Part No. 626788/883345 Rev. A








is very important. We have provided many important safety

messages in this manual and on your appliance. Always read and obey all safety messages. q


This is the safety alert symbol. This symbol alerts you to hazards that can kill or hurt you and others. All safety messages will be preceded by the safety alert symbol and the word “DANGER” or “WARNING”. These words mean:





You will be killed or seriously injured if you don’t follow instructions.



You w be killed or seriously injured if you don’t follow instructions. All safety messages will identify the hazard, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.



back v&t (RH2300 series only)



RH2000 and RH2300 series vent hoods can be used for vented installations only.
Proper installation is your responsibility. Make sure you have everything necessary for correct installation. It is the responsibility of the installer to comply with the clearances specified.


RH2600 series vent hoods can be used for non-vented (recirculating) installations only. A n A 115-volt, 60-Hz, AC-only, fused electrical supply is required. The total ampere load used, including the range hood, must not exceed 90% of the rated capacity of the circuit. The ampere rating of the range hood is located on the model/serial rating plate located on the side cover of the motor housing.

Check the location where the range hood will be installed. The location should be away from strong draft areas, such as windows, doors, and strong heating vents.






Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. Before servicing or cleaning unit, switch power off at service panel and lock switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device such as a tag to the service panel

. compass or 7” l l- l/4” drill bit circle template l pencil

B w The range hood must be connected with copper wire only.

l pliers 9 ruler
l level l caulking gun . Phillips screwdriver l saber saw


l metal snips l keyhole saw
l drill . duct tape

w n The range hood should be connected directly to the fused disconnect (or circuit breaker) box through flexible armored or nonmetallic sheathed copper cable. A U.L.-listed strain relief must be provided at each end of the power supply cable. Wire sizes (COPPER WIRE ONLY) and connections must conform with the rating of the appliance as specified on the model/serial rating plate.

The installation of this range hood must conform to the Manufactured Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280) or when such standard is not applicable, the Standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI A225 1 /NFPA 501 A, or latest edition, or with local codes.



Keep fan, filters and grease-laden surfaces clean.


Always turn hood ON when cooking at high heat.

Wire sizes must conform to the requirements of the National Electrical Code ANSI/NFPA 70 - latest edition*, and all local codes and ordinances.
Use high range settings on range only when necessary. Heat oil slowly on low to medium setting.

To connect to four-wire power supply, the appliance wiring must be revised. See Electrical requirements.

Don’t leave range unattended when cooking.

Copies of standards listed may be obtained from:

Always use cookware and utensils appropriate for the type and amount of food being prepared.

ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable Codes and Standards, including Fire Rated Construction. The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA),and the American Society of Heating Refrigeration and Air Conditioning Engineers (ASHRAE). and the local code authorities.


SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.

It is the customer’s responsibility:

To contact a qualified electrical installer. To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSVNFPA 70 - latest edition*, and all local codes and ordinances. If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate. Do not ground to a gas pipe. Check with a qualified electrician if you are not sure range hood is properly grounded. Do not have a fuse in the neutral or ground circuit.

NEVER PICK UP A FLAMING PAN -You may be burned.


DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result. Use an extinguisher ONLY if:


You know you have a Class ABC extinguisher, and you already know how to operate it.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

The fire is small and contained in the area where it is started.

Ducted fans must always be vented to the outdoors.

The fire department is being called.

You can fight the fire with your back to an exit.


/ · !


Venting requirements Horizontal wall venting Now start... Vented models only Non-vented models cannot be converted to vent.

With range hood in kitchen.

Slide cardboard or hardboard under range before moving range across floor to prevent damaging floor covering. Cover countertop, cooktop or set-in range with a thick, protective covering to prevent damaging countertop.

Venting system must terminate to the outside. 3-l/4” x 10” through the wail Do not terminate the duct in an attic or other enclosed space.
4 24!l 4 1 W Disconnect and move freestanding range from cabinet opening to provide easier access to upper cabinet and rear wall. Put a thick, protective covering over cooktop, set-in range or countertop to protect from damage or dirt. 2 W If your range hood is a vented-only model, determine which venting method (roof or wall venting) you need to use. Figure 3



Do not use four-inch laundry-type wall caps.

Do not use plastic duct.

Duct needed for installation is not included. Backdraft damper supplied with product must be used. If roof or wall cap has a damper, do not use damper supplied with hood. Use metal duct only. Rigid metal duct is recommended.




Determine which outside venting method you need to use.

The length of the duct and number of elbows should be kept to a minimum to provide efficient performance. The size of the duct should be uniform. Do Not install two elbows together. Use duct tape to seal all joints in the duct system. Duct can terminate either through the roof or wall. Use caulking to seal exterior wall or roof opening around exhaust hood. For the most efficient and quiet operation, it is recommended that the range hood be vented vertically through the roof using 7” round duct.

If your range hood is a non-vented- (recirculating) only model, go to Step 3a, Panel D.



7” min. diameter 7” min. diameter round duct round duct

eibows~--~--i-~i:::i.~

3-l/4” x 10” to round 3-l/4” x 10” to round duct transition duct transition


Figures l-4 show common venting methods and what types of materials are needed.


Use 3-l /4” x lo” or 7” duct with a maximum length of 26 feet for duct system. For best performance, use no more than three 90” elbows. To calculate the length of system you need, add the equivalent feet for each duct piece used in the system. See the following examples.

roof cap , / 7” round vent





3-l 14” x 10”


66” d \‘p7”’ --. .:

2 h. 1 - 90” elbow = 5 ft. 1 8 feet straight = 8 ft. 1 - wall cap = 0 ft.

W Remove knockout from the wirina

- opening (top or rear) to be used. For rectangular venting, remove only the 3-l /4” x lo” rectangular opening knockout for the venting method (roof or wall) you Figure 1 1 Recommended standard fittings have selected.
Length of 3-l/4” x lo” system =13 ft.




Vertical roof venting roof cap / terminal box cover 3-114” x 10” 90” 3-l/4” x 10” fiat 3-l/4” x 10” wail elbow = 5 ft. elbow = 12 ft. cap = 0 ft.



3-l/4” x lo” through the roof

9VeibMF6ft.-q,FP



range hood.

Maximum length = 26 feet

=lO ft. = 0 ft. = 8 ft. Excessive Weight Hazard Use two or more people to move and install range hood. Failure to follow this instruction can result in back or other injury.

3-l/i’x lo” to 7” transition

Length of 7” system = 22.5 ft. Figure 2




keyhole slot front of hood

3-114” x 10” to 7” 90” elbow = 5 ft. 90” elbow = 5 ft. I /


5 45” elbow = 2.5 ft. 7” wail cap = 0 ft. position and center. Mark on the underside of cabinet the location of the four keyhole mounting slots. Set range hood aside on a protected surface.

w W Lift the ranae hood into final


















W Determine and clearly mark a vertical centerline on the woli and cabinet in the area the vent opening will be mode.





cabinet Mark 5-l/8” and 5-7/a” in from bock wall along the centerline on underside of cabinet. Use these points as centers to draw 7-l /8” circles on underside of cabinet.



Use a sober saw to cut the openings for the ductwork. Repeat for the underside of the top of the cabinet. This will create slotted openings.



centerline 7. To wire through fop, mark o line 7-l /2” from the right of the centerline on the underside of the cabinet. Mark the point on this line that is l-3/8” from bock wall. Drill a l-l /4” diameter hole through the cabinet at this point.
















l from wail, not
l from wail, not
cabinet frame I centerline

To wire through rear, mark a line 7-l /2” from the right of the centerline on the wall. Mark the point on this line that is 64-5/a” from the floor (or l-3/8” from underside of cabinet). Drill a l-l /4” diameter hole through wall at this point.
To make a 4” x I 0. -l/2” rectangle on the underside of cabinet top and bottom: a. Mark lines 1” and 5” from the bock wall
To transition from a 3- l/4” x 10” rectangular duct to a 7” round duct and vent through the roof - Start by making a 4” x 1 O-l /2” rectangle on the underside of cabinet bottom: a. Mark lines 1” and 5” from the bock wall


on the centerline of the underside of cabinet.


b. Mark lines 5-l /4” to the right and left of
on the centerline of the underside of cabinet. Now, make a 7-l /8” x 7-5/a” slot on the underside of the cabinet top: b. Mark lines 5-l /4” to the right and left of
the centerline on the underside of cabinet. c. Use sober and keyhole sows to cut a rectangular opening for duct. d. Repeat steps a-c for the underside of the top of the cabinet.



the centerline on the underside of cabinet. c. Use sober and keyhole sows to cut a rectangular opening for duct.

If venting through the wall with 3- l/4” x 10” rectangular duct - To make a 4” x 10-l /2” rectangle in the wall: a. Measure from floor 65-7/a” and 62-3/8” (or l/8” and 3-5/8” down from underside of cabinet) and mark on the centerline on the bock wall. b. Mark lines 5-l /4” to the right and left of





the centerline on the underside of cabinet. c. Use sober and keyhole sows to cut Q rectangular opening for duct.






d. Mark lines 4-l /2” and 5” from the bock

wall on the centerline on the underside of the top of cabinet. e. Draw two 7-l /8” circles using the marks

mode in step d as center points. f. Use sober and keyhole sows to cut a slotted (oval) opening to make installing 7” round duct easier. Panel C




9 n Install duct throuah the vent opening in upper cabinet or wall. Complete venting system according to method needed. See “Venting requirements.” Use caulking to seal exterior wall or roof opening.











Numbers corresoond to steyjs.

have a damper, attach rectangular damper supplied with hood to selected rectangular vent opening. If damper is attached to back of range hood, be sure damper hinge is toward the top. If roof or wall cap does not have a damper and round duct is used, install damper (supplied with hood) in duct to prevent air from flowing back into duct. If roof or wall cap has a damper, Do not use damper blade supplied with range hood.





- 3a H Remove knockout from the wiring opening (rear or top) to be used. The range hood cabinet may have venting knockouts. Do not remove these venting knockouts. The model cannot be vented.



I I from wall,
frame) 11 n Run wirina throuah wall or cabinets according t&-the N%ional Electrical Code and local codes and ordinances. Do not turn on power until installation is complete. Use caulking to seal ceiling or outside wall opening.



7a ~TO wire through top, mark a line 7-l /2” from the riaht of the centerline on the underside ofThe cabinet. Mark the point on this line that is l-3/8” from the back wall. Drill a l-l /4” diameter hole through cabinet at this point.




Check that screw is in narrow neck of slot.



H Start screws in the center of the narrow neck of each of the four keyhole mounting screw slots marked on the cabinet bottom.



H Remove terminal box cover
range hood.


position, feeding electrical wire through wiring opening. Tighten mounting screws to cabinet, making sure mounting screws are in narrow neck of slots. Excessive Weight Hazard Use two or more people to move and install range hood. Failure to follow this instruction can result in back or other injury.
! 7-lfl’ &I-5/8” I 00 floor) i


+ I centerline To wire through rear, mark a line 7-l /2” from the right of the centerline on the wall. Mark the point on this line that is &l-5/8” from the floor (or l-3/8” from underside of cabinet). Drill a l-l /4” diameter hole through wall at this point.






Electrical Shock Hazard Disconnect power before making electrical connections. Connect ground wire to green ground screw in terminal box. Failure to do so can result in death or electrical shock.
8a n Run wirina throuah wall or cabinets according to’ the N$ional Electrical Code and local codes and ordinances. Do not turn on power until installation is complete. Use caulking to seal ceiling or outside wall opening. position and center. Mark on underside of cabinet the location for the four keyhole mounting slots. Set range hood aside on a protected surface. keyhole slot front of hood











H Start screws in the center of the narrow neck of each of the four keyhole mounting screw slots marked on the cabinet bottom. 1 I Connect the white and black wires of the power supply cable to the white and black leads in the range hood with twist-on connectors.




IOa W Lift range hood into final centerline 6a n Determine and clearly mark a

Connect the power supply ground wire to the green ground screw inside the range hood terminal box. Use caulking to seal wire opening. Replace terminal box cover.

position, feeding electric%1 wire through wiring opening. Tighten mounting screws to cabinet, making sure mounting screws are in narrow neck of slots. vertical centerline in the cabinet opening.






If range hood does not operate...


Check that the circuit breaker is not tripped or the house fuse blown.


For best results, turn range hood fan on at beginning of cooking and allow it to run until all smoke and odors are removed from room. To operate fan: Press fan control to turn fan on and off and adjust fan speed. Speed may be increased or decreased anytime during range hood operation. To operate light:

Electrical Shock Hazard Disconnect power before making electrical connections. Connect ground wire to green ground screw in terminal box. Failure to do so can result in death or electrical shock.

If you need assistance...


Call the Whirlpool Consumer Assistance Center telephone number. Dial toll-free from anywhere in the U.S.A. 1-800-253-l 301 and talk with one of our trained consultants. The consultant can instruct you in how to obtain satisfactory operation from your appliance or, if service is necessary, recommend a qualified service company in your area.


Press light control to turn light on or off. Light may be turned to off or on anytime during range hood operation.




If you prefer, write to:

Consumer Assistance Representative Whirlpool Corporation 2000 North M-63 Benton Harbor, Ml 49022-2692



Please include a daytime phone number in your correspondence.
n Connect the white and black wires of the power supply cable to the white and black leads in the range hood with twist-on connectors.


Connect the power supply ground wire to the green ground screw inside the range hood terminal box. Use caulking to seal wire opening. Replace terminal box cover.


If you need service...

For best results, remove and clean often.
Whirlpool has a nationwide network of authorized Whirlpool service companies. Whirlpool service technicians are trained to fulfill the product warranty and provide after-warranty service, anywhere in the United States. To locate the authorized Whirlpool service company in your area, call our Consumer Assistance Center telephone number (see ‘If you need assistance”) or look in your telephone .,.. - directory Yellow Pages under:







. APPLIANCE-HOUSEHOLD- MAJOR, SERVICE & REPAIR - See: Whirlpool Appliances or Authorized Whirlpool Service (Example: XYZ Service Co.)
To remove filter/light lens: Pull firmly on filter tab to remove filter/light lens from range hood. To clean filter/light lens: Place filter/light lens in dishwasher or hot sudsy water to clean. Non-vented (recirculating) only models: Check filter periodically. It should be replaced when it appears saturated or clogged. A new filter assembly, Part No. 883149, is available from your dealer.







To reinstall filter/light lens: Place edge of filter/light lens in opening so that right side is above flange and tab faces downward. Press filter/light lens into position. Fan motor Every three years lubricate each motor bearing with a few drops of oil to help prolong motor life. Clean exterior of motor with a damp cloth and grease-cutting detergent.


If you need FSP@ replacement parts...



FSP is a registered trademark of Whirlpool
Corporation for quality parts. Look for this symbol of quality whenever you need a replacement part for your WHIRLPOOL@ appliance. FSP replacement parts will fit right and work right, because they are made to the same exacting specifications used to build every new WHIRLPOOL appliance.


Exterior surfaces Clean the range hood with a mild detergent and soft cloth. Do Not use abrasive cleansers or steel wool pads.



To locate FSP replacement parts in your
light Do not use bulb larger than 60 watts in light socket. Light bulb is not included.

area, refer to ‘If you need service” or call the Whirlpool Consumer Assistance Center number in ‘If you need assistance.”




Please provide a detailed description of the problem, your appliance’s complete model and serial numbers and the purchase date. This information will help us respond properly to your request.





ground




WHIRLPOOL WILL PAY FOR

FSP@ replacement parts and repair labor to correct defects in materials or workmanship. Service must be provided by an authorized WhirlpoolSM service company.



A. Any labor costs incidental to the replacement of defective parts. B. Consumable parts such as light bulbs and filters, C. Service calls to: 1, Correct the installation of the range hood. 2. Instruct you how to use the range hood. 3. Replace house fuses or correct house wiring. D. Repairs when range hood is used in other than normal, single-family household use. E. Pickup and delivery. This product is designed to be repaired in the home. F. Damage to range hood caused by accident, misuse, fire, flood, act of God or use of products not approved by Whirlpool.






WHIRLPOOL CORPORATION SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states do not allow the exclusion or limitation of incidental or consequential damages so this limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.



Outside the United States, a different warranty may also apply. For details, please contact your franchised Whirlpool distributor or military exchange.


Part No. 626700f883345 Rev. A 0 1998 Whirlpool Corporation @ Registered Trademork/SM Trademark of Whirlpool, U.S. A Benton Harbor, Michigan 49022 Printed in USA


Owners and our team usually reply within a day — and your question helps the next person too.