30" (76.2 cm) 36" (91.4 cm) 42" (106.7 cm) Retractable (Pop-up) Downdraft Vent Systems


Electrical ground is required. See “Electrical requirements,” page 3. When installing downdraft vent, the cabinet drawer will need to be removed and the drawer front installed permanently to cabinet. Note: Downdraft vent is installed directly behind the cooktop. Install downdraft vent first. Downdraft vent is not approved for use in mobile homes. Cabinet construction: Downdraft vent is designed for use in a cabinet with a depth of 24" (61 cm). Some installations require a countertop deeper than 25" (63.5 cm). See chart on page 5. The maximum depth of the overhead cabinet is 13" (33 cm). Overhead cabinets installed at either side of the downdraft vent must be 18" (45.7 cm) above the cooking surface. See cooktop Installation Instructions before making any cutouts and for the minimum distance between the front edge of the countertop and front edge of cooktop. The minimum horizontal distance between the overhead cabinets is the same as the width of the installed downdraft vent. When installing a 36" (91.4 cm) or 42" (106.7 cm) retractable downdraft vent with “Create-A- Cooktop” modules, the optional support must be installed on the front of the downdraft vent. See installation steps for details.
Before you start...

others is very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to hazards that can kill or hurt you and others. All safety messages will be preceded by the safety alert symbol and the word “DANGER” or “WARNING”. These words mean:
You will be killed or seriously injured if you don’t follow instructions.
You can be killed or seriously injured if you don’t follow instructions.
All safety messages will identify the hazard, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
Proper installation is your responsibility. Make sure you have everything necessary for correct installation. It is the responsibility of the installer to comply with the installation clearances specified on the model/serial rating plate. The model/serial rating plate is located on the front of the downdraft vent above the wiring box cover. Check location where downdraft vent will be installed. The location should be away from strong draft areas, such as windows, doors and strong heating vents or fans. Before making countertop cutout, check that downdraft vent and cooktop location will clear cabinet walls, backsplash, and rear wall studs inside cabinet.

ALL OPENINGS IN THE WALL OR FLOOR WHERE RETRACTABLE DOWNDRAFT VENT IS TO BE INSTALLED MUST BE SEALED.

E. A U.L.- or C.S.A.-listed, 1/2" (12.7 mm) conduit connector must be provided at each end of the power supply cable (at the downdraft vent and at the junction box).
C. Wire sizes and connections must conform to the requirements of the National Electrical Code, ANSI/NFPA 70 — latest edition*, or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 - latest edition** and all local codes and ordinances.
F. A wiring diagram is located on the downdraft vent base above the wiring box cover.
WARNING — TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable Codes and Standards, including Fire Rated Construction. The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA),and the American Society of Heating Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. Ducted fans must always be vented to the outdoors. WARNING — To reduce the risk of fire, use only metal ductwork.
* National Fire Protection Association Batterymarch Park Quincy, Massachusetts 02269
** Canadian Standard Association 178 Rexdale Boulevard Etobicoke (Toronto), Ontario M9W 1R3
If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
Do not ground to a gas pipe.
Check with a qualified electrician if you are not sure downdraft vent is properly grounded.
Do not have a fuse in the neutral or ground circuit.
A. A 120-volt, 60-Hz, AC-only electrical supply is required on a separate 15-ampere circuit, fused on both sides of the line. A time- delay fuse or circuit breaker is recommended. The fuse must be sized per local codes in accordance with the electrical rating of the downdraft vent as specified on the model/serial rating plate located on the front of the downdraft vent above the wiring box cover.
D. This downdraft vent should be connected directly to the fused disconnect (or circuit breaker) through flexible, armored or non- metallic sheathed, copper cable. Allow some slack in the cable so the downdraft vent can be moved if servicing is ever necessary.
B. THE DOWNDRAFT VENT MUST BE CONNECTED WITH COPPER WIRE ONLY.


top trim widths 30" vent (76.2 cm) 36" vent (91.4 cm) 42" vent (106.7 cm)
27" (68.6 cm) for 30" (76.2 cm) vent 33" (83.8 cm) for 36" (91.4 cm) vent 39" (99.1 cm) for 42" (106.7 cm) vent

See cooktop manufacturer’s instructions for cooktop cutout depth and width.
A = 1/2" (12.7 mm)
min.
Use dimensions for vent system cutout location that applies to your installation.
all cutouts are for 3-1/4" x 10" (8.3 cm x 25.4 cm) vent system
Vent system cutout dimensions for internal blower models only.
Exterior mounted blower systems connect with 9" (22.9 cm) round vent. The cutout locations for this vent system will depend upon your specific installation. Locate power supply junction box at lower right hand rear corner of cabinet.
centerline of cooktop cutout

27-1/2" (69.9 cm) for 30" (76.2 cm) vent 33-1/2" (85.1 cm) for 36" (91.4 cm) vent 39-1/2" (100.3 cm) for 42" (106.7 cm) vent
1-7/8" (4.8 cm)
Some models require a countertop deeper than 25" (63.5 cm); see cutout dimensions chart below.
1/4" (6.4 mm)
1/2" (12.7 mm) min.
A = 1/2" (12.7 mm)
min.
See cutout dimensions chart below.
1/4" (6.4 mm)
centerline of cooktop cutout
3/4" (19.1 mm) max. backsplash depth
1/2" (12.7 mm) minimum
It is recommended that the cooktop and vent cutouts be drawn on the countertop before making any cutouts to avoid mistakes. See Cooktop Installation Instructions for complete cutout dimensions, location dimensions and installation details. IMPORTANT: Countertops with a bullnosed front edge are not recommended for these installations.
1/2" (12.7 mm) minimum to splashguard or
Overall depth of cooktop
B
A
H
Required min. countertop depth
F Overall width of cooktop and downdraft vent system
* Installation with vent system requires countertop and base cabinet deeper than standard 25" (63.5 cm) deep countertop and 24" (61.0 cm) deep base cabinet.

a
a
a
a
a
a
a
a
a
a
a a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
SBCCI a
a
a
Interior-mounted vent motor
Vent system requirements
Vent system installed under a concrete slab using PVC sewer pipe.
6" (15.2 cm) round metal vent
Venting system must terminate to the outside. Do not terminate the vent system in an attic or other enclosed area. Do not use 4" (10.2 cm) laundry- type wall caps Do not use plastic or metal foil vent. Vent work needed for installation is not supplied. Wall cap is Not provided with interior-mounted motor.
6" (15.2 cm) round PVC sewer pipe
6" (15.2 cm) round metal vent

6" (15.2 cm) round PVC
16" (40.6 cm) maximum 12" (30.5 cm) minimum
concrete slab 6" (15.2 cm) round PVC sewer pipe
6" (15.2 cm) round PVC coupling
6" (15.2 cm) round 90° PVC sewer pipe elbow
Tightly pack gravel or sand completely around pipe.
6" (15.2 cm) round 90° PVC sewer pipe elbow
Optional vent system installed under a concrete slab into a window well.
Determine which venting method to use. Vent system can extend through either the wall or roof. The length of vent system and number of elbows should be kept to a minimum to provide efficient performance. The size of the vent should be uniform. Do Not install two elbows together. Use duct tape to seal all joints in the vent system. Use caulking tape to seal the exterior wall or floor opening around cap. Do Not cut joist or stud. If vent cutout falls over a joist or stud, a supporting frame must be constructed. Flexible metal vent is Not recommended. If it is used, calculate each foot of flexible vent as two feet of rigid metal vent. Flexible elbows count twice as much as standard elbows. NOTE: Make sure there is proper clearance within the wall or floor before making exhaust vent cutouts. Recommended vent system length For either interior-mounted or exterior-mounted blower installations, vent system length should not exceed the maximum lengths listed in the “Maximum length of vent system” chart. (See this page for Interior-mounted vent motor; page 9 for exterior- mounted vent motor.)
Do not vent a gas cooktop into a window well.

12" (30.5 cm) minimum
6" (15.2 cm) round PVC sewer pipe
6" (15.2 cm) round metal vent
concrete slab 6" (15.2 cm) round PVC coupling
6" (15.2 cm) round sewer pipe
6" (15.2 cm) round 90° PVC sewer pipe elbow

6" (15.2 cm) min.
6" (15.2 cm) round PVC coupling
Tightly pack gravel or sand completely around pipe.
Seal the space between the outside of wall cap inlet inside of PVC coupling with caulking metal.

For best performance, use no more than three 90° elbows. If more than one elbow is used, make sure that there is a minimum of 24" (61 cm) of straight vent between any two elbows. Do Not install two elbows together. It is recommended that you use round vent instead of rectangular vent, especially if elbows are required. If rectangular vent is required, it should be transitioned to 6" (15.2 cm) round vent as soon as possible.

Determining the length of system you need: To calculate the length of system you need, add the equivalent feet for each vent piece that will be needed. See example for 6" (15.2 cm) round vent system.

over counter support arm
6 ft. (1.8 m)

2 ft. (0.6 m)
6. Move support legs down against cabinet floor. Place a level against front of downdraft vent base and adjust until downdraft vent is level vertically. Use a pencil to mark the top of each leg on downdraft vent. Then mark location of support leg mounting holes on cabinet floor. Remove downdraft vent from cutout. Drill starter holes at each mounting screw location on cabinet floor. Align top of legs with pencil marks on face of downdraft vent. Tighten screws in legs.
Maximum length = 35 ft. (8.9 m)
7. Determine which direction (down, rear, left, or right) vent will need to run from blower vent when installed in cabinet. Down venting: Downdraft vent is shipped with blower in down venting position so no modification is required. Go to Step 8. Left or right venting: a. Remove 4 hex nuts that attach blower box to downdraft vent base. Remove blower box. b. Rotate blower box 90° to left or right so that vent blower is repositioned in the direction needed. c. Reattach blower box to downdraft vent base with 4 hex nuts. Rear venting: a. Remove 4 hex nuts that attach blower box to downdraft vent base. Remove blower box. b. Note how wiring cable is installed under plastic clips inside vent base. Then carefully remove wiring cable from plastic clips. Disconnect blower wiring cable. c. Remove 6 Phillips-head screws attaching blower to blower box. Remove blower.
Excessive Weight Hazard Use two or more people to move and install downdraft vent. Failure to do so can result in back or other injury.


bracket for rear venting
Excessive Weight Hazard Use two or more people to move and install downdraft vent. Failure to do so can result in back or other injury.


d. Remove screws attaching brackets to each side of blower. Reposition brackets on blower as shown. Then reinstall screws. e. Reinstall blower in blower box with mouth of blower pointing out open side of blower box. Secure blower to blower box with 6 Phillips-head screws. NOTE: Square metal frame attached to mouth of blower must be installed for proper operation. f. Attach metal cover from parts bag over down-venting knockout in blower box. Remove rear knockout cover on back of vent base. g. Reconnect blower wiring cable. Secure wiring cable in 2 black plastic clips inside vent base.The wiring cable must be properly secured in the 2 clips (see step b.) Reattach blower box to downdraft vent base with 4 hex nuts.
When attaching undercounter bracket to underside of countertop, make sure that the screw length will not go through countertop when tightened.
microswitches behind filters.

filter or filters depending on model
Electrical Shock Hazard Disconnect power before making electrical connections. Connect ground wire to green ground screw in terminal box. Failure to do so can result in death or electrical shock.

use from your new retractable downdraft vent,
read the Use and Care Information section on
page 12. Keep Installation
Instructions and Use and Care Information close by for
easy reference.
KIRD and YKIRD MODELS ONLY NOTE: Exterior-mounted vent motor installations require exterior blower system, Part No. KPED890T, available from your dealer or authorized parts supplier.
It is recommended that you use round vent instead of rectangular vent, especially if elbows are required. If rectangular vent is required, it should be transitioned to 9" (22.9 cm) round vent as soon as possible.
Determining the length of system you need: To calculate the length of system you need, add the equivalent feet for each duct piece that will be needed. See example for 9" (22.9 cm) round vent system.
Island location



3-1/4" x 14" (8.3 cm x 35.6 cm) vent

Maximum length = 55 ft. (16.8 m)
For best performance, use no more than three 90° elbows. If more than one elbow is used, make sure that there is a minimum of 24 inches (61 cm) of straight vent between any two elbows. Do Not install two elbows together.
left vent

6. Move support legs down against cabinet floor. Place a level against front of downdraft vent base and adjust position of legs until downdraft is level vertically. Use a pencil to mark the top of each leg on face of downdraft vent. Then mark location of support leg mounting holes on cabinet floor. Remove downdraft vent from cutout. Drill starter holes at each mounting screw location on cabinet floor. Align top of legs with pencil marks on face of downdraft vent. Tighten screws in legs.
Excessive Weight Hazard Use two or more people to move and install downdraft vent. Failure to do so can result in back or other injury.
Power supply cable needed between exterior blower assembly and blower box is not provided. 9. Determine the location where the exterior blower box will be located. Cut opening in roof or wall for vent system to exterior blower. Install exterior blower.
over counter support arm
level · mark · support leg


microswitches behind filters.
filter or filters depending on model

When attaching undercounter bracket to underside of countertop, make sure that the screw length will not go through countertop when tightened.
exterior-mounted vent motor wiring
12. Remove required knockout and install conduit connector. Feed the power supply cable through the conduit connector and into wiring box. Connect the white wires together with a twist-on wire connector. Connect the black wires together with a twist-on wire connector. Attach the green (or green and yellow) ground wire to eyelet with green ground screw. Tighten the conduit connector clamp screws. Reattach the wiring box cover. Remove 4 hex nuts that attach vent box to downdraft vent box and remove box. Remove knockout and install conduit connector. Feed exterior-mounted vent motor wiring through conduit connector. Do not wire the exterior-mounted vent motor into the wiring box. It must be connected as shown. Connect the white wires together with a twist-on wire connector. Connect the black wires together with a twist-on connector. Tighten the conduit connector clamp screws. Reattach the vent box with 4 hex nuts.
Electrical Shock Hazard Disconnect power before making electrical connections. Connect ground wire to green ground screw in terminal box. Failure to do so can result in death or electrical shock.
use from your new retractable downdraft vent,
read the Use and Care Information section on
page 12. Keep Installation Instructions
and Use and Care Information close by for
easy reference.

The retractable downdraft vent system is designed to remove smoke, cooking vapors and odors from the cooktop area. For the best results, the vent should be operating before cooking is started. If you use large or tall utensils, place them on the large rear element or burner surface. A higher heat setting than normally used may be needed when the downdraft vent is operating.
Don’t leave range unattended when cooking.
Always use cookware and utensils appropriate for the type and amount of food being prepared.
Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. Before servicing or cleaning unit, switch power off at service panel and lock switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device such as a tag to the service panel.
SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
NEVER PICK UP A FLAMING PAN — You may be burned.
DO NOT USE WATER, including wet dishcloths or towels — a violent steam explosion will result. Use an extinguisher ONLY if:
You know you have a Class ABC extinguisher, and you already know how to operate it.
The fire is small and contained in the area where it is started.
Keep fan, filters and grease-laden surfaces clean.
The fire department is being called.
Always turn hood ON when cooking at high heat.
Use high range settings on range only when necessary. Heat oil slowly on low to medium setting.
You can fight the fire with your back to an exit.
Operating downdraft vent Push and hold for a few seconds the button on top of downdraft vent. This slight delay prevents raising the vent during cleaning. Retractable section of downdraft vent will rise and blower will begin to vent. Turn knob on side of downdraft vent to adjust the setting to the amount of venting you need. The knob has infinite settings. Place cooking utensils on cooking surface and turn cooking unit on. When cooking is complete, turn cooking unit off, remove utensils from cooking surface, and push button on top of retractable downdraft vent. The blower will turn off and the retractable section of the vent will return to the closed position. If a spill occurs on the cooktop that allows liquids to seep inside the downdraft, you must turn the
downdraft off immediately. It is possible to cause damage to the downdraft if water is allowed inside the downdraft while it is operating.
Filter or filters (depending on model): Frequently remove and clean the filters in the retractable section of the downdraft vent. This will improve the operating efficiency of the downdraft vent system. 1. Remove the filter(s) and clean them in the dishwasher or in a hot detergent solution. Do Not use the downdraft vent when the filter(s) is not in place. 2. Reinstall the clean filter(s), making sure that they are pushed in as far as they will go. Note: Downdraft vent will not operate if filter(s) is not in proper position. If the handle(s) is not fully locked, the vent may retract but not raise back up.

If retractable downdraft vent does not operate after clean filters have been reinstalled:

Push the filter in as far as it will go. When the filter is removed, the microswitch behind the filter is inactivated. This safety feature stops the blower and raising mechanism until the filter is properly reinstalled.
For model series KIRD & YKIRD 801, 802 30" (76.2 cm) one-piece trim: Part No. 8171304 (white) Part No. 8171305 (black) Part No. 8171306 (biscuit)
For model series GZ & YGZ 7930 30" (76.2 cm) one-piece trim: Part No. 8171300 (white) Part No. 8171301 (black)

For model series GZ & YGZ 7736
For model series KIRD & YKIRD 861, 862 36" (91.4 cm) one-piece trim: Part No. 8171310 (white) Part No. 8171311 (black) Part No. 8171312 (biscuit)

For model series KIRD & YKIRD 821, 822 42" (106.7 cm) one-piece trim: Part No. 8171316 (white) Part No. 8171317 (black) Part No. 8171318 (biscuit)