
10BASE-T Module Installation Guide
3Com Corporation 118 Turnpike Road Southborough, MA 01772-1886
® · Document Number 17-00232-3 · Printed February 1996

Federal Communications Commission Notice
VCCI Class 1 Compliance

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you must correct the interference at your own expense.
This equipment is in the 1st Class category (information equipment to be used in commercial or industrial areas) and conforms to the standards set by the Voluntary Control Council for Interference by Information Technology Equipment aimed at preventing radio interference in commercial or industrial areas.
Consequently, when the equipment is used in a residential area or in an adjacent area, radio interference may be caused to radio and TV receivers, and so on.
Cet appareil numérique respecte les limites de bruits radioélectriques applicables aux appareils numériques de Classe A prescrites dans la norme sur la matériel brouilleur: "Appareils Numériques", NMB-003 édictée par le Ministère des Communications.
Read the instructions for correct handling.
UK General Approval Statement
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the interference-causing equipment standard entitled "Digital Apparatus", ICES-003 of the Department of Communications.
The ONcore Switching Hub, ONline System Concentrator, and ONsemble StackSystem Hub are manufactured to the International Safety Standard EN 60950 and are approved in the UK under the General Approval Number NS/G/12345/J/100003 for indirect connection to the public telecommunication network.
VDE Class B Compliance
Hiermit wird bescheinigt, dass der 5124M-TPCL in Üebereinstimmung mit den Bestimmungen der Vfg 243/1991 funkentstöert ist.
The information in this document is subject to change without notice and should not be construed as a commitment by 3Com Corporation. 3Com Corporation assumes no responsibility for any errors that may appear in this document.
Der Deutschen Bundespost wurde das Inverkehrbringen dieses Geraetes angezeigt und die Berechtigung zur Üeberprüefung der Serie auf Einhaltung der Bestimmungen eingeräeumt.
Einhaltung mit betreffenden Bestimmugen kommt darauf an, dass geschirmte Ausfuehrungen gebraucht werden. Fuer die Beschaffung richtiger Ausfuehrungen ist der Betreiber verantwortlich.
© 1996, by 3Com Corporation. Printed in U.S.A. All rights reserved. 3Com is a registered trademark of 3Com Corporation. ONcore is a registered trademark of 3Com Corporation. The information contained herein is the exclusive and confidential property of 3Com Corporation. No part of this manual may be disclosed or reproduced in whole or in part without permission from 3Com Corporation.
This is to certify that the 5124M-TPCL is shielded against radio interference in accordance with the provisions of Vfg 243/1991.
The German Postal Services have been advised that this equipment is being placed on the market and that they have been given the right to inspect the series for compliance with regulations.
Compliance with applicable regulations depends on the use of shielded cables. The user is responsible for procuring the appropriate cables.
Because of the nature of this material, numerous hardware and software products are mentioned by name. In most, if not all cases, these product names are claimed as trademarks by the companies that manufacture the products. It is not our intent to claim these names or trademarks as our own.
This equipment conforms to the Class A emissions limits for a digital device as defined by EN55022 (CISPR22).
Artel, Chipcom, Ethermodem, Galactica, ONcore, ORnet, StarBridge, and TriChannel are registered trademarks of 3Com Corporation.
Chipcom OpenHub, G-Man, LANsentry, MultiProbe, ONdemand, ONline, ONsemble, PowerRing, SL2000, SL3000, SL4000, StackJack, StackSystem, and SwitchCentral are trademarks of 3Com Corporation.
ii ONline Ethernet 24-Port 10BASE-T Module Installation and Operation Guide

The Chipcom Multichannel Architecture Communications System is registered under U.S. Patent Number 5,301,303.
XNS is a trademark of Xerox Corporation.
DEC, DECnet, the Digital logo, DELNI, POLYCENTER, VAX, VT100, and VT220 are trademarks of Digital Equipment Corporation.
IBM is a registered trademark of International Business Machines. NetView is a trademark of International Business Machines.
3ComFacts, Ask 3Com, CardFacts, NetFacts, and CardBoard are service marks of 3Com Corporation.
3Com, LANplex, BoundaryRouting, LanScanner, LinkBuilder, NETBuilder, NETBuilderII, ParallelTasking, ViewBuilder, EtherDisk, Etherl\Link, EtherLink Plus, EtherLink II, TokenLink, TokenLink Plus, and TokenDisk are registered trademarks of 3Com Corporation.
3ComLaser Library, 3TECH, CacheCard, FDDILink, FMS, NetProbe, SmartAgent, Star-Tek, and Transcend are trademarks of 3Com Corporation.
CompuServe is a registered trademark of CompuServe, Inc.
3Com registered trademarks are registered in the United States, and may or may not be registered in other countries. Other brand and product names may be registered trademarks or trademarks of their respective holders.
Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (c)(1) (ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013.
Printed on recycled paper.
ONline Ethernet 24-Port 10BASE-T Module Installation and Operation Guide iii
Restricted Rights

iv ONline Ethernet 24-Port 10BASE-T Module Installation and Operation Guide

Audience xiii Structure of This Guide xiv Document Conventions xv Related Documents xvi
3Com Documents xvii Reference Documents xvii
Ethernet 24-Port 10BASE-T Module Description 1-1
Module Features 1-2
Bank Switching Capability 1-3 Model Number 5124M-TPCL Features 1-3 Model Number 5124M-TP Features 1-4 Theory of Operation 1-4
Understanding the General Rules 2-2
Rules for Configuring a Network 2-2 LAN Equivalence 2-6 Choosing a Network Backbone Cabling Structure 2-7
Building a Network (Star Configuration) 2-8 Building a Network (Serial Configuration) 2-9 24-Port Module Configurations 2-10 Fiber Backbone, 10BASE-T To-The-Desk 2-10 10BASE-T Backbone, 10BASE-T To-The-Desk 2-12 Using Patch Panels 2-14 Establishing Fault-Tolerant Configurations 2-14
Setting Port Redundancy 2-15
Configuring Ports for Fault Tolerance 2-15
ONline Ethernet 24-Port 10BASE-T Module Installation Guide v

Setting Backbone Redundancy 2-15
Redundant Twisted Pair Backbone 2-16
Precautionary Procedures 3-2 Quick Installation 3-2 Unpacking Procedures 3-4 Setting the DIP Switches 3-4
DIP Switch Overview 3-5 DIP Switch Description 3-7 Installing the Module 3-10
Using 90° Cable Connectors 3-13
Installing the Cable Tie-Wrap Kit 3-13 Securing 90° Cables to the Module 3-15 Configuration in a Managed Environment 3-17
If Management is Not Available 3-18 Before Configuring the Module 3-19 Enabling Ports 3-19 Enabling Port Redundancy 3-19 Enabling Link Integrity 3-20 Selecting a Network 3-20 Enabling Remote Diagnostics Mode 3-21 Setting the Autopartition Threshold Value 3-22 Saving Module Configurations 3-23 Showing Module Configurations 3-23
Show Module 3-24 Show Port 3-25 Gathering Network Statistics 3-27
Selecting the Per-Port Counters Connector 3-28 Monitoring the Front Panel 3-29 Verifying LED and Network Assignments 3-32
Using the LED Check Button 3-32
vi ONline Ethernet 24-Port 10BASE-T Module Installation Guide

Troubleshooting Using the Port Status and Port Activity LEDs 4-2
Troubleshooting Using the Port Status LEDs 4-2 Troubleshooting Using the Port Activity LEDs 4-4 Technical Assistance 4-4
General Specifications A-2 Power Specifications A-3 Environmental Specifications A-4 Mechanical Specifications A-5 Twisted Pair Cable and Connector Specifications A-5
Twisted Pair Cable Specifications A-6 Twisted Pair Connector Specifications A-7 RJ-45 Connector Pinouts A-7 50-Pin Connector Pinouts A-8 Connecting Twisted Pair Cables A-12
On-line Technical Support B-1
Email Technical Support B-2 World Wide Web Site B-2 Support from Your Network Supplier B-2 Support from 3Com B-3 Returning Products for Repair B-4 Accessing the 3Com MIB B-4 3Com Technical Publications B-5
ONline Ethernet 24-Port 10BASE-T Module Installation Guide vii

viii ONline Ethernet 24-Port 10BASE-T Module Installation Guide

Figure 1-1. Typical 24-Port Module Configuration 1-5 Figure 2-1. Star-Wiring Configuration 2-8 Figure 2-2. Serial Configuration 2-9 Figure 2-3. Sample Configuration Distance Calculation Using 24-Port Modules 2-11 Figure 2-4. Unshielded Twisted Pair Network Using 24-Port Modules .2-13 Figure 2-5. Redundant Twisted Pair Configuration Using 24-Port Modules 2-16 Figure 3-1. Model 5124M-TPCL and Model 5124M-TP DIP Switch Location 3-6 Figure 3-2. Installing a 24-Port Module (Model Number 5124M-TPCL) 3-11 Figure 3-3. 24-Port Module Cable Connection (Model Number 5124M-TPCL) 3-12 Figure 3-4. Attaching the Tie-Wrap Bracket to the Module 3-14 Figure 3-5. Attaching Cables With 90° Connectors (Model Number 5124M-TPCL) 3-15 Figure 3-6. Attaching Cables With 90° Connectors 3-16 Figure 3-7. 24-Port Module Faceplate and ONline System Concentrator (Model Number 5124M-TPCL) 3-29 Figure 3-8. 24-Port Module Faceplate and ONline System Concentrator (Model Number 5124M-TP) 3-30 Figure A-1. 24-Port Module RJ-45 Connector Pinouts A-8 Figure A-2. 50-Pin Male and Female Connectors A-9
ONline Ethernet 24-Port 10BASE-T Module Installation Guide ix

x ONline Ethernet 24-Port 10BASE-T Module Installation Guide

Table 2-1. Seven Basic Network Rules 2-3 Table 2-2. LAN Product Equivalent Distances 2-6 Table 3-1. Procedures for Completing Installation 3-2 Table 3-2. DIP Switch Settings 3-8 Table 3-3. Channel (Network) Select DIP Switch Settings 3-9 Table 3-4. 24-Port Module LED Interpretations 3-31 Table 3-5. Network Check Codes 3-33 Table 4-1. Troubleshooting Using the Port Status LEDs 4-2 Table 4-2. Troubleshooting Using the Port Activity LEDs 4-4 Table A-1. 24-Port Module General Specifications A-2 Table A-2. 24-Port Module Power Specifications A-3 Table A-3. 24-Port Module Fuse Specifications A-4 Table A-4. 24-Port Module Environmental Specifications A-4 Table A-5. 24-Port Module Mechanical Specifications A-5 Table A-6. IBM Twisted Pair Cable Specifications A-6 Table A-7. 50-Pin Cable Pinouts and Port Assignments A-10
ONline Ethernet 24-Port 10BASE-T Module Installation Guide xi



This guide tells you how to install and operate the 3Com ONline™ Ethernet 24-Port 10BASE-T Module for the ONline System Concentrator. It also includes information on monitoring this module using an ONline network management module. An appendix explains cabling guidelines and options for this module.
This guide is intended for the following people at your site:
K Network manager or administrator
ONline Ethernet 24-Port 10BASE-T Module Installation Guide xiii
K Hardware installer

This guide contains the following chapters:
Chapter 1, Introduction – Introduces the functions and features of the ONline Ethernet 24-Port 10BASE-T Module.
Chapter 2, Designing and Expanding the Network – Shows possible network configurations using the ONline System Concentrator and the ONline Ethernet 24-Port Module.
Chapter 3, Installing and Operating the Module – Provides illustrated procedures for installing the 24-Port Module into the ONline System Concentrator. Also shows front panel LEDs and dip switches on the module and describes network management commands.
Chapter 4, Troubleshooting – Provides help in isolating and correcting problems that may arise when installing or operating this module.
Appendix A, Specifications – Provides electrical, environmental, and mechanical specifications, plus information on 50-pin Telco-type connectors, RJ-45 connectors, and twisted pair cables.
Appendix B, Technical Support – Lists the various methods for contacting the 3Com technical support organization and for accessing other product support services.
xiv ONline Ethernet 24-Port 10BASE-T Module Installation Guide
Index

The following document conventions are used in this manual:
Courier text User input In the Agent Information Form, enter MIS in the New Contact field.
System output After pressing the Apply button, the system displays the message Transmitting data.
Path names Before you begin, read the readme.txt file located in /usr/snm/agents.
Italic text in braces User-substituted identifiers
Use the following command to show port details:
SHOW PORT {slot.all} VERBOSE
Capitalized text in plain brackets
Keyboard entry by the user
Type your password and press [ENTER].
Italics Text emphasis, document titles
Ensure that you press the Apply button after you add the new search parameters.
ONline Ethernet 24-Port 10BASE-T Module Installation Guide xv
Convention Indicates Example · Bold command string

condition may threaten personal safety
This section provides information on supporting documentation, including:
xvi ONline Ethernet 24-Port 10BASE-T Module Installation Guide
Convention Indicates Example · K 3Com Documents · K Reference Documents

The following documents provide additional information on 3Com products:
17-Slot ONline System Concentrator Installation and Operation Guide – Explains how to install, operate, and manage the 3Com ONline 17-Slot System Concentrator (Models 5017C-LS and 5017C with load sharing).
6-Slot ONline System Concentrator Installation and Operation Guide – Explains how to install, operate, and manage the 3Com ONline 6-Slot System Concentrator.
ONline Ethernet Management Module Installation and Operation Guide – Describes how to install the ONline Ethernet Management Module in the ONline System Concentrator and explains the LEDs on the module faceplate. This guide also provides instructions for connecting a terminal to the module and describes the management commands necessary to perform management tasks on the concentrator and on remote devices.
ONline Management Commands Guide – Provides an alphabetized reference resource describing all ONline management commands.
For a complete list of 3Com documents, contact your 3Com representative.
The following documents supply related background information:
Case, J., Fedor, M., Scoffstall, M., and J. Davin, The Simple Network Management Protocol, RFC 1157, University of Tennessee at Knoxville, Performance Systems International and the MIT Laboratory for Computer Science, May 1990.
Rose, M., and K. McCloghrie, Structure and Identification of Management Information for TCP/IP-based Internets, RFC 1155, Performance Systems International and Hughes LAN Systems, May 1990.
ONline Ethernet 24-Port 10BASE-T Module Installation Guide xvii



This chapter introduces you to the 3Com ONline™ Ethernet 24-Port 10BASE-T Modules (Model Numbers 5124M-TPCL and 5124M-TP). The modules are referenced throughout this guide as the 24-Port Module.
You can install both versions of the 24-Port Module in all 3Com ONline System Concentrator and ONcore® Switching Hub models.
This chapter contains the following sections:
K Ethernet 24-Port 10BASE-T Module Description
K Theory of Operation
This section describes:
K Model Number 5124M-TPCL Features
K Model Number 5124M-TP Features
Introduction 1 - 1
K Module Features

The ONline Ethernet 24-Port Module is an IEEE 802.3 repeater module that complies with the 10BASE-T standard. It connects up to 24 devices (PCs, terminals, printers, modems) to the ONline System Concentrator.
The 24-Port Module (Model Number 5124M-TPCL and Model Number 5124M-TP) is a bank switching module. Bank switching is the assignment of a group of 12 consecutive ports to a single network, or to an isolated network.
The ONline Ethernet 24-Port 10BASE-T Module:
K Is an IEEE 802.3 repeater module that complies with the 10BASE-T standard.
K Connects up to 24 devices (PCs, terminals, printers, modems) to the 3Com ONline System Concentrator or ONcore Switching Hub.
K Provides high port density at a low cost per port.
K Supports up to 100 meters on 10BASE-T-compliant unshielded twisted pair (UTP) or shielded twisted pair (STP) wiring.
K Features “hot swap” capability so that you can install or remove the module without having to power down the concentrator.
K Provides bank-switching capability.
K Provides a user-selectable autopartition threshold for flexibility in dealing with collision-related network slowdowns.
K Allows you to disable Link Integrity so you can connect to equipment that does not conform to the 10BASE-T standard.

K Is designed with all ports internally crossed over, as required by the 10BASE-T standard. This enables you to connect the 24-Port Module to a 10BASE-T transceiver without using an external crossover adapter.
Bank switching is the assignment of a group of twelve consecutive ports to a single network, or to an isolated network.
In an unmanaged concentrator you can use DIP switches to:
K Assign all module ports to an Ethernet network or to an isolated network
K Assign port groups 1 through 12 or 13 through 24 to different Ethernet or isolated networks
In a managed concentrator you can use network management commands to assign the following port “groups” to any of three backplane networks, or to either of two isolated networks:
K Ports 1 through 12
K Ports 13 through 24
K All ports on the module
Model Number 5124M-TPCL permits you to connect groups of 12 consecutive 10BASE-T-compliant module ports using:
K Two 50-pin Telco connectors (one connector attached to 12 ports)
K Two 25-pair 10BASE-T cables or two 12-leg “hydra” cables (one cable per 12 ports)
Introduction 1 - 3

Model Number 5124M-TP permits you to connect individual 10BASE-T-compliant ports using 24 RJ-45 connectors (one connector per port). The RJ-45 connectors provide direct connections to 10BASE-T cables (one cable per connected port).
ONline Ethernet 24-Port 10BASE-T Modules incorporate repeaters and twisted pair transceivers that receive and restore amplitude to incoming signals. 24-Port Module repeaters restore phase and frequency.
Repeated signals:
K Synchronize to the system clock
K Enter on the TriChannel® backplane of the ONline System Concentrator.
Outgoing signals from the TriChannel backplane are:
K Sent directly to transceivers
K Transmitted to twisted pair link segments by the transceivers

Figure 1-1 shows a 24-Port Module (Model Number 5124M-TPCL) connected to nodes by means of bundled 25-pair or 12-leg hydra cables and patch panels.

Figure 1-1. Typical 24-Port Module Configuration
Introduction 1 - 5



This chapter contains configuration information to help you design your network. It describes how to configure networks using the ONline System Concentrator and ONline Ethernet 24-Port 10BASE-T Modules. It also provides examples of network cabling structures and Ethernet network cabling solutions.
This chapter contains the following sections:
K Understanding the General Rules
K Choosing a Network Backbone Cabling Structure
K 24-Port Module Configurations
K Using Patch Panels
K Establishing Fault-Tolerant Configurations
Designing and Expanding the Network 2 - 1

This section describes general rules for configuring an Ethernet network using fiber as the backbone medium. It also provides rules to ensure that your network configuration conforms to distance limitations imposed by Ethernet and networking equipment. Use these guidelines for building your network.
Refer to the sections that follow for specific rules for:
K Determining maximum 24-Port Module fiber link distances
K Connecting various horizontal media types (10BASE-FB, twisted pair) to a 10BASE-FB backbone
K Examples of recommended fault-tolerant configurations
This section describes:
K Rules for Configuring a Network
K Calculating Equivalent Fiber Distances
This section outlines seven basic network rules and 3Com recommendations for building an Ethernet network.

For more hardware-specific information on the 24-Port Module, refer to Appendix A.
Table 2-1. Seven Basic Network Rules
1 If possible, use 10BASE-FB as the backbone medium.
Use 62.5 micron cable to conform with the IEEE 10BASE-F and upcoming ANSI FDDI standards.
Use ST-type connectors.
2 Wire the backbone in a star topology to isolate faults.
Make sure to lay extra fiber cables. The extra cost is small and you will find you need them as your network grows.
The star topology conforms to FDDI wiring as well -- just make sure to run at least two fiber strands to every backbone connection.
3 The maximum Fiber Ethernet network diameter is 4200 meters of fiber cable.
The 4200 meters is the maximum distance between any two transceivers on the network.
The 4200 meters does not include the transceiver cable (that is, drop or patch cable) that connects a device with an external transceiver. Transceiver cables can extend up to 50 meters. Thus, total network diameter can be as much as 4300 meters (4200 m + 2 * 50 m) between any two nodes.
Designing and Expanding the Network 2 - 3
Rule Definition Recommendations/Notes

Table 2-1. Seven Basic Network Rules (Continued)
4 Certain LAN devices on the network shrink the maximum Fiber Ethernet network diameter to less than 4200 meters.
Many LAN products delay the signal that goes through them. This is known as equivalent distance. Every microsecond delay reduces the maximum link distance. In fact, every microsecond delay shrinks the network diameter by approximately 200 meters of fiber cable. Table 2-2 lists the Equivalent Distances for other 3Com products.
5 Assume that one meter of coaxial or twisted pair is equal to one meter of fiber cable.
This is a conservative rule. For example, the actual equivalence is about 1.1 meters of coaxial for every meter of fiber. For simplicity, assume one meter.
Rule Definition Recommendations/Notes

Table 2-1. Seven Basic Network Rules (Continued)
6 The fiber link distances must not exceed the limits imposed by the optical power budget.
In general, on 62.5 micron cable, you can go up to 4000 meters point-to-point using the ONcore or ONline Fiber Modules. If you have poor quality cable or cross many patch panels, you may have to sacrifice some distance.
Some older Ethernet fiber optic products are less powerful than ONcore Fiber Module optics. So when connecting to these products, remember that the least powerful device determines the maximum point-to-point distance.
7 When in doubt, use a bridge.
If you are not certain if you have exceeded allowable network distances, use a bridge to extend the network.
Designing and Expanding the Network 2 - 5
Rule Definition Recommendations/Notes

LAN equivalence is the sum of both the incoming and outgoing module port signals. Different modules, however, have different equivalent distances. Table 2-2 lists the LAN product equivalent distances.
Table 2-2. LAN Product Equivalent Distances
LAN Product Equivalent Distance (meters)
ONcore Ethernet 10-Port 10BASE-FB Module 190
Incoming signal to fiber port 140
Outgoing signal from fiber port 50
ONcore Ethernet 10BASE-T Module 585
Incoming signal to TP port 420
Outgoing signal from TP port 165
ONline Ethernet 10BASE-T Modules 585
Incoming signal to TP port 420
Outgoing signal from TP port 165
ONline Ethernet Fiber or 10BASE-FB Modules 190
Incoming signal to fiber port 140
Outgoing signal from fiber port 50
ONline Ethernet FOIRL Module 560
Incoming signal to fiber port 330
Outgoing signal from fiber port 230
ONline Ethernet Transceiver Module 0
ORnet Star Coupler (8 or 14 port) 26 180

Table 2-2. LAN Product Equivalent Distances (Continued)
LAN Product Equivalent Distance (meters)
ONline Ethernet BNC Module 900
Incoming signal to BNC port 450
Outgoing signal from BNC port 450
ONline Ethernet Repeater Module 800
Incoming signal to AUI port 600
Outgoing signal from AUI port 200
Because of fiber's long-distance capabilities and immunity to noise, 3Com strongly recommends using fiber as the backbone.
This section describes:
K Building a Network (Star Configuration)
K Building a Network (Serial Configuration)
You can implement either of these configuration topologies when connecting your network backbone using 10BASE-FB modules installed in an ONline System Concentrator.
Designing and Expanding the Network 2 - 7
IEEE Repeater 800

Wire your network in a star configuration using an ONline System Concentrator as the central point in the network. Wiring in a star configuration provides two major benefits:
K Faults in the cable plant affect only a piece of the network.
K You can easily expand the size of your network.
Figure 2-1 shows 10BASE-T and 10BASE-FB modules installed in a star-wired network.

Figure 2-1. Star-Wiring Configuration

Use a serial configuration for smaller diameter networks that are not expected to grow. Serial configurations reduce the overall network diameter by 190 meters for each concentrator in any path.
Figure 2-2 shows 10BASE-FB modules installed in a network using a serial configuration.

Figure 2-2. Serial Configuration
Designing and Expanding the Network 2 - 9

This section describes how to define total network size based on the limits of IEEE 802.3 collision detection. This section also describes how to construct a network consisting of a Fiber Backbone and 10BASE-T unshielded twisted pair connections to-the-desk.
This section describes:
K Fiber Backbone, 10BASE-T To-The-Desk
K 10BASE-T Backbone, 10BASE-T To-The-Desk
Be aware of the following additional rules for configuring a network:
K The four-repeater rule in Ethernet limits the number of 10BASE-T modules between any two transceivers. The path from the TP port to the backplane counts as 1/2 of a repeater and the path from the backplane to the TP port counts as 1/2 of a repeater. You must add a bridge if the path from one transceiver to another exceeds the four-repeater rule.
K The equivalent fiber distance for 10BASE-T modules is defined as follows:
– 420 meters for signals that externally enter a 10BASE-T module port
– 165 meters for signals that internally enter a 10BASE-T module through the ONline concentrator backplane
For each pair of 10BASE-T modules that a signal goes through, there is an equivalent fiber distance of 585 meters (420 m + 165 m =585 m). In addition, if a signal makes a roundtrip through a 10BASE-T Module (that is, enters a 10BASE-T port externally and exits through another port on the same 10BASE-T module), that counts as 585 meters of equivalent fiber distance, and as a full repeater.

Use the following example to determine if the 10BASE-T transceivers in Figure 2-3 are within legal Ethernet limits. Identify the two transceivers that are likely to be the greatest fiber equivalent distance apart. In Figure 2-3, they are 10BASE-T transceivers A and B.
Figure 2-3 shows 24-Port Modules installed in each of three concentrators.

Figure 2-3. Sample Configuration Distance Calculation Using 24-Port Modules
To determine if your network configuration is legal:
Designing and Expanding the Network 2 - 11

For the configuration shown in Figure 2-3 to work, ensure the equivalent fiber distance between Transceiver A and Transceiver B is less than 4200 meters.
As shown in the calculation, there are still 1510 meters left for expansion in this configuration. Therefore, this configuration is legal.
In constructing a twisted pair backbone:
K Ensure there are no more than eight 10BASE-T modules in the path between any two transceivers (Ethernet four-repeater rule). Each 10BASE-T module counts as 1/2 of a repeater unless the signal goes in one port and out another port on the same module. In that case, the module counts as a full repeater.
K Add a bridge if you have more than eight 10BASE-T modules serially connected. Each bridge creates a subnetwork. Each subnetwork can have its own 4200 meter network diameter.
Figure 2-4 shows a possible unshielded twisted pair network using 24-Port Modules and 24-gauge cable.


Figure 2-4. Unshielded Twisted Pair Network Using 24-Port Modules
The equivalent fiber distance can be calculated as follows:
Total link distance: 100 m + 100 m + 100 m + 50 m + 20 m = 370 m
Total equivalent distance of the 24-Port Modules: 4 * 420 m + 4 * 165 m = 2340 m (signal externally enters 4 Twisted Pair Modules: 4 * 420 m) (signal internally enters 4 Twisted Pair Modules from the backplane: 4 * 165 m)
Because the total equivalent distance (2710 m) is less than 4200 meters, this configuration is legal.
Designing and Expanding the Network 2 - 13

Patch panels weaken signals that pass through them, thereby reducing achievable link distances. 3Com assumes the use of one patch panel in the 100 meter link distance calculations specified in this installation guide. Each additional patch panel in the link reduces the 100 meter link distance by approximately 10 meters.
In Figure 2-4:
K If two patch panels were used between the top right PC and the top right concentrator, the link distance of 100 meters would have to be shortened to 90 meters.
K The link distance would have to be shortened to 90 meters because the maximum allowable link distance on 24-gauge wire using 10BASE-T signaling with two intervening patch panels is 100 meters minus approximately 10 meters.
K A patch panel installed between the bottom right PC and the bottom left concentrator would not affect the link because it is only 20 meters away.
You can establish fault tolerance for any port on the 24-Port Module, for selected portions of the network backbone, or for the entire network backbone.
This section describes:
K Setting Port Redundancy
K Setting Backbone Redundancy

When you enable redundancy between two ports, the ports are automatically enabled. Once port redundancy is enabled:
K Port 1 is the primary link, which passes data.
K Port 2 is the redundant link, which does not pass data in either direction. However, the link is monitored for any failures (the Port Status LED indicates any problems).
You can configure the 24-Port Module ports in one of three different ways:
K Normal Configuration - All ports operate as independent cable ports.
K Flexible Redundant Configuration - You can arbitrarily assign primary and backup ports to any pair of ports. You can configure this mode only through the advanced management commands provided with the Ethernet Management Module Version v3.0 or later.
K Normal and Redundant Configuration - You can enable redundancy between one set of ports and have the remaining ports operate as independent ports.
For maximum backbone tolerance, connect both the primary and backup ports back to the central concentrator (refer to Figure 2-5). This configuration allows the backup port to automatically take over if the primary link fails.
Designing and Expanding the Network 2 - 15

You can implement twisted pair link redundancy between ONline System Concentrators using network management.
Figure 2-5 shows an example of a redundant configuration between concentrators using 24-Port Modules.

Figure 2-5. Redundant Twisted Pair Configuration Using 24-Port Modules
To set link redundancy between two 24-Port Modules (refer to Figure 2-5):

Once redundancy is configured, a switchover occurs under two conditions:
The switchover occurs when the primary link fails.
A switchover back to the primary link happens automatically once the problem is resolved.
Refer to the appropriate network management module installation and operation guide for information on setting redundancy between 24-Port Module ports.
Designing and Expanding the Network 2 - 17
K Link failure · K Port partition



This chapter describes installation procedures for the ONline Ethernet 24-Port 10BASE-T Modules (Model Number 5124M-TPCL and Model Number 5124M-TP).
This chapter contains the following sections:
K Setting the DIP Switches
K Installing the Module
K Configuration in a Managed Environment
K Saving Module Configurations
K Showing Module Configurations
K Gathering Network Statistics
K Monitoring the Front Panel
K Verifying LED and Network Assignments
Installing and Operating the Module 3 - 1
K Precautionary Procedures · K Quick Installation · K Unpacking Procedures

Electrostatic discharge (ESD) can damage static-sensitive devices on circuit boards. Follow these precautions when you handle the 24-Port Module.
K Do not remove the board from its antistatic shielding bag until you are ready to inspect or install it.
K Handle the board by the faceplate only.
K Use proper grounding techniques when you install the 24-Port Module. These techniques include:
– Using a foot strap and grounded mat or wearing a grounded static discharge wrist strap.
– Touching the grounded rack or other source of ground just before you handle a 24-Port Module.
Table 3-1 outlines the steps for installing your module. If you are familiar with installing ONline modules, you may want to use this table as a checklist. Otherwise, consult the remainder of this chapter.
Table 3-1. Procedures for Completing Installation
Step Procedure Section Title
1 Verify that your network complies with the basic rules for network design.
Chapter 2, Designing and Expanding the Network
2 Unpack the module. Chapter 3, Unpacking Procedures section

Table 3-1. Procedures for Completing Installation
Step Procedure Section Title
3 If you do not have a management module installed in the concentrator, configure the DIP switch settings to your specifications.
Chapter 3, Setting the DIP Switches section
4 If you have Model Number 5124M-TPCL, insert the module into a single open slot in the concentrator and tighten the faceplate screws.
Chapter 3, Installing the Module section
If you have Model Number 5124M-TP, insert the module into two consecutive empty slots in the concentrator and tighten the faceplate screws.
5 Establish connections from the 24-Port Module to devices or to a 10BASE-T transceiver using the appropriate connectors and cabling.
Chapter 3, Installing the Module section
6 If you have a management module installed in the concentrator, configure the module using the management commands.
Chapter 3, Configuring the Module section
7 Verify LED status for normal operation.
Chapter 3, Verifying LED and Network Assignments section
Installing and Operating the Module 3 - 3

When unpacking your 24-Port Module:
This section describes:
K DIP Switch Overview
K DIP Switch Description

The 24-Port Module has a single switch located on the module. This switch contains 10 DIP switches that let you:
K Assign 12-ports on each 50-pin connector to a network (Model Number 5124M-TPCL)
K Assign 12 ports on each Double Stack RJ-45 connector to a network(Model 5124M-TP)
K Enable or disable all ports on each connector
K Establish Link Integrity for each connector (or group of 12 ports)
K Isolate all ports on one connector (or group of 12 ports)
K Isolate all ports on both connectors. This setting isolates the module from the backplane.
Note: All DIP switch settings on the 24-Port Module are ignored if an ONline management module (EMM Version v3.2 or later [for Model Number 5124M-TPCL] EMM Version v4.3 or later [for Model Numbner 5124M-TP]) is already installed in the concentrator. 3Com recommends that you use network management commands to configure the module instead of the DIP switches. To override management and configure the module to DIP switch settings in a managed hub, enter the SET DEVICE DIP_CONFIGURATION command.
Installing and Operating the Module 3 - 5

Figure 3-1 shows the location of the DIP switch component on the 24-Port Module.

Figure 3-1. Model 5124M-TPCL and Model 5124M-TP DIP Switch Location

DIP switches are labeled 1 through 10 (refer to Figure 3-1). DIP switches 1 through 4 enable features for connector 1 (CONN 1). DIP switches 5 through 8 enable features for connector 2 (CONN 2). DIP switch 9 isolates all ports (both connectors) from the backplane, or 12 ports on either connector. Modules or ports set to the same network communicate with each other.
Installing and Operating the Module 3 - 7

Tables 3-2 and 3-3 describe DIP switch settings. For a complete definition of each DIP switch function, refer to the section Configuring the Module later in this chapter.
Table 3-2. DIP Switch Settings
DIP Switch Label Function Factory Default
Select Connector 1 Network
See Table 3-3.
3 PORT EN Enable/DisableC onnector 1 Ports
4 LI EN Enable/Disable Connector 1 Link Integrity
Select Connector 2 Network
See Table 3-3.
7 PORT EN Enable/Disable Connector 2 Ports
8 LI EN Enable/Disable Connector 2 Link Integrity
9 ISO SEP Isolate One/Both Connectors

The channel select switch settings (switches 1 and 2 for connector 1, and switches 5 and 6 for connector 2) let you select a channel for each connector. To reconfigure the module to a different channel, refer to the information in Table 3-3.
Table 3-3. Channel (Network) Select DIP Switch Settings
DIP Switch Setting (CONN 1)
DIP Switch Setting (CONN 2)
Switch 1 Switch 2 Switch 5 Switch 6 Network Selection
On 1 (default)
Off On Off On 2
On Off On Off 3
Off Isolated (connector operates independent of the three backplane networks)
Installing and Operating the Module 3 - 9

You do not need to power down the ONline System Concentrator to install the 24-Port Module. You can insert the module while the concentrator is operating (this is called a hot swap).
To install a 24-Port Module:
K If network management is not available, set the DIP switches on the board (if different than the default values). Refer to Table 3-2 and Table 3-3 for an explanation of the DIP switch settings.
K If a network management module is installed in your concentrator:
– If your management module is not EMM Version v4.3 or later (for Model Number 5124M-TP) or EMM Version v3.2 or later (for Model Number 5124M-TPCL), it does not support the particular 24-Port Module. Enter the SET DEVICE DIP_CONFIGURATION command to configure the 24-Port Module from DIP switch settings.
– If your management module is at the appropriate software level, go to step 2 and complete the installation, then configure the 24-Port Module using the commands described in the Configuring the Module section.
For Model Number 5124M-TP, locate two adjacent open slots in the concentrator. If there are no adjacent open slots, remove two adjacent blank panels on the concentrator to expose the slots you need to install the module.

Figure 3-2 shows the installation of a 24-Port Module.

Figure 3-2. Installing a 24-Port Module (Model Number 5124M-TPCL)
Installing and Operating the Module 3 - 11


Figure 3-3. 24-Port Module Cable Connection
K A 10BASE-T transceiver
K A patch panel
K A 10BASE-T adapter card
(Model Number 5124M-TPCL)

3Com recommends that you use 180° connectors with the 5124M-TPCL model. Because of the proximity of the two connectors, you must follow the special steps described below if you decide to use 90° (right-angle) connectors.
This section describes:
K Installing the Cable Tie-Wrap Kit
K Securing 90° Cables to the Module
A cable tie-wrap kit is included with the 24-Port Module. If you use a cable connector other than a 180° cable connector (for example, a 90° cable connector), you must secure the cable to the module connector using the tie-wrap kit.
The tie-wrap kit contains:
K Kit card containing kit part number
K 1 Phillips-head screw
K 1 Tie-wrap bracket
To install the tie-wrap kit:
Installing and Operating the Module 3 - 13
K 3 Tie-wraps


Figure 3-4. Attaching the Tie-Wrap Bracket to the Module

To secure 90° cables to the 24-Port Module connectors:

Figure 3-5. Attaching Cables With 90° Connectors (Model Number 5124M-TPCL)
Installing and Operating the Module 3 - 15


Figure 3-6. Attaching Cables With 90° Connectors

K A 10BASE-T transceiver
K A patch panel
K A 10BASE-T adapter card
With an EMM already installed, all DIP switch settings on the 24-Port Module are ignored. For this reason, 3Com recommends that you use network management commands instead of DIP switches to configure the module.
The following sections describe important module configuration issues and settings you can configure for both models of the 24-Port Module:
K If Management is Not Available
K Before Configuring the Module
K Enabling Port Redundancy
K Enabling Link Integrity
K Selecting a Network
Installing and Operating the Module 3 - 17
K Enabling Ports

K Enabling Remote Diagnostics Mode
K Setting the Autopartition Threshold Value
For additional information on any network management command described in this section, refer to the appropriate ONline Management Module Installation and Operation Guide.
When you first install the 24-Port Module in an unmanaged concentrator, configure the 24-Port Module using the DIP switches as described in the section Setting the DIP Switches. For additional information on all network management features, refer to:
K The appropriate ONline Management Module Installation and Operation Guide, or the ONcore Distributed Management Module User's Guide
K The ONline Management Commands Guide or the ONcore Distributed Management Module Commands Guide

When you first install the 24-Port Module in a managed concentrator:
– Enable ports you want to use
– Assign enabled ports to backplane networks
You can enable or disable each of the ports on the 24-Port Module. When a port is enabled, it can transmit to and receive data from the network (channel) that the module or connector (bank) is assigned to.
To enable a port, use the following network management command:
SET PORT {slot.port} MODE {enable}
{slot.all} {disable}
Network management lets you set redundancy between ports. When you set two ports redundant to each other, the secondary port takes over if the primary port fails.
To set redundancy between ports, use the following management command:
SET PORT {slot.port} MODE {redundant} {slot.port}
Refer to Chapter 2 for an example of port redundancy.
Installing and Operating the Module 3 - 19
{non-redundant}

Use the following guidelines to determine whether to enable or disable Link Integrity:
K Enable Link Integrity for all ports on the 24-Port Module for networks that comply with the 10BASE-T standard.
K Disable Link Integrity only when connecting to older equipment that does not comply with the 10BASE-T standard.
The Link Integrity setting at both ends of a connection must be either enabled or disabled. If Link Integrity settings are not configured to the same setting, the 24-Port Module with Link Integrity enabled reports a Link Integrity error.
The Link Status LED for each connector (bank) will be on solid if the Link Integrity is valid for ports which are both enabled and have Link Integrity enabled. If all enabled ports have Link Integrity testing disabled the LED is also on solid. In all other cases the LED will blink in approximately 1-second intervals.
To enable Link Integrity for a port:
SET PORT {slot.port} LINK_INTEGRITY {enable}
{slot.all} {disable}
The ONline Ethernet 24-Port Module provides bank-level configuration flexibility.
To assign all 24 ports on the module to one of three backplane networks, use the following management command:

SET MODULE {slot} NETWORK {ethernet_1}
To assign a specific connector (bank of 12 ports) to a network, use the following management command:
SET MODULE {slot} CONNECTOR_{1}_NETWORK {ethernet_1}
{2} {ethernet_2} {ethernet_3} {isolated_1} {isolated_2}
When used with a 3Com Fault-Tolerant 10BASE-T Transceiver, remote diagnostics mode allows the 24-Port Module to detect certain unusual failure conditions (including disruption of single wires in the twisted pairs).
Refer to the Fault-Tolerant 10BASE-T Transceiver Installation Guide for more information on this feature.
To enable remote diagnostics mode for a specific port, use the following management command:
SET PORT {slot.port} MODE {remote_diagnostics} {slot.port} {non_remote_diagnostics}
Installing and Operating the Module 3 - 21
{ethernet_2} {ethernet_3} {isolated}

To set the maximum number of data collisions an installed management module allows on a port before it partitions the port, use the following management command:
SET MODULE {slot} AUTOPARTITION_THRESHOLD {31_coll}
You can set the autopartition threshold value to one of the following:
K 63 (default value)
K 255
The proper setting for most network environments is 63 (the default). The 10BASE-T specification suggests a minimum autopartition threshold value of 31, but 31 collisions may cause ports to partition more frequently than necessary.
{63_coll} {127_coll} {255_coll}

After you make configuration changes to a module and ports, you must issue the SAVE MODULE_PORT command to save the new settings.
You can display status information about the 24-Port Module using the following network management commands:
K SHOW PORT
This section describes these commands. Screen output examples are also provided.
For more information, refer to the ONline Ethernet Management Module Installation and Operation Guide.
Installing and Operating the Module 3 - 23

To display information for a module in a specific slot, use the following management command:
SHOW MODULE {slot} {no_verbose}
To display basic information about a 24-Port Module installed in slot 3, specify the NO_VERBOSE command argument, as shown below:
ONline> show module 3 [ENTER]
Slot Module Version Network General Information 03 5124M-TPCL 001 ETHERNET_2 Port (s) are down
To display detailed information about an installed 24-Port Module, specify the verbose command argument, as shown below:
ONline> show module 3 verbose [ENTER]
Slot Module Version Network General Information 03 5124M-TPCL 001 ETHERNET_2 Port (s) are down
Auto-Partition Threshold : 255 COLLISIONS Module Per Port Counters : CONNECTOR 1 Network for Connector 01 : ETHERNET_2 Network for Connector 02 : ETHERNET_2 Dip Network Setting for Connector 01 : ETHERNET_1 Dip Network Setting for Connector 02 : ISOLATED_1
{verbose}

To display information for a specific port, use the following management command:
SHOW PORT {slot.port} {no_verbose} {slot.all} {verbose}
To display basic information for a specific port, specify the NO_VERBOSE command argument. To display basic information for all ports on the 24-Port Module, specify the ALL command argument.
In the following example, SHOW PORT ALL displays basic information for all ports on the 24-Port Module installed in slot 5:
ONline> show port 5.all [ENTER]
Port Display for Module 5124M-TPCL :
Port Mode Status Network General Information 05.01 DISABLED OKAY ISOLATED 05.02 ENABLED OKAY ISOLATED 05.03 ENABLED OKAY ISOLATED 05.04 DISABLED OKAY ISOLATED
Installing and Operating the Module 3 - 25

To display detailed information for all ports on the 24-Port Module, specify the VERBOSE command argument. In the following example, SHOW PORT ALL VERBOSE displays detailed information for all ports on the 24-Port Module installed in slot 17 (only the output for ports 1 and 2 is shown):
ONline> show port 17.all verbose [ENTER]
Port Display for Module 5124M-TPCL :
Port Mode Status Network General Information 17.01 DISABLED OKAY ISOLATED

When you assign all ports on the 24-Port Module to the same network, an installed management module can simultaneously monitor all ports on one connector individually as it monitors the ports on the other connector collectively.
For example, you can use an installed EMM or Distributed Management Module (DMM) to simultaneously:
K Monitor ports 1 through 12 individually
K Sum up statistics for ports 13 through 24 at a single “logical port” (port 13)
Gathering statistics for individual ports on one connector enables network management to provide a detailed statistical view of each port on that connector. Collective statistics gathering for all ports on the other connector ensures you have at least a high-level statistical view of ports on that connector.
An ONline management command lets you switch to monitor the other connector. The following section describes the SET MODULE command.
Installing and Operating the Module 3 - 27

When you select a connector, network management monitors the other connector collectively, reporting statistics for all 12 ports as a single “port.”
To select which 12-port connector you want network management to gather counter statistics for:
SET MODULE {slot} PER_PORT_COUNTERS_CONNECTOR {1} {2}
If you ask for information on a port that is not being monitored individually, network management displays summary statistics and instructions for getting more information on the selected port.

The LEDs on the front panel of the 24-Port Module allow you to monitor the status of 12 ports on each connector. The 24-Port Module has an Activity LED and a Status LED for each connector.
Figure 3-7 shows the location of the LEDs on Model Number 5124M-TPCL.

Figure 3-7. 24-Port Module Faceplate and ONline System
Concentrator (Model Number 5124M-TPCL)
Installing and Operating the Module 3 - 29

Figure 3-8 shows the location of the LEDs on Model Number 5124M-TP.

Figure 3-8. 24-Port Module Faceplate and ONline System
Concentrator (Model Number 5124M-TP)

Table 3-4 describes the LEDs for Model Numbers 5124M-TPCL and 5124M-TP.
Table 3-4. 24-Port Module LED Interpretations
LED Name Color State Indicates
Activity (Ports 1 to 12) (Ports 13 to 24)
Yellow Off No packets are received on the ports on this connector.
On Constant activity on this connector.
Blinking Normal activity on this connector.
Status (Ports 1 to 12) (Ports 13 to 24)
Green On Connector enabled and links OK or Link Integrity disabled.
1 blink Link failure on one or more ports.
2 blinks One or more ports partitioned.
Off Connector disabled.
Installing and Operating the Module 3 - 31

Once you install the 24-Port Module, verify module operation using the front panel of the ONline Controller Module.
The ONline Controller Module is equipped with an LED check button on the front panel. Use the LED check button to:
K Verify LED operation
K Verify network (channel) assignment
The LED check button:
K Causes all LEDs in all modules in the concentrator to light
K Causes each installed module to identify the network to which it is assigned
When you press the LED check button, the Controller Module initiates a test of all modules in the concentrator.
K All LEDs should respond by lighting continuously for approximately 5 seconds.
K Any LED that does not light is defective.
After 5 seconds elapse, the diagnostic continues with a network (channel) check of all installed modules.
K Port Status LEDs on each installed module should blink the number of times corresponding to the network to which that module (or connector) is assigned.

K If the module is in isolated mode, the Port Status LEDs on that module (or connector) do not light.
K Activity LEDs remain on during the network check sequence.
The network check sequence repeats at least three times, and each check sequence lasts for approximately 30 seconds.
Table 3-5 explains the network check codes.
Table 3-5. Network Check Codes
LED State Network Configuration
1 Blink Connector is configured for network 1
2 Blinks Connector is configured for network 2
3 Blinks Connector is configured for network 3
Off Connector is isolated from backplane networks
Installing and Operating the Module 3 - 33



This chapter describes fault conditions and troubleshooting procedures for the ONline Ethernet 24-Port Modules, Model Numbers 5124M-TPCL and 5124M-TP.
This chapter contains the following sections:
K Troubleshooting Using the Port Status LEDs
K Troubleshooting Using the Port Activity LEDs
Troubleshooting 4 - 1
K Technical Assistance

In certain situations, the Port Status and Port Activity LEDs may not light. This section describes troubleshooting using the:
K Port Status LEDs
K Port Activity LEDs
A blinking Port Status indicator signals a problem with a port or a link connected to a port. Once a port detects a problem, you can further analyze the problem by counting the number of blinks. Table 4-1 provides troubleshooting suggestions for each of the blinking sequences.
Table 4-1. Troubleshooting Using the Port Status LEDs
LED State Indication Possible Cause Corrective Action
1 Blink Link Failure Cable not connected.
Connect cable.
Cable defective. Check cables with cable tester. Repair or replace cables.

Table 4-1. Troubleshooting Using the Port Status LEDs (Continued)
LED State Indication Possible Cause Corrective Action
Link Integrity mismatch.
Make sure that both ends of the connection have the same Link Integrity setting.
2 Blinks Port Partitioned
Faulty cable. Check cable with cable tester. Repair or replace cable.
Network overloaded.
Reassign users to another network to balance the load.
Ports disabled. Enable ports.
24-Port Module not powered up.
Check the Controller Module Power LEDs.
Broken LED. Press the LED test button on the Controller Module.
Bad 24-Port Module.
Replace module.
Troubleshooting 4 - 3
1 Blink (continued) · Link Failure (continued) · Off Ports Disabled

Under some conditions a Port Activity LED may not light. Use the troubleshooting suggestions in Table 4-2 to help determine why this has occurred and to isolate the source of the problem.
Table 4-2. Troubleshooting Using the Port Activity LEDs
LED State Possible Cause Corrective Action
Off There is no traffic received from the segments (normal).
None.
Hub power is off. Check the Controller Module Power LEDs.
The Activity LED has burned out.
Press the LED test button on the Controller Module.
A 24-Port Module port is faulty.
Connect the cable to a different port.
The module connection to the backplane is bad.
Re-insert the 24-Port Module. If this fails to correct the problem, try another concentrator slot.
The 24-Port Module is faulty.
Try a different 24-Port Module.
Refer to Appendix B for instructions on contacting Technical Support for your product.

This appendix lists specifications for the ONline Ethernet 24-Port Module (Model Numbers 5124M-TPCL and 5124M-TP).
This appendix contains the following sections:
K Twisted Pair Cable and Connector Specifications
Specifications A - 1

Table A-1 defines general specifications for the 24-Port Module.
Table A-1. 24-Port Module General Specifications
Model Number 5124M-TP, 5124M-TPCL
Ports Per Module 24
Data Rate 10 Mbps (million bits per second)
Data Modulation Differential Manchester
External Connectors Model Number 5124M-TP:
2 Double Stack RJ-45 Connectors
(12 ports per connector)
Model Number 5124M-TPCL:
2 Telco 50-pin Connectors
(12 ports per connector)
Supports UTP, STP, and 120 ohm Cabling Systems
Maximum Number of Stations
Backplane Interface 96-pin edge connector of the ONline System Concentrator or ONcore Switching Hub
2 thumbscrews on the mounting bracket
A - 2 ONline Ethernet 24-Port 10BASE-T Module Installation Guide
Specification Value · Recommended Cable Types · Installation Attachment

Table A-1. 24-Port Module General Specifications (Continued)
ONline Fault-Tolerant Controller Module (Model Numbers 5000M-RCTL, 5000M-RCLS)
A Fault-Tolerant Controller Module is not required if you have a 6-Slot ONline System Concentrator with Integrated Controller (Model Numbers 5006C-HC, 5006C-HC-FT).
A 325 watt power supply and the corresponding 325 watt Power Switching Board is required for the17-Slot ONline System Concentrator
Table A-2 lists power specifications for the 24-Port Module.
Table A-2. 24-Port Module Power Specifications
Backplane Interface Two 96-pin edge connectors, compatible with the ONline System Concentrator and ONcore Switching Hub
Power Requirements 2.0 Amps @ 5 V
Power Consumption 10 watts
Fuse 4.0 Amps Fast Blow
Specifications A - 3
Specification Value · ONline Requirements · Power Specifications Values

Table A-3 lists fuse specifications for the 24-Port Module.
Table A-3. 24-Port Module Fuse Specifications
Fuse Specifications for 24-Port Module
.5 Amp for 12 V FAILSAFE
4 Amp for 5 V
Table A-4 lists environmental specifications for the 24-Port Module.
Table A-4. 24-Port Module Environmental Specifications
Operating Temperature 0° to 50° C (32° to 122° F)
Storage Temperature -30° to 65° C (-22° to 149° F)
Humidity 5% to 95%, non-condensing
A - 4 ONline Ethernet 24-Port 10BASE-T Module Installation Guide
Environmental Specifications Values · BTUs/hour 30

Table A-5 lists mechanical specifications for the 24-Port Module.
Table A-5. 24-Port Module Mechanical Specifications
Mechanical Specifications 5124M-TPCL Values 5124M-TP Values
Dimensions 2.54 cm W x 27.31 cm L x 21.6 cm H (1.0" x 10.75" x 8.5")
5.08 cm W x 27.31 cm L x 21.6 cm H (2.0" x 10.75" x 8.5")
Weight 0.57 kg (1.25 lb.) 0.68 kg (1.5 lb.)
You can use many types of cables and connectors to link a 24-Port 10BASE-T Module to your network. These cables and connectors are explained in the following sections. Use this information to ensure that the cables and connecting hardware meet requirements. For proper operation, use only approved cables when you install all equipment.
This section describes:
K Twisted Pair Cable Specifications
K Twisted Pair Connector Specifications
K RJ-45 Connector Pinouts
K 50-Pin Connector Pinouts
K Connecting Twisted Pair Cables
Specifications A - 5

The cables that are supported must meet the following specifications:
K 22, 24, or 26 gauge twisted pair cable
K 80 to 150 ohm impedance
K Minimum of 2 pairs
A pair is usually a solid color wire twisted with a striped wire of the same color.
Table A-6 lists the specifications for IBM cable types 1, 2, 6, and 9. These cable types are IEEE 802.5 compliant and are ETL (ETL Testing Laboratories) verified.
Table A-6. IBM Twisted Pair Cable Specifications
IBM Type No. of
Pairs AWG Shielding Nominal Impedance
2 22 (solid bare copper)
Data pairs individually foil shielded plus 65% tinned copper braid
6 (data 2) (voice 4)
22 (solid bare copper)
Data pairs individually foil shielded plus 65% tinned copper braid. Voice pairs non-shielded*
Data 150 ohms Voice 105 ohms
2 26 (7x34 bare copper)
Overall foil shielded pairs plus 65% tinned copper braid
9 (plenum) 2 26 (7x34 bare copper)
Individually foil shielded plus 65% tinned copper braid
A - 6 ONline Ethernet 24-Port 10BASE-T Module Installation Guide

*Voice pairs in the IBM Type 2 cable cannot be used for Token Ring data transmission.
The IEEE 802.3 10BASE-T standard for RJ-45 pinouts must be used, as described below. 10BASE-T uses only 2 of 4 pairs of wire: pins 1 & 2 and pins 3 & 6. If the pairs are not configured this way, the connection will not work properly.
Level 3 or higher cable should have the following pin pairings:
K Pair 1 is pins 4 and 5 (not used)
K Pair 2 is pins 3 and 6
K Pair 3 is pins 1 and 2
K Pair 4 is pins 7 and 8 (not used)
Refer to Figure A-1 for an example of the recommended TIA-568A standard pinouts for this connector and cable.
Figure A-1 shows RJ-45 connector pin assignments for the 24-Port Module, Model Number 5124M-TP. This model uses MDI-X (crossed-over) wiring and only uses:
K Pins 1 and 2 (station transmit) - 5124M-TP receive
K Pins 3 and 6 (station receive) - 5124M-TP transmit
Specifications A - 7


Figure A-1. 24-Port Module RJ-45 Connector Pinouts
Figure A-2 provides examples of a 50-pin cable (male) connector and a 50-pin (female) connector on the 24-Port Module.
A - 8 ONline Ethernet 24-Port 10BASE-T Module Installation Guide


Figure A-2. 50-Pin Male and Female Connectors
Table A-7 (next page) lists the receive and transmit pairs, pinouts, and port assignments for a 50-pin cable.
Specifications A - 9

Table A-7. 50-Pin Cable Pinouts and Port Assignments
Port 1 26 RX, + TX, + (1) Port 7 38 RX, + TX, + (1)
Port 1 1 RX, - TX, - (2) Port 7 13 RX, - TX, - (2)
Port 1 27 TX, + RX, + (3) Port 7 39 TX, + RX, + (3)
Port 1 2 TX, - RX, - (6) Port 7 14 TX, - RX, - (6)
Port 2 28 RX, + TX, + (1) Port 8 40 RX, + TX, + (1)
Port 2 3 RX, - TX, - (2) Port 8 15 RX, - TX, - (2)
Port 2 29 TX, + RX, + (3) Port 8 41 TX, + RX, + (3)
Port 2 4 TX, - RX, - (6) Port 8 16 TX, - RX, - (6)
Port 3 30 RX, + TX, + (1) Port 9 42 RX, + TX, + (1)
Port 3 5 RX, - TX, - (2) Port 9 17 RX, - TX, - (2)
Port 3 31 TX, + RX, + (3) Port 9 43 TX, + RX, + (3)
Port 3 6 TX, - RX, - (6) Port 9 18 TX, - RX, - (6)
Port 4 32 RX, + TX, + (1) Port
Port 4 7 RX, - TX, - (2) Port
Port 4 33 TX, + RX, + (3) Port
Port 4 8 TX, - RX, - (6) Port
A - 10 ONline Ethernet 24-Port 10BASE-T Module Installation Guide

Table A-7. 50-Pin Cable Pinouts and Port Assignments (Continued)
Port 5 34 RX, + TX, + (1) Port
Port 5 9 RX, - TX, - (2) Port
Port 5 35 TX, + RX, + (3) Port
Port 5 10 TX, - RX, - (6) Port
Port 6 36 RX, + TX, + (1) Port
Port 6 11 RX, - TX, - (2) Port
Port 6 37 TX, + RX, + (3) Port
Port 6 12 TX, - RX, - (6) Port
50 Not Used Not Used
25 Not Used Not Used
Specifications A - 11

Follow these steps to connect twisted pair cables:
Refer to the ONline System Concentrator Installation and Operation Guide for more information about the ONline System Concentrator connections.
A - 12 ONline Ethernet 24-Port 10BASE-T Module Installation Guide

3Com provides easy access to technical support information through a variety of services. This appendix describes the following services:
K On-line Technical Support
K Support from Your Network Supplier
K Support from 3Com
K Returning Products for Repair
K Accessing the 3Com MIB
K 3Com Technical Publications
3Com offers worldwide product support through the following on-line systems:
K Email Technical Service
K World Wide Web Site
Technical Support B - 1

You can contact the Integrated Systems Division (formerly Chipcom) on the Internet for technical support using the e-mail address techsupp@chipcom.com.
You can access the latest networking information on the 3Com World Wide Web site by entering our URL into your Internet browser:
This service features news and information about 3Com products, customer service and support, the 3Com latest news releases, selected articles from 3TECH™, the 3Com award-winning technical journal, and more.
You can contact the Integrated Systems Division on the World Wide Web by entering our URL into your Internet browser:
There are links between both WWW pages to view information from all 3Com divisions.
If additional assistance is required, contact your network supplier. Many suppliers are authorized 3Com service partners who are qualified to provide a variety of services, including network planning, installation, hardware maintenance, application training, and support services.
B - 2 ONline Ethernet 24-Port 10BASE-T Module Installation Guide

When you contact your network supplier for assistance, have the following information ready:
K Diagnostic error messages
K A list of system hardware and software, including revision levels
K Details about recent configuration changes, if applicable
If you are unable to contact your network supplier, see the following section on how to contact 3Com.
If you are unable to receive support from your network supplier, technical support contracts are available from 3Com.
For direct access to customer service for Integrated Systems Division products in:
K U.S.A. and Canada - call (800) 724-2447
K Asia Pacific - call (508) 787-5151
K Europe - refer to the table below
K For European countries not listed, call 31 30 60 299 00
Country Telephone Number Country Telephone Number
Belgium 0800 71429 Netherlands 06 0227788
Denmark 800 17309 Norway 800 11376
Finland 0800 113153 Spain 900 983125
France 05 917959 Sweden 020 795482
Germany 0130 821502 U.K. 0800 966197
Ireland 1 800 553117 U.S. 800 876-3266
Technical Support B - 3
Italy 1678 79489

For access to customer service for all 3Com products, call (800) 876-3266.
You can also contact the Integrated Systems Division (ISD) on the Internet by using the e-mail address techsupp@chipcom.com.
A product sent directly to 3Com for repair must first be assigned a Return Materials Authorization (RMA) number. A product sent to 3Com without an RMA number will be returned to the sender unopened, at the sender’s expense.
To obtain an RMA number for Integrated Systems Division products (formerly Chipcom), use the following numbers.
Country Telephone Number Fax Number
U.S. and Canada (800) 724-2447 (508) 787-3400
Europe (44) (1442) 275860 No Fax
Asia Pacific (508) 787-5296 (508) 787-3400
The 3Com Management Information Base (MIB) for the Integrated Systems Division describes commands that enable you to manage 3Com SNMP-based products. The MIB is available over the Internet on an anonymous FTP server. Updates to these MIBs are released as new 3Com products are introduced.
To access Internet versions:
B - 4 ONline Ethernet 24-Port 10BASE-T Module Installation Guide

K To pause the display, press [CTRL-S].
K To continue the display, press [CTRL-Q].
If you have comments or questions on 3Com Integrated Systems Division Technical Publications documents, please contact the Technical Publications group by FAX (508) 229-1551.
Technical Support B - 5




Saving, 3-23 Showing, 3-23
Fault-Tolerant Controller Module, A-3 FCC notice, ii Features, 1-1 Fiber Link Distances, 2-5 Fiber Module Configurations, 2-10 Front Panel
Unshielded Twisted Pair, 2-13 Network Check Codes, 3-33 Network Selection
Monitoring, 3-29 Front Panel Indicators
Per Connector, 3-21 network supplier support, B-2
Activity LEDs, 3-29, 3-31 Status Indicators, 3-29 Status LEDs, 3-31
G
ONline Network Management Module, 3-19 ONline System Concentrator
Hot Swap Capabilities, 3-10 on-line technical services, B-1
General Specifications, A-5
Patch Panels, 2-14 Port Redundancy, 3-19
180 Connector, 3-11 90 Connectors, 3-15 Hot Swap Capabilities, 3-10 Installing The Module, 3-11 Quick Installation Chart, 3-2 Installing the 24-Port Module, 3-10 Installing the Module, 3-2
Switchover Conditions, 2-17 Ports
Configuring Using Network Management,
Redundancy, 2-17 Redundant Links, 2-16 returning products for repair, B-4
LAN Product Equivalent Distances, 2-6 LED and Network Verification, 3-32 Link Integrity
Management, 3-20 Description, 3-20
Serial Configuration, 2-9 Showing Module Configurations, 3-23 SNMP Commands, B-4 Specifications
MIB, B-4 Module Configurations
Environmental, A-4 Fuses, A-3

Power, A-3 Star Configuration, 2-8 Star Topology, 2-3 Status LEDs
Troubleshooting Using, 4-2
technical support, B-1 Troubleshooting
Port Activity LEDs, 4-4 Using Port Status LEDs, 4-2 Twisted Pair
Cables, A-6, A-12 Connectors, A-7 Twisted Pair Cables
Connecting, A-12 Twisted Pair Configuration
Redundant Links, 2-16
Unpacking Procedures, 3-4 Unshielded Twisted Pair, 2-12
VDE compliance, ii
Index 3


Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.