SAFETY INFORMATION
PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard, and will void the warranty. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result, causing property damage, personal injury, or loss of life.
and Operating Manual
E
S
G
N
E
R
T
F
E
D
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
10006326 6/06 Rev. 1
,/

This gas appliance should be installed by a qualified installer in accordance with local building codes and current CSA-B149.1 Installation Codes for Gas Burning Appliances and Equipment. If the unit is being installed in a mobile home, the installation should comply with the current CAN/CSA Z 240.4 code. For U.S.A. Instal- lations, follow local codes and/or the current National Fuel Gas Code, ANSI Z223.1/NFPA 54. In the Commonwealth of Massachusetts, all gas fittings and installation of this appliance shall be done by a licensed gas fitter or licensed plumber. FOR SAFE INSTALLATION AND OPERATION PLEASE NOTE THE FOLLOWING: 1. This fireplace gives off high temperatures and should be located out of high traffic areas and away from furniture and draperies. 2. Children and adults should be alerted to the hazards of high surface temperatures of this fireplace and should stay away to avoid burns or ignition of clothing. 3. CAUTION: Due to high glass surface temperature, chil- dren should be carefully supervised when in the same room as fireplace. 4. Under no circumstances should this fireplace be modified. Parts removed for servicing should be replaced prior to operating this fireplace again. 5. Installation and any repairs to this fireplace must be per- formed by a qualified installer, service agency or gas sup- plier. A professional service person should be contacted to inspect this fireplace annually. Make it a practice to have all of your gas fireplaces checked annually. More frequent cleaning may be required due to excess lint and dust from carpeting, bedding material, etc. 6. Control compartments, burners and air passages in this fireplace should be kept clean and free of dust and lint. Make sure the gas valve and pilot light are turned off be- fore you attempt to clean this fireplace. 7. The venting system (chimney) of this fireplace should be checked at least once a year, and if needed, your venting system should be cleaned. 8. Keep the area around your fireplace clear of combustible materials, gasoline and other flammable vapor and liquids. This fireplace should not be used as a drying rack for clothing, nor should Christmas stockings or decorations be hung on or around the fireplace. 9. Under no circumstances should any solid fuels (wood, coal, paper or cardboard, etc.) be used in this fireplace. 10. The flow of combustion and ventilation air must not be obstructed in any way. 11. When the fireplace is installed directly on carpeting, vinyl tile, or any combustible material other than wood, it must be installed on a metal or wood panel extending the full width and depth of the fireplace. 12. This fireplace requires adequate ventilation and combus- tion air to operate properly. 13. This fireplace must not be connected to a chimney flue serving a separate solid fuel-burning fireplace. 14. When the fireplace is not in use, it is recommended the gas valve be left in the “OFF” position.
This appliance may be installed in an aftermarket, per- manently located, manufactured home, or mobile home where not prohibited by local codes. This appliance is only for use with type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
IMPORTANT: PLEASE REVIEW THE FOLLOWING CAREFULLY Remove any plastic from trim parts before turning the fireplace ON. It is normal for fireplaces fabricated of steel to give off some expansion and/or contraction noises during the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or car engine. It is not unusual for your gas fireplace to give off some odor the first time it is burned. This is due to the curing of the paint and any undetected oil from the manufacturing process. Please ensure that your room is well ventilated - open all windows. It is recommended that you burn your fireplace for at least ten (10) hours the first time you use it. If the optional fan kit has been installed, place the fan switch in the “OFF” position during this time.
Proposition 65 Warning: Fuels used in gas, wood- burning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth de- fects and other reproductive harm. California Health & Safety Code Sec. 25249.6
B
Y
A A
Y
Y
Z
LU584-2
Fig. 1 Locating your gas fireplace
A Wall Location (Fig. 1) Y (Minimum distance between a glass panel and a parallel wall) = 3’ (914mm) Z (Minimum distance between edge of a glass panel and an adjacent wall) = 3” (76mm) B Island Location (Fig. 1) X (Maximum length of horizontal venting) = 20’ (6.1m)
Refer to the venting section in this manual for specific dimen- sions.
10006326


Fig. 2a Fireplace specifications—360DVS2

10006326


Fig. 2b Fireplace specifications—360DVS3/ 360DDVSL/ 360DVSR

10006326


Fig. 3a Fireplace framing dimensions—360DVS2

10006326


Fig. 3b Fireplace framing dimensions—360DVS3/ 360DVSL/ 360DVSR

10006326

Appliance Top 0” (0 mm) to standoff Bottom 0” (0 mm) Vent End 1/2” (13 mm) to rear panel Nonvent End (DVS2) 0” (0 mm) Venting Concentric sections of DV Vent: Top, bottom & sides 1” (25 mm) Nonconcentric sections of DV Vent: Side and bottom 1” (25 mm) Top 2” (51 mm)
F G H I
CFM197
Mantels
K
M
Side of Combustion Chamber
The height at which a combustible mantel is fitted above the fireplace is dependent on the depth of the mantel. This also applies to the distance between the mantel leg (if so fitted) and the fireplace. For correct mounting height and width, refer to Fig. 4a and 4b and the Mantel Chart below.
The fitting of a bay window trim kit does not affect the distances and reference points referred to in the dia- gram and chart.
Noncombustible mantels and legs may be installed at any height and width around the appliance.
When using paint or lacquer to finish the mantel, such paint or lacquer must be heat resistant to prevent dis- coloration.
Mantel Mantel Leg From Side Ref. Leg Depth Ref. of Comb. Opening F 10” (254 mm) K 11¹⁄₂” (292 mm) G 8” (203 mm) L 9¹⁄₂” (241 mm) H 6” (152 mm) M 7¹⁄₂” (191 mm) I 4” (102 mm) N 5¹⁄₂” (140 mm) J 2” (51 mm) O 3¹⁄₂” (89 mm)
Fig. 4b Combustible mantel leg minimum installation.
A hearth is not mandatory; however, for aesthetic purposes, we recommend installing a noncombustible hearth that projects out 12” (305mm) or more from the front of the fireplace.
Cold climate installation recommendation:
When installing this unit against a noninsu- lated exterior wall or chase, it is mandatory the outer walls be insulated to conform to applicable insulation codes.
Fig. 4a Combustible mantel minimum installation.

1. Choose the unit location. 2. Place the unit into position and secure it to the floor with 1¹⁄₂” (38mm) screws or nails. Holes to secure the unit to the floor are located behind the access door grille on the left and right sides of the unit. 3. Frame in the fireplace with a header across the top. It is important to allow for the finished wall face when setting the depth of the frame. 4. Drywall (sheetrock) or wood material may be placed with a zero clearance to the top edges of the appli- ance when finishing walls above sides of the appli- ance with glass windows. NOTE: Attach wall finish- ing to constructed frame, not the appliance. 5. On 360DVSL and 360DVSR, drywall, wood, or wood molding may be placed with zero clearance to the rear wall of the unit, along the vertical edge formed by the standoffs, to intersection of the rear wall, to the side wall having the small glass window. NOTE: Attach wall finishing to constructed frame, not the appliance.
Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4,500 feet (1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA, installations must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction.
In Canada, please consult provincial and/or local authorities having jurisdiction for installations above 4,500 feet (1,370 m).
ANSI Z21.88-2005 / CSA 2.33-2005
Vented Gas Fireplace Heaters
Gas Line Installation
Noncombustible materials such as brick or tile may be extended over the edges of the face of the appliance. DO NOT cover any vent or grille panels.
When purging the gas lines, the window frame assembly must be removed.
If a Trim Kit is going to be installed on the fireplace, the brick or tile will have to be installed flush with the edges of the appliance.
The gas pipeline can be brought in through the vent end of the fireplace as well as the bottom. Knockouts (to allow gas pipe installation and testing any gas con- nection) are provided on the bottom behind the valve. It is most convenient to bring the gas line in from the vent end of the valve, as this allows fan installation or removal without disconnecting the gas line.
The gas line connection can be made with properly tinned 3/8” copper tubing, 3/8” rigid pipe, or an ap- proved flex connector. Since some municipalities have additional local codes, it is always best to consult your local authority and the CSA-B149.1 installation codes.
For USA installations, consult the current National Fuel Gas Code, ANSI Z223.1/NFPA 54.
Always check for gas leaks with a mild soap and water solution. Do not use an open flame for leak testing.

1/2” Gas Supply 1/2” NPT X 1/2” Flare Shut-Off Valve
Fig. 5 Gas shutoff valve and flex connector.
10006326

The gas control is equipped with a captured-screw type pressure test point, therefore it is not necessary to pro- vide a 1/8” test point upstream of the control. When using copper or flex connector, use only ap- proved fittings. Always provide a union when using black iron pipe so that the gas line can be easily discon- nected for burner or fan servicing. Refer to the gas specification for pressure details and ratings.
Isolate or disconnect this or any other gas appliance control from the gas line when pressure testing.
DO NOT subject the fireplace valve to test pressures exceeding 1/2 psi.
EB-1 Electrical box Depend- ing on the specific model, this box may be installed on either side of the appliance. FP1428
Fig. 6 EB-1 attachment.
The fireplace, when installed, must be electrically connected and grounded in ac- cordance with local codes; in the absence of local codes, use the current CSA C22.1
Do not wire the remote ON/OFF wall switch for this gas appliance into a 120V power supply.
Canadian Electrical Code.
For USA installations, follow the local codes and National Electrical Code ANSI/ NFPA No. 70.
It is strongly suggested the wiring of the EB-1 Electrical Junction Box be carried out by a licensed electrician.
Ensure power to the supply line has been disconnected before commencing with this procedure.
The EB-1 electrical junction box has been supplied standard on this model to allow for easy connection of the optional fan kits. (Fig. 6)
To connect the EB-1 box to the house electrical supply follow the steps below.
1. Remove the front cover of the EB-1 box. 2. Remove the plug socket assembly from the EB-1 box. 3. Feed the supply line in from the out through the elec- trical knockout. 4. Connect the ground wire of the supply line to the green screw of the socket assembly. 5. Connect the white wire of the power line to the chrome screw of the socket assembly. 6. Connect the black wire of the power supply line to the brass screw (polarized) of the socket assembly. 7. Refit the socket assembly back into the electrical box and replace the cover plate. 8. The EB-1 electrical junction box is now ready to sup- ply power to the FK12 or FK24 fan kit, if used.
TP
TH
Fig. 7 Remote switch wiring diagram for R models.
The remote switch can be installed on the front or the side of the access door. Simply mount the switch to the bracket provided and screw the bracket to either side of the frame, lining up the screws with the prepunched holes. (Fig. 8)

Fig. 8 Alternate switch location.
This appliance is shipped as a rear vent unit. If the installation layout requires the unit to be a top vent con- figuration, the appliance can be converted by following the steps below.
Fig. 9 Remove screws from outer collar adapter.
When removing and refitting the plates and adapter, be sure the associated gasket is undamaged and refitted as required.
1. Remove the ten (10) screws securing the outer col- lar adapter to the fireplace body. (Fig. 9) 2. Set the collar aside, complete with the gasket. NOTE: Do not damage the gasket, as the adapter and gasket must be refitted. 3. Remove the insulation material (exposed in Step 2) from the top of the unit. (Fig. 10) This material can be discarded; however, if the unit is converted back to rear-vent, a new piece of insulation material approved by CFM Corporation must be used for this purpose. NOTE: When converting appliance to top vent, ensure the insulation material referred to in step 3 is completely removed. 4. Remove the 4 screws securing the flue cover plate to the top of the intake box and remove the cover and gasket. (Fig. 11) 5. Remove 4 screws securing the flue pipe to back of the intake box and remove pipe and gasket. (Fig. 11) 6. Secure the plate and gasket removed in step 4 over the flue opening in the back of the intake box. En- sure the gasket is in place and undamaged. 7. Install the flue pipe and gasket removed in step 5 over the flue opening in the top of the intake box. 8. Refit the outer collar adapter and gasket to the unit with the round collar on the top. Secure the adapter with the 10 screws removed in step 1.
Fig. 11 Flue pipe removal.

This appliance may be fitted with a Honeywell ignition module.
Installation of the remote ON/OFF starter switch on electronic ignition units (Fig. 12):
1. Thread the wiring through the holes on the side panels of the appliance. Take care not to cut the wire or insulation on metal edges. Route the wire to a conveniently located receptacle box. 2. Attach the wire to the ON/OFF switch and install the switch into the receptacle box. 3. Connect the white wire from the wall switch to the black wire from the transformer, using an approved wire nut. Connect the black wire from the wall switch to the black wire running from the #6 position of the ignition module, also using an approved wire nut.
HONEYWELL IGNITION MODULE
MV MV/VP PV GRD 24V SENSE SPARK
ORANGE
ORANGE
LO
HI
NOVA SIT 822 VALVE
BLUE
WHITE
POWER CORD W/FEMALE SPADE
120 VAC RTN
24 VAC HOT
BLACK
WHITE
BLACK
OFF
WHITE
BLACK
YELLOW
GREEN
24 VAC RET
120 VAC HOT
40VA TRANSFORMER
WALL SWITCH
BLACK WHITE
Fig. 12 Honeywell ignition module.
garden shed, fencing, deck or utility building within 24” (610mm) from the front of the termination hood.
Your fireplace is approved to be vented either through the side wall, or vertically through the roof.
Do not locate the termination hood where excessive snow or ice buildup may occur. Be sure to check the vent termination area after snow falls; clear it to prevent accidental blockage of the venting system. When using a snow blower, make sure snow is not directed toward the vent termination area. Location of Vent Termination
It is imperative the vent termination be located observ- ing minimum clearances as shown on the following page.
There must not be any obstruction such as bushes,
10006326

Fig. 13 Vent termination clearances.
10006326


Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors.
C = Maximum depth of 48" (1219mm) for recessed location. D = Minimum width for back wall of a recessed location. Combustible 38"(965mm) Noncombustible 24"(610mm)
E = Clearance from corner in recessed location. Combustible 6"(152mm) Noncombustible 2"(50mm)
Fig. 14 Termination clearances.
Canadian Installations: Venting system must be installed in accordance with the current CSA-B149.1 installation code. USA Installations:
To join the twist lock pipes together, align the beads of the male end with the grooves of the female end. While bringing the pipes together, twist the pipe until the flange on the female end contacts the external flange on the male end. It is recommended that you secure the joints with three (3) sheet metal screws; however, this is not mandatory with twist lock pipe.
The venting system must conform with local codes and/ or current National Fuel Gas Code ANSI Z223.1/NFPA 54.
Only venting components manufactured by CFM Corpo- ration can be used in Direct Vent systems.

When using twist-lock pipe, it is not necessary to use sealant on the joints. The only areas of the venting system that need to be sealed with high-temperature silicone sealant are the collars on the fireplace and ter- mination, and sliding joints of telescopic vent sections used in the system.
Fig. 15 Twist lock pipe joints.
10006326

Rear Wall Application
The vent chart should be read in conjunction with the following vent installation instructions to determine the relationship of the vertical and horizontal dimensions of the vent system.
1. Determine the height of the center of the horizontal vent pipe exiting through the outer wall. Using this dimension on the Sidewall Vent Graph bellow, locate the point intersecting with slanted graph line. 2. From the point of this intersection, draw a vertical line to the bottom of the graph. 3. Select the indicated dimension, and position the fireplace in accordance with same. Example A: If vertical dimension from floor of the fireplace is 11’ (3.4 m), horizontal run to the face of outer wall must not exceed 14’ (4.3 m). Example B: If vertical dimension from floor of the unit is 7’ (2.14 m), horizontal run to the face of outer wall must not exceed 8¹⁄₂’ (2.6 m).
Max. 20” (508mm)
Vertical dimension from floor of the unit to center of the horizontal vent pipe
Fig. 17 Rear vent application.
Locate and cut vent opening in the rear wall.
Combustible walls: Cut a rectangular hole measuring 10³⁄₈” H x 9³⁄₈” W (265 x 240 mm) through the exterior wall and frame. Frame in the opening per Figure 18.
Noncombustible walls: Cut a round hole measuring 7¹⁄₂” (190 mm) diameter through the exterior wall and frame. (Fig. 18) STEP 2
For combustible walls: Measure wall thickness and cut zero clearance sleeve parts to proper length. Max. length is 12” (305 mm). Assemble sleeve to its maximum opening of 10³⁄₈” x 9³⁄₈” (265 x 240 mm), and attach to firestop with #8 sheetmetal screws (supplied). Install firestop assembly. (Fig. 19)
3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Horizontal dimension from outside of the wall
to the center of the fireplace vent flange Sidewall vent graph showing the relationship between vertical and
horizontal dimensions for a Direct Vent flue system.
Fig. 16 Sidewall vent graph.
Step 1 · DV Graph · 10006326


Guide vent through the vent hole as you place the appli- ance in its installed position. Guide the 4” (102 mm) and 7” (178 mm) collars of the vent termina- tion into the outer ends of the venting.
Do not force the termination. If the vent pipes do not align with the termination, remove and realign the vent- ing at the appliance flue collars.
Attach the termination to the wall as outlined in the instruction sheet supplied with the termination.
Fig. 19 Adjustable zero clearance sleeve.
Measure the horizontal length requirement for the vent- ing including a 2” (51 mm) overlap, i.e. from the elbow to the outside wall face plus 2” (51 mm), or the distance required if installing a second 90˚ elbow. (Fig. 20) STEP 4

Install the 4” (102 mm) vent to the appliance collar and secure with three (3) sheetmetal screws. Install the 7” (178 mm) vent pipe to the appliance collar and secure with three (3) sheetmetal screws. It is not neces- sary to seal this connection.
It is critical there be no downward slope away from the appliance when connecting the vent or elbow.
Fig. 20 Maximum three (3) 90° elbows per installation.
10006326

Max. 20” (508mm)
Max. 36” (914mm)
Elbow 1 = 90° Elbow 2 = 45° Elbow 3 = 45° Elbow 4 = 90° Total angular variation = 270°
1 + 2 + 3 + 4 = 270°
Fig. 21 Maximum horizontal run w/no rise.
FP1438 Fig. 23 Maximum elbow usage.
STEP 1

Locate and cut vent opening in the side wall. It may be necessary to first position the fireplace and measure to obtain the hole location. Depending on whether the wall is combustible or noncombustible, cut the opening to size per Figure 24.
Combustible walls: Cut a rectangular hole measuring 9³⁄₈” H x 9³⁄₈” W (240 x 240mm) through the exterior wall and frame. Frame in the opening per Figure 24.
Noncombustible walls: Cut a round hole measuring 7¹⁄₂” (190 mm) diameter through the exterior wall and frame. (Fig. 24) STEP 2
For combustible walls: Measure wall thickness and cut zero clearance sleeve parts to proper length. Max. length is 12” (305mm). Assemble the sleeve and attach it to the firestop with #8 sheet metal screws (supplied). Install the firestop assembly. (Fig. 25)
Zero clearance sleeve is required only for combustible walls.
Fig. 22 Horizontal run reduction.
10006326


Apply a bead of silicone to the inner and outer flue collars of the fireplace and using appropriate length of pipe section(s) attach to fireplace with three (3) screws. Follow with the installation of the inner and outer elbow, again secure joints as described in “Connecting Vent Pipes” section. STEP 5
Measure the horizontal length requirement including a 2” (51 mm) overlap, i.e. from the elbow to the outside wall face plus 2” (51 mm) (or the distance required if installing a second 90° elbow. (Fig. 27)

Fig. 25 Adjustable zero clearance sleeve.
Place fireplace into position. (Fig. 26) Measure the verti- cal height (X) required from the base of the flue collars to the center of the wall opening.
Fig. 27 Horizontal length requirement.

Use appropriate length of pipe section—telescopic or fixed—and install. The 20” (508 mm) section of pipe which goes through the wall is packaged with the 7DVSK starter kit, and can be cut to suit if necessary.
Seal vent pipe and firestop gaps with high temperature sealant to restrict cold air being drawn in around the fireplace. STEP 7
Apply high temperature sealant to 4” (102 mm) and 7” (178 mm) collars, or to the termination 1” (25 mm) away from the crimped end. Guide 4” and 7” collars of vent terminations into respective vent pipes. Double check vent pipes to see that they overlap the collars by
Fig. 26 Vertical height requirement.
10006326

2” (51 mm). Secure termination to the wall with screws provided, and caulk around the wall plate to weather- proof.
Zero Clearance Sleeve (if required)
One alternative to screwing the termination directly to the wallis the use of expanding plugs or an approved exterior construction adhesive.
Min. 4” (102mm) Clearance
Or, you may attach the termination with screws through the inner body into the 4” (102 mm) vent pipe; however, for this method, you must extend the 4” (102mm) pipe approximately 6” (153 mm) beyond the outer face of the wall.
Support the horizontal pipes with metal pipe straps every 36” (914mm).
When it is not possible to meet required vent terminal clearances of 12” (305 mm) above grade level, we rec- ommend using a starter kit. It allows installation depth down to 7” (178 mm) below grade level. Measure 7” (178 mm) from the center of the horizontal vent pipe as it penetrates through the wall.
Do not backfill around the snorkel. A clear- ance of at least 4” (102mm) must be main- tained between the snorkel and the soil.
If the foundation is recessed, use recess brackets (not supplied) for securing lower portion of the snorkel. Fas- ten brackets to wall first, then secure to snorkel with self drilling #8 x 1/2 sheetmetal screws. It will be necessary to extend vent pipes out as far as protruding wall face. (Fig. 29)
If installing a snorkel, a minimum 24” (610 mm) vertical rise is necessary. The maximum horizontal run with 24” (610 mm) vertical pipe is 36” (914mm). The measurement is taken from the collar of the fireplace (or transition elbow) to the face of exterior wall. See sidewall vent graph, Page 15, for extended horizontal runs if the vertical exceeds 24” (610 mm).

1. Establish vent hole through the wall. (Fig. 24) 2. Remove soil to depth of about 16” (406 mm) below base of snorkel. Install window well (not supplied). Refill hole with 12” (305 mm) of coarse gravel, leav- ing a clearance of about 4” (102 mm) below snorkel. (Fig. 28) 3. Install vent system. 4. Ensure a watertight seal is made around the vent pipe coming through the wall. 5. Apply high-temperature sealant caulking (supplied) around 4 in. and 7 in. snorkel collars. 6. Slide snorkel into vent pipes and secure to wall. 7. Level the soil so as to maintain a 4” (102 mm) clear- ance below snorkel. (Fig. 29)
Fig. 29 Snorkel installation / recessed foundation.


This Gas Fireplace has been approved for: • Vertical installations up to 40’ (12 m) in height. Up to a 10’ (3 m) horizontal vent run can be installed within the vent system using a maximum of two 90° elbows. (Fig. 30)
1 + 2 + 3 + 4 = 270°

FP1444 Fig. 31 Maximum elbow usage.

Fig. 32 Maximum termination to roof clearance.
10006326

If there is a room above ceiling level, a firestop spacer must be installed on both the bottom and the top sides of the ceiling joists. (Fig. 35) If an attic is above ceiling level, a 7DVAIS (Attic Insulation Shield) must be installed.
1. Locate your fireplace. 2. Plumb to center of the (4”) flue collar from ceiling above and mark position. 3. Cut an opening equal to 9³⁄₈” x 9³⁄₈” (240 x 240mm). 4. Proceed to plumb for additional openings through the roof. In all cases, the opening must provide a minimum of 1” (25 mm) clearance to the vent pipe, i.e., the hole must be at least 9³⁄₈” x 9³⁄₈” (240 x 240mm). 5. Place fireplace into position. 6. Place firestop(s) #7DVFS or Attic Insulation Shield #7DVAIS into position and secure. (Fig. 35) 7. Install roof support (Fig. 33) and roof flashing making sure upper flange is below the shingles. (Fig. 34) 8. Install appropriate pipe sections until the venting is above the flashing. (Fig. 34) 9. Install storm collar and seal around the pipe. 10. Add additional vent lengths for proper height. (Fig. 32) 11. Apply high temperature sealant to 4” and 7” collars of vertical vent termination and install.


Fig. 35 Firestop and attic insulation shield.
Fig. 33 Chimney support.

Fig. 34 Roof flashing.
10006326

7TDVRVT Through-the-Wall Rear Vent Termination
Starter Kit Model 7TDVSK - Sidewall Starter Kit Model 7TDVSKV - Vertical Venting for 7TDVSKV-A: order 1/12 to 6/12 roof pitch for 7TDVSKV-B: order 7/12 to 12/12 roof pitch for 7TDVSKV-F: order flat roof Starter Kit Model 7TDVSKS - Snorkel Kit Snorkel Termination - 7TDVSNORK for Below Grade Installation
45˚ Elbow 7TDVT45 for Rear Vent to Vertical Vent or Vertical/Horizontal Offsets 90˚ Transition Elbow 7TDVRT90 for Rear Vent to Vertical Vent 90° Elbow 7TDV90 Vertical/Horizontal Offset
Pipe Sections for vertical or horizontal venting: Model 7TDVP8” 4 per box Model 7TDVP12” 4 per box Model 7TDVP24” 4 per box Model 7TDVP36” Model 7TDVP48”
Firestop Spacer Model 7DVFS
Attic Insulation Shield Model 7DVAIS
Vertical/ Horizontal Combination Offset Support Model 7DVCS
10006326

7. To reinstall the window frame assembly reverse this procedure. Front Window Frame Assembly 1. Remove the top and bottom louvre assembly. 2. Remove the lower window trim (held in place with magnets). 3. Remove both lower retaining screws. Access to these screws is gained through the holes along the lower edge of the frame behind the trim. (Fig. 38) 4. Tilt lower edge of frame out slightly and lift window frame assembly up and away from the fireplace. 5. To reinstall the window frame assembly reverse the process.
Only glass approved by CFM Corporation should be used on this fireplace.
Pull Clamp Hook Push Clamp Han-
Fig. 37 Window frame assembly removal.
Fig. 36 Remove louvre assembly top.
Side Window Frame Assemblies 1. Shut off the gas supply. 2. Allow the fireplace to cool if it has been in operation. 3. Remove the top louvre assembly. 4. Lower the bottom louvre assembly. 5. Release the two clamps along lower edge of the frame by pulling down on clamp handles. (Fig. 37) 6. Tilt lower edge of frame out slightly and lift window frame assembly up and away from the fireplace.
Location of Lower Retaining Screws
Fig. 38 Retaining screw.

Log Installation
It is necessary to periodically clean glass. During start- up, condensation, which is normal, forms on the inside of the glass. This condensation causes lint, dust and other airborne particles to cling to glass surface.
Refer to Figures 40 and 41 for log location and align- ment.
Because of the log stack design, these instructions can be followed from either side of the fireplace. To follow these instructions, identify the logs by the number cast into the underside.
Also initial paint curing may deposit a slight film on the glass. It is therefore recommended glass be cleaned two or three times with a non-ammonia based house- hold cleaner and warm water. The use of fireplace glass cleaner is recommended within the first few weeks of operation.
For correct operation of the fireplace, the logs must be correctly placed in the sequence described below:
After the initial cleaning process the glass should be cleaned two or three times during each operating sea- son depending on the environment in the house.
Handle and dispose of plastic bags in which logs were shipped in a safe manner. As with all plastics, they are not toys and should be kept away from infants. 2. Remove both sides of the window frame assembly (where applicable). 3. Place the log rear (B120) on the grate. The square hole located on the underside of the log is to be placed over the center of the grate. The inner end of the log ensures that the bottom hole is located on the pin of the support. 4. Place the log front left (B121) on the grate. The square hole located on the underside of the log is to place over the corner leg of the grate. The inner end of the log ensures the bottom holes are located on the pin of the support. 5. Place the log front right (B122). Once more, the square hole fits over the corner leg of the grate. The inner end of this log maintains a recess on the underside, which locates over the knob on the top of the log front left (B121) to secure the inner end in place. 6. Place the log rear left (B123). The bottom back of the log rests on the grate. The notch at the back of the log locates over the knob on the top of the log rear (B120). The bottom of the log rests on top of the log front left (B121). 7. Place the log bottom left (B124). The log maintains a step on the outer end, which rests against the prong of the grate. The alternate end rests on the side floor refractory panel. 8. Place the log rear right (B125). The log maintains a hole on the underside, which rests over the knob on the top of the log rear (B120). The bottom of the log rests against the side floor refractory panel, and the side rests against the last prong of the grate. 9. Place the log center (B126). The log maintains a hole on the underside, which rests over the knob on the top of the log front right (B122). The alternate end rests against the side floor refractory panel and positions between the two (2) prongs of the grate.
Clean the glass after the first two weeks of operation.
Do not clean the glass when hot.
Do not use an abrasive cleaner.
Do not strike or slam the glass.
The vertical refractory panels are installed in the unit prior to shipment. For assembly procedures, refer to Figure 39.
Handle the refractory material carefully, the panels are fragile.
with two (2) end vertical panels, as shown in Figure 39. 360DVSL and 360DVSR units are each fitted with one end vertical panel and two side vertical panel. The 360DVS3 has only one end vertical panel.
Vertical Panels in Place When Shipped
Floor Panels Placed During Installation
Fig. 39 Ceramic panel installation.
10006326

B120
B126 B125

B121
LG320
Fig. 40 360DVS log placement.
B123

B126 B125
LG321
Fig. 41 360DVS log placement.
Flame & Temperature Adjustment
Your log set contains Ember Material and two types of Lava Rocks. Set these materials in place after the logs have been installed. Ember Material (Pt. #51915)
For units equipped with ‘HI/LO’ valves the flame adjust- ment is accomplished by rotating the ‘HI/LO’ adjustment knob located near the center of the gas control valve. (Fig. 42 and Fig. 43)
Remove ember material from the bag and separate it into small pieces, then scatter it over burner tiles in a random fashion. Do not pack down ember material; leave it in a ‘fluffy’ state. Lava Rock (Pt. #10001454)
HI
to decrease flame height
to increase flame height
Remove lav rock material from packaging and spread it over ceramic floor panels outside log stack. Do not place this lava rock material on burner tiles.
Fig. 42 Flame adjustment knob for Honeywell valve.

3/8” - 1/2” (10 - 13mm)
to decrease flame height
to increase flame height
Fig. 43 Flame adjustment knob for SIT valve.
Flame Characteristics
Fig. 45 Correct pilot flame appearance.
It is important to periodically perform a visual check of the pilot and burner flames. Compare them to the pictorials illustrated below. (Figs. 45 & 46) If the flame patterns appear abnormal, contact a qualified service provider for service and adjustment.


Fig. 46 Correct log flame appearance.
Turn counterclockwise · Turn clockwise · 10006326

Burner and Burner Compartment
To obtain proper operation, it is imperative that the pilot and burner’s flame characteristics are steady, not lifting or floating.
It is important to keep the burner and the burner com- partment clean. At least once per year remove the logs and lava rock/ember material. Vacuum and wipe out the burner compartment. Remove and refit the logs per the instructions in this manual.
Typically, the top 3/8 – 1/2” (10 – 13 mm) of the thermo- pile should be engulfed in the pilot flame. (Page 26, Fig. 46)
Always handle the logs with care as they are fragile and may also be hot if the fire- place has been in use. FK24/FK12 Fan Assembly
To adjust pilot burner (to be done by a qualified service technician):
The fan unit requires periodic cleaning. At least once per month in the operating season, open the lower lou- vre panels and wipe or vacuum the area around the fan to remove any build up of dust or lint. Brass Trim
The primary air shutter is set at factory and should be adjusted, if necessary, only by a qualified service tech- nician.
Clean the brass trim pieces using a soft cloth lightly dampened with lemon oil. Do not use water or house- hold cleaners on any brass components.
The Electronic Ignition burner/control system consists of:
The process for taking care of Electronic Ignition units is identical to that for taking care of Standing Pilot models.
Most of these components may require only an occa- sional checkup and cleaning and some may require ad- justment. If repair is necessary, it should be performed by a qualified technician.
10006326


CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. 360DVS Series
10006326

360DVS Series (Items marked ‘*’ are not shown in the parts illustration) Ref. Description 360DVS2 360DVS3 360DVSL 360DVSR 1. Log Set (complete) 10006350 1a. Log - Rear (B120) 10006315 1b. Log - Front Left (B121) 10006316 1c. Log - Front Right (B122) 10006317 1d. Log - Rear Left (B123) 10006318 1e. Log - Bottom Left (B124) 10006319 1f. Log - Rear Right (B125) 10006320 1g. Log - Center Right (B126) 10006321 2. Grate Assembly 10006014 3a. Burner Housing Assembly, Nat. 10006148 3b. Burner Housing Assembly, Prop. 10006299 * Ceramic Burner Tile 10002165 * Orifice/s, Main burner (Nat.) Refer to the rating plate for specific orifice information * Orifice/s, Main Burner (Prop.) Refer to the rating plate for specific orifice information 4a. Pilot assembly PSE (Nat.) 10001741 4b. Pilot assembly PSE (Prop.) 10001742 5a. Pilot assembly SIT Top Conv. (Nat.) 10002264 5b. Pilot assembly SIT Top Conv. (Prop.) 10002265 6. Pilot, PSE (with cable & electrode) 10001824 7. Pilot SIT Top Convertible 10002266 8. Pilot Hood, SIT Top Convertible 10002385 * Orifice, Pilot PSE (Nat.) 10001822 * Orifice, Pilot PSE (Prop.) 10001823 * Orifice, Pilot SIT Top convertible (Nat.) 10002268 * Orifice, Pilot SIT Top conv. (Prop.) 10002269 * Pilot tube & fittings (Top convertible) 10001296 * Manifold tube & fittings 10002492 * Flexible Gas Line (18”) with fittings 20002500 9. Thermocouple, PSE 10001828 10. Thermocouple, SIT Top Convertible 53373 11. Thermopile 51827 12. Ignitor electrode (with cable), SIT 10001297 13. Ignitor (Piezo), SIT 820 valve 52464 14. Ignitor (Piezo), Honeywell Valve 20000062 15a. Valve, SIT 820 (Nat.) 52677 15b. Valve, SIT 820 (Prop.) 52678 16a. Valve, Honeywell (Nat.) 10001782 16b. Valve, Honeywell (Prop.) 10001759 17. Fan & Bracket FK12 (optional) ZA1110 18. Fan & Bracket FK24 (optional) 54103 * Temperature Sensor (optional) 51704 * Fan Speed Control (optional) 51738 * Fan Speed Control Knob (optional) 51882 * Electric Cord 51865 19. Remote ON/OFF switch (RN/RP models) 51842 * Wiring Harness (remote switch) 55923 * Remote ON/OFF Switch Kit (incls. bracket) 53875 20. Louvre Assembly, side top. 10000039
10006326

Ref. Description 360DVS2 360DVS3 360DVSL 360DVSR 360DVS Series (continued) (Items marked ‘*’ are not shown in the parts illustration)
21. Louvre Assembly, side bottom 10000040 22. Louvre Assembly, end top N/A 10002411 10002411 10002411 23. Louvre Assembly, end bottom N/A 10002412 10002412 10002412 24. Hinge, lower louvre assemblies 52356 25. Trim Window Top/Bottom w/Magnets PB 57483 26. Trim Window Top/Bottom w/Magnets PB n/a 10006197 10006197 10006197 * Window Frame Assembly, side 10002483 * Window Frame Assembly, end N/A 10002484 10002484 10002484 * Window Glass (complete with gasket), side 10002533 * Window Glass (complete with gasket), end N/A 10002534 10002534 10002534 * Gasket Kit (glass replacement, 1x11’ length) 57317 27. Window Frame Clamp 54174 28. Refractory Lining (vertical end walls) 10006254 29. Refractory Lining (vertical side wall) N/A N/A 10006285 10006285 30. CR Bottom Kit w/out Rear 10006257 * Air Inlet Cover Plate Assembly 10006174 * Air Inlet Cover Plate Gasket 10006171 10006171 10006174 10006171 * Flue Pipe Plate Assembly 10002554 * FluePipe Plate Gasket 10002237 10002237 10002237 1000223 * Flue Cover Plate 10002298 * Flue Cover Plate Gasket 10002233 * Relief Plate (with gasket) 10002429 * Deflector, Cabinet Top Short N/A 10002260 10002260 10002260 * Corner Post (left) N/A 10006190 10006190 10006190 * Corner Post (right) N/A 10006191 10006191 10006191 * Corner Post Mounting Bracket N/A 10006195 10006195 10006195 * Deflector Cabinet Top Long 54364 31a. Pilot Assembly SIT Top Convertible EN 10002387 31b. Pilot Assembly SIT Top Convertible EP 10002388 32. Ignitor Electrode SIT EN/EP 52465 33. Cable Ignitor SIT EN/EP 10000696 34a. SIT822 Gas Control Valve EN 57884 34b. SIT822 Gas Control Valve EP 57883 35. Sensing Electrode (w/ Cable) EN/EP 57885 36. Transformer 24V EN/EP 7522409 37. Ignition Module Honeywell EP 20000005 * Wire Harness Honeywell EN/EP 10001979
10006326

PRODUCT COVERED BY THIS WARRANTY All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic brand gas fireplaces equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner.
CFM Corporation (hereinafter referred to collectively as the Company) warrants that your new Vermont Castings or Majestic Gas Fireplace/ Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to the following conditions and limitations.
The heat exchanger, where applicable, and combustion chamber of every Vermont Castings or Majestic gas product is warranted for life against through wall perforation. All appliances equipped with an Insta-Flame Ceramic Burner have limited lifetime coverage on the ceramic burner plaque. Warrantees are made to the original owner subject to proof of purchase and the conditions and limitations listed on this Warranty Document
CAST IRON: All external and internal cast iron parts are warranted for a period of three years. Note: On porcelain enamel finished external parts and accessories The Company offers no Warranty on chipping of enamel surfaces. Inspect all product prior to accepting it for any damage to the enamel. The salt air environment of coastal areas or a high humidity environment can be corrosive to the porcelain enamel finish. These conditions can cause rusting of the cast iron beneath the porcelain enamel finish, which will cause the finish to flake off. Dye lot variations with replacement parts and/or accessories can occur and are not covered by warranty.
GLASS DOORS: Glass doors are covered for a period of one year. Glass doors are not warranted for breakage due to misuse or accident. Glass doors are not covered for discoloration or burned in stains due to environmental issues, or improper cleaning and maintenance.
BRASS PLATED PARTS AND ACCESSORIES: Brass parts should be cleaned with Lemon oil only. Brass cleaners cannot be used. Mortar mix and masonry cleaners may corrode the brass finish. The Company will not be responsible for, nor will it warrant any brass parts which are damaged by external chemicals or down draft conditions.
ELECTRONIC AND MECHANICAL COMPONENTS: Electronic and mechanical components of the burner assembly are covered for one year. All steel tube burners are warranted for one year.
as near-by trees, buildings, roof tops, hills, or mountains. b) Inadequate ventilation or negative air pressure caused by
ACCESSORIES: Unless otherwise noted all components and CFM Corporation company supplied accessories are covered for a period of one year.
mechanical systems such as furnaces, fans, clothes dryers, etc. • This warranty is void if: a) The fireplace has been operated in atmospheres contaminated
by chlorine, fluorine, or other damaging chemicals. b) The fireplace has been subjected to prolonged periods of dampness
or condensation c) Any damages to the fireplace, combustion chamber, heat exchanger
or other components due to water, or weather damage, which is the result of but not limited to, improper chimney/venting installation. d) Any alteration, willful abuse, accident, or misuse of the product
has occurred.
10006326


Model EnerGuide Ratings Steady State (%) D.O.E. Fireplace Efficiency (%) Fan-OFF Fan-ON (AFUE%) 360DVS2RN 62.4 83 84 65 360DVS2RP 62.4 83 84 65 360DVS2EN 62.4 83 84 65 360DVS2EP 62.4 83 84 65 360DVS3RN 62.4 83 84 65 360DVS3RP 62.4 83 84 65 360DVS3EN 62.4 83 84 65 360DVS3EP 62.4 83 84 65 360DVSLRN 62.4 83 84 65 306DVSLRP 62.4 83 84 65 360DVSLEN 62.4 83 84 65 360DVSLEP 62.4 83 84 65 360DVSRRN 62.4 83 84 65 360DVSRRP 62.4 83 84 65 360DVSREN 62.4 83 84 65 360DVSREP 62.4 83 84 65