It is important to carefully examine the contents with the Chapter Package Contents
after opening the package. If there is anything missing, contact your reseller. Read the
Chapter Physical Description before assembling and operating the device and
peripherals. Understanding the physical description can prevent damage caused by
abnormal usage and reduce most problems during installation.
Basically Network Camera is a network device and should be easy to use for those who
already have basic network knowledge. If there is a system error and it does not recover
easily due to erroneous configuration, read the System recovery section in Appendix
Troubleshooting to restore factory default settings and perform installation again.
Network Camera has been designed for various environments and can be used to build
various applications for general security or demonstration purposes. For standard
applications, find the appropriate section in the Chapter How to Use for your application
and follow the steps to setup the system. To make best use of Network Camera, read
Chapter Advanced Functions to get creative ideas and review Chapter System
Configuration for detailed explanations of system configurations. To those professional
developers, the Appendix URL Commands of Network Camera will be a very helpful
reference to develop a Web-based application.
Surveillance devices may be prohibited by law in your country. Though Network Camera
is not only a high performance surveillance system but also a networked video server,
ensure that the operations of such devices are legal before installing this unit for
surveillance.
Those paragraphs preceding with
must be fully understood and cautioned.
Ignoring the warnings may result in serious hazards.





If any of the following items are missing, please contact your reseller.




CS Ring and wrench



Network Camera is a high-performance networking video transmitter. With powerful
VLIW DSP core and fully optimized algorithm, it can compress and transmit the high
quality real-time video through standard TCP/IP inter-network. In addition to meet the
basic needs of video feed, many advanced features are added to help building
applications of surveillance or web attraction. The state-of-art design well compromises
among stable, robust, simple-to-use and flexibility.
☆ Real-time motion-JPEG compression
Video input can be efficiently compressed into packets of JPEG images without delay.
Optimal compression engine makes the equivalently excellent image with much smaller
size. There is no more sacrifice in remote monitoring and storage. Five levels of
compression ratio and three sizes of image resolutions are easy to meet your
requirement.
☆ Robust system operation
Industrial real-time operating system prevents from malicious hackers and virus that
threat Windows or Linux systems. The on-board watchdog eternally monitors the system
operations for dead-proof.
☆ Easy Web access via standard browser
You don’t have to install any software to access Network Camera. The embedded Web
server makes users can access Network Camera anywhere over Internet with any
popular Web browser. As long as you are connected to network, you can cast your eyes
on your precious property.
☆ Password protection of system access
Password level protection is provided by the system to prevent from malicious intruders
from network. Once the password of administrator is entered, any user will need
password authentication to access Network Camera. Each user can have individual
access right to view video or control external devices.
☆ Built-in motion detection
No more external sensors are required. The video channel can be setup to detect any
motion with customized settings. By tuning the object size and sensitivity, it is more
reliable to fit into your environment. With this built-in facility, you can easily setup a

security system in your home or office.
☆ Weekly schedule for automatic surveillance
The user-defined time period will repeat weekly to check any security settings and accordingly sending notification or drive external devices. It is easy to install in SOHO, retail shop and home as a security system. ☆ Flexible I/O control for external devices
There is one opto-isolated sensor input and one relay output to control external devices.
System integrators can easily replace the current analog systems to build an advanced
security system.
☆ Remote system upgrade
To achieve the promise we made to support our valuable customers in life-time, the most
up-to-date firmware is always put on our web site to add new functions or solve known
bugs. A free upgrade wizard is included to facilitate the job.
☆ Developer’s technical support
The high-performance Network Camera can be integrated into many applications under
perfect control of budget. The complete programming interface and standard JPEG
format can ease and speed developers’ task. More creative ideas can be found on our
Web site.

Front Panel

The dual color LED indicates system and network status including power-on-self-test and
system activity. Refer to the Appendix for details.
The ring of the lens can be rotated to fine tune the focus. The video output at the rear
panel can be used to monitor.
If another special lens is needed to replace the bundled one, the image may be out of
focus for new lens and not able to fine tune by the manual focus ring. Use the included
wrench to loose the screw to adjust the internal ring to get the best focus. Then tighten
the internal ring to fix the focus.
Manual focus ring · Status LED · Internal ring screw


A 75Ohms-resistance video connector can be connected to a TV for monitoring the video
from the front CCD sensor.
Connect to an Ethernet network with a UTP category 5 cable of length shorter than 100
meters according to the standard.
There is a button hidden in the pinhole beside the Ethernet socket. It is used to reset the
system or restore the factory default settings.
1 Å DI- INPUT (Max. 50mA, 12VDC)
3 Å SW_COMMON OUTPUT (short with NC at initial state)
4 Å SW_NOPEN OUTPUT (Max. 1A, 24VDC or 0.5A, 125VAC)

Network Camera provides a general I/O terminal block with one digital input and one
relay switch for device control. Pin 1 and pin 2 can be connected to an external sensor
and the state of voltage will be monitored from the initial state 'LOW'. The relay switch
of pin 3 and pin 4 can be used to turn on or off the external device.
Connect the power jack of the included power adapter. Connecting the power adapter
should be the last operation while physically installing Network Camera.

To easily fit into various environments, Network Camera automatically detects the
attached interfaces and configures itself to the best condition. The high performance
built-in CCD and lens always give users delicate image quality.
In the following content, "user" refers to those who can access Network Camera and
"administrator" means the supervisor who has the root password to configure Network
Camera in addition to general access. Administrators should carefully read this manual,
especially during installation.

Before installing multiple Network Cameras at the well-chosen locations, the
administrator should memorize the serial numbers on the packages respectively for
future use.

Connect the supplied cables from Network Camera to related devices according to the
above diagram. Note that the power adaptor must be kept unplugged until other cables
are firmly connected.
Make sure all cables are correctly and firmly connected before turning on Network
Camera. Turn on cameras, sensors, alarm devices, and then attach the power adaptor of
Network Camera to the electric power socket. After the POST (power-on self test) is
complete and the result is successful, Network Camera is ready for software
configuration as described in this manual. At this stage, network speed and video
modulation type are automatically detected. Refer to the configuration section for
further information.
Connect the power jack of the power adapter to Network Camera prior to plugging
the utility end into the utility power socket. It will reduce accidental electric surge shock.
Cable connection

In order to configure Network Camera’s remotely, administrators should keep the serial
numbers of the new Network Camera’s for identification and initial passwords. After
successfully mounting Network Camera’s in the proper position, run the Installer
program on the PC in the same network to locate the newly mounted Network Camera’s.
Network Camera’s also support manual setup procedures to non-Windows based
environments. The manual procedure is described next.




After the POST is done, Network Camera will try to configure itself by detecting the
network environment. If there is DHCP service over the network, the Installer program
will catch the given information, then display the serial number and given IP address for
each Network Camera as the figure above. To install the IP address, follow the steps.
○ 1 Click on the entry with the serial number you want to install. If the "Assigned" field of
the entry is labeled "Yes", that means the Network Camera has already been installed.
○ 2 Type the desired IP address if it is other than the IP address given by the DHCP server.
○ 3 Check the box to fix the IP address of the Network Camera. Otherwise the Network
Camera will lose the network address at next system boot and you have to run this
installer again.
to progress the installation.
○ 5 After successful notification, administrators may keep the address information and
○ 4 Click

to access the Network Camera in the default browser. If the IP address is taken by another network device in the network, the Installer
program will pop out another message window to warn that the assigned IP conflicts. In
this case, administrators should ask the network supervisor for a vacant IP address.
While “Use this IP whenever system boots",

is checked, a dialog window may pop out to ask
for “Server FTP Port” and “Root Password”
because they are already changed by
administrators to other than default settings. If
the original settings are lost, restore default
settings and run software installation again.
Once the installation is complete, administrators should follow the First access to
Network Camera section for necessary checks and configurations.
click directly on

Manual way with existing programs
For those environments such as MAC, Linux, Unix or other operating systems, whose
installer is not yet available, some common network tools including ARP and PING can be
used to install Network Camera. Before proceeding further, make sure ARP and PING
programs exist.
First, type arp –s “assigned IP address” “Ethernet address” to add an entity in the
system’s name table. The Ethernet address is identical to the serial number of Network
Camera and should be typed in the appropriate format like “uu-vv-ww-xx-yy-zz” or
“uu:vv:ww:xx:yy:zz”, which depends on the operating system.
Once the name entity is added, type ping "assigned IP address” to invite the new
Network Camera. If it replies, that means Network Camera has accepted the assigned IP
address and is ready for access. The first several ping requests may fail during the
self-configuration period of Network Camera. Since the accurate grammar of ARP and
PING depends on the operating system, refer to its related help manual.
Example of DOS prompt in Windows 2000


Starting the Web browser to connect to the assigned IP address of Network Camera,
users will be asked for user name and password by an authentication message window.
A root password, identical to the Network Camera's serial number, is needed for the
initial access to a newly installed Network Camera. The administrator must change the
root password immediately after the initial installation to ensure security. The new root
password should be well memorized since there is no way to retrieve or recover it. After
changing the password, the browser will display an authentication window again to ask
for the new password. If the root password is deleted as blank, the authentication
mechanism will be disabled.
For complete protection from illegal usage, Network Camera provides three privileges
and always needs user name and password before access. The lowest level is DEMO
mode whose services are subject to administrator's permission. The standard level is the
USER mode that consists of twenty user profiles. Each user is able to access Network
Camera under the given privilege, except for system configuration. The twenty user
profiles are also maintained by the administrator. The highest level is ROOT mode that
only opens to administrators for initial setup, system configuration, user administration
and software upgrade. The user name of the administrator is internally assigned to
“root”.
Complete the network settings
Although Network Camera already can be accessed after software installation in local
area network, administrators should complete the network settings in the configuration
page. The complete network configurations including subnet mask as well as the IP
address of default gateway and DNS are provided by your network administrator or
Internet service provider. Once the wrong network settings make Network Camera fail to
work, refer to Appendix A to restore factory default settings.
By default Network Camera will need administrator's installation every time it reboots. If
the network settings are sure to work all the time, disable the install option in network
configuration Web page or Installer program.
Details about configurations are described in the relative category of the Chapter
Definitions of Configuration.
Manage user privilege

Open your familiar web browser and connect to Network Camera just like any general
web site and the video will present on demand. Make sure the web address of the target
Network Camera is accurate.
After opening the Web browser and typing in the URL of Network Camera, a dialogue
window will pop out to request a username and password. For administrator’s initial
usage of Network Camera, enter the username as “root” and the password as the serial
number in capital letters. The serial number can be found on the labels under the body
of Network Camera and the top side of the carton. The primary users will be allowed to
enter as soon as the administrator finishes adding user profiles. Upon successful
authentication, the main page will be displayed.
For demonstration purpose, enter the Security Web page of configuration to activate the
demo account and choose permitted services. Once the demo account is setup, any one
may watch the video by using “demo” as user name while ignoring the password.
Different from primary users, the demo account has certain limitations that are
determined by administrators.
In the figure, the foreground is the

login window and the background
shows the message when
authentication fails. The user may
check the option to save the
password for future convenience.

If it is initial access to Network Camera via the Web browser supporting server push, the
motioned pictures will display directly. If the Web browser is Internet Explorer in
Windows, users will be asked to install a new plug-in that is provided by Network Camera.
This plug-in has been registered for certificate and is used to display motioned pictures
in the Internet Explorer. Users may click on
to install the plug-in. If the web
browser does not allow the user to install, check the security option to lower security
levels or contact network supervisors.


Basic functions are displayed in main entrance page of Network Camera. The first figure
below is graphic mode that has better visual effect and the second one is text mode that
will shorten download time. The main page may look different depending on the PT
scanner or the privilege of the user.



Text mode is default
if any image button is
not available.
It allows users to adjust the video quality for speed or smoothness. The performance is
also subject to the network bandwidth and the number of users. Five options are
available to be chosen from “Medium” to “Excellent”. “Medium” quality means the
picture has the quickest refresh rate but the worst image quality and “Excellent” quality
means the picture has the slowest refresh rate but the best image quality.
It allows users to adjust the image size with consideration of bandwidth and image
resolution. Five options are available including “Half”, “Half×2”, “Standard”,
Text mode · Network Camera

“Standard×2” and “Double”. “Half×2” consumes the same bandwidth as “Half” but
has the same size with “Standard”. Of course the visual effect is worse than “Standard”.
“Standard×2” compared to “Double” is similar to the case. “Half×2” is especially suits
in the low bandwidth environment like a dial-up network. To fit into the small image area,
timestamp will be skipped in “Half” and “Half×2” modes.
There is a button or text link in the left side of the system configuration that only appears
in administrators’ main page.
There may be two remote control buttons for the each digital output on the main page.
If there are external devices attached to the digital output, administrators or permitted
users can click on
to short “Common” and “Normal Open” pins of the digital output
to short “Common” and “Normal Close” pins of the digital output. To
know more about the digital output for external devices, refer to the rear panel
introduction of the Chapter Physical Description.
or click on

Introduction
The system configuration can be easily done remotely on Internet Explorer through the
Web interface. There are two wizards in addition to classified categories of system
configurations. They can give friendly instructions and facilitate the setup job.
Alternately administrators may type directly the URL of system configuration,
“http://<IP address of Network Camera>/setup/config.html”, to directly enter the
configuration page. If administrators also want to set certain options through the URL,
read the relative section in the Chapter Advanced Usage for reference. Network Camera
also supports FTP to modify the system configuration file, CONFIG.INI, for technical
usage. The details are described in the Chapter Advanced Usage.
Since it is a networking video server, administrators should run “Setup wizard” or well
configure “Security”, “Network” and “Video” at least. To utilize the built-in features of
security and web attraction, run “Application wizard” or configure “Application” and
“Demo”. Besides these features, administrators can adjust the system date and time in
“System”, or have different homepage layout by configuring “Homepage layout”.
Network Camera also provides some system maintenance like “View log file”, “View
parameters” and “Factory default”.

The setup wizard will guide administrator to enter necessary information including
system name, current date and time, administrator’s password, video configuration and
captions, and network settings. Administrators can exit the procedures anytime to
reserve the current configuration. Finally the setup wizard will ask for reboot to validate
the changes and administrators can decide to reboot later.
There are two main applications including surveillance system and web attraction by
means of Network Camera. The former one will utilize the built-in motion detection and
external sensors to integrate with the existing e-mail or FTP server or external alarms to
construct a security system. It also possesses the weekly schedule for timed monitoring.
The later one will customize the main page to your personal style and setup accounts for
your possible visitors. The application is perfectly constructed and performed on several
clicks by your fingertip. Administrators can additionally configure the application
parameters in the Application page of configuration for more advanced usage after using
Application wizard.

The “host name” is used for the homepage title of main page and displays as the title
over the video window on the main page. The maximum string length is 40 characters or
20 characters in double-byte-character-systems like Chinese or Japanese.
Adjust date and time
There are three ways to adjust system date and time. The easiest is to make Network
Camera "Sync with computer time". The second “Manual” is to set the date and time
manually by entering new values. Notice the format in the related field while typing. The
third “Automatic” is to make Network Camera automatically synchronize with
timeservers over the Internet every month. It may fail if the assigned NTP server
cannot be reached or Network Camera is within a local network. Leaving the NTP server
blank will let Network Camera connect to default timeservers. Domain name or IP
address format is acceptable as long as DNS server is available. Do not forget setting the
"Time zone" offset for local settings. Refer to the Appendix E for the time zone of your
region. It only affects the hour in NTP method. “Update interval” can make the server
to synchronize the system time to NTP server every hour, every day, every week or every
month.
Once the settings are changed, click on
to validate changes.

To change the administrator’s password, type the new password in both text boxes
identically. What is typed will be displayed as asterisks for security purposes. The
maximum password is 16 characters. After pressing
, the web browser will ask
administrators for the new password for access.
To add a new user, type the new user's name and password, check respective privilege,
to insert the entry. There are a total of twenty user accounts. Each
user can have independent access right of the video channel and external I/O access.
If the permitted rights of some user has to be changed, pull down the user list to find the
user name and press
. A new window will pop out for administrators to change
password and choose different privilege.
To delete a user, pull down the user list to find the user name to be deleted and press
. A message window will pop up for confirmation.
To setup Network Camera for demonstration to the public, administrators need to choose
the service(s) to be permitted. After checking “view” in Security page, users may use
“demo” as general user name and password is not required. Administrator also can
assign “ I/O access” option to demo account. To separate the demo account from primary
users can prevent from interfering with the normal operations.
Enable snapshot mode for more users
The maximum users that can view Network Camera at the same time are twenty.
Administrators can check “Allow more guests with snapshot mode” to enable the
snapshot mode for more users. Then the users over twenty will have the main page with
snapshot mode instead of normal motion picture. It is practical for web attraction. In
such case, configure the “Snapshot interval” to achieve better performance. The
bigger interval between snapshots, the more users can have snapshot mode work.

To eliminate incautious mistakes during installation, Network Camera will stay in
installation mode whenever it starts unless "Reset network at next boot" is disabled.
This option can also be disabled using the Installer program. Once the option is disabled,
Network Camera will skip installation at the next boot and the Installer program will not
find the installed units. That implies that Network Camera cannot be accessed if no one
remembers the IP address, except for restoring factory default settings. However, with
this option disabled Network Camera can automatically operate normally after restarting
in case of losing power.
Administrators may need to modify the network settings to fit into existing networks.
The subnet mask in some broadband service may differ from the default value
255.255.255.0 and service providers may assign more specific network settings.
Administrators should change the configuration to what given by the service provider.
The configuration may include "IP address", "Subnet mask", "Default router",
"Primary DNS server" and "Secondary DNS server". After changing network settings,
be sure to leave "Reset network at next boot" blank to skip next installation when the
system restarts. Otherwise those network settings will be erased at the next start.
Each Network Camera can be limited in bandwidth utilization by administrators
according to its priority and importance of location. "Bandwidth limit" is most useful to
balance network utilization when multiple Network Camera’s are installed in the same
network. It is more effective than changing image quality only and achieves better
performance with adequate image size and quality.
Changing port number of servers
For security or network integration, administrators also can hide the server from the
general HTTP port by changing "HTTP port" to other than default 80. “Local FTP
server port” can also be changed to other than default 21. Administrators should have
enough network knowledge to change the default port.
Network Camera not only plays the role of server, it will also actively connect to servers
outside to send out messages or snapshots. When Network Camera starts, it will send
out a system log via e-mail as long as the settings are correct rather than upload it via
Basic network settings · Bandwidth utilization limit · E-mail settings

FTP. Even in modem application, Network Camera will send out a connection log
whenever it dials out to an ISP or dialup server outside. If the administrator has setup
some applications in either event mode or sequential mode, Network Camera will send
out snapshots once conditions are met. To activate e-mail function, enter correct
settings of "SMTP (mail) server" and "Recipient email address". "Secondary SMTP
(mail) server" and "Secondary email address" are provided for backup connection
when the primary one fails. “Return email address” is whom the mail will return when
the SMTP server rejects upon any failure. Some ISP may reject the mail if the address is
invalid.
To send the log files described in the above paragraph via FTP, the SMTP server should be
erased. Administrators must enter correct "Primary FTP Server", "Primary FTP user
name" and "Primary FTP password". "Primary FTP remote folder" is the relative
sub-folder in the remote FTP server. If the port of the remote FTP server is changed other
than 21, set the real port to “Primary FTP server port”. If the local network is
protected by a firewall to prevent from initiating FTP connection from the remote FTP
server, you may be able to connect to the FTP server but unable to put any file due to
data channel connection failure. Check “Primary FTP passive mode” for passive
transfer solution. Another set of "Secondary" server settings is also provided for backup
connection.
In either e-mail or FTP, the primary server information should be entered first. If the
primary server is not set, the related FTP or email will be cancelled. Note that it may take
time to connect to the secondary server after the first one fails and it may affect some
applications when conditions happen too often.
After everything is set, click on
. A warning message will pop out for confirmation.
, Network Camera will automatically restart. If "Reset network
at next boot" is kept checked, perform software installation again. Otherwise Network
Camera will boot up according to the new configuration automatically.
Any change made to this page will make the system restart to validate. Make sure
every field is correctly typed before clicking on
. If Network Camera fails to response
due to erratic settings, perform the restore procedures and run software installation.
FTP settings · After clicking on

Administrators should notice that the basic network settings including IP address,
subnet mask, default router and DNS servers will be cleared when the network interface
is switched to the other between Ethernet and modem.
"Time stamp" and "Text on image" will be enclosed in image for reference. The
timestamp is captured from date and time of Network Camera that is maintained by an
on-board real-time clock. "Color" setting is independent of the connected camera and
“B/W” option can speed up the encoder a little. “Default size” option here will be the
default size of video window when users first connect to Network Camera. “Default
quality” option here will be the default quality when users first connect to Network
Camera. To adjust image settings for best visual quality, press
and a motion picture window will pop up for your reference. There are four fields including
"Brightness", "Contrast", "Hue" and "Saturation" for video compensation. Each field
has eleven levels ranged from -5 to +5. While adjusting, administrators can click on
to check prior to
the setting in memory. If the adjustment is not good,
administrators can click on
to restore the original settings without change. After
configuration done, click on
to close this window. If parameters are changed
without saving, they will be used until the next system startup.
The channel can have its own settings of motion detection independently. The settings
including “Object size” and “Sensitivity” allow administrators fine tune to fit into the
environment. The “Object size” decides the space ratio of motioned objects over the
monitored screen. The “Sensitivity” sets the measurable difference between two
sequential images that would indicate motion. The larger object size and lower
sensitivity will make Network Camera ignore small variations in images. While the
motion amplitude of some object in the monitored screen is over the settings, a white M
in red background will indicate at the upper-right corner of the window.
Motion detection is provided as reference because it is very environment-dependent.
Especially working by the very sensitive settings, some triggered events may be
considered as false alarms though there is tiny difference happening indeed. It can be
affected by florescent light flashing, shadow shifting, and so on.
Configure motion detection

Administrators can use combinations of options on the application page to perform many
useful security applications. Network Camera provides two application modes; one is
performed according to the settings on the web page, the other is performed according
to the external command script. Though most settings will automatically be done by the
Application Wizard, administrators still can adjust the settings from this page.
A useful weekly schedule is provided for daily security application. Administrators can
select weekdays from Monday to Friday with the daily schedule from 9:00 am to 6:00 pm
that no one is at home to perform any event checking. If the security system needs to be
installed in office that no one is there during the nights or weekend, administrators just
set the time period as above, then check “All the time except for the above
schedule” for opposite operations.
Administrators can write a script named SCRIPT.TXT to perfectly match the additional
software according to the Command Script for Complex Applications section in the
Chapter Advanced Functions. After uploading this script to Network Camera via FTP,
check the option “Enable the external script file to exclude the following settings”.
Otherwise Network Camera will operate according to the settings below.
Network Camera provides general options for two basic applications, event operation
for security and sequential operation for web attraction. In event operation,
administrators have to setup some conditions to check and some actions to happen
consequently. The conditions include motion detection and the status of digital input.
While checking “Detect motion” box, administrators should click “Motion Detection”
button on Video page or click “Motion Detection” link in Application page to configure
the appropriate parameters. In the newly opened window, percentage of object size
over whole window and sensitivity can be fine tuned to fit into the environment. If any
motion is over the settings, an ‘M’ will appear on the upper-right corner of image for
indication. The ‘M’ will appear in the image to indicate some motion is detected as long
as “Show alert in image” is checked. If there are any sensors attached to the digital
input, administrators can set the state to fire alarm. There are four states of “Input is
High”, “Input is Low”, “Input is Rising” and “Input is Falling”. The edge trigger like
“Rising” or “Falling” is generally used to detect the emerging signal from the external
sensor. Once any event happens, administrators can select “Delay second(s) after
Weekly schedule · External command script · Event operation

event” option to drive some device attached to the digital output several seconds after
the event happens and/or send snapshots that are taken right at the moment. . If
administrators want to receive some snapshots to check the event, please check the
“Upload snapshot while input condition match” box to get snapshots when
inputting condition is matched the setting or check the “Upload snapshots while motion detected” box to get snapshot when motion has been detected. Network
Camera will take three snapshots of pre-event, the moment of event, and post-event for
video channel. Three snapshots of the channel can also be downloaded via FTP or HTTP
URL. Refer to the Download Event-triggered Snapshots section for details.
With this feature, Network Camera can upload snapshots periodically to external server
as a live video source. The interval can be set from tenth second to several hours. The
external server must be setup correctly in the Network configuration page.
Either event mode or sequential mode can select one method between email and FTP.
The companied external server must be setup correctly in advance. If email is chosen,
the snapshots of the video channel will be attached in the emails. If FTP is chosen,
administrators can choose to add date and time in the file name of snapshots. If the
snapshots are used as the live video source, the date and time suffix can be eliminated
to update the same source file.
The option “Show alert in image” may be set when running application wizard or
configuring motion detection. Administrators should manually uncheck it if no indication
of motion detection is needed in the image.
Sequential operation · Sending method

There are two homepage display modes. One is "Image mode" that uses graphics for
links; the other is "Text mode" that mostly uses text for links.
Administrators may easily give Network Camera a different presence of homepage. The
"logo graph" for the system logo at the upper-left corner can be hidden; or the default
image from the system memory can be used; or an external resource can be used by
assigning a URL. The "Background graph" is similar. Default images of the system can
be customized but limited by memory size. Images from external resources can be
larger and more beautiful but will need more time to load. If the background is skipped,
the background color will fill the browser window. Administrators also can give the
system logo a "Logo link" to connect to another web site while clicked. The "Font color"
and "Background color" can be chosen from sixteen colors as you like. See the
Customize graphics in homepage section in the Chapter Advanced Functions for how to
replace the default images of log, background and buttons of video switch.
If any necessary image is lost while homepage layout is image mode, Network
Camera will switch to text mode automatically.

There is some useful information in the system log including current system
configuration and activity history with timestamp for tracking.
The whole system parameters will be categorized listed for administrators to check. The
content is the same as CONFIG.INI.
It is used to restore the factory default settings. This means any changes made before
will be lost and the system will be reset to the initial status as shipping out of the factory.
After confirmation, the system will restart and require the software installation to setup
the network.

Capture Up-to-date Still Images
Administrator and users can use the specific URL to capture the current still image.
http://<IP of Network Camera>/cgi-bin/video1.jpg[?=]

Administrator and users can log-in the FTP daemon of Network Camera to download the
refreshed JPEG image named video.jpg. The user name and password are as same as
what in web access. The zero file size in file directory means it is captured by request.

In additional to the URL, some scripts should be added to download a plug-in for motion
pictures. The following example simply displays title text and a real-time video window
in Internet Explorer or Netscape. The user name and password should be configured in
advance. Those who are familiar with HTML can easily add more components or rewrite
a more vivid and useful homepage.
Network Camera Sample Page
Network Camera Sample Page
if ((navigator.appName == "Microsoft Internet Explorer")&&(navigator.platform != "MacPPC"))
document.write("
document.write("CLASSID=\"CLSID:EAA105FE-7BBD-4196-8B96-D46743894195\" ");
document.write("CODEBASE=\"http://root<root_spassword>@/plugin/mjpegcontro
l.cab#version=2,0,0,0\">");
document.write("");
document.write("
VALUE=\"http://root<root’s_password>@/cgi-bin/video.jpg");
document.write("?cam=1&quality=3&size=2\">");
document.write("");
document.write("
document.write("src=\"http://root<root_password>@/cgi-bin/video.jpg?ca

There are three video image files for the video channel of three stages: pre-alarm, the
moment when triggered and post-alarm. Only the snapshots captured by the last event
are preserved. Administrator and users can use FTP or URL to get the saved snapshots.
They can also be browsed from the application page in system configuration.
/cgi-bin/snapshot.jpg?file=
snapshot before event Pre1
snapshot upon event Trg1
snapshot after event Pos1
File name Pre-alarm Upon alarm Post-alarm
Video vpre.jpg vtrg.jpg vpos.jpg
Video channel · Video · Snapshot stage

In sequential mode, Network Camera will send out snapshots according to interval and
period settings. If snapshot files are intended for quick updates, it is better to skip date
and time suffix. The file name will then be video.jpg. If the snapshots are used for
occasional monitoring, suffix with date and time can help administrators classify them
easily.
Comparing to the FTP method, email will induce more delay. But the email can notify
users for prompt action.

While in text mode, there is a small icon named BTN_TEXT.GIF preceding with each link
that can be changed by administrators. While in image mode, the default method will use
the image stored in Flash memory. The followings are the referenced file name and size
limitation of each stored images. Administrators may customize preferred image under
the size limit and put to the specific name via FTP. Administrators can download the
original images before upload for backup.
Object File name Maximal size
Logo logo.gif Logo and background share 8000
Background back.gif Logo and background share 8000
Link icon btn_text.gif 2000 bytes
Configuration btn_conf.gif 5000 bytes
Usage via FTP is illustrated as below.



bytes · bytes

Besides the application wizard, Network Camera provides a more professional command
script for advanced applications. The command script will be executed exclusively with
the settings in Application page of system configuration except for the weekly schedule.
To build the advanced application, follow the steps below.
format. The script size cannot exceed 500 bytes.
schedule. If it is supposed to run any time, keep the original settings but check the
option “All the time except for the above schedule”.
activate the command script.
[“Digital Input Number””Digital Input State”]
[“Channel Number””Video Input State”]
“*”: (AND)
[(“Delay Time”)“Digital Output Number””Digital Output State”]
[“V”“Channel Number”“P”“Preset Location Number”]
[“W”{“IP”:“Port”}{“Message”}]
Item between brackets means optional but at least one item should exist.

“M”: motion detection event.
loss), X (as long as signal loss)
The filename format is,
%a image characterization (pre, trg, pos)

M1=1C; When any motion is detected, “Normal Close” of relay output will
short with “Common”.
1\=(5)1O; When DI transients from high to low, “Normal Open” of relay
output will short with COMMON in 5 seconds.
If there is no video signal, a message “no signal!” will be sent to
:6000}{no
port 6000 of 192.168.0.1 once.
1H=V1P15; When sensor input 2 is high, drive the camera mapped to video
1 to go to preset location 16.
If any motion is detected, upload snapshots. If an event
triggered at 19:05:30 2002/10/15, the snapshot files will be
The script file is limited to maximum 500 characters. The actual performance will
depend on the complexity of the command script. Administrators should reduce the
redundant check as possible. Overload conditional check and heavy actions may retard
the system operation.

/cgi-bin/getdi.cgi
Network Camera will return the status of digital input.
/cgi-bin/setdo.cgi?do1=
: C, O denoting Normal Close or Normal Open respectively.

Besides viewing the system log from the web page, administrators can download the
system log file, SYSTEM.LOG, via FTP. To log into the FTP daemon, enter “root” as the
user name and the same administrator’s password used in Web access.
/cgi-bin/reset.cgi
Restart Network Camera without warning.
/cgi-bin/restore.cgi
Network Camera will automatically restart after restoring factory default configurations.

Administrators can use FTP to configure Network Camera much quicker than Web page
especially for multiple targets. To configure system via FTP, first download the parameter
file, CONFIG.INI, to customize each field according to the environment and then upload
back to validate the new settings. To log into the FTP daemon, enter “root” as the user
name and the same password used when connecting to the Web server. The serial
number of Network Camera is the password for the initial access.
The file is composed of eight categories: [SYSTEM], [LAYOUT], [NETWORK], [VIDEO],
[ALERT], and [DEMO]. The category name in brackets should be in upper case. The item
name in angle braces should be in lower case. Some items related to disable/enable
should use the keywords “YES”/“NO”. The number zero entry in and
password> is for administrators, i.e. “root”. Basically Network Camera will restart
automatically as soon as the file is accepted. If administrators want to cancel the reboot
procedure, set the first item, to NO. It will take effect once only and
always show YES in the download file.
A sample CONFIG.INI is attached below. The italic text following each line describes the
characteristic of the field and the bold italic characters are the options of the field.
Network Camera Initial Configuration File
[SYSTEM] YES or NO Network Camera string of maximum 40 characters 0002D1040011 read-only IP21x2-VVTK-0101c read-only 2004/06/08 read-only 12:34:56 read-only 0 from 12 to -12 (0)root read-only (1) string of maximum 16 characters (2) the followings are as same as the above (3) (4) (5) (6)

(7) (8) (9) (10) (11) (12) (13) (14) (15) (16) (17) (18) (19) (20) (0)0002D1040011 string of maximum 16 characters (1) the followings are as same as the above (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (16) (17) (18) (19) (20) NO or YES to enable snapshot mode 0 seconds of snapshot interval [LAYOUT] 1 image mode or 0 for text mode 0-black, 1-white, 2-green, 3-maroon, 4- 1 olive, 5-navy, 6-purple, 7-gray, 8-yellow, 9-lime, 10-aqua, 11-fuchsia, 12-silver, 0 13-red, 14-blue, 15-teal, 1 default image, or 0 for blank, or 2 from URL 1 default image, or 0 for blank, or 2 from URL http:// URL of logo type 2, maximum 80 characters http:// URL of logo type 2, maximum 80 characters http:// reference link of logo, max. 80 characters

string of maximum 8 characters [NETWORK] YES reset IP whenever system boots or NO NO obsolete 00-02-D1-04-00-11 read-only 192.168.0.207 standard IP format 255.255.255.0 standard IP format 0.0.0.0 standard IP format 0.0.0.0 standard IP format 0.0.0.0 standard IP format NO or YES IP address or domain name IP address or domain name string of maximum 80 characters Network Camera string of maximum 80 characters IP address or domain name string of maximum 80 characters 21 or 1024 ~ 65535 IP address or domain name 21 or 1024 ~ 65535 string of maximum 16 characters string of maximum 16 characters string of maximum 40 characters NO or YES IP address or domain name 21 or 1024 ~ 65535 string of maximum 16 characters string of maximum 16 characters

string of maximum 40 characters NO or YES 80 or 1024 ~ 65535
0 or 64000, 128000, 256000, 512000, 768000, 1000000, 1500000, 2000000 [VIDEO] NO or YES YES or NO 4 8,6,4,3,2 representing Medium, Standard,
1 0,1,2,3,4, representing Double, Standard, Half , Standard x2, Half X2 0 among 5 and -5 0 among 5 and -5 0 among 5 and -5 0 among 5 and -5 [ALERT] NO or YES to activate external script NO or YES NO or YES NO or YES 0 disabled, 1 for Sequential, 10 for motion detection event, 12 for DI event NO or YES 0 FTP, 1 for email YES or NO 10 1~99

90 1~99 5 1 00:00:00 24 hours format 00:00:00 24 hours format [DEMO] NO or YES NO or YES

Network Camera has a Telnet daemon for only administrators to access some seldom
used functions. Using any general terminal program to connect to Network Camera will
prompt the user for a password. Username is not requested here since only
administrators can access the Telnet daemon. The password is as same as that used in
web access. After logging in, type "help" for the command list. If "debug" or "dinote" is
not executed, Telnet will disconnect automatically after being idle for 1 minute. System core debugging
General activities are recorded into SYSTEM.LOG continuously, but information about
abnormal status is not. To look deep into the core debugging information, administrators
may type the “debug” command. This will cause Network Camera to start dumping the
detailed debugging information while the system is running. This is useful to examine if
any error has occurred when the system operates abnormally. The stored information
will be cleared automatically after the dump. Network Camera will continue to dump new
messages unless the connection is broken. If Telnet is not connected, any messages will
Typing "dinote" will make Network Camera send the current status of digital input. After
that Network Camera will continuously monitor DI status and send messages only when
the state has changed. For example, after typing "dinote" the terminal will display
and after DI1 changes to H, terminal will display
Stop information dumping
Typing "stop" will cease dumping debug information and the digital input status.
Typing "diquery" will display the status of all digital input once.
To set digital output to connect NO with COMMON, type "DO1=L".
To set digital output to connect NC with COMMON, type "DO1=H".

Typing "erase image" will clear all snapshots saved in Flash memory.
Typing "erase graph" will clear all images used on the homepage. If no new images are
uploaded, the system will switch to text mode and use default images instead.
Typing "lock" will inform Network Camera to fix current network settings. It need not
wait for installation during the next boot.
Typing "unlock" will make Network Camera give up current settings and wait for
installation.
Typing "clear" will make Network Camera restore factory settings but not restart. To
validate new settings, type "reset" to make the system restart.
Typing "reset" will make Network Camera perform a software reset.

A. Troubleshooting
After the power has been turned on, Network Camera will perform a self-diagnostic to
detect any hardware defects. The following table lists the LED patterns in general
conditions. In case of any fatal error, the LED will blink in another pattern.
During self-diagnostic after power on Blink in interchanged green and red
Ethernet signal is lost Steady red till Ethernet is detected
Before network is setup No LED of sign till IP address is set
After network is setup Blink green once per second
Any hardware failure Other patterns
Sometimes resetting the system can make the system

back to normal state. If the system still has problems after
reset, restore the factory settings and install again.
RESET: Poke the wrench to click on the button.
self-diagnostic starts.
Restore the factory defaults will lose any previous settings. Reset or restore the
system after power on.
Condition LED color

Q Why can’t I see the Network Camera in the installer after reboot?
A The installer is only used to install the IP address of Network Camera. If the IP address
is fixed by checking the option in the installer, the Network Camera will no longer appear
in the installer.
Q Why can’t I connect the Network Camera after reboot?
A If the IP address is not fixed, Network Camera will always wait for installing command
for a valid IP address. That means the previous IP address will not be used if the option
in the installer is not checked; or the option in the network configuration is not cleared.
The benefit of waiting for a valid IP address by default is that administrators can find the
Network Camera in the installer to prevent IP conflict. As long as the IP address is
confirmed, it is suggested to fix the IP address to make Network Camera automatically
start up whenever regaining power.
Q What if I forget my password?
A Every access to Network Camera needs authentication. If you are not a permitted user,
you may view the images or control the camera as long as the demo account is opened.
The demo account user may use username as “demo” without any password to access
limited features. If you are one of the managed users, you have to ask the administrators
for the password. If you are the administrator, there is no way to recover the root
password. The only way to regain access to Network Camera is to restore the factory
settings and reinstall it.
Q Why can’t I watch video from Network Camera after it is authenticated?
A There are many possible scenarios regarding this problem,
the video input is enabled and the video modulation in Configuration page.
time using Internet Explorer, adjust the security level of Internet Explorer to allow
installation of the plug-in.
allows.
public.

Q How can I use a name instead of the IP address to connect Network Camera?
A To allow users to connect to Network Camera through an easily memorized name, the
administrators must first configure the name server in his network. Here is an example:
the administrator installs the Network Camera with a reserved IP address and assigns it
with a name in the domain name service, then users can connect to Network Camera by
typing a name instead of IP address. If there is DHCP service in the network, the IP
address must be excluded in the DHCP service to prevent from IP conflict.
Q What is the plug-in for?
A The plug-in provided by Network Camera is used to display motion pictures on Internet
Explorer that does not support server push technology. If your system does not allow
installation of any plug-in software, the security level of web browser may need to be
lowered. It is recommended that you consult your network supervisor in your office
regarding the adjustment of the security level.
Q Why is the timestamp different from the system time of my PC or notebook?
A The timestamp is based on the system time of Network Camera. It is maintained by a
real-time clock inside and automatically synchronizes with the time server if Network
Camera is connected to the Internet and the function is enabled. Differences of several
hours may result from the time zone setting.
Q Why does the image not refresh regularly?
A In a modem environment, it is because the bandwidth of PPP connection is far less
than Ethernet. If the difference of the timestamp is not stable, adjust the UART FIFO
lower in both receiving and transmitting from modem property in the control panel.
While in Ethernet, it may be due to time taken in storing snapshots into memory upon
events occurring.
Q How many users are allowed to watch Network Camera at the same time?
A To achieve the best effect, Network Camera will allow twenty users to connect at the
same time. Excess users can get an auto-refreshed still image in homepage instead. It is
recommended to build another web server to host a large quantity of users by retrieving
images from Network Camera periodically.
Q How fast is the video rate of Network Camera?
A The JPEG codec can process 30 frames per second internally. However the total
performance is subject to many coefficients as follows,

In general, the transfer rate in general local network environment can achieve over 200
kilobytes per second and approximately 10 to 20 pictures of normal environment per
second. The general frame size is illustrated in the follow table for reference.

Quality setting Size of each frame Bandwidth demand for 30fps
Q How can I keep Network Camera as private as possible?
A Network Camera is designed for surveillance purpose and has many flexible interfaces.
The user authentication and special confirmation in installation can keep Network
Camera from unauthorized access. You may also change the HTTP port to non-public
number. You can check system log to examine any abnormal activities and trace the
origins.
Q Why can I see image files when I use dir in FTP even if the alarm is not triggered?
A Every time Network Camera starts, it will capture the images as vpre.jpg. If there are
previously saved image files that are not retrieved, Network Camera will keep them until
they are accessed.
Q How will the stored images be processed if Network Camera loses power?
A If user has defined the snapshot interval, Network Camera will capture images
periodically. Once the pre-defined condition is match, the pre-alarm images will be kept
and the current images will be saved. The subsequent images will be stored as
post-alarm stage. User may retrieve these files either by downloading via FTP or direct
Network Camera send them in e-mails. That means after monitoring conditions are met,
Network Camera will keep these image files until user retrieval even if power is lost.
Q If I set Network Camera to send e-mails of images whenever the conditions are met,
will my e-mail account overflow?
A It is recommended to use transient state rather than steady state. For instance, use

‘Input is Rising’ and ‘Input is Falling’ rather than ‘Input is High’ and ‘Input is Low’ to let
the condition be triggered only when state is changed.
Q The image is not clear enough. Is anything broken?
A The lens can be fine adjusted by rotating the outer ring. Please rotate it clockwise or
counter-clockwise to focus near or far.

Customers can frequently check the appropriate product folder on our web site to
download the latest firmware. Only administrators can upgrade the system firmware of
Network Camera.
Run the Upgrade Wizard included in the product CDROM and proceed by the prompts.
Refer to the user's guide of Upgrade Wizard for details.
appear.
FLASH.BIN exists.
1.5 mega bytes. It will take approximately 2 seconds in a local network, 2 minutes by
null modem connection or 6 minutes by modem, but still subject to user's network.
software in Flash memory and restart automatically. When Network Camera starts
writing firmware, both status LED indicators will stay on until system restarts. It takes
about 30 to 40 seconds. User must keep the power stable during the update process.
After the system restarts, Network Camera may need installation depending on whether
the “Reset network at next boot” option is enabled or not. After Network Camera boots
up, reload the web page in the browser.
If power fails during the software upgrade, the program in the memory of Network
Camera may be destroyed permanently. If Network Camera cannot restart properly, ask
the dealer for technical service.

For some customers who already have their own web site or web control application,
Network Camera can be easily integrated through convenient URL. This section lists the
commands in URL format corresponding to the basic functions of Network Camera. Some
RFC standards related to HTML may be a good reference for implementation of the
customized homepage.
The configuration page has a frame layout including option list frame and an option page
frame. Referenced URL except for the configuration page directs to option page frame
only. Some pages, like image quality setting and preset setting, are opened in new
windows for preview.
These URLs can be accessed only by administrators.

There are some images used on the homepage when the homepage layout is in image
mode. Administrators may use the following links to show the images saved in Network
Camera on another page. To change the logo or the background images referenced by
the URL, refer to the homepage layout section in configuration.

Resource name Referenced URL
system logo image /logo.gif
background image /back.gif
button image for configuration /btn_conf.gif
icon image for link indicator /btn_text.gif

Every configuration can be set through URL with POST method by administrators only.
System configuration URL

zone GMT±:00 time zone, n ranged from 0 to 12 Security configuration URL

ptzallowed allow user to view PT scanner panel
deluser


demoioallowed allow demo user to control the I/O
delay refresh time in snapshot mode

smtp1 primary SMTP server
smtp2 secondary SMTP server


ftp1 primary FTP server
ftp2 secondary FTP server
ftprp2 secondary FTP server port

Half x 2 set size to half x 2
Standard x 2 set size to standard x 2

Excellent highest resolution


save save the parameters


inv set inverse mode in weekly schedule


ioalarm trigger DO when DI condition matched
suffix FTP file with date and time suffix



While setting the time zone in automatic date/time synchronization, find the hour offset
in the followings for your region. GMT stands for Greenwich Mean Time, which is the
global time that all time zones are measured from.
(GMT–12:00) International Date Line West
(GMT-11:00) Midway Island, Samoa
(GMT-10:00) Hawaii
(GMT-09:00) Alaska
(GMT-08:00) Pacific Time (US & Canada), Tijuana
(GMT-07:00) Arizona
(GMT-07:00) Chihuahua, La Paz, Mazatlan
(GMT-07:00) Mountain Time (US & Canada)
(GMT-06:00) Central America
(GMT-06:00) Central Time (US & Canada)
(GMT-06:00) Guadalajara, Mexico City, Monterrey
(GMT-06:00) Saskatchewan
(GMT-05:00) Bogota, Lima, Quito
(GMT-05:00) Eastern Time (US & Canada)
(GMT-05:00) Indiana (East)
(GMT-04:00) Atlantic Time (Canada)
(GMT-04:00) Caracas, La Paz
(GMT-04:00) Santiago
(GMT-03:30) Newfoundland
(GMT-03:00) Brasilia
(GMT-03:00) Buenos Aires, Georgetown
(GMT-03:00) Greenland
(GMT-02:00) Mid-Atlantic
(GMT-01:00) Azores
(GMT-01:00) Cape Verde Is.
(GMT+01:00) Amsterdam, Berlin, Bern, Stockholm, Vienna
(GMT+01:00) Belgrade, Bratislava, Budapest, Ljubljana, Prague
(GMT+01:00) Brussels, Copenhagen, Madrid, Paris
(GMT+01:00) Sarajevo, Skopje, Warsaw, Zagreb
(GMT) Casablanca, Monrovia

(GMT+10:00) Hobart
(GMT+10:00) Vladivostok
(GMT+11:00) Magadan, Solomon Is., New Caledonia
(GMT+12:00) Auckland, Wellington
(GMT+12:00) Fiji, Kamchatka, Marshall Is..
(GMT+13:00) Nuku’alofa

System CPU: Trimedia PNX1300 RAM: 16MB SDRAM ROM: 2MB FLASH ROM Networking Adjustable bandwidth limit Protocol TCP/IP, HTTP, SMTP, FTP, Telnet, NTP, DNS and DHCP Modem PPP (dial-up, direct cable connection) Physical 10BaseT Ethernet or 100BaseT Fast Ethernet Video Algorithm Supported MJPEG Features Adjustable image size and quality B/W or color control Timestamp and text overlay Resolution IP2112 Up to 30 frames at 176x112 Up to 30 frames at 352X240 Up to 9 frames at 704X480 IP2122 Up to 25 frames at 176x144 Up to 25 frames at 352X288 Up to 8 frames at 704X576 Camera Specification 1/4 inch color CCD image sensor 1 Lux/F2.0 AGC, AWB, AES IP2112
Dimension 168.5mm(L) *73.6mm(W) * 57.3mm(H) Weight Net. 376 g. Power Consumption: near 5.4W Input: 100-240VAC, 50/60Hz, 0.4A Output: 12VDC, 1.5A Operating Environment Temperature: 0-50°C/32-122°F Humidity: 95%RH EMI & Safety CE, FCC Viewing System Requirement Internet Explorer 4.x or above, Netscape Navigator 4.x or above
- Resolution: 512(H)x492(V) - Electroic shutter. 1/50 ~ 1/100.000sec General I/O 1 sensor inputs (max. 12VDC 50mA) 1 relay outputs (max. 24VDC 1A, 125VAC 0.5A) LED Indicator System status indicator

USA - This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a partial installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the seperation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
-- Consult the dealer or an experienced radio/TV technician for help.
Shielded interface cables must be used in order to comply with emission limits.
- This digital equipment fulfills the requirement for radiated emission according to
limit B of EN55022/1998, and the requirement for immunity according to EN50082-1/1992.
Vivotek Inc. cannot be held responsible for any technical or typographical errors and reserves the
right to make changes to the product and manuals without prior notice. Vivotek Inc. makes no
warranty of any kind with regard to the material contained within this document, including, but
not limited to, the implied warranties of merchantability and fitness for a particular purpose.
Rev. 1.0 Made in Taiwan. ©Copyright 2003. All rights reserved.
Europe
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.