EN
3Com logo
Official user manual

3Com 6000

34 pages·225 KB·Network Switch·PDF·ENDEFRITNLJA
3Com 6000
Table of Contents 34 sections Contents · CoreBuilder 6000 Intelligent Switching Software Re... · Overview · Hardware Dependencies · … ShowHide
Page 1 of the 3Com 6000 user manual — ® C ORE B UILDER
Page 1 · click to enlarge
Page 1

® C ORE B UILDER

™ 6000 S OFTWARE I NSTALLATION AND R ELEASE N OTES

CoreBuilder™ Intelligent Switching Software Revision 8.2.0 May 8, 1997

Part No. 801-00381-000 Published May 1997 Revision 01

Page 2 of the 3Com 6000 user manual
Page 2 · click to enlarge
Page 2

3Com Corporation I 5400 Bayfront Plaza I Santa Clara, California I 95052-8145

Copyright © 3Com Corporation, 1997. All rights reserved. No part of this documentation may be reproduced in any form or by any means or used to make any derivative work (such as translation, transformation, or adaptation) without permission from 3Com Corporation.

3Com Corporation reserves the right to revise this documentation and to make changes in content from time to time without obligation on the part of 3Com Corporation to provide notification of such revision or change.

3Com Corporation provides this documentation without warranty of any kind, either implied or expressed, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. 3Com may make improvements or changes in the product(s) and/or the program(s) described in this documentation at any time.

UNITED STATES GOVERNMENT LEGENDS: If you are a United States government agency, then this documentation and the software described herein are provided to you subject to the following restricted rights:

For units of the Department of Defense: Restricted Rights Legend: Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (c) (1) (ii) for restricted Rights in Technical Data and Computer Software clause at 48 C.F.R. 52.227-7013. 3Com Corporation, 5400 Bayfront Plaza, Santa Clara, California 95052-8145.

For civilian agencies: Restricted Rights Legend: Use, reproduction, or disclosure is subject to restrictions set forth in subparagraph (a) through (d) of the Commercial Computer Software - Restricted Rights Clause at 48 C.F.R. 52.227-19 and the limitations set forth in 3Com’s standard commercial agreement for the software. Unpublished rights reserved under the copyright laws of the United States.

Unless otherwise indicated, 3Com registered trademarks are registered in the United States and may or may not be registered in other countries.

3Com, the 3Com logo, and LANplex are registered trademarks of 3Com Corporation. CoreBuilder is a trademark of the 3Com Corporation.

AppleTalk is a registered trademark of Apple Computer Corporation. HP and OpenView are registered trademarks of Hewlett-Packard Corporation. SunNet Manager is a trademark of Sun Microsystems, Inc. MS-DOS, Windows 95, and Windows NT are registered trademarks of Microsoft Corporation. UNIX is a registered trademark in the United States and other countries, licensed exclusively through X/Open Company, Ltd.

Other brand and product names may be registered trademarks or trademarks of their respective holders.

Page 5 of the 3Com 6000 user manual — CoreBuilder 6000 Intelligent Switching Software Re...
Page 5 · click to enlarge
Page 5

COREBUILDER 6000 INTELLIGENT SWITCHING SOFTWARE REVISION 8.2.0

Overview These installation instructions and release notes describe revision 8.2.0 of the CoreBuilder™ 6000 Intelligent Switching software from 3Com Corporation, dated May 8, 1997. This revision supersedes revision 8.0.2, dated December 2, 1996.

Extended Switching Software is also available. It supports IP, IPX, and AppleTalk routing, VLANs, and RMON. To purchase Extended Switching software, contact your sales representative.

CoreBuilder Intelligent Switching software revision 8.0.0 or greater requires that one of the following LANswitching Management Module Plus (LMM+) versions be installed in system slot 1:

I Revision 1.21 or greater of the revision 1 LMM+

I Revision 2.12 or greater of the revision 2 LMM+

If you attempt to run CoreBuilder system software 8.0.0 or greater on an earlier revision of the LMM+, the system fails to reboot automatically when you turn it on.

To reboot a system that has failed to reboot automatically, connect a terminal to the serial port on the LMM+ installed in the system. When asked if you want to “ignore the checksum error,” enter y (yes). The system reboots.

Hardware Dependencies

Page 6 of the 3Com 6000 user manual — Upgrading Your LMM or LMM+
Page 6 · click to enlarge
Page 6

4 COREBUILDER 6000 INTELLIGENT SWITCHING SOFTWARE REVISION 8.2.0

Upgrading Your LMM or LMM+

To verify that you have an LMM+ module and not an LMM module installed:

1 Check that the module’s ejector tab is labeled “LMM+”.

2 Determine the revision of your LMM+. From the top level of the Administration Console, enter:

If you have an LMM+ at a revision earlier than 1.21 (for revision 1 modules) or 2.12 (for revision 2 modules), call 3Com Customer Service at 1-800-876-3266, option 2. 3Com will replace your LMM+ with an LMM+ at the correct revision, free of charge. (Contact 3Com Customer Service at the same number to upgrade an LMM to an LMM+. There is a fee for this upgrade.)

Release Highlights Release 8.2.0 software offers support for the following items:

I Fast Ethernet Switching Module (FESM)

I HSI Switch Engine

I Ability to administer Fast Ethernet ports

I Bridge MIB support for the FESM

I Filter MIB support

I FTP packet filter program transfers via SNMP

I Disconnecting an active telnet or rlogin session

I STP linkState changes

I CoreBuilder 6000 12-slot chassis

For more information about this release, see “What’s New at Revision 8.2.0?” on page 11.

Before You Start Before you install your new software, read all of these release notes. Carefully read “System Issues” on page 21 and “Known Problems” on page 22.

system display

Page 7 of the 3Com 6000 user manual — Updating Your System Software
Page 7 · click to enlarge
Page 7

Updating Your System Software 5

The top-level menus in your Administration Console may differ from those illustrated in these release notes depending on your level of access privilege and on the modules you have installed in your CoreBuilder chassis.

Updating Your System Software

You can install a new software version from any host that is running FTP server software. The system software is distributed for both the UNIX and the MS-DOS platforms.

The following media types are used to distribute compressed files for software releases:

I UNIX tar format 3 1/2-inch, double-sided, high-density 1.44 MB diskettes

I MS-DOS format 3 1/2-inch, double-sided, high-density 1.44 MB diskettes

To install or upgrade your system software, you must:

I Copy the software from the diskette to your UNIX or MS-DOS computer’s hard disk.

I Decompress the software.

I Load the system software from your computer’s hard disk to flash memory on the LMM+.

Details for these procedures are provided in the next sections.

You can copy system software to a computer that runs either a UNIX or an MS-DOS operating system.

Copying to the UNIX Platform

The CoreBuilder software for a UNIX system is distributed on six diskettes. Diskettes #1, #2, #3, #4 and #5 contain the CoreBuilder software. Diskette #6 contains the SNMP MIBs.

Copying System · Software to a · Hard Disk

Page 8 of the 3Com 6000 user manual — Updating Your System Software
Page 8 · click to enlarge
Page 8

6 COREBUILDER 6000 INTELLIGENT SWITCHING SOFTWARE REVISION 8.2.0

To copy the software to a UNIX hard disk, follow these instructions.

If the directory “/usr/lp6000” does not exist on your computer, create the directory before proceeding. If your “/usr” directory is full, you can use a different directory. If you use a different directory, substitute the actual directory you use for “/usr” in this and subsequent procedures.

1 Insert diskette #1 into the disk drive. These instructions assume drive rfd0.

2 Extract the first part of the CoreBuilder software file using the following commands:

# tar xvf /dev/rfd0

3 Remove diskette #1 using the following command:

4 Insert diskette #2 into the disk drive and extract the second part of the file using the following command:

# tar xvf /dev/rfd0

5 Remove diskette #2 using the following command:

6 Insert diskette #3 into the disk drive and extract the third part of the file using the following command:

# tar xvf /dev/rfd0

7 Remove diskette #3 using the following command:

8 Insert diskette #4 into the disk drive and extract the fourth part of the file using the following command:

# tar xvf /dev/rfd0

9 Remove diskette #4 using the following command:

10 Insert diskette #5 into the disk drive and extract the fifth part of the file using the following command:

Show 4 more labels / short text on this page
# eject · # eject · # eject · # eject
Page 9 of the 3Com 6000 user manual — OR
Page 9 · click to enlarge
Page 9

Updating Your System Software 7

# tar xvf /dev/rfd0

11 Remove diskette #5 using the following command:

The following files should be in your /usr/lp6000 directory:

I README1

12 Use this script to decompress and restore the split file (lp600000, lp600001, lp600002, lp600003, and lp600004):

This procedure creates the uncompressed file . See the README1 file for file size and checksum information.

Copying to the MS-DOS Platform

The CoreBuilder software for an MS-DOS system is distributed on four diskettes. This software must be installed using either the Windows 95 or the Windows NT operating system.

3Com recommends that you exit from all Windows programs before running this Setup program.

Installing on a Windows 95 or Windows NT Computer. To copy software to an MS-DOS host computer’s hard disk using Windows 95 or Windows NT, take these steps:

1 Insert diskette #1 into a disk drive. These instructions assume drive a.

2 For Windows 95, click the Windows 95 START button and choose the Run command.

OR

For Windows NT, choose Run from the File menu.

The system displays the Setup screen, with the system software name, and the Setup dialog box.

Show 7 more labels / short text on this page
# eject · I lp600000 · I lp600001 · I lp600002 · I lp600003 · I lp600004 · I restore_lpx
Page 10 of the 3Com 6000 user manual — Loading System Software on the LMM+
Page 10 · click to enlarge
Page 10

8 COREBUILDER 6000 INTELLIGENT SWITCHING SOFTWARE REVISION 8.2.0

3 At the command line in the Setup dialog box, enter a:setup and click OK.

A Welcome screen appears. The system prompts you to continue or to cancel the installation. To continue, click Next. To cancel the installation and exit the Setup program, click Cancel.

You are guided through the rest of the installation procedure by the Install Shield Wizard.

This procedure creates a file folder called lp6000, which contains:

I README.text

Loading System Software on the LMM+

Before loading the system software on the LMM+, verify that the host computer, which has a copy of the updated system software, is connected to the CoreBuilder 6000 system.

You can load the system software into flash memory while the system is operating. You do not need to bring the system down. After the flash install is completed, a quick reboot puts the newly loaded software to use.

If you are loading software from a PC host, the FTP server software must be running on the PC before you begin this procedure.

Loading 8.2.0 software into flash memory takes approximately 10 to 15 minutes to complete, depending on your network load.

To load the new software:

1 From the top level of the Administration Console, enter:

The system prompts you for the Host IP address, Install file name, User name, and Password. The current default values are displayed in brackets [ ]. Press [Return] to accept the default values. The Password field does not display what you enter.

2 Next to Host IP address, enter the IP address of the host machine (such as a Sun workstation or PC) from which you are installing the software.

In the example in step 5, the IP address of the host is 192.9.200.96.

I IMAGE folder · I MIBS folder · system softwareUpdate

Page 11 of the 3Com 6000 user manual — Loading System Software on the LMM+
Page 11 · click to enlarge
Page 11

Loading System Software on the LMM+ 9

3 Next to Install file pathname, enter the complete path and filename.

For MS-DOS system syntax, you must precede the full path with a forward slash ( / ). For example, if you are loading software from an MS-DOS host, enter the following command at the Install file pathname prompt:

/c:\lp6000\lp6000

4 Next to User name, enter your user name.

5 Next to Password, enter your password. You must enter a value for this field, although the field does not display what you enter.

Example of the software installation prompts on a UNIX system:

Host IP address [192.9.200.14]192.9.200.96 Install file pathname [/usr/lp6000/lp6000]: User name: ronnyk Password:

Programming flash memory block 1 of 24... Programming flash memory block 2 of 24... Programming flash memory block 3 of 24 Programming flash memory block 24 of 24...

After the software is loaded, you receive this message:

Installation complete.

If the CoreBuilder executable software image stored in flash memory is corrupted (for example, when a power failure occurs while you are updating software), contact 3Com Technical Support. See “Technical Support” on page 30.

6 To reboot the system to use the newly loaded software, enter:

You are prompted with the following message:

Are you sure you want to reboot the system (y/n) [y]:

7 At the prompt, enter y for (yes).

system reboot

Page 12 of the 3Com 6000 user manual — User Documentation
Page 12 · click to enlarge
Page 12

10 COREBUILDER 6000 INTELLIGENT SWITCHING SOFTWARE REVISION 8.2.0

You are now ready to configure management access for your system. See the CoreBuilder 6000 Getting Started Guide.

User Documentation

This version of software is compatible with the documentation listed here. Some of this documentation may be available on CD-ROM. These release notes describe any changes and additions to this documentation.

I LANplex 6000 Getting Started

I LANplex 6000 Control Panel User Guide

I LANplex 6000 Operation Guide

I LANplex 6000 Administration Console User Guide

I LANplex 6000 Command Quick Reference (folded card)

I LANplex 6000 Extended Switching User Guide

The Extended Switching User Guide ships with Extended Switching software.

Individual modules ship with their installation guides:

I LMM Plus (LANswitching Management Module Plus) Installation Guide

I FCM (FDDI Concentrator Module) Installation Guide

I ESM (Ethernet Switching Module) Installation Guide

I EFSM (Ethernet/FDDI Switching Module) Installation Guide

I TRSM (Token Ring Switching Module) Installation Guide

I TMM Fast Ethernet (Tri-Media Module) Installation Guide

I FDDI Switching Module (FSM) Guide

I Fast Ethernet Switching Module (FESM) Guide

Page 13 of the 3Com 6000 user manual — What’s New at Revision 8.2.0?
Page 13 · click to enlarge
Page 13

What’s New at Revision 8.2.0? 11

What’s New at Revision 8.2.0?

This section describes the new features, software enhancements, and corrections implemented at this release.

New Features The following features have been added at this release.

Support for the Fast Ethernet Switching Module (FESM)

The Fast Ethernet Switching Module (FESM) provides high-function switching of traffic among Fast Ethernet workstations and subnetworks over the multigigabit high-speed interconnect (HSI) bus of the CoreBuilder 6000 system.

The FESM module is available in two configurations:

I Eight 100BASE-TX ports using RJ-45 connectors

These ports support connections to unshielded twisted pair (UTP) Category 5 media.

I Six 100BASE-FX ports using SC connectors

These ports support connections to multimode fiber media.

The FESM automatically learns the MAC-layer addresses of workstations on attached subnetworks and forwards packets to their appropriate destinations. When used with CoreBuilder Extended Switching software, the FESM also supports routing between attached subnetworks. In addition, the FESM fully complies with the IEEE 802.1d bridging standard.

The FESM requires CoreBuilder 6000 software revision 8.2.0 or greater. This software, in turn, requires that one of the following LMM+ versions be installed in system slot 1:

I Revision 1.21 or greater of the revision 1 LMM+

I Revision 2.12 or greater of the revision 2 LMM+

Page 14 of the 3Com 6000 user manual — HSI Switch Engine
Page 14 · click to enlarge
Page 14

12 COREBUILDER 6000 INTELLIGENT SWITCHING SOFTWARE REVISION 8.2.0

To verify that you have an LMM+ module and not an LMM module installed:

1 Check that the module’s ejector tab is labeled “LMM+”

2 Determine the revision of your LMM+. From the top level of the Administration Console, enter:

To upgrade your LMM or LMM+, see “Upgrading Your LMM or LMM+” on page 4.

You can combine the Fast Ethernet Switching Module (FESM) and FDDI Switching Module (FSM) into a multiboard high-speed interconnect (HSI) switch engine. An HSI switch engine is a combined set of FSMs or FESMs which, when inserted into the HSI bus according to specific configuration rules, operates as a single switch. Multiple FSMs and FESMs in a single HSI switch engine bridge the combined set of external ports on all modules in that switch engine. Additionally, as you add a new module to an existing HSI switch engine, the system automatically adds configuration information for the existing HSI switch engine to the new module. You must manually configure any port-specific information, however.

Ability to Administer Fast Ethernet Ports

New menus on the Administer menu allow you to administer Fast Ethernet ports on the Fast Ethernet Switching Module (FESM) and the Tri-Media Module (TMM-FE). You can now configure Fast Ethernet ports to support:

I Intelligent flow management (IFM)

Full-duplex operation. By default, FESM and TMM Fast Ethernet ports operate in half-duplex mode. In this mode, data flows through the port in only one direction at a time. If you change this operating mode to full-duplex, the port transmits and receives data through two separate channels.

system display · HSI Switch Engine · I Full-duplex operation

Page 15 of the 3Com 6000 user manual — HSI Switch Engine
Page 15 · click to enlarge
Page 15

What’s New at Revision 8.2.0? 13

Full-duplex mode eliminates both the link’s collision domain and the need for collision detection. As a result, full-duplex point-to-point links can be much longer than half-duplex links.

To configure a port for full-duplex operation:

The top-level menus in this chapter change based on you level of access and on the modules installed in your CoreBuilder system.

1 From the top level of the Administration Console, enter:

summary detail ±fastEthernet

fddi tokenring bridge ip snmp analyzer script logout

You receive a prompt similar to the following:

Select slot(s) (10-12|all):

This prompt indicates that the CoreBuilder 6000 system contains configurable Fast Ethernet ports in slots 10, 11, and 12.

2 Enter the number(s) of the slot(s) that contain ports you want to set to full-duplex mode:

For each slot you entered, the system prompts you for specific port numbers:

Select Ethernet port(s) (1-8,all):

3 Enter the number(s) of the port(s) that you want to configure:

The system displays this message:

The CoreBuilder 6000 system does not support automatic negotiation of duplex mode between devices. You must configure any device attached to this port for the same duplex mode.

4 Enter y for yes, n for no.

You receive the prompt to select each port’s duplex mode:

Enter new value (full, half) [half]:

Show 8 more labels / short text on this page
Top-Level Menu · system ±ethernet · ethernet fastEthernet duplexMode · s · ±duplexMode · ifm · label portState · 1,2,5-7
Page 16 of the 3Com 6000 user manual — HSI Switch Engine
Page 16 · click to enlarge
Page 16

14 COREBUILDER 6000 INTELLIGENT SWITCHING SOFTWARE REVISION 8.2.0

5 Enter full to set the port to full-duplex mode or half to set the port to half-duplex mode.

Default The port’s current setting is indicated within square brackets. To select this default, press [Return]. This action leaves the port unchanged.

6 Repeat steps 4 and 5 to configure all the selected ports in all the selected slots.

Changing the mode to full-duplex disables collision detection on these ports.

Intelligent Flow Management (IFM). Intelligent flow management (IFM) is a congestion control mechanism built into the CoreBuilder system. You should implement IFM on any Fast Ethernet port that has a high volume of traffic. By default, IFM is enabled on CoreBuilder module ports.

Congestion is caused when one or more devices send traffic to an already congested port. If the port is connected to another CoreBuilder system or to an end-station, IFM minimizes packet loss and inhibits the sending device from generating more packets until the period of congestion ends.

Intelligent flow management is supported only on half-duplex ports. It is automatically disabled when a port is configured for full-duplex. 3Com recommends disabling IFM on network segments connected to repeaters.

summary detail ±fastEthernet

To apply IFM to a half-duplex Fast Ethernet port:

fddi tokenring bridge ip snmp analyzer script logout

1 From the top level of the Administration Console, enter:

You receive a prompt similar to the following:

Select slot(s) (10-12|all):

This prompt indicates that the CoreBuilder 6000 system contains configurable Fast Ethernet ports in slots 10, 11, and 12.

Show 6 more labels / short text on this page
Top-Level Menu · system ±ethernet · s · duplexMode ±ifm · label portState · ethernet fastEthernet ifm
Page 17 of the 3Com 6000 user manual — Bridge MIB Support for the FESM
Page 17 · click to enlarge
Page 17

What’s New at Revision 8.2.0? 15

2 Enter the number(s) of the slot(s) that contain ports you want to set to IFM mode:

For each slot you entered, the system prompts you for specific port numbers:

Select Ethernet port(s) (1-8,all):

3 Enter the number(s) of the port(s) that you want to configure:

You receive the prompt to enable or disable IFM mode for each selected port:

Enter new value (disabled, enabled) [disabled]:

4 Enter enabled to set the port to IFM mode or disabled to deactivate IFM for the port.

Default The port’s current setting is indicated within square brackets. To select this default, press [Return]. This action leaves the port unchanged.

5 Repeat step 4 to configure all the selected ports in all the selected slots.

Bridge MIB Support for the FESM

FESM support has been added to the Bridge MIB.

Support for the Filter MIB (address group, port group, and bridge packet filter program) has been added.

FTP Packet Filter Program Transfers via SNMP

You can now use File Transfer Protocol (FTP) to transfer a user-defined packet filter program from a remote server to a CoreBuilder 6000 switching module through the SNMP lpsFtTable MIB.

1,2,5-7 · Filter MIB Support

Page 18 of the 3Com 6000 user manual — Disconnecting an Active telnet or rlogin Session
Page 18 · click to enlarge
Page 18

16 COREBUILDER 6000 INTELLIGENT SWITCHING SOFTWARE REVISION 8.2.0

Disconnecting an Active telnet or rlogin Session

Modifications to the telnet and rlogin features of the CoreBuilder 6000 system allow you to preempt users by forcing a disconnection. This administrative feature requires you to use the system Administer-level password at the Administration Console.

The rlogin usage is identical to the telnet usage. Substitute rlogin wherever you see telnet.

Implementation. When you attempt to use the telnet command to enter a system that is being used by another telnet connection, the system displays:

Sorry, this system is engaged by another telnet session. Host IP address: xxx.xxx.xxx.xxx

Logout the other telnet session? (Y/N) y Enter Password: administer-level-password

The first telnet session is disconnected and the system displays:

LOGGING OUT the other telnet session.

You can then connect in the usual manner.

If you enter an incorrect password, the system displays:

Incorrect password. Disconnecting.

The system automatically disconnects after it receives three incorrect attempts at the administer-level password.

If you respond n to the request to disconnect, your session disconnects and the original connection remains established. The system displays:

If you enter y at the Logout the other telnet session? prompt and it is not accepted, it is probably because of the telnet configuration on the UNIX host. To force the system to accept your response to the prompt, follow these steps:

1 Escape to the telnet session by pressing Ctrl+}

Disconnecting

Page 19 of the 3Com 6000 user manual — OR
Page 19 · click to enlarge
Page 19

What’s New at Revision 8.2.0? 17

2 Set the cr/lf option by entering either of these commands:

OR

Press Enter to redisplay the prompt. Your response should now be accepted.

The linkState of a port is now a factor in determining the Spanning Tree port state. This change helps prevent bridge loops when making network connections to previously inactive ports.

The bridge port summary and the bridge port detail screens include a new linkState column.

Top-Level Menu system ethernet fddi tokenring ±bridge

To display the bridge information:

display mode lowLatency ipFragmentation ipxSnapTranslation trFddiMode addressThreshold agingTime stpState stpPriority stpMaxAge stpHelloTime stpForwardDelay stpGroupAddress srBridgeNumber ±port

±summary ±detail

1 From the top level of the Administration Console, enter:

multicastLimit stpState stpCost stpPriority srRingNumber srHopLimit address

ip snmp analyzer script logout

OR

The system prompts you for slot number(s).

2 Enter the number(s) of the slot(s) or all to view port parameters for all bridges in the system. The system prompts you for the port type.

3 Enter Ethernet.

The system prompts you for port number(s).

4 Enter the number(s) of the port(s) or all to view port parameters for all ports on the bridge.

Sample screen showing the display after the changes:

port rxFrames rxDiscards txFrames FDDI 1 0 0 0 Fast Ethernet 1 0 0 0 Ethernet 2 59243130 0 866810375 port portId fwdTransitions FDDI 1 0x8001 0

Show 6 more labels / short text on this page
set crlf · toggle crlf · STP linkState Changes · bridge port summary · bridge port detail · packetFilter
Page 20 of the 3Com 6000 user manual — CoreBuilder 6000 12-Slot Chassis
Page 20 · click to enlarge
Page 20

18 COREBUILDER 6000 INTELLIGENT SWITCHING SOFTWARE REVISION 8.2.0

Fast Ethernet 1 0x8002 0 Ethernet 2 0x8003 0 port stp linkState state FDDI 1 enabled n/a forwarding Fast Ethernet 1 enabled down disabled Ethernet 2 enabled up forwarding

I The linkState up or down applies to Ethernet and Fast Ethernet ports, not FDDI ports, and only when the stpState for the bridge is enabled. If the stpState on the Bridge menu is disabled, the State for the port remains in forwarding state.

I When the bridge port is in the Removed state, the State remains in forwarding state.

I If STP is disabled on an individual port, the State remains disabled.

Table 1 describes the port states and how they relate to the linkState. This table is valid only when the stpState for the bridge is enabled.

Table 1 Port States When stpState Is Enabled

If STP is and linkState is Then Port State is

enabled up blocking or forwarding*

*The Port State is either blocking or forwarding. The final state depends on the Spanning Tree configuration of the network.

CoreBuilder 6000 12-Slot Chassis

The CoreBuilder 6000 12-slot chassis is the latest generation of the CoreBuilder 6000 chassis. This chassis and the 8.2.0 software release allow you to remove and replace the power supplies and fan trays in case of failure.

Show 5 more labels / short text on this page
enabled down disabled · disabled up disabled · disabled down disabled · removed up forwarding · removed down forwarding
Page 21 of the 3Com 6000 user manual — CoreBuilder 6000 12-Slot Chassis
Page 21 · click to enlarge
Page 21

What’s New at Revision 8.2.0? 19

Hot-swappable Power Supplies. You can remove and replace either of the two power supplies at the back of the chassis. Turning off one of the power supplies generates a sound, and the control panel LCD displays Input Failure. The LED of each power supply lights green when the power supply is running correctly. If the power supply fails, the system generates a sound and the power supply LED does not light.

To remove a faulty power supply and replace it with a new unit, follow these steps:

1 Turn off the power supply according to the safety and removal procedures in the Installation Guide that is shipped with the new power supply. The system control panel displays the following message (where n designates power supply 1 or power supply 2):

Power Supply nInput Failure

2 Remove the power supply. The system generates a sound, and the system control panel displays the following message:

Power supply n extracted.

3 Insert the new power supply, following the instructions and safety warnings in the Installation Guide that comes with the new power supply. The system displays this message:

This message is immediately overwritten with:

4 Turn on the power supply. The system generates a sound and the system control panel displays:

Inserted · Input Failure · Input restored

Page 22 of the 3Com 6000 user manual — CoreBuilder 6000 12-Slot Chassis
Page 22 · click to enlarge
Page 22

20 COREBUILDER 6000 INTELLIGENT SWITCHING SOFTWARE REVISION 8.2.0

Power Supply Warning Messages. This release of system software now displays these power supply warning messages when appropriate:

The power supply +5-volt input has failed.

The power supply +12-volt input has failed.

The power supply +12-volt input is restored.

The power supply +5-volt input is restored.

I Power Supply Over Temp

One of the power supplies has exceeded the allowable temperature of 90 degrees C.

SNMP Traps. When you insert and extract either of the power supplies, the system generates SNMP traps.

Hot-swappable Fans. You can remove and replace either of the two fans at the back of the chassis. When you remove a fan tray, the system generates a sound and the control panel displays the following message:

Insert the new fan following the instructions and safety messages in the Installation Guide that comes with the new fan. The fan begins to function immediately after you install it. The system control panel displays this message:

Show 6 more labels / short text on this page
I +5V Failure · I +12V Failure · I +12V Restored · I +5V Restored · Fan Failure · Fan Restored
Page 23 of the 3Com 6000 user manual — System Issues The following system issues are identified at this release:
Page 23 · click to enlarge
Page 23

System Issues The following system issues are identified at this release:

I If the FESM diagnostic fails on a system power-up, the error message you find will look similar to the following message. You then need to reboot the system.

FAIL -- Test[ 3 ]: FSM/FESM Powerup Diags ( MAC Test ) failed. -- B3 in slot 10 FAILED diagnostics Diagmgr : Diagnostics failed for slot 10, error 2

I The system software does not support hot-swapping of Fast Ethernet Switching Module (FESMs) and FDDI Switching Modules (FSMs).

I 3Com recommends that you hot-swap one module at a time (except FESMs and FSMs, as described in the previous System Issue). After you hot-swap a module, wait until the system completes full initialization before you install another module. One indication that initialization is complete is that the Administration Console prompt appears on the screen. Under certain circumstances, hot-swapping during initialization can cause a cold system boot, disrupting bridging.

I Roving Analysis is not supported on the FESM.

I When configuring Roving Analysis on an ESM, the system will accept an unknown MAC address as the analyzer port.

I The first line in a user-defined packet filter must contain the name definition for that packet filter. For example:

Name “forward IP frames” indicates that this packet filter forwards IP frames.

System Issues 21

Page 24 of the 3Com 6000 user manual — Known Problems The following software problems are identified at this release:
Page 24 · click to enlarge
Page 24

22 COREBUILDER 6000 INTELLIGENT SWITCHING SOFTWARE REVISION 8.2.0

I When installing 8.2.0 Intelligent software onto a LMM+ running 8.2.1 Extended software, and non-IP VLANs are defined, you must reset non-volatile ram immediately after installing the 8.2.0 Intelligent software into flash memory. Please enter the following command immediately after the message Installation complete is displayed to the console:

I When the first FDDI MAC address of an FSM is assigned to the backplane, FDDI ports are renumbered.

I EFSM packet filters can access packet data through byte 64 in the packet.

I When using the Administration Console to display all instances of a given MAC address in a mixed token ring and Ethernet environment, you must use the find command for both the noncanonical and canonical formats.

I If you attempt to run CoreBuilder system software 8.2.0 on an LMM+ at revision 2.11 or earlier, the system fails to reboot automatically when you turn it on.

I The Ethernet Switching Module (ESM) and the Token Ring Switching Module (TRSM) incorrectly report transmit filter statistics.

I The ESM and TRSM FDDI packet filters cannot access packet data beyond byte 16 in the packet.

I VLAN statistics are not supported on the ESM.

I The ESM only supports RMON groups 1 through 4.

Known Problems The following software problems are identified at this release:

I Do not create port groups and port group filters on the FESMs or FSMs.

I The FESM and TMM-FE rxFrames, txFrames, rxBytes, and txBytes statistics might report inaccurate values.

I The FESM FDDI MAC rxFrames, txFrames, rxBytes, and txBytes statistics might report inaccurate values.

I If you attempt a warm reset, a cold reset may occur.

I The system nvData save procedure fails if it occurs at the same instant when a MAC address is learned or aged out of the slot’s MAC address table.

system nvdata reset

Page 25 of the 3Com 6000 user manual — Known Problems
Page 25 · click to enlarge
Page 25

I The NVRAM conversion for SNMP traps does not adjust correctly after installing LANplex software revision 8.2.1, verify that the appropriate traps are enabled.

I An NVDATA save procedure fails if it occurs at the same instant when a MAC address is learned or aged out of the slot’s MAC address table.

I Performing a manual system nvData restore causes configurations to be restored to slots that have been specified not to restore.

When you are restoring nvData, the system proposes a method of restoration based on restoration rules. You are prompted to load the proposal. Entering yes restores the system nvData as proposed. Entering no displays the saved configuration for you to load manually.

I Changing the port speed or port mode before setting a system baseline on the TRSM might cause incorrect token ring port and bridge port statistics.

I If both the Ethernet and the FDDI interfaces have the same class of IP address, their subnet masks must be the same, although the Administration Console allows you to enter different subnet masks for these interfaces. If you do enter different subnet masks, however, the system fails when you attempt to remove one of the interfaces.

In the following example, the FDDI and the Ethernet interfaces both have class B IP addresses, and both have the same subnet mask:

FDDI interface 158.101.101.1 Subnet mask255.255.0.0 Ethernet interface: 158.101.20.1 Subnet mask: 255.255.0.0

Do not assign different subnet masks to these interfaces (such as 255.255.255.0 and 255.255.0.0) if they have the same class of IP address.

I Some bridge port statistics are not counted on the TRSM’s token ring ports. The following statistics report 0 in the bridge port display for token ring ports on the TRSM - rxDiscard, rxFloodUcasts, rxForwardMcasts, rxForwardUcasts.

I When running large scripts, you might receive the following message after the script is complete:

Received ftpCommand Quit not completed errno 421

To be sure that the script has run completely and successfully, check to see that the last two commands in the script have been completed successfully.

Known Problems 23

Page 26 of the 3Com 6000 user manual — Known Problems
Page 26 · click to enlarge
Page 26

24 COREBUILDER 6000 INTELLIGENT SWITCHING SOFTWARE REVISION 8.2.0

I You cannot modify the port specification of an IP interface defined on the LMM+ module. To modify the port specification, remove the IP interface and define it again.

I When you install software using the SNMP lpsFt MIB, the installation fails unless you specify a user password.

I When you install software from an unreachable device using the SNMP lpsFt MIB, the system reports the incorrect status “statusFileNotFound”, rather than the correct status “statusRemoteUnreachable”.

I When you install software using the SNMP lpsFt MIB and you specify an invalid username and password pair, the system reports the incorrect status ”statusFileNotFound”, rather than the correct status “statusUserAuthFailed”.

I ESM Arp table displays invalid hardware address.

Page 27 of the 3Com 6000 user manual — SNMP MIB Files
Page 27 · click to enlarge
Page 27

SNMP MIB Files 25

SNMP MIB Files SNMP MIB files are shipped with the CoreBuilder system software as ASN.1 files on one of the software diskettes. Copies of ASN.1 files are provided for each of the supported compilers described at the end of this section.

Supported Versions The SNMP MIB file names and the currently supported version of each MIB are listed here:

I bridge.mib — Bridge MIB, RFC 1493

I ethernet.mib — Ethernet MIB, RFC 1398

I filter.mib

I if.mib — If MIB, RFC 1573

I lpsFt.mib

I fddiSmt7.mib — FDDI SMT 7.3 MIB, RFC 1512

I lp.mib — CoreBuilder Systems MIB, version 1.3.0

I lpOpFddi.mib — CoreBuilder Optional FDDI MIB, version 1.2.1

I mib2.mib — MIB-II, RFC 1213

I srbridge.mib —Source Routing MIB RFC1525

Compiler Support ASN.1 MIB files are provided for each of the MIB compilers listed in this section. Any warnings or exceptions related to a compiler are listed with it.

I SMIC (version 1.0.9)

I MOSY (version 7.1)

For the MIB file lpOpFddi.mib, the MOSY compiler reports warnings for counter names that do not end in “s”. This report has no effect on the output produced by the MOSY compiler.

I HP Openview (version 3.1)

Page 28 of the 3Com 6000 user manual — SNMP MIB Files
Page 28 · click to enlarge
Page 28

26 COREBUILDER 6000 INTELLIGENT SWITCHING SOFTWARE REVISION 8.2.0

I mib2schema (with SunNet Manager version 2.0)

The MIB file fddiSmt7.mib produces the following warning messages when compiled using mib2schema:

Translating

fddimibMACSMTIndex fddimibMACIndex Translation Complete. Schema file in “fddiSmt7.mib.schema” Oid file in “fddiSmt7.mib.oid”

These warning messages have no effect on the ability of SunNet Manager to use the schema file generated with SunNet Manager versions 2.0 or later.

Page 29 of the 3Com 6000 user manual — Revision History
Page 29 · click to enlarge
Page 29

Revision History Table 2 provides a brief description of the previous releases of the CoreBuilder 6000 Intelligent Switching software.

Table 2 Revision History for CoreBuilder™ 6000 Intelligent Switching Software

Revision Number Description of Release

8.0.2 Updated system diagnostics

8.0.1 Fixes for several problems that existed in Revision 8.0.0

8.0.0 New features:

I Support for the FDDI Switching Module (FSM)

I Support for the EFSM TP-DDI Module

I State field added to interface display

I System menu item upTime added

I New FDDI MAC statistic rxErrors

I New fields added to FDDI MAC summary and detail displays

I Configurable Source Route hop count limit

I CoreBuilder MIB support updates

I Bridge MIB support added for the FSM

I New If MIB added

7.0.0 New features:

I Support for the Tri-Media Module (TMM)

I Support for the IBM Spanning Tree Protocol on the Token Ring Switching Module (TRSM)

I Support for configuring the Spanning Tree Protocol (STP) group address

I Support for token ring and Source Routing MIBs

I Support for telnet and rlogin session termination after a user-specified time interval

I Support for 64 IP static routes on each EFSM

6.0.0 New feature:

I Support for the Token Ring Switching Module (TRSM)

Revision History 27 · (continued)

Page 30 of the 3Com 6000 user manual — Revision History
Page 30 · click to enlarge
Page 30

28 COREBUILDER 6000 INTELLIGENT SWITCHING SOFTWARE REVISION 8.2.0

Table 2 Revision History for CoreBuilder™ 6000 Intelligent Switching Software

Revision Number Description of Release

5.0.0 New feature:

I Support for LMM+ management module

4.3.0 New features:

I IPX Snap Translation Option

I Support for EFSM Type 1, 10BASE-2 (BNC) module

I Support for EFSM Type 2, 10BASE-T (RJ-45) and 10BASE-FL (FOIRL) modules with SAS FDDI (MIC) ports

I Support for Single Mode Fiber (SMF) on the FCM module

I Support for the 48-volt power supply

4.1.0 New features:

I Support for EFSM Type 1, 10 BASE-T (RJ-21, Telco), 10BASE-T (RJ-45), and 10BASE-FL (FOIRL)

I Roving Analysis for Ethernet network monitoring on the ESM and EFSM modules

I Support for Multiple SNMP Agents

I FDDI Backplane Paths

I Enhanced Administration Console User Guide

3.1.9 Maintenance release

3.1.7 Maintenance release

MIB support removed:

I Ethernet MIB attributes, requestedEnabledPaths and enabledPaths, no longer supported

I CoreBuilder SNMP MIB traps, lpBridgePortAddressLearnedEvent and lpBridgePortAddressForgottenEvent, no longer supported

3.1.5 New feature:

I Support for the SMT MIB path attribute Ring Latency

I UDP Helper · I Multistation Mode · (continued)

Page 31 of the 3Com 6000 user manual — Revision History
Page 31 · click to enlarge
Page 31

Table 2 Revision History for CoreBuilder™ 6000 Intelligent Switching Software

Revision Number Description of Release

3.1.4 New features:

I ESM 10BASE-2 (BNC) media support

I IP advertisement address configuration support

3.1.1 New features:

I IP routing functionality

I TP-DDI media support

I Nonvolatile data save and restore functionality

3.0.1 New feature:

I Baselining of Ethernet and FDDI statistics functionality

Revision History 29

Page 32 of the 3Com 6000 user manual — Technical Support
Page 32 · click to enlarge
Page 32

30 COREBUILDER 6000 INTELLIGENT SWITCHING SOFTWARE REVISION 8.2.0

Technical Support 3Com provides easy access to technical support information through a variety of services. This appendix describes these services.

Information contained in this document is correct at time of publication. For the very latest, we recommend that you access 3Com Corporation’s World Wide Web site as described below.

If additional assistance is required, contact your network supplier. Many suppliers are authorized 3Com service partners who are qualified to provide a variety of services, including network planning, installation, hardware maintenance, application training, and support services.

When you contact your network supplier for assistance, have the following information ready:

I Diagnostic error messages

I A list of system hardware and software, including revision levels

I Details about recent configuration changes, if applicable

If you are unable to contact your network supplier, see the following section on how to contact 3Com.

Support from Your · Network Supplier

Page 33 of the 3Com 6000 user manual — Support from 3Com
Page 33 · click to enlarge
Page 33

Support from 3Com If you are unable to receive support from your network supplier, technical support contracts are available from 3Com.

Contact your local 3Com sales office to find your authorized service provider using one of these numbers:

Regional Sales Office Telephone Number Regional Sales Office Telephone Number

3Com Corporation U.S.

353 1 820 7077

800 NET 3Com or 1 408 764 5000

81 3 3345 7251

3Com Latin America Argentina Brazil Chile Colombia Mexico Peru Venezuela

3Com ANZA East West

54 1 312 3266 55 11 546 0869 56 2 633 9242 57 1 629 4110 52 5 520 7841 51 1 221 5399 58 2 953 8122

61 2 9937 5000 61 3 9866 8022

3Com Asia Limited China

86 10 68492 568 (Beijing) 86 21 6374 0220 Ext 6115 (Shanghai) 852 2501 1111 91 11 644 3974 62 21 523 9181 82 2 319 4711 60 3 732 7910 65 538 9368 886 2 377 5850 662 231 8151 4

Hong Kong India Indonesia Korea Malaysia Singapore Taiwan Thailand

39 2 253011 (Milan) 39 6 5279941 (Rome)

3Com Nordic AB Denmark Finland Norway Sweden

45 39 27 85 00 358 0 435 420 67 47 22 18 40 03 46 8 632 56 00

3Com Benelux B.V. Belgium Netherlands

32 725 0202 31 30 6029700

3Com Canada Calgary Montreal Ottawa Toronto Vancouver

27 11 807 4397

403 265 3266 514 683 3266 613 566 7055 416 498 3266 604 434 3266

44 131 2478558 (Edinburgh) 44 161 8737717 (Manchester) 44 1628 897000 (Marlow)

33 1 69 86 68 00

3Com GmbH Austria Czech and Slovak Republics Germany

43 1 5134323 42 2 21845 800 49 30 3498790 (Berlin) 49 89 627320 (Munich) 36 1 250 83 41 48 22 6451351 41 31 996 14 14

Show 12 more labels / short text on this page
Technical Support 31 · 3Com Ireland · 3Com Japan · 3Com Mediterraneo Italy · 3Com Middle East · 971 4 349049 · 3Com Russia · 007 095 2580940 · 3Com South Africa · 3Com UK Limited · 3Com France · Hungary Poland Switzerland
Page 34 of the 3Com 6000 user manual — Returning Products for Repair
Page 34 · click to enlarge
Page 34

32 COREBUILDER 6000 INTELLIGENT SWITCHING SOFTWARE REVISION 8.2.0

Before you send a product directly to 3Com for repair, you must first obtain a Return Materials Authorization (RMA) number. Products sent to 3Com without RMA numbers will be returned to the sender unopened, at the sender’s expense.

To obtain an RMA number, call or fax:

Country Telephone Number Fax Number

U.S.A. and Canada 1 800 876 3266, option 2 408 764 7120

Latin America 1 408 326 7801 408 764 7120

Europe, South Africa and Middle East

44 1442 438125 44 1442 435822

Outside Europe, U.S.A., Canada, and Latin America

1 408 326 7804 1 408 764 7120

Returning Products · for Repair

Ask about the 3Com 6000

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the 3Com 6000

Be the first to ask — other owners or our team will answer.

Original document

3Com 6000 manual PDF

34 pages·225 KB·Network Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…