST FOR LEAKS

1. Place the single bypass valve (or 3 valve bypass, if installed) in normal operation (non-"bypass") position. See "Plan The Installation" section.
2. Fully open the main water supply valve.
3. Check for leaks at all the plumbing connections you made.

using any filtered water. Follow the instructions below and on Page 13.

TURN ON THE CENTRAL WATER FILTRATION SYSTEM

During installation, the Central Water Filtration System wiring may be moved or jostled from place. Check to be sure all leadwire connectors are secure on the back of the electronic board (see Figure 27 on Page 21) and be sure all wiring is away from the valve gear and motor area, which rotates during Clean Rinse cycles.

1. Plug the Central Water Filtration System into an electrical outlet that is not controlled by a switch.
2. The display should begin flashing 12:00 PM and “PRESENT TIME.” Set the clock according to the “Set Time of Day” section on Page 14.
3. Run the start up procedure, as detailed on Page 13.

operation · Push handle IN · for BYPASS

Page 13 of the Whirlpool WHELJ1 user manual — To Initiate the start up cycle:
Page 13 · click to enlarge
Page 13

Start Up Procedure

IMPORTANT:

During the start up cycle:

The filtration media in this Central Water Filtration System contains a small number of particles generated during manufacturing and shipping that are small enough to exit the system with water flow. It is normal for these particles to cause a temporary discoloration of the water coming out of the system. To avoid dis- colored water at your home’s faucets the system’s start up cycle should be initiated to rinse the particles and any discolored water down the drain.

Throughout the start up cycle you will hear the valve changing position and notice the flow of water to drain starting and stopping. The start up cycle will take approximately 20 minutes. Avoid using water during this time. Do not set the time of day or press other buttons during the start up cycle, as this will interrupt it. Do not unplug the transformer during the start up cycle. If the start up cycle is interrupted, it should be initiated again and allowed to run to completion.

If the Central Water Filtration System is used without first running the start up cycle, you will notice that the water will temporarily have a gray color until the parti- cles have exited the system.

After the start up cycle:

Once the start up procedure completes successfully, it cannot be initiated a second time. The Central Water Filtration System will automatically return to the normal operation position and be ready for use. If, after run- ning the start up cycle, the water still appears discol- ored, manually run Clean Rinse cycles (See Page 15) until the water is clear.

To Initiate the start up cycle:

1. Make sure the drain hose is attached to the Central Water Filtration System and the other end is secured over a drain (see “Install Valve Drain Hose”).

If the time of day was not set before the start up cycle, set it now (See Page 14).

2. Make sure bypass valve is in the “service” (open or filtered water) position and the home’s water supply is turned on.

Check the new plumbing connections and joints once more for leaks.

3. Press and hold the CLEAN button to initiate the start up cycle. The button can be released when you hear the valve changing position and “RECHARGE NOW” flashes in the display.
Page 14 of the Whirlpool WHELJ1 user manual — SET TIME OF DAY
Page 14 · click to enlarge
Page 14

Programming the Central Water Filtration System

CLEAN

If you have questions about installation, program- ming, operating and routine maintenance...

call 1-866-986-3223, Monday - Friday, 8 am to 9 pm, EST.

When the transformer is plugged into the electrical outlet, a model code and a test number (example: J1.3), begin to flash in the faceplate display. Then, 12:00 PM and the words “PRESENT TIME" begin to flash.

DOWN button until “CF 8” shows in the dis- play. Then, press the PROGRAM button to set, and change to the flashing “PRESENT TIME" dis- play.

SET TIME OF DAY

If the words “PRESENT TIME" do not show in the display, press the PROGRAM button until they do.

1. Press the UP or DOWN buttons to set the present time. Up moves the display ahead; down sets the time back. Be sure AM or PM is correct.

advance the display. Hold the buttons down for fast advance.

2. Press the PROGRAM button a few times, until the time appears on the display, but is not flashing.
Show 5 more labels / short text on this page
Display · UP button · DOWN button · PROGRAM button · button
Page 15 of the Whirlpool WHELJ1 user manual — SET LENGTH OF CLEAN RINSE
Page 15 · click to enlarge
Page 15

Customizing Features / Options

START A CLEAN RINSE CYCLE

To manually start a Clean Rinse cycle, press and hold the CLEAN button for a few seconds, until “RECHARGE NOW” flashes in the display.

SET NUMBER OF DAYS BETWEEN CLEAN RINSE CYCLES

By default the Central Water Filtration System will automatically initiate a Clean Rinse every 14 days. This should be sufficient for most applica- tions. To change the number of days between Clean Rinse cycles: 1. Press the PROGRAM button until “RECHARGE” is shown in the dis- play.

2. Press the UP or DOWN buttons to set the number of days between Clean Rinse cycles (from 1 to 99). 3. Press the PROGRAM button again when complete.

SET CLEAN RINSE TIME

By default the Central Water Filtration System will Clean Rinse at 1:00 a.m. To change the Clean Rinse start time: 1. Press the PROGRAM button until “RECHARGE TIME” is shown in the display.

2. Press the UP or DOWN buttons to set the Clean Rinse time. Be sure AM or PM is correct. 3. Press the PROGRAM button again when complete.

SET LENGTH OF CLEAN RINSE

By default the Central Water Filtration System’s Clean Rinse cycle will consist of a 2 minute backwash followed by a 1 minute fast rinse. This should be sufficient for most applications. Increasing the length of Clean Rinse time will increase the amount of water flushed to drain during each Clean Rinse cycle, therefore, these times should only be increased when necessary. To change the length of the backwash part of the Clean Rinse cycle: 1. Press and hold the PROGRAM button for a few seconds, until the “000--” screen appears, as shown at right. 2. Press the PROGRAM button once, so “bA TIME” appears in the dis- play.

3. Press the UP or DOWN buttons to set the length of backwash in minutes. 4. Press the PROGRAM button again when complete. To change the length of the fast rinse part of the Clean Rinse cycle: 1. Press and hold the PROGRAM button for a few seconds, until the “000--” screen appears, as shown at right. 2. Press the PROGRAM button once, so “Fr TIME” appears in the display.
3. Press the UP or DOWN buttons to set the length of fast rinse in minutes. 4. Press the PROGRAM button again when complete.
Page 16 of the Whirlpool WHELJ1 user manual — POWER OUTAGE MEMORY
Page 16 · click to enlarge
Page 16

Customizing Features / Options

OPERATING IN MANUAL CLEAN RINSE MODE

Clean Rinse cycles will run automatically, unless the automatic Clean Rinse function has been disabled. If this function has been disabled, it will be necessary to manually initiate any Clean Rinse cycles. It is recommended that a Clean Rinse cycle should be run at least once each month, or more frequently if necessary.

A manual Clean Rinse mode may be used when a drain (required for automatic Clean Rinse) is not available. However, it is recommended that automatic Clean Rinse be used if the drain requirements can be met.

DISABLING AUTOMATIC CLEAN RINSE

To disable the automatic Clean Rinse function:

1. Press and immediately release the CLEAN button (pressing and holding the button a few seconds would initiate a Clean Rinse cycle).
2. “VAC” should flash in the display, as shown in Figure 19, indicating that the Central Water Filtration System is in the manual Clean Rinse mode (the automatic Clean Rinse function has been disabled).

MANUALLY STARTING AN CLEAN RINSE CYCLE

To manually start an Clean Rinse cycle:

1. Press and hold the CLEAN button for a few seconds, until “RECHARGE NOW” flashes in the display.
2. When the Clean Rinse cycle is complete, the Central Water Filtration System will remain in the manual Clean Rinse mode.

RE-ENABLING AUTOMATIC CLEAN RINSE

To return the Central Water Filtration System to its automatic Clean Rinse function:

1. Press and immediately release the CLEAN button.
2. The flashing “VAC” on the display should be replaced by the normal time of day screen, as shown in Figure 21.

POWER OUTAGE MEMORY

If electrical power to the Central Water Filtration System is lost, “mem- ory'' built into the controller circuitry will keep all settings for up to eight hours. While the power is out, the display is blank and the Central Water Filtration System will not Clean Rinse.

When electrical power is restored, you have to reset the time of day only if the display is flashing. The Clean Rinse TIME never requires resetting unless a change is desired. Even if the clock is incorrect after a long power outage, the Central Water Filtration System works as it should to keep your water treated. However, Clean Rinse cycles may occur at the wrong time of day until you reset the clock to the correct time of day.

cycle when power was lost, it will now finish the cycle.

Page 17 of the Whirlpool WHELJ1 user manual — DRAIN ALL WATER FROM CENTRAL WATER FILTRATION SYSTEM
Page 17 · click to enlarge
Page 17

Care of Your Central Water Filtration System

VACATIONS AND EXTENDED PERIODS OF NO WATER USE

PROTECT THE CENTRAL WATER FILTRATION SYSTEM FROM FREEZING

If the Central Water Filtration System is installed where it could freeze (summer cabin, lake home, etc.), you must drain all water from it to stop possible freeze damage. To drain the unit:

If your Central Water Filtration System will not be used for an extended period of time (several months), please follow one of these recommendations:

If the water supply to the unit is not turned off, and

1. Close the shut-off valve on the house main water pipe, near the water meter or pressure tank.

the automatic Clean Rinse function has not been disabled, then no further actions are required.

2. Open a faucet in the filtered water pipes to vent pressure in the unit.

If the Clean Rinse cycle cannot be automatically

run, due to the water supply being shut off, the transformer being unplugged or the automatic Clean Rinse function being disabled, then it is rec- ommended that a minimum of 2 manually initiated Clean Rinse cycles be performed when the system is placed back into operation (see Start a Clean Rinse Cycle section on Page 15).

3. Move the stem in the single bypass valve to bypass. Close the inlet and outlet valve in a 3 valve bypass system, and open the bypass valve. If you want water in the house pipes again, reopen the shut-off valve on the main water pipe.
4. Unplug the transformer at the wall outlet. Remove the cover. Take off the drain hose if it will interfere with moving the Central Water Filtration System into position over the drain.

In any installation where there is a possibility of

freezing, the Central Water Filtration System should be disconnected and the water drained (see Protect the Central Water Filtration System from Freezing section).

5. Remove the large holding clips at the Central Water Filtration System inlet and outlet. Separate the unit from the plastic installation adaptors, or from the bypass valve.
6. Lay a piece of 2 inch thick board near the floor drain.

Use two or more people to move and install Central Water Filtration System.

DRAIN ALL WATER FROM CENTRAL WATER FILTRATION SYSTEM

Failure to do so can result in back or other injury.

7. Move the Central Water Filtration System close to the drain. Slowly and gently, tip it over until the rim rests on the wood block with the inlet and outlet over the drain. Do not allow the unit’s weight to rest on the inlet and outlet fittings or they may break.
8. Tip the bottom of the Central Water Filtration System up a few inches and hold until all water has drained. Leave the unit laying like this until you are ready to use it. Plug the inlet and outlet with clean rags to keep dirt, bugs, etc. out.

Excessive Weight Hazard · Wood Block · Floor Drain

Page 18 of the Whirlpool WHELJ1 user manual — PROBLEM CAUSE CORRECTION
Page 18 · click to enlarge
Page 18

Troubleshooting

PROBLEM CAUSE CORRECTION

Water has black or gray color

(NEW SYSTEM) Start up procedure has not been completed

Run start up procedure (See Page 13) or run consecutive Clean Rinse cycles (See Page 15) until water color returns to nor- mal.

(NOT A NEW SYSTEM) Normal abra- sion of filtration media

Manually initiate a Clean Rinse cycle (See Page 15).

Low water pressure at house faucets

Sediment filter screen is clogged Manually initiate a Clean Rinse cycle (See Page 15).

Clean sediment filter screen (See Page 20). If the filter screen is frequently plug- ging, it may be necessary to adjust the frequency of Clean Rinse cycles.

Filtration media is fouled Manually initiate a Clean Rinse cycle (See Page 15).

If the filtration media is frequently fouling, it may be necessary to increase the fre- quency of Clean Rinse cycles.

Water has objectionable taste and/or odor

System is in bypass Move bypass valve(s) to normal operating (non-bypass) position

Filtration media is fouled Manually initiate a Clean Rinse cycle (See Page 15).

If the filtration media is frequently fouling, it may be necessary to adjust the frequen- cy of Clean Rinse cycles.

No water flow to drain during Clean Rinse cycle

System is in bypass Move bypass valve(s) to normal operating (non-bypass) position.

Drain flow control is plugged Clean drain flow control (See Page 19).

Drain hose is plugged or kinked Straighten drain hose.

Transformer is unplugged from wall electrical outlet (display will be blank)

Check for loss of power and correct.

Clean Rinse cycle does not run automatically

If display reads “VAC”, then Clean Rinse function has been disabled

Press and release the CLEAN button until display no longer reads “VAC”.

If display is blank, transformer may be unplugged from wall electrical outlet

Check for loss of power.

Clean Rinse cycle does not run at the pro- grammed time of day

If time display is flashing, then a long power loss caused the clock to lose its time setting

Reset the clock to the correct time of day (See Page 14).

Valve motor stalled or clicking

Motor is defective or inner valve defect is causing high torque on the motor

Replace rotor/seal kit (instructions includ- ed with kit).

Replace motor and switch (See parts list at end of this manual).

Page 19 of the Whirlpool WHELJ1 user manual — CLEANING THE DRAIN FLOW CONTROL
Page 19 · click to enlarge
Page 19

Troubleshooting

PROBLEM CAUSE CORRECTION

Error Code E1, E3 or E4 appears

Wiring harness or connections to posi- tion switch

Replace wiring harness or connection to position switch (See parts list at end of this manual).

Switch Replace switch (See parts list at end of this manual).

Valve defect causing high torque Replace rotor/seal kit (instructions includ- ed with kit).

Motor inoperative Replace motor (instructions included with motor)

Error Code E5 appears Electronic control Replace electronic control board (PWA) (instructions included with PWA).

Procedure for removing error code from display:

1. Unplug transformer from electrical outlet.
2. Correct problem.
3. Plug in transformer.
4. Wait 6 minutes. The error code will return if the problem was not corrected.

Assistance from customer service may be needed with the following:

PROBLEM CAUSE CORRECTION

Water running to the drain (while unit is not in the Clean Rinse cycle)

Inner valve defect causing leak Replace seals and rotor

Filter media in household plumbing

Crack in distributor or riser tube Replace distributor or riser tube.

CLEANING THE DRAIN FLOW CONTROL

REMOVING DRAIN FITTING TO CLEAN FLOW CONTROL

This procedure is not required if the Central Water Filtration System is operating normally. It should be performed only if a problem with lack of water flow to drain is encountered, as detailed in the troubleshooting table on page 18.

1. Remove the clip holding the drain fitting into the valve (See Figure 23).
2. Remove the drain fitting from the valve
3. Clear any obstruction.
4. Reinstall the drain fitting into the valve.
5. Reinstall the clip to secure the drain fitting in the valve.
Show 5 more labels / short text on this page
Clip · Flow Control · Drain Fitting · Hose Clamp · Drain Hose
Page 20 of the Whirlpool WHELJ1 user manual — REASSEMBLING FILTER SCREEN
Page 20 · click to enlarge
Page 20

Troubleshooting

CLEANING THE SEDIMENT FILTER SCREEN

This procedure is not required if the Central Water Filtration System is operating normally. It should be performed only if a problem with low water pressure at household faucets is encountered, as detailed in the troubleshooting table on page 18.

1. Press and hold the CLEAN button for a few seconds, until “RECHARGE NOW” begins to flash in the display.
2. When water begins to flow from the valve drain hose, place the bypass valve(s) in bypass position (See Figure 11 on Page 12).

REMOVING VALVE ASSEMBLY

Valve Clamp Sections (2)

ed, to relieve water pressure in the tank.

3. Unplug the transformer from the wall electrical outlet.
4. Remove the cover and hang it from the post on front of rim (See Figure 9 on Page 10).
5. Pull the two clips at the inlet and outlet fittings. Slide the adaptors, or bypass valve, from the Central Water Filtration System valve.
6. Remove the clamp retainers (2) and clamp sections (2) that hold the valve to the tank (See Figure 25). Lift upward to remove the valve.
7. Remove the small o-ring (See Figure 26).
8. Remove the screen from the top distributor. Rinse off the screen.
9. Use water to flush the tank top opening. Then, replace the top distributor and o-ring. Be sure to located o-ring seal correctly (See Figure 26).

REASSEMBLING FILTER SCREEN

Small O-ring Filter Screen

10. Install the valve assembly and retaining clamps. Double check to be sure clamps and retainers are securely fastened in place.
11. Referring to the installation instructions, reconnect the Central Water Filtration System to the plumbing. Be sure the plumbing is held firmly in place in the valve inlet and outlet.
12. Return the plumbing bypass valve(s) to normal operating position (non-bypass).
13. Plug the transformer back into the wall electrical outlet. The Central Water Filtration System will complete the Clean Rinse cycle initiated in Step 1, and will automatically return to normal operation.
Show 9 more labels / short text on this page
Clips (2) · Bypass · Valve · Retainers (2) · Large O-ring · Rim · Tank · Top Distributor · Stand pipe
Page 21 of the Whirlpool WHELJ1 user manual — BACK OF CONTROLLER
Page 21 · click to enlarge
Page 21

Wiring Schematic

BACK OF CONTROLLER

24VDC

24VAC

NC

MOTOR

NO TRANSFORMER

POSITION

SWITCH

Specifications

Rated Service Flow Rate 6.0 gpm

Pressure Drop at Rated Service Flow 10 psig

Pressure Drop at 9.6 gpm 15 psig*

Water Pressure Limits (minimum / maximum) 30 - 125 psi

Water Temperature Limits (minimum / maximum) 40 - 120 °F

Drain Flow Rate 3.4 gpm

Rated Capacity 570,000 gal.

Estimated Total Capacity (extrapolated from labo- ratory test data) 1,500,000 gal.

* From independent laboratory test data.

120VAC 60Hz · Model WHELJ1

Page 22 of the Whirlpool WHELJ1 user manual — CENTRAL WATER FILTRATION SYSTEM WARRANTY
Page 22 · click to enlarge
Page 22

Warranty

CENTRAL WATER FILTRATION SYSTEM WARRANTY

WarrantorEcodyne Water Systems Inc., 1890 Woodlane Drive, Woodbury, MN 55125

Warrantor guarantees, to the original owner, that:

One Year Full Warranty: For a period of one (1) year after installation, all parts will be free from defects in materials and workman- ship and will perform their normal functions. For a period of one (1) year after installation, labor to repair or replace any part deemed to be defective in materials or workmanship, will be provided at no additional cost.

Limited Warranties: Limited ten (10) year warranty, from date of purchase, the fiberglass filtration media tank will not rust, cor- rode, leak, burst, or in any other manner, fail to perform its proper functions; and that Limited three (3) year warranty, after installation, electronic control board will be free of defects in materials and workmanship and will perform its normal functions.

If, during such respective period, a part proves to be defective, Warrantor will ship a replacement part, directly to your home, without charge. After the first year, labor necessary to maintain this product is not covered by the product warranty. If you have questions regarding a warranted product, need assistance with installation or troubleshooting, wish to order a part or report a warranty issue, we are just a phone call away. SIMPLY DIAL 1-866-986-3223, Monday - Friday, 8 am - 9 pm EST, for assistance.

General Provisions The above warranties are effective provided the Central Water Filtration System is operated at water pressures not exceeding 125 psi, and at water temperatures not exceeding 120°F; provided further that the Central Water Filtration System is not subject to abuse, misuse, alteration, neglect, freezing, accident or negligence; and provided further that the Central Water Filtration System is not damaged as the result of any unusual force of nature such as, but not limited to, flood, hurricane, tornado or earthquake. Warrantor is excused if failure to perform its warranty obligations is the result of strikes, government regulation, materials shortages, or other circumstances beyond its control.

*THERE ARE NO WARRANTIES ON THE CENTRAL WATER FILTRATION SYSTEM BEYOND THOSE SPECIFICALLY DESCRIBED ABOVE. ALL IMPLIED WARRANTIES, INCLUDING ANY IMPLIED WARRAN- TY OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE, ARE DISCLAIMED TO THE EXTENT THEY MIGHT EXTEND BEYOND THE ABOVE PERIODS. THE SOLE OBLIGATION OF WAR- RANTOR UNDER THESE WARRANTIES IS TO REPLACE OR REPAIR THE COMPONENT OR PART WHICH PROVES TO BE DEFECTIVE WITHIN THE SPECIFIED TIME PERIOD, AND WARRANTOR IS NOT LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES. NO WARRANTOR DEALER, AGENT, REP- RESENTATIVE, OR OTHER PERSON IS AUTHORIZED TO EXTEND OR EXPAND THE WARRANTIES EXPRESSLY DESCRIBED ABOVE.

Some states do not allow limitations on how long an implied warranty lasts or exclusions or limitations of inci- dental or consequential damage, so the limitations and exclusions in this warranty may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. This warranty applies to consumer-owned installations only.

® Registered trademark/TM Trademark of Whirlpool, USA. Manufactured under license by Ecodyne Water Systems, Woodbury, Minnesota.

© 2006 Whirlpool Corporation. All rights reserved.

Page 23 of the Whirlpool WHELJ1 user manual — Notes
Page 23 · click to enlarge
Page 23

Notes

Page 24 of the Whirlpool WHELJ1 user manual — Care of Your Central Water Filtration System
Page 24 · click to enlarge
Page 24
Whirlpool WHELJ1 — Care of Your Central Water Filtration System diagram (page 24)
Fig. 3 · Care of Your Central Water Filtration System
Page 25 of the Whirlpool WHELJ1 user manual — Questions? Visit www.whirlpool.com or call Toll Free 1-866-986-3223
Page 25 · click to enlarge
Page 25

Central Water Filtration System Parts List

Key No. Part No. Description

7290876 Assembly, Replacement Mineral Tank, w/media & asso- ciated components (Includes Key Nos. 1 through 12) 1 7170296 O-Ring, 2-7/8” x 3-1/4”

2 7170254 O-Ring, 13/16” x 1-1/16”

3 7077870 Top Distributor

4 7265025 Filter Screen

5 7170270 O-Ring, 2-3/4” x 3”

6 7105047 Repl. Bottom Distributor

7 7088033 Retainer Clip (2 req.)

8 7176292 Clamp Section (2 req.)

9 Mineral Tank, 8” x 25”

10 Activated Carbon, 10 lbs.

11 Filter Sand, 5 lbs.

12 Gravel, 6 lbs.

13 7290402 Faceplate Decal

14 7290119 Cover (order decal below)

15 7290779 Whirlpool Badge

16 7290729 Repl. Electronic Control Board (PWA)

18 7290680 Outer Shroud Tank

20 7259927 Wire Harness

21 7290509 Drain Tube, 10 ft.

22 1103200 Tube Adaptor (Elbow)

23 7248729 Grounding Kit

24 7278434 Bypass Valve

25 7116713 Clip (2 req.)

Not illustrated.

Mineral Tank and media can only be purchased as part of the Replacement Mineral

Tank Assembly (See top of list).

To order repair parts call toll free 1-866-986-3223, Monday - Friday, 8 am - 9 pm EST.

Manufactured and warranted by

Ecodyne Water Systems, Inc.

1890 Woodlane Drive Woodbury, MN 55125

Questions? Visit www.whirlpool.com or call Toll Free 1-866-986-3223

17 7290101 Rim · 19 7275907 Transformer

Page 26 of the Whirlpool WHELJ1 user manual — Care of Your Central Water Filtration System
Page 26 · click to enlarge
Page 26
Whirlpool WHELJ1 — Care of Your Central Water Filtration System diagram (page 26)
Fig. 4 · Care of Your Central Water Filtration System
Page 27 of the Whirlpool WHELJ1 user manual — Questions? Visit www.whirlpool.com or call Toll Free 1-866-986-3223
Page 27 · click to enlarge
Page 27

Valve Parts List

Key No. Part No. Description

50 7224087 Screw, #8-32 x 1” (2 req.)

51 7286039 Motor (incl. 2 ea. of Key No. 50)

52 0900857 Screw, #6-20 x 3/8” (2 req.)

53 7231385 Motor Plate

55 7284964 Cam & Gear

56 7142942 Clip, Drain

57 0900431 Tubing Clamp (2 provided)

58 7024160 Adapter, Drain Hose

59 7170327 O-Ring, 5/8” x 13/16”

60 7290410 Flow Plug

61 7170238 O-Ring, 7/16” x 5/8”

62 7170212 O-Ring, 3/4” x 15/16”

63 7082087 Wave Washer

64 7199232 Rotor & Disc

65 7170246 O-Ring, 3-3/8” x 3-5/8”

66 7134224 Rotor Seal

67 7170204 O-Ring, 3/8” x 9/16”

68 7092642 Plug, Drain Seal

70 7116713 Clip (2 req.)

71 7278442 Installation Adapter (2 req.)

72 7170288 O-Ring (2 req.)

73 7082053 Valve Body

74 7081764 Seal, Nozzle & Venturi

75 7170319 O-Ring, 1/4” x 3/8” (2 req.)

76 7100940 Plug, Aspirator Port

77 7081201 Retainer, Nozzle & Venturi

78 7085263 Valve Cover

79 7074123 Screw, #10-14 x 2 (5 req.)

80 7077472 Expansion Pin

83 7070412 Screw, #4-24 x 1-1/8”, Flat Head

To order repair parts call toll free 1-866-986-3223, Monday - Friday, 8 am - 9 pm EST.

Manufactured and warranted by

Ecodyne Water Systems, Inc.

1890 Woodlane Drive Woodbury, MN 55125

Questions? Visit www.whirlpool.com or call Toll Free 1-866-986-3223

Show 4 more labels / short text on this page
54 0503288 Bearing · 69 7129889 Spring · 81 7030713 Switch · 82 7117816 Spacer
Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Water has black or gray color(NEW SYSTEM) Start up procedure has not been completedRun start up procedure (See Page 13) or run consecutive Clean Rinse cycles (See Page 15) until water color returns to nor- mal. p.18
Water has black or gray color(NOT A NEW SYSTEM) Normal abra- sion of filtration mediaManually initiate a Clean Rinse cycle (See Page 15). p.18
Low water pressure at house faucetsSediment filter screen is cloggedManually initiate a Clean Rinse cycle (See Page 15). p.18
Low water pressure at house faucetsClean sediment filter screen (See Page 20). If the filter screen is frequently plug- ging, it may be necessary to adjust the frequency of Clean Rinse cycles. p.18
Low water pressure at house faucetsFiltration media is fouledManually initiate a Clean Rinse cycle (See Page 15). p.18
Low water pressure at house faucetsIf the filtration media is frequently fouling, it may be necessary to increase the fre- quency of Clean Rinse cycles. p.18
Water has objectionable taste and/or odorSystem is in bypassMove bypass valve(s) to normal operating (non-bypass) position p.18
Water has objectionable taste and/or odorFiltration media is fouledManually initiate a Clean Rinse cycle (See Page 15). p.18
Water has objectionable taste and/or odorIf the filtration media is frequently fouling, it may be necessary to adjust the frequen- cy of Clean Rinse cycles. p.18
No water flow to drain during Clean Rinse cycleSystem is in bypassMove bypass valve(s) to normal operating (non-bypass) position. p.18
No water flow to drain during Clean Rinse cycleDrain flow control is pluggedClean drain flow control (See Page 19). p.18
No water flow to drain during Clean Rinse cycleDrain hose is plugged or kinkedStraighten drain hose. p.18
No water flow to drain during Clean Rinse cycleTransformer is unplugged from wall electrical outlet (display will be blank)Check for loss of power and correct. p.18
Clean Rinse cycle does not run automaticallyIf display reads “VAC”, then Clean Rinse function has been disabledPress and release the CLEAN button until display no longer reads “VAC”. p.18
Clean Rinse cycle does not run automaticallyIf display is blank, transformer may be unplugged from wall electrical outletCheck for loss of power. p.18
Clean Rinse cycle does not run at the pro- grammed time of dayIf time display is flashing, then a long power loss caused the clock to lose its time settingReset the clock to the correct time of day (See Page 14). p.18
Valve motor stalled or clickingMotor is defective or inner valve defect is causing high torque on the motorReplace rotor/seal kit (instructions includ- ed with kit). p.18
Valve motor stalled or clickingReplace motor and switch (See parts list at end of this manual). p.18
Error Code E1, E3 or E4 appearsWiring harness or connections to posi- tion switchReplace wiring harness or connection to position switch (See parts list at end of this manual). p.19
Error Code E1, E3 or E4 appearsSwitchReplace switch (See parts list at end of this manual). p.19
Error Code E1, E3 or E4 appearsValve defect causing high torqueReplace rotor/seal kit (instructions includ- ed with kit). p.19
Error Code E1, E3 or E4 appearsMotor inoperativeReplace motor (instructions included with motor) p.19
Error Code E5 appearsElectronic controlReplace electronic control board (PWA) (instructions included with PWA). p.19
Water running to the drain (while unit is not in the Clean Rinse cycle)Inner valve defect causing leakReplace seals and rotor p.19
Filter media in household plumbingCrack in distributor or riser tubeReplace distributor or riser tube. p.19

Ask about the Whirlpool WHELJ1

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Whirlpool WHELJ1

Be the first to ask — other owners or our team will answer.

Original document

Whirlpool WHELJ1 manual PDF

27 pages·2.5 MB·Water Dispenser·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…