UL -ES-Elite -WH11 OWNER' S MANU AL MANUAL DEL USU ARIO MR Please write model number here for future reference: / Por fa vor , incluya el número del modelo aquí para futura referencia: Net Weight: 15.
2 UL -ES-Elite -WH11 1. Installation work and electrical wiring must be done by qualified person(s) in accor dance with all applicable codes and standards ( ANSI/NFP A 70-1999), including fire-rated c onstruc tion. 2. Use this unit only in the manner intended b y the manufac turer .
3 UL -ES-Elite -WH11 1. El trabajo de instalación y el cableado eléctrico los deben efectuar personas calificadas cumpliendo con todos los códigos y las normas aplicables (ANSI/NFP A 70-1999), incluyendo las de incendio . 2. Use esta unidad sólo de la manera en que el fabricant e quiere que se haga.
4 UL -ES-Elite -WH11 FEA TURES C ARAC TERÍSTIC AS DOWNROD INST ALLA TION INST ALACIÓN C ON V ARILLA VERTICAL For normal ceilings Para cielorr asos normales V AUL TED CEILING INST ALLA TION INST ALAC.
5 UL -ES-Elite -WH11 Unpack and inspect fan carefully to be certain all contents ar e included. T urn off power at fuse box t o avoid possible electrical shock.
6 UL -ES-Elite -WH11 6 3 Remove the scr ews and star washers from the two ma ting holes (1) on the canopy . Loosen (do not remo ve) the screws in the mating slots (2) on the canop y . Rotate the mounting br acket counter-clockwise and remo ve from the canopy .
7 UL -ES-Elite -WH11 MOUNTING BRA CKET INST ALLA TION INST AL ACIÓN C ON SOPORTE DE MONT A JE Instale el soporte de montaje (1) a la caja eléc trica del techo usando los tornillos y arandelas suministrados con la caja eléctrica.
8 UL -ES-Elite -WH11 FL USH MOUNT OPTION OPCIÓN DE INST ALACIÓN AL RAS 6 Guide motor wires thr ough the base of the canopy as shown and attach canop y directly to top of motor housing with flush moun t screws and lock washers provided . Tighten scr ews securely .
9 UL -ES-Elite -WH11 9 Loosen downr od ball (1) from downr od (2) by removing set scr ew (3). Afloje la esfera de la v arilla vertical (1) de la varilla ver tical (2) quitando el tornillo (3).
10 UL -ES-Elite -WH11 EX TENDED DOWNROD OPTION OPCIÓN C ON VARILLA VERTICAL MÁS LARGA 10 Slide downrod ball (1) off of do wnrod and remov e pin (2). Deslice la esfera de la varilla v er tical (1) hasta separarla de la varilla vertical y quite el pasador (2).
11 UL -ES-Elite -WH11 EX TENDED DOWNROD OPTION OPCIÓN C ON VARILLA VERTICAL MÁS LARGA Feed mot or lead wires through downr od/canopy assembly and insert downrod into downr od yoke . Make sure t o align hole in downrod with the hole in downr od yoke .
12 UL -ES-Elite -WH11 MOUNTING MONT A JE 14 W ith bracket holding fan assembly , make electrical connections using the following step for wiring instructions. Con la pie za de montaje sujetando el conjunto del ven tilador , haga las conexiones eléctricas de acuerdo a las siguientes instruc ciones de cableado.
13 UL -ES-Elite -WH11 WIRING OPTIONS OPCIÓN DE C ABLEADO 16 Follo w diagram above to mak e wiring connections for wall control oper ation. 15 Follo w diagram above to mak e wiring connections for fan pull chain control.
14 UL -ES-Elite -WH11 SECURE T O CEILING ASEGURE EL VENTILADOR AL CIEL ORRASO 17 The canopy has two ma ting slots (1) and two mating holes (2). P osition both slots on canopy directly under and in line with two screws in the mounting brack et (3). Lift the canopy , allowing the two scr ews and star wahers to slide into the ma ting slots.
15 UL -ES-Elite -WH11 2 1 2 1 4 5 3 BLADE INST ALL A TION INST AL ACIÓN DE LAS P ALET AS 19 Check the motor for plastic shipping stabilizer tabs and r emove them if they ar e present. Attach blade assembly to mot or using the noise -dampening motor gaskets (1) and motor screws (2) pr ovided.
16 UL -ES-Elite -WH11 Retire los tornillos (1) de la tapa del juego de luc es (2). Identifique los dos cables en la tapa del alojamiento del int erruptor rotulada “FOR LIGHT” (para las luces).
17 UL -ES-Elite -WH11 22 23 Remove the spot head c over ring by twisting counter clockwise. Install GU10 light bulbs (1), 50 watts maximum. (included) WARNING: 1. Do not allow spot ligh t heads to face each other . 2. All spot lights need to k eep a distance of at least 4 in.
18 UL -ES-Elite -WH11 24 Assemble decorativ e fob and extension chains from hardw are bag to fan pull chains by inserting end of chain into chain coupling.
19 UL -ES-Elite -WH11 OPERA TION AND MAINTENANCE Operation T urn on the power and check operation of fan. The pull chain con trols the fan speeds as follows: 1 pull - high; 2 pulls - medium; 3 pulls - low; 4 pulls - off . Speed settings for warm or cool w eather depend on factors such as room size , ceiling height, number of fans and so on.
20 UL -ES-Elite -WH11 OPERA CIÓN Y MANTENIMIENT O FUNCIONAMIENTO Encienda el ventilador y v erifique su funcionamiento . La cadenilla de tiro con trola las velocidades del v entilador de la siguiente manera: 1 tirón – rápida; 2 tir ones – mediana; 3 tirones – lenta; 4 tir ones – apagado.
21 UL -ES-Elite -WH11 TROUBLESHOOTING GUIDE If you hav e difficulty operating your new ceiling fan, it may be the r esult of incorrect assembly , installation, or wiring. In some cases, these installation err ors may be mistaken for defects. If you e xperience any faults, please check this T rouble Shooting chart.
22 UL -ES-Elite -WH11 GUÍA P ARA SOL UCIONAR PROBLEMAS Si tiene dific ultades para hacer funcionar su nuevo v entilador , podría ser a causa del armado , instalación o cableado incorrectos. en algunos casos , estos error es de instalación podrían ser confundidos con defectos.
23 UL -ES-Elite -WH11.
UL -ES-Elite -WH11 W estinghouse Lighting Corpor ation 12401 McNulty Road Philadelphia, P A 19154 U.S.A. W estinghouse Lighting Corpor ation, a W estinghouse Electric Corporation licensee is a registe.
An important point after buying a device Westinghouse UL-ES-Elite-WH11 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Westinghouse UL-ES-Elite-WH11 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Westinghouse UL-ES-Elite-WH11 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Westinghouse UL-ES-Elite-WH11 you will learn all the available features of the product, as well as information on its operation. The information that you get Westinghouse UL-ES-Elite-WH11 will certainly help you make a decision on the purchase.
If you already are a holder of Westinghouse UL-ES-Elite-WH11, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Westinghouse UL-ES-Elite-WH11.
However, one of the most important roles played by the user manual is to help in solving problems with Westinghouse UL-ES-Elite-WH11. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Westinghouse UL-ES-Elite-WH11 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center