ECONOMY RANGE HOOD INSTALLATION INSTRUCTIONS
To register this
UXT2030AA UXT2036AA SERIES
product visit www.broan.com
READ AND SAVE THESE INSTRUCTIONS
! INTENDED FOR DOMESTIC COOKING ONLY. !
WARNING
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
TO REDUCE THE RISK OFINURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. 5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 6. Ducted fans must always be vented to the outdoors. 7. Do not use this range hood with an additional speed control device. 8. To reduce the risk of fire, use only metal ductwork. 9. Use with approved cord-connection kit only. 10. This unit must be grounded. TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. 2. NEVER PICK UP A FLAMING PAN - You may be burned. 3. DO NOT USE WATER, including wet dishcloths or towels - a violent stream explosion will result. 4. Use an extinguisher ONLY if: A. You know you a Class ABC extinguisher and you already know how to operate
it. B. The fire is small and contained in the area where it started. C. The fire department is being called. D. You can fight the fire with your back to an exit. *Based on “Kitchen Firesafety Tips” published by NFPA.


Drill, electric or ratchet drive 1/8" drill bit for drilling pilot holes 1-1/4" wood bit for drilling electrical wiring access hole One straight blade and one phillips head screwdriver Pliers Pencil and ruler and/or tape measure Saber saw or keyhole saw for cutting 1" x 2" wood strips to length and cutting wall or cabinet openings Caulking, metal snips, duct tape, duct (with elbows and transition, if necessary) and roof or wall cap, as required Electrical wiring and supplies of type to comply with local codes
The following materials are required only for installations on recessed bottom kitchen cabinets: Two 1" x 2" x 12" (approximate length) wood strips (pur- chase locally) Four 1-1/4" long flat head wood screws (purchase locally)

(This section for UXT2030AA, UXT2036AA, UXT3030AA, and UXT3036AA hoods only. UXT4030AA and UXT4036AA hoods skip this section and go on to "Prepare the Hood".)
In more complex ducting situations, a 3-1/4" x 10" rectangular ducting range hood (UXT3030AA and UXT3036AA hoods) can be converted to a round duct by means of a transition.

Begin planning ductwork by deciding where duct will run between the range hood and the outside. For best performance, use the shortest possible duct run and a minimum numaber of elbows. There are several choices shown - FIGS. A - F below.
FIG. A Ducting directly through the wall (for range hoods mounted on an exterior wall). Shown are two ways to duct through an outside wall. If a wall cap is used directly off the back of the hood, special care must be taken to make sure that the damper in the damper/duct connector on the hood damper in the wall cap do not interfere with each other when the hood is operating. This could result in either inadequate air delivery or backdrafts. If this condition does exist, remove the hood damper flap. Sometimes when using a wall cap it is easier to duct vertically and then use an elbow as shown FIG. B.

FIG. C. Straight up through the roof us- ing 7" round duct (for single story instal- lations - UXT2030AA and UTX2036AA only)



FIG. D. Ducting straight up through the roof using 3¼" x 10" rectangular duct. (For single story installations UXT3030AA and UXT3036AA hoods only.)
FIG. E. Ducting between the ceiling joists (for multi-story installations) or through the soffit space above the cabinets (where the soffit connects to an outside wall).
FIG. F. Straight up through the roof using 6" round duct (for single-story installations).

(UXT4030AA & UXT4036AA HOODS
ONLY)
WIRING
BOX COVER
ALUMINUM FILTER (UXT3030AA, UXT3036AA,
UXT2030AA, UXT2036AA)

PREPARE THE HOOD - CONT.


Omit STEP 1 if hood will be installed under cabinets with flush bottom.

1. (For installation on recessed bottom cabinets only) Attach a wood filler strip at each side of recessed are under cabinet. Use two 1" x 2" strips cut to length. If recess is deeper than 1" use thicker strips. Attach strips with 1-1/4'' wood screws, 3" from end end of strip. See FIG. 4. 2. Measure and mark the following (FIGS. 5A & 5B): a.) Electrical wiring opening in wall or cabinet. b.) Duct opening in wall or cabinet. (UXT2030AA, UXT2036AA, UXT3030AA, and UXT3036AA ONLY)

UXT2030AA UXT2036AA

PREPARE THE INSTALLATION LOCATION - CONT.

(This section for UXT2030AA, UXT2036AA, UXT3030AA, and UXT3036AA hoods ony. UXT4030AA and UXT4036AA hoods skip this section and go on to "Install Range Hood".)
larger than duct size being used. Run ductwork down to hood location. Leave 3/4" of duct projecting above roof surface on high side.
NOTE These instructions will follow plans made on Page 2. Start at the exterior and run ductwork back to the range hood. For best possible performance, use the shortest possible duct run and a minimum number of elbows. Do not vent a range hood into an attice space. A buildup of grease in the attic could become a fire hazard. Use only metal ductwork. DO NOT USE PLASTIC DUCT. Assemble duct run securely so that in case of a grease fire on the range, the fire will be contained inside metal ductwork. Tape all duct connections.
Trim duct parallel to roof pitch and seal all around duct with roof cement.
Carefully trim shingles and slide back of roof sheet under shingles. Nail roof sheet to roof under shingles at top two comers and two sides. Nail sheet directly to roof in four places at bottom.
Using roof cement, seal all nail heads and shingles which were cut or lifted. Do not seal bottom edge of roof sheet.

saw to to cut hole slightly larger than duct size used so that duct will line up easily with damper/duct connector on hood. Install casing strips if cap will be installed on siding. Attach required amount of duct to wall cap and run duct back to hood. Fasten cap to wall and caulk well.




(FIG. 10) c.) Damper/duct connector slides into ductwork.
(UXT3030AA, UXT3036AA, UXT4030AA, and UXT4036AA.



SWITCHES The fan and light are each controlled by a rocker switch. The light switch has two positions, "ON" AND "OFF". The fan switch has three positions - "HIGH", "LOW" and "OFF". ("OFF" is the middle position.)
FAN ASSEMBLY Remove filter. Remove two screws holding motor bracket to range hood, and unplug fan assembly. Be careful not to allow fan assembly to drop when screws are removed. (FIG. 15)
FILTERS UXT3030AA, UXT3036AA, UXT2030AA, and UXT2036AA Hoods Only: Remove aluminum filter by turning filter retainer to one side. (FIG. 13) Filter should be washed once a month in a hot detergent solution. Aluminum filters are dishwasher safe. when installing filter, make sure that filter slides under retaining tabs on back of fan housing. Turn filter retainer so that arrows on retainer point toward front and back of hood.


CLEANING Clean your hood with a mild detergent suitable for painted surfaces. DO NOT USE ABRASIVE CLOTH, STEEL WOOL PADS OR SCOURING POWDERS.
Fan assembly may be vacuumed. Fan assembly is lifetime lubricated, and never needs oiling.
UXT4030AA and UXT4036AA Hoods Only: The UXT4030AA and UXT4036AA hoods are equipped with a ductfree filter. Remove filter by turning filter retainer to one side. (FIG. 13). The ductfree filter is not washable, and will last up to twelve months with normal use. Replace the filter when colored side becomes noticeably dirty or discolored. When installing filter, make sure that filter slides under retaining tabs on back of fan housing. MAKE SURE THAT COLORED SIDE OF FILTER IS NEXT TO FAN WHEN FILTER IS INSTALLED. Turn filter retainer so that arrows on retainer point toward front and back of hood.

Service parts for your range hood are shown (with part numbers). List the hood model number (on spec label located on inside of hood) and the part numbers of all parts being ordered.


Hood
Only
Ductfree
Hood
Only
* Standard hardware. May be purchased locally. ** Not shown.

Warranty
Limited One Year Warranty -
Parts and Labor For one (1) Year from the original retail purchase date, any part that fails in normal home use will be repaired or replaced free of charge.
authorized by the manufacturer or an authorized servicer. c. Misuse, abuse, accidents, unreasonable use, or acts of God. d. Incorrect electric current, voltage, electrical and/or gas supply. e. Improper setting of any control.
Canadian Residents The above warranties only cover an appliance installed in Canada that has been certified or list- ed by appropriate test agencies for a compliance to a National Standard of Canada unless the appliance was brought into Canada due to trans- fer of residence from the United States to Canada.
metal ducting must be used. b. Instruct the user on the proper use of the product. c. Transport the appliance to and from the servicer.
The specific warranties expressed above are the ONLY warranties provided by the manufacturer. These warranties give you specific legal rights, and you may also have other rights which vary from state to state.
CUSTOMER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR AS PROVIDED HEREIN. IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW. MAYTAG CORPORATION SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS, SO THESE EXCLUSIONS OR LIMITATIONS MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS, WHICH VARY STATE TO STATE OR PROVINCE TO PROVINCE.
First see the Troubleshooting section in your Use and Care Guide or call the dealer from whom your appliance was purchased or call Maytag Services, LLC, Customer Assistance at 1-800-688-9900 USA and 1-800-688-2002 Canada to locate an authorized servicer.
a. Your name, address and telephone number. b. Model number and serial number. c. Name and address of your dealer or servicer. d. A clear description of the problem you are having. e. Proof of purchase (sales receipt).
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.