LEPRECHAUN 90 O.S.A WOODBURNING STOVE SAFETY NOTICE Please read this entire manual before you install and use your new room heater. Failure to follow instructions may result in property damage, bodily injury or even death. This appliance is hot while in operation and retains its heat for a long period of time after use.
LEPRECHAUN 90 O.S.A. WOODBURNING STOVE INSTALLATION & OPERATING INSTRUCTIONS GENERAL When installing, operating and maintaining your Leprechaun 90 O.S.A. Stove respect basic stan- dards of fire safety. Read these instructions careful- ly before commencing the installation.
Rear Exit: Fit the heat shield as follows: Screw the four 4” 100mm x 1/4” 6mm tie bolts to the back panel (item 11). Fit the four 1” spacers (item 31) over the tie bolts. Fit the inner heat shield (item 28) without blanking plate onto the four tie bolts.
W ARNING DO NOT OBSTRUCT FREE AIR SUPPL Y T O THE AIR INLET DUCT LOCATED A T THE BACK OF THE STOVE. OUTSIDE AIR CONNECTION This stove may be connected direct to the outside of the house for its combustion air supply . Note: It is recommended to use the shortest possible outside air supply ducts.
7. The chimney system shall comply with the standard for Chimney’s Factory-Built Residential T ype and Building Heating Appliances UL 103. 8. Any openings in a chimney guard if used must not permit the entrance of a 3/4” (19mm) diameter rod.
Chimney, installed in accordance with the manufac- turers instructions or a lined masonry chimney acceptable to the authority having jurisdiction. CHIMNEY CONNECTORS THE CHIMNEY CONNECTOR is a smokepipe used to connect the Leprechaun 90 O.S.A. Stove to the approved chimney described above.
1. Leg 2. Ashtray 3. Base 4. Base Heat Shield 5. Combustion Chamber Base Plate 6. Fire Door 7. Side Panels 8. Inside Fire Door 9. Door Latch 10. T op Side of T op Baffle 1 1. Back Panel 12. Back Baffle 13. Hob 14. Spigot 15. Hotplate 16. Front Frame 17.
THIMBLES Thimbles for chimneys or vent connectors should be of fire clay (ASTM C 315, specifications for Clay Flue Linings), galvanised steel of minimum thick- ness of 24 gauge, or material of equivalent durabili- ty . Thimbles should be installed without damage at the liner .
between the outer wall of chimney section and shall be 12” (305mm). Chimney section concentric with and spaced 1” (25mm) away from connector by means of sheet steel support plates on both ends of chimney section. Opening shall be covered and chimney section supported on both sides with sheet steel supports of min.
has caught fire adjust the primary air settings to suit the heat requirements. 2. The logs will burn slowly towards the rear of the fire chamber and the rate of burning is adjustable at all times by means of the pri- mary air settings. The more air (wider open ing) the faster the burning.
PRIMAR Y AIR SETTINGS MAXIMUM - Pull control lever (item 43) all the way towards the front. LOW (MIN) - Push the control lever (item 43) all the way towards the back. When inspecting a masonry chimney, start at the cleanout door, normally found in the basement, at the base of the chimney, or on the outside.
W ARNING: USE ONL Y CERAMIC GLASS 5mm THICK. ABUSE SUCH AS STRIKING, SLAMMING AND USE OF SUBSTITUTE MA T E R I A L S SHOULD BE A VOIDED. FIRE SAFETY To provide reasonable fire safety, the following should be given serious consideration: 1. The installation of smoke detectors.
An important point after buying a device Waterford Appliances LEPRECHAUN 90 O.S.A (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Waterford Appliances LEPRECHAUN 90 O.S.A yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Waterford Appliances LEPRECHAUN 90 O.S.A - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Waterford Appliances LEPRECHAUN 90 O.S.A you will learn all the available features of the product, as well as information on its operation. The information that you get Waterford Appliances LEPRECHAUN 90 O.S.A will certainly help you make a decision on the purchase.
If you already are a holder of Waterford Appliances LEPRECHAUN 90 O.S.A, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Waterford Appliances LEPRECHAUN 90 O.S.A.
However, one of the most important roles played by the user manual is to help in solving problems with Waterford Appliances LEPRECHAUN 90 O.S.A. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Waterford Appliances LEPRECHAUN 90 O.S.A along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center