WHIRLPOOL UNDERCOUNTER WATER FILTRATION
SYSTEMS I, II, & Ill
m 1

Remove parts from packages. Check that you have all the parts.
filtration assembly System I (A) filtration assembly System II (B) filtration assembly System III (C) filtration assembly cover (D) 2 mounting screws (E) VI” blue tubing (F) VI” orange tubing (G) 2-way grey connector with push-in saddle valve assembly (I) insert (J) plastic sleeve (K) brass compression nut (L) literature package
Materials Needed for Basement Installation
l step ladder l Additional tubing, 9 VI” drill bit Part No. 4319151 available
l safety glasses from your Whirlpool dealer.
Materials Needed for Optional Sink Faucet Installation Sink faucet, Part No. 4319154, available from your Whirlpool dealer. Includes: faucet base with blue tubing attached, assembly hardware, faucet spout, 2-way grey connector with push-in ends, and a “T” grey connector with push-in ends,
Massachusetts CMR 248 strictly prohibits the use of saddle-type valves. The feed-water connection must conform to applicable plumbing codes.

Before You Start . . .
It is recommended that this system be installed by a licensed plumber. Refer to the Use & Care information at the end of this booklet. If you need more help,
It is the responsibility of the installer to comply with the the Whirlpool Consumer Assistance Center will answer any questions you may have
installation specifications provided and with state and local about operating or maintaining your water filtration system. The Whirlpool Consumer
plumbing codes. Assistance Center is open 24 hours a day, 7 days a week. Just dial l-800-253-1301-the call is free. If you decided to install the system yourself, see “General Information” on page 9 before continuing.
When you call, you will need the water filtration system model number and serial number. Both Water Filtration Svstems I. II and Ill can be installed in the basement if numbers can be found labeled on the filtration there is not adeqiate room for under-sink installation. Order additional assembly. tubing, Part No. 4319151 from your Whirlpool dealer.
DO NOT use filtration system if water is micro- biologically unsafe or water quality is unknown.
Water Filtration Systems I, II & 111
&Turn off cold water supply. *Turn on faucet to drain water from line.
l Connect saddle valve to cold water suppty. Turn saddle valve handle clockwise until piercing lance enters pipe and stops. *Connect one end of orange tubing lo saddle valve. Connect other end to filtration assemblv. a ‘SYSTEM CONNECTION
l Decide if the system will be connected
to your refrigerator, to an optional faucet or to both. l Connect refrigerator’s water supply to filtration assembly with blue tubing. l Or, install faucet in sink and connect
connector to connect





Instructions At A Glance l For detailed instructions see following page.












Electrical Shock Hazard Special care must be taken when drilling into water pipes. Some water may remain in water supply pipe:
1. Turn off cold water supply. (St; la-lb)


l If an electric drill is used, it must be properly grounded to prevent severe or lethal shock if water should enter drill.


l Use only an electric drill that is double insulated or properly grounded.

l Check with qualified electrician if you are in doubt as to whether your electric drill is properly grounded.

l Only drill at top or side of horizontal water supply pipe. DO NOT drill at bottom of horizontal pipe where water may remain. Failure to follow these instructions could result in personal injury or death.













j i 1 li 5 * Ih Connect saddle valve to cold water supply . rigid metal or plastic pipe. Use a grounded


Connect saddle valve to cold water supply . soft copper pipe. Check that saddle valve piercing lance does not protrude beyond rubber gas- ket. If it is protruding, carefully push it in flush with the rubber gasket, using a hard object like the end of a screwdriver handle.

Product Damage DO NOT connect to a hot water supply line. Failure to follow this instruction could result in product damage.
electric drill or a hand drill to drill 3h6” hole in top side of horizontal pipe or side of vertical pipe. This will keep sediment from ‘collecting in valve. Turn saddle valve handle clockwise to expose piercing lance a maximum of %6” beyond the rubber gasket. Align piercing lance over hole you drilled in pipe. Then assemble saddle valve on pipe with large “U” side against pipe.



Take note of water requirements listed under . the Use & Care section of this booklet. The filtration system’s feed line (orange tubing) connects to your cold water supply line using the saddle valve.

Tighten bottom screw firmly, . keeping bracket parallel to pipe Turn saddle valve handle clockwise until oiercina lance enters hole in pipe and then stops. The saddle valve is now in the closed position.


Do not use saddle valve if it is prohibited by your state or local plumbing codes.

The saddle valve is for use with 3/s” to s/B” outer diameter (O.D.), soft copper pipe (plain or chrome plated) or rigid metal or plastic pipe. Important: DO NOT use the saddle valve on flexible ribbed tubing. The wall thickness of flexible ribbed tubing is thin and will not support the saddle valve supplied.
Have a towel ready in case of . leaks. Turn on cold water supply to check for leaks. In case of leaks, use an adjustable wrench to tighten nut below valve’s handle. Turn cold water back off. Ik

Assemble saddle valve on copper pipe. . Saddle valve must be on top side of horizontal pipe or side of vertical pipe to keep sediment from collecting in its valve.


If your cold water supply is connected to the cold water faucet with flexible ribbed tubing, contact your local plumbing supply distributor to obtain special connecting hardware.
If you are connecting the saddle valve to 3/e” O.D. copper pipe, assemble bracket with small “U” side against copper pipe to prevent distortion of pipe. If you are connecting the saddle valve to %6” to W O.D. pipe, assemble bracket with large “U” side against copper pipe. le

Remove cover from filtration . assembly by lifting straight up. _ Move filtration assembly near


area wnere it will be mounted - either under sink or in the basement. For best results, locate filtra- tion assembly so tubing can be cut to shortest length possi- ble. To connect one end of orange tubing to the saddle valve, place the brass compression nut on the orange tubing (threaded side out) place the plastic sleeve onto the tubing (discard brass sleeve), push the insert into the tubing and thread this assembly onto the opening of the saddle valve. Tighten brass compression nut with %” wrench Use a plastic tubing cutter or sharp razor knife to cut tubing to shortest possible length. Make sure cut end is clean and blunt and tubing is round. Push free end of orange tubing as far as it will go into the grey push-in fitting on the front right side of the filtration assembly.

Tighten bottom screw firmly. DO NOT . over-tighten; copper pipe could be crushed.



l DO NOT install tubing in an area where temperatures drop below 32°F.

l DO NOT overtighten saddle valve to copper pipe. This will crush pipe.

Have a towel ready in case of leakage. Turn . saddle valve handle clockwise until the lance pierces soft copper pipe and then stops. Do not continue to turn the saddle valve handle after it has stopped because you may pierce through the opposite side of pipe. The saddle valve is now in the closed position.
l Keep a bucket or towel under area where

saddle valve connection is made. Failure to follow these instructions may result in water damage to property or product damage. lb


Turn off cold water SUDDIV. Turn on cold . water faucet and allow all water to drain from line. Turn off faucet. Determine if your cold water sup- ply line is soft copper pipe or rigid metal or plastic pipe. If your cold water supply line is soft copper pipe, pro- ceed to step 1 c. If your cold water supply line is rigid metal or plastic pipe, skip ahead to step 1 h.

Turn on cold water supply to check for . leaks. In case of leaks, use an adjustable wrench to tighten nut below valve’s handle. Turn cold water back off and proceed to step 1 k.


3:;







Instructions At A Glance l For detailed instructions see following page.

































2a You have three installation options: . 1 .Connect water supply from filtration system
2d Connect system to optlonal sink faucet . only. A S/16” diameter opening in the sink is required to install the optional sink faucet. Important: If you do not have an existing sink opening, contact a qualified installer or licensed plumber to cut an opening in your sink.
2f Recheck faucet position. If . position needs minor adjusting wrap the flat chrome sides of faucet and the crescent portion of the crescent wrench with masking tape to protect the chrome from scratches. Use the \Nrench on flat sides of faucet to reposition faucet. Remove masking tape.

to refrigerator’s ice and water only. 2.Connect water supply from filtration system to optional sink faucet only. 3.Connect water supply from filtration system to both refrigerator and optional sink faucet.



All parts are included with this kit to connect refrigera- tor. If you choose to connect filtration system to a sink faucet, order sink faucet, Part No. 4319154, available from your Whirlpool dealer. This kit includes: faucet assembly with blue tubing attached, assembly hard- ware, faucet spout, 2-way grey c6nnectoi with push-in ends, and a ‘7” grey connector with push-in ends. This ‘7” grey connector with push-in ends will allow you to connect filtration assembly to both the faucet and the refrigerator. 2b Connect system to refrigerator only. . Remove and discard short piece of blue tub- ing from grey connector with push-in end on the back of filtration assembly. Insert one end of long piece of blue tubing into this grey connector with push-in end. Run the blue tubing from the filtration assembly to the refrigerator. J-z-l

Remove and discard short piece of blue . tubing from grey connector with push-in en on the back of filtration assembly. Cut blue tubing from faucet to shortest possible length. Insert free end of faucet’s blue tubing into this grey connector with push-in end. Proceeg step 3.

l Contact a qualified installer or licensed

plumber for cutting a faucet opening in your &ink.

l Failure to do so may result in damage to
the sink.

2e Remove and discard short clear piece of . tubing from top of faucet base and push faucet spout into this opening. Place the escutcheon plate and black rubber washer on the faucet’s thread- ed nipple. Note: Rubber washer may be removed and replaced with a bead of plumber’s putty for a neater appearance. Feed blue tubing through sink hole. Position faucet spout over sink. Working below the sink, secure faucet with black plastic washer, locking washer and nut.



2h Connect systemTo refrigerator and . optional sink faucet. Follow steps 2d through 2f for faucet installation. It is strongly recom- mended that only a licensed plumber or professional installer cut an opening in the sink. Cut blue tubing from faucet to shortest possible length. Push the faucet’s blue tubing as far as it will go onto one end of the ‘7” grey connec- tor. Push the other end of the ‘T” grey connector as far as it will go onto the short piece of blue tubing on the back of the filtration assembly. Push the long piece of blue tubing onto the center push-in end of the ‘7” grey connector.




Side view of faucet


2c . Route blue tubing to rear of refrigerator. Cut blue tubing to shortest possible length. Inset-f free end of blue tubing into the’2-way greyconnector with push-in ends as far as it will go. Turn off refriger- ator water supply and ice maker. Press refrigerator water dispenser to empty water into a container. Disconnect main water supply from refrigerator’s water line. Seal main water line hole because it will no longer be connected to refrigerator. Make sure the refrigerator water line has a square cut. Then insert refrigerator water line into other end of the 2-way grey connector with push-in ends. Proceed to step 3.


Route blue tubing to refrigerator. Cut blue tub- . ing to shortest possible length. Insert free end of blue tubing into the 2-way grey connector with push- in ends as far as it will go. Turn off refrigerator water supply and ice maker. Press refrigerator water dis- penser to empty water into a container. Disconnect main water supply from refrigerator’s water line. Seal main water line hole because it will no longer be con- nected to refrigerator. Make sure the refrigerator water line has a square cut. Then inset-l refrigerator water line into other end of the 2-way grey connector with push-in ends. Proceed to step 3.







I 2-MY PY connector
Ion ‘blue tu Ing BI

Ion ‘blue tu Ing %

Instructions At A Glance l For detailed instructions see following page.

3d Place a towel or bucket under saddle valve, . then turn on cold water supply and saddle valve and check for leaks. 3e If filtration assembly was connected to refrig- . erator, let ice maker produce two batches of ice and discard both batches. This will flush the line of any accumulated particles. If the refrigerator has a water dispenser, flush the line by dispensing 2-3 gallons of water.
3f If optional sink faucet was installed, lift faucet . handle and dispense and discard the first 2-3 gallons of water. To get filtered water hold the faucet handle down for momentary flow, or hold the faucet up for continuous flow. To stop water flow from the faucet, return the faucet to the center or horizontal position.
Electrical Shock Hazard Special care must be taken when drilling into walls. Electrical wires may be concealed behind the wall covering: - Use only an electric drill with a 3-wire power supply cord connected to a grounded receptacle.
l Check with qualified electrician if you are in doubt as to whether your electric drill is properly grounded. Failure to follow these instructions could result in personal injury or death. 3a Mount filtration assembly: . Solid Construction Cabinet: Position the filtration assembly on either the right or left cabinet wall and allow a minimum of 2” clearance above the cabinet floor. Mark the location of the filtration system’s bracket holes, then set the filtration assem- bly aside and skip ahead to step 3b. Non-solid Construction Cabinet: Replace filtration assembly’s cover. Position the filtration assembly on the cabinet floor along either the right or left cabinet wall. Skip ahead to step 3c.
n Due to shipping, some carbon grains may appear in the first few gallons of water through your filtration
system. Simply flush the system until water becomes clear.
l This system can be connected to two dispensing points (including the optional sink faucet). We do not recommend installing this water filtration system to your existing tap faucet as the flow rate will be reduced to .6 gallons per minute.
l Remember to cut all tubing to the shortest possible length to maximize your flow rate.
Basement Installation: Position the filtration assembly on wood floor supports or on basement wall. Mark the location of the filtration assembly’s bracket holes, then set the filtration assembly aside. Additional tubing may be required and is available from your local plumbing distributor or from your Whirlpool dealer. Continue with step 3b.
l Maintenance of this water filtration system is very important.
Replace the Sediment (S), Lead Reduction (L), and Carbon Filter (CF) cartridges annually. Failure to maintain this water filtration system over an extended period of time could present health risks.
3b Drill pilot holes for the mounting bracket at . the locations you’ve marked. Insert mountin! bracket screws in holes and tighten, leaving a slight gap between screw head and wall.
For basement installation and solid construction cabinet installation, place filtration assembly mount- ing bracket on mounting screws and tighten screws until filtration assembly is secure and replace cover. 3c Make sure all tubing connected to grey . push-in connectors is tight (pushed in as far as it will go) and that tubing does not bind or kink anywhere. Also make sure tubing does not interfere with cabinet storage areas. Tubing may be cut to a shorter length if necessary. Tubing may be secured I cabinet walls with insulated staples as long as staple do not crush or puncture tubing.

Replacing filter cart ridges 1. Turn off water supply at either saddle valve or main shut-off. Press refrigerator water dispenser to empty water into a container. If using the optional sink faucet, turn on faucet to drain any water in system. Discard this water. Wait five minutes for filtration assembly to depressurize. 2. Lift cover off filtration assem- bly. Rotate cartridge one-quarter sl turn to the left to remove connector tabs from receptacle. Gently pull down to remove cartridge.
9 If a cartridge head leaks, it may have a misaligned, pinched or damaged O-ring. Shut off the SI saddle valve or other existing water valve. Press refrigerator water supply or optional sink faucet to drain water from system. Wait five minutes for filtration assembly to depressurize. Turn filter cartridge l/4 turn to the left and remove. Replace the O-ring if it is misaligned, pinched or damaged.
The filtration system must be connected to a cold water supply line providing 30-l 00 psi water pressure. The water temperature must be between 40”-100°F. Community or private well water must be potable (suitable for drinking).
DO NOT use water filtration system if water is microbiologically unsafe or water quality is unknown. Failure to follow these instructions could result in personal injury.
l To correct a leaky saddle
tabs top of the new cartridge with the slots in the filtration assembly’s receptacle. Push cartridge up and turn it l/4 turn to the right to lock it into place. Cartridge label must face front. Pull down on cartridge to make sure it’s firmly in place. Repeat step if cartridge disconnects.
valve, turn off cold water supply and make sure bot- tom screw is tightened eve
and firmly. DO NOT overtighten, you could crush the pipe. Then make sure the nut below the saddle valve’s handle is tight. If not, tighten it with a 7/B” wrench.
The maximum length of time a filter cartridge should be used is one year. Cartridges should be replaced every 500 gallons, but exactly how often cartridges are replaced will depend on local water conditions. Private wells may require more frequent cartridge replacement while softened water systems may require cartridge replacement only once a year.
l If the threaded portion of the brass compression nut that is attached to the saddle valve leaks, turn off saddle valve and remove the nut, wrap Teflon tape around the threaded portion 2-4 times. Reconnect the nut.
l If a leak should occur at a push-in connector, the
Follow these instructions if system will not be used for more than 30 days. 1. Turn off water supply at either saddle valve or main shut-off. Press refrigerator water dispenser to empty water into a container. If using the optional sink faucet, turn on faucet to drain any water in system.
cause is usually defective tubing. To correct the
problem, turn off water supply to the
Or replace if or when...
system either at the saddle valve or other existing water valve. Push in the grey push-in connector and hold; then pull the tubing out of the connector. Cut at least l/4” from the end of the tubing clean,squarecut using a plastic tubing cutter or a sharp razor knife. Make sure the cut end is clean and blunt and that tubing is round. Reinsert tubing as far as it will go. Turn on water supply at valve.
-Water supply is cloudy,
every 1,000 gals.
has high dirt and rust content change every I, six mont 5) *Water amount or flow jre\;;z;cet is noticeably
Discard this water. Wait five minutes for filtration assembly to depressurize.
*Water supply smells of chlorine or water has high dirt and rust content change every I, six mont s)
l If the refrigerator tubing leaks at the push-in connec-
I Carbon (CF) Once/ ear or every 5 00 gals.
-Water has “off” taste
tor, the refrigerator’s water line metal tubing may be grooved or deformed. To correct the problem, turn off water supply to the system either at the saddle valve or other existing water valve. Press refrigerator water supply or optional sink faucet to drain water from system. Wait five minutes for filtration assembly to depressurize. Push in the grey push-in connector and hold; then pull the tubing out of the connector. Cut at least VI” from the end of the tubing to create a new smooth end or replace if necessary.
Using water filtration system after long periods of non-use 1. Follow instructions for replacing cartridges.
Maintenance of this water fillration system is very important. Replace the Sediment (S), Lead Reduction (L), and Carbon Filter (CF) cartridges annually. Failure to maintain this water filtration system over an extended period of time could present health risks.



Call l-800-253-1301 to order.

WATER FILTRATION SYSTEM I MODEL NO. WSClOOYW

System I Replacement Cartridge Kit Kit includes Sediment/Carbon (SC) Cartridge 4373529
RATED SERVICE FLOW - 0.6 gpm (2.28 Ipm) MAX. OPERATING PRESSURE -100 psig (862 kPa) MAX. OPERATING TEMPERATURE 100°F (36°C)

System II Replacement Cartridges Kii Kit includes Lead Reduction (L) and Carbon Filter (CF) Cartridges. Cartridges can also be ordered individually. 4373573


System Ill Replacement Cartridge Kit Kit includes Lead Reduction (L) and two Carbon Filter (CF) Cartridges. Cartridges can also be ordered itkhidual/y. - 14373574 SedimenVCarbon (SC) Cartridge 14373529
IT IS ESSENTIAL THAT OPERATIONAL, MAINTENANCE AND FILTER REPLACEMENT REQUIREMENTS NSF@ BE CARRIED OUT FOR THE PRODUCT TO PERFORM AS ADVERTISED. 0

THIS PRODUCT HAS BEEN TESTED AND LISTED UNDER NSF STANDARD 42 FOR CHLORINE, TASTE AND ODOR REDUCTION (CLASS I) AND PARTICULATE REDUCTION (CLASS II).

WHIRLPOOL, BENTON HARBOR, MI, USA.

Lead Reduction (L) Cartridge Carbon Filter (CF) Cartridge



Additional Parts 1 14373572 1

I/.” Tubino I431 9151 1 Needed for Multiple Connections: T Connector with Push-in Ends 4319152
RATED SERVICE FLOW - 0.6 gpm (2.20 Ipm) MAX. OPERATING PRESSURE -100 psig (862 kPa) MAX. OPERATING TEMPERATURE 100°F (38%)

Additional tubing for basement installation 4319151


If You Need Assistance...

The Whirlpool Consumer Assistance Center will answer any questions about operating or maintaining your water filtration system not covered in the Installation
THIS PRODUCT HAS BEEN TESTED AND LISTED UNDER NSF STANDARD 42 FOR CHLORINE, TASTE AND ODOR REDUCTION (CLASS I) AND PARTICULATE REDUCTION (CLASS II) AND UNDER NSF STANDARD 53 FOR LEAD, CYST AND TURBIDITY REDUCTION.

WHIRLPOOL, BENTON HARBOR, MI, USA.
NSF@ BE CARRIED OUT FOR THE PRODUCT TO PERFORM AS ADVERTISED.
Instructions and Use and Care Guide. The Whirlpool Consumer Assistance Center is open 24 hours a day, 7 days a week. Just dial 1-800-253-1301 - the call is free. When you call, you will need the water filtration system model number and serial number. Both num- bers can be found labeled on the filtration assembly.




How To Arrange For Service...
WATER FILTRATION SYSTEM Ill mifl

ol MODEL NO. WSCBOOYW
In the event that your Whirlpool appliance should ever need service, call the dealer from whom you purchased the appliance or a Whirlpool-authorized service company. A Whirlpool-authorized service company is listed in the Yellow Pages of your telephone directory under “Appliances-Major-Service or Repair.” You can also obtain the service company’s name and telephone number by dialing, free within the continental United States, the Whirlpool Consumer Assistance Center telephone number, l-800-253-1 301. A special operator will tell you the name and number of your nearest Whirlpool-authorized service company.

-IIoN RATED SERVICE FLOW - 0.6 gpm (2.28 Ipm) MAX. OPERATING PRESSURE -100 psig (862 kPa) MAX. OPERATING TEMPERATURE 100°F (38°C)



THIS PRODUCT HAS BEEN TESTED AND LISTED UNDER NSF STANDARD 42 FOR CHLORINE, TASTE AND ODOR REDUCTION (CLASS I) AND PARTICULATE REDUCTION (CLASS II) AND UNDER NSF STANDARD 63 FOR LEAD, CYST AND TURBIDITY REDUCTION. SEE PERFORMANCE DATA SHEET FOR PERMISSIBLE VOC CLAIMS.

WHIRLPOOL, BENTON HARBOR, MI, USA.

Maintain the quality built into your Whirlpool appliance - call a Whirlpool-authorized service company.
BE CARRIED WT FOR THE PRODUCT TO PERFORM AS ADVERTISED.

.o

d 14373530 14373531 · Saddle Valve



Particulate reduction (Class II). 0 NSF B for Taste, Odor and Chlorine reduction (Class I) and Particulate reduction (Class II) and under Standard 53 for Cyst, Turbidity and Lead reduction.

This product has been tested and listed by NSF International under B Standard 42 for Taste, Odor and Chlorine reduction (Class I) and
This product has been tested and listed by NSF International under Standard 42


Model No. WSClOOYW Whirlpool Water Filtration System II


SPECIFICATIONS: Taste/Odor/Chlorine reduction (Class I) CAPACITY: 1,000 Gallons SPECIFICATIONS: Lead and Taste/Odor/Chlorine reduction (Class I) CAPACITY: 500 Gallons SERVICE FLOW RATE: 0.6 GPM (2.2 L/&n) @ 60 psi SERVICE FLOW RATE: 0.6 GPM (2.2 tJmin) @‘60 psi

General Average Maximum Minimum% NSF Test General Maximum Minimum% NSF Test Performance lnfluent Eff bent Reduction Requirement Performance

lnfluent Effluent Reduction Requirement

Chlorine’ 2.0 mg/L co.1 mg/L 92% minimum 75% reduction (Class I) Chlorine’ 2.0 mg/L co.1 mg/L 92% minimum7596 reduction (Class I)

Particulate 560,000 part/ml* 18,000 part/ml
98% minimum 85% reduction (Class II)
560,000 part/ml’ 18,000 patVmL minimum 85% 98% reduction (Class II)

Perlotmance may very based on local water conditions. ‘Free Available Chlorine. 2Tesl requirement is at least 10,000 parlkl&mL of AC Fine Test Dust.
215,000 4-6 p/ml3 390 4-6 gmL 99.9% minimum 99.9%

14 NTU 0.42 NTU 97% minimum effluent



Reduction U.i;lA Average Maximum Minimum% NSF Test Performance4 lnfluent Effluent Reduction Requirement
Lead @ pH 6.5 0.015 mg/L 0.16 mgIL5 0.005 mg/L 97% maximum effluent

0.015 mg/L

Lead @ pH 8.5 0.015 mg/L 0.17 mg/mL5 0.002 mg/L 99% maximum effluent
0.015 mg/L

‘Free Available Chlorine. Test requirement is at least 10,000 partiis/mL of AC Fins Test Dust. Test rewiremet- is 4-6 miuommer size ~artidas ger mL of influent. ‘These &ntaminants are not necessarily in your n&r supply. Performance may vary based on local water conditions 5Tast requirement 0.15 mg/L+ 15%.
















This product has been tested and listed by NSF International under Standard 42 for Taste, Odor and Chlorine reduction (Class I) and Particulate reduction (Class II) and under Standard 53 for Cyst, Turbidity, Lead and VOC reduction. Whirlpool Water Filtration System Ill


Water SUDDIV - community or orivate well Potable (suitable for drinking)

Water Pressure 30 -100 psi (207 - 690kPa) I

SPECIFICATIONS: Lead, VOC and Taste/Odor/Chlorine reduction (Class I) CAPACITY: 500 Gallons SERVICE FLOW RATE: 0.6 GPM (2.2 Umin) @ 60 psi

Maximum Minimum% NSF Test Effluent Reduction Requirement

co.1 ?glL 92% minimum75% reduction IClass I)
2.0 mg/L
Dissolved Manganese < 0.05 ppm

Turbidity < 1 NTU
Particulate 560,000 part/ml2 18,000 parVmL 98% minimbm 85% reduction (Class II)
Waier supplies that exceed limits for iron or manganese require pretreatment.

cyst 215,000 4-6 p/mL3 390 4-6 u/mL 99.9% minimum 99.9%
It is essential that operalional, maintenance and filter replacement requirements be carried out for Ihe product to perform as advertised.

Turbidity 14 NTU 0.42 NTU 97% minimum effluent


Reduction U.itfA Average Maximum Minimum% NSF Test Performance4 lnfluent Effluent Reduction Requirement
Length of Warranty:
Whirlpool will pay for:

Lead @ pH 6.5 0.015 mg/L 0.16 mg/L5 I I 0.005 mg/L 97% maximum effluent
One Year Full Warranty (From date of purchase)
Replacement parts and repair labor to correct defects in materials or workmanship for the entire product except for the filter cartridge(s). Service must be provided by an authorized Whirlpool servicing outlet.

0.015 ma/L
Lead @ pH 8.5 0.015 mg/L 0.17 mg/L5 0.002 mg/L 99% maximum effluent

0.015 mg/L
Five Year Limited Warranty (Second through fifth year from date of purchase)
Replacement parts to correct defects in materials or workmanship for the entire product except for the filter cartridge(s).

‘Free Available Chlorine. Test requirement is at leas.1 10,000 ParticletimL of AC Fine Test Dust. 3Tes.l reouirement is 4-6 micrometer size particles per mL of influent. ‘These &taminants are not necessarily in your w&r supply. Perlormance may vary based on local water conditions. 5Test requirement 0.15 rn@ 15%.

Whlrlpool will not pay for:

A. Service calls to:
1.) Correct the installation of the product. System must be installed and operated in accor- dance with Whirlpool procedures and guidelines. 2.) Instruct you how to use the product. 3.) Correct house plumbing. B. Repairs when product is used in other than normal, single-family household use. C. Repairs when product is damaged from neglect, misuse, abuse, freezing or hot water, fouling
VOLATILE ORGANIC CHEMICAL REDUCTION This system has met the testing requirements of Standard 53, Section 5.1.1 for the reduction of chloroform, which is the surrogate for the following chemicals Maximum lnfluent Mlnimum Occurrence Effluent Concentration Percent Chemical Levels (ppb) Level (ppb) Other VOc’s’ Reduction Benzene 30’ ;:



with sediment or scale, bacterial attack, alterations, improper installation, or installation not in accordance with local plumbing codes. D. Any labor costs during the limited warranty. E. Replacement parts or repair labor costs for units operated outside the U.S. F. Pickup and delivery. This product is designed to be repaired in the home. G. Repairs to parts or systems caused by unauthorized modifications made to the product.
95% Carbon Tetrachtortde 40’ Chlorobenzene 80 95% p-Dichlorobenzene 80’ $

Hexachlorobutadiene 40 95% Trichloroethylene 300’ ortho-Xylene 80 95% Trihalomethanes 300 15 trans-1 ,P-Dichloroethene 80 95% (surrogate chemical) 1 ,1,2,2-Tetrachloroethane 80 95% 1, 1 -Dichloroethylene 50’ g:


1,2-Dichlorobenzene 80 95% 1 ,l ,l -Trichloroethane 80’ 1 ,P-Dichloroethane 80 95% 1 ,P-Dichloroethane 100’ Ethylbenzene 802 2:
The performance and functioning of your water filtration system is directly related to the quality of the water being treated and the particular application in which it is used. Please consult “Water Requirements” and “Use 8 Care”.


Whirlpool shall not be Ilable for lncldental or consequential damages. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation or exclusion may not apply to you.
Tetrachloroethylene 802 Toluene 802 ;:

1 ,P-Dichloropropane 80’ 53

‘Influent levels are the 95th percentile, occu~ence levels are per Federal Reg~sler, Vol. 50, No. 219. November 13, 1965. p. 46917. ‘Since the s5m percentile ooxnence levels were too low and thus were not pertinent for testing lhess chemicals against their MCL’s. a reasomble level was selected for surrogate tasting as shown. ‘EPA Primary Maximum Contaminant Levels ‘Maximum eflluem concentrations set at the practical quantitation level (PQL) which is less than the MCL.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

9n the absence oi offiially stated occurrence levels and MCCs. tne surrogate mfluents were selected to provlae a reasonaole IesI.

Part No. 4373576 01993 Whirlpool Corporation
Printed on Recycled Paper in U.S.A.
Owners and our team usually reply within a day — and your question helps the next person too.