SAFETY INFORMATION
PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE.
Pinnacle & Stardance Direct Vent, Rear Vent Gas Heater Models SDVR, PDV20: 3920, 3926, 3930, 3936, 3960, 3966, 3970, 3976, 4065, 4070, 4075, 4080
—Do not store or use gasoline or
other flammable vapors and liquids in the vicinity of this or any other appliance.
GAS:
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
and Operating Manual
This appliance may be installed in an after market permanently located manufactured (mobile) home where not prohibited by local codes.
E
S
G
N
This appliance is only for use with the type of gas indicated on the rating plate.
D
CERTIFIED
This appliance is not convertible for use with other gases unless a certified kit is used.
T
F
E
CFM Specialty Home Products
20007066 12/04 Rev. 3



The Pinnacle (PDV20) and Stardance (SDVR) Direct Vent Room Heater, Model Nos. 3920, 3926, 3930, 3936, 3960, 3966, 3970, 3976, 4065, 4070, 4075, 4080, are vented gas appliance listed to ANSI Standard Z21.88b- 2002 and CSA-2.33b-2002 for Vented Room Heaters, and CSA 2.17-M91, Gas-Fired Appliances For Use at High Al- titudes.
The PDV20 and SDVR Direct Vent Room Heater, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the Na- tional Electrical Code ANSI/NFPA 70, (latest edition), or of the current Canadian Electrical Code C22.1.
The installation of the PDV20 and SDVR Direct Vent Room Heaters must conform with local codes, or in the absence of local codes, with National Fuel Gas Code, ANSI Z223.1/NFPA 54 — latest edition and CSA B-149.1 (EX- CEPTION: Do not derate this appliance for altitude. Main- tain the manifold pressure at 3.5” w.c. for Natural Gas and 10” w.c. for LP gas at maximum input.) Refer to Page 37 (RF only).
Due to high temperatures this appliance should be located out of traffic and away from furniture and draperies.
This appliance is only for use with the type of gas indi- cated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used.
Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance.
Installation and replacement of gas piping, gas utilization equipment or accessories, and repair and servicing of equipment shall be performed only by a qualified agency. The term “qualified agency” means any individual, firm, corporation, or company that either in person or through a representative is engaged in and is responsible for (a) installation or replacement of gas piping, or (b), the connection, installation, repair, or servicing of equipment, who is experienced in such work, familiar with all precautions required, and has complied with all the requirements of the authority having jurisdiction.
Clothing or other flammable materials should not be placed on or near the appliance.
Any safety screen, glass or guard removed for servicing an appliance must be replaced prior to operating the appliance.
The appliance area must be kept clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
The flow of combustion and ventilation air must not be obstructed. The installation must include adequate accessibility and clearance for servicing and proper operation.
The PDV20 and SDVR Direct Vent Room Heaters should be inspected before use and at least annually by a qualified service agency. It is imperative that control compartments, burners, and circulating air passageways of the appliance be kept clean.
The PDV20 and SDVR Direct Vent Room Heaters and the individual shut-off valve must be disconnected from the gas supply piping during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).
Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
The PDV20 and SDVR Direct Vent Room Heaters must be isolated from the gas supply piping system by closing the individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig.
Do not burn wood, trash or any other material for which this appliance was not designed. This appliance is designed to burn either natural gas or propane only.
An accessible tap is located above the pilot/on-off knob for checking the inlet pressure.
This gas appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance.
'Direct Vent' describes a sealed combustion system in which incoming outside air for combustion and outgoing exhaust enter and exit through two separate concentric passages within the same sealed vent system. The sys- tem does not use room air to support combustion. The Direct Vent system permits the gas appliance to be vented directly to the outside atmosphere through the side of the house or vertically through the roof.
Verify proper operation after servicing. Proposition 65 Warning: Fuels used in gas, woodburning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm.
This appliance is approved for bedroom installations in the U.S. and Canada.
This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes.
California Health & Safety Code Sec. 25249.6 * Aftermarket: Completion of sale, nor for purpose of resale, from the manufacturer.
20007066


Fig. 1 PDV20 dimensions.

Fig. 2 SDVR dimensions.
20007066

WARNING:
Minimum Clearances to Combustible Materials
Measure side clearances as shown in Figures 3, 4 and 5 from the outer edge of the cast iron stove top. Measure rear clearances from the outermost surface of the steel rear skirt.
The PDV20 and SDVR heaters are approved for installation into an alcove constructed of combustible materials to the dimensions and clearances shown on the next page.
The same clearances apply in a standard parallel installation.
CL 18³⁄₄" (476mm) 2¹⁄₂" (64mm)
CL 18³⁄₄" (476mm)
2¹⁄₂" (63mm)
6" 6"
PDV20 SDVR ST128c ST128a
Fig. 3 Parallel installation minimum clearances and flue centerline.

Fig. 4 Corner installation minimum clearances.


Fig. 5 Alcove installation.

The PDV20 and SDVR Heaters must be installed on rigid flooring. When the heater is installed directly on any combustible surface other than wood flooring, a metal or wood panel extending the full width and depth of the unit must be used as the hearth. There are no other hearth requirements.

Weight: Fully assembled 350 lbs.

Fig. 6 Mantel / top trim clearances.
20007066

Horizontal Termination
Vented Gas Fireplace Heaters
The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest edition. (EXCEPTION: Do not derate this appliance for altitude. Maintain the manifold pressure at 3.5” w.c. for Natural Gas and 10” w.c. for Propane.)
Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4,500 feet (1,370m) above sea level.
For elevations above 4,500 feet (1,370m) in USA, installations must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction.
Measured after the first elbow. (Transition elbow)
In Canada, please consult provincial and/or local authorities having jurisdiction for installations at elevations above 4,500 feet (1,370m).
Vertical Run (in feet)
May use up to three 90° Elbows (Excluding elbow
of unit.)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Horizontal Run (in feet)
Fig. 7 Horizontal vent termination window.
* Not the transition elbow.

Vent Termination Clearances
When planning the installation, consider the location of the vent terminal and clearances. Some of the most common clearances to keep in mind are shown in Figure 9.
The vent should be placed so that people cannot be burned by accidentally touching the vent surfaces when the stove is operating.
The vent termination should be located where it cannot be damaged by such things as automobile doors, lawn mowers or snowblowers and it should be located away from areas where it could become blocked by snow, etc.
All Vertical Terminations in this area Re- quire use of the 2¹⁄₄” Restrictor Plate*
(Measured after the first elbow. (Transition elbow)
Other factors that influence where the installation will be sited include the location of outside walls, where additional heat may be desired in the home, where the family members gather most regularly, and perhaps most importantly, the distance limitations of the venting system.
Vertical Run (in feet)
Vertical terminations must be within this area
20 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
Horizontal Run (in feet)
Fig. 8 Vertical vent termination window.

There must not be any obstruction such as bushes, garden sheds, fences, decks or utility buildings within 24" from the front of the termination hood. Do not locate termination hood where excessive snow or ice build up may occur. Be sure to check vent termi- nation area after snow falls, and clear to prevent accidental blockage of venting system. When using snow blowers, make sure snow is not directed towards vent termination area.
Location of Vent Termination
It is imperative the vent termination be located observ- ing the minimum clearances as shown in Figure 9.
20007066

20007066

Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors.
Outside Corner Inside Corner
B = Combustible 6"(152mm) Noncombustible 2"(50mm)
A = Combustible 6"(152mm) Noncombustible 2"(50mm)
A
B
Balcony - with no side wall
Balcony - with perpendicular side wall
C = Maximum depth of 48" (1219mm) for recessed location. D = Minimum width for back wall of a recessed location. Combustible 38"(965mm) Noncombustible 24"(610mm)
H
J
G = Combustible & Noncombustible 12"(305mm)
E = Clearance from corner in recessed location. Combustible 6"(152mm) Noncombustible 2"(50mm)
Fig. 10 Termination clearances.

Vertical Termination Kit, 7/12-12/12 Pitch 7TDVSKVB (1) 7/12 - 12/12 Flashing and all of the other Vertical Termination parts.
The following kits are available to meet the needs of most installations. All pipe has a 7" outer diameter and includes a 4" diameter inner section. A (CG) designation indicates the part is finished in Charcoal Gray paint. Consult your dealer about other vent parts that may be appropriate to complete the installation. CFM Corporation Vent Components Rear Vent Kit 7TFSRSK (1) 20” Starter pipe (CG) for through wall installation (1) Side Wall Termination (1) Finishing Collar (CG) (1) Firestop (1)Zero Clearance Sleeve (1) Wall plate (CG) (1) Hardware Package
Vertical Termination, Flat Roof 7DVSKVF (1) Flat Flashing and all of the other Vertical Termination parts.
Twist Lock 12” Straight Pipe (CG) 7TFSDVP12 (1) 12” Non-adjustable Pipe
Twist Lock 12”-18” Straight Pipe (CG) (1) 12” - 18” Adjustable Pipe 7TFSDVP1218
Twist Lock 24" Straight Pipe (CG) 7TFSDVP24 (1) 24" Non-adjustable Pipe
Twist Lock 48" Straight Pipe (CG) 7TFSDVP48 (1) 48" Nonadjustable Pipe
Twist Lock 45-Degree Elbow (CG) 7TFSDVT45 for vertical offsets (1) 45-degree Elbow
Min. Through the Wall Vent Kit 7TFSSK (1) 90-Degree Elbow (CG) (1) 24" Straight pipe (CG) (1) 24” - 42” Adjustable Straight Pipe (1) Side Wall Termination (1) Firestop (1) Zero-clearance sleeve (1) Hardware package (1) Finishing plate (CG) (1) Finishing collar (CG) (4) Charcoal Gray flue pipe rings
Combination Offset/Roof Support 7DVCS Attic Insulation Shield 7DVAIS 7" Charcoal Gray Pipe Rings, (4) 7FSDRG 7" Polished Brass Pipe Rings (4) 7FSDRP Use the following approved CFM/Majestic vent compo- nents for fireplace installations vented through a masonry chimney: 7TFSCSK Transition Connector HEDV25 25-foot flex connector (two 25 foot sections) HEDV35 35-foot flex connector (two 35 foot sections) HEDV32T812 Vent termination for 8 x 12” flue HEDV32T1212 Vent termination for 12 x 12” flue HEDVT Round termination
Starter Kit for Below-Grade Installation 7TFSDVSKS (1) Snorkel Termination (7TDVSNORK)
Vertical Termination Kit, 1/12-6/12 Pitch 7TDVSKVA (1) Combination Horizontal Offset / Roof Support (1) Vertical Termination (1) Storm Collar (1) 1/12-6/12 Flashing (1) Finishing Plate (CG) (1) Finishing Collar (CG) (1) Polished Brass Flue Pipe Ring (1) Hardware Package
20007066

The stove is shipped fully assembled on its back. Unpack the stove and carefully set it upright.
1/4-20 x 3/8” Hex Head Bolt
Porcelain enamelled surfaces are fragile. Handle porcelain enamelled castings tenderly. Familiarize yourself with the assembly steps before you begin and proceed with deliberation and care. If possible, have assistance available.
1/2” Sheet Metal Screws FK101a
Place enamelled castings on a soft, cushioned surface until you are ready to assemble.
Fig. 11 Snapstat assembly and installation.
Avoid contact between the castings and other hard surfaces or objects.
If you are not installing a fan, proceed to the appropriate vent assembly section.
Fig. 12 The upper flange of the fan skirt should be located behind the lower edge of the shroud.
For RF Models only: Follow Step 3, then run the spliced female leads to the front of the stove and attach to PC board of RF valve. Then follow Step 5. 1. Attach the Snapstat to the Bracket using two #10 x 1/2" phillips sheet metal screws as shown in Figure 12. 2. Locate and remove the 1/4-20 x 3/8" hex head bolt installed in the hole in the right rear ledge of the firebox. (Fig. 11) Use that bolt to secure the Snapstat Bracket to the firebox. The mounting hole is slotted to allow you to adjust the bracket so that its head makes contact with the firebox surface. (Fig. 11) 3. Attach the Fan to the firebox by engaging the upper flange of the fan skirt under the lower edge of the Shroud and secure the skirt with the four screws provided with the kit. (Figs. 12, 13)
Fig. 13 Correct position of fan skirt installation.



Fig. 14 Attach rheostat to bracket.

Fig. 16 Apply sealant to the starter pipe, and fasten to stove with Phillips screws.

Fig. 15 Blower wiring diagram.
Direct Vent
General Information
The PDV20 and SDVR are approved for installation only with the vent components listed on Page 13. Follow the vent component instructions exactly. These instructions apply to both the PDV20 and the SDVR shell.
For U.S. installations: The venting system must conform with local codes and/or the current National Fuel Gas Code, ANSI Z223.1/NFPA 54
9³⁄₈” W x 10³⁄₈” H Wall Opening
For Canadian installations: The venting system must conform to the current CSA B149.1 installation code.
Use Rear Vent Kit 7TFSRSK for an installation where the heater is parallel to the wall and the vent system extends straight back through that wall.
Fig. 18 SDVR with Rear Vent Kit 7TFSRSK installation.
20007066



9³⁄₈” W x 10³⁄₈” H Wall Opening
Fig. 19 PDV20 with Rear Vent Kit 7TFSRSK installation.
3. Measure the wall thickness and cut the wall sleeve sections to proper length (MAXIMUM 12”). Assemble the sleeve with the #8 sheet metal screws supplied. Attach the firestop plate to the sleeve end with the holes. (Fig. 25) NOTE: The wall sleeve is required in combustible walls only. 4. Install the Wall Firestop/Sleeve assembly into the wall cutout and fasten the firestop to the wall cutout framing members. (Figs. 18, 19) 5. Measure, and cut if necessary, the appropriate length of pipe section needed to make the connec- tion through the wall. 6. Slip the wall plate and trim collar over the interior end of the horizontal pipe and install into the wall sleeve. Seal the joint inside the wall plate if needed to keep cold air from being drawn into the home. 7. Connect the pipe to the inner collar. Fasten the wall plate to the pipe with three sheet metal screws. Slide the trim collar up against the wall plate to cover the screws. (Figs. 18, 19)
Refer to Figures 20 & 21 for minimum centerline of wall opening. 1. Attach Inner Starter Pipe, (found in with the logset), to the stove. • Run a bead of sealant beneath the pipe bead and attach to the stove using three 1/4-20 x 3/8” phillips screws provided in the parts bag. (Fig. 22)
20007066



Fig. 24 Locate vent opening.
Fig. 22 Install inner starter pipe and inner elbow.


Fig. 25 Assemble the wall sleeve and firestop.
4. If necessary, measure to determine the vertical length (X) of pipe required from the first (transition) elbow to the wall cutout centerline, including a 2” overlap at the joint. (Fig. 26) Use a hacksaw or tin snips to trim the pipe as needed. 5. Install first the inner then the outer straight pipe section(s), trimmed end down, to the point of the elbow. Drill 3 holes through each joint and fasten with sheet metal screws. 6. Install the elbow using 3 sheet metal screws at each joint. 7. Measure, and cut if necessary, the appropriate length of pipe section needed to make the connec- tion through the wall. Include a 2” overlap; i.e. from
Fig. 23 Fasten outer pipe with #12 x 1/2” sheet metal screws.
20007066



Fig. 28 Install the horizontal pipe and wall plate parts.

Fig. 26 Determine the vertical pipe length.
the elbow to the outside wall face, about 2” or the distance required if installing a second 90° elbow. (Fig. 27) 8. Slip the wall plate and trim collar over the interior end of the horizontal pipe and install into the wall sleeve. Seal the joint inside the wall plate if needed to keep cold air from being drawn into the home.

Fig. 29 Install the vent terminal.
Install Snorkel #7TDVSNORK when it is not possible to meet the required vent termination clearances of 12” (305mm) above grade level. The snorkel kit will allow installation depth of down to 7” (178mm) below grade level. The seven inches is measured from the center of the horizontal vent pipe as it penetrates the wall. If the venting system is installed below grade, a window well must be installed with adequate and proper drainage. (Fig. 30)
ST215 Fig. 27 Measure the horizontal length.
9. Connect the horizontal pipe to the elbow. Fasten the wall plate to the pipe with three sheet metal screws. Slide the trim collar up against the wall plate to cover the screws. (Fig. 28) 10.Install the vent terminal. (Fig. 29) Guide the inner and outer vent termination collars into the adjacent pipes. Double check that the vent pipes overlap the collars by 2”. Fasten the termination to the wall with the screws provided, and caulk the joint with weath- erproof sealant. 11.Install Charcoal Gray Pipe Rings (#7FSDRG) or Polished Brass Pipe Rings (#7FSDRP) at pipe joints, if desired.
1. Establish the vent hole through the wall. 2. Remove soil to a depth of approximately 16” (400mm) below the base of the snorkel. Install a window well (not supplied). Refill the hole with 12” (305mm) of coarse gravel and maintain a clearance of at least 4” (102mm) below the snorkel. (Fig. 30) 3. Install the vent system as described on Pages 14- 17. 4. Be sure to make a watertight joint around the vent pipe joint at the inside and outside wall joints. 5. Apply high temperature sealant around the inner and outer snorkel collars. Join the pipes and fasten the snorkel termination to the wall with the screws provided.
20007066

Vent Assembly


Fig. 32 Install restrictor plate and starter pipe/inner elbow assembly.
Make certain the vent system conforms to all other requirements for vertical termination as specified on Page 9.
This installation will require you to first determine the roof pitch and use the appropriate vent components. Refer to Page 10, Figure 9.
1. Locate the final position of the stove, observing all clearances for both the vent and the stove. 2. Plumb to the center of the inner (4”) flue collar from the ceiling above, and mark that location. 3. Cut the opening: (Page 17, Fig. 24) 9³⁄₈” x 9³⁄₈” (240 x 240mm) 4. Plumb any additional opening through the roof or other construction that may be needed. In all cases, the opening must provide a minimum of 1” (25mm) clearance to the vent pipe. 5. Place the stove in its final position. 6. Install firestop(s) #7DVFS and Attic Insulation Shield #7DVAIS as needed. (Fig. 33) If there is a room above ceiling level, a firestop must be installed on both the bottom and top sides of the ceiling joists. If an attic is above ceiling level, an attic insulation shield must be installed. 7. Install the appropriate roof support and flashing, making certain that the upper flange of the flashing base is below the shingles. (Fig. 34)
Fig. 31 Use extension brackets to mount snorkel against recessed wall.
20007066

The heater must be vented to the outdoors through an existing masonry or prefabricated fireplace chimney system through the roof.
The heater is approved to be vented to the outdoors through any solid-fuel fireplace chimney that has been constructed or installed in accordance with the na- tional, Provincial/State and local building codes and is constructed of noncombustible materials. For Venting Requirements, refer to Page 10. Refer to Venting Components on Page 12.

NOTE: The collar extending down from the Termina- tion base is the air intake collar. Use the flex vent liner, marked with a blue line, to connect between this collar and the lower flue collar on the Transition Connector. Also make sure the other flex vent liner is attached to the upper Transition Connector collar and the Rain Cap. (Fig. 35)
Fig. 33 Install firestops and attic insulation shield.

Use three #5 sheet metal screws at each joint
1. Clean the top of the chimney as needed, to ensure a good seal between it and the vent termination. 2. Slide the insulation sleeves provided in the termina- tion kit over the two 3" flex liners (to be attached to the 3" flue collar and cap of the termination assem- bly). 3. Feed 3" flex vent from the bottom of the termination assembly up through the 4" sleeve. Apply high- temperature sealant to the rain cap collar, and slide the flex vent over the end of the rain cap collar, fastening with the clamp provided. 4. Slide the flex liner back through the 4" sleeve until the rain cap/collar engages over the sleeve. Attach the cap to the sleeve with three sheet metal screws provided in the kit. 5. Apply high-temperature sealant over the air intake collar, and attach the intake flex vent (blue) with a clamp.
Fig. 34 Roof support and flashing.
20007066

6. Apply high-temperature sealant to the top of the chimney. Feed the two liners down through the chimney flue and damper opening. Fasten the termination assembly to the chimney with the four set screws (C) provided. 7. Trim the flex liners as needed. Each should be only long enough to connect to the Transition Connector. There should be no sag in either flex liner when the stove is in place. 8. Attach the flex liners to the Transition Connector, using high-temperature sealant and clamps as shown in Figure 35. Prop the connector in rough position until the heater is in place in front of it.

A = Sealant Locations B = Sheet Metal Screws C = Termination Screws D = Clamps
Fig. 35 Fireplace vent system installation.
20007066


Fig. 36 PDV20 minimum lintel height for flush or forward placement.

“X” must be 6” (152mm) from any combustible material unless completely covered by field fabricated sheet metal. If 3” vent pipes are covered by sheet metal, the clearance to combustibles may be 2” (51mm).
* Transition pipe must be at least 6” (152mm) from any combustible material.
Fig. 37 PDV20 installations using existing wood stove chimney pipe.
20007066


Fig. 38 SDVR minimum lintel height for flush or forward placement.

“X” must be 6” (151mm) from any combustible material unless completely covered by field fabricated sheet metal. If 3” vent pipes are covered by sheet metal, the clearance to combustibles may be 2” (51mm).
* Transition pipe must be at least 6” (152mm) from any combustible material.
Fig. 39 SDVR installations using existing wood stove chimney pipe.
20007066

Check the rating plate attached by a steel cable to the firebox, to confirm that you have the appropriate firebox for the type of fuel to be used. The PDV20 and SDVR may be converted from one gas to another using the appropriate Fuel Conversion Kit listed on Page 41.
The appliance must only use the gas specified on the rating plate, unless converted using a Vermont Castings Fuel Conversion Kit. Refer to Page 41 for correct Fuel Conversion Kit for your stove model.
Coversion instructions are provided with each kit and beginning on Page 33 of this manual.
This appliance should only be connected by a qualified gas technician. Test to confirm manifold pressures as specified below.
The PDV20 and SDVR Heaters and the individual shutoff valves must be disconnected from the gas supply piping during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).
In order to connect Natural Gas, use a fitting with a 3/8” NPT nipple on the valve side and 1/2” natural gas supply line with an input of 21,000 BTU’s at a manifold pressure of 3.5” and minimum inlet supply for adjustment of 5.5” w.c.
The PDV20 and SDVR Heaters must be isolated from the gas supply piping system by closing the individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressure equal to or less than 1/2 psig.
In order to connect Propane, use a fitting with 3/8” NPT nipple on the valve side and 1/2” propane gas supply line with an input of 21,000 BTUs at a manifold pressure of 10.0” and minimum inlet supply for adjustment of 11.0” w.c.
There must be a gas shutoff between the stove and the supply.
In order to connect Natural Gas, use a fitting with 3/8” NPT nipple on the valve side and 1/2” natural gas supply line with an input of 21,000 BTUs at a manifold pressure of 3.5” and mini- mum inlet supply for adjustment of 5.5” w.c.
In order to connect Propane, use a fitting with 3/ 8” NPT nipple on the valve side and 1/2” propane gas supply line with an input of 21,000 BTUs at a manifold pressure of 10.0” and minimum inlet supply for adjustment of 11.0” w.c.
In the U.S.: Gas connection should be made in accordance with current National Fuel Gas Code, ANSI Z223.1/NFPA 54. Since some municipalities have additional local codes, be sure to consult your local authority.
The switch assembly parts are found in the parts bag. 1. Attach switch assembly to left rear side of stove shroud using two screws and existing holes in shroud. (Fig. 40) 2. Run wires down back of stove, under bottom of rear shroud to valve. 3. Attach wires to valve terminals. (Fig. 41)
In Canada: consult the local authority and CSA-B149.1 installation code.
Connect the gas supply and test for leaks. Use a mild soap and water solution applied with a brush no larger than 1” (25mm). Never apply soap and water solution with a spray bottle. Do not use an open flame for leak testing.
20007066


Use only a thermostat rated for 500 - 750 millivolts. Check the table below for the appropriate gauge thermostat wire to use for the length of lead required in your installation.
Thermostat Wire / Gauge Maximum Run 18 40 feet 20 25 feet 22 16 feet
ST228 Fig. 41 Attach switch wires to valve.
Grasp the Front Plate and lift it into position, engaging the two steel tabs at the upper corners behind the adjacent bosses in the Side Plates. (Fig. 42) Seat the Front against the Sides so that the tabs at the bottom lip engage with the notches in the edge of the stove base. When properly installed, the bottom of the Front Plate cannot be pulled away from the sides without also lifting it up.
If you are installing optional Warming Shelves, do so now, according to the instructions supplied with that kit.

Fig. 42 Install Stove Front.
20007066


Remove the logs from their packaging, and inspect each piece for damage. DO NOT INSTALL DAMAGED LOGS.
1. Install the rear log by centering it side to side on the sheet metal shelf at the back of the firebox. (Fig. 43) The log will touch both sides and back wall of the firebox. 2. Install the right log by placing right side of log on burner so it is just touching firebox side. Lay log flat on burner almost touching the decorative grate. Then tilt log back so that it leans against rear log. (Fig. 43) Only the topmost part of the left side of log will touch the rear log. The right log sits freely on the burner and does not use locator pins to stay in place. 3. Place left log on burner, making sure to engage locator pins in holes in bottom of the log. (Fig. 43) This log does not touch any other log. 4. Sprinkle lava rock on burner in front of, and between, left and right logs. (Fig. 44)
Fig. 44 Place lava rock on burner.
20007066

The Stardance is operated with the operable door front plate in place with the doors open or closed. To open the front doors, insert the handle into the door latch stub and turn it to the left and up. (Fig. 45) When not in use, the handle may be stored in the handle holder on the right side of the rear shroud. (Fig. 46)
Piezo Ignitor Button Pressure Tap
PILOT
OFF
H
O
ON
PILOT
ADJ
Regulator Control Knob Gas Control Knob Pilot Adjustment Screw HV104
Fig. 47 RN & RP valve control.
Fig. 45 To open the front doors, turn handle clockwise.
Fig. 48 Pilot Assembly location.
Fig. 46 When not in use, store handle in the handle holder.
Your First Fire
For stoves equipped with HI/LO valves, flame adjustment is accomplished by rotating the HI/LO adjustment knob located near the center of the gas control valve. (Fig. 49)
Read these instructions carefully and familiarize yourself with the burner controls shown in Figure 47. Locate the pilot assembly, Figure 48. Follow the lighting instructions on Page 28 exactly.
During the first fire, it is not unusual to smell some odor associated with new logs, paint and metal being heated. Odors should dissipate within a few hours. You can open a window to provide fresh air to alleviate the condition.
HI
to decrease flame height
to increase flame height
Fig. 49 Flame adjustment knob for Honeywell valve.
Each time you light your heater check that the pilot flame and burner flame pattern are as shown in Figures 50 through 52. If flame patterns are incorrect, turn the heater off. Contact your dealer or a qualified gas technician for assistance. Do not operate the heater until the pilot flame is correct.
It is important to periodically perform a visual check of the pilot and the burner flames. Compare them to Figures 50 through 52.
If any of the flames appear abnormal call a service person.
Follow regular maintenance procedures as described on Page 36.


Fig. 51 Correct pilot flame pattern. SIT pilot.
20007066

may result causing property damage, personal injury or loss of life.
A. This heater has a pilot which must be lit
manually. When lighting the pilot follow these instructions exactly. B. BEFORE LIGHTING smell all around the heater
control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Applying force or any attempted repair may result in a fire or explosion.
D. Do not use this fireplace if any part has been under
water. Immediately call a qualified service techni- cian to inspect the heater and to replace any part of the control system and any gas control which has been under water.
P
O
T
PILOT
F
ON
ON
F P
O
F
O
F
F
F
O
Euro SIT SIT NOVA Honeywell

Troubleshooting / Honeywell #8420 Gas Control System NOTE: Before troubleshooting the gas control system, be sure the external gas shutoff is in the “ON” position. WARNING: REMOVE THE GLASS PANEL BEFORE PERFORMING ANY GAS CONTROL SERVICE WORK.
A. Defective or misaligned
Using a match, light pilot. If pilot lights, turn off pilot and push the ignitor button again. If pilot will not light, check gap at electrode and pilot - it should be 1/8” to have a strong spark.
electrode at the pilot
B. Defective ignitor (push
Push piezo ignitor button. Check for spark at electrode and pilot. If there is no spark at the pilot, and electrode wire is properly connected, replace ignitor.
A. Defective pilot generator
Check pilot flame. It must impinge on the thermocouple or thermopile. NOTE: This pilot burner assembly uses both a thermocouple and a thermopile. The thermo- couple operates the pilot flame. Tighten the thermo- couple. The thermopile operates the main valve (ON and OFF). Clean and/or adjust pilot for maximum flame impingement on thermocouple and thermopile.
B. Defective automatic valve
Turn valve knob to ‘Pilot’. Maintain flow to pilot; millivolt meter should read greater than 10mV. If the reading is okay and the pilot does not stay on, replace the gas valve. NOTE: An interrupter block (not supplied) must be used to conduct this test.
A. Remote switch or wires
Check rocker switch and wires for proper connection. Use jumper wires across terminals at rocker switch. If burner lights, replace rocker switch. If okay, use jumper wires across rocker switch wires at the valve; if burner lights, wires are faulty or connections are bad.
B. Thermopile may not gener-
C. Plugged burner orifice
Check burner orifices for debris, and remove.
D. Defective automatic valve
Turn knob to ON, place rocker switch to ON, millivolt meter should read greater than 10 mV. If the reading is okay and the burner does not light, replace the valve.
A. Pilot flame may be too low
Clean and/or adjust pilot flame for maximum flame impingement on thermocouple and thermopile.
or high, (blowing or lifting), causing the pilot to drop out B. Possible blockage of the
Check the vent terminal for blockage.

The Comfort Control Valve allows remote control of temperature, fan and flame appearance.
If the manual switch is in the REMOTE position, the transmitter can shut off the main burner and fan. However, the control is still on and a command from the transmitter can turn on the main burner or fan.
1. If the manual switch is in remote position, switch it to LOCAL. (Fig. 53) 2. Turn the pilotstat knob counterclockwise from OFF to the PILOT position, push the knob down, and hold in position. The pilot valve opens and allows gas to flow to the pilot burner. 3. Push plunger on the piezo until the pilot burner is lit. When the pilot burner is lit, the LED on the control will come on after approximately 40 seconds and will provide 1 short blink continuously in the normal mode. When the light turns off which will be approxi- mately 10 seconds after it has been continuously red, the receiver/valve is fully powered.
To shut off the system, turn the pilotstat knob clockwise to the OFF position. This action closes the main gas and safety valves. The transmitter cannot turn on the main burner or fan.
Off Mode
In the OFF mode, the fireplace flame and fan are off, the display will show OFF and displays the room temperature. If the receiver is in REMOTE mode, the fireplace will shut off.


Room Temperature Set Temperature Flame Height Level Fan Speed Level Countdown Timer Low Battery
Increases Flame Height, Fan Speed Timer, or Set Point
Fig. 53 Comfort control valve.
Fig. 54 Transmitter diagram.
4. Release the knob. The shaft will move upward. The pilot burner should now stay burning. If the pilot burner goes out, repeat step 2. 5. Turn the knob counterclockwise to the ON position. If the manual switch is in the LOCAL position, the main burner will turn on immediately. 6. ON the initial use of a transmitter, a recognition operation is required between the receiver/valve and transmitter. Change the switch from LOCAL to REMOTE. Press the fan or flame button on the transmitter within 30 seconds. The LED will blink indicating the transmitter will now work with the receiver/valve. If the switch continues in the RE- MOTE position, the transmitter will now control the main valve, flame modulation level and fan control.
In the ON mode, the room temperature, flame and fan levels will be shown. MANUAL will appear next to both the flame and fan icons.
When the control is in the ON mode, the flame and fan levels, and delay timer are changed with the up and down buttons. To change the flame level, press the flame button followed by an arrow key. To change the fan level, press the fan key followed by an arrow key. Pushing the arrow key once will change the level by one unit.
The shut off delay timer has a maximum of 2 hours and a minimum of zero minutes. To change the timer level, press the time key followed by an arrow key. Pushing the key once will change the timer by 10 minutes.
20007066


In the AUTO mode, the room temperature, set tempera- ture, flame and fan levels will be shown. AUTO will appear next to both the flame and fan icons.
When the control is in the AUTO mode, the main burner will turn on/off or modulate based on the heat needed to maintain the set temperature. The flame level will change automatically to optimize the heat output needed to maintain the set temperature. To change the set temperature, press the up or down key. Pushing a key once will change the temperature by one degree.
In the AUTO mode, the fan speed will increase with increasing flame height or decrease with decreasing flame height. “AUTO” is displayed next to the flame and fan icons.
If a lower or higher fan speed is desired when operating in the AUTO mode, the fan speed can be overridden by pushing the fan button followed by the up or down key. Pushing a key once will change the fan level by one unit. In this mode “AUTO” is displayed next to the flame icon and “MANUAL” is displayed next to the fan icon.
Fig. 55 Comfort Valve wiring diagram.
If an Error Code 3 is observed while performing the
testing, complete the following: 1. Make sure the spade connectors are pushed all the way on. If rhe Error Code 3 is still showing, then go to the next step. 2. Switch the front two thermopile leads with the back two. Be sure the white lead is connected to the spade with the white dot next to it. If the Error Code 3 is still showing, replace the thermopiles. If an Error Code 8 is observed while performing the
Push the up and down arrow keys simultaneously for at least 3 seconds to toggle between Fahrenheit and Celsius units.
To disable the thermostat function in the AUTO mode, push the time and down keys simultaneously for at least 3 seconds.
LED Count Service Action
7 Confirm stepper motor connection exists
5 Confirm fan connection exists and works
4 Confirm gas type; jumper in place
2 Turn fan ON
8 Replace valve · 3 Replace thermopiles · 20007066

to local or remote
Did the LED stop
Review LED failure analysis.
knob.
and leave in remote. Press any
Turn pilotstat knob from PILOT to ON.
Remote path. Set switch to manual or
remote.
operation.
On Path
If manual switch is
If the manual switch
set to LOCAL, did
local to remote. Press any key on transmitter. Move
is set to REMOTE,
Move switch from manual to remote.
press the mode button to display “ON”.does transmit-
and fan turn on?
Press any key on
transmitter.
local.
ter control the main
to PILOT to turn
off main burner.
change levels of flame height, fan
to OFF to turn valve completely
off.
Set levels of flame
height and fan to “0” to shut off main
burner and fan.
to OFF to turn valve completely
off.

If the manual switch is
set to REMOTE, press the mode button to display AUTO on the
Move switch from LOCAL to REMOTE. Press any key within
OFF
H
O
ON
PILOT
ADJ
transmitter. Does the transmitter display the
30 seconds.
Main Gas Line Gas Supply Inlet
Fig. 56 Attach the gas line to the right side of the valve.
If the settings is above room temperture on the
Before proceeding, turn control knob on valve to OFF and turn gas supply OFF. Turn OFF any electricity that may be going to the appliance.
main valve and fan
1. Remove stove front. Lift stove front up and then swing bottom out and away to disengage from the stove body. (Page 36, Fig. 65) 2. Swing open the swiveling latches at the top left and right corners of the glass frame. (Page 37, Fig. 66) 3. Pull the top edge of the glass and frame assembly away from the firebox face. Place the assembly out of the way on a flat, padded surface such as a counter protected by a towel. 4. Remove the logset from the firebox. 5. Remove the rear log bracket by unfastening the screw. (Fig. 57) 6. Remove the right and left log bracket assembly by unfastening the two screws which hold the burner in place. (Fig. 57)
No If the settings is below room temperture on the
main valve and fan
Turn pilotstat knob to
OFF to turn valve
completely off.
WARNING! This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all appli- cable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with the kit.

Fig. 57 Remove rear log bracket and left and right log bracket assembly.


7. Hold the burner at the right hand side and lift to clear the right burner leg. Then pull to the right to clear the injectors on the left hand side. 8. Remove injector orifices from left burner leg using 1/2” wrench. (Fig. 64) 9. Install conversion orifices. (See Table 2) Models 3920, 3930, 4065, 4070 (R Models) Only 10.Remove cap from Hi-Lo knob. This can be accom- plished by lifting the plastic cap off the screw. (Fig. 58) 11.Remove the screw from center of Hi-Lo knob with small screwdriver turning counterclockwise. (Fig. 58) 12.Insert blue painted screw when converting to natural gas and red painted screw when converting to LP.


Fig. 58 Remove center screw from Hi-Lo knob.
Fig. 61 Remove pilot hood. (Your pilot may have a different appearance.)

20007066

All Models 21.Replace burner. Slide the burner in at an angle with left side lower than the right side. Slide the left side onto the injectors, making sure the burner leg remains at a 90° angle to the base. Lower the right hand side down in to place. Make sure the burner is as far left as possible and the injector shoulders are inside the burner. NOTE: It is very critical to keep the left burner leg,
firebox base after conversion. Models 3960, 3970, 4075, 4080 (RF Models) Only 16. Follow procedure for pilot type 2 to replace pilot orifice. 17. Remove and replace plug on lower right hand side of the valve; Red for LP and Blue for NG. (Page 30, Fig. 53) 18. Remove motor top cap. Depress and turn center plunger until arrow points to correct screw. Red for LP and Blue for NG. NOTE: Plunger will “snap” into NG position when arrow is close to blue screw. It will not “snap” at LP (Red) position. (Fig. 63) 19. Insure manifold pressure remains between 3.2” - 3.5” w.c. for NG and 9.5” - 10” w.c. for LP. To adjust the manifold pressure, for NG, using a torque #10 key turn the blue screw clockwise to increase the manifold pressure. Turn the screw counterclockwise to de- crease the pressure. Use the red screw to adjust LP. 20. Replace motor top cap.
which holds the injectors, at a 90° angle to the base. (Fig. 64) This keeps the orifices aligned with the tubes inside burner. Failure to do so could affect the flame appearance and performance of the unit. 22.Place conversion label on valve. 23.Reinstall the right and left log bracket assembly. 24.Reinstall the rear log bracket. 25.Replace logs. 25.Replace glass and stove front. Conversion is complete.

Conversion to Natural Gas Input (BTU/h) Kit # Front Part # Rear Part # Minimum Maxi,mum
000-5004 #56 / .0465” 30000336 #47 / .078” 20003054 14,000 21,000 000-5013 #56 / .0465” 30000336 #47 / .078” 20003054 14,000 21,000
Conversion to LP Input (BTU/h) Kit # Front Part # Rear Part # Minimum Maximum
000-5005 #68 / .031” 30000694 #56 / .0465” 30000336 14,000 21,000 000-5014 #68 / .031” 30000694 #56 / .0465” 30000336 14,000 21,000
20007066

Your PDV20 and SDVR Gas Heaters will provide years of service with minimal upkeep. The following proce- dures will help ensure that your stove continues to function properly.
TURN THE PILOT OFF BEFORE PAINTING. ALLOW THE HEATER TO COOL COMPLETELY BEFORE PAINTING.
Have the entire heater and venting system inspected annually by a qualified gas technician. Replace any worn or broken parts.
It will be necessary to clean the glass periodically. During start-up, condensation, which is normal, forms on the inside of the glass and causes lint, dust and other airborne particles to cling to the glass surface. Also initial paint curing may deposit a slight film on the glass. It is therefore recommended that the glass be cleaned two or three times with a non-ammonia house- hold cleaner and warm water (we recommend gas fireplace glass cleaner). After that the glass should be cleaned two or three times during each heating season depending on the circumstances present.
Cleanliness is critical to the proper function of the heater. The logset and burner must all be kept free of dust and unobstructed by debris. Inspect these areas before each use and clean as necessary.
1. Turn the burner OFF and let the heater cool com- pletely before cleaning. 2. Lift the Stove Front up and then swing the bottom out to disengage it from the heater shell. (Fig. 65) 3. Carefully remove the glass and frame assembly and place it out of the way on a flat, padded surface such as a counter protected by a towel. 4. Carefully inspect the Logs for damage. Contact your local dealer if any damage is evident. DO NOT OPERATE THE HEATER WITH DAMAGED LOGS. 5. Use a soft bristled brush to sweep dust or debris from the Logs, Pilot and Burner. Use care as the logs are fragile and susceptible to damage. 6. Replace the glass panel and frame assembly. 7. Replace the Stove Front.
Clean glass after first two weeks of operation.
Replace glass only with CFM Specialty Home Products approved parts. Refer to Page 39 for Replacement Parts. Refer to Figure 66 and previous instructions for removal of the damaged glass frame.
An occasional dusting with a dry rag will help keep the painted surfaces looking new. Use high-temperature stove paints, available through your local dealer, to touch-up areas as needed. Clean areas to be painted with a wire brush and be sure to cover the logs, burner and valve assembly, glass and frame assembly. Apply the paint sparingly; two light coats of paint will give better results than a single heavy coat.
Clean porcelain enamel surfaces with a soft, damp cloth. Do not use abrasive cleaning agents. If neces- sary, use only a cleaning agent formulated especially for use on porcelain enamel surfaces.
Fig. 65 Remove the Stove Front.
ST474d · 20007066


Have the vent system inspected annually by a qualified technician. Shut off the main gas supply before inspect- ing the system. Both the inner exhaust pipe and the outer combustion supply pipe must be checked to confirm that they are unblocked and in good condition.
To ensure that the stove is operating properly, check the flames periodically to confirm that they match Figures 50-52. The flames will be blue during the first 15-20 minutes of operation, and will gradually turn to yellow after that.
Fig. 66 Release the latches to release the glass frame.
The PDV20 and SDVR Gas Heaters use a ‘tadpole’ type gasket to seal between the glass panel and the frame. In time, this gasket can become brittle and compressed and should be replaced. New gasket is available from your dealer.
Do not use your stove if the flame pattern differs from that shown here. Contact your Vermont Castings dealer or a qualified technician for help.

Shut off the gas supply and allow the stove to cool. Wear safety goggles and a dust mask.
1. Remove the Front, Glass Frame and Glass Panel. (Figs. 65, 66) Remove the old gasket. Use a razor blade to separate the glass and gasket from the frame, and to clean the glass of any remaining cement or bits of gasket. Use a cold chisel if neces- sary. 2. Determine the correct length of gasket by laying it out around the edge of the glass. Allow an extra 1 - 2” (25-50mm). Mark the spot to be cut. Use a utility knife. 3. Starting on a long edge, remove about 6” of the protective paper strip and apply the flat adhesive face of the gasket around the outside-facing edge of the panel. Continue around the panel, applying about 6” at a time and being careful to not stretch the material. Do not overlap the gasket ends. (Fig. 67) 4. Apply a thin bead of high temperature silicone rubber sealant along the inside corner of the glass frame, all around the perimeter. Place the flat gasketed side of the glass panel back into the steel frame. Pinch the rounded inside-facing gasket material to bulk it up. 5. Replace the glass frame and front panel as previ- ously described.
Fig. 68 Correct flame pattern.


Fig. 69 Correct flame pattern, Models 2950, 2951.
Fig. 67 Wrap the gasket material around the outside edge of the glass.
20007066

If there is ever a need to remove the firebox assembly from the stove shell, support the firebox with solid stands about 6” (152mm) tall under the left and right outer edges of the firebox base. Do not set the firebox assembly directly on the floor; this can damage the control valve and/or the gas lines from the valve to the firebox.
POWER
CORD
WHT
BLK
BLK
Before removing the firebox from the shell, disconnect the on/off switch wires from the valve. If the assembly includes the optional fan, disconnect the fan rheostat. If the installation includes a wall thermostat, disconnect the thermostat leads from valve.
BLK
BLK
Disconnection and reconnection to the gas line should only be done by a qualified gas service technician.
Upon reinstallation, the vent system must be sealed to the firebox as shown in the installation section, page 14. Also be sure the logs are placed in the firebox correctly, as shown in Page 25, Figures 43-44.
ON / OFF Rheostat
OFF ON
BLK
WHT
BLK
GRN
RHEOSTAT / SNAPSTAT
TP/TH
BOX
TP
TH
MOTOR
BLK
BLK
BLK
TP/TH
SNAPSTAT
BLK
WHT
WHT
GRN
ON/OFF RHEOSTAT
TP
TH
Fig. 70 PDV20/SDVR on/off switch and optional thermostat circuit.
Fig. 71 PDV20/SDVR fan circuit.


CFM Specialty Homes Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
Pinnacle (PDV20) / Stardance (SDVR) Direct Vent/Rear Vent Gas Heater: Models 3920, 3926, 3930, 3936, 3960, 3966, 3970, 3976, 4065, 4070, 4075, 4080
20007066

Ref. Description PDV20 SDVR 1. Gas Log Assembly 20003467 20003467 1a. Log, Rear 20003463 20003463 1b. Log, Right 20003464 20003464 1c. Left Log 20003465 20003465 2. Grille, UV30 30000393 30000393 3. Mesh, Grille - UV30 30000508 30000508 4. Cement, Gasket 3oz. Tube 1206122 1206122 5. Manifold Assembly 20003739 20003739 6. Lava Rocks Burner 57897 57897 7. Gasket, Glass - Med. Knit-RDV40 1203702 1203702 8. Glass, DV25 1601691 1601691 9. Glass Frame Assembly, SDV30 30000127 30000127 10a. Gas Valve, NG - Honeywell VS8420E 2038 10001782 10001782 10b. Gas Valve, LP - Honeywell VS8420E 2020 10001759 10001759 11a. Valve Gas Honeywell Convertible RFN RV8310E 20003719 20003719 11b. Valve Gas Honeywell Convertible RFP RV8310E 20003720 20003720 12a. Pilot Assembly 3Way N/DV RN 0.199.706 10002264 10002264 Pilot Assembly 3Way N/DV RP 0.199.703 10002265 10002265 12b. Pilot, PSE - NA175 20001115 20001115 Pilot, PSE - LP175 20001116 20001116 12c. Pilot Assembly 3Way DV/RFN CS3003A2009 20002266 20002266 Pilot Assembly 3Way DV/RFP CS3003A2017 20002268 20002268 13. Thermocouple, 24” 53373 53373 7531137 7531137 14. Electrode Ignitor w/ Cable SIT24 10001297 10001297 15. Pilot Top Convertible 10002266 10002266 16. Thermopile, 18” RS 51827 51827 7533113 7533113 17. Nut Electrode, SIT #0.974.144 57886 57886 18. Tubing Pilot w/ Fittings 1/8 x 24” 10001296 10001296 19. Thermopile - PSE for RF Pilots 20002400 20002400 20a. Orifice Hood - Front - LP 30000694 30000694 20b. Orifice Hood - Front - NG 30000336 30000336 20c. Orifice Hood - Rear - LP 30000336 30000336 20d. Orifice Hood - Rear - NG 20003054 20003054 21. Burner Housing Assembly 20004066 20004066 22. Grate, Burner JDV 20002167 20002167 23. Wire w/Straight Terms End 50” 10002582 10002582 24. Trim ON/OFF Switch - JDV 53606 53606 25. Control FS/HM Refer to Enamel Parts Chart Page 41 26. Bracket, Right Log 20005259 20005259 27. Bracket, Left Log 20002165 20002165 28. Gasket Base Pan 20002282 20002282 29. Gasket Inner Base Pan 20002566 20002566
20007066

Ref. Description PDV20 SDVR 30. Top, Stardance UV/PDV Refer to Enamel Parts Chart Page 41 31. Front, HM-VC Refer to Enamel Parts Chart Page 41 32. Door, Left - Stardance Refer to Enamel Parts Chart Page 41 33. Door, Right - Stardance Refer to Enamel Parts Chart Page 41 34 Front, Stardance OP Door Refer to Enamel Parts Chart Page 41 35. Nut, Hex Jam 3/8 - 16 TOPLK-Z 1203290 1203290 36. Pawl Assy, Ashdoor - ENC 5004025 5004025 37. Front Handle Shaft - NI/VER 5004237 5004237 38. Handle Package, Ceramic w/Screw 0004342 0004342 39. Rear Shroud Assembly, PDV20 20003801 20003801 40. Gasket, HE Door 1203687 1203687 41. Left End, PDV20 Refer to Enamel Parts Chart Page 41 42. Right End, PDV20 Refer to Enamel Parts Chart Page 41 43. Left End, SDVR Refer to Enamel Parts Chart Page 41 44. Right End, SDVR Refer to Enamel Parts Chart Page 41 45. Transmitter Honeywell RF 20002047 20002047 46. FK28 Fan Subassembly for PDVRF 30000887 30000887
Fuel Conversion Kits Conversion Kit, NG to LP Kit #000-5005 PDV20RFN (Models 2997, 4075, 4076, 4077) and SDV30RFN (Models 3960 thru 3966) Conversion Kit, NG to LP Kit #000-5014 PDV20RN (Models 2995, 4065, 4066, 4067) and SDV30RN (Models 3920 thru 3926) Conversion Kit, LP to NG Kit #000-5004 PDV20RFP (Models 2998, 4080, 4081, 4082) and SDV30RFP Models 3970 thru 3976) Conversion Kit, LP to NG Kit #000-5013 PDV20RP (Models 2996, 4070, 4071, 4072) and SDV30RP Models 3930 thru 3936)
Shell Enamel Part Numbers - PDV20
Color Top Left End Right End Front Control Door Classic 30001278 30001282 30001281 1301129 1301087 Sand 30001299 30001303 30001302 1321129 1321087 Midnight 30001306 30001310 30001309 1341129 1341087
Shell Enamel Part Numbers - SDVR
Color Top Left End Right End Front (OP) Left Door Right Door Classic 30001278 30001280 30001279 30001496 30001139 30001138 Red 30001285 30001287 30001286 30001261 30001263 30001262 Sand 30001299 30001301 30001300 30001267 30001269 30001268 Midnight 30001306 30001308 30001307 30001270 30001272 30001271 Green 30001292 30001294 30001293 30001264 30001266 30001265 Suede Brown 30002554 30002547 30002548 30002550 30002552 30002551 Moonlight 30001319 30001321 30001320 30001314 30001316 30001315
20007066

Screen Kit
An optional screen, S30SK, for use with the operable doors is available for the Stardance only. The screen is used when the doors are left in the open position.
The FK28 fan helps distribute heated air from within the firebox out into the room. The fan is controlled by a snapstat that turns power on and off as the firebox temperature rises above and falls below a preset temperature. A rheostat provides for variable fan speeds.
Warming shelves add versatility to your stove; they can be used to keep foods warm at mealtime.
2702 Classic Black 2704 Red (Stardance only) 2706 Green (Stardance only) 2711 Moonlight Blue (Stardance only) 2764 Sand 2765 Midnight
115 Volt / 60Hz / .75 Amps
The fan itself does not require regular maintenance, however, periodic cleaning of the fan and the surrounding area is required.
The shelf installation is done in three stages. First you attach the shelf loosely to the stove, leaving the screws loose enough to allow final adjustments. Then, you position the shelf and adjust the brackets so the shelf fits correctly. Finally, you tighten the screws.
Refer to Page 13 for installation instructions.
The remote control allows you to turn the heater on or off from anywhere in the room. Refer to Page 40 for wiring diagrams.
Refer to the instructions included with each warming shelf for complete installation procedures.
MRC1 ON/OFF MRC2 ON/OFF and Temperature MRC3 ON/OFF and Temperature control with a digital display and a programmable 24 hour clock IMT Wall mounted thermostat control

PRODUCT COVERED BY THIS WARRANTY All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic or Northern Flame brand gas fireplaces equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner.
CFM Specialty Home Products (hereinafter referred to collectively as the Company) warrants that your new Vermont Castings or Majestic Gas Fireplace/Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to the following conditions and limitations.
The heat exchanger, where applicable, and combustion chamber of every Vermont Castings or Majestic gas product is warranted for life against through wall perforation. All appliances equipped with an Insta-Flame Ceramic Burner have limited lifetime coverage on the ceramic burner plaque. Warrantees are made to the original owner subject to proof of purchase and the conditions and limitations listed on this Warranty Document
CAST IRON: All external and internal cast iron parts are warranted for a period of three years.
Note: On porcelain enamel finished external parts and accessories The Company offers no Warranty on chipping of enamel surfaces. Inspect all product prior to accepting it for any damage to the enamel. The salt air environment of coastal areas or a high humidity environment can be corrosive to the porcelain enamel finish. These conditions can cause rusting of the cast iron beneath the porcelain enamel finish, which will cause the finish to flake off. Dye lot variations with replacement parts and/or accessories can occur and are not covered by warranty.
GLASS DOORS: Glass doors are covered for a period of one year. Glass doors are not warranted for breakage due to misuse or accident. Glass doors are not covered for discoloration or burned in stains due to environmental issues, or improper cleaning and maintenance.
BRASS PLATED PARTS AND ACCESSORIES: Brass parts should be cleaned with Lemon oil only. Brass cleaners cannot be used. Mortar mix and masonry cleaners may corrode the brass finish. The Company will not be responsible for, nor will it warrant any brass parts which are damaged by external chemicals or down draft conditions.
ELECTRONIC AND MECHANICAL COMPONENTS: Electronic and mechanical components of the burner assembly are covered for one year. All steel tube burners are warranted for one year.
as near-by trees, buildings, roof tops, hills, or mountains. b) Inadequate ventilation or negative air pressure caused by
mechanical systems such as furnaces, fans, clothes dryers, etc. • This warranty is void if: a) The fireplace has been operated in atmospheres contaminated
ACCESSORIES: Unless otherwise noted all components and CFM Specialty Home Products company supplied accessories are covered for a period of one year.
by chlorine, fluorine, or other damaging chemicals. b) The fireplace has been subjected to prolonged periods of
dampness or condensation c) Any damages to the fireplace, combustion chamber, heat exchanger or other components due to water, or weather damage, which is the result of but not limited to, improper chimney/venting installation. d) Any alteration, willful abuse, accident, or misuse of the product
has occurred.
20007066

Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| 1. Spark ignitor will not light | p.29 | ||
| 1. Spark ignitor will not light | p.29 | ||
| 2. Pilot will not stay lit after carefully following the lighting instructions | p.29 | ||
| 2. Pilot will not stay lit after carefully following the lighting instructions | p.29 | ||
| 3. Pilot lights, no gas to burner, valve knob ON, remote switch (rocker switch) ON | p.29 | ||
| 3. Pilot lights, no gas to burner, valve knob ON, remote switch (rocker switch) ON | p.29 | ||
| 4. Frequent pilot outage | p.29 | ||
| 4. Frequent pilot outage | p.29 |