INSTALLER/CONSUMERp.1SAFETY INFORMATIONp.1PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCEp.1Rear Vented Direct Vent Gas Fireplace Model:p.1DVR33p.1WHAT TO DO IF YOU SMELL GAS:p.1Homeowner's Installation andp.1Operating Manualp.1Vermont Castings, Majestic Productsp.1INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNERp.1Installation and Operating Instructionsp.3Locating Your Fireplacep.3E A Bp.3Y Bp.3LU584-Rp.3Clearance to Combustiblesp.5F G H Ip.5Mantelsp.5Mantel Mantel Leg from Side of Ref. Leg Depth Ref. Combustion Openingp.5Hearthp.5CFM174p.5Framing and Finishingp.6Final Finishingp.6DVR33 CERTIFIED TOp.6ANSI Z21.88-2002 / CSA 2.33-2002p.6High Elevationsp.6FP1023p.6Alternate Switch Locationp.7EB-1 Electrical Boxp.8FP580p.8Electronic Gas Control Valvep.9PILOTp.9HONEYWELL IGNITION MODULEp.9MV MV/VP PV GRD 24V SENSE SPARKp.9GREENp.9ORANGEp.9REDp.9LOp.9HIp.9NOVA SIT 822 VALVEp.9BLUEp.9WHITEp.9POWER CORD W/FEMALE SPADEp.924 VAC HOTp.9120 VAC RTNp.9BLACKp.9OFFp.9YELLOWp.924 VAC RETp.9120 VAC HOTp.940VA TRANSFORMERp.9WALL SWITCHp.9BLACK WHITEp.9General Venting Informationp.9Twist Lock Pipesp.12Rear Wall Vent Installationp.12Step 1p.12TWL100p.12Rear Wall Vent Applicationp.12Step 2p.12Step 4p.13Step 5p.13How To Use the Vent Graphp.14Vertical Sidewall Applicationp.14CFM102p.14Vertical Sidewall Installationp.16Step 3p.16Step 6p.16Step 7p.17Below Grade Installationp.17Vertical Through-the-Roof Applicationsp.18Vertical Through-the-Roof Installationp.19DVR33 Bracket Restricter Installationp.20Twist Lock Venting Componentsp.21Crimped End Venting Componentsp.22Operating Instructionsp.23Glass Informationp.23Louvre Removalp.23FP1191p.23Glass Cleaningp.23
Page 1 of the Vermont Casting DVR33 user manual — INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER
Page 1 · click to enlarge
Page 1

INSTALLER/CONSUMER

SAFETY INFORMATION

PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE

Rear Vented Direct Vent Gas Fireplace Model:

DVR33

FOR YOUR SAFETY Installation and service must be performed by a qualified installer, service agency or the gas supplier.

WHAT TO DO IF YOU SMELL GAS:

  • Do not try to light any appliance.
  • Do not touch any electric switch; do not use any phone in your building.
  • Immediately call your gas supplier from your neighbor's phone. Follow the gas suppliers instructions.
  • If you cannot reach your gas supplier call the fire department.

Homeowner's Installation and

Operating Manual

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.

Vermont Casting DVR33 — Homeowner's Installation and diagram (page 1)
Fig. 1 · Homeowner's Installation and
Vermont Casting DVR33 — Homeowner's Installation and diagram (page 1)
Fig. 2 · Homeowner's Installation and

Vermont Castings, Majestic Products

  • 410 Admiral Blvd.
  • Mississauga, Ontario, Canada L5T 2N6
  • 905-670-7777 <a href="http://www.majesticproducts.com" rel="nofollow noopener" target="_blank">www.majesticproducts.com</a>
  • <a href="http://www.vermontcastings.com" rel="nofollow noopener" target="_blank">www.vermontcastings.com</a>

INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER

10004920 01/03 Rev.0

10004920

Page 2 of the Vermont Casting DVR33 user manual — INSTALLER/CONSUMER
Page 2 · click to enlarge
Page 2
Page 2 of the Vermont Casting DVR33 user manual — INSTALLER/CONSUMER
Page 3 of the Vermont Casting DVR33 user manual — Locating Your Fireplace
Page 3 · click to enlarge
Page 3

Installation and Operating Instructions

This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA- B149.1 Installation codes for Gas Burning Appliances and Equipment. If the unit is being installed in a mobile home, the installation should comply with the current CAN/CSA Z 240.4 code. For U.S.A. Installations follow local codes and/or the current National Fuel Gas Code. ANSI Z223.1. FOR SAFE INSTALLATION AND OPERATION PLEASE NOTE THE FOLLOWING: 1. This fireplace gives off high temperatures and should be located out of high traffic areas and away from furniture and draperies. 2. Children and adults should be alerted to the hazards of the high surface temperatures of this fireplace, and should stay away to avoid burns or ignition of clothing. 3. Children should be carefully supervised when in the same room as your fireplace. 4. Under no circumstances should this fireplace be modified. Parts removed for servicing should be replaced prior to operating this fireplace again. 5. Installation and any repairs to this fireplace must be performed by a qualified installer, service agency or gas supplier. A professional service person should be contacted to inspect this fireplace annually. Make it a practice to have all of your gas fireplaces checked annually. More frequent cleaning may be required due to excess lint and dust from carpeting, bedding material, etc. 6. Control compartments, burners and air passages in this fireplace should be kept clean and free of dust and lint. Make sure the gas valve and pilot light are turned off before you attempt to clean this fireplace. 7. The venting system (chimney) of this fireplace should be checked at least once a year and if needed your venting system should be cleaned. 8. Keep the area around your fireplace clear of com- bustible materials, gasoline and other flammable vapor and liquids. This fireplace should not be used as a drying rack for clothing, nor should Christmas stocking or decorations be hung in the area of it. 9. Under no circumstances should any solid fuels (wood, coal, paper or cardboard etc.) be used in this fireplace. 10. The flow of combustion and ventilation air must not be obstructed in any way. 11. When fireplace is installed directly on carpeting, vinyl tile or any combustible material other than wood, this fireplace must be installed on a metal or wood panel extending the full width and depth of the fireplace. 12. This fireplace requires adequate ventilation and combustion air to operate properly. 13. This fireplace must not be connected to a chimney flue serving a separate solid fuel burning fireplace. 14. When the fireplace is not in use it is recommended that the gas valve be left in the OFF position.

PROPOSITION 65 WARNING Fuels used in gas, wood-burning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm.

California Health & Safety Code Sec. 25249.6

This appliance may be installed in an aftermarket,

permanently located, manufactured home, or mobile home where not prohibited by local codes.

This appliance is only for use with type of gas indicated on the rating plate. This appliance is

not convertible for use with other gases,

unless a certified kit is used.

IMPORTANT: PLEASE READ THE FOLLOWING CAREFULLY Remove any plastic from trim parts before turning the fireplace On. It is normal for fireplaces fabricated of steel to give off some expansion and/ or contraction noises during the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or car engine. It is not unusual for a Vermont Castings, Majestic Products gas fireplace to give off some odor the first time it is burned. This is due to the manufacturing process.

Please open all windows to ensure your room is well ventilated. It is recommended that you burn your fireplace for at least ten (10) hours the first time you use it. If the optional fan kit has been installed, place the fan switch in the “Off” position during this time.

Locating Your Fireplace

E A B

Y

D

Y B

F

LU584-R

Fig. 1 Locating Your Gas Fireplace

A) Flat on wall B) Cross corner C) Island** D) Room divider*/ ** E) Flat on wall corner* F) Chase installation Y) 6 in. minimum

* When you install your Vermont Castings, Majestic Products fireplace in (D) Room divider or (E) Flat on wall corner positions, a minimum of (Y), 6 in. (153 mm) clearance must be maintained from the perpendicular wall and the front side edge of the fireplace. ** Island (C) and Room Divider (D) installation is possible if the horizontal portion of the vent system (X) does not exceed 20 ft. (610 cm). See details in Venting Section.

10004920

Page 4 of the Vermont Casting DVR33 user manual — Installation and Operating Instructions
Page 4 · click to enlarge
Page 4
Vermont Casting DVR33 — Installation and Operating Instructions diagram (page 4)
Fig. 3 · Installation and Operating Instructions
Fireplace Dimensions CL S Rough E 4" Dia.(102mm) Opening 7" Dia.(178mm) Depth L G O F Recessed Nailing Flange ⁵⁄₈" Rough Opening Width 33¹⁄₂" (16mm) ¹⁄₂" (13mm) N L Rough M Opening Height 1" (25mm) P B H B C R Electrical Gas Line T Access Access (102mm) 4" - U 2" D A 1" I J 2" (52mm) (52mm) (25mm) K Q Fig. 2 Fireplace specifications and framing dimensions. Appliance Dimensions A33”838 mm B287/8”733 mm C16 3/8”416 mm D31”787 mm E221/16”560 mm F111/2”292 mm G143/4”375 mm H241/2”622 mm I5”127 mm J71/2”127 mm K81/2”216 mm R31”787 mm S161/2”419 mm T191/2”495 mm U8”208 mm Framing Dimensions L36”914 mm M51”1295 mm N251/2”648 mm O12”305 mm P29”737 mm Q331/2”851 mm

10004920

Page 5 of the Vermont Casting DVR33 user manual — CFM174
Page 5 · click to enlarge
Page 5

Clearance to Combustibles

Top 0” (0 mm) Bottom 0” (0 mm) Side 0” (0 mm) Back 0” (0 mm) Venting Concentric sections of DV Vent 1” (25 mm) Non-concentric sections of DV Vent

J

F G H I

Sides and bottom 1” (25 mm) Top 2” (50 mm)

K

Mantels

M

N

O

Side of Combustion Chamber

V W X Y Z A B C D E Fireplace Top Louvre Assembly Top of Combustion Chamber Bottom of Door Trim CFM146 Mantel Shelf Dimensions (Minimum Height) Ref.Mantel Shelf DepthRef.Height above Firebox V10" (254 mm)A17" (432 mm) W8" (203 mm)B15" (381 mm) X6" (152 mm)C13" (330 mm) Y4" (101 mm)D11" (279 mm) Z2" ( 50 mm )E9" (229 mm)

Mantel Leg Dimensions (Minimum Width)

Mantel Mantel Leg from Side of Ref. Leg Depth Ref. Combustion Opening

F 10" (254 mm) K 11 1/2" (292 mm) G 8" (203 mm) L 9 1/2" (241 mm) H 6" (152 mm) M 7 1/2" (191 mm) I 4" (101 mm) N 5 1/2" (140 mm) J 2" ( 50 mm ) O 3 1/2" ( 89 mm )

Fig. 4b Mantel leg dimensions

Hearth

A hearth is not mandatory, but is recommended for aesthetic purposes. We recommend using a noncombustible hearth which projects out 12” (305 mm) or more from the front of the fireplace.

Cold climate installation recommendation: When installing this unit against a noninsulated exterior wall or chase, it is mandatory that the outer walls be insulated to conform to applicable insulation codes.

Fig. 4a Combustible mantel leg minimum installation

CFM174

Show 7 more labels / short text on this page
Appliance · Mantel Leg · Black Surround Face · Mantel Leg · CFM164b · CFM166a · 10004920
Page 6 of the Vermont Casting DVR33 user manual — FP1023
Page 6 · click to enlarge
Page 6

Framing and Finishing

Final Finishing

Check fireplace to make sure it is levelled and properly positioned.

Noncombustible materials such as brick or tile may be extended over the edges of the face of the appliance. DO NOT cover the window frame assembly, any vent, louvre assembly top or louvre assembly bottom. If a Trim Kit is going to be installed on the fireplace, the brick or tile will have to be installed flush with the edges of the appliance.

1. Choose the unit location.
2. Place the unit into position and secure it to the floor with 1.5” (38 mm) screws, or nails. The holes to secure the unit to floor are located just behind the access door grille on the left and right side of the unit.
3. Frame in the fireplace with a header across the top. It is important to allow for the finished wall face when setting the depth of the frame.
Gas Specifications Max. Input BTU/hMin. Input BTU/h ModelFuelGas Control DVR33RNNatMillivolt20,00014,000 DVR33RPPropMillivolt20,00015,000 DVR33ENNat24 V Hi/Lo20,00014,000 DVR33EPProp24 V Hi/Lo20,00015,000
4. Attach the fireplace to the frame using the adjustable frame drywall strips (located behind the access door for shipping). Preset the depth to suit the facing material of the wall. The strips are adjustable to 1/2” (13 mm), 5/8” (16 mm), or 3/4” (19 mm). (Fig. 5)
5. Screw through the slotted holes in the drywall strip and into predrilled holes in fireplace side. Measure from face of fireplace to the face of the drywall strip to confirm the final depth.
Gas Inlet and Manifold Pressures Inlet MinimumNaturalLP (Propane) 5.5” w.c.11” w.c. Inlet Maximum14” w.c.14” w.c. Manifold Pressure3.5” w.c.10” w.c.

A

B

Screw Drywall Position Depths A 1/2” (13 mm) B 5/8” (16 mm) C 3/4” (19 mm)

DVR33 CERTIFIED TO

ANSI Z21.88-2002 / CSA 2.33-2002

Vented Gas Fireplace Heaters

High Elevations

Adjustable 1/2”, 5/8” & 3/4” Spacing

Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4,500 feet (1,370 m) above sea level.

FP1023

Fig. 5 Adjustable drywall strip (nailing flanges).

For elevations above 4,500 feet (1,370 m) in USA, installations must be in accordance with the current ANSI Z223.1 and/or local codes having jurisdiction.

In Canada, please consult provincial and/or local authorities having jurisdiction for installations at elevations above 4,500 feet (1,370 m).

Adjustable Drywall Strip · (Nailing Flange) · 10004920

Page 7 of the Vermont Casting DVR33 user manual — Alternate Switch Location
Page 7 · click to enlarge
Page 7
Vermont Casting DVR33 — Alternate Switch Location diagram (page 7)
Fig. 4 · Alternate Switch Location
Vermont Casting DVR33 — Alternate Switch Location diagram (page 7)
Fig. 5 · Alternate Switch Location

Do not wire the remote ON/OFF wall switch for this gas appliance into a 120 V power supply.

When purging the gas lines, the front glass must be removed.

The gas pipeline can be brought in through the side of the fireplace as well as the bottom. Knockouts are provided on the bottom behind the valve to allow for the gas pipe installation and testing of any gas connection. It is most convenient to bring the gas line in from the rear right side of the valve as this allows fan installation or removal without disconnecting the gas line.

1. Thread the wiring through the electrical knockout located on either side of the unit. Take care not to cut the wire or insulation on metal edges. Ensure the wire is secured and protected from possible damage. Run one end of the gas control valve and the other end to the conveniently located wall switch.
2. Attach the wire to the ON/OFF switch and install the switch into the receptacle box. Attach the cover plate to the switch.

The gas line connection can be made with properly tinned 3/8” copper tubing, 3/8” rigid pipe or an ap- proved flex connector. Since some municipalities have additional local codes, it is always best to consult your local authority and the CSA-B149.1 installation codes.

3. Connect the wire to the gas control valve (Fig. 7).
Vermont Casting DVR33 — Alternate Switch Location diagram (page 7)
Fig. 6 · Alternate Switch Location

For USA installations consult the current National Fuel Gas Code, ANSI Z223.1.

Vermont Casting DVR33 — Alternate Switch Location diagram (page 7)
Fig. 7 · Alternate Switch Location

Fig. 7 Remote switch wiring diagram for RN or RP models.

Fig. 6 Typical gas supply installation.

Alternate Switch Location

Always check for gas leaks with a mild soap and water solution applied with a brush no larger than 1” (25 mm). Never apply soap and water solution with a spray bottle. Do not use an open flame for leak testing.

The remote switch can be installed on either side of the access door. Mount the switch to the bracket provided and screw the bracket to either side of the frame, using the prepunched holes (Fig. 8).

Vermont Casting DVR33 — Alternate Switch Location diagram (page 7)
Fig. 8 · Alternate Switch Location

Do not subject the fireplace valve to test pressures exceeding 1/2 p.s.i. Isolate, or disconnect this and any other gas appliance control from the gas line when pressure testing.

The gas control is equipped with a captured screw type pressure test point; therefore, it is not necessary to provide a 1/8" test point up stream of the control.

When using copper or flex connector use only ap- proved fittings. Always provide a union when using black iron pipe so that the gas line can be easily disconnected for burner or fan servicing (Fig. 6). See the gas specification for pressure details and ratings.

Fig. 8 Alternate switch location.

10004920

Page 8 of the Vermont Casting DVR33 user manual — FP580
Page 8 · click to enlarge
Page 8

EB-1 Electrical Box

Retaining Screw The fireplace, when installed, must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code For USA installations, follow the local codes and the national electrical code ANSI/NFPA No. 70. It is strongly suggested that EB-1 Electrical Junction Box wiring be carried out by a licensed electrician. Ensure that the power to the supply line has been disconnected before commencing this procedure.

The EB-1 electrical junction box has been supplied standard with this model to allow for easy installation of an optional fan kit.

To connect the EB-1 box to the house electrical supply follow the steps below. 1. Unscrew the retaining screw from the EB-1 base plate (Fig. 9), and remove the EB-1 assembly from the fireplace. 2. Remove the front cover of the EB-1 box. 3 Remove the plug socket assembly from the EB-1 box. 4. Feed the supply line in from the outside through the cable clamp (Fig. 9).

FP580

Fig. 9 EB-1 receptacle.

5. Connect black wire of the power supply line to the brass screw (polarized) of the socket assembly. 6. Connect the white wire of the power line to the chrome screw of the socket assembly. 7. Connect the ground wire of the supply line to the green screw of the socket assembly. 8. Refit the socket assembly back into the electrical box and replace the cover plate. Secure the cable with the clamp on the outside of the unit to prevent strain on the connections. 9. The EB-1 electrical junction box is now ready to supply power to the FK-12 or FK-24 fan kits, if so fitted.

Show 6 more labels / short text on this page
Inside · Electrical Box · Front of Unit · Outside · Front of Unit · 10004920
Page 9 of the Vermont Casting DVR33 user manual — General Venting Information
Page 9 · click to enlarge
Page 9

Electronic Gas Control Valve

This appliance may be fitted with a Honeywell Ignition Module.

To install the remote On/Off starter switch on electronic ignition units (Fig. 10):

1. Thread the wiring through the holes on the side panels of the appliance. Take care not to cut the wire or insulation on metal edges. Route the wire to a conveniently located receptacle box. 2. Attach the wire to the On/Off switch and install the switch into the receptacle box. 3. Connect the White wire from the wall switch to the Black wire from the transformer, using an approved wire nut. Connect the Black wire from the wall switch to the Black wire running from the #6 position of the ignition module, also using an approved wire nut.

PILOT

HONEYWELL IGNITION MODULE

MV MV/VP PV GRD 24V SENSE SPARK

1 2 3 4 5 6 8 9

GREEN

ORANGE

RED

ORANGE

LO

HI

NOVA SIT 822 VALVE

BLUE

WHITE

POWER CORD W/FEMALE SPADE

24 VAC HOT

120 VAC RTN

BLACK

WHITE

BLACK

OFF

WHITE

BLACK

YELLOW

GREEN

24 VAC RET

120 VAC HOT

40VA TRANSFORMER

WALL SWITCH

BLACK WHITE

Fig. 10 Honeywell Ignition Module.

General Venting Information

  • Your fireplace is approved to be vented either through the side wall, or vertically through the roof.
  • Only venting components specifically approved and labeled for this fireplace may be used.
  • Venting terminals shall not be recessed into a wall or siding.
  • Horizontal venting must be installed on a level plane without any incline or decline.

Do not locate termination hood where excessive snow or ice build up may occur. Be sure to check vent termination area after snow falls, and clear to prevent accidental blockage of venting system. When using snow blowers, make sure snow is not directed towards vent termination area.

Location of Vent Termination

It is imperative to observe minimum clearances (shown on the following page) when locating vent terminations.

There must not be any obstruction such as bushes, garden sheds, fences, decks or utility buildings within 24" from the front of the termination hood.

10004083-Fig1 · 10004920

Page 10 of the Vermont Casting DVR33 user manual — Electronic Gas Control Valve
Page 10 · click to enlarge
Page 10
General Venting Information–Termination Location INSIDE CORNER DETAIL G V D A H N N E V B C B V L V Fixed B V Closed V Fixed Operable Closed G Operable F V V B B B V J X M G A I V K X V A V VENT TERMINATION X AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED CFM145a Canadian Installations1US Installations2 A = Clearance above grade, veranda, porch, deck or balcony12 in. (30 cm)12 in. (30 cm) B = Clearance to window/door that may be opened6 in. (15 cm) for appliances <10,000 Btuh (3 kW); 12 in (30 cm) for appliances >10,000 Btuh (3 kW) and <100,000 Btuh (30 kW); 36 in. (91 cm) for appliances >100,000 Btuh (30 kW)6 in. (15 cm) for appliances <10,000 Btuh (3 kW); 9 in. (23 cm) for appliances >10,000 Btuh (3 kW) and <50,000 Btuh (15 kW); 12 in. (30 cm) for appliances >50,000 Btuh (15 kW) C = Clearance to permanently closed window12 in. (305 mm) recommended to prevent window condensation12 in. (305 mm) recommended to prevent window condensation D = Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 ft. (610 mm) from the center line of the terminal18 in. (458 mm)18 in. (458 mm) E = Clearance to unventilated soffit12 in. (305 mm)12 in. (305 mm) F = Clearance to outside corner(See next page.)(See next page.) G = Clearance to inside corner(See next page.)(See next page.) H = Clearance to each inside of center line extended above meter/regulator assembly3 ft. (91 cm) within a height of 15 ft. (4.57 m) above the meter/regulator assembly3 ft. (91 cm) within a height of 15 ft. (4.57 m) above the meter/regulator assembly I = Clearance to service regulator vent outlet3 ft. (91 cm)3 ft. (91 cm) J = Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance6 in. (15 cm) for appliances <10,000 Btuh (3 kW); 12 in. (30 cm) for appliances >10,000 Btuh (3 kW) and <100,000 Btuh (30 kW); 36 in (91 cm) for appliances >100,000 Btuh (30 kW)6 in. (15 cm) for appliances <10,000 Btuh (3 kW); 9 in. (23 cm) for appliances >10,000 Btuh (3 kW) and <50,000 Btuh (15 kW); 12 in. (30 cm) for appliances >50,000 Btuh (15 kW) K = Clearance to a mechanical air supply inlet6 ft. (1.83 m)3 ft. (91 cm) above if within 10 ft. (3.05 m) horizontally L = Clearance above paved sidewalk or a paved driveway located on public property7 ft. (2.13 m)†7 ft. (2.13 m)† M = Clearance under veranda, porch, deck or balcony12 in. (30 cm)‡12 in. (30 cm)‡ N = Clearance above a roof shall extend a minimum of 24” (610 mm) above the highest point when it passes through the roof surface, and any other obstruction within a horizontal distance of 18” (450 mm). 1 In accordance with current CSA-B149 Installation Codes. 2 In accordance with current ANSI Z223.1/NFPA 54 National Fuel Gas Codes. † A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single-family dwellings, and which serves both dwellings. ‡ Only permitted if veranda/porch/deck is fully open on a of minimum two sides beneath the floor. NOTES: • Local codes or regulations may require different clearances. • The special venting system used on Vermont Castings, Majestic Products Direct Vent Fireplaces are certified as part of the appliance, with clearances tested and approved by the listing agency.

Fig. 11 Vent termination clearances

10004920

Page 11 of the Vermont Casting DVR33 user manual — Electronic Gas Control Valve
Page 11 · click to enlarge
Page 11
Vermont Casting DVR33 — Electronic Gas Control Valve diagram (page 11)
Fig. 9 · Electronic Gas Control Valve

Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors.

C = Maximum depth of 48" (1219mm) for recessed location. D = Minimum width for back wall of a recessed location. Combustible 38"(965mm) Noncombustible 24"(610mm)

E = Clearance from corner in recessed location. Combustible 6"(152mm) Noncombustible 2"(50mm)

Fig. 12 Termination clearances.

Vermont Casting DVR33 — Electronic Gas Control Valve diagram (page 11)
Fig. 10 · Electronic Gas Control Valve

Before joining elbows and pipes, apply a bead of high temperature sealant to the crimped end of the elbow or pipe.

Join the pipes using a 2” (50 mm) overlap and secure the joints with three sheet metal screws (Fig. 13). Wipe off excess sealant. Canadian Installations: The venting system must be installed in accordance with the current CSA-B149.1 installation code. USA Installations: The venting system must conform to local codes and/ or the current National Fuel Code ANSI Z223.1. Only venting components manufactured by Vermont Castings, Majestic Products may be used in Direct Vent systems.

Fig. 13 Apply a bead of high temperature sealant.

10004920

Page 12 of the Vermont Casting DVR33 user manual — Step 2
Page 12 · click to enlarge
Page 12

Twist Lock Pipes

Max. 20" (508 mm)

When using Vermont Castings, Majestic Products twist-lock pipe it is not necessary to use sealant on the joints. The only areas of the venting system that need to be sealed with high temperature silicone sealant are the collars on the fireplace and termination, and the sliding joint of any telescopic vent section used in the system.

Top view flat installation

To join twist lock pipes together, simply align the beads of the male end with the grooves of the female end, twisting the pipe until the flange on the female end contacts external flange on the male end. It is recom- mended that you secure the joints with three (3) sheet metal screws, however this is not mandatory with twist lock pipe (Fig. 14).

Max. 20" (508 mm)

To make it easier to assemble the joints we suggest putting a lubricant (Vaseline or similar) on the male end of the twist lock pipe prior to assembly.

Top view corner installation FP1188

Male End Female End

Fig. 15 Rear vent application, maximum horizontal distance.

Rear Wall Vent Installation

Step 1

Locate and cut the vent opening in the wall.

TWL100

For combustible walls first frame in opening (Fig. 16).

Fig. 14 Twist-Lock pipe joints.

Combustible Walls: Cut a 10³⁄₈”H x 9³⁄₈” W (265 mm x 240 mm) hole through the exterior wall and frame as shown.

Rear Wall Vent Application

Noncombustible Walls: Hole opening should be 7¹⁄₂” (190 mm) in diameter.

  • When installed as a rear vent unit this appliance may be vented directly to a termination located on the rear wall behind the appliance
  • Only Vermont Castings, Majestic Products venting components are approved to be used in these applications (See Venting Components listedfor different installation requirements).
  • The maximum horizontal distance between the rear of the appliance (or end of the transition elbow in a corner application) and the outside face of the rear wall is 20” (508 mm) (Fig. 15).
  • Only one 45˚ elbow is allowed in these installations.
  • The minimum clearances between any combustible material and the vent pipe sections are:

Zero clearance sleeve is only required for combustible walls.

Step 2

Measure wall thickness, and cut zero clearance sleeve to proper length; i.e., max. 12” (304.8 mm). Assemble sleeve to its maximum opening (103⁄8” x 93⁄8”) and attach to firestop with #8 sheet metal screws (supplied). Install firestop assembly (Fig. 17). Step 3

Measure the horizontal length requirement for the venting including a 2” (50 mm) overlap, i.e. from the elbow to the outside wall face plus 2” (50 mm) (Fig. 15).

Top 2” (50 mm) Sides 1” (25 mm) Bottom 1” (25 mm)

Screw Holes · 10004920

Page 13 of the Vermont Casting DVR33 user manual — Step 5
Page 13 · click to enlarge
Page 13
Vermont Casting DVR33 — Step 4 diagram (page 13)
Fig. 11 · Step 4
Vermont Casting DVR33 — Step 4 diagram (page 13)
Fig. 12 · Step 4

Fig. 16 Vent opening, side wall.

Fig. 18 Flat to the wall installation.

Vermont Casting DVR33 — Step 4 diagram (page 13)
Fig. 13 · Step 4

Fig. 17 Zero clearance sleeve.

Step 4

Install the 4” (100 mm) vent to the appliance collar and secure with 3 sheetmetal screws. Install the 7” (175 mm) vent pipe to the appliance collar and secure with 3 sheetmetal screws. It is not necessary to seal this connection. If a 45˚ elbow is being used attach the elbow to the appliance in the same manner then attach the venting to the elbow.

It is critical that there is no downward slope away from the appliance when connecting the vent or elbow.

Step 5

Guide the venting through the vent hole as you place the appliance in its installed position. Guide the 4” (100 mm) and 7” (175 mm) collars of the vent termination into the outer ends of the venting. Do not force the termination. If the vent pipes do not align with the termination remove and realign the venting at the appliance flue collars (Fig. 18). Attach the termination to the wall as outlined in the instruction sheet supplied with the termination.

10004920

Page 14 of the Vermont Casting DVR33 user manual — CFM102
Page 14 · click to enlarge
Page 14

How To Use the Vent Graph

Vertical Sidewall Application

The Vent Graph should be read in conjunction with the following vent installation instructions to determine the relationship between the vertical and horizontal dimensions of the vent system.

Since it is very important that the venting system maintain its balance between the combustion air intake and the flue gas exhaust, certain limitations as to vent configurations apply and must be strictly adhered to.

1. Determine the height of the center of the horizontal vent pipe exiting through the outer wall. Using this dimension on the Sidewall Vent Graph (Fig. 19), locate the point intersecting with the slanted graph line. 2. From the point of this intersection, draw a vertical line to the bottom of the graph. 3. Select the indicated dimension, and position the fireplace in accordance with same. Example A: If the vertical dimension from the floor of the fire- place is 11’ (3.4 m) the horizontal run to the face of the outer wall must not exceed 14’ (4.3 m) Example B: If the vertical dimension from the floor of the unit is 7’ (2.14 m) the horizontal run to the face of the outer wall must not exceed 8¹⁄₂’ (2.6 m)

The Vent Graph, showing the relationship between vertical and horizontal side wall venting, will help to determine the various dimensions allowable.

Minimum clearance between vent pipes and com- bustible materials is one 1” (25 mm) on top, bottom and sides unless otherwise noted.

When vent termination exits through foundations less than 20” (508 mm) below siding outcrop, the vent pipe must flush up with the siding.

It is best to locate the fireplace a way that minimizes the number of offsets and horizontal vent length.

The horizontal vent run refers to the total length of vent pipe from the flue collar of the fireplace (or the top of the Transition Elbow) to the face of the outer wall.

Horizontal plane means no vertical rise exists on this portion of the vent assembly.

When installing the appliance as a rear vent unit, the 90° or 45° transition elbow attached directly to the rear of the unit is NOT INCLUDED in the following criteria and calculations. Unless this transition elbow is specifically mentioned, it should be ignored when calculating venting layouts.

Vertical Dimension From The Floor Of the unit To The Centre Of The Horizontal Vent Pipe

(3) x 90 degree elbows

Min. 7.5' (2.3 m)

egA
egB

Max. 20' (6.1 m)

3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

Horizontal Dimension From the Outside Face of the Wall to the Center of the Fireplace Vent Flange

Fig. 20 Maximum three (3) 90° elbows per installation.

Sidewall Vent Graph showing the relationship between vertical and horizontal dimensions for a Direct Vent flue system.

  • The maximum number of 90˚ elbows per side wall installation is three (3) (Fig. 20).

CFM102

Fig. 19 Sidewall venting graph. (Dimensions in feet.)

10004920

Page 15 of the Vermont Casting DVR33 user manual — How To Use the Vent Graph
Page 15 · click to enlarge
Page 15
Vermont Casting DVR33 — How To Use the Vent Graph diagram (page 15)
Fig. 14 · How To Use the Vent Graph

As shown in Fig. 22, the total of dimension A and B is not to be greater than 17’ (5.2 m).

  • The maximum number of 45˚ elbows permitted per side wall installation is two (2). These elbows can be installed in either the vertical or horizontal run.
  • For each 45˚ elbow installed in the horizontal run, the length of the horizontal run MUST be reduced by 18” (45 cm). This does not apply if the 45˚ elbows are installed on the vertical part of the vent system.
  • The maximum number of elbow degrees in a system is 270˚ (Fig. 23). Example:

Elbow 1 = 90˚ Elbow 2 = 45˚ Elbow 3 = 45˚ Elbow 4 = 90˚ Total angular variation = 270˚

Vermont Casting DVR33 — How To Use the Vent Graph diagram (page 15)
Fig. 15 · How To Use the Vent Graph
  • If a 90˚ elbow is used in the horizontal vent run (level height maintained), the maximum horizontal vent length is reduced by 36” (914 mm) (Fig. 22). This does not apply if the 90˚ elbows are used to increase or redirect a vertical rise (Fig. 20). Example: According to the vent graph (page 14), the maximum horizontal vent length in a system with a 7.5’ (2.3 mm) vertical rise is 20’ (6 m), and if a 90˚ elbow is required in the horizontal vent, it must be reduced to 17’ (5.2 m).

1 + 2 + 3 + 4 = 270º

Vermont Casting DVR33 — How To Use the Vent Graph diagram (page 15)
Fig. 16 · How To Use the Vent Graph

Fig. 22 Maximum vent run with elbows.

10004920

Page 16 of the Vermont Casting DVR33 user manual — Step 2
Page 16 · click to enlarge
Page 16
Vermont Casting DVR33 — Vertical Sidewall Installation diagram (page 16)
Fig. 17 · Vertical Sidewall Installation

Vertical Sidewall Installation

Step 1

Locate vent opening on the wall. It may be necessary to first position the fireplace and measure to obtain hole location. Depending on whether the wall is combustible or noncombustible, cut opening to size. (For combustible walls, frame in opening first (Fig. 24).

Combustible Walls: Cut a 9³⁄₈”H x 9³⁄₈” W (240 mm x 240 mm) hole through the exterior wall and frame.

Noncombustible Walls: Hole opening must be 7¹⁄₂” (190 mm) in diameter.

Vermont Casting DVR33 — Vertical Sidewall Installation diagram (page 16)
Fig. 18 · Vertical Sidewall Installation

Fig. 26 Vertical height requirements.

Step 3

Place fireplace into position. Measure the vertical height (X) required from the base of the flue collars to the center of the wall opening (Fig. 26). Step 4

Apply a bead of high temperature silicone sealant to the inner and outer flue collars of the fireplace and using appropriate length of pipe section(s) attach to fireplace with three (3) screws. Follow with the installa- tion of the inner and outer elbow, again secure joints as described in the ‘Connecting Vent Pipe’ section. Step 5

Measure the horizontal length requirement including a 2” (50 mm) overlap, i.e. from the elbow to the outside wall face plus 2” (50 mm)—or the distance required if installing a second 90˚ elbow (Fig. 27).

Always install horizontal venting on a level plane.

Fig. 25 Adjustable zero clearance sleeve.

Step 6

Use the appropriate length of pipe sections—telescopic or fixed—and install. The sections which go through the wall are packaged with the starter kit, and can be cut to suit if necessary.

Zero clearance sleeve is required only for combustible walls.

Step 2

Measure wall thickness and cut zero clearance sleeve parts to proper length (12” [305 mm] max.). Assemble sleeve and attach to firestop with #8 sheetmetal screws (supplied). Install firestop assembly (Fig. 25).

high temperature sealant will restrict cold air being drawn in around fireplace.

10004920

Page 17 of the Vermont Casting DVR33 user manual — Below Grade Installation
Page 17 · click to enlarge
Page 17
Vermont Casting DVR33 — Step 7 diagram (page 17)
Fig. 19 · Step 7

If installing a snorkel, a minimum 24” (610 mm) vertical rise is necessary. The maximum horizontal run with the 24” (610 mm) vertical pipe is 36” (915 mm). This measurement is taken from the collar of the fireplace (or transition elbow) to the face of the exterior wall. See the Sidewall Venting Graph for extended horizontal run if the vertical exceeds 24” (610 mm).

1. Establish vent hole through the wall (Fig. 24, page 16).
2. Remove soil to a depth of approximately 16” (406 mm) below base of snorkel. Install drain pipe. Install window well (not supplied). Refill hole with 12” (305 mm) of coarse gravel leaving a clearance of approximately 4” (100 mm) below snorkel (Fig. 28).
3. Install vent system.
4. Ensure a watertight seal is made around the vent pipe coming through the wall.

Fig. 27 Horizontal length requirement.

5. Apply high temperature sealant caulking (supplied) around the 4” and 7” snorkel collars.

Step 7

6. Slide the snorkel into the vent pipes and secure to the wall.

Apply high temperature sealant to 4” (100 mm) and 7” (175 mm) collars or the termination one inch away from crimped end. Guide the vent terminations 4” and 7” collars into their respective vent pipes. Double check that the vent pipes overlap the collars by 2” (50 mm).

7. Level the soil so as to maintain a 4” clearance (100 mm) below snorkel (Fig. 28).
Vermont Casting DVR33 — Step 7 diagram (page 17)
Fig. 20 · Step 7

Secure the termination to the wall with screws provided and caulk around the wall plate to weatherproof.

As an alternative to screwing the termination directly to the wall, you may also use expanding plugs or an approved exterior construction adhesive. Or, you may attach the termination with screws through the inner body into the 4” vent pipe—however, for this method, you must extend the 4” pipe approximately 6” (150 mm) beyond the outer face of the wall.

Support horizontal pipes every 3’ (91 cm) with metal pipe straps.

Below Grade Installation

Minimum 24" (608 mm) vertical pipe must be installed when using 7DVSKS Kit.

When it is not possible to meet the required vent terminal clearances of 12” (305 mm) above grade level, a Snorkel Vent Kit #7DVSKS is recommended. It allows installation depth down to 7” (178 mm) below grade level. The 7” (178 mm) is measured from the center of the horizontal vent pipe as it penetrates through the wall.

Do not backfill around snorkel. A clearance of at least 4” (102 mm) must be maintained between the snorkel and the soil.

are observed. If the venting system is installed below ground, we recommend a window well with adequate and proper drainage to be installed around the termination area.

10004920

Page 18 of the Vermont Casting DVR33 user manual — Vertical Through-the-Roof Applications
Page 18 · click to enlarge
Page 18
  • Up to two 45 ° elbows may be used within the horizontal run. For each 45 ° elbow used on the horizontal plane, the maximum horizontal length must be reduced by 18” (450 mm). Example: Maximum horizontal length

If the foundation is recessed, use recess brackets (not supplied) for securing lower portion of the snorkel.

Fasten brackets to wall first, then secure to snorkel with self drilling #8 x 1/2 sheet metal screws. It will be necessary to extend vent pipes out as far as the protruding wall face (Fig. 29).

No elbows = 10’ (3 m) 1 x 45° elbows = 8.5’ (2.6 m) 2 x 45° elbows = 7’ (2.1 m) • A minimum of an 8’ (2.5 m) vertical rise is required.

Vermont Casting DVR33 — Vertical Through-the-Roof Applications diagram (page 18)
Fig. 21 · Vertical Through-the-Roof Applications
  • Two sets of 45 ° elbows offsets may be used within the vertical sections. From 0 to a maximum of 8’ (2.5 m) of vent pipe can be used between elbows (Fig. 30).
  • 7DVCS supports offsets (Fig. 32). This application will require that you first determine the roof pitch and use the appropriate starter kit. (See Venting Components List).
  • The maximum angular variation allowed in the system is 270 ° (Fig. 31).
  • The minimum height of the vent above the highest point of penetration through the roof is 2’ (610 mm) (Fig. 33).

Fig. 29 Snorkel installation, recessed foundation.

Vertical Through-the-Roof Applications

Vermont Casting DVR33 — Vertical Through-the-Roof Applications diagram (page 18)
Fig. 22 · Vertical Through-the-Roof Applications

This Gas Fireplace has been approved for, • Vertical installations up to 40’ (12 m) in height. Up to a 10’ (3 m) horizontal vent run can be installed within the vent system using a maximum of two 90° elbows (Fig. 30).

Vermont Casting DVR33 — Vertical Through-the-Roof Applications diagram (page 18)
Fig. 23 · Vertical Through-the-Roof Applications

Fig. 31 Maximum elbow usage.

10004920

Page 19 of the Vermont Casting DVR33 user manual — Vertical Through-the-Roof Installation
Page 19 · click to enlarge
Page 19

Vertical Through-the-Roof Installation

Vermont Casting DVR33 — Vertical Through-the-Roof Installation diagram (page 19)
Fig. 24 · Vertical Through-the-Roof Installation

1. Locate your fireplace. 2. Plumb to center of the (4”) flue collar from ceiling above and mark position. 3. Cut opening equal to 93/8” x 93/8” (240 mm x 240 mm). 4. Proceed to plumb for additional openings through the roof. In all cases, the opening must provide a minimum of 1 inch clearance to the vent pipe, i.e., the hole must be at least 93/8” x 93/81 (240 mm x 240 mm). 5. Place fireplace into position. 6. Place firestop(s) #7DVFS or Attic Insulation Shield #7DVAIS into position and secure (Fig. 32). 7. Install roof support (Fig. 33) and roof flashing, making sure upper flange is below the shingles (Fig. 34). 8. Install appropriate pipe sections until the venting is above the flashing (Fig. 34). 9. Install storm collar and seal around the pipe. 10. Add additional vent lengths for proper height (Fig. 33). 11. Apply high temperature sealant to 4” and 7” collars of vertical vent termination and install.

Fig. 32 Venting supports.

Vermont Casting DVR33 — Vertical Through-the-Roof Installation diagram (page 19)
Fig. 25 · Vertical Through-the-Roof Installation

If a room is above ceiling level, a firestop spacer must be installed on each level (top and bottom) of the ceiling joists. If an attic is above ceiling level, a 7DVAIS (Attic Insulation Shield) must be installed. Always face the enlarged ends of the vent section downward.

Vermont Casting DVR33 — Vertical Through-the-Roof Installation diagram (page 19)
Fig. 26 · Vertical Through-the-Roof Installation

Fig. 34 Roof flashing.

Fig. 32 Attic insulation shield and firestop spacer.

10004920

Page 20 of the Vermont Casting DVR33 user manual — DVR33 Bracket Restricter Installation
Page 20 · click to enlarge
Page 20

DVR33 Bracket Restricter Installation

through-the-roof configured flue system, the bracket restricter supplied with the appliance (part# 10002910) should be fitted to the appliance at installation.

For DVR33 numbers A12H00, A12I00, A14A00 and A14B00 only, the restricter plate for the vertical termination (part# 10003246) must be installed for vertical runs over 20’ (6.1 m). Fitting the Bracket Restricter

Fig. 36 Top face of baffle assembly

1. Remove the window glass/frame assembly. Locate the baffle firebox assembly in the top rear of the firebox (Fig. 35). 2. Remove the four (4) nuts along the front edge, and the three (3) screws along the rear edge of the baffle assembly. Remove the baffle assembly from the firebox. 3. Remove the two (2) screws from the top face of the baffle assembly (Fig. 36). Place the bracket restricter as it is shown in Fig. 37, and secure it by refitting the screws. 4. Refit the baffle assembly to the firebox, replacing the three (3) screws and four (4) nuts. 5. Refit window glass/frame per the appropriate sections.

Fig. 37 Assembling bracket restricter to baffle assembly

Fig. 35 Baffle firebox assembly

Baffle firebox assembly · 10004920

Page 21 of the Vermont Casting DVR33 user manual — Twist Lock Venting Components
Page 21 · click to enlarge
Page 21

Twist Lock Venting Components

7DVRVT - Through-the-Wall Rear Vent Termination

Starter Kit-Model 7TDVSK - Sidewall Venting Starter Kit-Model 7TDVSKV - Vertical Venting

for 7TDVSKV-A order 1/12 to 6/12 roof pitch for 7TDVSKV-B order 7/12 to 12/12 roof pitch for 7TDSKV-F order flat roof Starter Kit-Model 7TDVSKS - Snorkel Kit

for Below Grade Installation

45˚ elbow kit 7TDVT45 for Vertical Installation Offsets 7TDR45 for Rear Vent Application

90˚ Transition elbow kit 7TDVRT90 for Vertical Sidewall Applications or through-the-roof.

7TDVP1218 -12” to 18” adjustable length 7TDVP3564 -35” to 64” adjustable length

Pipe sections for vertical or horizontal venting

Model 7TDVP8” 4 per box Model 7TDVP12” 4 per box Model 7TDVP24” 4 per box Model 7TDVP36” Model 7TDVP48”

Vertical/Horizontal Combination Offset Support

Show 7 more labels / short text on this page
Telescopic vent sections · Firestop Spacer · Model 7DVFS · Attic Insulation Shield · Model 7DVAIS · Model 7DVC · 10004920
Page 22 of the Vermont Casting DVR33 user manual — Crimped End Venting Components
Page 22 · click to enlarge
Page 22

Crimped End Venting Components

7DVRVT - Through the wall Rear Vent Termination

Starter Kit-Model 7DVSK - Sidewall Venting Starter Kit-Model 7TDVSKV - Vertical Venting

for 7DVSKV-A order 1/12 to 6/12 roof pitch for 7DVSKV-B order 7/12 to 12/12 roof pitch for 7DSKV-F order flat roof Starter Kit-Model 7TDVSKS-Snorkel Kit

for Below Grade Installation

45˚ elbow kit 7DVT45 for Vertical Installation Offsets 7DV45 for Rear Vent Application

90˚ Transition elbow kit 7DVRT90 for Vertical Sidewall Applications or through-the-roof.

7DVP610- 6” to 10” adjustable length 7DVP1018- 10” to 18” adjustable length 7DVP1834- 18” to 34” adjustable length 7DVP3466- 34” to 66” adjustable length

Pipe sections for vertical or horizontal venting

Model 7DVP8” 4 per box Model 7DVP12” 4 per box Model 7DVP24” 4 per box Model 7DVP36” Model 7DVP48”

Vertical/Horizontal Combination Offset Support

Show 7 more labels / short text on this page
Telescopic vent sections · Firestop Spacer · Model 7DVFS · Attic Insulation Shield · Model 7DVAIS · Model 7DVCS · 10004920
Page 23 of the Vermont Casting DVR33 user manual — Window Frame Assembly Removal
Page 23 · click to enlarge
Page 23

Operating Instructions

Glass Information

6. Tilt window frame assembly out slightly at the bottom, lift the frame up and away from the fireplace. 7. To replace window frame assembly, reverse this procedure.
  • Use only glass approved by Vermont Castings, Majestic Products on this fireplace.
  • The use of any non-approved replacement glass will void all product warranties.
  • Care must be taken to avoid breakage of the glass.
  • Under no circumstances should this appliance be operated without the front glass in place, or with the glass in a damaged condition.
  • Replacement glass (complete with gasket) is available through your Vermont Castings, Majestic Products dealer, and should only be installed by a licensed qualified service person.

Louvre Removal

To remove the louvre assembly top, lift the panel up and out from the fireplace (Fig. 38).

the bottom edge and swings down.

FP1191

Fig. 39 Window frame assembly removal.

Glass Cleaning

It is necessary to periodically clean the glass panel.

During start-up, it is normal for condensation to form on the inside of the panel. This condensation causes lint, dust and other airborne particles to cling to the surface of the glass.

Also, initial paint curing may deposit a slight film on the glass. It is therefore recommended the glass panel be cleaned two or three times with a non-ammonia-based household cleaner and warm water within the first few weeks of operation. We recommend using gas fireplace glass cleaner.

FP444

Fig. 38 Remove louvre assembly top.

After the initial cleaning process, clean the glass two or three times during each operating season, depending on the environment in the house.

Window Frame Assembly Removal

1. Turn the fireplace OFF (including the pilot). 2. If the unit has been operating, allow time for the components to cool. 3. Remove the louvre assembly top. 4. Open the louvre assembly bottom. 5. Release the two clamps along lower edge of the frame by pulling down on clamp handles (Fig. 39).

Clean the glass after the first two weeks of operation. Do not clean glass when it is hot. Do not use abrasive cleaners. Do not strike or slam the glass.

Show 8 more labels / short text on this page
Lower Clamps · Window Frame Assembly · Window Frame Assembly · Pull Clamp Hook · Push Clamp Handle · Louvre Assembly Top · Window Frame Assembly · 10004920
Page 24 of the Vermont Casting DVR33 user manual — A36
Page 24 · click to enlarge
Page 24

Lava Rock: (Part Number 10001454) Remove from packaging and spread over the sides of the burner housing. Do not place this material on the burner tiles.

Installation of Logs and Lava Rock Material

The logs are fragile and should be handled with care. Keep the packaging material out of the reach of children, and dispose of the material in a safe manner.

Vermont Casting DVR33 — Installation of Logs and Lava Rock Material diagram (page 24)
Fig. 27 · Installation of Logs and Lava Rock Material

During this procedure, refer to Fig. 40 for log identification.

1. Remove the top louvre assembly. 2. Remove the window frame assembly. See “Window Frame Assembly Removal” on page 23. 3. Fit the rear right log (A34) in place on the rear log support. The hole in the underside of the log fits over the pin on the right end of the support shelf. 4. Fit the front/rear left log (A33) in place on the rear log support. The hole in the underside of the log fits over the pin on the left end of the support shelf. 5. Fit the front right log (A35) in place, the top end of the log with the hole in the underside aligning with the knob on the rear right log (A34), and the other end with the cut slot resting on the right side edge of the front grate. 6. Fit the front center log (A36) on the center slot of the front grate. The flat end of this log sets against the back wall of the front grate plate.

Fig. 41 DVR33 Log Set Assembly.

allowed to be positioned at the front area (radiant portion) of the burner housing assembly.

Flame and Temperature Adjustment

RN/RP and EN/EP Models For units equipped with ‘HI/LO’ valves the flame adjustment is accomplished by rotating the ‘HI/LO’ adjustments knob located near the center of the gas control valve (Fig. 41 and Fig. 42).

Vermont Casting DVR33 — Flame and Temperature Adjustment diagram (page 24)
Fig. 28 · Flame and Temperature Adjustment

to increase flame height

to decrease flame height

A34 A33

A35

Fig. 41 Flame adjustment knob for Honeywell Valve.

A36

Fig. 40 DVR33 Log Set (top view)

The log set contains two types of lava rocks. Placing these materials is best done after the logs have been installed.

to decrease flame height

to increase flame height

Glowing Lava Rock: (Part Number 57897) Remove from the packaging and spread them over the burner tiles in a random fashion to fill the space highlighted in Fig 41.

Fig. 42 Flame adjustment knob for SIT Valve.

Show 9 more labels / short text on this page
Turn counterclockwise · Turn clockwise · Honeywell Valve · Honeywell · Turn counterclockwise · Turn clockwise · SIT Valve · Nova820 · 10004920
Page 25 of the Vermont Casting DVR33 user manual — Flame Characteristics
Page 25 · click to enlarge
Page 25

Flame Characteristics

Inspecting the Venting System

It is important to periodically perform a visual check of the pilot and burner flames. Compare them to the pictorials illustrated below (Fig. 43 and Fig. 44). If the flame patterns appear abnormal, contact a qualified service provider for service and adjustment.

This appliance venting system is designed and constructed to develop a positive flow adequate to remove flow gases to the outside atmosphere.

Any foreign objects in the venting system, except those designed specifically for the venting system, may cause spillage of flue gases.

Vermont Casting DVR33 — Flame Characteristics diagram (page 25)
Fig. 29 · Flame Characteristics

3/8” – 1/2”

To inspect the venting system, make sure the main gas valve is off. Remove the window frame assembly (Refer to Window Frame Assembly Removal section). Using a flashlight, check the area above the baffle in the combustion dome. Clean if necessary.

Fig. 44 Correct burner flame appearance.

10004920

Page 26 of the Vermont Casting DVR33 user manual — To Turn Off Gas To Heater
Page 26 · click to enlarge
Page 26

Lighting and Operating Instructions

FOR YOUR SAFETY, READ BEFORE LIGHTING

may result causing property damage, personal injury or loss of life.

  • If you cannot reach your gas supplier, call the Fire Department.

A. This heater has a pilot which must be lit manu-

ally. When lighting the pilot follow these instruc- tions exactly. B. BEFORE LIGHTING smell all around the heater

C. Use only your hand to push in or turn the gas

control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Applying force or any attempted repair may result in a fire or explosion.

  • area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS
  • Do not try to light any fireplace.
  • Do not touch any electric switch.
  • Do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

D. Do not use this fireplace if any part has been under

water. Immediately call a qualified service techni- cian to inspect the heater and to replace any part of the control system and any gas control which has been under water.

Lighting Instructions

1. STOP! Read the safety information above. 2. Turn off all electrical power to the fireplace. 3. For MN/MP/TN/TP appliances ONLY, go on to Step 4. For RN/RP appliances turn the On/Off switch to “OFF” position or set thermostat to lowest level. 4. Open control access panel. 5. Push in gas control knob slightly and turn clockwise to "OFF".

10. Push the control knob all the way in and hold. Immediately light the pilot by repeatedly depressing the piezo spark igniter until a flame appears. Continue to hold the control knob in for about one (1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8. • If knob does not pop up when released, stop and immediately call your service technician or gas supplier.

P

O

T

PILOT

OFF

F

ON

F P

O

F

ON

O

F

F

F

O

Euro SIT SIT NOVA Honeywell

6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you do not smell gas, go to the next step. 7. Remove glass door before lighting pilot. (See Glass Frame Removal section). 8. Visibly locate pilot by the main burner. 9. Turn knob on gas control counter-clockwise to "PILOT".
  • If after several tries, the pilot will not stay lit, turn the gas control knob to "OFF" and call your service technician or gas supplier. 11. Replace glass door. 12. Turn gas control knob to “ON” position. 13. For RN/RP appliances turn the On/Off switch to “ON” position or set thermostat to desired setting. 14. Turn on all electrical power to the fireplace.

To Turn Off Gas To Heater

1. Turn the On/Off switch to Off position or set the thermostat to lowest setting. 2. Turn off all electric power to the fireplace if service is to be performed.
3. Open louvre assembly bottom. 4. Push in gas control knob slightly and turn clockwise to "OFF". Do not force. 5. Close control access panel.
Show 4 more labels / short text on this page
o · t · 3/8" - 1/2" · 10004920
Page 27 of the Vermont Casting DVR33 user manual — 3/8" FLEX LINE (FROM VALVE)
Page 27 · click to enlarge
Page 27

Lighting and Operating Instructions

For Fireplaces equipped with SIT822 Gas Valve (EN or EP)

For your safety, read the following warnings

before lighting the appliance:

A. This fireplace is equipped with an ignition device

  • If you cannot contact your gas supplier call the Fire Department C. Use only your hand to push in or turn the gas

which automatically lights the pilot. DO NOT try to light the pilot by hand. B. BEFORE OPERATING, smell all around the

control knob. Never use tools. If the knob will not push in or turn by hand do not try to repair it, call a qualified service technician. Force or attempting repair may result in a fire or explosion. D. Do not use this appliance if any part has been

  • appliance area for gas. Be sure to smell next to the floor because some gas is heavier than the air and will settle on the floor. What to do if you smell gas
  • Do not try to light any appliance
  • Do not operate any electrical switch.
  • Do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas suppliers instructions.

under water. Immediately call a qualified service technician to inspect the appliance and replace any part of the control system and any gas control that has been under water.

Lighting Instructions

1. STOP! Read the safety information above before continuing.
5. Turn the remote switch, if used, OFF. Turn the wireless remote, if used, OFF.
2. Turn off all electrical power to the appliance.
6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas STOP. Follow instructions B in the safety warnings above. If you do not smell gas go onto the next step.
3. This appliance is equipped with an ignition device which automatically lights the pilot. DO NOT try to light the pilot by hand.
4. Access the gas control by lowering the lower access door (louvre assembly).
7. Close the access door.
8. Turn ON all electrical power to the appliance.
9. Turn remote switch or wireless remote to ON.
10. If the appliance will not operate, follow the instructions “Turning Off the Gas to the Appliance” (below), and call your service technician or gas supplier.

LO

HI

Turning Off the Gas to the Appliance

1. Turn the remote switch to the “OFF” position. 2. Turn OFF all electrical power to the fireplace if service is required. 3 Open the lower access panel. 4. Turn the shut-off valve on the flexible gas line to the “OFF” position.

1/2" GAS SUPPLY

1/2" NPTx 1/2" FLARE SHUT-OFF VALVE

3/8" FLEX LINE (FROM VALVE)

10004920

Page 28 of the Vermont Casting DVR33 user manual — M
Page 28 · click to enlarge
Page 28

Troubleshooting – Honeywell Millivolt Valve

Window Frame Assembly Should be Removed Before Service Work

START CHECK

  • Supply line hooked up
  • Shutoff valve OPEN

NO

M M

YES

  • Lockout has engaged. Wait 60 seconds and try again.
  • For spark at electrode while depressing Piezo, 1/8" gap to pilot hood needed.
  • All wiring connections
  • Replace Piezo igniter

M

Pilot lights with Piezo igniter

NO

YES

  • For air in the lines
  • Thermopile needs min. 325 mv
  • Adjust Pilot flame height
  • All wiring connections
  • Replace thermopile
  • Thermocouple needs min. 14 mv

M

PILOT STAYS LIT

NO

M

YES

  • Valve is turned ON
  • Wall switch is not turned ON. Watch for grounded wires!
  • Thermopile needs min. 325 mv.
  • Plugged burner orifice
  • Defective Valve: Turn to Pilot; meter should read greater than 100 mv. If not, replace.

M

PILOT LIGHTS MAIN BURNER

NO

M

YES

M

SYSTEM OK

Gas Supply ON · 10004920

Page 29 of the Vermont Casting DVR33 user manual — SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION
Page 29 · click to enlarge
Page 29

Troubleshooting the Gas Control System

SIT NOVA 820 MILLIVOLT VALVE

SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION

1.Spark ignitor will not light A. Defective or misaligned Using a match, light pilot. If pilot lights, turn off electrode at pilot. pilot and push the red button again. If pilot des not light, check gap at electrode and pilot; it should be 1/8" to have a strong spark.

B. Defective ignitor (Push Button) Push Piezo Ignitor Button. Check for spark at electrode and pilot. If no spark to pilot, and elec trode wire is properly connected, replace ignitor.

2.Pilot will not stay lit after A. Defective pilot generator Check pilot flame. Must impinge on thermo carefully following lighting (thermocouple), remote wall couple/thermopile. Note: this pilot burner assem instructions. switch. bly utilizes both-a thermocouple and a thermopile. The thermocouple operates the main valve operation (On and Off). Clean and or adjust pilot for maximum flame impingement on thermopile and thermocouple.

B. Defective automatic valve Turn valve knob to “Pilot”. Maintain flow to pilot; millivolt meter should read greater than 10 mV. If the reading is okay and the pilot does not stay on, replace the gas valve. Note: An interrupter block (not supplied) must be used to conduct this test.

3.Pilot burning, no gas to A. Wall switch or wires defective Check wall switch and wires for proper connec main burner tions. Jumper wire across terminals at wall switch, if burner comes on, replace defective wall switch. If okay, jumper wires across wall switch wires at valve, if burner comes on, wires are faulty or connections are bad.

B. Thermopile may not be 1. Be sure wire connections from thermopile at generating sufficient gas valve terminals are tight and thermopile is millivoltage. fully inserted into pilot bracket. 2. One of the wall switch wires may be grounded. Remove wall switch wires from valve terminals if pilot now stays lit, trace wall switch wiring for ground. May be grounded to fireplace or gas supply. 3. Check thermopile with millivolt meter. Take reading at thermopile terminals of gas valve. Should read 250-300 millivolts (minimum 150) while holding valve knob depressed in pilot position and wall switch “Off”. Replace faulty thermopile if reading is below specified minimum.

C. Plugged burner orifice. Check burner orifices for debris and remove.

D. Defective automatic valve Turn valve knob to “On”, place wall switch to “On” operator. millivolt meter should read greater than 100 mV. If the reading is okay and the burner does not come on, replace the gas valve.

4.Frequent pilot outage A. Pilot flame may be too low Clean and/or adjust pilot flame for maximum flame problem. or blowing (high) causing the impingement on thermopile and thermocouple. pilot safety to drop out.

B. Possible blockage of the vent Check the vent terminal for blockage (recycling the terminal. flue gases)

10004920

Page 30 of the Vermont Casting DVR33 user manual — YES
Page 30 · click to enlarge
Page 30

Troubleshooting the Gas Control System

SIT 822 Valve with a Honeywell Electronic Igniter

NOTE: Remove glass before servicing. START

TURN GAS SUPPLY OFF TURN ON/OFF SWITCH TO CALL FOR HEAT

NO

CHECK: LINE VOLTAGE (120VAC)

LOW VOLTAGE TRANSFORMER (19.5 minimum VAC) ON/OFF SWITCH WIRING CONNECTIONS

POWER TO MODULE

(24V NORMAL)

UNPLUG IGNITION LEAD

YES

NO

AND CHECK SPARK

NO

APRK ACROSS IGNITOR SENSOR GAP

REPLACE MODULE

AT MODULE (24VAC normal)

YES

SPARK OK?

YES

CHECK IGNITION CABLE GROUND WIRING, CERAMIC INSULATOR AND GAP. CORRECT AS NECESSARY CHECK BOOT OF IGNITION CABLE FOR SIGNS OF MELING OR BUCKLING. TAKE PROTECTIVE ACTION TO SHIELD CABLE AND BOOT FROM EXCESSIVE TEMPERATURES.

NO

TURN GAS ON

CHECK THAT ALL MANUAL GAS VALVES ARE OPEN, SUPPLY TUBING

PILOT BURNER LIGHTS?

AND PRESSURES ARE GOOD, AND PILOT BURNER ORIFICE IS NOT BLOCKED. CHECK ELECTRICAL CONNECTIONS BETWEEN MODULE AND

YES

PILOT OEPRATOR ON GAS CONTROL. CHECK FOR 24VAC ACROSS PV-MVPV TERMIANLS ON MODULE IF

VOLTAGE IS OKAY, REPLACE GAS CONTROL IF NOT, REPLACE MODULE.

NO

SPARK STOPS WHEN

PILOT IS LIT?

CHECK CONTINUITY OF IGNITION CABLE AND GROUND WIRE. CLEAN FLAME ROD. CHECK ELECTRICAL CONNECTIONS BETWEEN FLAME ROAD & MODULE. CHECK FOR CRACKED CERAMIC FLAME ROD INSULATOR. CHECK FOR CRACKED CERAMIC FLAME ROD INSULATOR. CHECK THAT PILOT FLAME COVERS FLAME ROD AND IS STEADY BLUE ADJUST PILOT FLAME. IF PROBLEM PERSISTS, REPLACE MODULE.

YES

NO

CHECK FOR 24VAC ACROSS MV-MVPV TERMINALS IF NO

MAIN BURNER LIGHTS?

VOLTAGE, REPLACE MODULE. CHECK ELECTRICAL CONNECTIONS BETWEEN MODULE AND GAS

YES

CONTROL. IF OKAY, REPLACE GAS CONTROL, OR GAS CONTROL OPERATOR.

SYSTEM RUNS UNTIL ON/OFF SWITCH IS IN

NO

"OFF" POSITION

CHECK FOR CONTINUITY OF IGNITION CABLE AND GROUND WIRE. NOTE: IF GROUND IS POOR OR ERRATIC, SHUTDOWN MAY OCCUR OCCASIONALLY EVEN THOUGH OPERATION IS NORMAL AT THE TIME OF CHECKOUT. CHECK THAT THE PILOT FLAME COVERS FLAME ROAD AND IS STEADY

YES

TROUBLESHOOTING

AND BLUE. IF CHECKS ARE OKAY, REPLACE MODULE

ENDS

10004920

Page 31 of the Vermont Casting DVR33 user manual — Operating Instructions
Page 31 · click to enlarge
Page 31

Fuel Conversion Instructions Honeywell Gas Control Valve (Fig. 48): The Honeywell valve fitted to this unit is suitable for use with LP or Natural Gas. It is converted to the required gas application by installation of a color coded “conversion screw.” a) Using a suitable small screwdriver lift out the central regulator cap from the “Hi–Lo” knob on the valve. b) Unscrew the exposed conversion screw. c) Insert the new color coded conversion screw. Do not over-tighten the screw, it must be finger tight. d) Refit the regulator cap. e) Mount conversion label supplied with con- version screw to valve in a visible position.

For RN and RP models only:

The conversion of this appliance from one gas to another must be carried out by an authorized service provider.

1. Disconnect power to unit and shut off the gas supply. 2. Remove the glass (see “Window Frame Assembly Removal” section). 3. Carefully remove the logs and lava rock material. 4. Remove the pilot assembly from the bracket. 5. Remove the screws that are holding the burner housing assembly in place. 6. Remove the burner housing assembly. 7. Remove front and rear orifice and replace with the orifice supplied in the conversion kit. Use the orifice with the smallest hole for the front burner and the orifice with the largest hole for the rear burner.

10. Reassemble fireplace in the reverse order, except window frame assembly. Leave this off until after unit has been checked for leaks and the gas supply has been bled.
11. After bleeding gas line and checking for leaks with a soap solution, replace the front glass. Fire up the unit, check for flame impingement on logs, adjusting them if necessary. Check manifold and supply pressures against the appliance specifications.

shutter on the end burner housing must be replaced. Refer to the instructions in the specific gas conversion kit for details.

The procedure for converting from one gas to another is the same regardless of the initial gas used. The only variations are in orifice sizes and component part numbers. Your authorized service provider will ensure correct parts are used.

8. SIT Top Convertible Pilot Gently lift off pilot hood from the pilot. (Do not remove the spring clip holding the hood in place). Using a 5/32” Allen key, unscrew the exposed orifice. Insert the new orifice supplied in the kit, do not over tighten the orifice. Replace the pilot hood ensuring the index tab aligns with the notch on the hood.
Vermont Casting DVR33 — Operating Instructions diagram (page 31)
Fig. 30 · Operating Instructions

PSE Pilot Using a suitable wrench on the hexagonal body unscrew the pilot hood assembly from the pilot; do not twist the hood itself. Remove the orifice and replace it with the new orifice supplied in the kit. Refit the pilot hood assembly. Do not overtighten the pilot hood. The hood must return to its original alignment. Take care to not damage the thermocouple, thermopile, or igniter.

9. SIT 820 NOVA Gas Control Valve (Fig. 47): a) Using a Torx T20 or slotted screwdriver, remove and save three (3) pressure regulator mounting screws (A), pressure regulator tower (B), and diaphram (C). b) Ensure the rubber gasket (D) is properly positioned and install the new Hi/Lo pressure regulator to valve, using the new screws (E) supplied with the kit. Tighten screws securely. (Reference torque: 25 in.lb) c) Install the enclosed identification label (F) to the valve body where it can be easily seen.

Nova SIT820 Gas Valve CO122

Fig. 47 Nova SIT 820 gas valve conversion.

10004920

Page 32 of the Vermont Casting DVR33 user manual — Maintenance
Page 32 · click to enlarge
Page 32

Cleaning the Standing Pilot Control System

Vermont Casting DVR33 — Cleaning the Standing Pilot Control System diagram (page 32)
Fig. 31 · Cleaning the Standing Pilot Control System

The burner and control system consists of:

  • burner tube
  • gas orifice
  • pilot assembly
  • thermopile
  • millivolt gas valve Most of these components may require only an occasional checkup and cleaning and some may require adjustment. If repair is necessary, it should be performed by a qualified technician.
1. Turn off pilot light at gas valve side. 2. Let fireplace cool if it has been running. 3. Remove window frame assembly. (Refer to Window Frame Assembly Removal section) 4. Remove logs. 5. Vacuum burner compartment especially around orifice primary air openings. 6. Visually inspect pilot. Brush or blow away any dust or lint accumulation. 7. Reinstall logs. 8. Ignite pilot; refer to Lighting Instructions. 9. Reinstall window frame assembly.

Honeywell Gas Valve CO123

Fig. 48 Honeywell gas valve conversion.

Maintenance

General Maintenance

To obtain proper operation, it is imperative that the pilot and burner’s flame characteristics are steady, not lifting or floating.

Burner and Burner Compartment It is important to keep the burner and the burner compartment clean. At least once per year the logs and lava rock/ember material should be removed and the burner compartment vacuumed and wiped out. Remove and replace the logs as per the instructions in this manual.

Typically, the top 3/8” or 1/2” of the thermopile should be engulfed in the pilot flame (Fig. 45, page 25).

To adjust pilot burner (to be done by a qualified service technician):

1. Remove pilot adjustment cap. 2. Adjust pilot screw to provide properly sized flame. 3. Replace pilot adjustment cap.

Always handle the logs with care as they are fragile and may also be hot if the fireplace has been in use.

The primary air shutter is set at factory and should be adjusted, if necessary, only by a qualified service technician.

FK24/FK12 Fan Assembly The fan unit requires periodic cleaning. At least once per month in the operating season, open the lower louvre panels and wipe or vacuum the area around the fan to remove any build up of dust or lint.

Brass Trim Clean the brass trim pieces using a soft cloth lightly dampened with lemon oil. Do not use water or household cleaners on any brass components.

Contact your local representative to arrange an annual service program.

Show 4 more labels / short text on this page
Regulator Cap · Conversion Screw · Pressure Regulator Housing · 10004920
Page 33 of the Vermont Casting DVR33 user manual — Operating Instructions
Page 33 · click to enlarge
Page 33
Vermont Casting DVR33 — Operating Instructions diagram (page 33)
Fig. 32 · Operating Instructions

Vermont Castings, Majestic Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. DVR33

10004920

Page 34 of the Vermont Casting DVR33 user manual — Operating Instructions
Page 34 · click to enlarge
Page 34
Vermont Casting DVR33 — Operating Instructions diagram (page 34)
Fig. 33 · Operating Instructions

Vermont Castings, Majestic Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. DVR33

(Items marked with ‘*’ are not shown in the parts illustration.)

Ref. Description DVR33 1. Log Set (complete) 10004921 1a. Log - Front/Rear Left 10004929 (A33) 1b. Log - Rear Right 10004925 (A34) 1c. Log - Front Right 10004928 (A35) 1d. Log - Front Center 10004927 (A36) * Lava Rock 1 lb. package 10001454 * Lava Rock Burner Package 57897 2. Burner Housing Assembly, NG & LP 10004901 2a. Ceramic Tile (Single) 57803 * Orifice Burner NG and LP See the rating plate for orifice specifications

10004920

Page 35 of the Vermont Casting DVR33 user manual — DVR33 (continued) (Items marked ‘*’ are not shown in the parts illustration.)
Page 35 · click to enlarge
Page 35

DVR33 (continued) (Items marked ‘*’ are not shown in the parts illustration.)

Ref. Description DVR33

3a. Pilot Assembly SIT Top Convertible RN 10002264 3b. Pilot Assembly SIT Top Convertible RP 10002265 4a. Pilot Assembly SIT Top Convertible EN 10002387 4b. Pilot Assembly SIT Top Convertible EP 10002388 5a. Pilot Assembly PSE RN 10001741 5b. Pilot Assembly PSE RP 10001742 6. Pilot SIT Top Convertible 10002266 7. Pilot PSE (with Cable and Electrode) 10001824 * Pilot Orifice SIT NG 10002268 * Pilot Orifice SIT LP 10002269 * Pilot Orifice PSE NG 10001822 * Pilot Orifice PSE LP 10001823 8. Pilot Hood SIT Top Convertible 10002385 9. Thermocouple SIT 53373 10. Thermocouple PSE 10001825 11. Thermopile 51827 12. Ignitor Electrode with Cable, SIT RN/RP 10001297 13. Ignitor Electrode SIT EN/EP 52465 14. Cable Ignitor SIT EN/EP 10000696 15. Piezo Ignitor Honeywell Gas Valve 20000062 16. Piezo Ignitor SIT820 Gas Valve 52464 17. Pilot Tube with Fittings SIT 10001296 18. Pilot Tube with Fittings PSE 10003279 * Manifold Tube with Fittings 57318 19. Flexible Gas Line with ON/OFF Valve 20002500 20a. Honeywell Gas Control Valve, RN 10001782 20b. Honeywell Gas Control Valve, RP 10001759 21a. SIT820 Gas Control Valve RN 52677 21b. SIT820 Gas Control Valve RP 52678 22a. SIT822 Gas Control Valve EN 57884 22b. SIT822 Gas Control Valve EP 57883 23. Sensing Electrode (w/ Cable) EN/EP 57885 24. Transformer 24V EN/EP 7522409 25. Ignition Module Honeywell EN/EP 20000005 * Wire Harness Honeywell EN/EP 10001979 * Fan Assy (FK-24 option) ZA1100 26. Fan with Bracket (from FK-24 Option) 54103 * Electric Cord (from FK-24 Option) 51865 27. Fan Temperature Sensor (from FK-24 Option) 51704 28. Fan Speed Control (from FK-24 Option) 51738 29. Knob Fan Speed Control (from FK-24 Option) 51882 30. Sensor w/ Box and Wire (from FK-24 Option) 10004210 * Fan Assembly (FK-12 Option) ZA1110 31. Window Frame Assembly (no glass) 10001803

10004920

Page 36 of the Vermont Casting DVR33 user manual — DVR33 (continued) (Items marked ‘*’ are not shown in the parts illustration.)
Page 36 · click to enlarge
Page 36

DVR33 (continued) (Items marked ‘*’ are not shown in the parts illustration.)

Ref. Description DVR33

32. Window Glass with Gasket Assy 10000961 * Gasket Window Replacement 57317 33. Clamp Frame Window 54174 34. Window Trim Polished Brass with Magnets 55005 35. Top Louvre Assembly 10000292 36. Bottom Louvre Assembly 10000293 37. Hinge (Bottom Louvre) 52356 38. Wall ON/OFF Switch 51842 * ON/OFF Switch Kit 53875 39. Bracket Rear Log Assy 10004906 40. Relief Plate w/ Gasket (Burner Tray) 10004192 41. Gasket Burner Tray 10001035 42. Relief Plate w/ Gasket (Firebox Top) 10002032 * Electric Box Assy (EB-1) ZA1200

10004920

Page 37 of the Vermont Casting DVR33 user manual — Hard Wire (Direct) Hook-Up
Page 37 · click to enlarge
Page 37
Vermont Casting DVR33 — Operating Instructions diagram (page 37)
Fig. 34 · Operating Instructions

Route the 6’ (1.8 m) lead fitted to the unit to a conveniently located wall socket. Method B

1. Open lower louvre. 2. Install FK12 fan in back of unit between hearth supports (Fig. 49). 3. Secure fan on Velcro strips. 4. Power to the fan can be supplied by plugging the supply lead into a conveniently located wall socket or by using a hard-wired EB-1 connector box. 5. Be sure fan motor does not touch nearby metal.

If EB-1 receptacle box (Pt. #ZA1200) was correctly connected when the unit was installed, the fan lead can be directly plugged into the EB-1 plug socket. 5. Whether wiring directly to the fan junction box (Option A), or into EB-1 electrical receptacle box (Option B), first ensure cable is secured using box connector.

The fireplace, when installed must be electrically connected and grounded in accordance with local codes, or in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code or for USA installations, follow local codes and the National Electrical Code, ANSI/NFPA No. 70.

Vermont Casting DVR33 — Operating Instructions diagram (page 37)
Fig. 35 · Operating Instructions

Hard Wire (Direct) Hook-Up

First connect ground wire to ground stud located on the base of either box. Black wire from supply should connect to the variable speed switch. Alternate speed switch wire connects to temperature sensor. Alternate lead from sensor connects to fan. Alternate fan lead connects back to the white supply wire (Fig. 51).

Fig. 49 FK-12 Fan placement.

FK-24 Fan Assembly Fan specifications: 120 volt, 60 Hz, 0.75 Amp.

Vermont Casting DVR33 — Hard Wire (Direct) Hook-Up diagram (page 37)
Fig. 36 · Hard Wire (Direct) Hook-Up

This fan does not need regular maintenance, however periodic cleaning is required. Check the area under the control door and in front of the fan and wipe or vacuum at least once a month during the operating season.

Should this fan require servicing, the power supply must be disconnected.

The FK-24 comes with the electrical cord attached.

1. Slide fan assembly from the left side into the fireplace opening, line up mounting holes with screw studs on back of fireplace and fasten with #10-24 hex nuts. 2. Install thermal sensor on bottom of firebox using #10-24 hex nuts. 3. Option A– Place electronic fan speed control box on bottom of fireplace base, lining up mounting holes with screw studs. Fasten fan speed control box with #10-24 hex nuts. Option B– The speed control can be installed in an electrical box at normal wall switch height for convenient access. 4. Connect the power supply in one of two ways:

Fig. 50 FK-24 fan placement.

Vermont Casting DVR33 — Hard Wire (Direct) Hook-Up diagram (page 37)
Fig. 37 · Hard Wire (Direct) Hook-Up

Fig. 51 FK-24 fan wiring.

Any electrical rewiring of this fan must be completed by a qualified electrician. Turn off all power before hookup.

FK-12 Fan Assembly · 10004920

Page 38 of the Vermont Casting DVR33 user manual — Decorative Bay Windows
Page 38 · click to enlarge
Page 38

Remote Controls

Optional remote control units are available to control different functions of the appliance (only for RN/RP models).

MRC1 ON/OFF MRC2 ON/OFF and Temperature MRC3 ON/OFF and Temperature control with a digital display and a programmable 24-hour clock IMT Wall-mounted thermostat control

BURNER HOUSING

ASSEMBLY

FP1193

Fig. 52 Install ceramic refractory panels.

Ceramic Refractory Panels

Ceramic refractory panels are available to line the firebox area.

Rear Panel Support Brackets

DVR33 DVR33CR

Take care when handling the refractory panels as they are fragile until held in place and supported.

Installation (refer to Fig. 52 and Fig. 54)

FP1194

Fig. 53 Place the rear panel on rear support brackets.

1. Remove the window frame assembly 2. Remove the logs. 3. Place the lower supports for the side refractory panels on the base of the firebox. Place each support so that the slotted hole fits over the forward screw head along the edge of the base. 4. Lay the angular base panels in place on the floor of the firebox on either side of the burner housing assembly. 5. Loosely attach the top adjustable tabs to the studs located in the top of the firebox toward the front corners. 6. Place the rear refractory panel in place. Locate the ‘small brick’ edge of the panel into the two small supports on the back panel just above the rear log support. 7. Slide the side refractory panels into place to hold the rear panel secure. Adjust the top adjustable tabs to hold the side panel against the firebox wall and secure the tab. Repeat the procedure on the other side. 8. Replace the logs and window frame assembly.

Decorative Bay Windows

The original front frame/glass assembly MUST remain in place when fitting the bay window kits. The bay window kit fits over existing front glass. Bay window kits are available for model DVR33 fireplace.

1. Remove the existing louvre assembly bottom complete with the hinges. 2. Remove the louvre assembly top. 3. Assemble the Bay Window Kit according to the instructions supplied with the kit. 4. Place the 2 pieces of ceramic refractory along the base of the bay window (Fig. 54). 5. Hang the Bay Window Assembly over the existing window frame assembly. 6. Reinstall the upper louvre assembly.

aligning the horizontal mortar lines.

Do not remove the existing window frame assembly.

Show 18 more labels / short text on this page
Adjustable · tab · Adjustable tab · Side panel · Log Support · Back Panel · Model Function(s) Controlled · Side panel · Lower · Lower side support · side support · Floor refractory panel · Rear Refractory Panel · Unit Kit Model · Firebox Back · Rear Log Support · Installation · 10004920
Page 39 of the Vermont Casting DVR33 user manual — FP1195
Page 39 · click to enlarge
Page 39

Decorative Frame Trims

A selection of decorative frame trim kits are available for mounting around the outside of the appliance to enhance its visual effect on the room. Installation instructions for each decorative frame trim are included with the frame trim kit. Contact your authorized distributor for details of the trim kits and ordering information for the trim kits applicable to this model appliance.

FP1195

Fig. 54 Bay window.

Show 9 more labels / short text on this page
Louvre Assembly Top · Bay Window Frame · Ceramic Refractory · Ceramic Refractory · Spacers · Louvre Assembly Bottom · Bottom Brass Trim · Screws · 10004920
Page 40 of the Vermont Casting DVR33 user manual — IF WARRANTY SERVICE IS NEEDED…
Page 40 · click to enlarge
Page 40

LIMITED LIFETIME WARRANTY

PRODUCT COVERED BY THIS WARRANTY All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic or Northern Flame brand gas fireplaces equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner.

BASIC WARRANTY

  • Any part and/or component replaced under the provisions of this warranty is covered for six months or the remainder of the original warranty, whichever is longest.
  • This warranty is limited to the repair of or replacement of part(s) found to be defective in material or workmanship, provided that such part(s) have been subjected to normal conditions of use and service, after said defect is confirmed by the Company’s inspection.
  • The company may, at its discretion, fully discharge all obligations with respect to this warranty by refunding the wholesale price of the defective part(s)
  • Any installation, labor, construction, transportation, or other related costs/expenses arising from defective part(s), repair, replacement, or otherwise of same, will not be covered by this warranty, nor shall the Company assume responsibility for same. Further, the Company will not be responsible for any incidental, indirect, or consequential damages except as provided by law.
  • SOME STATES DO NOT ALLOW FOR THE EXCLUSION OR LIMITATIONS OF INCIDENTAL AND CONSEQUENTIAL DAMAGES OR LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOUR CIRCUMSTANCES. THIS WARRANTY GIVES YOU SPECIFIC RIGHTS AND YOU MAY HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE.
  • All other warranties-expressed or impliedwith respect to the product, its components and accessories, or any obligations/liabilities on the part of the Company are hereby expressly excluded.
  • The Company neither assumes, nor authorizes any third party to assume on its behalf, any other liabilities with respect to the sale of this Vermont Castings, Majestic product
  • The warranties as outlined within this document do not apply to chimney components or other non Vermont Castings, Majestic accessories used in conjunction with the installation of this product..
  • Damage to the unit while in transit is not covered by this warranty but is subject to claim against the common carrier. Contact the dealer from whom you purchased your fireplace/stove (do not operate the appliance as this might negate the ability to process the claim with the carrier).
  • The Company will not be responsible for: a) Down drafts or spillage caused by environmental conditions such

The Vermont Castings, Majestic Products Company (hereinafter referred to collectively as the Company) warrants that your new Vermont Castings or Majestic Gas Fireplace/Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to the following conditions and limitations.

EXTENDED LIFETIME WARRANTY

The heat exchanger, where applicable, and combustion chamber of every Vermont Castings or Majestic gas product is warranted for life against through wall perforation. All appliances equipped with an Insta-Flame Ceramic Burner have limited lifetime coverage on the ceramic burner plaque. Warrantees are made to the original owner subject to proof of purchase and the conditions and limitations listed on this Warranty Document

COMPONENT WARRANTY

CAST IRON: All external and internal cast iron parts are warranted for a period of three years.

Note: On porcelain enamel finished external parts and accessories The Company offers no Warranty on chipping of enamel surfaces. Inspect all product prior to accepting it for any damage to the enamel. The salt air environment of coastal areas or a high humidity environment can be corrosive to the porcelain enamel finish. These conditions can cause rusting of the cast iron beneath the porcelain enamel finish, which will cause the finish to flake off. Dye lot variations with replacement parts and/or accessories can occur and are not covered by warranty.

GLASS DOORS: Glass doors are covered for a period of one year. Glass doors are not warranted for breakage due to misuse or accident. Glass doors are not covered for discoloration or burned in stains due to environmental issues, or improper cleaning and maintenance.

BRASS PLATED PARTS AND ACCESSORIES: Brass parts should be cleaned with Lemon oil only. Brass cleaners cannot be used. Mortar mix and masonry cleaners may corrode the brass finish. The Company will not be responsible for, nor will it warrant any brass parts which are damaged by external chemicals or down draft conditions.

GAS VALVESGas valves are covered for a period of one year

ELECTRONIC AND MECHANICAL COMPONENTS: Electronic and mechanical components of the burner assembly are covered for one year. All steel tube burners are warranted for one year.

as near-by trees, buildings, roof tops, hills, or mountains. b) Inadequate ventilation or negative air pressure caused by

mechanical systems such as furnaces, fans, clothes dryers, etc. • This warranty is void if: a) The fireplace has been operated in atmospheres contaminated

ACCESSORIES: Unless otherwise noted all components and Vermont Castings, Majestic Products company supplied accessories are covered for a period of one year.

by chlorine, fluorine, or other damaging chemicals. b) The fireplace has been subjected to prolonged periods of

CONDITIONS AND LIMITATIONS

  • This new Vermont Castings or Majestic product must be installed by a competent, authorized, service contractor. A licensed technician, as prescribed by the local jurisdiction must perform any installation/ service work. It must be installed and operated at all times in accordance with the Installation and Operating instructions furnished with the product. Any alteration, willful abuse, accident, or misuse of the product shall nullify this warranty.
  • This warranty is non-transferable, and is made to the original owner, provided that the purchase was made through an authorized supplier of the Company.
  • The customer must pay for any Authorized Dealer in-home travel fees or service charges for in-home repair work. It is the dealers option whether the repair work will be done in the customer’s home or in the dealer’s shop.
  • If upon inspection, the damage is found to be the fault of the manufacturer, repairs will be authorized at no charge to the customer parts and/or labor.

dampness or condensation c) Any damages to the fireplace, combustion chamber, heat exchanger or other components due to water, or weather damage, which is the result of but not limited to, improper chimney/venting installation. d) Any alteration, willful abuse, accident, or misuse of the product

has occurred.

IF WARRANTY SERVICE IS NEEDED…

1. Contact your supplier. Make sure you have your warranty, your sales receipt, and the model/serial number of your Vermont Castings, Majestic product. 2) DO NOT ATTEMPT TO DO ANY SERVICE WORK YOURSELF.
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
1.Spark ignitor will not lightA. Defective or misaligned electrode at pilot.Using a match, light pilot. If pilot lights, turn off pilot and push the red button again. If pilot des not light, check gap at electrode and pilot; it should be 1/8" to have a strong spark. p.29
1.Spark ignitor will not lightB. Defective ignitor (Push Button)Push Piezo Ignitor Button. Check for spark at electrode and pilot. If no spark to pilot, and elec trode wire is properly connected, replace ignitor. p.29
2.Pilot will not stay lit after carefully following lighting instructions.A. Defective pilot generator (thermocouple), remote wall switch.Check pilot flame. Must impinge on thermo couple/thermopile. Note: this pilot burner assem bly utilizes both-a thermocouple and a thermopile. The thermocouple operates the main valve operation (On and Off). Clean and or adjust pilot for maximum flame impingement on thermopile and thermocouple. p.29
2.Pilot will not stay lit after carefully following lighting instructions.B. Defective automatic valveTurn valve knob to “Pilot”. Maintain flow to pilot; millivolt meter should read greater than 10 mV. If the reading is okay and the pilot does not stay on, replace the gas valve. Note: An interrupter block (not supplied) must be used to conduct this test. p.29
3.Pilot burning, no gas to main burnerA. Wall switch or wires defectiveCheck wall switch and wires for proper connec tions. Jumper wire across terminals at wall switch, if burner comes on, replace defective wall switch. If okay, jumper wires across wall switch wires at valve, if burner comes on, wires are faulty or connections are bad. p.29
3.Pilot burning, no gas to main burnerB. Thermopile may not be generating sufficient millivoltage.1. Be sure wire connections from thermopile at gas valve terminals are tight and thermopile is fully inserted into pilot bracket. 2. One of the wall switch wires may be grounded. Remove wall switch wires from valve terminals if pilot now stays lit, trace wall switch wiring for ground. May be grounded to fireplace or gas supply. 3. Check thermopile with millivolt meter. Take reading at thermopile terminals of gas valve. Should read 250-300 millivolts (minimum 150) while holding valve knob depressed in pilot position and wall switch “Off”. Replace faulty thermopile if reading is below specified minimum. p.29
3.Pilot burning, no gas to main burnerC. Plugged burner orifice.Check burner orifices for debris and remove. p.29
3.Pilot burning, no gas to main burnerD. Defective automatic valve operator.Turn valve knob to “On”, place wall switch to “On” millivolt meter should read greater than 100 mV. If the reading is okay and the burner does not come on, replace the gas valve. p.29
4.Frequent pilot outage problem.A. Pilot flame may be too low or blowing (high) causing the pilot safety to drop out.Clean and/or adjust pilot flame for maximum flame impingement on thermopile and thermocouple. p.29
4.Frequent pilot outage problem.B. Possible blockage of the vent terminal.Check the vent terminal for blockage (recycling the flue gases) p.29
TROUBLESHOOTING ENDS p.30

Ask about the Vermont Casting DVR33

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Vermont Casting DVR33

Be the first to ask — other owners or our team will answer.

Original document

Vermont Casting DVR33 manual PDF

40 pages·952 KB·Ventilation Hood·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…