SAFETY INFORMATION
Please read this manual before installing and using appliance.
Models: VCBV30MN, VCBV30MP - 30,000 Btu/Hr Manual VCBV20MN, VCBV20MP - 20,000 Btu/Hr Manual VCBV10MN, VCBV10MP - 10,000 Btu/Hr Manual
Models: VCPV30MN, VCPV30MP - 30,000 Btu/Hr Manual VCPV18MN, VCPV18MP - 18,000 Btu/Hr Manual VCPV10MN, VCPV10MP - 10,000 Btu/Hr Manual VCPV06MN, VCPV06MP - 6,000 Btu/Hr Manual
Installer: Leave this manual with the consumer. Consumer: Retain this manual for future reference.

VERMONT Castings VERMONT Castings
20003769 8/02 Rev. 1
Blue Flame Heaters · VERMONT Castings · Plaque Heaters


DO NOT USE THIS HEATER AT AN ELEVATION ABOVE 4,500 FEET

Fig. 1 Product identification.

VCBV30 / VCBV20 / VCBV10 VCPV30 / VCPV18 / VCPV10 / VCPV06
This heater has a pilot with an Oxygen Depletion Sensor shutt-off system (ODS). The ODS pilot is a required feature for vent-free heaters. The ODS pilot shuts off the heater if the normal air oxygen content is reduced to 18%.
Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of the National Fuel Gas Code ANSI Z223.2, also know as NFPA54.
This heater has a piezo ignitor. This system requires no matches, batteries or other sources to light the heater.
Available from: American National National Fire Protection Standards Institute, Inc. Association, Inc. 1430 Broadway Batterymarch Park New York, NY 10018 Quincy, MA 02269

For proper operation of the unit, provide fresh air opening(s) to the room. Follow the National Fuel Code NFPA54/ANSI Z223.1, for required size of combustion and ventilation openings.
WARNING:
This heater must have fresh air for proper operation. If not, poor fuel combustion could result. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.
Verify the type of gas supply to be used, either natural gas or LP (Propane), and make sure the marking on the appliance rating plate agrees with that of the supply gas. The rating plate is located on the side of the heater, which indicates the type of gas the heater is orificed for.
Modern construction standards have resulted in homes that are highly energy-efficient and that allow little heat loss. Your home needs to breathe, however, and all fuel-burning appliances need fresh air to function properly and safely. Exhaust fans, clothes dryers, fireplaces and other fuel burning appliances all use the air inside the building. If the available fresh air supply is insufficient to meet the demands of these appliances, problems can result.
Before installing the heater, make sure you have these items:
Any space within a home can be classified in these categories:
Unusually tight construction: The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air. Unusually tight construction is defined as construction where:
* An installer supplied design-certified manual shut-off valve with 1/8” NPT tap connection.
Walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one perm or less with openings gasketed or sealed and;
This heater is designed to be mounted on a wall or on the floor.
Caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall/ceiling joints, between wall panels, at penetrations for plumbing, electrical and gas lines, and at other openings.
Unconfined space: An unconfined space whose volume is not less than 50 cubic feet for each 1,000 Btu/Hr of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed, through openings not furnished with doors are consid- ered a part of the unconfined space.
* Models VCPV06M(N,P) permitted for bathroom installations.
Confined space: A confined space whose volume is less than 50 cubic feet for each 1,000 Btu/Hr of the aggregate input rating of all appliances in that space.

This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes.
*Aftermarket: Completion of sale, not for purpose of resale from manufacturer.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
Fig. 3 Use paper template supplied to mark location of
mounting holes. Be sure template is level.
Min.
When mounting heater to hollow walls (wall areas between studs) or solid walls (concrete or masonry) it may be necessary to use wall anchors.
Min.
Min.
A = 21¹⁄₄" (330 mm) @ 30,000 Btu/ hr Model 13¹¹⁄₁₆" (347 mm) @ 18,000/20,000 Btu/ hr Model 9⁷⁄₈" (251 mm) @ 10,000 Btu/ hr Model 9⁷⁄₈" (251 mm) @ 6,000 Btu/ hr Model
Fig. 2 Minimum clearances to floor, adjacent walls and
ceiling.


Before connecting the appliance, turn off all gas appli- ances. Close the main gas valve at the gas meter or Lp tank. Make certain there is good ventilation where the installation will be made. Installation should comply with all applicable building codes and ANSI Z223.1, latest edition. Use LP gas resistant pipe compound to seal threaded joints.
An installer supplied, design certified gas pressure regulator must be installed to bring the gas supply pressure down to 14” w.c.
Install sediment trap in supply line as shown in Figure 6. Locate sediment trap where it is within reach for


Natural Gas (4” w.c. to 10.5” w.c. Pressure) LP Gases (11.5” w.c. to 14.0” w.c. Pressure) RH103
Fig. 6 Gas line connection.
Fig. 5 Optional wall mounting screws for floor installation.

cleaning. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap prevents moisture and contaminants from going into the heater controls. If the sediment trap is not installed or is installed wrong, the heater may not operate properly.
Test for gas leaks with a mild soap and water solution. Apply water/soap solution with brush only - do not over apply. NEVER test with an open flame.
The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of the system at test pressures in excess of 1/2 psi.
The appliance must be isolated from the gas supply piping system by closing the individual manual shut-off valve (Fig. 7) during any pressure testing of the gas supply system at test pressures equal to or less than 1/2 psi.
Fig. 7 Manual shut-off valve location.

. Release the downward pressure on the knob while continuing to turn until the knob locks at the desired setting position. Do not operate between the locked positions.
A. BEFORE LIGHTING smell all around the appliance
area for gas. Be sure to smell next to floor because some gas is heavier than air and will settle on the floor.
OFF
PILOT/IGN
PILOT/IGN
IF YOU SMELL GAS: 1. Do not try to light any appliance.
HIGH
LOW
MED
HIGH
VCBV10 & VCPV10 Only
Fig. 8 Control knob.
B. Use only your hand to push in or turn the gas valve
control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.
Turn control knob clockwise to the OFF position.
Turning Burner Only Off (Pilot stays lit)
Turn control knob clockwise to the PILOT position.
C. Do not use this appliance if any part has been under
water. Immediately call a qualified service technician to inspect the appliance and to replace any part of this control system and any gas control which has been under water.
1. Read the safety information on previous page. 2. Make sure manual shut-off valve is fully open. 3. Push in gas control knob slightly and turn clockwise to the OFF position. 4. WAIT 5 MINUTES TO CLEAR OUT ANY GAS. If you then smell gas, STOP! Follow A in the safety information. If you do not smell gas, go to next step. 5. Push in gas control knob slightly and turn counter- clockwise to ‘PILOT/IGN” and depress for five (5) seconds. This will allow air to bleed from the gas system. 6. Release control knob pressure and turn clockwise to “OFF”.
Turning Heater Off


Each time you light your heater check that the pilot flame and burner flame patterns are as shown in Figures 9, 10 and 11. If flame patterns are incorrect, turn the heater off. Contact your dealer or a qualified gas technician for assistance. Do not operate the heater until the pilot flame is correct.
Fig. 10 Correct burner flame pattern for the VCBV blue flame
burner.


Fig. 11 Correct burner flame pattern for the VCPV plaque heater.
Fig. 9 Proper pilot flame.


Dust, lint, cobwebs or debris may affect heater perfor- mance. The heater draws air into it during normal operation and in the process dust, lint or debris may be drawn in also. It is important to keep the burner , gas control and combustion and circulating air passage- ways clean. Inspect or have these areas inspected annually at the beginning of the heating season by a qualified service person. Depending on the surround- ings, the room heater may require frequent cleaning due to excessive lint or debris.
Clean the exterior with soft bristle brush, vacuum cleaner or pressurized air. Never use a wooden tooth- pick as it may break off and clog the ODS pilot or main burner port.
Use a flashlight to inspect the main burner inlet to ensure it is not blocked. If obstruction can be seen, use a metal wire coat hanger that has been straightened out.
Before cleaning ensure the gas supply is off and the gas control knob is in the OFF position. Make sure the heater is cool.
Use a vacuum cleaner to clean the primary air openings to the main burner(s).
In order to clean ODS pilot orifice, use pressurized air to blow dust out. Sometimes blowing air backwards through the pilot will get rid of the accumulated dirt. If that does not work, blow out any dust through primary air openings of pilot assemblies (Daemyeong has two openings; one beneath the bimetal strip and the second one opposite from bimetal strip. Use the one wide open, do not try to lift the bimetal strip.)
and Unit Casings
Use a vacuum cleaner or pressurized air to clean the combustion and circulating air passageways and dampened cloth to clean the cabinet/casing.
Troubleshooting, continued


The Vermont Castings Majestic Products Company reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
Item / Model Number VCBV10MN/MP VCBV20MN/MP VCBV30MN/MP
1. Guard Assembly RBW33XX0 RBW30XX0 RBW26XX0 2. Glass Panel RBC02XC0 RBC02XB0 RBC02XA0 3. Holder Glass RBP63PC0 RBP63PB0 RBP63XPA0 4. Reflector RBP71PX0 RBP70PX0 RBW23XX0 5. Cover Heat - Upper -- RBP61XB0 RBP61XA0 6a. Pressure Regulator (Daemyeong Korea) - Natural DR40M2PN DR40M2KN DR40M3KN 6b. Pressure Regulator (Daemyeong Korea) - LP DR40M2PL DR40M2KL DR40M3KL 7. Nozzle Holder RBM06XX0 RBM06XX0 RBM06XX0 8a. ODS Pilot Assembly (Daemyeong Korea) - Natural DS98N02 DS98N02 DS98N02 8b. ODS Pilot Assembly (Daemyeong Korea) - LP DS98PL02 DS98PL02 DS98PL02 9. Fix Nut - Nozzle Holder RBM08XX0 RBM08XX0 RBM08XX0 10a. Main Nozzle - Natural RBM07XE RBM07XA RBM07XC 10b. Main Nozzle - LP RBM07F0 RBM07B0 RBM07E0 11. Bracket - Valve RBP59XX0 RBP59XX0 RBP59XX0 12a. Gas Control (Daemyeong Korea) - Natural DMV101PA DMV100PA DMV100PC 12b. Gas Control (Daemyeong Korea) - LP DMV101PB DMV100PB DMV100PD 13. Tubing Outlet Assembly RBT28XX0 RBT22XX0 RBT16XX0

Item / Model Number VCBV10MN/MP VCBV20MN/MP VCBV30MN/MP
14. Tubing ODS Assembly RBT27XX0 RBT21XX0 RBT15XX0 15. Tubing Inlet Assembly RBT26XX0 RBT20XX0 RBT14XX0 16. Leg - Front RBI06XX0 RBI06XX0 RBI06XX0 17. Front Panel RBP69PA0 RBP66PA0 RBW22XA0 18. Burner Assembly RBW13XX0 RBW09XX0 RBW08XX0 19a. Burner Support - Left RBP06XA RBP06XA- RBP06XA 19b. Burner Support - Right RBP06XB0 RBP06B0 RBP06B0 20. Frame Body Assembly RBW31PB0 RBW31PB0 RBW20PB0 21. Leg - Rear RB105XX0 RB105XX0 RB108XX0 22. Knob - Valve RB104XX0 RB104XX0 RBI04XX0 23. Shield RBP100 RBP101 RBP105 24. Rear Radiant Shield -- 10003986 10003984


Vermont Castings, Majestic Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
Item / Model Number VCPV06MN/MP VCPV10MN/MP VCPV18MN/MP VCPV30MN/MP
1. Cover Heat - Lower RCP10XC0 RCP10XC0 RCP10XB0 RCP10XA0 2. Guard Assembly RBM33XX0 RBW33XX0 RBW30XX0 RBW26XX0 3. Reflector 0RH0002 RCP34PX0 RCP33PX0 RCW10XX0 4. Cover Heat - Upper -- - RBP61XA0 RBP61XA0 5. Leg Front RB106XX0 RBI06XX0 RBI06XX0 RBI06XX0 6. Front Panel RBP69PA0 RBP69PA0 RBP66PA0 RBP57PA0 7. Burner Body Assembly 2RH0006 RCW13XX0 RCW12XX0 RCW11XX0 8. Ceramic Plate 3D0310 RCC03XX0 RCC01XA0 RCC01XA0 9. Frame Body Assembly RBW32PB0 RBW32PB0 RBW27PB0 RBW20PB0 10. Knob - Valve RB104XX0 RBI04XX0 RBI04XX0 RBI04XX0 11. Leg - Rear RB105XX0 RBI05XX0 RBI05XX0 RBI05XX0 12. Link - Valve RCP13XE0 RCP13XE0 RCP13XD0 RCP13XC0 13. Fix Pin - Link RCS01XX0 RCS01XX0 RCS01XX0 RSC01XX0 14a. Gas Control (Daemyeong Korea) DMV100PHB DMV200PA DMV300PA DMV300PA 15. Tubing Inlet Assembly RCT65XX0 RCT65XX0 RCT51XX0 RCT37XX0 16. Tubing Outlet - A Assembly 3RH0005 RCT66XX0 RCT52XX0 RCT38XX0 17. Tubing Outlet - B Assembly -- RCT67XX0 RCT53XX0 RCT09XX0 18. Tubing Outlet - BL Assembly -- -- -- RCT40XX0 19. Tubing Outlet - BR Assembly -- -- -- RCT41XX0

Item / Model Number VCPV06MN/MP VCPV10MN/MP VCPV18MN/MP VCPV30MN/MP 20. Tubing Outlet - C Assembly -- -- RCT54XX0 RCT12XX0 21. Tubing Outlet - CL Assembly -- -- -- RCT13XX0 22. Tubing Outlet - CR Assembly -- -- RCT14XX0 -- 23. Manifold - “C” -- -- RCD02XX0 -- 24. Tubing ODS Assembly RCT63XX0 RCT63XX0 RCT59 RCT45 25a. ODS Pilot Assembly (Daemyeong Korea) - Natural DS99PN03 DS98PN01 DS98PN01 DS98PN01 25b. ODS Pilot Assembly (Daemyeong Korea) - LP DS98PL01B DS98PL01 DS98PL01 DS98PL01 26a. Main Nozzle - Natural RCM02XG0 RCM02XD0 RCM02XB0 RCM02XA0 26b. Main Nozzle - LP RCM02XB0 RCM02XE0 RCM02XC0 RCM02XB0 27. Connector - “B” RCM01XX0 28a. Pressure Regulator (Daemyeong Korea) - Natural DR40M3PN DR40M2PN DR40M3PN DR40M5PN 28b. Pressure Regulator (Daemyeong Korea) - LP DR40M3PL DR40M2PL DR40M3PL DR40M5PL 29. Rear Radiant Heat Shield -- -- 10003986 10003985 30. Shield RBP84 RBP84 RBP101 RBP104
The following accessories are available from your local Vermont Castings dealer. Each accessory comes with a separate installation instruction. Be sure to read each instruction thoroughly before installing.
Manual Fan Kit FMA-F
Thermostat Fan Kit FMA-FT
Contact Vermont Castings Majestic, Products with questions concerning prices and policies covering replacement parts. Parts may be ordered through you Vermont Castings distributor or dealer.
Model and serial numbers are listed on the rating plate (located on right side of heater). Record your model and serial numbers here for future reference.
You will need the following information when ordering replacemet parts:
Should you need additional information beyond what your dealer can furnish, contact:
Vermont Castings, Majestic Products 410 Admiral Blvd. Mississauga, Ontario Canada L5T 2N6
Description Model Number · Model # Serial #

The Vermont Castings Majestic Products Company warrants this product to be free form defects in materi- als and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accor- dance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EX- CLUDES ANY AND ALL OTHER EXPRESSED WAR- RANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRAN- TIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS FROM THE DATE OF FIRST PURCHASE; AND THE VER- MONT CASTINGS MAJESTIC PRODUCTS COMPANY SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a Vermont Castings authorized dealer/distributor. Warranty part(s) MUST be obtained through authorized dealers of this product and/or Vermont Castings Majes- tic Products who will provide original factory replace- ment parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limita- tion on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diag- nostic cost, labor, transportation and any and all such other costs related to repairing defective heater will be the responsibility of the owner.
Always specify model and serial number when commu- nicating with the factory.
© Vermont Castings, Majestic Products
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| When control knob is pressed in and turned counterclockwise to ignition, there is no spark at ODS pilot. | 1. Ignitor electrode positioned wrong. 2. Ignitor electrode broken. 3. Ignitor cable pinched or broken. 4. Ignitor cable not connected to ignitor electrode. | 1. Replace ignitor electrode. 2. Replace electrode. 3. Free ignitor cable, if damaged replace. 4. Connect cable to electrode. | p.10 |
| When control knob is pressed in and turned counterclockwise to ignition/pilot position, there is spark but no ignition. | 1. Gas supply turned off. 2. Control knob not in pilot position. 3. Control knob not pressed in while in pilot position. 4. ODS pilot is clogged. 5. Air in gas lines. | 1. Turn gas supply on. 2. Turn control knob to pilot position. 3. Press in control while in pilot position. 4. Call a qualified service technician. 5. Purge gas lines and repeat ignition operation. | p.10 |
| ODS pilot lights but flame goes out when control knob is released. | 1. Control knob not pressed long enough. 2. Safety interlock is triggered. 3. Pilot flame not touching the thermo- couple. Problem could be result of one or both of the following: • Partially clogged ODS pilot orifice. • Low gas pressure. 4. Thermocouple damaged. 5. Thermocouple connection loose at gas control valve. 6. Gas control valve damaged. | 1. After ODS pilot lights, keep control knob pressed in approximately 30 seconds. 2. Wait one minute, repeat ignition operation. 3. Contact your gas company, gas supplier or qualified service technician. 4. Replace thermocouple. 5. Hand tight until snug then tighten 1/4 turn with a wrench. 6. Replace gas control. | p.10 |
| Burner does not light after ODS pilot is lit. | 1. Burner orifice clogged. 2. Gas supply pressure is very low. | 1. Clean burner orifice. 2. Contact gas supplier. | p.10 |
| Delayed ignition. | 1. Main burner carry over ports clogged. 2. Gas supply pressure is very low. | 1. Clean main burner ports. 2. Contact gas supplier. | p.10 |
| Burner backfiring during operation. | 1. Burner orifice is clogged. 2. Burner ports damaged. | 1. Clean burner orifice. 2. Replace burner. | p.10 |
| Yellow flames during burner operation. (VCBV) | 1. Not enough air. | 1. Check air passageways and burner for dirt and debris (Refer to Maintenance section) | p.10 |
| Burner plaque(s) does not glow. (VCPV) | 1. Plaque(s) is damaged. 2. Inlet gas pressure too low. 3. Control knob set between locked positions. | 1. Replace burner. 2. Contact local gas supplier. 3. Turn control knob until it locks at desired setting. | p.10 |
| Slight smoke and odor during initial operation. | 1. Residues from manufacturing processes. | 1. Will stop after a few hours of operation. | p.10 |
| Heater produces a whistling noise when burner is lit. | 1. Air passageways blocked. 2. Air in gas line. | 1. Check minimum installation clearances and air passageways for debris. 2. Operate burner until the air is completely purged. | p.10 |
| Heater produces a clicking noise just after burner is lit or turned off. | 1. Metal expanding and contracting. | 1. This is common with heaters. If noise is excessive, contact a qualified service technician. | p.11 |
| Gas odor even when control knob is in OFF position. | 1. Gas leaks. Refer to front page Warnings. 2. Gas control defective. | 1. Locate and correct leaks immedi- ately. 2. Replace gas control. | p.11 |
| Gas odor during combustion. | 1. Foreign matter in gas or on burner ports. 2. Heater burning vapors form paint, impurities in air. 3. Gas leaks, refer to front page Warnings. | 1. Check gas passage way and burner. 2. Ventilate room, stop storing and using odor causing products near heater. 3. Locate and correct leaks immedi- ately. | p.11 |
| Heater shuts off on ODS | 1. Not enough fresh air is available. 2. Low gas pressure. 3. ODS pilot partially clogged. | 1. Open window. 2. Contact gas supplier. 3. Clean the pilot. | p.11 |