Tripp Lite B096-048

224 pages·6.2 MB·Network Card·PDF·ENDEFRITNLJA
Tripp Lite B096-048
Table of Contents 80 sections Owner’s Manual · Console Server Management Switch · & Console Server with PowerAlert · INDEX · … ShowHide
Owner’s Manualp.1Console Server Management Switchp.1& Console Server with PowerAlertp.1INDEXp.21. INTRODUCTION 9p.22. INSTALLATION 14p.23. INITIAL SYSTEM CONFIGURATION 18p.24. SERIAL PORT AND NETWORK HOST 33p.25. FAILOVER AND OUT-OF-BAND ACCESS 52p.36. SECURE TUNNELING AND SDT CONNECTOR 60p.37. ALERTS AND LOGGING 93p.4POWER & ENVIRONMENTAL MANAGEMENT 103p.4AUTHENTICATION 117p.5NAGIOS INTEGRATION 125p.511. SYSTEM MANAGEMENT 140p.612. STATUS REPORTS 143p.613. MANAGEMENT 146p.614. BASIC CONFIGURATION - LINUX COMMANDS 151p.615. ADVANCED CONFIGURATION 168p.715.8 HTTPS 190p.716. THIN CLIENT (B092-016) 202p.71. INTRODUCTIONp.9This Manualp.9FCC Informationp.9RoHSp.9User Noticep.9Manual Organizationp.10Types of usersp.11Management Consolep.11Manual Conventionsp.12Publishing history Date Revision Update details January 2009 0.9 Initial draftp.132. INSTALLATIONp.14Networkp.14Consolep.14USB Portp.14Modem Powerp.14Portsp.14Portp.142.2 Power connectionp.152.3 Network connectionp.162.4 Serial Port connectionp.162.5 USB Port Connectionp.173. INITIAL SYSTEM CONFIGURATIONp.18Introductionp.183.1 Management Console Connectionp.183.1.1 Connected computer set upp.183.2 Administrator Passwordp.213.3 Network IP addressp.223.4 System Servicesp.243.5 Communications Softwarep.273.6 Management Network Configuration (B096-048/016 only)p.294. SERIAL PORT AND NETWORK HOSTp.334.1 Configuring Serial Portsp.334.2 Add/Edit Usersp.414.3 Authenticationp.444.4 Network Hostsp.444.5 Trusted Networksp.464.6 Serial Port Cascadingp.475. FAILOVER AND OUT-OF-BAND ACCESSp.525.1 OoB Dial-In Accessp.52Note For all PPP clients:p.565.2 OoB Broadband Access (B096-048/016 only)p.565.3 Broadband Ethernet Failover (B096-048/016 only)p.565.4 Dial-Out Failoverp.586. SECURE TUNNELING AND SDT CONNECTORp.606.1 Configuring for SDT Tunneling to Hostsp.616.3 SDT Connector to Management Consolep.756.4 SDT Connector - Telnet or SSH connect to serially attached devicesp.766.5 Using SDT Connector for out-of-band connection to the gatewayp.776.6 Importing (and exporting) preferencesp.796.7 SDT Connector Public Key Authenticationp.796.8 Setting up SDT for Remote Desktop Accessp.806.9 SDT SHH Tunnel for VNCp.857. ALERTS AND LOGGINGp.937.1 Configure SMTP/SMS/SNMP/Nagios alert servicep.937.2 Activate Alert Events and Notificationsp.967.3 Remote Log Storagep.1007.4 Serial Port Loggingp.1017.5 Network TCP or UDP Port Loggingp.102POWER & ENVIRONMENTAL MANAGEMENTp.103
Page 1 of the Tripp Lite B096-048 user manual — & Console Server with PowerAlert
Page 1 · click to enlarge
Page 1
Registrationregister online today for a chance to win a FREE Tripp Lite product— www.tripplite.com/warranty

Owner’s Manual

Console Server Management Switch

ModelsB096-016 / B096-048

& Console Server with PowerAlert

ModelB092-016

Tripp Lite World Headquarters 1111 W. 35th Street, Chicago, IL 60609 USA (773) 869-1234 (USA) • 773.869.1212 (International)

www.tripplite.com

Copyright © 2009 Tripp Lite. All rights reserved. All trademarks are the property of their respective owners.

Warranty

Page 2 of the Tripp Lite B096-048 user manual — Table of Contents
Page 2 · Contents
Contents

Contents

Owner’s Manualp.1Console Server Management Switchp.1& Console Server with PowerAlertp.1INDEXp.21. INTRODUCTION 9p.22. INSTALLATION 14p.23. INITIAL SYSTEM CONFIGURATION 18p.24. SERIAL PORT AND NETWORK HOST 33p.25. FAILOVER AND OUT-OF-BAND ACCESS 52p.36. SECURE TUNNELING AND SDT CONNECTOR 60p.37. ALERTS AND LOGGING 93p.4POWER & ENVIRONMENTAL MANAGEMENT 103p.4AUTHENTICATION 117p.5NAGIOS INTEGRATION 125p.511. SYSTEM MANAGEMENT 140p.612. STATUS REPORTS 143p.613. MANAGEMENT 146p.614. BASIC CONFIGURATION - LINUX COMMANDS 151p.615. ADVANCED CONFIGURATION 168p.715.8 HTTPS 190p.716. THIN CLIENT (B092-016) 202p.71. INTRODUCTIONp.9This Manualp.9FCC Informationp.9RoHSp.9User Noticep.9Manual Organizationp.10Types of usersp.11Management Consolep.11Manual Conventionsp.12Publishing history Date Revision Update details January 2009 0.9 Initial draftp.132. INSTALLATIONp.14Networkp.14Consolep.14USB Portp.14Modem Powerp.14Portsp.14Portp.142.2 Power connectionp.152.3 Network connectionp.162.4 Serial Port connectionp.162.5 USB Port Connectionp.173. INITIAL SYSTEM CONFIGURATIONp.18Introductionp.183.1 Management Console Connectionp.183.1.1 Connected computer set upp.183.2 Administrator Passwordp.213.3 Network IP addressp.223.4 System Servicesp.243.5 Communications Softwarep.273.6 Management Network Configuration (B096-048/016 only)p.294. SERIAL PORT AND NETWORK HOSTp.334.1 Configuring Serial Portsp.334.2 Add/Edit Usersp.414.3 Authenticationp.444.4 Network Hostsp.444.5 Trusted Networksp.464.6 Serial Port Cascadingp.475. FAILOVER AND OUT-OF-BAND ACCESSp.525.1 OoB Dial-In Accessp.52Note For all PPP clients:p.565.2 OoB Broadband Access (B096-048/016 only)p.565.3 Broadband Ethernet Failover (B096-048/016 only)p.565.4 Dial-Out Failoverp.586. SECURE TUNNELING AND SDT CONNECTORp.606.1 Configuring for SDT Tunneling to Hostsp.616.3 SDT Connector to Management Consolep.756.4 SDT Connector - Telnet or SSH connect to serially attached devicesp.766.5 Using SDT Connector for out-of-band connection to the gatewayp.776.6 Importing (and exporting) preferencesp.796.7 SDT Connector Public Key Authenticationp.796.8 Setting up SDT for Remote Desktop Accessp.806.9 SDT SHH Tunnel for VNCp.857. ALERTS AND LOGGINGp.937.1 Configure SMTP/SMS/SNMP/Nagios alert servicep.937.2 Activate Alert Events and Notificationsp.967.3 Remote Log Storagep.1007.4 Serial Port Loggingp.1017.5 Network TCP or UDP Port Loggingp.102POWER & ENVIRONMENTAL MANAGEMENTp.103
Page 3 of the Tripp Lite B096-048 user manual — 6. SECURE TUNNELING AND SDT CONNECTOR 60
Page 3 · click to enlarge
Page 3

4.1.3 SDT Mode 39

4.1.4 Device (RPC, UPS, EMD) Mode 39

4.1.5 Terminal Server Mode 39

4.1.6 Serial Bridging Mode 40

4.1.7 Syslog 41

4.2 Add/Edit Users 41

4.3 Authentication 44

4.4 Network Hosts 44

4.5 Trusted Networks 46

4.6 Serial Port Cascading 47

4.6.1 Automatically generate and upload SSH keys 47

4.6.2 Manually generate and upload SSH keys 48

4.6.3 Configure the Slaves and their serial ports 50

4.6.4 Managing the Slaves 51

5. FAILOVER AND OUT-OF-BAND ACCESS 52

5.1 OoB Dial-In Access 52

5.1.1 Configure dial-in PPP 52

5.1.2 Using SDT Connector client for dial-in 54

5.1.3 Set up Windows XP/ 2003/Vista client for dial-in 54

5.1.4 Set up earlier Windows clients for dial-in 55

5.1.5 Set up Linux clients for dial-in 56

5.2 OoB Broadband Access (B096-048/016 only) 56

5.3 Broadband Ethernet Failover (B096-048/016 only) 56

5.4 Dial-Out Failover 58

6. SECURE TUNNELING AND SDT CONNECTOR 60

6.1 Configuring for SDT Tunneling to Hosts 61

6.2 SDT Connector Configuration 61

6.2.1 SDT Connector client installation 62

6.2.2 Configuring a new gateway in the SDT Connector client 63

6.2.3 Auto-configure SDT Connector client with the user’s access privileges 64

6.2.4 Make an SDT connection through the gateway to a host 65

6.2.5 Manually adding hosts to the SDT Connector gateway 66

6.2.6 Manually adding new services to the new hosts 67

6.2.7 Adding a client program to be started for the new service 69

6.2.8 Dial- in configuration 70

Page 4 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT 103
Page 4 · click to enlarge
Page 4

6.2.9 Choosing an alternate SSH client (e.g. PuTTY) 70

6.3 SDT Connector to Management Console 75

6.4 SDT Connector - Telnet or SSH connect to serially attached devices 76

6.5 Using SDT Connector for out-of-band connection to the gateway 77

6.6 Importing (and exporting) preferences 79

6.7 SDT Connector Public Key Authentication 79

6.8 Setting up SDT for Remote Desktop access 80

6.8.1 Enable Remote Desktop on the target Windows computer to be accessed 80

6.8.2 Configure the Remote Desktop Connection client 81

6.9 SDT SHH Tunnel for VNC 85

6.9.1 Install and configure the VNC Server on the computer to be accessed 85

6.9.2 Install, configure and connect the VNC Viewer 86

6.10 Using SDT to IP connect to hosts that are serially attached to the gateway 88

6.10.1 Establish a PPP connection between the host COM port and Console Server 88

6.10.2 Set up SDT Serial Ports on Console Server 91

6.10.3 Set up SDT Connector to ssh port forward over the Console Server Serial Port 92

7. ALERTS AND LOGGING 93

7.1 Configure SMTP/SMS/SNMP/Nagios alert service 93

7.1.1 Email alerts 93

7.1.2 SMS alerts 94

7.1.3 SNMP alerts 95

7.1.4 Nagios alerts 96

7.2 Activate Alert Events and Notifications 96

7.2.1 Add a new alert 97

7.2.2 Select general alert type 98

7.2.3 Configuring environment and power alert type 99

7.3 Remote Log Storage 100

7.4 Serial Port Logging 101

7.5 Network TCP or UDP Port Logging 102

POWER & ENVIRONMENTAL MANAGEMENT 103

8.1 Remote Power Control (RPC) 103

8.1.1 RPC connection 103

8.1.2 RPC alerts 105

8.1.3 RPC status 105

Page 5 of the Tripp Lite B096-048 user manual — NAGIOS INTEGRATION 125
Page 5 · click to enlarge
Page 5

8.1.4 User power management 105

8.2 Uninterruptible Power Supply Control (UPS) 106

8.2.1 Managed UPS connections 106

8.2.2 Configure UPS powering the Console Server 109

8.2.3 Configuring powered computers to monitor a Managed UPS 110

8.2.4 UPS alerts 111

8.2.5 UPS status 111

8.2.6 Overview of Network UPS Tools (NUT) 111

8.3 Environmental Monitoring 113

8.3.1 Connecting the EMD 114

8.3.2 Environmental alerts 115

8.3.3 Environmental status 115

AUTHENTICATION 117

9.1 Authentication Configuration 117

9.1.1 Local authentication 118

9.1.2 TACACS authentication 118

9.1.3 RADIUS authentication 119

9.1.4 LDAP authentication 120

9.1.5 RADIUS/TACACS user configuration 121

9.2 PAM (Pluggable Authentication Modules) 122

9.3 Secure Management Console Access 123

NAGIOS INTEGRATION 125

10.1 Nagios Overview 125

10.2 Central management 126

10.2.1 Set up central Nagios server 126

10.2.2 Set up distributed Console Servers 127

10.3 Configuring Nagios distributed monitoring 129

10.3.1 Enable Nagios on the Console Server 129

10.3.2 Enable NRPE monitoring 131

10.3.3 Enable NSCA monitoring 132

10.3.4 Configure selected Serial Ports for Nagios monitoring 132

10.3.5 Configure selected Network Hosts for Nagios monitoring 133

10.3.6 Configure the upstream Nagios monitoring host 134

10.4 Advanced Distributed Monitoring Configuration 135

10.4.1 Sample Nagios configuration 135

Page 6 of the Tripp Lite B096-048 user manual — 14. BASIC CONFIGURATION - LINUX COMMANDS 151
Page 6 · click to enlarge
Page 6

10.4.2 Basic Nagios plug-ins 138

10.4.3 Additional plug-ins 138

11. SYSTEM MANAGEMENT 140

11.1 System Administration and Reset 140

11.2 Upgrade Firmware 141

11.3 Configure Date and Time 142

12. STATUS REPORTS 143

12.1 Port Access and Active Users 143

12.2 Statistics 143

12.3 Support Reports 144

12.4 Syslog 144

13. MANAGEMENT 146

13.1 Device Management 146

13.2 Port and Host Management 146

13.3 Power Management 147

13.4 Serial Port Terminal Connection 147

13.5 Remote Console Access (B092-016 only) 149

14. BASIC CONFIGURATION - LINUX COMMANDS 151

14.1 The Linux Command line 152

14.2 Administration Configuration 154

14.3 Date and Time Configuration 155

14.4 Network Configuration 156

14.5 Serial Port Configuration 159

Serial Port Settings 159

Supported Protocol Configuration 160

14.6 Event Logging Configuration 162

Remote Serial Port Log Storage 162

Show 7 more labels / short text on this page
System Settings 154 · Authentication Configuration 154 · IP Configuration 156 · Dial-in Configuration 157 · Services Configuration 158 · Users 160 · Trusted Networks 161
Page 7 of the Tripp Lite B096-048 user manual — 16. THIN CLIENT (B092-016) 202
Page 7 · click to enlarge
Page 7

14.7 SDT Host Configuration 163

SDT Host TCP Ports 163

14.8 Configuration backup and restore 165

14.9 General Linux command usage 166

15. ADVANCED CONFIGURATION 168

15.1 Advanced Portmanager 169

15.2 External Scripts and Alerts 171

15.3 Raw Access to Serial Ports 173

15.4 IP- Filtering 174

15.5 Modifying SNMP Configuration 176

Adding more than on SNMP server 177

15.6 Secure Shell (SSH) Public Key Authentication 178

Generating Public Keys (Linux) 179

Installing the SSH Public/Private Keys (Clustering) 180

Installing SSH Public Key Authentication (Linux) 180

Generating Public/Private keys for SSH (Windows) 182

SSH tunneled serial bridging 185

SDT Connector Public Key Authentication 188

15.7 Secure Sockets Layer (SSL) Support 189

15.8 HTTPS 190

15.9 Power Strip Control 192

Adding new RPC devices 194

15.10 IPMItool 196

15.11 Scripts for Managing Slaves 200

16. THIN CLIENT (B092-016) 202

16.1 Local Client Service Connections 202

16.1.1 Connect- serial terminal 204

16.1.2 Connect- browser 204

16.1.3 Connect- VNC 205

Show 5 more labels / short text on this page
Alert Configuration 163 · SSH Overview 178 · Fingerprinting 184 · PowerMan 192 · pmpower 194
Page 8 of the Tripp Lite B096-048 user manual — 15. ADVANCED CONFIGURATION 168
Page 8 · click to enlarge
Page 8

16.1.4 Connect- SSH 206

16.1.5 Connect- IPMI 207

16.1.6 Connect- Remote Desktop (RDP) 208

16.1.7 Connect- Citrix ICA 209

16.1.8 Connect- PowerAlert 209

16.2 Advanced Control Panel 210

16.2.1 SystemTerminal 210
16.2.2 SystemShutdown / Reboot 211
16.2.3 SystemLogout 211

16.2.4 Custom 211

16.2.5 Status 211

16.2.6 Logs 211

16.3 Remote control 212

Appendix A Hardware Specification 213

Appendix B Serial Port Connectivity 214

Appendix C End User License Agreement 216

Appendix D Service and Warranty 223

Page 9 of the Tripp Lite B096-048 user manual — User Notice
Page 9 · click to enlarge
Page 9

1. INTRODUCTION

This Manual

This User Manual is provided to help you get the most from your B096-016 / B096-048 Console Server Management Switch or B092-016 Console Server with PowerAlert product. These products are referred to generically in this manual as Console Servers.

Once configured, you will be able to use your Console Server to securely monitor, access and control the computers, networking devices, telecommunications equipment, power supplies and operating environment in your data center, branch office or communications room. This manual guides you in managing this infrastructure locally (at the rack side or across your operations or management LAN or through the local serial console port), and remotely (across the Internet, private network or via dial up).

FCC Information

This is an FCC Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.

This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.

RoHS

This product is RoHS compliant.

User Notice

All information, documentation and specifications contained in this manual are subject to change without prior notification by the manufacturer. The manufacturer makes no representations or warranties, either expressed or implied, with respect to the contents hereof and specifically disclaims any warranties as to merchantability or fitness for any particular purpose. Any of the manufacturer's software described in this manual is sold or licensed `as is'. Should the programs prove defective following their purchase, the buyer (and not the manufacturer, its distributor, or its dealer), assumes the entire cost of all necessary servicing, repair and any incidental or consequential damages resulting from any defect in the software.

The manufacturer of this system is not responsible for any radio and/or TV interference caused by unauthorized modifications to this device. It is the responsibility of the user to correct such interference. The manufacturer is not responsible for any damage incurred in the operation of this system if the correct operational voltage setting was not selected prior to operation. RODUCTION

Page 10 of the Tripp Lite B096-048 user manual — Manual Organization
Page 10 · click to enlarge
Page 10

Please take care to follow the safety precautions below when installing and operating the Console Server:

ƒ Do not remove the metal covers. There are no operator-serviceable components inside. Opening or removing the cover may expose you to dangerous voltage which may cause fire or electric shock. Refer all service to Tripp Lite qualified personnel

ƒ To avoid electric shock the power cord protective grounding conductor must be connected through to ground

ƒ Always pull on the plug, not the cable, when disconnecting the power cord from the socket

ƒ Do not connect or disconnect the Console Server during an electrical storm

ƒ Also it is recommended you use a surge suppressor or UPS to protect the equipment from transients

Manual Organization

This User Manual covers all aspects of installation, configuration and operation and an overview of the information found in the manual is provided below. 1. Introduction An overview of the features of the Console Server and information on this manual

2. Installation Details physical installation of the Console Server and the interconnection of controlled devices
3. System Configuration Describes the initial installation and configuration using the Management Console of the Console Server on the network and the services that will be supported
4. Serial and Network Covers configuring serial ports and connected network hosts, and setting up Users and Groups
5. Failover and OoB dial-in Describes setting up the high-availability access features of the Console Server
6. Secure Tunneling (SDT) Covers secure remote access using SSH and configuring for RDP, VNC, HTTP, HTTPS, etc. access to network and serially connected devices
7. Alerts and Logging Explains the setting up of local and remote event/ data logs and triggering SNMP and email alerts
8. Power & Environment Management of USB, serial and network attached Power Distribution units and UPS units including Network UPS Tool (NUT) operation and IPMI power control. EMD environmental sensor configuration
9. Authentication All access to the Console Server requires usernames and passwords which are locally or externally authenticated
Page 11 of the Tripp Lite B096-048 user manual — Management Console
Page 11 · click to enlarge
Page 11
10. Nagios Integration Setting Nagios central management with SDT extensions and configuring the Console Server as a distributed Nagios server
11. System Management Covers access to and configuration of services to be run on the Console Server
12. Status Reports View the status and logs of serial and network connected devices (ports, hosts, power and environment)
13. Management Includes port controls and reports that can accessed by Users
14. Basic Configuration Command line installation and configuration using the config command
15. Advanced Config More advanced command line configuration activities where you will need to use Linux commands
16. Thin Client Configuration and use of the thin client and other applications (including Power Alert) embedded in the Console Server with PowerAlert (B092016) product

Types of users

The Console Server supports two classes of users:

I. Administrative users: Those who will be authorized to configure and control the Console Server; and to access and control all the connected devices. These administrative users will be set up as members of the admin user group. Any user in this class is referred to generically in this manual as an Administrator. An Administrator can access and control the Console Server using the config utility, the Linux command line or the browser-based Management Console. By default the Administrator has access to all services and ports to control all the serial connected devices and network connected devices (hosts).

II. Users: Embraces those who have been set up by the Administrator with specific limits on their access and control authority. These users are set up as members of the users user group (or some other user groups the Administrator may have added). They are only authorized to perform specified controls on specific connected devices and are referred to as Users. These Users (when authorized) can access serial or network connected devices; and control these devices using the specified services (e.g. Telnet, HHTPS, RDP, IPMI, Serial over LAN, Power Control). An authorized User can also use the Management Console to access configured devices and review port logs.

In this manual, when the term user (lower case) is used, it is referring to both the above classes of users. This document also uses the term remote users to describe users who are not on the same LAN segment as the Console Server. These remote users may be Users, who are on the road connecting to managed devices over the public Internet, or it may be an Administrator in another office connecting to the Console Server itself over the enterprise VPN, or the remote user may be in the same room or the same office but connected on a separate VLAN to the Console Server.

Management Console

The Console Server Management Console runs in a browser. It provides a view of your Console Server Management Switch (B096-016/048) or Console Server with PowerAlert (B092-016) product and all the connected equipment. Administrators can use the Management Console, either locally or from a remote

Page 12 of the Tripp Lite B096-048 user manual — Manual Conventions
Page 12 · click to enlarge
Page 12

location, to configure the Console Server, set up Users, configure the ports and connected hosts, and set up logging and alerts.

Tripp Lite B096-048 — Manual Conventions diagram (page 12)
Fig. 1 · Manual Conventions

An authorized User can use the Management Console to access and control configured devices, review port logs, use the in-built java terminal to access serially attached consoles and control power to connected devices.

The Console Server runs an embedded Linux operating system. Experienced Linux and UNIX users may prefer to undertake configuration at the command line. As an Administrator you can get command line access by connecting through a terminal emulator or communications program to the console serial port; or by SSH or Telnet connecting to the Console Server over the LAN; or by connecting to the Console Server through an SSH tunnel using the SDTConnector.

The B092-016 Console Server also has PowerAlert software and a selection of thin clients embedded (RDP, Firefox etc). You will be able to use these consoles as well as the standard Management Console for access and control.

Tripp Lite B096-048 — Manual Conventions diagram (page 12)
Fig. 2 · Manual Conventions

Manual Conventions

This manual uses different fonts and typefaces to show specific actions:

Page 13 of the Tripp Lite B096-048 user manual — Publishing history Date Revision Update details January 2009 0.9 Initial draft
Page 13 · click to enlarge
Page 13

Text presented like this highlights important issues and it is essential you read and take heed of these warnings

¾ Text presented with an arrow head indent indicates an action you should take as part of the

procedure.

Bold text indicates text that you type, or the name of a screen object (e.g. a menu or button) on the Management Console.

Italic text is also used to indicate a text command to be entered at the command line level.

Publishing history Date Revision Update details January 2009 0.9 Initial draft

February 2009 0.91 Pre-release

Page 14 of the Tripp Lite B096-048 user manual — Network
Page 14 · click to enlarge
Page 14

2. INSTALLATION

Introduction This chapter describes the physical installation of the Console Server hardware and connection to controlled devices 2.1 Models

There are a number of Console Server models, each with a different number of network, USB and serial ports and power supplies: Serial

Network

Console

USB Port

Modem Power

Ports

Ports

Port

B096-048 48 2 1 1 Internal Dual AC Universal Input B096-016 16 2 1 1 Internal Dual AC Universal Input B092-016 16 1 1+KVM 4 - Single AC Universal Input

2.1.1 Kit componentsB096-048 and B096-016 Console Server Management Switch

B096-048 or B096-016 Console Server Management Switch

Tripp Lite B096-048 — Network diagram (page 14)
Fig. 3 · Network

2 x Cable UTP Cat5 blue

Connectors DB9F-RJ45S straight and cross-over

Dual IEC AC power cords

Quick Start Guide and CD-ROM

¾ Unpack your Console Server Management Switch kit and verify you have all the parts shown

above, and that they all appear in good working order

Page 15 of the Tripp Lite B096-048 user manual — 2.2 Power connection
Page 15 · click to enlarge
Page 15

¾ If you are installing your Console Server Management Switch in a rack you will need to attach

the rack mounting brackets supplied with the unit, and install the unit in the rack. Take care to head the Safety Precautions

¾ Connect your Console Server Management Switch to the network, to the serial ports of the

controlled devices, and to power as outlined below

2.1.2 Kit componentsB092-016 Console Server with PowerAlert

B092-016 Console Server with PowerAlert

2 x Cable UTP Cat5 blue

Connector DB9F-RJ45S straight and DB9F- RJ45S cross-over

Quick Start Guide and CD-ROM

¾ Unpack your Console Server and verify you have all the parts shown above, and that they all

appear in good working order

¾ If you are installing your Console Server in a rack, you will need to attach the rack mounting

brackets supplied with the unit, and install the unit in the rack. Take care to heed the Safety Precautions listed earlier

¾ Proceed to connect your B092-016 to the network, to the serial and USB ports of the controlled

devices, to any rack side LCD console or KVM switch, and to power as outlined below

2.2 Power connection

2.2.1 PowerConsole Server Management Switch

The B096-048/16 Console Server Management Switch has dual universal AC power supplies with auto failover built in. These power supplies each accept AC input voltage between 100 and 240 VAC with a frequency of 50 or 60 Hz and the total power consumption per Console Server is less than 30W. Two IEC AC power sockets are located at the rear of the metal case, and these IEC power inlets use conventional IEC AC power cords. A North American power cord is provided by default. Power cords for other regions are available separately from Tripp Lite.

AC power cable

Page 16 of the Tripp Lite B096-048 user manual — 2.4 Serial Port connection
Page 16 · click to enlarge
Page 16
2.2.2 PowerConsole Server with PowerAlert

The standard B092-016 Console Server has a built-in universal auto-switching AC power supply. This power supply accepts AC input voltage between 100 and 240 VAC with a frequency of 50 or 60 Hz and the power consumption is less than 40W.

Tripp Lite B096-048 — 2.3 Network connection diagram (page 16)
Fig. 4 · 2.3 Network connection

The AC power socket is located at the rear of the B092-016. This power inlet uses a conventional AC power cord. A North American power cord is provided by default. Power cords for other regions are available separately from Tripp Lite.

2.3 Network connection

The RJ45 10/100 LAN port is located on the rear of the B092-016 Console Server, and on the front of the B096-048/016 Console Server Management Switch. All physical connections are made using industry standard Cat5e patch cables (Tripp Lite N001 and N002 series cables). Ensure you only connect the LAN port to an Ethernet network that supports 10Base-T/100Base-T. For the initial configuration of the Console Server you must connect a computer to the Console Server’s principal network port.

2.4 Serial Port connection

The RJ45 serial ports are located on the rear of the B092-016 Console Server and on the front of the B096-048/016 Console Server Management Switch. These Console Servers use the RJ45 pinout used by Cisco. Use straight through RJ-45 cabling to connect to equipment such as Cisco, Juniper, SUN, and more.

PIN SIGNAL DEFINITION DIRECTION 1 CTS Clear To Send Input 2 DSR Data Set Ready Input 3 RXD Receive Data Input 4 GND Signal Ground NA 5 GND Signal Ground NA 6 TXD Transmit Data Output 7 DTR Data Terminal Ready Output 8 RTS Request To Send Output Conventional Cat5 cabling with RJ45 jacks are used for serial connections. Before connecting the console port of an external device to the Console Server serial port, confirm that the device supports standard RS-232C (EIA-232).

Tripp Lite B096-048 — 2.4 Serial Port connection diagram (page 16)
Fig. 5 · 2.4 Serial Port connection
Tripp Lite B096-048 — 2.4 Serial Port connection diagram (page 16)
Fig. 6 · 2.4 Serial Port connection
Tripp Lite B096-048 — 2.4 Serial Port connection diagram (page 16)
Fig. 7 · 2.4 Serial Port connection
Page 17 of the Tripp Lite B096-048 user manual — 2.5 USB Port Connection
Page 17 · click to enlarge
Page 17

The Console Server also has a DB9 LOCAL (Console/Modem) port. This DB-9 connector is on the rear panel of the B092-016 Console Server, and on the front panel of the B096-048/016 Console Server Management Switch.

2.5 USB Port Connection

The B096-048/016 Console Server Management Switch has one USB port on the front panel. External USB devices can be plugged into this USB port. The B096-048/016 Console Server Management Switch ships with a USB memory stick so that it will be installed in this port for extended log file storage.

There are four USB 2.0 ports on the rear panel of the B092-016 Console Server. These ports are used to connect to USB consoles (of managed UPS hardware) and to other external devices (such as a USB memory stick or keyboard). External USB devices (including USB hubs) can be plugged into any Console Server USB port. 2.6 Rackmount Console / KVM Connection (B092-016 only)

B092-016 Console Server with PowerAlert can be connected directly to a rack mount console (such as B021-000-17 or B021-019 by Tripp Lite) to provide direct local management right at the rack. Connect the rack mount console’s PS/2 Keyboard/Mouse and VGA connectors directly to the PS/2 and VGA connectors on the B092-016. The default video resolution is 1024 x768. The B092-016 Console Server also supports the use of a USB keyboard/mouse. Alternately, the B092-016 Console Server can also be connected locally to a KVM (or KVMoIP) switch at the rack. The B092-016 Console Server with PowerAlert will enable you then to use this KVM infrastructure to run PowerAlert, to manage your power devices and to run the thin clients to manage other devices. Note Care should be taken in handling all Console Server products. There are no operator-serviceable

components inside, so do not remove cover. Refer any service to qualified personnel

Page 18 of the Tripp Lite B096-048 user manual — 3.1.1 Connected computer set up
Page 18 · click to enlarge
Page 18

3. INITIAL SYSTEM CONFIGURATION

Introduction

This chapter provides step-by-step instructions for the initial configuration of your Console Server and connecting it to your management or operational network. This involves the Administrator:

ƒ Activating the Management Console

ƒ Changing the Administrator password

ƒ Setting the IP address for the Console Server’s principal LAN port

ƒ Selecting the network services to be supported

This chapter also discusses the communications software tools that the Administrator may use to access the Console Server. It also covers the configuration of the additional LAN ports on the B096-016/048 Console Server Management Switch.

3.1 Management Console Connection

Your Console Server has a default IP Address 192.168.0.1 Subnet Mask 255.255.255.0

¾ Directly connect a computer to the Console Server

single computer. However, if you choose to connect your LAN before completing the initial setup steps, it is important that:

ƒ you ensure there are no other devices on the LAN with an address of 192.168.0.1 ƒ the Console Server and the computer are on the same LAN segment, with no interposed router appliances

3.1.1 Connected computer set up

To configure the Console Server with a browser, the connected computer should have an IP address in the same range as the Console Server (e.g. 192.168.0.100):

¾ To configure the IP Address of your Linux or Unix computer simply run ifconfig

¾ For Windows computers (Win9x/Me/2000/XP/ Vista/ NT):

ƒ Click Start -> (Settings ->) Control Panel and double click Network Connections (for 95/98/Me, double click Network).

ƒ Right-click on Local Area Connection and select Properties

ƒ Select Internet Protocol (TCP/IP) and click Properties

ƒ Select Use the following IP address and enter the following details:

Page 19 of the Tripp Lite B096-048 user manual — 3. INITIAL SYSTEM CONFIGURATION
Page 19 · click to enlarge
Page 19
o IP address192.168.0.100
o Subnet mask255.255.255.0

ƒ If you wish to retain your existing IP settings for this network connection, click Advanced and Add the above as a secondary IP connection.

¾ If it is not convenient to change your computer network address, you can use the ARP-Ping

command to reset the Console Server IP address. To do this from a Windows computer:

ƒ Click Start -> Run

ƒ Type cmd and click OK to bring up the command line

ƒ Type arp –d to flush the ARP cache

ƒ Type arp –a to view the current ARP cache which should be empty

Tripp Lite B096-048 — 3. INITIAL SYSTEM CONFIGURATION diagram (page 19)
Fig. 8

Now add a static entry to the ARP table and ping the Console Server to have it get the IP address. In the example below we have a Console Server with a MAC Address 00:13:C6:00:02:0F (designated on the label on the bottom of the unit) and we are setting its IP address to 192.168.100.23. The computer issuing the arp command must be on the same network segment as the Console Server (i.e. have an IP address of 192.168.100.xxx)

ƒ Type arp -s 192.168.100.23 00-13-C6-00-02-0F (Note for UNIX the syntax is: arp -s 192.168.100.23 00:13:C6:00:02:0F)

ƒ Type ping -t 192.18.100.23 to start a continuous ping to the new IP Address.

ƒ Turn on the Console Server and wait for it to configure itself with the new IP address. It will start replying to the ping at this point

ƒ Type arp –d to flush the ARP cache again

3.1.2 Browser connection

¾ Activate your preferred browser on the connected computer and enter https://192.168.0.1 The

Console Server supports all current versions of the popular browsers (Netscape, Internet Explorer, Mozilla Firefox and more)

Page 20 of the Tripp Lite B096-048 user manual — 3. INITIAL SYSTEM CONFIGURATION
Page 20 · click to enlarge
Page 20

¾ You will be prompted to log in. Enter the default

Tripp Lite B096-048 — 3. INITIAL SYSTEM CONFIGURATION diagram (page 20)
Fig. 9

administration username and administration password:

Usernameroot Password: default
Tripp Lite B096-048 — 3. INITIAL SYSTEM CONFIGURATION diagram (page 20)
Fig. 10

The above screen, which lists four initial installation configuration steps, will be displayed:

1. Change the default administration password on the System/Administration page ( Chapter 3 )
2. Configure the local network settings on the System/IP page ( Chapter 3 )
3. Configure port settings and enable the Serial & Network/Serial Port page ( Chapter 4 )
4. Configure users with access to serial ports on the Serial & Network/Users page ( Chapter 3 )

After completing each of the above steps, you can return to the configuration list by clicking in the top left corner of the screen on the logo:

Tripp Lite B096-048 — 3. INITIAL SYSTEM CONFIGURATION diagram (page 20)
Fig. 11

Username / Password were not accepted then reset your Console Server (refer to Chapter 10)

Page 21 of the Tripp Lite B096-048 user manual — 3.2 Administrator Password
Page 21 · click to enlarge
Page 21

3.1.3 Initial B092-016 connection

For the initial configuration of the B092-016 Console Server, you will need to connect a console (keyboard, mouse and display) or a KVM switch directly to its mouse, keyboard and VGA ports. When you initially power on the B092-016, you will be prompted on your directly connected video console to log in

¾ Enter the default administration username and password (Username: root Password: default).

The B092-016 control panel will be displayed

¾ Click the Configure button on the control panel. This will load the Firefox browser and open the

Tripp Lite B096-048 — 3.2 Administrator Password diagram (page 21)
Fig. 12 · 3.2 Administrator Password

¾ At the Management Console menu select System: Administration

3.2 Administrator Password

For security reasons, only the administration user named root can initially log into your Console Server. Only those people who know the root password can access and reconfigure the Console Server itself. However, anyone who correctly guesses the root password (and the default root password which is default) could gain access. It is therefore essential that you enter and confirm a new root password before giving the Console Server any access to, or control of, your computers and network appliances.

B092-016 Management Console

Page 22 of the Tripp Lite B096-048 user manual — 3.3 Network IP address
Page 22 · click to enlarge
Page 22
¾ Select SystemAdministration

¾ Enter a new System Password then re-enter it in Confirm System Password. This is the new

password for root, the main administrative user account, so it is important that you choose a complex password, and keep it safe

¾ You may now wish to enter a System Name and System Description for the Console Server to

give it a unique ID and make it simple to identify

¾ Click Apply. As password has been changed, you will be prompted to log in again. This time use

firmware, you can upgrade. Refer to Upgrade Firmware - Chapter 10

3.3 Network IP address

It is time to enter an IP address for the principal 10/100 LAN port on the Console Server; or enable its DHCP client so that it automatically obtains an IP address from a DHCP server on the network to which it is to be connected.

¾ On the SystemIP menu select the Network Interface page then check DHCP or static for the

¾ If you select static you must manually enter the new IP Address, Subnet Mask, Gateway and

DNS server details. This selection automatically disables the DHCP client

the new password · Configuration Method

Page 23 of the Tripp Lite B096-048 user manual — 3.3 Network IP address
Page 23 · click to enlarge
Page 23
Tripp Lite B096-048 — 3.3 Network IP address diagram (page 23)
Fig. 13 · 3.3 Network IP address

¾ If you select DHCP, the Console Server will look for configuration details from a DHCP server on

your management LAN. This selection automatically disables any static address. The Console Server MAC address can be found on a label on the base plate

DHCP client enabled, so it automatically accepts any network IP address assigned by a DHCP server on your network. In this initial state, the Console Server will then respond to both its Static address (192.168.0.1) and its newly assigned DHCP address

¾ By default, the Console Server 10/100 LAN port auto detects the Ethernet connection speed.

However you can use the Media menu to lock the Ethernet to 10 Mb/s or 100Mb/s and to Full Duplex (FD) or Half Duplex (HD)

so it has an IP address that is in the same network range as this new address (as detailed in an earlier note in this chapter)

¾ You will need to reconnect the browser on the Computer that is connected to the Console

Server by entering http://new IP address

3.3.1 IPv6 configuration

By default, the Console Server Ethernet interfaces support IPv4, however, they can also be configured for IPv6 operation:

¾ On the SystemIP menu select General Settings page and check Enable IPv6

¾ Click Apply

Page 24 of the Tripp Lite B096-048 user manual — 3.4 System Services
Page 24 · click to enlarge
Page 24
Tripp Lite B096-048 — 3.4 System Services diagram (page 24)
Fig. 14 · 3.4 System Services

¾ You will then need to configure the IPv6 parameters on each interface page

Tripp Lite B096-048 — 3.4 System Services diagram (page 24)
Fig. 15 · 3.4 System Services

3.4 System Services

The Administrator has a selection of access protocols that can be used to access the Console Server. The factory default enables HTTPS and SSH access to the Console Server and disables HTTP and Telnet. The User can also use the nominated services for limited access to the Console Server itself. The Administrator can configure the services to be enabled:

Tripp Lite B096-048 — 3.4 System Services diagram (page 24)
Fig. 16 · 3.4 System Services
Page 25 of the Tripp Lite B096-048 user manual — 3.4 System Services
Page 25 · click to enlarge
Page 25
¾ Select SystemServices . Then select /deselect the service to be enabled /disabled. The following

access protocol options are available:

HTTPS Ensures secure browser access to all the Management Console menus. It also allows appropriately configured Users secure browser access to selected Management Console Manage menus. If HTTPS is enabled, the Administrator will be able to use a secure browser connection to the Console Server’s Management Console. For information on certificate and user/client software configuration, refer to Chapter 9 - Authentication. By default, HTTPS is enabled, and it is recommended that only HTTPS access be used if the Console Server is to be managed over any public network (e.g. the Internet).

HTTP Allows the Administrator basic browser access to the Management Console. It is recommended that you disable the HTTP service if the Console Server is to be remotely accessed over the Internet.

Telnet Gives the Administrator Telnet access to the system command line shell (Linux commands). While this may be suitable for a local direct connection over a management LAN, it is recommended this service be disabled if the Console Server is to be remotely administered.

SSH Provides secure SSH access to the Linux command line shell. It is recommended you choose SSH as the protocol when the Administrator is connecting to the Console Server over the Internet or over any other public network. This will provide authenticated communications between the SSH client program on the remote Computer and the SSH sever in the Console Server. For more information on SSH configuration, refer to Chapter 9 - Authentication.

Tripp Lite B096-048 — 3.4 System Services diagram (page 25)
Fig. 17 · 3.4 System Services
Page 26 of the Tripp Lite B096-048 user manual — 3.4 System Services
Page 26 · click to enlarge
Page 26

¾ There are also a number of related service options that can be configured at this stage:

SNMP Enables netsnmp in the Console Server which will keep a remote log of all posted information. SNMP is disabled by default. To modify the default SNMP settings, the Administrator must make the edits at the command line as described in Chapter 15 – Advanced Configuration

TFTP The Console Servers set up default TFTP server on the USB flash card. This server can be used to store config files, maintain access and transaction logs, etc.

Ping Allows the Console Server to respond to incoming ICMP echo requests. Ping is enabled by default, however, for security reasons this service should generally be disabled post initial configuration

¾ And there are some serial port access parameters that can be configured on this menu:

Base The Console Server uses specific default ranges for the TCP/IP ports for the various access services that Users and Administrators can use to access devices attached to serial ports (as covered in Chapter 4 – Configuring Serial Ports). The Administrator can also set alternate ranges for these services, and these secondary ports will then be used in addition to the defaults.

The default TCP/IP base port address for Telnet access is 2000, and the range for Telnet is IP Address: Port (2000 + serial port #) i.e. 2001 – 2048. So if the Administrator were to set 8000 as a secondary base for Telnet then serial port #2 on the Console Server can be Telnet accessed at IP Address: 2002 and at IP Address: 8002.

The default base for SSH is 3000; for Raw TCP is 4000; for RFC2217 it is 5000 and for Unauthenticated Telnet it is 6000.

¾ The B092-016 Console Server with PowerAlert also presents some additional service and

configuration options:

VNC The B092-016 Console Server has an internal VNC server. When enabled, it allows remote users to connect to the Console Server and run the PowerAlert software and any other embedded thin client programs as if they were plugged in locally to the KVM connectors on the B092-016 (refer to Chapter 16 for more details). Users connect using port 5900 and need to run a VNC client applet

Secure VNC This enables a secure encrypted remote connection using VNC over SSL on port

5800 to the B092-016 Console Server (refer to Chapter 16)

PowerAlert This configuration option will automatically start the PowerAlert application on

the B092-016 and display the console as soon as you log into the local display or VNC session (refer to Chapter 16). The complete PowerAlert manual can be downloaded at www.tripplite.com/EN/support/PowerAlert/Downloads.cfm

Page 27 of the Tripp Lite B096-048 user manual — 3.5 Communications Software
Page 27 · click to enlarge
Page 27
Tripp Lite B096-048 — 3.5 Communications Software diagram (page 27)
Fig. 18 · 3.5 Communications Software

¾ Click Apply. As you apply your services selections, the screen will be updated with a

confirmation message:

Message Changes to configuration succeeded.

3.5 Communications Software

You need to configure the access protocols that the communications software on the Administrator and User Computer will use when connecting to the Console Server (and when connecting to serial devices and network hosts which are attached to the Console Server).

This section provides an overview of the communications software tools that can be used on the remote computer. Tripp Lite recommends the SDT Connector software tool that is provided with the Console Server, however, generic tools such as PuTTY and SSHTerm may also be used. 3.5.1 SDT Connector

We recommend using the SDT Connector communications software for all communications with Console Servers. Each Console Server is supplied with an unlimited number of SDT Connector licenses to use with that Console Server.

SDT Connector is a lightweight tool that enables Users and Administrators to securely access the Console Server, and the various computers, network devices and appliances that may be serially or network- connected to the Console Server.

SDT Connector can be installed on Windows 2000, XP, 2003, Vista and on most Linux, UNIX and Solaris computers as detailed in Chapter 7.

3.5.2 PuTTY

Communications packages like PuTTY can be also used to connect to the Console Server command line (and to connect to serially attached devices as covered in Chapter 4). PuTTY is a freeware implementation of Telnet and SSH for Win32 and UNIX platforms. It runs as an executable application without needing to be installed onto your system. PuTTY (the Telnet and SSH client itself) can be downloaded at http://www.tucows.com/preview/195286.html

Page 28 of the Tripp Lite B096-048 user manual — 3.5 Communications Software
Page 28 · click to enlarge
Page 28
Tripp Lite B096-048 — 3.5 Communications Software diagram (page 28)
Fig. 19 · 3.5 Communications Software

ƒ To use PuTTY for an SSH terminal session from a Windows client, enter the Console Server’s IP address as the ‘Host Name (or IP address)’

ƒ To access the Console Server command line, select ‘SSH’ as the protocol and use the default IP Port 22

ƒ Click ‘Open’ and the Console Server login prompt will appear. (You may also receive a ‘Security Alert’ that the host’s key is not cached. Choose ‘yes’ to continue.)

ƒ Using the Telnet protocol is similarly simple, but you need to use the default port 23

3.5.3 SSHTerm

Another common communications package that may be useful is SSHTerm. This is an open source package that can be downloaded from http://sourceforge.net/projects/sshtools

Tripp Lite B096-048 — 3.5 Communications Software diagram (page 28)
Fig. 20 · 3.5 Communications Software

ƒ To use SSHTerm for an SSH terminal session from a Windows Client, simply Select the ‘File’ option and click on ‘New Connection’.

ƒ A new dialog box will appear for your ‘Connection Profile’. Type in the host name or IP address (for the Console Server unit) and the TCP port that the SSH session will use (port 22). Then type in your username and choose password authentication and click Connect.

Page 29 of the Tripp Lite B096-048 user manual — 3.6 Management Network Configuration (B096-048/016 only)
Page 29 · click to enlarge
Page 29
Tripp Lite B096-048 — 3.6 Management Network Configuration (B096-048/016 only) diagram (page 29)
Fig. 21 · 3.6 Management Network Configuration (B096-048/016 o…

ƒ A message may appear about the host key fingerprint. You will need to select ‘Yes’ or ‘Always’ to continue.

ƒ The next step is password authentication. You will be prompted for your username and password from the remote system. You will then be logged on to the Console Server

3.6 Management Network Configuration (B096-048/016 only)

The B096-048/016 Console Server Management Switches have a second Ethernet network port that can be configured as a management Console Server/LAN port or as a failover/OoB access port.

3.6.1 Configure Management Switch as a Management LAN gateway

The Management Switch in the B096-048/016 Console Servers can be configured to provide a management LAN gateway. With this configuration, the B096-048/016 provides firewall, router and DHCP server features and you can connect managed hosts to this management LAN.

Tripp Lite B096-048 — 3.6 Management Network Configuration (B096-048/016 only) diagram (page 29)
Fig. 22 · 3.6 Management Network Configuration (B096-048/016 o…

These features are all disabled by default. To configure the Management LAN gateway:

¾ Select the Management LAN page on the System: IP menu and uncheck Disable

¾ Configure the IP Address and Subnet Mask for the Management LAN (leaving the Gateway and

DNS fields blank) then click Apply

¾ The management LAN gateway function is now enabled with default firewall and router rules.

These rules can be reconfigured at the command line.

Page 30 of the Tripp Lite B096-048 user manual — 3.6 Management Network Configuration (B096-048/016 only)
Page 30 · click to enlarge
Page 30
Tripp Lite B096-048 — 3.6 Management Network Configuration (B096-048/016 only) diagram (page 30)
Fig. 23 · 3.6 Management Network Configuration (B096-048/016 o…

gateway port or it can be configured as an OoB/Failover port - but not both. So be sure that you did not allocate Management LAN as the Failover Interface when you configured the principal Network connection on the System: IP menu

The B096-048/016 Console Server Management Switches also host a DHCP server which by default is set at disabled. The DHCP server enables the automatic distribution of IP addresses to hosts running DHCP clients on the Management LAN. To enable the DHCP server:

¾ On the SystemIP menu select the Management LAN page and click the Disabled label in the

DHCP Server field; or go to the System: DHCP Server menu and check Enable DHCP Server

Page 31 of the Tripp Lite B096-048 user manual — 3.6 Management Network Configuration (B096-048/016 only)
Page 31 · click to enlarge
Page 31
Tripp Lite B096-048 — 3.6 Management Network Configuration (B096-048/016 only) diagram (page 31)
Fig. 24 · 3.6 Management Network Configuration (B096-048/016 o…

To configure the DHCP server for the Management LAN:

¾ Enter the Gateway address that is to be issued to the DHCP clients. If this field is left blank, the

IP address of the B096-048/016 will be used

¾ Enter the Primary DNS and Secondary DNS address to issue the DHCP clients. Again if this field

is left blank, the IP address of the B096-048/016 is used, so leave this field blank for automatic DNS server assignment

¾ Optionally enter a Domain Name suffix to issue DHCP clients

¾ Enter the Default Lease time and Maximum Lease time in seconds. The lease time is the time

that a dynamically assigned IP address is valid before the client must request it again

The DHCP server will sequentially issue IP addresses from a specified address pool(s):

¾ Click Add in the Dynamic Address Allocation Pools field

¾ Enter the DHCP Pool Start Address and End Address and click Apply

The DHCP server also supports pre-assigning IP addresses to be allocated only to specific MAC addresses and reserving IP addresses to be used by connected hosts with fixed IP addresses. To reserve an IP addresses for a particular host:

¾ Click Add in the Reserved Addresses field

¾ Enter the Hostname, the Hardware Address (MAC) and the Statically Reserved IP address for

the DHCP client and click Apply

¾ Click Apply

Page 32 of the Tripp Lite B096-048 user manual — 3.6 Management Network Configuration (B096-048/016 only)
Page 32 · click to enlarge
Page 32

Once DHCP has initially allocated hosts addresses, it is recommended to copy these into the pre- assigned list so the same IP address will be reallocated in the event of a reboot.

3.6.3 Configure Management Switch for Failover or Broadband OoB

The Management Switch in the B096-048/016 Console Server can be configured to provide a failover option. In the event of a problem using the main LAN connection for accessing the Console Server, an alternate access path is used.

Tripp Lite B096-048 — 3.6 Management Network Configuration (B096-048/016 only) diagram (page 32)
Fig. 25 · 3.6 Management Network Configuration (B096-048/016 o…

¾ By default, the failover is not enabled. To enable, select the Network page on the System: IP

¾ Now select the Failover Interface to be used in the event of an outage on the main network.

This can be:

o an alternate broadband Ethernet connection or

o the B096-048/016 internal modem or

o an external serial modem/ISDN device connected to the B096-048/016 console port (for

out-dialing to an ISP or the remote management office)

Tripp Lite B096-048 — 3.6 Management Network Configuration (B096-048/016 only) diagram (page 32)
Fig. 26 · 3.6 Management Network Configuration (B096-048/016 o…

¾ Click Apply. You have selected the failover method. However, it is not active until you have

specified the external sites to be probed to trigger failover and set up the failover ports themselves. This is covered in Chapter 5.

gateway port or it can be configured as an OoB/Failover port - but not both. So ensure you did not configure this port as the Management LAN on the System: IP menu

menu

Page 33 of the Tripp Lite B096-048 user manual — 4.1 Configuring Serial Ports
Page 33 · click to enlarge
Page 33

4. SERIAL PORT AND NETWORK HOST

Introduction

The Console Server enables access and control of serially-attached devices and network-attached devices (hosts). The Administrator must configure access privileges for each of these devices, and specify the services that can be used to control the devices. The Administrator can also set up new users and specify each user’s individual access and control privileges.

This chapter covers each of the steps in configuring hosts and serially attached devices:

Configure Serial Ports – setting up the protocols to be used in accessing serially-connected devices

Users & Groups – setting up users and defining the access permissions for each of these users

Authentication – covered in Chapter 9

Network Hosts – configuring access to local network connected computers or appliances (referred to as hosts)

Cascading and Redirection of Serial Console Ports

Connecting to Power (UPS, PDU and IPMI) and Environmetal Monitoring (EMD) devices

4.1 Configuring Serial Ports

To configure a serial port you must first set the Common Settings (Chapter 4.1.1) that are to be used for the data connection to that port (e.g. baud rate) and the mode the port is to operate in. Each port can be set to support one of five operating modes:

i. Console Server Mode (Chapter 4.1.2) is the default setting and enables general access to the serial console port on serially attached devices

ii. Device Mode (Chapter 4.1.3) sets the serial port up to communicate with an intelligent serial controlled PDU, UPS or Environmental Monitor Devices (EMD)

iii. SDT Mode (Chapter 4.1.4) enables graphical console access (with RDP, VNC, HTTPS etc) to hosts that are serially connected

iv. Terminal Server Mode (Chapter 4.1.5) sets the serial port to await an incoming terminal login session

v. Serial Bridge Mode (Chapter 4.1.6) enables the transparent interconnection of two serial port devices over a network

To select the serial port to configure:

¾ Select Serial & NetworkSerial Port and click Edit on the port to be reconfigured

Ports and select which ports you wish to configure as a group

Configuring Trusted Networks

Page 34 of the Tripp Lite B096-048 user manual — 4. SERIAL PORT AND NETWORK HOST
Page 34 · click to enlarge
Page 34
Tripp Lite B096-048 — 4. SERIAL PORT AND NETWORK HOST diagram (page 34)
Fig. 27

¾ When you have configured the common settings and the mode for each port, set up any remote

syslog (Chapter 4.1.7), then click Apply

¾ If the Console Server has been configured with distributed Nagios monitoring enabled then you

will also be presented with Nagios Settings options to enable nominated services on the Host to be monitored (refer to Chapter 10 – Nagios Integration)

4.1.1 Common Settings

There are a number of common settings available for each serial port. These are independent of the mode in which the port is being used. These serial port parameters must be set so they match the serial port parameters on the device which is attached to that port:

¾ Specify a label for the port

¾ Select the appropriate Baud Rate, Parity, Data Bits, Stop Bits and Flow Control for each port

(and ensure they match the settings for serial device that is connected). The Signaling Protocol is hard configured to be RS232

Console Server Mode. The baud rate can be changed to 2400 – 230400 baud using the management console. Lower baud rates (50, 75, 110, 134, 150, 200, 300, 600, 1200, 1800 baud) can be configured from the command line as detailed in Chapter 14

Page 35 of the Tripp Lite B096-048 user manual — 4. SERIAL PORT AND NETWORK HOST
Page 35 · click to enlarge
Page 35
Tripp Lite B096-048 — 4. SERIAL PORT AND NETWORK HOST diagram (page 35)
Fig. 28

4.1.2 Console Server Mode

Select Console Server Mode to enable remote management access to the serial console that is attached to the serial port:

Tripp Lite B096-048 — 4. SERIAL PORT AND NETWORK HOST diagram (page 35)
Fig. 29

Logging Level This specifies the level of information to be logged and monitored (refer to Chapter 7 -

Alerts and Logging)

Page 36 of the Tripp Lite B096-048 user manual — 4. SERIAL PORT AND NETWORK HOST
Page 36 · click to enlarge
Page 36

Telnet Check to enable Telnet access to the serial port. When enabled, a Telnet client on a User or

Administrator’s computer can connect to a serial device attached to this serial port on the Console Server. The default port address is IP Address _ Port (2000 + serial port #) i.e. 2001 – 2048

Telnet communications are unencrypted, so this protocol is generally recommended for local connections only. However, if the remote communications are being tunneled with SDT Connector, then Telnet can be used to securely access these attached devices (see Note below).

With Win2000/XP/NT you can run Telnet from the command prompt (cmd.exe). Vista comes with a Telnet client and server but they are not enabled by default. To enable Telnet, simply:

ƒ Log in as Admin and go to Start/ Control Panel/Programs and Features

ƒ Select Turn Windows Features On or Off, check the Telnet Client and click OK

Tripp Lite B096-048 — 4. SERIAL PORT AND NETWORK HOST diagram (page 36)
Fig. 30

Telnet connections that are SSH tunneled from their client computers to the serial port on the Console Server with a simple point-and-click.

To use SDT Connector to access consoles on the Console Server serial ports, configure the SDT Connector with the Console Server as a gateway, then as a host. Now enable Telnet service on Port (2000 + serial port #) i.e. 2001–2048. Refer to Chapter 6 for more details on using SDT Connector for Telnet and SSH access to devices attached to the Console Server serial ports.

You can also use standard communications packages like PuTTY to set a direct Telnet (or SSH) connection to the serial ports (refer Note below):

the Console Server’s IP address as the ‘Host Name (or IP address)’. Select ‘Telnet’ as the protocol and set the ‘TCP port’ to 2000 plus the physical serial port number (i.e. 2001 to 2048).

Click the ‘Open’ button. You may then receive a ‘Security Alert’ that the host’s key is not cached. Choose ‘yes’ to continue. You will then be presented with the login prompt of the remote system connected to the serial port chosen on the Console Server. You can login as normal and use the host serial console screen.

Page 37 of the Tripp Lite B096-048 user manual — 4. SERIAL PORT AND NETWORK HOST
Page 37 · click to enlarge
Page 37
Tripp Lite B096-048 — 4. SERIAL PORT AND NETWORK HOST diagram (page 37)
Fig. 31

PuTTY can be downloaded at http://www.tucows.com/preview/195286.html

SSH It is recommended that the User or Administrator uses SSH as the protocol for connecting to serial consoles attached to the Console Server when communicating over the Internet or any other public network. This will provide an authenticated, encrypted connection between the SSH client program on the remote user’s computer and the Console Server. The user’s communication with the serial device attached to the Console Server is therefore secure.

It is recommended for Users and Administrators to use SDT Connector when making an SSH connection to the consoles on devices attached to the Console Server’s serial ports. Configure the SDT Connector with the Console Server as a gateway, then as a host, and enable SSH service on Port (3000 + serial port #) i.e. 3001-3048 (refer to Chapter 6).

You can also use common communications packages, like PuTTY or SSHTerm to SSH connect directly to port address IP Address _ Port (3000 + serial port #) i.e. 3001–3048.

Alternately SSH connections can be configured using the standard SSH port 22. The serial port being accessed is then identified by appending a descriptor to the username. This syntax supports any of:

<username>:<portXX>

<username>:<port label>

<username>:<ttySX>

<username>:<serial>

So for a user named 'fred' to access serial port 2, when setting up the SSHTerm or the PuTTY SSH client, instead of typing username = fred and ssh port = 3002, the alternate is to type username = fred:port02 (or username = fred:ttyS1) and ssh port = 22.

Or, by typing username=fred:serial and ssh port = 22, the user is presented with a port selection option:

Page 38 of the Tripp Lite B096-048 user manual — 4. SERIAL PORT AND NETWORK HOST
Page 38 · click to enlarge
Page 38
Tripp Lite B096-048 — 4. SERIAL PORT AND NETWORK HOST diagram (page 38)
Fig. 32

This syntax enables users to set up SSH tunnels to all serial ports with only a single IP port 22 having to be opened in their firewall/gateway.

TCP RAW TCP allows connections directly to a TCP socket. Communications programs such as PuTTY also support RAW TCP, however, this protocol would usually be used by a custom application. For RAW TCP, the default port address is IP Address _ Port (4000 + serial port #) i.e. 4001 – 4048.

RAW TCP also enables the serial port to be tunneled to a remote Console Server, so two serial port devices can be transparently interconnected over a network (see Chapter 4.1.6 – Serial Bridging).

RFC2217 Selecting RFC2217 enables serial port redirection on that port. For RFC2217, the default port

address is IP Address _ Port (5000 + serial port #) i.e. 5001 – 5048.

You will also need to run serial port redirector software on your desktop computer. This software, which supports RFC2217 virtual com ports, is available commercially and as freeware, for Windows UNIX and Linux, and it allows you to use a serial device connected to the remote Console Server as if it were connected to your local serial port.

Unauthenticated Telnet Selecting Unauthenticated Telnet enables Telnet access to the serial port

without requiring the user to provide credentials. When a user accesses the Console Server to Telnet to a serial port they are normally given a login prompt. However, with unauthenticated Telnet, they connect directly through to port with any Console Server login at all. This mode is mainly used when you have an external system (such as conserver) managing user authentication and access privileges at the serial device level.

For Unauthenticated Telnet, the default port address is IP Address _ Port (6000 + serial port #) i.e. 6001 – 6048.

Accumulation Period By default, once a connection has been established for a particular serial port

(such as a RFC2217 redirection or Telnet connection to a remote computer), then any incoming characters on that port are forwarded over the network on a character by character basis. The accumulation period changes this by specifying a period of time that incoming characters will be collected before being sent as a packet over the network

Escape Character This enables you to change the character used for sending escape characters. The

default is ~.

Single Connection This setting limits the port to a single connection, so if multiple users have access

privileges for a particular port, only one user at a time can be accessing that port (i.e. port “snooping” is not permitted).

Page 39 of the Tripp Lite B096-048 user manual — 4. SERIAL PORT AND NETWORK HOST
Page 39 · click to enlarge
Page 39

4.1.3 SDT Mode

This setting allows port forwarding of LAN protocols such as RDP, VNC, HTPP, HTTPS, SSH and Telnet through to computers which are connected locally to the Console Server by their serial COM port. However such port forwarding requires a PPP link to be set up over this serial port.

Tripp Lite B096-048 — 4. SERIAL PORT AND NETWORK HOST diagram (page 39)
Fig. 33

Refer to Chapter 6.6 - Using SDT Connector to Telnet or SSH connect to devices that are serially attached to the Console Server for configuration details

4.1.4 Device (RPC, UPS, EMD) Mode

This mode configures the selected serial port to communicate with a serial controlled Uninterruptible Power Supply (UPS), serial Remote Power Controller/ Power Distribution Unit (RPC) or Environmental Monitoring Device (EMD)

Tripp Lite B096-048 — 4. SERIAL PORT AND NETWORK HOST diagram (page 39)
Fig. 34

¾ Select the desired Device Type (UPS, RPC or EMD)

¾ Proceed to the appropriate device configuration page (Serial & Network: UPS Connections, RPC

Connection or Environmental) as detailed in Chapter 8 - Power & Environmental Management)

¾ The B092-016 Console Server also allows you to configure ports as UPS devices that PowerAlert

will manage. PowerAlert will discover the attached UPS device and auto-configure. See www.tripplite.com/EN/support/PowerAlert/Downloads.cfm for a complete PowerAlert manual.

Tripp Lite B096-048 — 4. SERIAL PORT AND NETWORK HOST diagram (page 39)
Fig. 35

4.1.5 Terminal Server Mode

¾ Select Terminal Server Mode and the Terminal Type (vt220, vt102, vt100, Linux or ANSI) to

enable a getty on the selected serial port.

Page 40 of the Tripp Lite B096-048 user manual — 4. SERIAL PORT AND NETWORK HOST
Page 40 · click to enlarge
Page 40
Tripp Lite B096-048 — 4. SERIAL PORT AND NETWORK HOST diagram (page 40)
Fig. 36

The getty will then configure the port and wait for a connection to be made. An active connection on a serial device is usually indicated by the Data Carrier Detect (DCD) pin on the serial device being raised. When a connection is detected, the getty program issues a login: prompt, and then invokes the login program to handle the actual system login.

logged for alerts etc.

4.1.6 Serial Bridging Mode

With serial bridging, the serial data on a nominated serial port on one Console Server is encapsulated into network packets and then transported over a network to a second Console Server, where it is then represented as serial data. So the two Console Servers effectively act as a virtual serial cable over an IP network.

One Console Server is configured to be the Server. The Server serial port to be bridged is set in Console Server mode with either RFC2217 or RAW enabled (as described in Chapter 4.1.2 – Console Server Mode).

For the Client Console Server, the serial port to be bridged must be set in Bridging Mode:

Tripp Lite B096-048 — 4. SERIAL PORT AND NETWORK HOST diagram (page 40)
Fig. 37

¾ Select Serial Bridging Mode and specify the IP address of the Server Console Server and the TCP

port address of the remote serial port (for RFC2217 bridging this will be 5001-5048)

¾ By default, the bridging client will use RAW TCP so you must select RFC2217 if this is the Console

Server mode you have specified on the server Console Server

Page 41 of the Tripp Lite B096-048 user manual — 4.2 Add/Edit Users
Page 41 · click to enlarge
Page 41
Tripp Lite B096-048 — 4.2 Add/Edit Users diagram (page 41)
Fig. 38 · 4.2 Add/Edit Users

¾ You may secure the communications over the local Ethernet by enabling SSH however you will

need to generate and upload keys (refer to Chapter 14 – Advanced Configuration)

4.1.7 Syslog

In addition to built-in logging and monitoring (which can be applied to serial-attached and network- attached management accesses, as covered in Chapter 7 - Alerts and Logging), the Console Server can also be configured to support the remote syslog protocol on a per serial port basis:

¾ Select the Syslog Facility/Priority fields to enable logging of traffic on the selected serial port to

a syslog server; and to appropriately sort and action those logged messages (i.e. redirect them/ send alert email etc.)

Tripp Lite B096-048 — 4.2 Add/Edit Users diagram (page 41)
Fig. 39 · 4.2 Add/Edit Users

For example if the computer attached to serial port 3 should never send anything out on its serial console port, the Administrator can set the Facility for that port to local0 (local0 .. local7 are meant for site local values), and the Priority to critical. At this priority, if the Console Server syslog server does receive a message, it will automatically raise an alert. Refer to Chapter 7.

4.2 Add/Edit Users

The Administrator uses this menu selection to set up, edit and delete users and to define the access permissions for each of these users.

Page 42 of the Tripp Lite B096-048 user manual — 4.2 Add/Edit Users
Page 42 · click to enlarge
Page 42
Tripp Lite B096-048 — 4.2 Add/Edit Users diagram (page 42)
Fig. 40 · 4.2 Add/Edit Users

Users can be authorized to access specified Console Server serial ports and specified network-attached hosts. These users can also be given full Administrator status (with full configuration and management and access privileges).

To simplify user setup, they can be configured as members of Groups. There are two Groups set up by default (admin and user).

1. Membership of the admin group provides the user with full Administrator privileges. The admin user (referred to in this manual as Administrator) can access the Console Server using any of the services which have been enabled in System: Services e.g. if only HTTPS has been enabled then the Administrator can only access the Console Server using HTTPS. However, once logged in, they can reconfigure the Console Server settings (e.g. to enabled HTTP/Telnet for future access). They can also access any of the connected Hosts or serial port devices using any of the services that have been enabled for these connections. However, since the Administrator can reconfigure the access services for any Host or serial port, only trusted users should have Administrator access.

checked serial ports and checked hosts only, even for admin group users. 2. Membership of the user group provides the user with limited access to the Console Server and connected Hosts and serial devices. These Users can access only the Management section of the Management Console menu and they have no command line access to the Console Server. They also can only access those Hosts and serial devices that have been checked for them, using services that have been enabled.

3. The Administrator can also set up additional Groups with specific serial port and host access permissions (same as Users). However users in these additional groups don’t have any access to the Management Console menu nor to any command line access to the Console Server itself. Lastly the Administrator can also set up users who are not a member of any Groups and they will have the same access as users in the additional groups.

To set up new users and classify them as members of particular Groups:

Page 43 of the Tripp Lite B096-048 user manual — 4.2 Add/Edit Users
Page 43 · click to enlarge
Page 43
¾ Select Serial & NetworkUsers & Groups to display the configured Groups and Users

¾ Click Add Group to add a new Group

Tripp Lite B096-048 — 4.2 Add/Edit Users diagram (page 43)
Fig. 41 · 4.2 Add/Edit Users

¾ Add a Group name and Description for each new Group, then nominate Accessible Hosts and

Accessible Ports to specify the serial ports and hosts you wish any users in this new Group to be able to access

¾ Select Serial & NetworkUsers to display the configured users

¾ Click Add User to add a new user

Tripp Lite B096-048 — 4.2 Add/Edit Users diagram (page 43)
Fig. 42 · 4.2 Add/Edit Users

¾ Click Apply

Page 44 of the Tripp Lite B096-048 user manual — 4.4 Network Hosts
Page 44 · click to enlarge
Page 44

¾ Add a Username and a confirmed Password for each new User. You may also include

information related to the user (e.g. contact details) in the Description field

¾ Nominate Accessible Hosts and Accessible Ports to specify which serial ports and which LAN

connected hosts you wish the user to have access to

¾ Specify which Group (or Groups) you wish the user to be a member of.

Your new user will now be able to access the nominated network devices and the devices attached to the nominated serial ports.

per serial port or host. Multiple users (Users and Administrators) can control/monitor one port or host. Similarly there are no specific limits on the number of Groups and each user can be a member of a number of Groups (in which case they take on the cumulative access privileges of each of those Groups). A user does not have to be a member of any Groups (but if the User is not even a member of the default user group then they will not be able to use the Management Console to manage ports).

The Administrator can also edit the access settings for any existing users:

¾ Select Serial & NetworkUsers & Groups and click Edit for the User to be modified

4.3 Authentication

Refer to Chapter 9.1 - Remote Authentication Configuration for authentication configuration details

4.4 Network Hosts

To access a locally networked computer or appliances (referred to as a Host), you must identify the network connected Host; and then specify the TCP or UDP ports/services that are permitted to be used for communicating to that Host:

Tripp Lite B096-048 — 4.4 Network Hosts diagram (page 44)
Fig. 43 · 4.4 Network Hosts

¾ Click Apply

Page 45 of the Tripp Lite B096-048 user manual — 4.3 Authentication
Page 45 · click to enlarge
Page 45
¾ Selecting Serial & NetworkNetwork Hosts presents all the network connected Hosts that have

been enabled for access, and the related access TCP ports/services

¾ Click Add Host to enable access to a new Host (or select Edit to update the settings for existing

Tripp Lite B096-048 — 4.3 Authentication diagram (page 45)
Fig. 44 · 4.3 Authentication

¾ Enter the IP Address or DNS Name of the new network connected Host (and optionally enter a

¾ Add or edit the Permitted Services (or TCP/UDP port numbers) that are authorized to be used in

controlling this host. Only these permitted services will be port forwarded through to the Host. All other services (TCP/UDP ports) will be blocked.

¾ If the Console Server has been configured with distributed Nagios monitoring enabled then you

will also be presented with Nagios Settings options to enable nominated services on the Host to be monitored (refer to Chapter 10 – Nagios Integration)

¾ The Logging Level specifies the level of information to be logged and monitored for each Host

access (refer to Chapter 7 - Alerts and Logging)

¾ If the Host is a networked server with IPMI power control, then the Administrator can enable

users (Users and Administrators) to remotely cycle power and reboot (refer to Chapter 8.2 - Configuring IPMI Power Management)

Host) · Description) · ¾ Click Apply

Page 46 of the Tripp Lite B096-048 user manual — 4.5 Trusted Networks
Page 46 · click to enlarge
Page 46

4.5 Trusted Networks

The Trusted Networks facility gives you the option to nominate specific IP addresses that users (Administrators and Users) must be located at in order to have access to Console Server serial ports:

Tripp Lite B096-048 — 4.5 Trusted Networks diagram (page 46)
Fig. 45 · 4.5 Trusted Networks
¾ Select Serial & NetworkTrusted Networks

¾ To add a new trusted network, select Add Rule

Tripp Lite B096-048 — 4.5 Trusted Networks diagram (page 46)
Fig. 46 · 4.5 Trusted Networks

¾ Select the Accessible Port(s) that the new rule is to be applied to

¾ Then enter the Network Address of the subnet to be permitted access

¾ Then specify the range of addresses that are to be permitted by entering a Network Mask for

that permitted IP range e.g.

ƒ To permit all the users located with a particular Class C network (204.15.5.0 say) connection to the nominated port, add the following Trusted Network New Rule:

Network IP Address 204.15.5.0

Subnet Mask 255.255.255.0

ƒ If you want to permit only the one user who is located at a specific IP address (204.15.5.13 say) to connect:

Page 47 of the Tripp Lite B096-048 user manual — 4.6 Serial Port Cascading
Page 47 · click to enlarge
Page 47

Network IP Address 204.15.5.0

Subnet Mask 255.255.255.255

ƒ If however you want to allow all the users operating from within a specific range of IP addresses (say any of the thirty addresses from 204.15.5.129 to 204.15.5.158) to be permitted connection to the nominated port:

Host /Subnet Address 204.15.5.128

Subnet Mask 255.255.255.224

ports. However they do not restrict access by the Administrator to the Console Server itself or to attached hosts. To change the default settings for this access, you will to need to edit the IPtables rules as described in the Chapter 14 - Advanced.

4.6 Serial Port Cascading

Cascaded Ports enables you to cluster distributed Console Servers so that a large number of serial ports (up to 1000) can be configured and accessed through one IP address and managed through the one Management Console. One Console Server, the Master, controls other Console Servers as Slave units and all the serial ports on the Slave units appear as if they are part of the Master.

Each Slave connects to the Master with an SSH connection using public key authentication. So the Master accesses each Slave using an SSH key pair, rather than using passwords, ensuring secure authenticated communications. So the Slave Console Server units can be distributed locally on a LAN or remotely over public networks around the world.

4.6.1 Automatically generate and upload SSH keys To set up public key authentication, you must first generate an RSA or DSA key pair and upload them into the Master and Slave Console Servers. This can all be done automatically from the Master:

¾ Select SystemAdministration on Master’s Management Console

¾ Check Generate SSH keys automatically and click Apply

Tripp Lite B096-048 — 4.6 Serial Port Cascading diagram (page 47)
Fig. 47 · 4.6 Serial Port Cascading

¾ Click Apply

Page 48 of the Tripp Lite B096-048 user manual — 4.6 Serial Port Cascading
Page 48 · click to enlarge
Page 48

Now select whether to generate the keys using RSA and/or DSA (if unsure, select only RSA). Generating each set of keys will require approximately two minutes and the new keys will destroy any old keys of that type that may previously been uploaded. Also while the new generation is under way on the master, functions relying on SSH keys (e.g. cascading) may stop functioning until they are updated with the new set of keys. To generate keys:

¾ Select RSA Keys and/or DSA Keys

Tripp Lite B096-048 — 4.6 Serial Port Cascading diagram (page 48)
Fig. 48 · 4.6 Serial Port Cascading

¾ Once the new keys have been successfully generated simply Click here to return and the

keys will automatically be uploaded to the Master and connected Salves

4.6.2 Manually generate and upload SSH keys Alternately if you have a RSA or DSA key pair, you can manually upload them to the Master and Slave Console Servers.

create a key pair using ssh-keygen, PuTTYgen or a similar tool as detailed in Chapter 15.6

To manually upload the key public and private key pair to the Master Console Server:

¾ Select SystemAdministration on Master’s Management Console

¾ Browse to the location you have stored RSA (or DSA) Public Key and upload it to SSH RSA (DSA)

¾ Browse to the stored RSA (or DSA) Private Key and upload it to SSH RSA (DSA) Private Key

¾ Click Apply · Public Key · ¾ Click Apply

Page 49 of the Tripp Lite B096-048 user manual — 4.6 Serial Port Cascading
Page 49 · click to enlarge
Page 49
Tripp Lite B096-048 — 4.6 Serial Port Cascading diagram (page 49)
Fig. 49 · 4.6 Serial Port Cascading

Next, you must register the Public Key as an Authorized Key on the Slave. In the simple case with only one Master with multiple Slaves, you need only upload the one RSA or DSA public key for each Slave.

roles – Public Key and Authorized Key. For a more detailed explanation, refer to the Authorized Keys section of Chapter 15. Also refer to this chapter if you need to use more than one set of Authorized Keys in the Slave

¾ Select SystemAdministration on the Slave’s Management Console

¾ Browse again to the stored RSA (or DSA) Public Key and upload it to Slave’s SSH Authorized Key

The next step is to Fingerprint each new Slave-Master connection. This once-off step will validate that you are establishing an SSH session with the correct target. On the first connection the Slave will receive a fingerprint from the Master which will be used on all future connections:

¾ To establish the fingerprint, first log in the Master server as root and establish an SSH

connection to the Slave remote host:

Once the SSH connection has been established, you will be asked to accept the key. Answer yes and the fingerprint will be added to the list of known hosts. For more details on Fingerprinting, refer to Chapter 15.6

¾ If you are asked to supply a password, then there has been a problem with uploading keys. The

keys should remove any need to supply a password.

¾ Click Apply · # ssh remhost

Page 50 of the Tripp Lite B096-048 user manual — 4.6 Serial Port Cascading
Page 50 · click to enlarge
Page 50

4.6.3 Configure the Slaves and their serial ports You can now begin setting up the Slaves and configuring Slave serial ports from the Master Console Server:

Tripp Lite B096-048 — 4.6 Serial Port Cascading diagram (page 50)
Fig. 50 · 4.6 Serial Port Cascading
¾ Select Serial & NetworkCascaded Ports on the Master’s Management Console

¾ To add clustering support select Add Slave

SSH keys:

To define and configure a Slave:

¾ Enter the remote IP Address (or DNS Name) for the Slave Console Server

¾ Enter a brief Description and a short Label for the Slave (use a convention that enables effective

management of large networks of clustered Console Servers and the connected devices)

¾ Enter the full number of serial ports on the Slave unit in Number of Ports

¾ Click Apply. This will establish the SSH tunnel between the Master and the new Slave

The Serial & Network: Cascaded Ports menu displays all the Slaves and the port numbers that have been allocated on the Master. If the Master Console Server has 16 ports of its own, then ports 1-16 are pre-allocated to the Master. So the first Slave added will be assigned port number 17 and onwards.

Once you have added all the Slave Console Servers, the Slave serial ports and the connected devices are configurable and accessible from the Master’s Management Console menu, and accessible through the Master’s IP address.

¾ Select the appropriate Serial & Network: Serial Port and Edit to configure the serial ports on the

¾ Select the appropriate Serial & Network: Users & Groups to add new users with access

privileges to the Slave serial ports (or to extend existing users access privileges)

¾ Select the appropriate Serial & Network: Trusted Networks to specify network addresses that

can access nominated Slave serial ports

¾ Select the appropriate Alerts & Logging: Alerts to configure Slave port Connection, State Change

or Pattern Match alerts

¾ The configuration changes made on the Master are propagated out to all the Slaves when you

click Apply.

Slave

Page 51 of the Tripp Lite B096-048 user manual — 4.6 Serial Port Cascading
Page 51 · click to enlarge
Page 51

4.6.4 Managing the Slaves The Master is in control of the Slave serial ports. So, for example, if you change a User’s access privileges or edit any serial port setting on the Master, the updated configuration files will be sent out to each Slave in parallel. Each Slave will then automatically make changes to their local configurations (and only make those changes that relate to its particular serial ports).

You can still use the local Slave Management Console to change the settings on any Slave serial port (such as to alter the baud rates). However these changes will be overwritten next time the Master sends out a configuration file update.

Also while the Master is in control of all Slave serial port related functions, it is not master over the Slave network host connections or over the Slave Console Server system itself.

So Slave functions such as IP, SMTP & SNMP Settings, Date &Time, DHCP server must be managed by accessing each Slave directly and these functions are not overwritten when configuration changes are propagated from the Master. Similarly, the Slave’s Network Host and IPMI settings have to be configured at each Slave.

Also, the Master’s Management Console provides a consolidated view of the settings for its own and all the Slave’s serial ports. However, the Master does not provide a fully consolidated view. For example, if you want to find out who is logged in to cascaded serial ports from the Master, you’ll see that Status: Active Users only displays those users active on the Master’s ports, so you may need to write custom scripts to provide this view. This is covered in Chapter 11.

Page 52 of the Tripp Lite B096-048 user manual — 5.1 OoB Dial-In Access
Page 52 · click to enlarge
Page 52

5. FAILOVER AND OUT-OF-BAND ACCESS

Introduction

The Console Server has a number of failover and out-of-band access capabilities to ensure availability in the event there are difficulties in accessing the Console Server through the principal network path. This chapter covers:

ƒ Out-of-band (OoB) access from a remote location using dial-up modem

ƒ OoB access using an alternate broadband link (B096-048/016 models only)

5.1 OoB Dial-In Access

To enable OoB dial-in access, first set up the Console Server configuration for dial-in PPP access. Once the Console Server is so configured, it will wait for an incoming connection from a dial-in at a remote site.

Then remote Administrator’s must be configured to dial-in and must establish a network connection to the Console Server.

Tripp Lite B096-048 — 5.1 OoB Dial-In Access diagram (page 52)
Fig. 51 · 5.1 OoB Dial-In Access

016 Console Servers need an external modem to be attached via a serial cable to their DB9 port.

5.1.1 Configure dial-in PPP

To enable dial-in PPP access on the Console Server modem port/ internal modem:

ƒ Out-dial failover · ƒ Broadband failover

Page 53 of the Tripp Lite B096-048 user manual — 5. FAILOVER AND OUT-OF-BAND ACCESS
Page 53 · click to enlarge
Page 53
Tripp Lite B096-048 — 5. FAILOVER AND OUT-OF-BAND ACCESS diagram (page 53)
Fig. 52

¾ Select the System: Dial menu option and the port to be configured (Serial DB9 Port or Internal

data bits and 1 stop bit, with software (Xon-Xoff) flow control enabled. You can modify the baud rate and flow control using the Management Console. You can further configure the console/modem port settings by editing /etc/mgetty.config files as described in Chapter 14.

¾ Select the Baud Rate and Flow Control that will communicate with the modem

¾ Check the Enable Dial-In Access box

¾ Enter the User name and Password to be used for the dial-in PPP link

¾ In the Remote Address field, enter the IP address to be assigned to the dial-in client. You can

select any address for the Remote IP Address. However, it and the Local IP Address must both be in the same network range (e.g. 200.100.1.12 and 200.100.1.67)

¾ In the Local Address field, enter the IP address for the Dial-In PPP Server. This is the IP address

that will be used by the remote client to access Console Server once the modem connection is

Modem Port)

Page 54 of the Tripp Lite B096-048 user manual — 5. FAILOVER AND OUT-OF-BAND ACCESS
Page 54 · click to enlarge
Page 54

established. Again, you can select any address for the Local IP Address but both must be in the same network range as the Remote IP Address

¾ The Default Route option enables the dialed PPP connection to become the default route for

¾ The Custom Modem Initialization option allows a custom AT string modem initialization string

to be entered (e.g. AT&C1&D3&K3)

¾ Then select the Authentication Type to be applied to the dial-in connection. The Console Server

uses authentication to challenge Administrators who dial-in to the Console Server. (For dial-in access, the username and password received from the dial-in client are verified against the local authentication database stored on the Console Server). The Administrator must also have their client computer configured to use the selected authentication scheme. Select PAP CHAP MSCHAPv2 or None and click Apply

None With this selection, no username or password authentication is required for dial-in access. This is not recommended.

PAP Password Authentication Protocol (PAP) is the usual method of user authentication used on the internet: sending a username and password to a server where they are compared with a table of authorized users. Whilst most common, PAP is the least secure of the authentication options.

CHAP Challenge-Handshake Authentication Protocol (CHAP) is used to verify a user's name and password for PPP Internet connections. It is more secure than PAP, the other main authentication protocol.

MSCHAPv2 Microsoft Challenge Handshake Authentication Protocol (MSCHAP) is authentication for PPP connections between a computer using a Microsoft Windows operating system and a network access server. It is more secure than PAP or CHAP, and is the only option that also supports data encryption

¾ Console Servers all support dial-back for additional security. Check the Enable Dial-Back box and

enter the phone number to be called to re-establish an OoB link once a dial-in connection has been logged

5.1.2 Using SDT Connector client for dial-in

Administrators can use their SDT Connector client to set up secure OoB dial-in access to all their remote Console Servers. With a point and click you can initiate a dial-up connection. Refer to Chapter 6.5.

5.1.3 Set up Windows XP/ 2003/Vista client for dial-in

Tripp Lite B096-048 — 5. FAILOVER AND OUT-OF-BAND ACCESS diagram (page 54)
Fig. 53

¾ Open Network Connections in Control Panel and click the

the Console Server · New Connection Wizard

Page 55 of the Tripp Lite B096-048 user manual — 5. FAILOVER AND OUT-OF-BAND ACCESS
Page 55 · click to enlarge
Page 55
Tripp Lite B096-048 — 5. FAILOVER AND OUT-OF-BAND ACCESS diagram (page 55)
Fig. 54

¾ Select Connect to the Internet and click Next

¾ On the Getting Ready screen select Set Up My Connection Manually and click Next

¾ On the Internet Connection screen select Connect Using a Dial-Up Modem and click Next

¾ Enter a Connection Name (any name you choose) and the dial-up Phone Number that will

connect thru to the Console Server modem

Tripp Lite B096-048 — 5. FAILOVER AND OUT-OF-BAND ACCESS diagram (page 55)
Fig. 55

¾ Enter the PPP User Name and Password for have set up for the Console Server

5.1.4 Set up earlier Windows clients for dial-in

¾ For Windows 2000, the PPP client set up procedure is the same as above, except you get to the

Dial-Up Networking Folder by clicking the Start button and selecting Settings. Then click Network and Dial-up Connections and click Make New Connection

¾ Similarly, for Windows 98, you double-click My Computer on the Desktop, then open Dial-Up

Networking and double click Make New Connection and proceed as above

Page 56 of the Tripp Lite B096-048 user manual — 5.3 Broadband Ethernet Failover (B096-048/016 only)
Page 56 · click to enlarge
Page 56

5.1.5 Set up Linux clients for dial-in

The online tutorial http://www.yolinux.com/TUTORIALS/LinuxTutorialPPP.html presents a selection of methods for establishing a dial up PPP connection:

- Command line PPP and manual configuration (which works with any Linux distribution) - Using the Linuxconf configuration tool (for Red Hat compatible distributions). This configures the scripts ifup/ifdown to start and stop a PPP connection - Using the Gnome control panel configuration tool - - WVDIAL and the Redhat "Dialup configuration tool" - GUI dial program X-isp. Download/Installation/Configuration

Note For all PPP clients:

ƒ Set the PPP link up with TCP/IP as the only protocol enabled ƒ Specify that the Server will assign IP address and do DNS ƒ Do not set up the Console Server PPP link as the default for Internet connection

5.2 OoB Broadband Access (B096-048/016 only)

The B096-048/016 Console Server Management Switch has a second Ethernet network port that can be configured for alternate and OoB (out-of-band) broadband access. With two active broadband access paths to the Console Server, in the event you are unable to access through the primary management network, you may still have access through the alternate broadband path (e.g. a T1 link):

¾ On the SystemIP menu, select Management LAN Interface and configure the IP Address,

Subnet Mask, Gateway and DNS with the access settings that relate to the alternate link

¾ Ensure that when configuring the principal Network Interface connection, you set the Failover

5.3 Broadband Ethernet Failover (B096-048/016 only)

The second Ethernet port on the B096-048/016 Console Server Management Switch can also be configured for failover to ensure transparent high availability.

Interface to None

Page 57 of the Tripp Lite B096-048 user manual — Note For all PPP clients:
Page 57 · click to enlarge
Page 57
Tripp Lite B096-048 — Note For all PPP clients: diagram (page 57)
Fig. 56 · Note For all PPP clients:

¾ When configuring the principal network connection on the System: IP Network Interface menu, select Management LAN (eth1) as the Failover Interface to be used when a fault has been detected with main Network Interface (eth0)

¾ Specify the Probe Addresses of two sites (the Primary and Secondary) that the B096-048/016 is to ping to determine if Network (eth0) is still operational

Tripp Lite B096-048 — Note For all PPP clients: diagram (page 57)
Fig. 57 · Note For all PPP clients:
Page 58 of the Tripp Lite B096-048 user manual — 5.4 Dial-Out Failover
Page 58 · click to enlarge
Page 58

¾ Then configure Management LAN Interface (eth1) with the same IP setting that you used for the main Network Interface (eth0) to ensure transparent redundancy

Tripp Lite B096-048 — 5.4 Dial-Out Failover diagram (page 58)
Fig. 58 · 5.4 Dial-Out Failover

In this mode, Network 2 (eth1) is available as the transparent back-up port to Network 1 (eth0) for accessing the management network. Network 2 will automatically and transparently take over the work of Network 1 if for any reason Network 1 becomes unavailable. And when Network 1 becomes available again, it takes over the work again.

5.4 Dial-Out Failover

The Console Servers can be configured so a dial-out PPP connection is automatically set up in the event of a disruption in the principal management network:

¾ When configuring the principal network connection in System: IP, specify Internal Modem (or the Dial Serial DB9 if using an external modem on the Console port) as the Failover Interface to be used when a fault has been detected with Network1 (eth0)

¾ Specify the Probe Addresses of two sites (the Primary and Secondary) that the Console Server is to ping to determine if Network1 is still operational

¾ Select the System: Dial menu option and the port to be configured (Serial DB9 Port or Internal Modem Port)

¾ Select the Baud Rate and Flow Control that will communicate with the modem

/etc/mgetty.config files as described in Chapter 13.

¾ Check the Enable Dial-Out Access box and enter the access details for the remote PPP

server to be called

Page 59 of the Tripp Lite B096-048 user manual — 5.4 Dial-Out Failover
Page 59 · click to enlarge
Page 59
Tripp Lite B096-048 — 5.4 Dial-Out Failover diagram (page 59)
Fig. 59 · 5.4 Dial-Out Failover
Tripp Lite B096-048 — 5.4 Dial-Out Failover diagram (page 59)
Fig. 60 · 5.4 Dial-Out Failover
Page 60 of the Tripp Lite B096-048 user manual — Introduction
Page 60 · click to enlarge
Page 60

6. SECURE TUNNELING AND SDT CONNECTOR

Introduction

Each Console Server has an embedded SSH server and uses SSH tunneling. This enables one Console Server to securely manage all the systems and network devices in the data center, using text-based console tools (such as SSH, Telnet, SoL) or graphical desktop tools (VNC, RDP, HTTPS, HTTP, X11, VMware, DRAC, iLO etc).

To set up Secure Tunnel access, the computer being accessed can be located on the same local network as the Console Server, or attached to the Console Server via its serial COM port. The remote User/Administrator then connects to the Console Server through an SSH tunnel (via dial-up, wireless or ISDN modem); a broadband Internet connection; an enterprise VPN network or a local network.

Tripp Lite B096-048 — Introduction diagram (page 60)
Fig. 61 · Introduction

To set up the secure SSH tunnel from the Client computer to the Console Server, you must install and launch SSH client software on the User/Administrator’s computer. It is recommended that you use the SDT Connector client software supplied with the Console Server to do this. SDT Connector is simple to install and it auto-configures. It provides all your users with point-and-click access to all the systems and devices in the secure network. With one click, SDT Connector sets up a secure SSH tunnel from the client to the selected Console Server and then establishes a port forward connection to the target network connected host or serial connected device. It will then execute the client application that will be used in communicating with the host.

This chapter details the basic SDT Connector operations:

ƒ Configuring the Console Server for SSH tunneled access to network attached hosts and setting up permitted Services and Users access (Section 6.1)

ƒ Setting up the SDT Connector client with gateway, host, service and client application details and making connections between the Client computer and hosts connected to the Console Server (Section 6.2)

ƒ Using SDT Connector to browser access the Management Console (Section 6.3)

Page 61 of the Tripp Lite B096-048 user manual — 6.1 Configuring for SDT Tunneling to Hosts
Page 61 · click to enlarge
Page 61

ƒ Using SDT Connector to Telnet or SSH connect to devices that are serially attached to the Console Server (Section 6.4)

The chapter then covers more advanced SDT Connector and SDT tunneling topics:

ƒ Using SDT Connector for out of band access (Section 6.5)

ƒ Automatic importing and exporting of configurations (Section 6.6)

ƒ Configuring Public Key Authentication (Section 6.7)

ƒ Setting up a SDT Secure Tunnel for Remote Desktop (Section 6.8)

ƒ Setting up a SDT Secure Tunnel for VNC (Section 6.9)

ƒ Using SDT to IP connect to hosts that are serially attached to the Console Server (Section 6.10)

6.1 Configuring for SDT Tunneling to Hosts

To set up the Console Server to SDT access a network attached host, the host and the permitted services that are to be used in accessing that host need to be configured on the gateway, and User access privileges need to be specified:

¾ Add the new host and the permitted services using the Serial & Network: Network Hosts menu

as detailed in Network Hosts (Chapter 4.4). Only these permitted services will be forwarded by SDT to the host. All other services (TCP/UDP ports) will be blocked.

22 SSH (All SDT Tunneled connections) 23 Telnet on local LAN (forwarded inside tunnel) 80 HTTP on local LAN (forwarded inside tunnel) 3389 RDP on local LAN (forwarded inside tunnel) 5900 VNC on local LAN (forwarded inside tunnel) 73XX RDP over serial from local LAN – where XX is the serial port number (i.e. 7301to 7348) 79XX VNC over serial from local LAN – where XX is the serial port number

¾ Add the new Users using Serial & Network: Users & Groups menu as detailed in

Network Hosts (Chapter 4.4). Users can be authorized to access the Console Server ports and specified network-attached hosts. To simplify configuration, the Administrator can first set up Groups with group access permissions, then Users can be classified as members of particular Groups. 6.2 SDT Connector Configuration

The SDT Connector client works with all Console Servers. Each of these remote Console Servers has an embedded OpenSSH based server. This server can be configured to port forward connections from the SDT Connector client to hosts on their local network, as detailed in the previous chapter. The SDT Connector can also be pre-configured with the access tools and applications that will be available when access to a particular host has been established.

Page 62 of the Tripp Lite B096-048 user manual — 6.1 Configuring for SDT Tunneling to Hosts
Page 62 · click to enlarge
Page 62

SDT Connector can connect to the Console Server using an alternate OoB access. It can also be configured to access the Console Server itself and to access devices connected to serial ports on the Console Server.

6.2.1 SDT Connector client installation

¾ The SDT Connector set up program (SDTConnector Setup-1.n.exe or sdtcon-1.n.tar.gz) is

included on the CD supplied with your Console Server

¾ Run the set-up program:

Tripp Lite B096-048 — 6.1 Configuring for SDT Tunneling to Hosts diagram (page 62)
Fig. 62 · 6.1 Configuring for SDT Tunneling to Hosts

1.n.exe and the config file defaults.xml. If a config file already exists on the Windows computer, then it will not be overwritten. To remove an earlier config file, run the regedit command, search for “SDT Connector” and then remove the directory with this name.

For Linux and other Unix clients, SDTConnector.tar.gz application will install the sdtcon-1.n.jar and the config file defaults.xml

Once the installer completes, you will have a working SDT Connector client installed on your machine and an icon on your desktop:

¾ Click the SDT Connector icon on your desktop to start the client

Note SDT Connector is a Java application so it must have a Java Runtime Environment (JRE) installed. This can be freely downloaded from http://java.sun.com/j2se/. It will install on Windows 2000, XP, 2003, Vista computers and on most Linux platforms. Solaris platforms are also supported however they must have Firefox installed. SDT Connector can run on any system with Java 1.4.2 and above installed, but it assumes the web browser is Firefox, and that xterm -e Telnet opens a Telnet window

Page 63 of the Tripp Lite B096-048 user manual — 6.1 Configuring for SDT Tunneling to Hosts
Page 63 · click to enlarge
Page 63

To operate SDT Connector, add the new gateways to the client software by entering the access details for each Console Server (refer to Section 6.2.2). Then let the client auto-configure with all host and serial port connections from each Console Server (refer Section 6.2.3). Now point-and-click to connect to the Hosts and serial devices (refer to Section 6.2.4)

Alternately you can manually add network connected hosts (refer Section 6.2.5) as well as manually configure new services to be used when accessing the Console Server and the hosts (refer Section 6.2.6). Manually configure clients to run on the computer that will use the service to connect to the hosts and serial port devices (refer to Section 6.2.7 and 6.2.9). SDT Connector can also be set up to make an out-of- band connection to the Console Server (refer to Section 6.2.9)

6.2.2 Configuring a new gateway in the SDT Connector client

To create a secure SSH tunnel to a new Console Server:

¾ Click the New Gateway

icon or select the FileNew Gateway menu option
Tripp Lite B096-048 — 6.1 Configuring for SDT Tunneling to Hosts diagram (page 63)
Fig. 63 · 6.1 Configuring for SDT Tunneling to Hosts

¾ Enter the IP or DNS Address of the Console Server and the SSH port that will be used (typically

network, you will need to:

ƒ Determine the public IP address of the Console Server (or of the router/ firewall that connects the Console Server to the Internet) as assigned by the ISP. One way to find the public IP address is to access http://checkip.dyndns.org/ or http://www.whatismyip.com/ from a computer on the same network as the Console Server and note the reported IP address

ƒ Set port forwarding for TCP port 22 through any firewall/NAT/router that is located between SDT Connector and the Console Server so that it points to the Console Server. http://www.portforward.com has port forwarding instructions for a range of routers. Also you can use the Open Port Check tool from http://www.canyouseeme.org to check if port forwarding through local firewall/NAT/router devices has been properly configured

¾ Enter the Username and Password of a user on the gateway that has been enabled to connect

via SSH and/or create SSH port redirections

22)

Page 64 of the Tripp Lite B096-048 user manual — 6.1 Configuring for SDT Tunneling to Hosts
Page 64 · click to enlarge
Page 64
Tripp Lite B096-048 — 6.1 Configuring for SDT Tunneling to Hosts diagram (page 64)
Fig. 64 · 6.1 Configuring for SDT Tunneling to Hosts

¾ Optionally, you can enter a Descriptive Name to display instead of the IP or DNS address, and

any Notes or a Description of this gateway (such as its firmware version, site location or anything special about its network configuration).

¾ Click OK and an icon for the new gateway will now appear in the SDT Connector home page

Note For an SDT Connector user to access a Console Server (and then access specific hosts or serial devices connected to that Console Server), that user must first be set up on the Console Server, and must be authorized to access the specific ports / hosts (refer to Chapter 5). Only these permitted services will be forwarded through by SDT to the Host. All other services (TCP/UDP ports) will be blocked.

6.2.3 Auto-configure SDT Connector client with the user’s access privileges

Each user on the Console Server has an access profile. This has been configured with the specific connected hosts and serial port devices the user has authority to access, and a specific set of the enabled services for each of them. This configuration can be auto-uploaded into the SDT Connector client:

Tripp Lite B096-048 — 6.1 Configuring for SDT Tunneling to Hosts diagram (page 64)
Fig. 65 · 6.1 Configuring for SDT Tunneling to Hosts

¾ Click on the new gateway icon and select Retrieve Hosts. This will:

Page 65 of the Tripp Lite B096-048 user manual — 6.1 Configuring for SDT Tunneling to Hosts
Page 65 · click to enlarge
Page 65

ƒ configure access to network-connected Hosts that the user is authorized to access and set up (for each of these Hosts) the services (e.g. HTTPS, IPMI2.0) and the related IP ports being redirected

ƒ configure access to the Console Server itself (this is shown as a Local Services host)

ƒ configure access with the enabled services for the serial port devices connected to the Console Server

Tripp Lite B096-048 — 6.1 Configuring for SDT Tunneling to Hosts diagram (page 65)
Fig. 66 · 6.1 Configuring for SDT Tunneling to Hosts

6.2.4 Make an SDT connection through the gateway to a host

¾ Simply point at the host to be accessed and click on the service to be used in accessing that

host. The SSH tunnel to the gateway is then automatically established, the appropriate ports redirected through to the host, and the appropriate local client application is launched pointing at the local endpoint of the redirection:

Tripp Lite B096-048 — 6.1 Configuring for SDT Tunneling to Hosts diagram (page 65)
Fig. 67 · 6.1 Configuring for SDT Tunneling to Hosts
Page 66 of the Tripp Lite B096-048 user manual — 6.1 Configuring for SDT Tunneling to Hosts
Page 66 · click to enlarge
Page 66

Note The SDT Connector client can be configured with an unlimited number of Gateways. Each Gateway can be configured to port forward to an unlimited number of locally networked Hosts. Similarly there is no limit on the number of SDT Connector clients who can be configured to access the one Gateway. There are also no limits on the number of Host connections that an SDT Connector client can concurrently have open through the one Gateway tunnel.

However, there is a limit on the number of SDT Connector SSH tunnels that can be open at one time on a particular Gateway. The B096-016 / B096-048 Console Server Management Switch and B092-016 Console Server with PowerAlert each support at least 50 such concurrent connections. So for a site with a B096-016 gateway you can have, at any time, up to 50 users securely controlling an unlimited number of network attached computers, power devices and other appliances (routers, etc) at that site.

6.2.5 Manually adding hosts to the SDT Connector gateway

For each gateway, you can manually specify the network connected hosts that will be accessed through that Console Server; and for each host, specify the services that will used in communicating with the host

¾ Select the newly added gateway and click the Host icon

to create a host that will be accessible via this gateway. (Alternatively select File: New Host)

Tripp Lite B096-048 — 6.1 Configuring for SDT Tunneling to Hosts diagram (page 66)
Fig. 68 · 6.1 Configuring for SDT Tunneling to Hosts

¾ Enter the IP or DNS Host Address of the host (if this is a DNS address, it must be resolvable by

¾ Select which Services are to be used when accessing the new host. A range of service options

are pre-configured in the default SDT Connector client (RDP, VNC, HTTP, HTTPS, Dell RAC, VMWare etc). However if you wish to add new services to the range then proceed to the next section (Adding a new service) then return here

¾ Optionally, you can enter a Descriptive Name for the host to be displayed instead of the IP or

DNS address, as well as any Notes or a Description of this host (such as its operating system/release, or anything special about its configuration)

the gateway) · ¾ Click OK

Page 67 of the Tripp Lite B096-048 user manual — 6.1 Configuring for SDT Tunneling to Hosts
Page 67 · click to enlarge
Page 67

6.2.6 Manually adding new services to the new hosts

To extend the range of services that can be used when accessing hosts with SDT Connector:

¾ Select EditPreferences and click the Services tab. Click Add

¾ Enter a Service Name and click Add

¾ Under the General tab, enter the TCP Port that this service runs on (e.g. 80 for HTTP).

Optionally, select the client to be used to access the local endpoint of the redirection

Tripp Lite B096-048 — 6.1 Configuring for SDT Tunneling to Hosts diagram (page 67)
Fig. 69 · 6.1 Configuring for SDT Tunneling to Hosts

¾ Select which Client application is associated with the new service. A range of client application

options are pre-configured in the default SDT Connector (RDP client, VNC client, HTTP browser, HTTPS browser, Telnet client etc). However if you wish to add new client applications to this range, then proceed to the next section (Adding a new client) and then return here

Tripp Lite B096-048 — 6.1 Configuring for SDT Tunneling to Hosts diagram (page 67)
Fig. 70 · 6.1 Configuring for SDT Tunneling to Hosts

¾ Click OK, then Close

A service typically consists of a single SSH port redirection and a local client to access it. However it may consist of several redirections; some or all of which may have clients associated with them.

An example is the Dell RAC service. The first redirection is for the HTTPS connection to the RAC server: it has a client associated with it (web browser) that is launched immediately upon clicking the button for this service.

Page 68 of the Tripp Lite B096-048 user manual — 6.1 Configuring for SDT Tunneling to Hosts
Page 68 · click to enlarge
Page 68

The second redirection is for the VNC service that the user may choose to launch later from the RAC web console. It automatically loads in a Java client served through the web browser, so it does not need a local client associated with it.

Tripp Lite B096-048 — 6.1 Configuring for SDT Tunneling to Hosts diagram (page 68)
Fig. 71 · 6.1 Configuring for SDT Tunneling to Hosts

¾ On the Add Service screen, you can click Add as many times as needed to add multiple new port

redirections and associated clients

You may also specify Advanced port redirection options:

¾ Enter the local address to bind to when creating the local endpoint of the redirection. It is not

usually necessary to change this from "localhost".

¾ Enter a local TCP port to bind to when creating the local endpoint of the redirection. If this is left

blank, a random port will be selected.

Tripp Lite B096-048 — 6.1 Configuring for SDT Tunneling to Hosts diagram (page 68)
Fig. 72 · 6.1 Configuring for SDT Tunneling to Hosts

the TCP SSH redirection, so in effect it is a tunnel within a tunnel.

Enter the UDP port on which the service is running on the host. This will also be the local UDP port that SDT Connector binds as the local endpoint of the tunnel.

Page 69 of the Tripp Lite B096-048 user manual — 6.1 Configuring for SDT Tunneling to Hosts
Page 69 · click to enlarge
Page 69

6.2.7 Adding a client program to be started for the new service

Clients are local applications that may be launched when a related service is clicked. To add to the pool of client programs:

¾ Select EditPreferences and click the Client tab. Click Add
Tripp Lite B096-048 — 6.1 Configuring for SDT Tunneling to Hosts diagram (page 69)
Fig. 73 · 6.1 Configuring for SDT Tunneling to Hosts

¾ Enter a Name for the client. Enter the Path to the executable file for the client (or click Browse

to locate the executable)

¾ Enter a Command Line associated with launching the client application. SDT Connector typically

launches a client using command line arguments to point it to the local endpoint of the redirection. There are three special keywords for specifying the command line format. When launching the client, SDT Connector substitutes these keywords with the appropriate values:

%path% is path to the executable file, i.e. the previous field.

%host% is the local address to which the local endpoint of the redirection is bound, i.e. the Local Address field for the Service redirection Advanced options.

%port% is the local port to which the local endpoint of the redirection is bound, i.e. the Local TCP Port field for the Service redirection Advanced options. If this port is unspecified (i.e. "Any"), the appropriate randomly selected port will be substituted.

For example, SDT Connector is preconfigured for Windows installations with a HTTP service client that will connect with whichever local browser the local Windows user has configured as the default. Otherwise the default browser used is Firefox:

Page 70 of the Tripp Lite B096-048 user manual — 6.1 Configuring for SDT Tunneling to Hosts
Page 70 · click to enlarge
Page 70
Tripp Lite B096-048 — 6.1 Configuring for SDT Tunneling to Hosts diagram (page 70)
Fig. 74 · 6.1 Configuring for SDT Tunneling to Hosts

Also some clients are launched in a command line or terminal window. The Telnet client is an example of this:

Tripp Lite B096-048 — 6.1 Configuring for SDT Tunneling to Hosts diagram (page 70)
Fig. 75 · 6.1 Configuring for SDT Tunneling to Hosts

6.2.8 Dial-in configuration

If the client computer is dialing into Local/Console port on the Console Server, you will need to set up a dial-in PPP link:

¾ Configure the Console Server for dial-in access (following the steps in the Configuring for Dial-In

PPP Access section in Chapter 5, Configuring Dial In Access)

¾ Set up the PPP client software at the remote User computer (following the Set up the remote

Client section in Chapter 5)

Once you have a dial-in PPP connection established, you can then set up the secure SSH tunnel from the remote Client computer to the Console Server.

6.2.9 Choosing an alternate SSH client (e.g. PuTTY)

To set up the secure SSH tunnel from the Client computer to the Console Server, you must install and launch SSH client software on the Client computer. As described above it is recommended you use the

¾ Click OK

Page 71 of the Tripp Lite B096-048 user manual — 6.1 Configuring for SDT Tunneling to Hosts
Page 71 · click to enlarge
Page 71

SDT Connector client software that is supplied with the gateway. However there is also a wide selection of commercial and free SSH client programs that are supported:

- PuTTY is a complete (though not very user-friendly:) freeware implementation of SSH for Win32 and UNIX platforms

- SSHTerm is a useful open source SSH communications package

- SSH Tectia is a leading end-to-end commercial communications security solution for the enterprise

- Reflection for Secure IT (formerly F-Secure SSH) is another good commercial SSH-based security solution

By way of example, the steps below show the establishment of an SSH connection and then forwarding the RDP port over this SSH connection, using the PuTTY client software:

Tripp Lite B096-048 — 6.1 Configuring for SDT Tunneling to Hosts diagram (page 71)
Fig. 76 · 6.1 Configuring for SDT Tunneling to Hosts

¾ Under the Session tab, enter the IP address of the Console Server in the Host Name or IP

address field.

ƒ For dial-in connections, this IP address will be the Local Address that you assigned to the

Console Server when you set it up as the Dial-In PPP Server

ƒ For Internet (or local/VPN connections) connections this will be the public IP address of the

¾ Select the SSH Protocol, and the Port will be set as 22

¾ Under the SSH -> Tunnels tab, Add new forwarded port specifying the Source port as 1234 (or

any number you choose)

¾ Set the Destination:

ƒ If your destination computer is network-connected to the Console Server, set the Destination

as <SDT Host IP address/DNS Name>:3389. For example, if the SDT Host IP Address you

Console Server

Page 72 of the Tripp Lite B096-048 user manual — 6.1 Configuring for SDT Tunneling to Hosts
Page 72 · click to enlarge
Page 72

specified when setting up the SDT Hosts on the Console Server was accounts.myco.intranet.com, then specify the Destination as accounts.myco.intranet.com:3389

Tripp Lite B096-048 — 6.1 Configuring for SDT Tunneling to Hosts diagram (page 72)
Fig. 77 · 6.1 Configuring for SDT Tunneling to Hosts

ƒ If your destination computer is serially connected to the Console Server, set the Destination

as <port label>:3389. For example, if the Label you specified on the SDT enabled serial port on the Console Server is win2k3, then specify the remote host as win2k3:3389. Alternately, you can set the Destination as portXX:3389 where XX is the SDT enabled serial port number. So for example, if port 4 is on the Console Server is to carry the RDP traffic then specify port04:3389

Page 73 of the Tripp Lite B096-048 user manual — 6.1 Configuring for SDT Tunneling to Hosts
Page 73 · click to enlarge
Page 73
Tripp Lite B096-048 — 6.1 Configuring for SDT Tunneling to Hosts diagram (page 73)
Fig. 78 · 6.1 Configuring for SDT Tunneling to Hosts

¾ Select Local and click the Add button

¾ Click Open to SSH connect the Client computer to the Console Server. You will now be prompted

for the Username/Password for the Console Server User you SDT enabled

computers using SSH as above. This will protect against the risk of the “man in the middle” attacks to which RDP has a vulnerability http://www.securiteam.com/windowsntfocus/5EP010KG0G.html

To set up the secure SSH tunnel from the Client (Viewer) computer to the Console Server for VNC, follow the steps above. However, when configuring the VNC port redirection specify port 5900 (rather than port 3389 as was used for RDP) e.g. if using PuTTY:

Page 74 of the Tripp Lite B096-048 user manual — 6.1 Configuring for SDT Tunneling to Hosts
Page 74 · click to enlarge
Page 74
Tripp Lite B096-048 — 6.1 Configuring for SDT Tunneling to Hosts diagram (page 74)
Fig. 79 · 6.1 Configuring for SDT Tunneling to Hosts

very important. VNC uses a random challenge-response system to provide the basic authentication that allows you to connect to a VNC server. This is reasonably secure and the password is not sent over the network.

However, once connected, all subsequent VNC traffic is unencrypted. So a malicious user could snoop your VNC session. Also there are VNC scanning programs available, which will scan a subnet looking for computers which are listening on one of the ports which VNC uses.

Tunneling VNC over a SSH connection ensures all traffic is strongly encrypted. Also no VNC port is ever open to the internet, so anyone scanning for open VNC ports will not be able to find your computers. When tunneling VNC over a SSH connection, the only port which you're opening on your Console Server is the SDT port 22.

So sometimes it may be prudent to tunnel VNC through SSH even when the Viewer computer and the Console Server are both on the same local network.

To set up the secure SSH tunnel for an HTTP browser connection from the client computer, follow the steps above. However when configuring the port redirection, specify port 80 (rather than port 3389 as was used for RDP) e.g. if using PuTTY:

Tripp Lite B096-048 — 6.1 Configuring for SDT Tunneling to Hosts diagram (page 74)
Fig. 80 · 6.1 Configuring for SDT Tunneling to Hosts
Page 75 of the Tripp Lite B096-048 user manual — 6.3 SDT Connector to Management Console
Page 75 · click to enlarge
Page 75

6.3 SDT Connector to Management Console

SDT Connector can also be configured for browser access to the gateway’s Management Console – and for Telnet or SSH access to the gateway command line. For these connections to the gateway itself, you must configure SDT Connector to access the gateway (itself) by setting the Console Server up as a host, and then configuring the appropriate services:

¾ Launch SDT Connector on your computer. Assuming you have already set up the Console Server

as a Gateway in your SDT Connector client (with username/ password etc), select this newly added Gateway and click the Host icon to create a host. Alternatively, select File -> New Host

¾ Enter 127.0.0.1 as the Host Address and give some details in Descriptive Name/Notes. Click OK

Tripp Lite B096-048 — 6.3 SDT Connector to Management Console diagram (page 75)
Fig. 81 · 6.3 SDT Connector to Management Console

¾ Click the HTTP or HTTPS Services icon to access the gateway's Management Console, and/or

click SSH or Telnet to access the gateway command line console

allow port forwarded network access to itself:

¾ Browse to the Console Server and select Network Hosts from Serial & Network. Click Add

Host and in the IP Address/DNS Name field enter 127.0.0.1 (this is the Console Server's network loopback address). Then enter Loopback in Description

¾ Remove all entries under Permitted Services except for those that will be used in accessing

the Management Console (80/http or 443/https) or the command line (22/ssh or 23/Telnet). Scroll to the bottom and click Apply

¾ Administrators by default have gateway access privileges. However for Users to access the

gateway Management Console, you will need to give those Users the required access privileges. Select Users & Groups from Serial & Network. Click Add User. Enter a Username, Description and Password/Confirm. Select 127.0.0.1 from Accessible Host(s) and click Apply

Page 76 of the Tripp Lite B096-048 user manual — 6.4 SDT Connector - Telnet or SSH connect to serially attached devices
Page 76 · click to enlarge
Page 76

6.4 SDT Connector - Telnet or SSH connect to serially attached devices

SDT Connector can also be used to access text consoles on devices that are attached to the Console Server’s serial ports. For these connections, you must configure the SDT Connector client software with a Service that will access the target gateway serial port, and then set the gateway up as a host:

¾ Launch SDT Connector on your computer. Select Edit -> Preferences and click the Services tab.

¾ Enter "Serial Port 2" in Service Name and click Add

¾ Select Telnet client as the Client. Enter 2002 in TCP Port. Click OK, then Close and Close again

Tripp Lite B096-048 — 6.4 SDT Connector - Telnet or SSH connect to serially attached devices diagram (page 76)
Fig. 82 · 6.4 SDT Connector - Telnet or SSH connect to seriall…

¾ Assuming you have already set up the target Console Server as a gateway in your SDT Connector

client (with username/ password etc), select this gateway and click the Host icon to create a host. Alternatively, select File -> New Host.

¾ Enter 127.0.0.1 as the Host Address and select Serial Port 2 for Service. In Descriptive Name,

enter something along the lines of Loopback ports, or Local serial ports. Click OK.

¾ Click Serial Port 2 icon for Telnet access to the serial console on the device attached to serial

port #2 on the gateway

To enable SDT Connector to access to devices connected to the gateway’s serial ports, you must also configure the Console Server itself to allow port forwarded network access to itself, and enable access to the nominated serial port:

¾ Browse to the Console Server and select Serial Port from Serial & Network

¾ Click Edit to selected Port # (e.g. Port 2 if the target device is attached to the second serial port).

Ensure the port's serial configuration is appropriate for the attached device

¾ Scroll down to Console Server Setting and select Console Server Mode. Check Telnet (or SSH)

and scroll to the bottom and click Apply

¾ Select Network Hosts from Serial & Network and click Add Host

¾ In the IP Address/DNS Name field, enter 127.0.0.1 (this is the Console Server's network

loopback address) and enter Loopback in Description

¾ Remove all entries under Permitted Services and select TCP and enter 200n in Port. (This

configures the Telnet port enabled in the previous step, so for Port 2 you would enter 2002)

Click Add

Page 77 of the Tripp Lite B096-048 user manual — 6.5 Using SDT Connector for out-of-band connection to the gateway
Page 77 · click to enlarge
Page 77

¾ Click Add then scroll to the bottom and click Apply

¾ Administrators by default have gateway and serial port access privileges; however for Users to

access the gateway and the serial port, you will need to give those Users the required access privileges. Select Users & Groups from Serial & Network. Click Add User. Enter a Username, Description and Password/Confirm. Select 127.0.0.1 from Accessible Host(s) and select Port 2 from Accessible Port(s). Click Apply.

6.5 Using SDT Connector for out-of-band connection to the gateway

SDT Connector can also be set up to connect to the Console Server (gateway) via out-of-band (OoB). OoB access uses an alternate path for connecting to the gateway (i.e. not the one used for regular data traffic). OoB access is useful when the primary link into the gateway is unavailable or unreliable.

Typically a gateway's primary link is a broadband Internet connection or Internet connection via a LAN or VPN, and the secondary out-of-band connectivity is provided by a dial-up or wireless modem directly attached to the gateway. So out-of-band access enables you to access the hosts and serial devices on the network, diagnose any connectivity issues, and restore the gateway's primary link.

In SDT Connector, OoB access is configured by providing the secondary IP address of the gateway, and telling SDT Connector how to start and stop the OoB connection. Starting an OoB connection may be achieved by initiating a dial-up connection, or adding an alternate route to the gateway. SDT Connector allows for maximum flexibility by allowing you to provide your own scripts or commands for starting and stopping the OoB connection.

Tripp Lite B096-048 — 6.5 Using SDT Connector for out-of-band connection to the gateway diagram (page 77)
Fig. 83 · 6.5 Using SDT Connector for out-of-band connection t…

To configure SDT Connector for OoB access:

¾ When adding a new gateway or editing an existing gateway, select the Out Of Band tab

¾ Enter the secondary OoB IP address for the gateway (e.g. the IP address to be used when dialing

in directly). You may also modify the gateway's SSH port if it's not using the default of 22

¾ Enter the command or path to a script to start the OoB connection in Start Command

ƒ To initiate a pre-configured dial-up connection under Windows, use the following Start Command:

Page 78 of the Tripp Lite B096-048 user manual — 6.5 Using SDT Connector for out-of-band connection to the gateway
Page 78 · click to enlarge
Page 78

cmd /c start "Starting Out of Band Connection" /wait /min rasdial network_connection login password

The network_connection in the above is the name of the network connection as displayed in Control Panel -> Network Connections. Login is the dial-in username, and password is the dial-in password for the connection.

ƒ To initiate a pre-configured dial-up connection under Linux, use the following Start Command:

The network_connection in the above is the name of the connection.

¾ Enter the command or path to a script to stop the OoB connection in Stop Command

ƒ To stop a pre-configured dial-up connection under Windows, use the following Stop Command:

cmd /c start "Stopping Out of Band Connection" /wait /min rasdial network_connection /disconnect

The network_connection in the above is the name of the network connection as displayed in Control Panel -> Network Connections.

ƒ To stop a pre-configured dial-up connection under Linux, use the following Stop Command:

To make the OoB connection using SDT Connector:

¾ Select the gateway and click Out Of Band. The status bar will change color to indicate this

gateway is now being access using the OoB link rather than the primary link

Tripp Lite B096-048 — 6.5 Using SDT Connector for out-of-band connection to the gateway diagram (page 78)
Fig. 84 · 6.5 Using SDT Connector for out-of-band connection t…

When you connect to a service on a host behind the gateway, or to the Console Server gateway itself, SDT Connector will initiate the OoB connection using the provided Start Command. The OoB connection isn't stopped (using the provided Stop Command) until Out Of Band under Gateway Actions is clicked off, at which point the status bar will return to its normal color.

pon network_connection · poff network_connection

Page 79 of the Tripp Lite B096-048 user manual — 6.7 SDT Connector Public Key Authentication
Page 79 · click to enlarge
Page 79

6.6 Importing (and exporting) preferences

To enable the distribution of pre-configured client config files, SDT Connector has an Export/Import facility:

Tripp Lite B096-048 — 6.6 Importing (and exporting) preferences diagram (page 79)
Fig. 85 · 6.6 Importing (and exporting) preferences

¾ To save a configuration .xml file (for backup or for importing into other SDT Connector clients),

select File -> Export Preferences and select the location to save the configuration file

¾ To import a configuration, select File -> Import Preferences and select the .xml configuration file to

6.7 SDT Connector Public Key Authentication

SDT Connector can authenticate against an SSH gateway using your SSH key pair rather than requiring your to enter your password. This is known as public key authentication.

To use public key authentication with SDT Connector, you must first add the public part of your SSH key pair to your SSH gateway:

¾ Ensure the SSH gateway allows public key authentication. This is typically the default behavior

¾ If you do not already have a public/private key pair for your client computer (the one which the

SDT Connector is running) generate them now using ssh-keygen, PuTTYgen or a similar tool. You may use RSA or DSA, however it is important that you leave the passphrase field blank:

- PuTTYgenhttp://www.chiark.greenend.org.uk/~sgtatham/putty/download.html
- OpenSSHhttp://www.openssh.org/
- OpenSSH (Windows)http://sshwindows.sourceforge.net/download/

¾ Upload the public part of your SSH key pair (this file is typically named id_rsa.pub or id_dsa.pub)

to the SSH gateway, or add it to the .ssh/authorized keys in your home directory on the SSH gateway

¾ Next, add the private part of your SSH key pair (this file is typically named id_rsa or id_dsa) to

SDT Connector. Click Edit -> Preferences -> Private Keys -> Add, locate the private key file and click OK

You do not have to add the public part of your SSH key pair; it is calculated using the private key.

SDT Connector will now use public key authentication when connecting through the SSH gateway (Console Server). You may have to restart SDT Connector to shut down any existing tunnels that were established using password authentication.

If you have a host behind the Console Server that you connect to by clicking the SSH button in SDT Connector, you may also wish to configure access to it for public key authentication as well. This configuration is entirely independent of SDT Connector and the SSH gateway. You must configure the

be installed

Page 80 of the Tripp Lite B096-048 user manual — 6.8 Setting up SDT for Remote Desktop Access
Page 80 · click to enlarge
Page 80

SSH client that SDT Connector launches (e.g. Putty, OpenSSH) and the host's SSH server for public key authentication. Essentially, what you are using is SSH over SSH, and the two SSH connections are entirely separate.

6.8 Setting up SDT for Remote Desktop Access

Microsoft’s Remote Desktop Protocol (RDP) enables the system manager securely to access and manage remote Windows computers: to reconfigure applications and user profiles, upgrade the server’s operating system, reboot the machine, etc. Secure Tunneling uses SSH tunneling, so this RDP traffic is securely transferred through an authenticated and encrypted tunnel.

SDT with RDP also allows remote Users to connect to Windows XP, Vista, Windows 2003 computers and to Windows 2000 Terminal Servers, and to have access to all of the applications, files, and network resources (with full graphical interface just as though they were in front of the computer screen itself). To set up a secure Remote Desktop connection, you must enable Remote Desktop on the target Windows computer that is to be accessed and configure the RPD client software on the client computer.

6.8.1 Enable Remote Desktop on the target Windows computer to be accessed

To enable Remote Desktop on the Windows computer being accessed:

¾ Open System in the Control Panel and click the Remote tab

Tripp Lite B096-048 — 6.8 Setting up SDT for Remote Desktop Access diagram (page 80)
Fig. 86 · 6.8 Setting up SDT for Remote Desktop Access

¾ Check Allow users to connect remotely to this computer

¾ Click Select Remote Users

Page 81 of the Tripp Lite B096-048 user manual — 6.8 Setting up SDT for Remote Desktop Access
Page 81 · click to enlarge
Page 81
Tripp Lite B096-048 — 6.8 Setting up SDT for Remote Desktop Access diagram (page 81)
Fig. 87 · 6.8 Setting up SDT for Remote Desktop Access

¾ To set the user(s) who can remotely access the system with RDP, click Add on the Remote

Desktop Users dialog box

Panel and proceed through the steps to nominate the new user’s name, password and account type (Administrator or Limited)

connects directly to the Windows root console. With Windows Server 2008 you can have multiple sessions, and with Server 2003 you have three sessions (the console session and two other general sessions). Therefore, more than one user can have an active session on a single computer.

When the remote user connects to the accessed computer on the console session, Remote Desktop automatically locks that computer (so no other user can access the applications and files). When you come back to the computer, you can unlock it by typing CTRL+ALT+DEL.

6.8.2 Configure the Remote Desktop Connection client

Now that you have the Client computer securely connected to the Console Server (either locally, or remotely, thru the enterprise VPN, or a secure SSH internet tunnel or a dial-in SSH tunnel), you are ready to establish the Remote Desktop connection from the Client. To do this you simply enable the Remote Desktop Connection on the remote client computer then point it to the SDT Secure Tunnel port in the Console Server:

A. On a Windows client computer

¾ Click Start. Point to Programs, then to Accessories, then Communications, and click Remote

Desktop Connection

Page 82 of the Tripp Lite B096-048 user manual — 6.8 Setting up SDT for Remote Desktop Access
Page 82 · click to enlarge
Page 82
Tripp Lite B096-048 — 6.8 Setting up SDT for Remote Desktop Access diagram (page 82)
Fig. 88 · 6.8 Setting up SDT for Remote Desktop Access

¾ In Computer, enter the appropriate IP Address and Port Number:

ƒ Where there is a direct local or enterprise VPN connection, enter the IP Address of the Console Server, and the Port Number of the SDT Secure Tunnel for the Console Server’s serial port (the one that is attached to the Windows computer to be controlled). For example, if the Windows computer is connected to serial Port 3 on a Console Server located at 192.168.0.50 then you would enter 192.168.0.50:7303.

ƒ Where there is an SSH tunnel (over a dial-up PPP connection or over a public internet connection or private network connection), simply enter the localhost as the IP address, i.e. 127.0.0.1. For Port Number, enter the source port you created when setting SSH tunneling/port forwarding (in Section 6.1.6) e.g. :1234.

¾ Click Option. In the Display section, specify an appropriate color depth (e.g. for a modem

connection it is recommended you not use over 256 colors). In Local Resources, specify the peripherals on the remote Windows computer that are to be controlled (printer, serial port, etc.)

Tripp Lite B096-048 — 6.8 Setting up SDT for Remote Desktop Access diagram (page 82)
Fig. 89 · 6.8 Setting up SDT for Remote Desktop Access

¾ Click Connect

Page 83 of the Tripp Lite B096-048 user manual — 6.8 Setting up SDT for Remote Desktop Access
Page 83 · click to enlarge
Page 83

Windows computers, you will need to download the RDP client:

ƒ Go to the Microsoft Download Center site http://www.microsoft.com/downloads/details.aspx?familyid=80111F21-D48D-426E-96C2- 08AA2BD23A49&displaylang=en and click the Download button

This software package will install the client portion of Remote Desktop on Windows 95, Windows 98 and 98 Second Edition, Windows Me, Windows NT 4.0, Windows 2000, and Windows 2003. When run, this software allows these older Windows platforms to remotely connect to a computer running Windows XP Professional or Windows 2003 Server

B. On a Linux or UNIX client computer:

¾ Launch the open source rdesktop client:

rdesktop -u windows-user-id -p windows-password -g 1200x950 ms-windows-terminal- server-host-name

Tripp Lite B096-048 — 6.8 Setting up SDT for Remote Desktop Access diagram (page 83)
Fig. 90 · 6.8 Setting up SDT for Remote Desktop Access

-r Device redirection. i.e. Redirect sound on remote machine to local device i.e. -0 -r sound (MS/Windows 2003)

-g Geometry: widthxheight or 70% screen percentage.

¾ You can use GUI front end tools like the GNOME Terminal Services Client tsclient to configure

and launch the rdesktop client. (Using tsclient also enables you to store multiple configurations of rdesktop for connection to many servers.)

Page 84 of the Tripp Lite B096-048 user manual — 6.8 Setting up SDT for Remote Desktop Access
Page 84 · click to enlarge
Page 84
Tripp Lite B096-048 — 6.8 Setting up SDT for Remote Desktop Access diagram (page 84)
Fig. 91 · 6.8 Setting up SDT for Remote Desktop Access

ƒ rpm -ivh rdesktop-1.2.0-1.i386.rpm

For Red Hat 8.0 or other distributions of Linux; download source, untar, configure, make, make then install.

rdesktop currently runs on most UNIX based platforms with the X Window System and can be downloaded from http://www.rdesktop.org/

C. On a Macintosh client:

¾ Download Microsoft's free Remote Desktop Connection client for Mac OS X

http://www.microsoft.com/mac/otherproducts/otherproducts.aspx?pid=remotedesktopclient

Page 85 of the Tripp Lite B096-048 user manual — 6.9 SDT SHH Tunnel for VNC
Page 85 · click to enlarge
Page 85

6.9 SDT SHH Tunnel for VNC

Alternately, with SDT and Virtual Network Computing (VNC), Users and Administrators can securely access and control Windows 98/NT/2000/XP/2003, Linux, Macintosh, Solaris and UNIX computers. There’s a range of popular VNC software available (UltraVNC, RealVNC, TightVNC) freely and commercially. To set up a secure VNC connection, install and configure the VNC Server software on the computer to be accessed. Then install and configure the VNC Viewer software on the Viewer computer.

6.9.1 Install and configure the VNC Server on the computer to be accessed

Virtual Network Computing (VNC) software enables users to remotely access computers running Linux, Macintosh, Solaris, UNIX, all versions of Windows and most other operating systems.

A. For Microsoft Windows servers (and clients):

Windows does not include VNC software, so you will need to download, install and activate a third party VNC Server software package:

RealVNC http://www.realvnc.com is fully cross-platform, so a desktop running on a Linux machine may be displayed on a Windows computer, on a Solaris machine, or on any number of other architectures. There is a Windows server, allowing you to view the desktop of a remote Windows machine on any of these platforms using exactly the same viewer. RealVNC was founded by members of the AT&T team who originally developed VNC.

Tripp Lite B096-048 — 6.9 SDT SHH Tunnel for VNC diagram (page 85)
Fig. 92 · 6.9 SDT SHH Tunnel for VNC

TightVNC http://www.tightvnc.com is an enhanced version of VNC. It has added features such as file transfer, performance improvements and read- only password support. They have just recently included a video drive much like UltraVNC. TightVNC is still free, cross-platform (Windows Unix and Linux) and compatible with the standard (Real) VNC.

UltraVNC http://ultravnc.com is easy to use, fast and free VNC software that has pioneered and perfected features that the other flavors have consistently refused or been very slow to implement for cross platform and minimalist reasons. UltraVNC runs under Windows operating systems (95, 98, Me, NT4, 2000, XP, 2003) Download UltraVNC from Sourceforge's UltraVNC file list

B. For Linux servers (and clients):

Most Linux distributions now include VNC Servers and Viewers. They are generally launched from the (Gnome/KDE etc) front end. For example, there’s VNC Server software with Red Hat Enterprise Linux 4 and a choice of Viewer client software. To launch:

¾ Select the Remote Desktop entry in the Main Menu -> Preferences menu

¾ Click the Allow other users checkbox to allow remote users to view and control your desktop

Page 86 of the Tripp Lite B096-048 user manual — 6.9 SDT SHH Tunnel for VNC
Page 86 · click to enlarge
Page 86
Tripp Lite B096-048 — 6.9 SDT SHH Tunnel for VNC diagram (page 86)
Fig. 93 · 6.9 SDT SHH Tunnel for VNC

¾ To set up a persistent VNC server on Red Hat Enterprise Linux 4:

o Set a password using vncpasswd o Edit /etc/sysconfig/vncservers o Enable the service with chkconfig vncserver on o Start the service with service vncserver start o Edit /home/username/.vnc/xstartup if you want a more advanced session than just twm

and an xterm C. For Macintosh servers (and clients):

OSXvnc http://www.redstonesoftware.com/vnc.html is a robust, full-featured VNC server for Mac OS X that allows any VNC client to remotely view and/or control Mac OS X machine. OSXvnc is supported by Redstone Software

D. Most other operating systems (Solaris, HPUX, PalmOS etc) either come with VNC bundled, or have

third-party VNC software that you can download

6.9.2 Install, configure and connect the VNC Viewer

VNC is truly platform-independent, so a VNC Viewer on any operating system can connect to a VNC Server on any other operating system. There are Viewers (and Servers) from a wide selection of sources (e.g. UltraVNC TightVNC or RealVNC) for most operating systems. There are also a wealth of Java viewers available so that any desktop can be viewed with any Java-capable browser (http://en.wikipedia.org/wiki/VNC lists many of the VNC Viewers sources).

¾ Install the VNC Viewer software and set it up for the appropriate speed connection

ƒ Set encoding to ZRLE (if you have a fast enough CPU) ƒ Decrease color level (e.g. 64 bit) ƒ Disable the background transmission on the Server or use a plain wallpaper (Refer to http://doc.uvnc.com for detailed configuration instructions)

¾ To establish the VNC connection, first configure the VNC Viewer, entering the VNC Server IP

address

Page 87 of the Tripp Lite B096-048 user manual — 6.9 SDT SHH Tunnel for VNC
Page 87 · click to enlarge
Page 87

A. When the Viewer computer is connected to the Console Server through an SSH tunnel (over the

public Internet, or a dial-in connection, or private network connection), enter localhost (or 127.0.0.1) as the IP VNC Server IP address and the source port you entered when setting SSH tunneling/port forwarding (in Section 6.2.6) e.g. :1234

Tripp Lite B096-048 — 6.9 SDT SHH Tunnel for VNC diagram (page 87)
Fig. 94 · 6.9 SDT SHH Tunnel for VNC

B. When the Viewer computer is connected directly to the Console Server (either locally or remotely

through a VPN or dial-in connection) and the VNC Host computer is serially connected to the Console Server, then enter the IP address of the Console Server unit with the TCP port that the SDT tunnel will use. The TCP port will be 7900 plus the physical serial port number (i.e. 7901 to 7948, so all traffic directed to port 79xx on the Console Server is tunneled through to port 5900 on the PPP connection on serial Port xx). For example, for a Windows Viewer computer using UltraVNC connecting to a VNC Server which is attached to Port 1 on a Console Server, enter 192.168.0.1

Tripp Lite B096-048 — 6.9 SDT SHH Tunnel for VNC diagram (page 87)
Fig. 95 · 6.9 SDT SHH Tunnel for VNC

¾ You can then establish the VNC connection by simply activating the VNC Viewer software on the

Viewer computer and entering the password

Page 88 of the Tripp Lite B096-048 user manual — 6.9 SDT SHH Tunnel for VNC
Page 88 · click to enlarge
Page 88
Tripp Lite B096-048 — 6.9 SDT SHH Tunnel for VNC diagram (page 88)
Fig. 96 · 6.9 SDT SHH Tunnel for VNC

following:

ƒ The Microsoft Remote Desktop How-To

http://www.microsoft.com/windowsxp/using/mobility/getstarted/remoteintro.mspx ƒ The Illustrated Network Remote Desktop help page

http://theillustratednetwork.mvps.org/RemoteDesktop/RemoteDesktopSetupandTroubleshooting.ht ml ƒ What is Remote Desktop in Windows XP and Windows Server 2003? by Daniel Petri

http://www.petri.co.il/what's_remote_desktop.htm ƒ Frequently Asked Questions about Remote Desktop

http://www.microsoft.com/windowsxp/using/mobility/rdfaq.mspx ƒ Secure remote access of a home network using SSH, Remote Desktop and VNC for the home user

http://theillustratednetwork.mvps.org/RemoteDesktop/SSH-RDP- VNC/RemoteDesktopVNCandSSH.html ƒ Taking your desktop virtual with VNC, Red Hat magazine

http://www.redhat.com/magazine/006apr05/features/vnc/ and http://www.redhat.com/magazine/007may05/features/vnc/ ƒ Wikipedia general background on VNC http://en.wikipedia.org/wiki/VNC

6.10 Using SDT to IP connect to hosts that are serially attached to the gateway

Network (IP) protocols like RDP, VNC and HTTP can also be used to connect to host devices that are serially connected through their COM port to the Console Server. To do this you must:

  • establish a PPP connection (Section 6.7.1) between the host and the gateway, then
  • set up Secure Tunneling - Ports on the Console Server (Section 6.7.2), then
  • configure SDT Connector to use the appropriate network protocol to access IP consoles on the host devices that are attached to the Console Server serial ports (Section 6.7.3)

6.10.1 Establish a PPP connection between the host COM port and Console Server

(This step is only necessary for serially connected computers)

Firstly, physically connect the COM port on the host computer that is to be accessed to the serial port on the Console Server. Then:

A. For non-Wndows computers (Linux, UNIX, Solaris etc), establish a PPP connection over the serial

port. The online tutorial http://www.yolinux.com/TUTORIALS/LinuxTutorialPPP.html presents a selection of methods for establishing a PPP connection for Linux

B. For Windows XP and 2003 computers, follow the steps below to set up an advanced network

connection between the Windows computer, through its COM port, to the Console Server. Both

Page 89 of the Tripp Lite B096-048 user manual — 6.9 SDT SHH Tunnel for VNC
Page 89 · click to enlarge
Page 89

Windows 2003 and Windows XP Professional allow you to create a simple dial-in service which can be used for the Remote Desktop/VNC/HTTP/X connection to the Console Server:

¾ Open Network Connections in Control Panel and click the New Connection Wizard

Tripp Lite B096-048 — 6.9 SDT SHH Tunnel for VNC diagram (page 89)
Fig. 97 · 6.9 SDT SHH Tunnel for VNC

¾ Select Set up an advanced connection and click Next

¾ On the Advanced Connection Options screen, select Accept Incoming Connections and click

¾ Select the Connection Device (i.e. the serial COM port on the Windows computer that you

cabled through to the Console Server). By default, select COM1. The COM port on the Windows computer should be configured to its maximum baud rate. Click Next

¾ On the Incoming VPN Connection Options screen, select Do not allow virtual private

connections and click Next

Tripp Lite B096-048 — 6.9 SDT SHH Tunnel for VNC diagram (page 89)
Fig. 98 · 6.9 SDT SHH Tunnel for VNC

Next

Page 90 of the Tripp Lite B096-048 user manual — 6.9 SDT SHH Tunnel for VNC
Page 90 · click to enlarge
Page 90

¾ Specify which Users will be allowed to use this connection. This should be the same Users who

were given Remote Desktop access privileges in the earlier step. Click Next

¾ On the Network Connection screen, select TCP/IP and click Properties

Tripp Lite B096-048 — 6.9 SDT SHH Tunnel for VNC diagram (page 90)
Fig. 99 · 6.9 SDT SHH Tunnel for VNC

¾ Select Specify TCP/IP addresses on the Incoming TCP/IP Properties screen. Nominate a From:

and a ToTCP/IP address and click Next

anywhere else on your network. The From: address will be assigned to the Windows XP/2003 computer and the To: address will be used by the Console Server. For simplicity, use the IP address as shown in the illustration above:

From169.134.13.1
To169.134.13.2

Alternately you can set the advanced connection and access on the Windows computer to use the Console Server defaults:

ƒ Specify 10.233.111.254 as the From: address

ƒ Select Allow calling computer to specify its own address

Also you could use the Console Server default username and password when you set up the new Remote Desktop User and give this User permission to use the advance connection to access the Windows computer:

ƒ The Console Server default Username is portXX where XX is the serial port number on the Console Server.

ƒ The default Password is portXX

So to use the defaults for an RDP connection to the serial port 2 on the Console Server, you would have set up a Windows user named port02

¾ When the PPP connection has been set up, a network icon will appear in the Windows task bar

Page 91 of the Tripp Lite B096-048 user manual — 6.9 SDT SHH Tunnel for VNC
Page 91 · click to enlarge
Page 91
Tripp Lite B096-048 — 6.9 SDT SHH Tunnel for VNC diagram (page 91)
Fig. 100 · 6.9 SDT SHH Tunnel for VNC

Put a check in the box for Always allow directly connected devices such as palmtop…..

Also, the option to Set up an advanced connection is not available in Windows 2003 if RRAS is configured. If RRAS has been configured, it is a simple task to enable the null modem connection for the dial-in configuration.

C. For earlier version Windows computers, follow the steps in Section B, above. To get to the Make

New Connection button:

ƒ For Windows 2000, click Start and select Settings. At the Dial-Up Networking Folder, click Network and Dial-up Connections and click Make New Connection. Note: you first may need to set up a connection over the COM port using Connect directly to another computer before proceeding to Set up an advanced connection

ƒ For Windows 98, you double-click My Computer on the Desktop, then open Dial-Up Networking and double-click

6.10.2 Set up SDT Serial Ports on Console Server

To set up RDP (and VNC) forwarding on the Console Server’s Serial Port that is connected to the Windows computer COM port:

¾ Select the Serial & Network: Serial Port menu option and click Edit (for the particular Serial Port

that is connected to the Windows computer COM port)

Page 92 of the Tripp Lite B096-048 user manual — 6.9 SDT SHH Tunnel for VNC
Page 92 · click to enlarge
Page 92

¾ On the SDT Settings menu, select SDT Mode (which will enable port forwarding and SSH

tunneling) and enter a Username and User Password.

Tripp Lite B096-048 — 6.9 SDT SHH Tunnel for VNC diagram (page 92)
Fig. 101 · 6.9 SDT SHH Tunnel for VNC

where XX is the serial port number. So the default username and password for Secure RDP over Port 2 is port02

¾ Ensure the Console Server Common Settings (Baud Rate, Flow Control) are the same as were set

up on the Windows computer COM port and click Apply

¾ RDP and VNC forwarding over serial ports is enabled on a Port basis. You can add Users who can

have access to these ports (or reconfigure User profiles) by selecting Serial & Network :User & Groups menu tag - as described earlier in Chapter 4 Configuring Serial Ports

6.10.3 Set up SDT Connector to SSH port forward over the Console Server Serial Port

In the SDT Connector software running on your remote computer, specify the gateway IP address of your Console Server and a username/password for a user you have setup on the Console Server that has access to the desired port.

Next, add a New SDT Host. In the Host address you need to put portxx where xx = the port to which you are connecting. Example, for port 3 you would have a Host Address of: port03 and then select the RDP Service check box.

Page 93 of the Tripp Lite B096-048 user manual — 7.1 Configure SMTP/SMS/SNMP/Nagios alert service
Page 93 · click to enlarge
Page 93

7. ALERTS AND LOGGING

Introduction

This chapter describes the alert generation and logging features of the Console Server. The alert facility monitors the serial ports, all logins, the power status and environmental monitors and probes. It sends emails, SMS, Nagios or SNMP alerts when specified trigger events occurs.

ƒ First, enable and configure the service that will be used to carry the alert (Section 7.1)

ƒ Then specify the alert trigger condition and the actual destination to which that particular alert is to be sent (Section 7.2)

The Console Servers can also be configured selectively to maintain log records of all access and communications with the Console Server and with the attached serial devices, all system activity and a history of the status of any attached environmental monitors, UPS and PDU devices. The Console Servers can also log access and communications with network attached hosts.

ƒ If port logs are to be maintained on a remote server, then the access path to this location needs to be configured (Section 7.3)

ƒ Then you need to activate and set the desired levels of logging for each serial (Section 7.4) and/or network port (Section 7.5) and/or power and environment devices (refer to Chapter 8)

7.1 Configure SMTP/SMS/SNMP/Nagios alert service

The Alerts facility monitors nominated serial ports/hosts/UPSs/PDUs/EMDs, etc. for trigger conditions and, when triggered, sends an alert notification over the nominated alert service. Before setting up the alert trigger, you must configure these alert services:

7.1.1 Email alerts

The Console Server uses SMTP (Simple Mail Transfer Protocol) for sending the email alert notifications. To use SMTP, the Administrator must configure a valid SMTP server for sending the email:

¾ Select Alerts & LoggingSMTP &SMS
Page 94 of the Tripp Lite B096-048 user manual — 7. ALERTS AND LOGGING
Page 94 · click to enlarge
Page 94
Tripp Lite B096-048 — 7. ALERTS AND LOGGING diagram (page 94)
Fig. 102

¾ In the SMTP Server field, enter the IP address of the outgoing mail Server

¾ You may enter a Sender email address which will appear as the “from” address in all email

notifications sent from this Console Server. Many SMTP servers check the sender’s email address with the host domain name to verify the address as authentic. So it may be useful to assign an email address for the Console Server such as consoleserver2@mydomian.com

¾ You may also enter a Username and Password if the SMTP server requires authentication

¾ Similarly you can specify the Subject Line that will be sent with the email

¾ Click Apply to activate SMTP

7.1.2 SMS alerts

The Console Server uses email-to-SMS services to send SMS alert notifications to mobile devices. Sending SMS via email using SMTP (Simple Mail Transfer Protocol) is much faster than sending text pages via a modem using the TAP Protocol. Almost all mobile phone carriers provide an SMS gateway service that forwards email to mobile phones on their networks. There is also a wide selection of SMS gateway aggregators who provide email to SMS forwarding to phones on any carriers. To use SMTP SMS, the Administrator must configure a valid SMTP server for sending the email:

Page 95 of the Tripp Lite B096-048 user manual — 7. ALERTS AND LOGGING
Page 95 · click to enlarge
Page 95
Tripp Lite B096-048 — 7. ALERTS AND LOGGING diagram (page 95)
Fig. 103

¾ In the SMTP SMS Server field in the Alerts & Logging: SMTP &SMS menu, enter the IP address

of the outgoing mail Server

¾ You may enter a Sender email address which will appear as the “from” address in all email

notifications sent from this Console Server. Some SMS gateway service providers only forward email to SMS when the email has been received from authorized senders. So you may need to assign a specific authorized email address for the Console Server

¾ You may also enter a Username and Password as some SMS gateway service providers use

SMTP servers which require authentication

¾ Similarly, you can specify the Subject Line that will be sent with the email. Generally the email

subject will contain a truncated version of the alert notification message (which is contained in full in the body of the email). However, some SMS gateway service providers require blank subjects or require specific authentication headers to be included in the subject line

¾ Click Apply to activate SMTP

7.1.3 SNMP alerts

The Administrator can configure the Simple Network Management Protocol (SNMP) agent that resides on the Console Server to send Alerts to an SNMP management application:

¾ Select Alerts & LoggingSNMP

¾ Enter the SNMP transport protocol. SNMP is generally a UDP-based protocol though it

infrequently uses TCP instead.

¾ Enter the IP address of the SNMP Manager and the Port to be used for connecting

¾ Select the version being used. The Console Server SNMP agent supports SNMP v1, v2 and v3

¾ Enter the Community name for SNMP v1 or 2c

¾ To configure for SNMP v3 you will need to enter an ID and authentication password and contact

information for the local Administrator (in the Security Name)

¾ Click Apply to activate SNMP

Page 96 of the Tripp Lite B096-048 user manual — 7.2 Activate Alert Events and Notifications
Page 96 · click to enlarge
Page 96
Tripp Lite B096-048 — 7.2 Activate Alert Events and Notifications diagram (page 96)
Fig. 104 · 7.2 Activate Alert Events and Notifications

servers on defined trigger events, as detailed above. The Console Servers also embed the net- snmpd daemon which accept SNMP requests from remote SNMP management servers and provides information on network interface, running processes, disk usage, etc. (refer to Chapter 15.5 Modifying SNMP Configuration for more details)

7.1.4 Nagios Alerts

To notify the central Nagios server of Alerts, NSCA must be enabled under System: Nagios and Nagios must be enabled for each applicable host or port under Serial & Network: Network Hosts or Serial & Network: Serial Ports (refer to Chapter 10)

7.2 Activate Alert Events and Notifications

The Alert facility monitors the status of the Console Server and connected devices. When an alert event is triggered, a notification is emailed to a nominated email address or SMS gateway, or the configured SNMP or Nagios server is notified.

A wide selection of events can be used as the trigger for an alert. These events include:

¾ a user establishing a remote Telnet connecting to a serial port or Host

¾ reaching a nominated low-battery level on a particular UPS or current load levels on a PDU

¾ exceeding a specified temperature or humidity level on an environmental sensor

¾ sensing a particular data pattern on a serial port (e.g. the data stream on a particular serial

console may be monitored for nominated messages coming from the device such as "warning" or "IO error" and send out an alarm when they occur)

power outlet

Page 97 of the Tripp Lite B096-048 user manual — 7.2 Activate Alert Events and Notifications
Page 97 · click to enlarge
Page 97
Tripp Lite B096-048 — 7.2 Activate Alert Events and Notifications diagram (page 97)
Fig. 105 · 7.2 Activate Alert Events and Notifications
¾ Select Alerts & LoggingAlerts which will display all the alerts currently configured. Click Add

7.2.1 Add a new alert

The first step is to specify the alert service that will be used to send notification for this event, who to notify, and what port/host/device is to be monitored:

Tripp Lite B096-048 — 7.2 Activate Alert Events and Notifications diagram (page 97)
Fig. 106 · 7.2 Activate Alert Events and Notifications

¾ At Add a New Alert. enter a Description for this new alert

¾ Nominate the email address for the Email Recipient and/or the SMS Recipient to be notified of

¾ Activate SNMP notification if it is to used for this event

Alert · the alert

Page 98 of the Tripp Lite B096-048 user manual — 7.2 Activate Alert Events and Notifications
Page 98 · click to enlarge
Page 98

¾ Activate Nagios notification if it is to be used for this event. In an SDT Nagios centrally managed

environment, you can check the Nagios alert option. On the trigger condition (for matched patterns, logins, power events and signal changes), an NSCA check "warning" result will be sent to the central Nagios server. This condition is displayed on the Nagios status screen and triggers a notification. This can cause the Nagios central server itself to send out an email or an SMS, page, etc.

¾ Select from the list of all configured serial ports, hosts, power units, monitors and probes which

devices this new alert is to be applied to. Select Applicable Port(s) (serial) and/or Applicable Host(s) and/or Applicable UPS(es) and/or Applicable RPC(s) and/or Applicable EMD(s) and/or Applicable Alarm Sensor(s) that are to be monitored for this alert trigger

7.2.2 Select general alert type

Select the Alert Type (Connection, Signal, Pattern Match, UPS Status or Environment and Power) that is to be monitored. You can configure a selection of different Alert types and any number of specific triggers

Tripp Lite B096-048 — 7.2 Activate Alert Events and Notifications diagram (page 98)
Fig. 107 · 7.2 Activate Alert Events and Notifications

¾ Connection Alert - This alert will be triggered when a user connects or disconnects from the

applicable Host or Serial Port, or when a Slave connects or disconnects from the applicable UPS

¾ Serial Port Signal Alert - This alert will be triggered when the specified signal changes state and

is applicable to serial ports only. You must specify the particular Signal Type (DSR, DCD or CTS) trigger condition that will send a new alert

Page 99 of the Tripp Lite B096-048 user manual — 7.2 Activate Alert Events and Notifications
Page 99 · click to enlarge
Page 99

¾ Serial Port Pattern Match Alert – This alert will be triggered if a regular expression is found in

the serial ports character stream that matches the regular expression you enter in the Pattern field. This alert type will only be applied serial ports

¾ UPS Power Status Alert - This alert will be triggered when the UPS power status changes

between On Line, On Battery, and Low Battery. This alert type will only be applied to UPS’s.

¾ Environment and power alert - Refer to next section for details on selecting and configuring this

7.2.3 Configuring environment and power alert type

This alert type will be applied to any UPS’s, RPC’s and EMD temperature and humidity sensors you have nominated.

Tripp Lite B096-048 — 7.2 Activate Alert Events and Notifications diagram (page 99)
Fig. 108 · 7.2 Activate Alert Events and Notifications

¾ Select Sensor Alert to activate

¾ Specify which Sensor Type to alert on (Temperature, Humidity, Power Load and Battery

¾ Set the levels at which Critical and/or Warning alerts are to be sent. You can also specify

High and/or Low Set Points for sending alerts and the Hysteresis to be applied before resetting off the alerts

Degrees Centigrade for Temperature Amps (Current) for Power Load % (Percentage) for Humidity and Battery Charge

alert type · Charge)

Page 100 of the Tripp Lite B096-048 user manual — 7.3 Remote Log Storage
Page 100 · click to enlarge
Page 100

If you have selected Applicable Alarm Sensor(s) that are to be monitored for this alert event, then you can also set time windows when these sensors will not be monitored (e.g. for a door-open sensor, you may not wish to activate the sensor alert monitoring during the working day)

Tripp Lite B096-048 — 7.3 Remote Log Storage diagram (page 100)
Fig. 109 · 7.3 Remote Log Storage

7.3 Remote Log Storage

Before activating Serial or Network Port Logging on any port or UPS logging, you must specify where those logs are to be saved:

¾ Select the Alerts & Logging: Port Log menu option and specify the Server Type to be used, and

the details to enable log server access

¾ Click Apply

Page 101 of the Tripp Lite B096-048 user manual — 7.4 Serial Port Logging
Page 101 · click to enlarge
Page 101
Tripp Lite B096-048 — 7.4 Serial Port Logging diagram (page 101)
Fig. 110 · 7.4 Serial Port Logging

7.4 Serial Port Logging

In Console Server mode, activity logs of all serial port activity can be maintained. These records are stored on an off-server, or in the Console Server flash memory. Specify which serial ports are to have activities recorded and to what level data is to be logged:

Tripp Lite B096-048 — 7.4 Serial Port Logging diagram (page 101)
Fig. 111 · 7.4 Serial Port Logging
¾ Select Serial & NetworkSerial Port and Edit the port to be logged

¾ Specify the Logging Level of for each port as:

Level 0 Turns off logging for the selected port Level 1 Logs all connection events to the port Level 2 Logs all data transferred to and from the port and all changes in hardware flow control status and all User connection events ¾ Click Apply

Page 102 of the Tripp Lite B096-048 user manual — 7.5 Network TCP or UDP Port Logging
Page 102 · click to enlarge
Page 102

7.5 Network TCP or UDP Port Logging

The Console Servers can also log any access to and communications with network attached Hosts.

¾ For each Host, when you set up the Permitted Services which are authorized to be used, you

also must set up the level of logging that is to be maintained for each service

Tripp Lite B096-048 — 7.5 Network TCP or UDP Port Logging diagram (page 102)
Fig. 112 · 7.5 Network TCP or UDP Port Logging

¾ Specify the logging level that is to be maintained for that particular TDC/UDP port/service on

that particular Host:

Level 0 Turns off logging for the selected TDC/UDP port to the selected Host Level 1 Logs all connection events to the port Level 2 Logs all data transferred to and from the port

¾ Click Add then click Apply

Page 103 of the Tripp Lite B096-048 user manual — 8.1 Remote Power Control (RPC)
Page 103 · click to enlarge
Page 103

POWER & ENVIRONMENTAL MANAGEMENT

Introduction

The B092-016 Console Server and B096-048/016 Console Server Management Switch products embed software that can be used to manage connected Power Distribution Systems (PDU’s), IPMI devices and Uninterruptible Power Supplies (UPS’s) supplied by a number of vendors, and some the environmental monitoring devices. B092-016 Console Server with PowerAlert also embeds Tripp Lite’s PowerAlert software.

8.1 Remote Power Control (RPC)

The Console Server Management Console monitors and controls Remote Power Control (RPC) devices using the embedded PowerMan and NUT open source management tool. RPC’s include power distribution units (PDU’s) and IPMI power devices.

8.1.1 RPC connection

Serial and network connected RPC’s must first be connected to, and configured to communicate with, the Console Server:

¾ For serial RPC’s, connect the PDU to the selected serial port on the Console Server. From the

Serial and Network: Serial Port menu, configure the Common Settings of that port with the RS232 properties required by the PDU (refer to Chapter 4.1.1 Common Settings). Then select RPC as the Device Type

¾ Similarly for each network connected RPC, go to Serial & Network: Network Hosts menu and

configure the RPC as a connected Host

Tripp Lite B096-048 — 8.1 Remote Power Control (RPC) diagram (page 103)
Fig. 113 · 8.1 Remote Power Control (RPC)

¾ Select the Serial & Network: RPC Connections menu. This will display all the RPC connections

that have already been configured

Tripp Lite B096-048 — 8.1 Remote Power Control (RPC) diagram (page 103)
Fig. 114 · 8.1 Remote Power Control (RPC)
Page 104 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 104 · click to enlarge
Page 104

¾ Click Add RPC

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 104)
Fig. 115

¾ Enter a RPC Name and Description for the RPC

¾ In Connected Via, select the pre-configured serial port or the network host address that

connects to the RPC

¾ Select any specific labels you wish to apply to specific RPC Outlets (e.g. the PDU may have 20

outlets connected to 20 powered devices you may wish to identify by name)

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 104)
Fig. 116

¾ Enter the Username and Password used to login into the RPC. Note that these login credentials

are not related the Users and access privileges you will have configured in Serial & Networks: Users & Groups

¾ Check Log Status and specify the Log Rate (minutes between samples) if you wish the status

from this RPC to be logged. These logs can be views from the Status: RPC Status screen

not on the default list, it is simple to add support for more devices. This is covered in Chapter 14: Advanced Configurations

IPMI service processors and BMCs can be configured so all authorized users can use the Management Console to remotely cycle power and reboot computers, even when their operating

¾ Click Apply

Page 105 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 105 · click to enlarge
Page 105

system is unresponsive. To set up IPMI power control, the Administrator first enters the IP address/domain name of the BMC or service processor (e.g. a Dell DRAC) in Serial & Network: Network Hosts. Then in Serial & Network: RPC Connections, the Administrator specifies the RPC Type to be IPMI1.5 or 2.0

8.1.2 RPC alerts

You can now set PDU and IPMI alerts using Alerts & Logging: Alerts (refer to Chapter 7)

8.1.3 RPC status

You can monitor the current status of your network and serially connected PDU’s and IPMI RPC’s

¾ Select the StatusRPC Status menu. A table with the summary status of all connected RPC

hardware will be displayed

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 105)
Fig. 117

¾ Click on View Log or select the RPC Logs menu. You will be presented with a table of the history

and detailed graphical information on the select RPC

¾ Click Manage to query or control the individual power outlet. This will take you to the Manage:

8.1.4 User power management

The Power Manager enables both Users and Administrators to access and control the configured serial and network attached PDU power strips, and servers with embedded IPMI service processors or BMC’s:

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 105)
Fig. 118
¾ Select the ManagePower and the particular Target power device to be controlled (or click
Manage on the StatusRPC Status menu)

Power screen

Page 106 of the Tripp Lite B096-048 user manual — 8.2 Uninterruptible Power Supply Control (UPS)
Page 106 · click to enlarge
Page 106

¾ The outlet status is displayed. You can initiate the desired Action to be taken by selecting the

appropriate icon:

You will only be presented with icons for those operations that are supported by the Target you have selected

8.2 Uninterruptible Power Supply Control (UPS)

The Console Servers manage UPS hardware using Network UPS Tools (refer Section 8.2.6 for an overview of embedded open source Network UPS Tools - NUT software)

8.2.1 Managed UPS connections

A Managed UPS is a UPS that is connected by serial or USB cable or by the network to the Console Server. The Console Server becomes the Master of this UPS, and runs a upsd server to allow other computers that are drawing power through the UPS (Slaves) to monitor its status and take appropriate action (such as shutdown in event of low battery).

Tripp Lite B096-048 — 8.2 Uninterruptible Power Supply Control (UPS) diagram (page 106)
Fig. 119 · 8.2 Uninterruptible Power Supply Control (UPS)

The Console Server may or may not be drawing power through the Managed UPS (see the Configure UPS powering the Console Server section below).

When the UPS's battery power reaches critical, the Console Server signals and waits for Slaves to shutdown, then powers off the UPS.

Serial and network connected UPS’s must first be configured on the Console Server with the relevant serial control ports reserved for UPS usage, or with the UPS allocated as a connected Host:

Show 4 more labels / short text on this page
Power ON · Power OFF · Power Cycle · Power Status
Page 107 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 107 · click to enlarge
Page 107

¾ Select UPS as the Device Type in the Serial & Network: Serial Port menu for each port which

has Master control over a UPS and in the Serial & Network: Network Hosts menu for each network connected UPS (refer to Chapter 4)

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 107)
Fig. 120

No such configuration is required for USB-connected UPS hardware.

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 107)
Fig. 121

¾ Select the Serial & Network: UPS Connections menu. The Managed UPSes section will display

all the UPS connections that have already been configured.

¾ Click Add UPS

Page 108 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 108 · click to enlarge
Page 108
Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 108)
Fig. 122

¾ Enter a UPS Name and Description (optional) and identify if the UPS will be Connected Via USB

or over pre-configured serial port or via HTTP/HTTPS over the preconfigured network Host connection

¾ Enter the UPS login details. This Username and Password is used by Slaves of this UPS (i.e.

other computers that are drawing power through this UPS) to connect to the Console Server for monitoring of the UPS status and shutdown when battery power is low. Monitoring will typically be performed using the upsmon client running on the Slave server. See section 8.5.4 for details on setting up upsmon on Slave servers powered by the UPS

in Serial & NetworksUsers & Groups

¾ If you have multiple UPS’s and require them to be shut down in a specific order, specify the

Shutdown Order for this UPS. This is a positive whole number, or -1. 0s are shut down first, then 1s, 2s, etc. -1s are not shut down at all. Defaults to 0

¾ Select the Driver that will be used to communicate with the UPS. The drop-down menu

presents a full selection of drivers from the latest Network UPS Tools (NUT version 2.2.0) and additional information on compatible UPS hardware can be found at http://www.networkupstools.org/compat/stable.html

¾ Click New Options in Driver Options if you need to set driver-specific options for your selected

NUT driver and hardware combination (more details at http://www.networkupstools.org/doc

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 108)
Fig. 123
Page 109 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 109 · click to enlarge
Page 109

¾ Check Log Status and specify the Log Rate (i.e. minutes between samples) if you wish the status

from this UPS to be logged. These logs can be views from the Status: UPS Status screen

¾ Check Enable Nagios to enable this UPS to be monitored using Nagios central management

You can also customize the upsmon, upsd and upsc settings for this UPS hardware directly from the command line

8.2.2 Configure UPS powering the Console Server

A Monitored UPS is a UPS that is providing the power to the Console Server. The purpose of configuring a Monitored UPS is to provide an opportunity to perform any "last gasp" actions before power is lost during a power failure. This is achieved by placing a script in /etc/config/scripts/ups-shutdown. You may use the /etc/scripts/ups-shutdown as a template. This script is run when then UPS reaches critical battery status.

¾ If the Console Server is drawing power through a Managed UPS that has already been

configured, select Local, enter the Managed UPS Name and check Enabled. The Console Server continues to be the master of this UPS

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 109)
Fig. 124

¾ If the UPS that powers the Console Server is not a Managed UPS for that Console Server, then

the Console Server can still connect to a remote NUT server (upsd) to monitor its status as a Slave. In this case, select Remote, and enter the address, username and password to connect.

¾ Click Apply

Page 110 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 110 · click to enlarge
Page 110
Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 110)
Fig. 125

8.2.3 Configuring powered computers to monitor a Managed UPS

Once you have added a Managed UPS, each server that is drawing power through the UPS should be setup to monitor the UPS status as a Slave. This is done by installing the NUT package on each server, and setting up upsmon to connect to the Console Server.

Refer to the NUT documentation for details on how this is done, specifically sections 13.5 to 13.10. http://eu1.networkupstools.org/doc/2.2.0/INSTALL.html

An example upsmon.conf entry might look like:

MONITOR [email protected] 1 username password Slave

- managedups is the UPS Name of the Managed UPS

- 192.168.0.1 is the IP address of the Console Server

- 1 indicates the server has a single power supply attached to this UPS

- username is the Username of the Managed UPS

Page 111 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 111 · click to enlarge
Page 111

- password is the Password of the Manager UPS

8.2.4 UPS alerts

You can now set UPS alerts using Alerts & Logging: Alerts (refer to Chapter 7)

8.2.5 UPS status

You can monitor the current status of all your Managed or Monitored UPS’s, whether they are on the network or connected serially or via USB:

¾ Select the StatusUPS Status menu and a table with the summary status of all connected UPS

hardware will be displayed

¾ Click on any particular UPS System name in the table and you will be presented with a more

detailed graphical information on the select UPS System

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 111)
Fig. 126

¾ Click on any particular All Data for any UPS System in the table for more status and

configuration information on the select UPS System

¾ Select UPS Logs and you will be presented with the log table of the load, battery charge level,

temperature and other status information from all the Managed and Monitored UPS systems. This information will be logged for all UPS’s which were configured with Log Status checked. The information is also presented graphically

8.2.6 Overview of Network UPS Tools (NUT)

Network UPS Tools (NUT) is a group of open source programs that provide a common interface for monitoring and administering UPS hardware; and ensuring safe shutdowns of the systems which are connected.

Page 112 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 112 · click to enlarge
Page 112

NUT can be configured using the Management Console as described above, or you can configure the tools and manage the UPS’s directly from the command line. This section provides an overview of NUT. You can find full documentation at http://www.networkupstools.org/doc

NUT is built on a networked model with a layered scheme of drivers, server and clients.

1. The driver programs talk directly to the UPS equipment and run on the same host as the NUT network server upsd . Drivers are provided for a wide assortment of equipment from most of the popular UPS vendors and they understand the specific language of each UPS and map it back to a compatibility layer. This means both an expensive "smart" protocol UPS and a simple "power strip" model can be handled transparently.
2. The NUT network server program upsd is responsible for passing status data from the drivers to the client programs via the network. upsd can cache the status from multiple UPS’s and can then serve this status data to many clients. upsd also contains access control features to limit the abilities of the clients (so only authorized hosts may monitor or control the UPS hardware).
3. There are a number of NUT clients that connect to upsd to check on the status of the UPS hardware and do things based on the status. These clients can run on the same host as the NUT server or they can communicate with the NUT server over the network (enabling them to monitor any UPS anywhere).

The upsmon client enables servers that draw power through the UPS (i.e. Slaves of the UPS) to shutdown gracefully when the battery power reaches critical. Additionally, one server is designated the Master of the UPS, and is responsible for shutting down the UPS itself when all Slaves have shut down. Typically, the Master of the UPS is the one connected to the UPS via serial or USB cable.

upsmon can monitor multiple UPS’s, so high-end servers which receive power from multiple UPS’s simultaneously won't initiate a shutdown until the total power situation across all source UPS’s becomes critical.

There also the two status/logging clients, upsc and upslog. The upsc client provides a quick way to poll the status of a UPS. It can be used inside shell scripts and other programs that need UPS status information. upslog is a background service that periodically polls the status of a UPS, writing it to a file.

All these clients run on the Console Server (for Management Console presentations) but they also are run remotely (on locally powered servers and remote monitoring systems).

This layered NUT architecture enables:

ƒ Multiple architecture supportNUT can manage serial and USB-connected models with the same

common interface. SNMP equipment can also be monitored (although at this stage this is still pre- release with experimental drivers and this feature will be added to the embedded UPS tools in future release).

ƒ Multiple clients monitoring one UPS: Multiple systems may monitor a single UPS using only their

network connections. There’s a wide selection of client programs which support monitoring UPS hardware via NUT (Big Sister, Cacti, Nagios, Windows and more). Refer to www.networkupstools.org/client-projects.)

Page 113 of the Tripp Lite B096-048 user manual — 8.3 Environmental Monitoring
Page 113 · click to enlarge
Page 113

So NUT supports the more complex power architectures found in data centers, computer rooms and NOCs where many UPS’s from many vendors power many systems with many clients and each of the larger UPS’s power multiple devices and many of these devices are themselves dual powered.

8.3 Environmental Monitoring

The Environmental Monitoring Device (EMD), model B090-EMD, can be connected to any Console Server serial port and each Console Server can support multiple EMD’s. Each EMD has one temperature and one humidity sensor and one general purpose status sensor which can be connected to a smoke detector, water detector, vibration or open-door sensor.

Tripp Lite B096-048 — 8.3 Environmental Monitoring diagram (page 113)
Fig. 127 · 8.3 Environmental Monitoring

Using the Management Console, Administrators can view the ambient temperature and humidity and set the EMD to automatically send alarms progressively from warning levels to critical alerts.

Tripp Lite B096-048 — 8.3 Environmental Monitoring diagram (page 113)
Fig. 128 · 8.3 Environmental Monitoring
Page 114 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 114 · click to enlarge
Page 114

8.3.1 Connecting the EMD

The Environmental Monitoring Sensor (EMD) connects to any serial port on the Console Server via a special EMD Adapter and standard CAT5 cable. The EMD is powered over this serial connection and communicates using a custom handshake protocol. It is not an RS232 device and should not be connected without the adapter:

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 114)
Fig. 129

¾ Plug the RJ plug on the EMD Adapter (model B090-EMD- ADP) into RJ45 Port on the EMD (model B090-EMD). Then connect the Console Server serial port to the RJ45 port of the EMD Adapter using the provided UTP cable. If the 6 foot (2 meter) UTP cable provided with the EMD is not long enough it can be replaced with a standard Cat5 UTP cable up to 33 feet (10meters) in length (Tripp Lite N002 series cables)

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 114)
Fig. 130

¾ Screw the bare wires on any smoke detector, water

detector, vibration sensor, open-door sensor or general purpose open/close status sensors into the terminals on the EMD:

o B090-WLS Console Server Water Leak Sensor

o B090-DCS Console Server Door Contact Sensor

o B090-VS Console Server Vibration Sensor

o B090-SD-110 Console Server Smoke Detector - 110V

o B090-SD-220 Console Server Smoke Detector - 220V

The EMD can be used only with a Console Server and cannot be connected to standard RS232 serial ports on other appliances.

¾ Select Environmental as the Device Type in the Serial & Network: Serial Port menu for the port

to which the EMD is to be attached. No particular Common Settings are required.

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 114)
Fig. 131

¾ Select the Serial & Network: Environmental menu. This will display all the EMD connections

that have already been configured

¾ Click Apply

Page 115 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 115 · click to enlarge
Page 115
Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 115)
Fig. 132
Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 115)
Fig. 133

¾ Enter a Name and Description for the EMD and select pre-configured serial port that the EMD

will be Connected Via

¾ Provide Labels for each of the two alarms

¾ Check Log Status and specify the Log Rate (minutes between samples) if you wish the status

from this EMD to be logged. These logs can be views from the Status: Environmental Status screen

8.3.2 Environmental alerts

You can now set temperature, humidity and probe status alerts using Alerts & Logging: Alerts (refer to Chapter 7)

8.3.3 Environmental status

You can monitor the current status of all of EMDs and their probes

¾ Click Add · ¾ Click Apply

Page 116 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 116 · click to enlarge
Page 116
¾ Select the StatusEnvironmental Status menu and a table with the summary status of all

connected EMD hardware will be displayed

¾ Click on View Log or select the Environmental Logs menu and you will be presented with a table

and graphical plot of the log history of the select EMD

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 116)
Fig. 134
Page 117 of the Tripp Lite B096-048 user manual — 9.1 Authentication Configuration
Page 117 · click to enlarge
Page 117

AUTHENTICATION

Introduction

The Tripp Lite Console Server is a dedicated Linux computer, and it embodies popular and proven Linux software modules for secure network access (OpenSSH) and communications (OpenSSL) and sophisticated user authentication (PAM, RADIUS, TACACS+ and LDAP).

ƒ This chapter details how the Administrator can use the Management Console to establish remote AAA authentication for all connections to the Console Server and attached serial and network host devices

ƒ This chapter also covers establishing a secure link to the Management Console using HTTPS and using OpenSSL and OpenSSH to establish a secure Administration connection to the Console Server

9.1 Authentication Configuration

Authentication can be performed locally, or remotely using an LDAP, Radius or TACACS+ authentication server. The default authentication method for the Console Server is Local.

Tripp Lite B096-048 — 9.1 Authentication Configuration diagram (page 117)
Fig. 135 · 9.1 Authentication Configuration

Any authentication method that is configured will be used for authentication of any user attempting to log in through Telnet, SSH or the Web Manager to the Console Server and any connected serial port or network host devices.

The Console Server can be configured to the default (Local) or an alternate authentication method (TACACS, RADIUS or LDAP) with the option of a selected order in which local and remote authentication is to be used:

Page 118 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 118 · click to enlarge
Page 118
Local TACACS /RADIUS/LDAPTries local authentication first, falling back to remote if local fails
TACACS /RADIUS/ LDAP LocalTries remote authentication first, falling back to local if remote fails

TACACS /RADIUS/LDAP Down Local: Tries remote authentication first, falling back to local if the remote authentication returns an error condition (e.g. the remote authentication server is down or inaccessible)

9.1.1 Local authentication

¾ Select Serial and NetworkAuthentication and check Local

9.1.2 TACACS authentication

Perform the following procedure to configure the TACACS+ authentication method to be used whenever the Console Server or any of its serial ports or hosts is accessed:

¾ Select Serial and NetworkAuthentication and check TACAS or LocalTACACS or TACACSLocal
Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 118)
Fig. 136

¾ Enter the Server Address (IP or host name) of the remote Authentication/Authorization server.

Multiple remote servers may be specified in a comma-separated list. Each server is tried in succession.

¾ In addition to multiple remote servers, you can also enter for separate lists of

Authentication/Authorization servers and Accounting servers. If no Accounting servers are specified, the Authentication/Authorization servers are used instead.

¾ Enter the Server Password

¾ Click Apply. TACAS+ remote authentication will now be used for all user access to Console

Server and serially or network attached devices

TACACS+ The Terminal Access Controller Access Control System (TACACS+) security protocol is a recent protocol developed by Cisco. It provides detailed accounting information and flexible

¾ Click Apply · or TACACSDownLocal

Page 119 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 119 · click to enlarge
Page 119

administrative control over the authentication and authorization processes. TACACS+ allows for a single access control server (the TACACS+ daemon) to provide authentication, authorization, and accounting services independently. Each service can be tied into its own database to take advantage of other services available on that server or on the network, depending on the capabilities of the daemon. There is a draft RFC detailing this protocol. Further information on configuring remote TACACS+ servers can be found at the following sites:

http://www.cisco.com/en/US/tech/tk59/technologies_tech_note09186a0080094e99.shtml

http://www.cisco.com/en/US/products/sw/secursw/ps4911/products_user_guide_chapter09186a0 0800eb6d6.html

http://cio.cisco.com/univercd/cc/td/doc/product/software/ios113ed/113ed_cr/secur_c/scprt2/sctplu s.htm

9.1.3 RADIUS authentication

Perform the following procedure to configure the RADIUS authentication method to be used whenever the Console Server or any of its serial ports or hosts is accessed:

¾ Select Serial and NetworkAuthentication and check RADIUS or LocalRADIUS or RADIUSLocal
Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 119)
Fig. 137

¾ Enter the Server Address (IP or host name) of the remote Authentication/ Authorization server.

Multiple remote servers may be specified in a comma-separated list. Each server is tried in succession

¾ In addition to multiple remote servers, you can also enter for separate lists of

Authentication/Authorization servers and Accounting servers. If no Accounting servers are specified, the Authentication/Authorization servers are used instead

¾ Enter the Server Password

¾ Click Apply. RADIUS remote authentication will now be used for all user access to Console

Server and serially or network attached devices

RADIUS The Remote Authentication Dial-In User Service (RADIUS) protocol was developed by Livingston Enterprises as an access server authentication and accounting protocol. The RADIUS server can support a variety of methods to authenticate a user. When it is provided with the username and original password given by the user, it can support PPP, PAP or CHAP, UNIX

or RADIUSDownLocal

Page 120 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 120 · click to enlarge
Page 120

login, and other authentication mechanisms. Further information on configuring remote RADIUS servers can be found at the following sites:

http://www.microsoft.com/technet/prodtechnol/windowsserver2003/library/DepKit/d4fe8248-eecd- 49e4-88f6-9e304f97fefc.mspx

http://www.cisco.com/en/US/tech/tk59/technologies_tech_note09186a00800945cc.shtml

http://www.freeradius.org/

9.1.4 LDAP authentication

Perform the following procedure to configure the LDAP authentication method to be used whenever the Console Server or any of its serial ports or hosts is accessed:

¾ Select Serial and NetworkAuthentication and check LDAP or LocalLDAP or LDAPLocal or
Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 120)
Fig. 138

¾ Enter the Server Address (IP or host name) of the remote Authentication server. Multiple

remote servers may be specified in a comma-separated list. Each server is tried in succession.

¾ Enter the Server Password

remote server, i.e., you can't just create the user on your LDAP server and not tell the Console Server about it. You need to add the user account.

¾ Click Apply. LDAP remote authentication will now be used for all user access to Console Server

and serially or network attached devices

LDAPDownLocal

Page 121 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 121 · click to enlarge
Page 121

LDAP The Lightweight Directory Access Protocol (LDAP) is based on the X.500 standard, but is

significantly simpler and more readily adapted to meet custom needs. The core LDAP specifications are all defined in RFCs. LDAP is a protocol used to access information stored in an LDAP server. Further information on configuring remote RADIUS servers can be found at the following sites:

http://www.ldapman.org/articles/intro_to_ldap.html

http://www.ldapman.org/servers.html

http://www.linuxplanet.com/linuxplanet/tutorials/5050/1/

http://www.linuxplanet.com/linuxplanet/tutorials/5074/4/

9.1.5 RADIUS/TACACS user configuration

Users may be added to the local Console Server appliance. If they are not added and they log in via remote AAA, a user will be added for them. This user will not show up in the configurators unless they are specifically added, at which point they are transformed into a completely local user. The newly added user must authenticate via the remote AAA server, and will not have any access if it is down.

If a local user logs in, they may be authenticated/authorized from the remote AAA server, depending on the chosen priority of the remote AAA. A local user's authorization is the union of local and remote privileges.

Example 1:

User A is locally added, and has access to ports 1 and 2. He is also defined on a remote TACACS server, which says he has access to ports 3 and 4. The user may log in with either his local or TACACS password, and will have access to ports 1 through 4. If TACACS is down, he will need to use his local password, and will only be able to access ports 1 and 2.

Example 2:

User B is only defined on the TACACS server, which says he has access to ports 5 and 6. When he attempts to log in, a new user will be created for him, and he will be able to access ports 5 and 6. If the TACACS server is down, he will not have any access.

Example 3:

User C is defined on a RADIUS server only. He has access to all serial ports and network hosts.

Example 4:

User D is locally defined on an appliance using RADIUS for AAA. Even if the user is also defined on the RADIUS server, he will only have access to those serial ports and network hosts he has been authorized to use on the appliance.

If a “no local AAA” option is selected, then root will still be authenticated locally.

Remote users may be added to the admin group via either RADIUS or TACACS. Users may have a set of authorizations set on the remote TACACS server. Users automatically added by RADIUS will have authorization for all resources, whereas those added locally will still need their authorizations specified.

LDAP has not been modified, and will still need locally defined users.

Page 122 of the Tripp Lite B096-048 user manual — 9.2 PAM (Pluggable Authentication Modules)
Page 122 · click to enlarge
Page 122

9.2 PAM (Pluggable Authentication Modules)

The Console Server supports RADIUS, TACACS+ and LDAP for two-factor authentication via PAM (Pluggable Authentication Modules). PAM is a flexible mechanism for authenticating Users. Nowadays, a number of new ways of authenticating users have become popular. The challenge is that each time a new authentication scheme is developed, it requires all the necessary programs (login, ftpd, etc.) to be rewritten to support it.

PAM provides a way to develop programs that are independent of authentication schemes. These programs need "authentication modules" to be attached to them at run-time in order to work. Which authentication module is to be attached is dependent upon the local system setup and is at the discretion of the local Administrator.

The Console Server family supports PAM to which we have added the following modules for remote authentication:

RADIUS - pam_radius_auth (http://www.freeradius.org/pam_radius_auth/)

TACACS+ - pam_tacplus (http://echelon.pl/pubs/pam_tacplus.html)

LDAP - pam_ldap (http://www.padl.com/OSS/pam_ldap.html)

Further modules can be added as required.

Changes may be made to files in /etc/config/pam.d/ which will persist, even if the authentication configurator is run.

¾ Users added on demand:

When a user attempts to log in, but does not already have an account on the Console Server, a new user account will be created. This account will not have any rights, and no password set. They will not appear in the configuration tools.

Automatically added accounts will not be able to log in if the remote servers are unavailable. RADIUS users are currently assumed to have access to all resources, so will only be authorized to log in to the Console Server. RADIUS users will be authorized each time they access a new resource.

¾ Admin rights granted over AAA:

Users may be granted Administrator rights via networked AAA. For TACACS, a priv-lvl of 12 of above indicates an administrator. For RADIUS, administrators are indicated via the Framed Filter ID. (See the example configuration files below, for example.)

¾ Authorization via TACACS for both serial ports and host access:

Permission to access resources may be granted via TACACS by indicating an appliance and a port or networked host the user may access. (See the example configuration files below, for example.)

TACACS Example:

user = tim {

service = raccess {

priv-lvl = 11 · port1 = xxxxx/port02

Page 123 of the Tripp Lite B096-048 user manual — 9.3 Secure Management Console Access
Page 123 · click to enlarge
Page 123

port2 = 192.168.254.145/port05

global = cleartext mit

RADIUS Example:

paul Cleartext-Password := "luap"

Framed-Filter-Id=":group_name=admin"

The list of groups may include any number of entries separated by a comma. If the admin group is included, the user will be made an Administrator.

If there is already a Framed-Filter-Id, simply add the list of group_names after the existing entries, including the separating colon ":".

9.3 Secure Management Console Access

Selecting HTTPS Server in SystemServices enables the Administrator to establish a secure browser connection Management Console:
Tripp Lite B096-048 — 9.3 Secure Management Console Access diagram (page 123)
Fig. 139 · 9.3 Secure Management Console Access

¾ Activate your preferred browser and enter https:// IP address. For example, if the Console

Server has been set up with an IP address of 200.122.0.12, you need to type https:// 200.122.0.12 in your address bar

¾ Your browser may respond with a message that verifies the security certificate is valid but notes

that it is not necessarily verified by a certifying authority. To proceed you need to click yes if you are using Internet Explorer or select accept this certificate permanently (or temporarily) if you are using Mozilla Firefox.

¾ You will then be prompted for the Administrator account and password as normal.

When you have a secure HTTPS connection in place, the SSL secured icon will appear at the bottom of the browser screen. You can verify the level of encryption in place by clicking on this icon.

Show 4 more labels / short text on this page
} · } · Service-Type = Framed-User, · Fall-Through = No,
Page 124 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 124 · click to enlarge
Page 124

When you first enable and connect via HTTPS, it is normal that you may receive a certificate warning. The default SSL certificate in your Console Server is embedded during testing and is not signed by a recognized third party certificate authority. Rather, it is signed by our own signing authority. These warnings do not affect the encryption protection you have against eavesdroppers.

13. Advanced
Page 125 of the Tripp Lite B096-048 user manual — 10.1 Nagios Overview
Page 125 · click to enlarge
Page 125

NAGIOS INTEGRATION

Introduction

Nagios is a powerful, highly extensible open source tool for monitoring network hosts and services. The core Nagios software package will typically be installed on a server or virtual server, the central Nagios server.

Tripp Lite Console Servers can operate in conjunction with a central/upstream Nagios server to provide distributing monitoring of attached network hosts and serial devices. The Console Servers can embed the NSCA (Nagios Service Checks Acceptor) and NRPE (Nagios Remote Plug-in Executor) add-ons. This allows them to communicate with the central Nagios server, eliminating the need for a dedicated Slave Nagios server at remote sites.

The Console Servers embed a basic set of distributed monitoring add-ons and can be uploaded with additional customizable distributed monitoring.

distributed monitoring server capacity only. In this case and if you are already familiar with Nagios, skip ahead to section 10.3.

10.1 Nagios Overview

Nagios provides central monitoring of the hosts and services in your distributed network. Nagios is freely downloadable, open source software. This section offers a quick background of Nagios and its capabilities. A complete overview, FAQ and comprehensive documentation are available at: http://www.nagios.org

Nagios forms the core of many leading commercial system management solutions such as GroundWork: http://www.groundworkopensource.com

Nagios takes some time to install and configure, but once it is up and running, it provides an outstanding network monitoring system. With Nagios you can:

ƒ Display tables showing the status of each monitored server and network service in real time

ƒ Use a wide range of freely available plug-ins to make detailed checks of specific services, e.g., don't just check if a database is accepting network connections, check that it can actually validate requests and return real data

ƒ Display warnings and send warning e-mails, pager or SMS alerts when a service failure or degradation is detected

ƒ Assign contact groups who are responsible for specific services in specific time frames

Page 126 of the Tripp Lite B096-048 user manual — 10.2.1 Set up central Nagios server
Page 126 · click to enlarge
Page 126

10.2 Central management

The Nagios solution has three parts: the Central Nagios server, Distributed Console Servers and the SDT for Nagios software.

Tripp Lite B096-048 — 10.2 Central management diagram (page 126)
Fig. 140 · 10.2 Central management

ƒ A vanilla Nagios 2.x or 3.x installation (typically on a Linux server) ƒ Generally running on a blade, PC, virtual machine, etc. at a central location ƒ Runs a web server that displays the Nagios GUI ƒ Imports configuration from distributed Console Servers

ƒ B096-016 / B096-048 or B092-016 Console Servers ƒ Serial and network hosts are attached to each Console Server ƒ Each runs Nagios plug-ins, NRPE and NSCA add-ons, but not a full Nagios server

ƒ Typically a client PC, laptop, etc. running Windows, Linux or Mac OS X ƒ Runs Tripp Lite SDT Connector client software 1.5.0 or later ƒ Connect to the central Nagios server web UI to view status of monitored hosts and serial devices ƒ Then use SDT Connector to connect through the distributed Console Servers, to manage monitored hosts and serial devices

10.2.1 Set up central Nagios server

The Nagios server software is available for most major distributors of Linux using the standard package management tools. Your distributor will have documentation available on how to install Nagios. This is usually the quickest and simplest way to get up and running.

Central Nagios server · Distributed Console Servers · Clients

Page 127 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 127 · click to enlarge
Page 127

You will also require a web server such as Apache to display the Nagios web UI (and this may be installed automatically as a dependency of the Nagios packages).

Alternatively, you may wish to download the Nagios source code directly from the Nagios website, and build and install the software from scratch. The Nagios website (http://www.nagios.org) has several Quick Start Guides that walk through this process.

Once you are able to browse to your Nagios server and see its web UI and the local services it monitors by default, you are ready to continue.

10.2.2 Set up distributed Console Servers

This section provides a brief walk-through on configuring a single Console Server to monitor the status of one attached network host (a Windows IIS server running HTTP and HTTPS services) and one serially attached device (the console port of a network router), and to send alerts back to the Nagios server when an administrator connects to the router or IIS server.

While this walk-through provides an example, details of the configuration options are described in the next section. This walk-through also assumes the network host and serial devices are already physically connected to the Console Server. First step is to set up the Nagios features on the Console Server:

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 127)
Fig. 141

¾ Browse the Console Server and select System: Nagios on the Console Server Management

Console. Check Nagios service Enabled

¾ Enter the Host Name and the Nagios Host Address (i.e. IP address) that the central Nagios

server will use to contact the distributed Console Server

¾ Enter the IP address that the distributed Console Server will use to contact the central Nagios

server in Nagios Server Address

¾ Enter the IP address that the clients running SDT Connector will use to connect through the

distributed Console Servers in SDT Gateway address

¾ Check Prefer NRPE, NRPE Enabled and NRPE Command Arguments

Page 128 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 128 · click to enlarge
Page 128

¾ Check NSCA Enabled, choose an NSCA Encryption Method and enter and confirm an NSCA

Secret. Remember these details as you will need them later on. For NSCA Interval, enter 5

¾ Click Apply.

Next, configure the attached Window network host and specify the services you will be checking with Nagios (HTTP and HTTPS):

¾ Select Network Hosts from the Serial & Network menu and click Add Host.

¾ Enter the IP Address/DNS Name of the network server, (e.g.: 192.168.1.10) and enter a

Description, (e.g.: Windows 2003 IIS Server)

¾ Remove all Permitted Services. This server will be accessible using Terminal Services, so check

TCP, Port 3389 and log level 1 and click Add. It is important to remove and re-add the service to enable logging

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 128)
Fig. 142

¾ Scroll down to Nagios Settings and check Enable Nagios

¾ Click New Check and select Check Ping. Click check-host-alive

¾ Click New Check and select Check Permitted TCP. Select Port 3389

¾ Click New Check and select Check TCP. Select Port 80

¾ Click New Check and select Check TCP. Select Port 443

Similarly, configure the serial port to the router to be monitored by Nagios:

¾ Select Serial Port from the Serial & Network menu

¾ Locate the serial port that has the router console port attached and click Edit

¾ Ensure the serial port settings under Common Settings are correct and match the attached

¾ Click Console Server Mode and select Logging Level 1

¾ Check Telnet (SSH access is not required, as SDT Connector is used to secure the otherwise

¾ Scroll down to Nagios Settings and check Enable Nagios

¾ Check Port Log and Serial Status

¾ Click Apply · router’s console port · unsecured Telnet connection)

Page 129 of the Tripp Lite B096-048 user manual — 10.3 Configuring Nagios distributed monitoring
Page 129 · click to enlarge
Page 129

Now set the Console Server to send alerts to the Nagios server

¾ Select Alerts from the Alerts & Logging menu and click Add Alert

¾ In Description enterAdministrator connection

¾ Check Nagios (NSCA)

¾ In Applicable Ports check the serial port that has the router console port attached. In Applicable

Hosts check the IP address/DNS name of the IIS server

¾ Click Connection Alert

Lastly, add a User for the client running SDT Connector:

¾ Select Users & Groups from the Serial & Network menu

¾ Click Add User

¾ In Username , entersdtnagiosuser , then enter and confirm a Password

¾ In Accessible Hosts click the IP address/DNS name of the IIS server. In Accessible Ports click the

serial port that has the router console port attached

10.3 Configuring Nagios distributed monitoring

To activate the Console Server’s Nagios distributed monitoring:

ƒ Nagios integration must be enabled and a path established to the central/upstream Nagios server

ƒ If the Console Server is to periodically report on Nagios-monitored services, then the NSCA client embedded in the Console Server must be configured: the NSCA program enables scheduled check- ins with the remote Nagios server and is used to send passive check results across the network to the remote server

ƒ If the Nagios server is to actively request status updates from the Console Server, then the NRPE server embedded in the Console Server must be configured – the NRPE server is the Nagios daemon for executing plug-ins on remote hosts

ƒ Each of the Serial Ports and each of the Hosts connected to the Console Server which are to be monitored must have Nagios enabled and any specific Nagios checks configured

ƒ Lastly the central/upstream Nagios monitoring host must be configured

10.3.1 Enable Nagios on the Console Server

¾ Select SystemNagios on the Console Server Management Console and tick the Nagios service
Show 4 more labels / short text on this page
¾ Click Apply · ¾ Click Apply · ¾ Click Apply · Enabled
Page 130 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 130 · click to enlarge
Page 130
Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 130)
Fig. 143

¾ Enter the Nagios Host Name that the Console Server will be referred to in the Nagios central

server – this will be generated from local System Name (entered in System: Administration) if unspecified

¾ In Nagios Host Address, enter the IP address or DNS name that the upstream Nagios server will

use to reach the Console Server – if unspecified this will default to the first network port’s IP as entered in System: IP)

¾ In Nagios Server Address, enter the IP address or DNS name that the Console Server will use to

reach the upstream Nagios monitoring server

¾ Check the Disable SDT Nagios Extensions option if you wish to disable the SDT Connector

integration with your Nagios server at the head end – this would only be checked if you want to run a vanilla Nagios monitoring

¾ If not, enter the IP address or DNS name the SDT Nagios clients will use to reach the Console

Server in SDT Gateway Address

¾ When NRPE and NSCA are both enabled, NSCA is preferred method for communicating with the

upstream Nagios server – check Prefer NRPE to use NRPE whenever possible (i.e. for all communication except for alerts)

Page 131 of the Tripp Lite B096-048 user manual — ¾ Select System: Nagios and check NRPE Enabled
Page 131 · click to enlarge
Page 131

10.3.2 Enable NRPE monitoring

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 131)
Fig. 144

Enabling NRPE allows you to execute plug-ins (such as check_tcp and check_ping) on the remote Console Server to monitor serial or network attached remote servers. This will offload CPU load from the upstream Nagios monitoring machine which is especially valuable if you are monitoring hundreds or thousands of hosts. To enable NRPE:

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 131)
Fig. 145

¾ Select System: Nagios and check NRPE Enabled

¾ Enter the details for the user connection to the upstream Nagios monitoring server. Again, refer

to the sample Nagios configuration example below for details of configuring specific NRPE checks

By default, the Console Server will accept a connection between the upstream Nagios monitoring server and the NRPE server with SSL encryption, without SSL, or tunneled through SSH. The security for the connection is configured at the Nagios server.

Page 132 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 132 · click to enlarge
Page 132

10.3.3 Enable NSCA monitoring

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 132)
Fig. 146

NSCA is the mechanism that allows you to send passive check results from the remote Console Server to the Nagios daemon running on the monitoring server. To enable NSCA:

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 132)
Fig. 147
¾ Select SystemNagios and check NSCA Enabled

¾ Select the Encryption to be used from the drop-down menu, then enter a Secret password and

specify a check Interval

¾ Refer the sample Nagios configuration section below for some examples of configuring specific

10.3.4 Configure selected Serial Ports for Nagios monitoring

The individual Serial Ports connected to the Console Server to be monitored must be configured for Nagios checks. Refer to Chapter 4.4: Network Host Configuration for details on enabling Nagios monitoring for Hosts that are network connected to the Console Server. To enable Nagios to monitor a device connected to the Console Server serial port:

¾ Select Serial & NetworkSerial Port and click Edit on the serial Port # to be monitored

NSCA checks

Page 133 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 133 · click to enlarge
Page 133

¾ Select Enable Nagios, specify the name of the device on the upstream server and determine the

check to be run on this port. Serial Status monitors the handshaking lines on the serial port and Check Port monitors the data logged for the serial port

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 133)
Fig. 148

10.3.5 Configure selected Network Hosts for Nagios monitoring

The individual Network Hosts connected to the Console Server that is to be monitored must also be configured for Nagios checks:

¾ Select Serial & NetworkNetwork Port and click Edit on the Network Host to be monitored
Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 133)
Fig. 149

¾ Select Enable Nagios, specify the name of the device as it will appear on the upstream Nagios

¾ Click New Check to add a specific check which will be run on this host

¾ Select Check Permitted TCP/UDP to monitor a service that you have previously added as a

¾ Select Check TCP/UDP to specify a service port that you wish to monitor, but do not wish to

allow external (SDT Connector) access

¾ Select Check TCP to monitor

server · Permitted Service

Page 134 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 134 · click to enlarge
Page 134

¾ The Nagios Check nominated as the check-host-alive check is used to determine whether the

network host itself is up or down

¾ Typically this will be Check Ping – although in some cases the host will be configured not to

¾ If no check-host-alive check is selected, the host will always be assumed to be up

¾ You may deselect check-host-alive by clicking Clear check-host-alive

¾ If required, customize the selected Nagios Checks to use custom arguments

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 134)
Fig. 150

10.3.6 Configure the upstream Nagios monitoring host

Refer to the Nagios documentation (http://www.nagios.org/docs/) for configuring the upstream server:

¾ The section entitled Distributed Monitoring steps through what is needed to configure NSCA on

the upstream server (under Central Server Configuration)

¾ NRPE Documentation, which has been recently added, steps through configuring NRPE on the

upstream server http://nagios.sourceforge.net/docs/nrpe/NRPE.pdf

At this stage, Nagios at the upstream monitoring server is configured, and individual serial port and network host connections on the Console Server are configured for Nagios monitoring. If NSCA is enabled, each selected check will be executed once over the period of the check interval. If NRPE is enabled, then the upstream server will be able to request status updates under its own scheduling.

respond to pings · ¾ Click Apply

Page 135 of the Tripp Lite B096-048 user manual — 10.4 Advanced Distributed Monitoring Configuration
Page 135 · click to enlarge
Page 135

10.4 Advanced Distributed Monitoring Configuration

10.4.1 Sample Nagios configuration

An example configuration for Nagios is listed below. It shows how to set up a remote Console Server to monitor a single host, with both network and serial connections. Each check has two configurations, one for NRPE and one for NSCA. In practice, these would be combined into a single check which uses NSCA as a primary method and falling back to NRPE if a check were late. For details, see the Nagios documentation (http://www.nagios.org/docs/) on Service and Host Freshness Checks.

; Host definitions ; ; Console Server define host{ use generic-host host_name tripplite alias Console Server address 192.168.254.147 } ; Managed Host define host{ use generic-host host_name server alias server address 192.168.254.227 } ; NRPE daemon on gateway define command { command_name check_nrpe_daemon command_line $USER1$/check_nrpe -H 192.168.254.147 -p 5666 } define service { service_description NRPE Daemon host_name tripplite use generic-service check_command check_nrpe_daemon } ; Serial Status define command { command_name check_serial_status command_line $USER1$/check_nrpe -H 192.168.254.147 -p 5666 -c check_serial_$HOSTNAME$ } define service {

Page 136 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 136 · click to enlarge
Page 136

service_description Serial Status host_name server use generic-service check_command check_serial_status } define service { service_description serial-signals-server host_name server use generic-service check_command check_serial_status active_checks_enabled 0 passive_checks_enabled 1 } define servicedependency{ name tripplite_nrpe_daemon_dep host_name tripplite dependent_host_name server dependent_service_description Serial Status service_description NRPE Daemon execution_failure_criteria w,u,c } ; Port Log define command{ command_name check_port_log command_line $USER1$/check_nrpe -H 192.168.254.147 -p 5666 -c port_log_$HOSTNAME$ } define service { service_description Port Log host_name server use generic-service check_command check_port_log } define service { service_description port-log-server host_name server use generic-service check_command check_port_log active_checks_enabled 0 passive_checks_enabled 1 } define servicedependency{ name tripplite_nrpe_daemon_dep

Page 137 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 137 · click to enlarge
Page 137

host_name tripplite dependent_host_name server dependent_service_description Port Log service_description NRPE Daemon execution_failure_criteria w,u,c } ; Ping define command{ command_name check_ping_via_tripplite command_line $USER1$/check_nrpe -H 192.168.254.147 -p 5666 -c host_ping_$HOSTNAME$ } define service { service_description Host Ping host_name server use generic-service check_command check_ping_via_tripplite } define service { service_description host-ping-server host_name server use generic-service check_command check_ping_via_tripplite active_checks_enabled 0 passive_checks_enabled 1 } define servicedependency{ name tripplite_nrpe_daemon_dep host_name tripplite dependent_host_name server dependent_service_description Host Ping service_description NRPE Daemon execution_failure_criteria w,u,c } ; SSH Port define command{ command_name check_conn_via_tripplite command_line $USER1$/check_nrpe -H 192.168.254.147 -p 5666 -c host_$HOSTNAME$_$ARG1$_$ARG2$ } define service { service_description SSH Port host_name server

Page 138 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 138 · click to enlarge
Page 138

use generic-service check_command check_conn_via_tripplite!tcp!22 } define service { service_description host-port-tcp-22-server ; host-port-<protocol>-<port>-<host> host_name server use generic-service check_command check_conn_via_tripplite!tcp!22 active_checks_enabled 0 passive_checks_enabled 1 } define servicedependency{ name tripplite_nrpe_daemon_dep host_name tripplite dependent_host_name server dependent_service_description SSH Port service_description NRPE Daemon execution_failure_criteria w,u,c } 10.4.2 Basic Nagios plug-ins

Plug-ins are compiled executables or scripts that can be scheduled to be run on the Console Server to check the status of a connected host or service. This status is then communicated to the upstream Nagios server which uses the results to monitor the current status of the distributed network. Each Console Server is preconfigured with a selection of the checks that are part of the Nagios plug-ins package:

check_tcp and check_udp are used to check open ports on network hosts

check_ping is used to check network host availability

check_nrpe is used to execute arbitrary plug-ins in other devices

Each Console Server is also preconfigured with two checks that are specific to the Console Server:

check_serial_signals is used to monitor the handshaking lines on the serial ports

check_port_log is used to monitor the data logged for a serial port.

10.4.3 Additional plug-ins

Additional Nagios plug-ins (listed below) are available for all the Tripp Lite Console Servers:

Page 139 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 139 · click to enlarge
Page 139

check_apt check_by_ssh check_clamd check_dig check_dns check_dummy check_fping check_ftp check_game check_hpjd

check_http check_imap check_jabber check_ldap check_load check_mrtg check_mrtgtraf check_nagios check_nntp check_nntps

check_nt check_ntp check_nwstat check_overcr check_ping check_pop check_procs check_real check_simap check_smtp

check_snmp check_spop check_ssh check_ssmtp check_swap check_tcp check_time check_udp check_ups check_users

There also are bash scripts which can be downloaded and run (primarily check_log.sh).

¾ To configure additional checks, the downloaded plug-in program must be saved in the tftp

addins directory on the USB flash and the downloaded text plug-in file saved in /etc/config

¾ To enable these new additional checks, you select Serial&Network: Network Port, then you Edit

the Network Host to be monitored, and select New Checks. The additional check option will have been included in the updated Nagios Checks list. You can again customize the arguments

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 139)
Fig. 151
Page 140 of the Tripp Lite B096-048 user manual — 11.1 System Administration and Reset
Page 140 · click to enlarge
Page 140

11. SYSTEM MANAGEMENT

Introduction

This chapter describes how the Administrator can perform a range of general system administration and configuration tasks on the Console Server, such as:

ƒ Applying Soft and Hard Resets to the gateway

ƒ Re-flashing the firmware

ƒ Configuring the Date, Time and NTP

System administration and configuration tasks covered elsewhere include:

ƒ Resetting the System Password and entering a new System Name and Description for the Console Server (Chapter 3.2)

ƒ Setting the Console Server’s System IP Address (Chapter 3. 3)

ƒ Setting the permitted Services used to access the Console Server (Chapter 3.4)

ƒ Setting up OoB Dial-in (Chapter 5)

11.1 System Administration and Reset

The Administrator can reboot or reset the Console Server to default settings.

A soft reset is performed by:

¾ Selecting Reboot in the System: Administration menu and clicking Apply

Tripp Lite B096-048 — 11.1 System Administration and Reset diagram (page 140)
Fig. 152 · 11.1 System Administration and Reset

The Console Server reboots with all settings (e.g., the assigned network IP address) preserved. However this soft reset does disconnect all Users and ends any SSH sessions that had been established.

A soft reset will also be performed when you switch OFF power to the Console Server, and then switch the power back ON. However, if you cycle the power while the unit is writing to flash, you could corrupt or lose data. Therefore, the software reboot is the safer option.

A hard erase (hard reset) is performed by:

¾ Pushing the Erase button on the rear panel twice. A ball point pen or bent paper clip is a suitable

tool for performing this procedure. Do not use a graphite pencil. Depress the button gently twice (within a 5 second period) while the unit is powered ON.

Page 141 of the Tripp Lite B096-048 user manual — 11.2 Upgrade Firmware
Page 141 · click to enlarge
Page 141

This will reset the Console Server back to its factory default settings and clear the Console Server’s stored configuration information.

The hard erase will clear all custom settings and return the unit back to factory default settings (i.e. the IP address will be reset to 192.168.0.1).

You will be prompted to log in and must enter the default administration username and administration password:

Usernameroot
Passworddefault

11.2 Upgrade Firmware

Before upgrading, check if you are already running the most current firmware in your Console Server. Your Console Server will not allow you to upgrade to the same or an earlier version.

ƒ The Firmware version is displayed in the header of each page

Tripp Lite B096-048 — 11.2 Upgrade Firmware diagram (page 141)
Fig. 153 · 11.2 Upgrade Firmware
¾ Or select StatusSupport Report and note the Firmware Version

¾ To upgrade, you must first download the latest firmware image from

http://www.tripplite.com/EN/support/downloads/driver-firmware-downloads.cfm

¾ Save this downloaded firmware image file on to a system on the same subnet as the Console

¾ Also download and read the release_notes.txt for the latest information

¾ To then upload the firmware image file to your Console Server, select System: Firmware

Tripp Lite B096-048 — 11.2 Upgrade Firmware diagram (page 141)
Fig. 154 · 11.2 Upgrade Firmware

Server

Page 142 of the Tripp Lite B096-048 user manual — 11.3 Configure Date and Time
Page 142 · click to enlarge
Page 142

¾ Specify the address and name of the downloaded Firmware Upgrade File, or Browse the local

subnet and locate the downloaded file

¾ Click Apply and the Console Server appliance will undertake a soft reboot and commence

upgrading the firmware. This process will take several minutes

¾ After the firmware upgrade has completed, click here to return to the Management Console.

Your Console Server will have retained all its pre-upgrade configuration information

11.3 Configure Date and Time

It is recommended that you set the local Date and Time in the Console Server as soon as it is configured. Features like Syslog and NFS logging use the system time for time-stamping log entries, while certificate generation depends on a correct Timestamp to check the validity period of the certificate.

Tripp Lite B096-048 — 11.3 Configure Date and Time diagram (page 142)
Fig. 155 · 11.3 Configure Date and Time
¾ Select the SystemDate & Time menu option

¾ Manually set the Year, Month, Day, Hour and Minute using the Date and Time selection boxes,

The Console Server can synchronize its system time with a remote time server using the Network Time Protocol (NTP). Configuring with the NTP time server ensures that the Console Server clock will be accurate soon after the Internet connection is established. Also, if NTP is not used, the system clock will be reset randomly every time the Console Server is powered up. To set the system time using NTP:

¾ Select the Enable NTP checkbox on the Network Time Protocol page

¾ Enter the IP address of the remote NTP Server and click Apply

Specify your local time zone so the system clock can show local time (and not UTP):

¾ Set your appropriate region/locality in the Time Zone selection box and click Apply

then click Apply

Page 143 of the Tripp Lite B096-048 user manual — 12.2 Statistics
Page 143 · click to enlarge
Page 143

12. STATUS REPORTS

Introduction

This chapter describes the selection of status reports that are available for review:

ƒ Port Access and Active Users

12.1 Port Access and Active Users

The Administrator can see which Users have access privileges to each serial port:

¾ Select the StatusPort Access
Tripp Lite B096-048 — 12.1 Port Access and Active Users diagram (page 143)
Fig. 156 · 12.1 Port Access and Active Users

The Administrator can also see the current status to identify which Users have an active session on each port:

ƒ Select the StatusActive Users

12.2 Statistics

The Statistics report provides a snapshot of the data traffic and other activities and operations of your Console Server

Show 4 more labels / short text on this page
ƒ Statistics · ƒ Support Reports · ƒ Syslog · ƒ UPS Status
Page 144 of the Tripp Lite B096-048 user manual — 12.4 Syslog
Page 144 · click to enlarge
Page 144
Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 144)
Fig. 157

12.3 Support Reports

The Support Report provides useful status information that will assist the Tripp Lite technical support team to resolve any issues you may experience with your Console Server.

If you do experience an issue and have to contact Support, ensure you include the Support Report with your email support request. The Support Report should be generated when the issue is occurring, and attached in plain text format.

Tripp Lite B096-048 — 12.3 Support Reports diagram (page 144)
Fig. 158 · 12.3 Support Reports
¾ Select the StatusSupport Report menu option and you will be presented with a snapshot of

your Console Server’s status

¾ Save the file as a text file and attach it to your support email

12.4 Syslog

The Linux System Logger maintains a record of all system messages and errors:

¾ Select StatusSyslog
Page 145 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 145 · click to enlarge
Page 145

The syslog record can be redirected to a remote Syslog Server:

¾ Enter the remote Syslog Server address and port details and then click Apply

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 145)
Fig. 159

To view the local Syslog file:

¾ Select Alerts & LoggingSyslog

To make it easier to find information in the local Syslog file, a pattern matching filter tool is provided.

¾ Specify the Match Pattern that is to be searched for (e.g. the search for Mount is shown below)

and click Apply. The Syslog will then be represented with only those entries that actually include the specified pattern

Remote System Logging · Local System Logging

Page 146 of the Tripp Lite B096-048 user manual — 13.2 Port & Host Management
Page 146 · click to enlarge
Page 146

13. MANAGEMENT

Introduction

The Console Server Management Console has a number of reports and tools that can be accessed by both Administrators and Users:

ƒ Access and control configured devices

ƒ View serial port logs and host logs

ƒ Use SDT Connector or the java terminal to access serially attached consoles

13.1 Device Management

To display all the connected Serial devices, Network Hosts and Power devices:

¾ Select ManageDevices. By selecting the Serial/ Network/ Power item, the display will be

reduced to only those devices

Tripp Lite B096-048 — 13.1 Device Management diagram (page 146)
Fig. 160 · 13.1 Device Management

The user can take a range of actions on each of these Serial/Network/Power devices by selecting the Action icon or the related Manage menu item. Selecting the Manager Power icon or the Manage: Power menu is covered in Chapter 8.

13.2 Port & Host Management

Administrator and Users can view logs of data transfers to connected devices.

¾ Select ManagePort Logs and the serial Port # to be displayed

ƒ Power control

Page 147 of the Tripp Lite B096-048 user manual — 13.4 Serial Port Terminal Connection
Page 147 · click to enlarge
Page 147
Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 147)
Fig. 161

¾ To display Host logs select Manage: Host Logs and the Host to be displayed

13.3 Power Management

Administrator and Users can access and manage the connected power devices.

¾ Select ManagePower

13.4 Serial Port Terminal Connection

Administrator and Users can communicate directly with the Console Server command line and with devices attached to the Console Server serial ports using SDT Connector and their local Telnet client, or using a java terminal in their browser

¾ Select ManageTerminal
Page 148 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 148 · click to enlarge
Page 148
Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 148)
Fig. 162

ƒ Click Connect to SDT Connector to access the Console Server command line shell or the serial ports via SDT Connector. This will activate the SDT Connector client on the computer you are browsing and load your local Telnet client to connect to the command line or serial port using SSH

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 148)
Fig. 163

the Console Server must be added as a gateway, as detailed in Chapter 6

The alternative to using SDT Connector and your local Telnet client is to download the open source jcterm java terminal applet into your browser in order to connect to the Console Server and attached serial port devices. However jcterm does have some JRE compatibility issues which may prevent it from loading.

¾ Select ManageTerminal. The jcterm java applet is downloaded from the Console Server to your

browser and the virtual terminal will be displayed

¾ Select File -> Open SHELL Session from the jcterm menu to access the command line using SSH

Page 149 of the Tripp Lite B096-048 user manual — 13.5 Remote Console Access (B092-016 only)
Page 149 · click to enlarge
Page 149

¾ To access the Console Server command line, enter the gateway’s TCP address (e.g.

192.168.254.198) as hostname and the Username (e.g. [email protected]). Then enter the Password

¾ To access the Console Server's serial ports, append :serial to the username. For example, with

the gateway’s TCP address of 192.168.254.198, and the Username of root, enter root:[email protected]. Then enter Password and select the TCP Port address for the serial port to be accessed. By default 3001 is selected (i.e. Port 1). To access Port 4, this must be changed to 3004 for the Username

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 149)
Fig. 164

13.5 Remote Console Access (B092-016 only)

Administrator and Users can also connect to the B092-016 Console Server with PowerAlert remotely (as if they were plugged in locally to the KVM connectors on the B092-016). This connection will enable the remote users to run the PowerAlert software and the other thin client programs (refer to Chapter 16) embedded in the Console Server:

ƒ Select ManageKVM Console Server
Tripp Lite B096-048 — 13.5 Remote Console Access (B092-016 only) diagram (page 149)
Fig. 165 · 13.5 Remote Console Access (B092-016 only)

ƒ Click Standard VNC Remote control and a VNC Java applet will be loaded into your browser to connect to the B092-016 Console Server. Then log in to the VNC applet and the Console Server (refer to Chapter 16.3 for more details)

Page 150 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 150 · click to enlarge
Page 150
Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 150)
Fig. 166
Page 151 of the Tripp Lite B096-048 user manual — Introduction
Page 151 · click to enlarge
Page 151

14. BASIC CONFIGURATION - LINUX COMMANDS

Introduction

For those who prefer to configure their Console Server at the Linux command line level (rather than use a browser and the Management Console), this chapter describes how to get command line access and use the config tool to manage the system and configure the ports, etc. from the command line:

ƒ Administration Configuration (System Settings and Authentication Configuration)

ƒ Date and Time Configuration (Manually Change Clock Settings and Network Time

ƒ Network Configuration (Static and DHCP IP Configuration, Dial-in Configuration and

ƒ Serial Port Configuration (Serial Port Settings, Supported Protocol Configuration,

Users and Trusted Networks)

ƒ Event Logging Configuration (Remote Serial Port Log Storage and Alert

The config documentation in this chapter walks through the basic configuration (similar to what can be done with the Management Console). For advanced and custom configurations using other standard commands, refer to the next chapter, Advanced Configuration.

Since the Console Server runs a standard Linux kernel, it is also possible to configure it using other standard Linux and Busybox commands and applications as described in the last section of this chapter. However, doing this will not always guarantee these changes are permanent.

This chapter is not intended to teach you Linux. We assume you already have a certain level of understanding before you execute Linux kernel-level commands.

Protocol Time Zone) · Services Configuration) · Configuration)

Page 152 of the Tripp Lite B096-048 user manual — Description
Page 152 · click to enlarge
Page 152

14.1 The Linux Command line

¾ Power up the Console Server and connect the “terminal” device:

o If you are connecting using the serial line, plug a serial cable between the Console

Server local DB-9 port and terminal device. Configure the serial connection of the “terminal” device/program you are using to 115200bps, 8 data bits, no parity and one stop bit. If you are using a program running on a Windows computer as the terminal device, then the cable is made up from a Cat5 UTP cable and two DB-9 to RJ-45 adapters o If you are connecting over the LAN, you will need to interconnect the Ethernet ports

and direct your terminal emulator program to the IP address of the Console Server (192.168.0.1 by default)

¾ Log on to the Console Server by pressing ‘return’ a few times. The Console Server will

request a username and password. Enter the username root and the password default. You should now see the command line prompt which is a hash (#)

The config Tool

Syntax config [ -ahv ] [ -d id ] [ -g id ] [ -p path ] [ -r configurator ] [ -s id=value ]

Description

The config tool allows manipulation and querying of the system configuration from the command line. Using config, the new configuration can be activated by running the relevant configurator which performs the action necessary to make the configuration changes live.

Configuration elements which can be changed are specified by a unique '.' separated name. For example, the configuration file version is identified as 'config.version'.

The config tool is designed to perform multiple actions from one command if needed, so if necessary, options can be chained together.

Page 153 of the Tripp Lite B096-048 user manual — Options
Page 153 · click to enlarge
Page 153

Options

-a –run-all Run all registered configurators. This performs every configuration synchronization action pushing all changes to the live system

-h –help Display a brief usage message.

-v –verbose Log extra debug information

-d –del=id Remove the given configuration element specified by a '.' separated identifier.

-g –get=id Display the value of a configuration element.

-p –path=file Specify an alternate configuration file to use. The default file is located at /etc/config/config.xml

-r –run=configurator Run the specified registered configurator. Registered configurators are

listed below.

-s --set=id=value Change the value of configuration element specified by a '.' separated identifier

-e --export=file Save active configuration to file.

-i --import=file Load configuration from file.

-t --test-import=file Pretend to load configuration from file.

-S --separator=char The pattern to separate fields with, default is '.'. The registered configurators are:

ipconfig nagios power serialconfig services Slave systemsettings time ups users

alerts auth cascade console dhcp dialin eventlog hosts ipaccess

Page 154 of the Tripp Lite B096-048 user manual — Authentication Configuration
Page 154 · click to enlarge
Page 154

14.2 Administration Configuration

System Settings

To change system settings to the following values:

System Name og.mydomain.com

System Password (root account) secret

System SMTP Server 192.168.0.124

System SMTP Sender og@mydomain.com

The following commands must be issued:

# /bin/config –-set=config.system.name=og.mydomain.com

# /bin/config –-set=config.system.password= #secret

# /bin/config –-set=config.system.smtp.server=192.168.0.124

# /bin/config –-set=config.system.smtp.sender=og@mydomain.com

The following command will synchronize the live system with the new configuration:

The Console Server does not store user passwords in plain text so when manually setting the passwords using config -set you need to hash the “secret” and enter the hashed password (#secret). (One easy way to generate a hashed password is to run perl -e 'print crypt("", "")' on a Perl enabled box)

Authentication Configuration

You can configure the system remote authentication with the following settings:

Remote Authentication Method LDAP

Server IP Address 192.168.0.32

LDAP Base Node Some base node

By issuing the following commands:

# /bin/config –-set=config.auth.type=LDAP

# /bin/config –-run=systemsettings · Server Password Secret

Page 155 of the Tripp Lite B096-048 user manual — Network Time Protocol
Page 155 · click to enlarge
Page 155

# /bin/config –-set=config.auth.server=192.168.0.32

# /bin/config –-set=config.auth.password=Secret

# /bin/config –-set=”config.auth.ldap.basenode=some base node”

The following command will synchronize the live system with the new configuration.

14.3 Date and Time Configuration

Manually Change Clock Settings

To change the running system time, you need to issue the following commands:

# date 092216452005.05 Format is MMDDhhmm[[CC]YY][.ss]

Then the following command will save this new system time to the hardware clock:

Alternately, to change the hardware clock time, you need to issue the following commands:

# /bin/hwclock --set --date=092216452005.05

Where the format is MMDDhhmm[[CC]YY][.ss]

Then the following command will save this new hardware clock time as the system time:

Network Time Protocol

To enable NTP using a server at pool.ntp.org, issue the following commands:

# /bin/config –-set=config.ntp.enabled=on

# /bin/config –-set=config.ntp.server=pool.ntp.org

The following command will synchronize the live system with the new configuration.

Show 4 more labels / short text on this page
# /bin/config –-run=auth · # /bin/hwclock –systohc · # /bin/hwclock –hctosys · # /bin/config –-run=time
Page 156 of the Tripp Lite B096-048 user manual — Static
Page 156 · click to enlarge
Page 156

Time Zone

To change the system time zone USA to Eastern Standard Time, you need to issue the following commands:

# /bin/config –-set=config.system.timezone=US/Eastern

The following command will synchronize the live system with the new configuration.

14.4 Network Configuration

IP Configuration

Please note that supported interface modes are 'dhcp' and 'static':

DHCP

To enable a DHCP client on the primary Network interface (eth0) from the Console Server command line:

# /bin/config --set=config.interfaces.wan.mode=dhcp

The following command will then synchronize the live system with the new configuration.

Please note that supported interface modes are 'dhcp' and 'static'.

Static

To set static configuration on the primary Network interface with the following attributes:

IP Address192.168.1.100
Network Mask255.255.255.0
Default Gateway192.168.1.1

# /bin/config –-run=time · # /bin/config –-run=ipconfig

Page 157 of the Tripp Lite B096-048 user manual — Dial-in Configuration
Page 157 · click to enlarge
Page 157
IP Address192.168.1.100
Primary DNS192.168.1.254
Secondary DNS10.1.0.254

You would need to issue the following commands from the command line:

# /bin/config --set=config.interfaces.wan.mode=static # /bin/config --set=config.interfaces.wan.address=192.168.1.100 # /bin/config --set=config.interfaces.wan.netmask=255.255.255.0 # /bin/config --set=config.interfaces.wan.gateway=192.168.1.1 # /bin/config --set=config.interfaces.wan.dns1=192.168.1.254 # /bin/config --set=config.interfaces.wan.dns2=10.1.0.254

The following command will synchronize the live system with the new configuration.

Dial-in Configuration

To enable dial-in access on the DB9 serial port from the command line with the following attributes:

Local IP Address 172.24.1.1

Remote IP Address 172.24.1.2

Authentication TypeMSCHAPv2
Serial Port Baud Rate115200
Serial Port Flow ControlHardware
Custom Modem InitializationATQ0V1H0

You would need to issue the following commands from the command line to set system configuration:

# /bin/config –-set=config.console.ppp.localip=172.24.1.1

# /bin/config –-set=config.console.ppp.remoteip=172.24.1.2

# /bin/config –-set=config.console.ppp.auth=MSCHAPv2

# /bin/config –-set=config.console.ppp.enabled=on

# /bin/config –-set=config.console.speed=115200

# /bin/config –-run=ipconfig

Page 158 of the Tripp Lite B096-048 user manual — Services Configuration
Page 158 · click to enlarge
Page 158

# /bin/config –-set=config.console.flow=Hardware

# /bin/config –-set=config.console.initstring=ATQ0V1H0

The following command will synchronize the live system with the new configuration.

Please note that supported authentication types are 'None', 'PAP', 'CHAP' and 'MSCHAPv2'.

Supported serial port baud-rates are '9600', '19200', '38400', '57600', '115200', and '230400'.

Supported parity values are 'None', 'Odd', 'Even', 'Mark' and 'Space'.

Supported data-bits values are '8', '7', '6' and '5'.

Supported stop-bits values are '1', '1.5' and '2'.

Supported flow-control values are 'Hardware', 'Software' and 'None'.

If you do not wish to use out-of-band dial-in access, please note that the procedure for enabling start-up messages on the console port is covered in Chapter 15: Accessing the Console Port.

Services Configuration

You can manually enable or disable network servers from the command line. For example, if you wanted to guarantee the following server configuration:

Ping Replies (Respond to ICMP echo requests) Disabled

You would need to issue the following commands from the command line to set system configuration:

# /bin/config –-set=config.services.http.enabled=on

# /bin/config –-del=config.services.https.enabled

# /bin/config –-del=config.services.Telnet.enabled

# /bin/config –-set=config.services.ssh.enabled=on

# /bin/config –-del=config.services.snmp.enabled

Show 6 more labels / short text on this page
# /bin/config –-run=dialin · HTTP Server Enabled · HTTPS Server Disabled · Telnet Server Disabled · SSH Server Enabled · SNMP Server Disabled
Page 159 of the Tripp Lite B096-048 user manual — Serial Port Settings
Page 159 · click to enlarge
Page 159

# /bin/config –-del=config.services.pingreply.enabled

The following command will synchronize the live system with the new configuration.

14.5 Serial Port Configuration

Serial Port Settings

To setup serial port 5 to use the following properties:

You would need to issue the following commands from the command line to set the port configuration:

# /bin/config –-set=config.ports.port5.speed=115200

# /bin/config –-set=config.ports.port5.parity=None

# /bin/config –-set=config.ports.port5.charsize=8

# /bin/config –-set=config.ports.port5.stop=1

# /bin/config –-set=config.ports.port5.flow=Software

The following command will synchronize the live system with the new configuration.

Supported data-bits values are '8', '7', '6' and '5'.

Supported stop-bits values are '1', '1.5' and '2'.

Show 7 more labels / short text on this page
# /bin/config –-run=services · Baud Rate 115200 · Parity None · Data Bits 8 · Stop Bits 1 · Flow Control Software · # /bin/config –-run=serialconfig
Page 160 of the Tripp Lite B096-048 user manual — Users
Page 160 · click to enlarge
Page 160

Supported flow-control values are 'Hardware', 'Software' and 'None'.

Supported Protocol Configuration

To ensure remote access to serial port 5 is configured as follows:

Telnet Access LAN Disabled

SSH Access LAN Enabled

Raw TCP via LAN Disabled

You would need to issue the following commands from the command line to set system configuration:

# /bin/config –-set=config.ports.port5.ssh=on

# /bin/config –-del=config.ports.port5.Telnet

# /bin/config –-del=config.ports.port5.tcp

The following command will synchronize the live system with the new configuration.

Users

You can add a User to the system from the command line by performing the following instructions:

Determine the total number of existing Users. If you have no existing Users, you can assume this is 0.

# /bin/config –-get=config.users.total

This command should display:

config.users.total 1

config.users.total

This means you have 0 Users configured.

# /bin/config –-run=serialconfig

Page 161 of the Tripp Lite B096-048 user manual — Trusted Networks
Page 161 · click to enlarge
Page 161

So your new User will be the existing total plus 1, so if the previous command gave you 0, then you start with user number 1. If you already have 1 user, your new user will be number 2, etc.

If you want a user named “user1” with a password of “secret” who will have access to serial port 5 from the network, you need to issue the these commands (assuming you have a previous user in place):

# /bin/config –-set=config.users.user2.username=user1

# /bin/config –-set=config.users.user2.password=secret

# /bin/config –-set=”config.users.user2.description=The Second User”

# /bin/config –-set=config.users.user2.port5=on

# /bin/config –-set=config.users.total=2

The following command will synchronize the live system with the new configuration.

Trusted Networks

You can further restrict remote access to serial ports based on the source IP address. To configure this via the command line, you need to do the following:

Determine the total number of existing trusted network rules. If you have no existing rules, you can assume this is 0.

# /bin/config –-get=config.portaccess.total

This command should display:

config.portaccess.total 1

config.portaccess.total

This means you have 0 rules configured.

Your new rule will be the existing total plus 1. So if the previous command gave you 0, then you start with rule number 1. If you already have 1 rule, your new rule will be number 2, etc.

If you want to restrict access to serial port 5 to computers from a single C class network 192.168.5.0, you need to issue the following commands (assuming you have a previous rule in place):

# /bin/config –-set=config.portaccess.rule2.address=192.168.5.0

# /bin/config –-run=users

Page 162 of the Tripp Lite B096-048 user manual — Remote Serial Port Log Storage
Page 162 · click to enlarge
Page 162

# /bin/config –-set=config.portaccess.rule2.netmask=255.255.255.0

# /bin/config –-set=”config.portaccess.rule2.description=foo bar.”

# /bin/config –-set=config.portaccess.rule2.port5=on

# /bin/config –-set=config.portaccess.total=2

Please note that this rule becomes live straight away.

14.6 Event Logging Configuration

Remote Serial Port Log Storage

To setup remote storage of serial port 5 log to a remote Windows share with the following properties:

IP Address 192.168.0.254

Directory C:\\tripplite\logs\

Logging level 2 (input/output logging as well as user connections & disconnections)

The following commands must be issued:

# /bin/config –-set=config.eventlog.server.type=cifs

# /bin/config –-set=config.eventlog.server.address=192.168.0.254

# /bin/config –-set=config.eventlog.server.path=/tripplite/logs

# /bin/config –-set=config.eventlog.server.username=cifs_user

# /bin/config –-set=config.eventlog.server.password=secret

# /bin/config –-set=config.ports.port5.loglevel=2

The following command will synchronize the live system with the new configuration.

Supported port logging levels are '0', '1' and '2'.

Username cifs_user · Password secret · # /bin/config –-run=eventlog

Page 163 of the Tripp Lite B096-048 user manual — SDT host TCP Ports
Page 163 · click to enlarge
Page 163

Alert Configuration

You can add an email alert to the system from the command line by following these instructions:

Determine the total number of existing alerts (if you have no existing alerts) you can assume this is 0.

# /bin/config –-get=config.alerts.total

This command should display output similar to:

config.alerts.total 1

config.alerts.total

This means you have 0 alerts configured.

Your new alert will be the existing total plus 1. So if the previous command gave you 0, then you start with user number 1. If you already have 1 alert, your new alert will be number 2, etc.

To configure an email alert to be sent to alert1@domain.org when the regular expression “Cpu.*0.0% id,” matches logging on serial port 5, you would need to issue the following commands (Assuming you have 1 previous alert in place):

# /bin/config –-set=config.alerts.alert2.email=alert1@domain.com

# /bin/config –-set=”config.alerts.alert2.pattern=.*0.0% id,”

# /bin/config –-set=config.alerts.alert2.port5=on

# /bin/config –-del=config.alerts.total=2

The following command will synchronize the live system with the new configuration.

14.7 SDT Host Configuration

SDT host TCP Ports

To setup the list of TCP ports for a host, you use the config command:

# config -s config.sdt.hosts.host3.tcpports.tcport1 = 23

# config -s config.sdt.hosts.host3.tcpports.tcport2 = 5900

# /bin/config –-run=alerts

Page 164 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 164 · click to enlarge
Page 164

# config -s config.sdt.hosts.host3.tcpports.tcport3 = 3389

The above assumes the config below:

# vi /etc/config/config.xml ~

accounts.intranet.myco.com

192.168.254.191

Show 21 more labels / short text on this page
</users> · </host1> · <total>3</total> · <host2> · <description>Accounts server</description> · <users> · <total>1</total> · <user1>John</user1> · </users> · </host2> · <host3> · <description>Tonys Win2000 Box</description> · <users> · <total>1</total> · <user1>John</user1> · </users> · <tcpports><tcpport1>23</tcpport1></tcpports> · </host3> · </hosts> · </sdt> · </config>
Page 165 of the Tripp Lite B096-048 user manual — 14.8 Configuration backup and restore
Page 165 · click to enlarge
Page 165

14.8 Configuration backup and restore

Before backing up the configuration, you need to arrange a way to transfer the backup off-box. This could be via an NFS share, a Samba (Windows) share to USB storage, or copied off-box via the network. If backing up directly to off-box storage, make sure it is mounted. /tmp is not a good location for the backup except as a temporary location before transferring it off-box. The /tmp directory will not survive a reboot. The /etc/config directory is not a good place either, as it will not survive a restore. Backup and restore should be done by the root user to ensure correct file permissions are set. The config command is used to create a backup tarball:

config -e <Output File> The tarball will be saved to the indicated location. It will contain the contents of the /etc/config/ directory in an uncompressed and unencrypted form. Example nfs storage:

# mount -t nfs 192.168.0.2:/backups /mnt # config -e /mnt/xxxxx.config # umount/mnt/ Example transfer off-box via scp:

# config -e /tmp/xxxxx.config # scp /tmp/xxxxx.config 192.168.0.2:/backups The config command is also used to restore a backup: config -i <Input File> This will extract the contents of the previously created backup to /tmp, and then synchronize the /etc/config directory with the copy in /tmp. One possible problem that can occur here is that there is not enough room in /tmp to extract files to. The following command will temporarily increase the size of /tmp:

mount -t tmpfs -o remount,size=2048k tmpfs /var If restoring to either a new unit or one that has been factory defaulted, it is important to make sure that the process generating SSH keys is either stopped or completed before restoring configuration. If this is not done, then a mix of old and new keys may be put in place.

Page 166 of the Tripp Lite B096-048 user manual — 14.9 General Linux command usage
Page 166 · click to enlarge
Page 166

As SSH uses these keys to avoid man-in-the-middle attacks, logging in may be disrupted.

14.9 General Linux command usage

The Console Server platform is a dedicated Linux computer, optimized to provide access to serial consoles of critical server systems and control network connected hosts. Being based around uClinux (a small footprint but extensible Linux), it embodies a myriad of popular and proven Linux software modules for networking (NetFilter, IPTables), secure access (OpenSSH) and communications (OpenSSL) and sophisticated user authentication (PAM, RADIUS, TACACS+ and LDAP).

Many components of the Console Server software are licensed under the GNU General Public License (version 2). You may obtain a copy of the GNU General Public License at http://www.fsf.org/copyleft/gpl.html and source code will provided for any of the components of the Software licensed under the GNU General Public License upon request. The Console Servers are built on the 2.4 uClinux kernel as developed by the uClinux project. This is GPL code and source can be found: http://cvs.uclinux.org

Supported commands that have config files that can be altered include:

portmanager inetd init ssh/sshd/scp/sshkeygen ucd-snmpd http://www.ece.ucdavis.edu/ucd-snmp/ samba fnord (web server) sslwrap Commands you can run from the command line on the Console Server include:: loopback bash (shell) busybox http://www.busybox.net/downloads/BusyBox.html (has lots of unix shell commands and tools) chat dhcpcd ftp hd hwclock iproute iptables netcat ifconfig mii-tool netstat

Page 167 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 167 · click to enlarge
Page 167

route openntpd ping portmap pppd routed setserial smtpclient stty stunel tcpdump tftp tip traceroute More details on the above Linux commands can found online at:

http://en.tldp.org/HOWTO/HOWTO-INDEX/howtos.html

http://www.faqs.org/docs/Linux-HOWTO/Remote-Serial-Console-HOWTO.html

http://www.stokely.com/unix.serial.port.resources/serial.switch.html

Page 168 of the Tripp Lite B096-048 user manual — Introduction
Page 168 · click to enlarge
Page 168

15. ADVANCED CONFIGURATION

Introduction

This chapter documents the embedded portmanager application which manages the serial ports on the Console Server and gives examples of its use:

ƒ Scripts and alerts

ƒ Raw data access to the ports and modems

This chapter also describes details how to perform advanced and custom management tasks using Linux commands and script:

ƒ iptables modifications and updating IP Filtering rules

ƒ modifying SNMP with net-snmpd

ƒ public key authenticated SSH communications

ƒ SSL, configuring HTTPS and issuing certificates

ƒ using the pmpower application and powerman for power device management

ƒ using IPMI tools

ƒ portmanager documentation

Page 169 of the Tripp Lite B096-048 user manual — 15.1 Advanced Portmanager
Page 169 · click to enlarge
Page 169

15.1 Advanced Portmanager

pmshell

The pmshell command acts similarly to the standard tip or cu commands, but all serial port access is directed via the portmanager.

Example:

To connect to port 8 via the portmanager:

# pmshell -l port08

pmshell Commands:

Once connected, the pmshell command supports a subset of the '~' escape commands that tip/cu support. For SSH, you must prefix the escape with an additional ‘~’ command (i.e. use the ‘~~’ escape)

Send Break:

Typing the character sequence '~b' will generate a BREAK on the serial port.

History:

Typing the character sequence '~h' will generate a history on the serial port.

Quit pmshell:

Typing the character sequence '~.' will exit from pmshell.

Set RTS to 1 run the command:

# pmshell –signals DSR=1 DTR=1 CTS=1 RTS=1 DCD=0

Read a line of text from the serial port:

# pmshell --rts=1 · Show all signa · # pmshell –getline

Page 170 of the Tripp Lite B096-048 user manual — pmchat
Page 170 · click to enlarge
Page 170

pmchat

The pmchat command acts similarly to the standard chat command, but all serial port access is directed via the portmanager.

Example:

To run a chat script via the portmanager:

# pmchat -v -f /etc/config/scripts/port08.chat < /dev/port08 For more information on using chat (and pmchat), you should consult the UNIX man pages: http://techpubs.sgi.com/library/tpl/cgi- bin/getdoc.cgi?coll=linux&db=man&fname=/usr/share/catman/man8/chat.8.html

pmusers The pmusers command is used to query the portmanager for active user sessions. Example:

To detect which users are currently active on which serial ports: # pmusers This command will not output anything if there are no active users currently connected to any ports, otherwise, it will respond with a sorted list of usernames per active port: Port 1: user1 user2 Port 2: user1 Port 8: user2 The above output indicates that a user named “user1” is actively connected to ports 1 and 2, while “user2” is connected to both ports 1 and 8.

Page 171 of the Tripp Lite B096-048 user manual — 15.2 External Scripts and Alerts
Page 171 · click to enlarge
Page 171

Portmanager Daemon

There is normally no need to stop and restart the daemon. To restart the daemon, just run the command:

Supported command line options are:

Force portmanager to run in the foreground:

Set the level of debug logging:

Change which configuration file it uses:

-c /etc/config/portmanager.conf

Signals

Sending a SIGHUP signal to the portmanager will cause it to reread its configuration file

15.2 External Scripts and Alerts

The portmanager has the ability to execute external scripts on certain events. These events are:

I. When a port is opened by the portmanager:

When the portmanager opens a port, it attempts to execute /etc/config/scripts/portXX.init (where XX is the number of the port, e.g. 08). The script is run with STDIN and STDOUT both connected to the serial port.

If the script cannot be executed, then portmanager will execute /etc/config/scripts/portXX.chat via the chat command on the serial port.

II. When an alert occurs on a port:

Show 4 more labels / short text on this page
Command line options · # portmanager · --nodaemon · --loglevel={debug,info,warn,error,alert}
Page 172 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 172 · click to enlarge
Page 172

When an alert occurs on a port, the portmanager will attempt to execute /etc/config/scripts/portXX.alert (where XX is the port number, e.g. 08)

The script is run with STDIN containing the data which triggered the alert, and STDOUT redirected to /dev/null, NOT to the serial port. If you wish to communicate with the port, use pmshell or pmchat from within the script.

If the script cannot be executed, then the alert will be mailed to the address configured in the system administration section.

III. When a user connects to any port:

If a file called /etc/config/pmshell-start.sh exists, it is run when a user connects to a port. It is provided with 2 arguments, the "Port number" and the "Username". Here is a simple example: </etc/config/pmshell-start.sh > #!/bin/sh PORT="$1" USER="$2" echo "Welcome to port $PORT $USER" < /etc/config/pmshell-start.sh> The return value from the script controls whether the user is accepted or not. If 0 is returned (or nothing is done on exit as in the above script), then the user is permitted, otherwise, the user is denied access. Here is a more complex script which reads from configuration to display the port label if available and denies access to the root user: </etc/config/pmshell-start.sh> #!/bin/sh PORT="$1" USER="$2" LABEL=$(config -g config.ports.port$PORT.label | cut -f2- -d' ') if [ "$USER" == "root" ]; then echo "Permission denied for Super User" exit 1

Page 173 of the Tripp Lite B096-048 user manual — Accessing the Console Port
Page 173 · click to enlarge
Page 173

fi if [ -z "$LABEL" ]; then echo "Welcome $USER, you are connected to Port $PORT" else echo "Welcome $USER, you are connected to Port $PORT ($LABEL)" fi </etc/config/pmshell-start.sh>

15.3 Raw Access to Serial Ports

Access to Serial Ports

You can tip and stty to completely bypass the portmanager and have raw access to the serial ports.

When you run tip on a portmanager controlled port, portmanager closes that port, and stops monitoring it until tip releases control of it. With stty, the changes made to the port only "stick" until that port is closed and opened again, so it is doubtful that people will want to use stty for more than initial debugging of the serial connection. If you want to use stty to configure the port, you can put stty commands in /etc/config/scripts/portXX.init, which gets run whenever portmanager opens the port. Otherwise, any setup you do with stty will get lost when the portmanager opens the port. The reason that portmanager sets things back to its config, rather than using whatever is on the port, is so the port is in a known good state, and will work, no matter what things are done to the serial port outside of portmanager.

Accessing the Console Port

The console dial-in is handled by mgetty, with automatic PPP login extensions. mgetty is a smart getty replacement, designed to be used with hayes compatible data and data/fax modems. mgetty knows about modem initialization, manual modem answering (so your modem doesn’t answer if the machine isn’t ready), UUCP locking (so you can use the same device for dial-in and dial-out). mgetty provides very extensive logging facilities. All standard mgetty options are supported. ƒ Modem initialization strings

Page 174 of the Tripp Lite B096-048 user manual — /etc/config/ipfilter
Page 174 · click to enlarge
Page 174

To override the standard modem initialization string, either use the Management Console (refer to Chapter 5) or the command line config tool (refer to Dial-In Configuration Chapter 14). ƒ Enabling Boot Messages on the Console

If you are not using a modem on the DB9 console port and instead wish to connect to it directly via a Null Modem cable, you may want to enable verbose mode, allowing you to see the standard linux start-up messages. This can be achieved with the following commands: # /bin/config --set=config.console.debug=on # /bin/config --run=console # reboot If at some point in the future you chose to connect a modem for dial-in out-of-band access, the procedure can be reversed with the following commands. # /bin/config --del=config.console.debug # /bin/config --run=console # reboot 15.4 IP- Filtering

Standard IP-Filter configuration:

The system uses the iptables utility to provide a stateful firewall of LAN traffic. By default, rules are automatically inserted to allow access to enabled services, and serial port access via enabled protocols. The commands which add these rules are contained in configuration files.

/etc/config/ipfilter

This is an executable shell script which is run whenever the LAN interface is brought up and whenever modifications are made to the iptables configuration as a result of CGI actions or the config command line tool.

The basic steps performed are as follows:

a) The current iptables configuration is erased.

b) If a customized IP-Filter script exists, it is executed and no other actions are performed.

c) Standard policies are inserted which will drop all traffic not explicitly allowed to and

through the system.

d) Rules are added which explicitly allow network traffic to access enabled services e.g.

HTTP, SNMP etc.

e) Rules are added which explicitly allow traffic network traffic access to serial ports over

enabled protocols e.g. Telnet, SSH and raw TCP.

Page 175 of the Tripp Lite B096-048 user manual — Customizing the IP-Filter:
Page 175 · click to enlarge
Page 175

Customizing the IP-Filter:

/ etc/config/filter-custom

If the standard system firewall configuration is not adequate for your needs, it can be bypassed safely by creating a file at /etc/config/filter, custom- containing commands to build a specialized firewall. This firewall script will be run whenever the LAN interface is brought up (including initially) and will override any automated system firewall settings.

Below is a simple example of a custom script which creates a firewall using the iptables command. Only incoming connections from computers on a C-class network 192.168.10.0 will be accepted when this script is installed at /etc/config/filter-custom (Note that when this script is called, any preexisting chains and rules have been flushed from iptables):

# Set default policies to drop any incoming or routable traffic

# and blindly accept anything from the 192.168.10.0 network.

iptables –-policy FORWARD DROP

iptables –-policy INPUT DROP

iptables –-policy OUTPUT ACCEPT

# Allow responses to outbound connections back in.

iptables –-append INPUT \

–-match state –-state ESTABLISHED,RELATED –-jump ACCEPT

# Explicitly accept any connections from computers on

# 192.168.10.0/24

iptables –-append INPUT –-source 192.168.10.0/24 –-jump ACCEPT

Good documentation about using the iptables command can be found at the linux netfilter website http://netfilter.org/documentation/index.html

#/bin/sh

Page 176 of the Tripp Lite B096-048 user manual — 15.5 Modifying SNMP Configuration
Page 176 · click to enlarge
Page 176

Resources

There are many high-quality tutorials and HOWTOs available via the netfilter website; in particular, peruse the tutorials listed on the netfilter HOWTO page. A list of useful web locations has been compiled for your convenience below:

Netfilter Homepage http://netfilter.org

Netfilter/iptables Tutorials http://netfilter.org/documentation/index.html#documentation- tutorials

15.5 Modifying SNMP Configuration

/etc/config/snmpd.conf

The net-snmpd is an extensible SNMP agent which responds to SNMP queries for management information from SNMP management software. Upon receiving a request, it processes the request(s), collects the requested information and/or performs the requested operation(s) and returns the information to the sender.

This includes built-in support for a wide range of MIB information modules, and can be extended using dynamically loaded modules, external scripts and commands. Snmpd, when enabled, should run with a default configuration. Its behavior can be customized via the options in /etc/config/snmpd.conf.

Changing standard system information such as system contact, name and location can be achieved by editing /etc/config/snmpd.conf file and locating the following lines:

syscontact root <root@localhost>(configure /etc/default/snmpd.conf)

sysname Not defined (edit /etc/default/snmpd.conf)

syslocation Not defined (edit /etc/default/snmpd.conf)

Simply change the values of sysdescr, syscontact, sysname and syslocation to the desired settings and restart snmpd.

sysdescr "tripplite"

Page 177 of the Tripp Lite B096-048 user manual — Adding more than one SNMP server
Page 177 · click to enlarge
Page 177

The snmpd.conf is extremely powerful and too flexible to cover completely here. The configuration file itself is commented extensively and good documentation is available at the net-snmp website http://www.net-snmp.org specifically:

Man Pagehttp://www.net-snmp.org/docs/man/snmpd.conf.html
FAQhttp://www.net-snmp.org/docs/FAQ.html
Net-SNMPD Tutorialhttp://www.net-snmp.org/tutorial/tutorial-5/demon/snmpd.html

Adding more than one SNMP server

To add more than one SNMP server for alert traps, add the first SNMP server using the Management Console (refer to Chapter 7) or the command line config tool. Secondary and any further SNMP servers are added manually using config. Log in to the Console Server’s command line shell as root or an admin user. Refer back to the Management Console UI or user documentation for descriptions of each field. To set the Manager Protocol field: config --set config.system.snmp.protocol2=UDP or config --set config.system.snmp.protocol2=TCP To set the Manager Address field config --set config.system.snmp.address2=w.x.y.z .. replacing w.x.y.z with the IP address or DNS name. To set the Manager Trap Port field config --set config.system.snmp.trapport2=162.. replacing 162 with the TCP/UDP port number To set the Version field config --set config.system.snmp.version2=1 or config --set config.system.snmp.version2=2c or config --set config.system.snmp.version2=3 To set the Community field (SNMP version 1 and 2c only) config --set config.system.snmp.community2=yourcommunityname .. replacing yourcommunityname with the community name

Page 178 of the Tripp Lite B096-048 user manual — SSH Overview
Page 178 · click to enlarge
Page 178

To set the Engine ID field (SNMP version 3 only) config --set config.system.snmp.engineid2=800000020109840301 .. replacing 800000020109840301 with the engine ID To set the Username field (SNMP version 3 only) config --set config.system.snmp.username2=yourusername .. replacing yourusername with the username config.system.snmp.username2 (3 only) To set the Engine ID field (SNMP version 3 only) config --set config.system.snmp.password2=yourpassword .. replacing yourpassword with the password Once the fields are set, apply the configuration with the following command: config --run snmp You can add a third or more SNMP servers by incrementing the "2" in the above commands, e.g. config.system.snmp.protocol3, config.system.snmp.address3, etc.

15.6 Secure Shell (SSH) Public Key Authentication

This section covers the generation of public and private keys in a Linux and Windows environment and configuring SSH for public key authentication. The steps to use in a Clustering environment are:

- Generate a new public and private key pair - Upload the keys to the Master and to each Slave Console Server - Fingerprint each connection to validate

SSH Overview

Popular TCP/IP applications such as Telnet, rlogin, ftp, and others transmit their passwords unencrypted. Doing this across public networks like the Internet can have catastrophic consequences. It leaves the door open for eavesdropping, connection hijacking, and other network-level attacks. Secure Shell (SSH) is a program to log into another computer over a network, to execute commands in a remote machine, and to move files from one machine to another. It provides strong authentication and secure communications over unsecure channels.

Page 179 of the Tripp Lite B096-048 user manual — Generating Public Keys (Linux)
Page 179 · click to enlarge
Page 179

OpenSSH, the de facto open source SSH application, encrypts all traffic (including passwords) to effectively eliminate these risks. Additionally, OpenSSH provides a myriad of secure tunneling capabilities, as well as a variety of authentication methods. OpenSSH is the port of OpenBSD's excellent OpenSSH[0] to Linux and other versions of Unix. OpenSSH is based on the last free version of Tatu Ylonen's sample implementation with all patent-encumbered algorithms removed (to external libraries), all known security bugs fixed, new features reintroduced and many other clean-ups. http://www.openssh.com/ The only changes in the SSH implementation are:

ƒ PAM support ƒ EGD[1]/PRNGD[2] support and replacements for OpenBSD library functions that are

absent from other versions of UNIX ƒ The config files are now in /etc/config. e.g.

o /etc/config/sshd_config instead of /etc/sshd_config o /etc/config/ssh_config instead of /etc/ssh_config o /etc/config/users/<username>/.ssh/ instead of /home/<username>/.ssh/

Generating Public Keys (Linux)

To generate new SSH key pairs, use the Linux ssh-keygen command. This will produce an RSA or DSA public/private key pair and you will be prompted for a path to store the two key files e.g. id_dsa.pub (the public key) and id_dsa (the private key). For example:

$ ssh-keygen -t [rsa|dsa] Generating public/private [rsa|dsa] key pair. Enter file in which to save the key (/home/user/.ssh/id_[rsa|dsa]): Enter passphrase (empty for no passphrase): Enter same passphrase again: Your identification has been saved in /home/user/.ssh/id_[rsa|dsa]. Your public key has been saved in /home/user/.ssh/id_[rsa|dsa].pub. The key fingerprint is: 28:aa:29:38:ba:40:f4:11:5e:3f:d4:fa:e5:36:14:d6 user@server $ It is advisable to create a new directory to store your generated keys. It is also possible to name the files after the device they will be used for. For example: $ mkdir keys $ ssh-keygen -t rsa

Page 180 of the Tripp Lite B096-048 user manual — Installing SSH Public Key Authentication (Linux)
Page 180 · click to enlarge
Page 180

Generating public/private rsa key pair. Enter file in which to save the key (/home/user/.ssh/id_rsa): /home/user/keys/control_room Enter passphrase (empty for no passphrase): Enter same passphrase again: Your identification has been saved in /home/user/keys/control_room Your public key has been saved in /home/user/keys/control_room.pub. The key fingerprint is: 28:aa:29:38:ba:40:f4:11:5e:3f:d4:fa:e5:36:14:d6 user@server $ You must ensure there is no password associated with the keys. If there is a password, then the devices will have no way to supply it as runtime. Full documentation for the ssh-keygen command can be found at:

http://www.openbsd.org/cgi-bin/man.cgi?query=ssh-keygen

Installing the SSH Public/Private Keys (Clustering)

For Console Servers, the keys can be simply uploaded through the web interface on the System: Administration page. This enables you to upload stored RSA or DSA Public Key pairs to the Master and apply the Authorized key to the Slave as is described in Chapter 4.6. Once complete, proceed to Fingerprinting as described below.

Tripp Lite B096-048 — Installing the SSH Public/Private Keys (Clustering) diagram (page 180)
Fig. 167 · Installing the SSH Public/Private Keys (Clustering)

Installing SSH Public Key Authentication (Linux)

Alternately, the public key can be installed on the unit remotely from the Linux host with the scp utility as follows:

Page 181 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 181 · click to enlarge
Page 181

Assuming the user on the Management Console is called "fred"; the IP address of the Console Server is 192.168.0.1 (default); and the public key is on the linux/unix computer in ~/.ssh/id_dsa.pub. Execute the following command on the linux/unix computer: scp ~/.ssh/id_dsa.pub \ [email protected]:/etc/config/users/fred/.ssh/authorized_keys The authorized_keys file on the Console Server needs to be owned by "fred", so login to the Management Console as root and type: chown fred /etc/config/users/fred/.ssh/authorized_keys

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 181)
Fig. 168
Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 181)
Fig. 169

If the Console Server device selected to be the server will only have one client device, then the authorized_keys file is simply a copy of the public key for that device. If one or more devices will be clients of the server, then the authorized_keys file will contain a copy of all of the public keys. RSA and DSA keys may be freely mixed in the authorized_keys file. For example, assume we already have one server, called bridge_server, and two sets of keys, for the control_room and the plant_entrance: $ ls /home/user/keys control_room control_room.pub plant_entrance plant_entrance.pub $ cat /home/user/keys/control_room.pub /home/user/keys/plant_entrance.pub > /home/user/keys/authorized_keys_bridge_server

Page 182 of the Tripp Lite B096-048 user manual — Generating public/private keys for SSH (Windows)
Page 182 · click to enlarge
Page 182
Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 182)
Fig. 170
Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 182)
Fig. 171
Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 182)
Fig. 172
Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 182)
Fig. 173
Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 182)
Fig. 174
Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 182)
Fig. 175

More documentation on OpenSSH can be found at:

http://openssh.org/portable.html http://www.openbsd.org/cgi-bin/man.cgi?query=ssh&sektion=1 http://www.openbsd.org/cgi-bin/man.cgi?query=sshd

Generating public/private keys for SSH (Windows)

This section describes how to generate and configure SSH keys using Windows. First create a new user from the Management Console on the Console Server (the following example users a user called "testuser") making sure it is a member of the "users" group. If you do not already have a public/private key pair you can generate them now using ssh- keygen, PuTTYgen or a similar tool: PuTTYgen:

http://www.chiark.greenend.org.uk/~sgtatham/putty/download.html

Page 183 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 183 · click to enlarge
Page 183

OpenSSH:

http://www.openssh.org/ OpenSSH (Windows):

http://sshwindows.sourceforge.net/download/ For example, using PuTTYgen, make sure you have a recent version of the puttygen.exe (available from http://www.chiark.greenend.org.uk/~sgtatham/putty/download.html). Make sure you have a recent version of WinSCP (available from http://winscp.net/eng/download.php) To generate a SSH key using PuTTY http://sourceforge.net/docs/F02/#clients ƒ Execute the PUTTYGEN.EXE program ƒ Select the desired key type SSH2 DSA (you may use RSA or DSA) within the Parameters section ƒ It is important that you leave the passphrase field blank ƒ Click on the Generate button ƒ Follow the instruction to move the mouse over the blank area of the program in order to create random data used by PUTTYGEN to generate secure keys. Key generation will occur once PUTTYGEN has collected sufficient random data .

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 183)
Fig. 176
Page 184 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 184 · click to enlarge
Page 184

ƒ Create a new file " authorized_keys " (with notepad) and copy your public key data from the "Public key for pasting into OpenSSH authorized_keys file" section of the PuTTY Key Generator, and paste the key data to the "authorized_keys" file. Make sure there is only one line of text in this file. ƒ Use WinSCP to copy this "authorized_keys" file into the users home directory: eg. /etc/config/users/testuser/.ssh/authorized_keys of the Console Server which will be the SSH server. You will need to make sure this file is in the correct format with the correct permissions with the following commands:

# dos2unix \ /etc/config/users/testuser/.ssh/authorized_keys && chown testuser \ /etc/config/users/testuser/.ssh/authorized_keys

ƒ Using WinSCP copy the attached sshd_config over /etc/config/sshd_config on the server (Makes sure public key authentication is enabled) ƒ Test the Public Key by logging in as "testuser". Test the Public Key by logging in as "testuser" to the client device and typing (you should not need to enter anything): # ssh - o StrictHostKeyChecking=no To automate connection of the SSH tunnel from the client on every power-up, you need to make the clients /etc/config/rc.local look like the following: #!/bin/sh ssh -L9001:127.0.0.1:4001 -N -o StrictHostKeyChecking=no testuser@<server-ip> & This will run the tunnel redirecting local port 9001 to the server port 4001. Fingerprinting

Fingerprints are used to ensure you are establishing an SSH session to who you think you are. On the first connection to a remote server, you will receive a fingerprint which you can use on future connections. This fingerprint is related to the host key of the remote server. Fingerprints are stored in ~/.ssh/known_hosts. To receive the fingerprint from the remote server, log in to the client as the required user (usually root) and establish a connection to the remote host: # ssh remhost

Page 185 of the Tripp Lite B096-048 user manual — SSH tunneled serial bridging
Page 185 · click to enlarge
Page 185

The authenticity of host 'remhost (192.168.0.1)' can't be established. RSA key fingerprint is 8d:11:e0:7e:8a:6f:ad:f1:94:0f:93:fc:7c:e6:ef:56. Are you sure you want to continue connecting (yes/no)? At this stage, answer yes to accept the key. You should get the following message:

@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@ @ WARNING: REMOTE HOST IDENTIFICATION HAS CHANGED! @ @ IT IS POSSIBLE THAT SOMEONE IS DOING SOMETHING NASTY! @ @@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@ Someone could be eavesdropping on you right now (man-in-the-middle attack)! It is also possible that the RSA host key has just been changed. The fingerprint for the RSA key sent by the remote host is ab:7e:33:bd:85:50:5a:43:0b:e0:bd:43:3f:1c:a5:f8. Please contact your system administrator. Add correct host key in /.ssh/known_hosts to get rid of this message. Offending key in /.ssh/known_hosts:1 RSA host key for remhost has changed and you have requested strict checking. Host key verification failed. If the host key has been legitimately changed, it can be removed from the ~/.ssh/known_hosts file and the new fingerprint added. If it has not changed, this indicates a serious problem that should be investigated immediately.

SSH tunneled serial bridging

You have the option to apply SSH tunneling when two Console Servers are configured for serial bridging.

Page 186 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 186 · click to enlarge
Page 186

As detailed in Chapter 4, the Server gateway is set up in Console Server mode with either RAW or RFC2217 enabled and the Client gateway is set up in Serial Bridging Mode with the Server Address, and Server TCP Port (4000 + port for RAW or 5000 + port # for RFC2217) specified: ¾ Select SSH Tunnel when configuring the Serial Bridging Setting

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 186)
Fig. 177

Next you will need to set up SSH keys for each end of the tunnel and upload these keys to the Server and Client gateways. Client Keys The first step in setting up SSH tunnels is to generate keys. Ideally, you will use a separate, secure machine to generate and store all keys to be used on the devices. However, if this is not ideal to your situation, keys may be generated on the Console Servers themselves. It is possible to generate only one set of keys, and reuse them for every SSH session. While this is not recommended, each organization will need to balance the security of separate keys against the additional administration they bring.

Page 187 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 187 · click to enlarge
Page 187

Generated keys may be one of two types - RSA or DSA (and it is beyond the scope of this document to recommend one over the other). RSA keys will go into the files id_rsa and id_rsa.pub. DSA keys will be stored in the files id_dsa and id_dsa.pub. For simplicity going forward, the term private key will be used to refer to either id_rsa or id_dsa and public key to refer to either id_rsa.pub or id_dsa.pub.

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 187)
Fig. 178

To generate the keys using OpenBSD's OpenSSH suite, we use the ssh-keygen program:

$ ssh-keygen -t [rsa|dsa] Generating public/private [rsa|dsa] key pair. Enter file in which to save the key (/home/user/.ssh/id_[rsa|dsa]): Enter passphrase (empty for no passphrase): Enter same passphrase again: Your identification has been saved in /home/user/.ssh/id_[rsa|dsa]. Your public key has been saved in /home/user/.ssh/id_[rsa|dsa].pub. The key fingerprint is: 28:aa:29:38:ba:40:f4:11:5e:3f:d4:fa:e5:36:14:d6 user@server $ It is advisable to create a new directory to store your generated keys. It is also possible to name the files after the device they will be used for. For example: $ mkdir keys $ ssh-keygen -t rsa Generating public/private rsa key pair. Enter file in which to save the key (/home/user/.ssh/id_rsa): /home/user/keys/control_room Enter passphrase (empty for no passphrase): Enter same passphrase again:

Page 188 of the Tripp Lite B096-048 user manual — SDT Connector Public Key Authentication
Page 188 · click to enlarge
Page 188

Your identification has been saved in /home/user/keys/control_room Your public key has been saved in /home/user/keys/control_room.pub. The key fingerprint is: 28:aa:29:38:ba:40:f4:11:5e:3f:d4:fa:e5:36:14:d6 user@server $ You should ensure there is no password associated with the keys. If there is a password, then the Console Server devices will have no way to supply it as runtime. Authorized Keys If the Console Server device selected to be the server will only have one client device, then the authorized_keys file is simply a copy of the public key for that device. If one or more devices will be clients of the server, then the authorized_keys file will contain a copy of all of the public keys. RSA and DSA keys may be freely mixed in the authorized_keys file. For example, assume we already have one server, called bridge_server, and two sets of keys, for the control_room and the plant_entrance: $ ls /home/user/keys control_room control_room.pub plant_entrance plant_entrance.pub $ cat /home/user/keys/control_room.pub /home/user/keys/plant_entrance.pub > /home/user/keys/authorized_keys_bridge_server Uploading Keys The keys for the server can be uploaded through the web interface, on the System: Administration page as detailed earlier. If only one client will be connecting, then simply upload the appropriate public key as the authorized keys file. Otherwise, upload the authorized keys file constructed in the previous step. Each client will then need its own set of keys uploaded through the same page. Take care to ensure that the correct type of keys (DSA or RSA) go in the correct spots, and that the public and private keys are in the correct spot.

SDT Connector Public Key Authentication

SDT Connector can authenticate against a Console Server using your SSH key pair rather than requiring your to enter your password (i.e. public key authentication).

Page 189 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 189 · click to enlarge
Page 189

¾ To use public key authentication with SDT Connector, first you must first create an RSA or

DSA key pair (using ssh-keygen, PuTTYgen or a similar tool) and add the public part of your SSH key pair to the Console Server – as described in the earlier section. ¾ Next, add the private part of your SSH key pair (this file is typically named id_rsa or id_dsa)

to SDT Connector client. Click Edit -> Preferences -> Private Keys -> Add, locate the private key file and click OK. You do not have to add the public part of your SSH key pair, it is calculated using the private key. SDT Connector will now use public key authentication when SSH connecting through the Console Server. You may have to restart SDT Connector to shut down any existing tunnels that were established using password authentication. If you have a host behind the Console Server that you connect to by clicking the SSH button in SDT Connector, you can also configure it for public key authentication. Essentially, what you are using is SSH over SSH, and the two SSH connections are entirely separate, and the host configuration is entirely independent of SDT Connector and the Console Server. You must configure the SSH client that SDT Connector launches (e.g. Putty, OpenSSH) and the host's SSH server for public key authentication. 15.7 Secure Sockets Layer (SSL) Support

Secure Sockets Layer (SSL) is a protocol developed by Netscape for transmitting private documents via the Internet. SSL works by using a private key to encrypt data that's transferred over the SSL connection. The Console Server includes OpenSSL. The OpenSSL Project is a collaborative effort to develop a robust, commercial-grade, full-featured, and Open Source toolkit implementing the Secure Sockets Layer (SSL v2/v3) and Transport Layer Security (TLS v1) protocols as well as a full- strength general purpose cryptography library. The project is managed by a worldwide community of volunteers that use the Internet to communicate, plan, and develop the OpenSSL toolkit and its related documentation.

OpenSSL is based on the excellent SSLeay library developed by Eric A. Young and Tim J. Hudson. The OpenSSL toolkit is licensed under an Apache-style license, which basically means that you are free to get and use it for commercial and non-commercial purposes, subject to some simple license conditions. In the Console Server, OpenSSL is used primarily in conjunction with ‘http’ in order to have secure browser access to the GUI management console across insecure networks.

More documentation on OpenSSL is available from:

Page 190 of the Tripp Lite B096-048 user manual — 15.8 HTTPS
Page 190 · click to enlarge
Page 190

http://www.openssl.org/docs/apps/openssl.html http://www.openssl.org/docs/HOWTO/certificates.txt

15.8 HTTPS

The Management Console can be served using HTTPS by running the webserver via sslwrap. The server can be launched on request using inetd. The HTTP server provided is a slightly modified version of the fnord-httpd from http://www.fefe.de/fnord/ The SSL implementation is provided by the sslwrap application compiled with OpenSSL support. More detailed documentation can be found at http://www.rickk.com/sslwrap/ If your default network address is changed or the unit is to be accessed via a known Domain Name, you can use the following steps to replace the default SSL Certificate and Private Key with ones tailored for your new address. 1. Generating an encryption key To create a 1024 bit RSA key with a password, issue the following command on the command line of a Linux host with the openssl utility installed: openssl genrsa -des3 -out ssl_key.pem 1024 2. Generating a self-signed certificate with OpenSSL This example shows how to use OpenSSL to create a self-signed certificate. OpenSSL is available for most Linux distributions via the default package management mechanism. (Windows users can check http://www.openssl.org/related/binaries.html ) To create a 1024 bit RSA key and a self-signed certificate, send the following openssl command from the host you have openssl installed on: openssl req -x509 -nodes -days 1000 \ -newkey rsa:1024 -keyout ssl_key.pem -out ssl_cert.pem

Page 191 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 191 · click to enlarge
Page 191

You will be prompted to enter a lot of information. Most of it doesn't matter, but the "Common Name" should be the domain name of your computer (e.g. test.tripplite.com). When you have entered everything, the certificate will be created in a file called ssl_cert.pem. 3. Installing the key and certificate The recommended method for copying files securely to the Console Server unit is with an SCP (Secure Copying Protocol) client. The scp utility is distributed with OpenSSH for most Unices, while Windows users can use something like the PSCP command line utility available with PuTTY. The files created in steps 1 and 2 can be installed remotely with the scp utility as follows: scp ssl_key.pem root@<address of unit>:/etc/config/ scp ssl_cert.pem root@<address of unit>:/etc/config/ or using PSCP: pscp -scp ssl_key.pem root@<address of unit>:/etc/config/ pscp -scp ssl_cert.pem root@<address of unit>:/etc/config/ PuTTY and the PSCP utility can be downloaded from http://www.chiark.greenend.org.uk/~sgtatham/putty/download.html More detailed documentation on the PSCP can be found: http://the.earth.li/~sgtatham/putty/0.58/htmldoc/Chapter5.html#pscp 4. Launching the HTTPS Server Note that the easiest way to enable the HTTPS server is from the Management Console. Simply click the appropriate checkbox in Network -> Services -> HTTPS Server and the HTTPS server will be activated (assuming the ssl_key.pem & ssl_cert.pem files exist in the /etc/config directory). Alternatively, inetd can be configured to launch the secure fnord server from the command line of the unit as follows. Edit the inetd configuration file. From the unit command line: vi /etc/config/inetd.conf Append a line:

Page 192 of the Tripp Lite B096-048 user manual — PowerMan
Page 192 · click to enlarge
Page 192

443 stream tcp nowait root sslwrap -cert /etc/config/ssl_cert.pem -key /etc/config/ssl_key.pem -exec /bin/httpd /home/httpd" Save the file and signal inetd of the configuration change. kill -HUP `cat /var/run/inetd.pid` The HTTPS server should be accessible from a web client at a URL similar to this: https://<common name of unit> More detailed documentation about the openssl utility can be found at the website: http://www.openssl.org/ 15.9 Power Strip Control

The Console Server supports a growing list of remote power-control devices (RPCs) which can be configured using the Management Console as described in Chapter 8. These RPCs are controlled using the open source NUT and PowerMan tools and the pmpower utility.

PowerMan

PowerMan provides power management in a data center or compute cluster environment. It performs operations such as power on, power off, and power cycle via remote power controller (RPC) devices. Target hostnames are mapped to plugs on RPC devices in powerman.conf powerman - power on/off nodes Synopsis powerman [-option] [targets] pm [-option] [targets] Options -1, --on Power ON targets. -0, --off Power OFF targets. -c, --cycle Power cycle targets. -r, --reset Assert hardware reset for targets (if implemented by RPC). -f, --flash Turn beacon ON for targets (if implemented by RPC). -u, --unflash Turn beacon OFF for targets (if implemented by RPC). -l, --list List available targets. If possible, output will be compressed into a host range (see TARGET SPECIFICATION below). -q, --query Query plug status of targets. If none specified, query all targets. Status is not cached; each time this option is used, powermand queries the appropriate RPC's.

Page 193 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 193 · click to enlarge
Page 193

Targets connected to RPC's that could not be contacted (e.g. due to network failure) are reported as status "unknown". If possible, output will be compressed into host ranges. -n, --node Query node power status of targets (if implemented by RPC). If no targets are specified, query all targets. In this context, a node in the OFF state could be ON at the plug but operating in standby power mode. -b, --beacon Query beacon status (if implemented by RPC). If no targets are specified, query all targets. -t, --temp Query node temperature (if implemented by RPC). If no targets are specified, query all targets. Temperature information is not interpreted by powerman and is reported as received from the RPC on one line per target, prefixed by target name. -h, --help Display option summary. -L, --license Show powerman license information. -d, --destination host[:port] Connect to a powerman daemon on non-default host and optionally

port. -V, --version Display the powerman version number and exit. -D, --device Displays RPC status information. If targets are specified, only RPC's matching the target list are displayed. -T, --telemetry Causes RPC telemetry information to be displayed as commands are processed.

Useful for debugging device scripts. -x, --exprange Expand host ranges in query responses. For more details refer http://linux.die.net/man/1/powerman. Also refer powermand (http://linux.die.net/man/1/powermand) documentation and powerman.conf (http://linux.die.net/man/5/powerman.conf) Target Specification powerman target hostnames may be specified as comma-separated or space-separated hostnames or host ranges. Host ranges are of the general form: prefix[n-m,l-k,...], where n < m and l < k, etc., This form should not be confused with regular expression character classes (also denoted by ''[]''). For example, foo[19] does not represent foo1 or foo9, but rather represents a degenerate range: foo19.

This range syntax is meant only as a convenience on clusters with a prefix NN naming convention and specification of ranges should not be considered necessary -- the list foo1,foo9 could be specified as such, or by the range foo[1,9].

Some examples of powerman targets follows.

Power on hosts bar,baz,foo01,foo02,...,foo05: powerman --on bar baz foo[01-05]

Power on hosts bar,foo7,foo9,foo10powerman --on bar,foo[7,9-10]
Page 194 of the Tripp Lite B096-048 user manual — Adding new RPC devices
Page 194 · click to enlarge
Page 194
Power on foo0,foo4,foo5powerman --on foo[0,4-5]

As a reminder to the reader, some shells will interpret brackets ([ and ]) for pattern matching. Depending on your shell, it may be necessary to enclose ranged lists within quotes. For example, in tcsh, the last example above should be executed as:

pmpower

The pmpower command is a high-level tool for manipulating remote, preconfigured power devices connected to the Console Servers either via a serial or network connection.

pmpower [-?h] [-l device | -r host] [-o outlet] [-u username] [-p password] action

-?/-h This help message. -l The serial port to use. -o The outlet on the power target to apply to -r The remote host address for the power target -u Override the configured username -p Override the configured password on This action switches the specified device or outlet(s) ON off This action switches the specified device or outlet(s) OFF cycle This action switches the specified device or outlet(s) OFF and ON again status This action retrieves the current status of the device or outlet

Examples:

To turn outlet 4 of the power device connected to serial port 2 on:

# pmpower -l port02 -o 4 on

To turn an IPMI device located at IP address 192.168.1.100 to OFF (where username is 'root' and password is 'calvin':

# pmpower -r 192.168.1.100 -u root -p calvin off

Default system Power Device actions are specified in /etc/powerstrips.xml. Custom Power Devices can be added in /etc/config/powerstrips.xml. If an action is attempted which has not been configured for a specific Power Device, pmpower will exit with an error.

Adding new RPC devices

There are two simple paths to adding support for new RPC devices.

powerman --on "foo[0,4-5]"

Page 195 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 195 · click to enlarge
Page 195

The first is to have scripts to support the particular RPC included in the open source PowerMan project (http://sourceforge.net/projects/powerman). The PowerMan device specifications are unusual and it is suggested that you leave the actual writing of these scripts to the PowerMan authors. However documentation on how they work can be found at http://linux.die.net/man/5/powerman.dev. Once the new RPC support has been built into the PowerMan, we will include the updated PowerMan build in a subsequent firmware release.

The second path is to directly add support for the new RPC devices (or to customize the existing RPC device support) on your particular Console Server. The Manage: Power page uses information contained in /etc/powerstrips.xml to configure and control devices attached to a serial port. The configuration also looks for (and loads) /etc/config/powerstrips.xml if it exists.

The user can add their own support for more devices by putting definitions for them into /etc/config/powerstrips.xml. This file can be created on a host system and copied to the Management Console device using scp. Alternatively, login to the Management Console and use ftp or wget to transfer files.

Here is a brief description of the elements of the XML entries in /etc/config/powerstrips.xml.

<id>Name or ID of the device support</id>

<outlet port="port-id-1">Display Port 1 in menu</outlet>

<outlet port="port-id-2">Display Port 2 in menu</outlet>

<on>script to turn power on</on>

<off>script to power off</off>

<cycle>script to cycle power</cycle>

<status>script to write power status to /var/run/power-status</status>

The id appears on the web page in the list of available devices types to configure.

The outlets describe targets that the scripts can control. For example, a power control board may control several different outlets. The port-id is the native name for identifying the outlet.

Show 6 more labels / short text on this page
<powerstrip> · <speed>baud rate</speed> · <charsize>character size</charsize> · <stop>stop bits</stop> · <parity>parity setting</parity> · </powerstrip>
Page 196 of the Tripp Lite B096-048 user manual — 15.10 IPMItool
Page 196 · click to enlarge
Page 196

This value will be passed to the scripts in the environment variable outlet, allowing the script to address the correct outlet.

There are four possible scriptson, off, cycle and status

When a script is run, its standard input and output is redirected to the appropriate serial port. The script receives the outlet and port in the outlet and port environment variables respectively.

The script can be anything that can be executed within the shell.

All of the existing scripts in /etc/powerstrips.xml use the pmchat utility.

pmchat works just like the standard unix "chat" program, only it ensures interoperation with the port manager.

The final options, speed, charsize, stop and parity define the recommended or default settings for the attached device.

15.10 IPMItool

The Console Server includes the ipmitool utility for managing and configuring devices that support the Intelligent Platform Management Interface (IPMI) version 1.5 and version 2.0 specifications.

IPMI is an open standard for monitoring, logging, recovery, inventory, and control of hardware that is implemented independent of the main CPU, BIOS, and OS. The service processor (or Baseboard Management Controller, BMC) is the brain behind platform management and its primary purpose is to handle the autonomous sensor monitoring and event logging features.

The ipmitool program provides a simple command-line interface to this BMC. It features the ability to read the sensor data repository (SDR) and print sensor values, display the contents of the System Event Log (SEL), print Field Replaceable Unit (FRU) inventory information, read and set LAN configuration parameters, and perform remote chassis power control. SYNOPSIS ipmitool [-c|-h|-v|-V] -I open

ipmitool [-c|-h|-v|-V] -I lan -H [-p ]

Page 197 of the Tripp Lite B096-048 user manual — OPTIONS
Page 197 · click to enlarge
Page 197

[-U ] [-A ] [-L ] [-a|-E|-P|-f ] [-o ]

ipmitool [-c|-h|-v|-V] -I lanplus -H [-p ] [-U ] [-L ] [-a|-E|-P|-f ] [-o ] [-C ]

DESCRIPTION

This program lets you manage Intelligent Platform Management Interface (IPMI) functions of either the local system, via a kernel device driver, or a remote system, using IPMI V1.5 and IPMI v2.0. These functions include printing FRU information, LAN configuration, sensor readings, and remote chassis power control.

IPMI management of a local system interface requires a compatible IPMI kernel driver to be installed and configured. On Linux, this driver is called OpenIPMI and it is included in standard distributions. On Solaris, this driver is called BMC and is included in Solaris 10. Management of a remote station requires the IPMI-over-LAN interface to be enabled and configured. Depending on the particular requirements of each system, it may be possible to enable the LAN interface using ipmitool over the system interface.

OPTIONS

-a Prompt for the remote server password. -A

Specify an authentication type to use during IPMIv1.5 lan session activation. Supported types are NONE, PASSWORD, MD5, or OEM. -c Present output in CSV (comma separated variable) format. This is not available with all commands. -C

The remote server authentication, integrity, and encryption algorithms to use for IPMIv2 lanplus connections. See table 22-19 in the IPMIv2 specification. The default is 3 which specifies RAKP-HMAC-SHA1 authentication, HMAC-SHA1-96 integrity, and AES-CBC-128 encryption algorightms. -E The remote server password is specified by the environment variable IPMI_PASSWORD.

Page 198 of the Tripp Lite B096-048 user manual — SECURITY
Page 198 · click to enlarge
Page 198

-f

Specifies a file containing the remote server password. If this option is absent, or if password_file is empty, the password will default to NULL. -h Get basic usage help from the command line. -H

Remote server address can be an IP address or hostname. This option is required for lan and lanplus interfaces. -I

Selects IPMI interface to use. Supported interfaces that are compiled in and visible in the usage help output. -L

Force session privilege level. Can be CALLBACK, USER, OPERATOR, ADMIN. Default is ADMIN. -m

Set the local IPMB address. The default is 0x20 and there should be no need to change it for normal operation. -o

Select OEM type to support. This usually involves minor hacks in place in the code to work around quirks in various BMCs from various manufacturers. Use -o list to see a list of current supported OEM types. -p

Remote server UDP port to connect to. Default is 623. -P

Remote server password is specified on the command line. If supported, it will be obscured in the process list. Note! Specifying the password as a command line option is not recommended. -t

Bridge IPMI requests to the remote target address. -U

Remote server username, default is NULL user. -v Increase verbose output level. This option may be specified multiple times to increase the level of debug output. If given three times, you will get hexdumps of all incoming and outgoing packets. -V Display version information.

If no password method is specified, then ipmitool will prompt the user for a password. If no password is entered at the prompt, the remote server password will default to NULL.

SECURITY

The ipmitool documentation highlights that there are several security issues to be considered before enabling the IPMI LAN interface. A remote station has the ability to control a system's power state as well as being able to gather certain platform information. To reduce vulnerability, it is strongly advised that the IPMI LAN interface only be enabled in 'trusted'

Page 199 of the Tripp Lite B096-048 user manual — COMMANDS
Page 199 · click to enlarge
Page 199

environments where system security is not an issue or where there is a dedicated secure 'management network' or access has been provided through an Console Server.

Further, it is strongly advised that you should not enable IPMI for remote access without setting a password, and that the password should not be the same as any other password on that system.

When an IPMI password is changed on a remote machine with the IPMIv1.5 lan interface, the new password is sent across the network as clear text. This could be observed and then used to attack the remote system. It is thus recommended that IPMI password management only be done over IPMIv2.0 lanplus interface or the system interface on the local station.

For IPMI v1.5, the maximum password length is 16 characters. Passwords longer than 16 characters will be truncated.

For IPMI v2.0, the maximum password length is 20 characters; longer passwords are truncated.

COMMANDS

This can be used to get command-line help on ipmitool commands. It may also be placed at the end of commands to get option usage help.

Commands: raw Send a RAW IPMI request and print response lan Configure LAN Channels chassis Get chassis status and set power state event Send pre-defined events to MC mc Management Controller status and global enables sdr Print Sensor Data Repository entries and readings sensor Print detailed sensor information fru Print built-in FRU and scan SDR for FRU locators sel Print System Event Log (SEL) pef Configure Platform Event Filtering (PEF) sol Configure IPMIv2.0 Serial-over-LAN isol Configure IPMIv1.5 Serial-over-LAN user Configure Management Controller users channel Configure Management Controller channels session Print session information exec Run list of commands from file set Set runtime variable for shell and exec

help · ipmitool help

Page 200 of the Tripp Lite B096-048 user manual — 15.11 Scripts for Managing Slaves
Page 200 · click to enlarge
Page 200
Chassis Commandsstatus, power, identify, policy, restart_cause, poh, bootdev

ipmitool chassis power help

chassis power Commandsstatus, on, off, cycle, reset, diag, soft

You will find more details on ipmitools at http://ipmitool.sourceforge.net/manpage.html

15.11 Scripts for Managing Slaves

When the Console Servers are cascaded, the Master is in control of the serial ports on the Slaves, and the Master’s Management Console provides a consolidated view of the settings for its own and all the Slave’s serial ports. However, the Master does not provide a fully consolidated view, e.g. Status: Active Users. It only displays those users active on the Master’s ports. You will need to write a custom bash script that parses the port logs if you want to find out who's logged in to cascaded serial ports from the master.

You will probably also want to enable remote or USB logging, as local logs only buffer 8K of data and don't persist between reboots. This script would parse each port log file line by line. Each time it sees 'LOGIN: username', it adds the username to the list of connected users for that port, each time it sees 'LOGOUT: username' it removes it from the list. The list can then be nicely formatted and displayed. It is also possible to run this as a CGI script on the B092-016. In this case, the remote/USB logged port logs files are in: /var/run/portmanager/logdir (or they are in /var/log). Otherwise you can run the script on the remote log server. To enable log storage and connection logging: - Select Alerts & Logging: Port Log - Configure log storage - Select Serial & Network: Serial Port, Edit the serial port(s) - Under Console Server, select Logging Level 1 and click Apply To run the CGI script on the Console Server: - Login to the B092-016 - Run: mount -o remount,rw /dev/hda1 / - Copy the script to /home/httpd/cgi-bin/ - Run: mount -o remount,ro /dev/hda1 / - Browse to: http://192.168.0.1/cgi-bin/yourscript.cgi where 192.168.0.1 is the IP address of the Console Server and yourscript.cgi is the name of the script There is a useful tutorial on creating a bash script CGI at http://www.yolinux.com/TUTORIALS/LinuxTutorialCgiShellScript.html Similarly the Master maintains a view of the status of the Slaves:

ipmitool chassis help

Page 201 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 201 · click to enlarge
Page 201

- Select Status: Support Report - Scroll down to Processes - Look for: /bin/ssh -MN -o ControlPath=/var/run/cascade/%h Slavename - These are the Slaves that are connected - Note: The end of the Slaves' names will be truncated, so the first 5 characters must be unique Alternatively, you can write a custom CGI script as described above. The currently connected Slaves can be determined by running: ls /var/run/cascade and the configured Slaves can be displayed by running: config -g config.cascade.Slaves

Page 202 of the Tripp Lite B096-048 user manual — 16.1 Local Client Service Connections
Page 202 · click to enlarge
Page 202

16. THIN CLIENT (B092-016)

Introduction

The B092-016 has a selection of management clients (Firefox browser, SSH, Telnet, VNC viewer, ICA, RDP) embedded as well as the Tripp Lite PowerAlert software. With these, the B092-016 provides rackside control of computers, networking, telecom, power and other managed devices via serial, USB or IP over the LAN.

This chapter provides instructions on configuring the thin clients and using them locally and remotely. The thin clients can be controlled from the rack side using a direct monitor/keyboard/mouse connected to the B092-016 or remotely using a VNC connection from the remote user to the B092-016.

16.1 Local Client Service Connections

These client connections first need to be configured:

¾ Select ConnectAdd/Delete/Edit on the control panel
Tripp Lite B096-048 — 16.1 Local Client Service Connections diagram (page 202)
Fig. 179 · 16.1 Local Client Service Connections

¾ Then select a Connect client (such as RDP) and click Add to configure the Host connection for

that client service

Page 203 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 203 · click to enlarge
Page 203
Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 203)
Fig. 180

¾ For each new Host you add, you will be asked to enter a Label (enter a descriptive name) and a

Hostname (enter the IP Address or DNS Name of the new network connected Host) and possibly a Username (enter the name you will use to log in to the Host)

¾ Once a Host has been added, you can select Edit and update the commands that will be

executed in connecting the service to the existing Host

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 203)
Fig. 181

¾ The sixteen serial ports are pre-configured by default in Console Server mode for the B096-016 /

B096-048 Console Server Management Switch or in UPS (PowerAlert) mode for the B092-016 Console Server with PowerAlert product. To change these settings, select Configure, which will load the local Firefox browser and run the Management Console. You can then reconfigure the serial ports as detailed in Chapter 4

Page 204 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 204 · click to enlarge
Page 204
Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 204)
Fig. 182

16.1.1 Connect- serial terminal

¾ Select Connect: Serial on the control panel and click on the desired serial port. A window will be

created with a connection to the device on the selected serial port:

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 204)
Fig. 183

The embedded terminal emulator uses rxvt (a color vt102 terminal emulator). You can find more details on configuration options in http://www.rxvt.org/manual.html

16.1.2 Connect- browser

¾ Select Connect: Browser on the control panel and click on the Host/web site you have configured to

be accessed using the browser. Sites can be internal or external.

Page 205 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 205 · click to enlarge
Page 205
Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 205)
Fig. 184

The B092-016 provides a powerful Mozilla Firefox browser with a licensed Sun Java JRE

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 205)
Fig. 185
Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 205)
Fig. 186

Java and all Java based trademarks and logos are trademarks or registered trademarks of Sun Microsystems, Inc. in the U.S. and other countries

16.1.3 Connect- VNC

¾ Select Connect: VNC on the control panel and click on the VNC server Host to be accessed

¾ The VNC Viewer client in your B092-016 will be started and a VNC connection window to the

selected server will be opened

Page 206 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 206 · click to enlarge
Page 206
Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 206)
Fig. 187

¾ If the HostName was left blank when the VNC server connection was configured, then the VNC

Viewer will start with a request for the VNC server.

¾ Selecting Options at this stage enables you to configure the VNC Viewer

¾ Alternately, you can select Options by right-clicking

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 206)
Fig. 188

on the VNC Viewer task Bar icon

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 206)
Fig. 189

You can find more details on configuration options in

http://www.realvnc.com/products/free/4.1/man/vncviewer.html

16.1.4 Connect- SSH

SSH is typically used to log into a remote machine and execute commands.

¾ Select ConnectSSH on the control panel and click on the Host to be accessed

¾ An SSH connection window will be opened. Enter the SSH login password and you will be securely

connected to the selected Host

Page 207 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 207 · click to enlarge
Page 207
Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 207)
Fig. 190

The B092-016 SSH connection uses OpenSSH (http://www.openssh.com/) and the terminal connection is presented using rxvt (ouR XVT). You can find more details on configuration options in http://www.rxvt.org/manual.html

16.1.5 Connect- IPMI

The B092-016 control panel provides a number of IPMI tools for managing service processors or Baseboard Management Controllers (BMCs). These IPMI controls are built on the ipmitools program. Find more details on configuration options in http://ipmitool.sourceforge.net/manpage.html

The ipmitool program provides a simple command-line interface to the BMCs and features the ability to read the sensor data repository (SDR), display the contents of the System Event Log (SEL), read and set LAN configuration parameters, and perform remote chassis power control. The B092-016 Management Console also has additional tools for controlling power units with IPMI interfaces (refer to Chapter 8).

¾ Select Connect: IPMI on the control panel and select the Serial over LAN connection to be accessed

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 207)
Fig. 191

This will launch a Serial-Over-LAN session by running:

# ipmitool -I lanplus -H hostname -U username -P password sol activate

Page 208 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 208 · click to enlarge
Page 208

The resulting serial character connection is presented in an rxvt (ouR XVT) window. Also the Serial-Over- LAN feature is only applicable to IPMI2.0 devices.

¾ Select LogsIPMI on the control panel and select the IPMI Event Log to be viewed
Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 208)
Fig. 192

This will retrieve the selected IPMI event log by running:

# ipmitool -I lanplus -H hostname -U username -P password sel info

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 208)
Fig. 193

16.1.6 Connect- Remote Desktop (RDP)

¾ Select ConnectRDP on the control panel and click on the Windows computer to be accessed
Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 208)
Fig. 194

¾ The rdesktop program in your B092-016 will be started, an RDP connection to the Remote Desktop server in the selected computer will be opened, the rdesktop window will appear on your B092-016 screen and you will be prompted for a password. (If the selected computer does not have RDP access enabled, then the rdesktop window will not appear.)

Page 209 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 209 · click to enlarge
Page 209
Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 209)
Fig. 195

You can use Add/Delete/Edit to customize the rdesktop client (e.g. to include login username passwords). The command line protocol is:

rdesktop -u windows-user-id -p windows-password -g 1200x950 ms-windows-terminal-server- host-name

Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 209)
Fig. 196

-r Device redirection. i.e. Redirect sound on remote machine to local device i.e. -0 -r sound (MS/Windows 2003)

-g Geometry: widthxheight or 70% screen percentage.

Further information on rdesktop can be found at http://www.rdesktop.org/

16.1.7 Connect- Citrix ICA

¾ Select Connect: Citrix ICA on the control panel and click on the Citrix server to be accessed

Page 210 of the Tripp Lite B096-048 user manual — 16.2 Advanced Control Panel
Page 210 · click to enlarge
Page 210
Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 210)
Fig. 197

16.1.8 Connect- PowerAlert

¾ Select Connect: PowerAlert on the control panel. The PowerAlert software will be launched.

16.2 Advanced Control Panel

16.2.1 SystemTerminal

Selecting System: Terminal on the control panel logs you in at the command line to the B092-016 Linux kernel. As detailed in Chapters 14 and 15, this enables you to configure and customize your B092-016 using the config and portmanager commands or general Linux commands.

Page 211 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 211 · click to enlarge
Page 211
Tripp Lite B096-048 — POWER & ENVIRONMENTAL MANAGEMENT diagram (page 211)
Fig. 198
16.2.2 SystemShutdown / Reboot

Clicking System: Shutdown on the control panel will shut down the B092-016 system. You will need to cycle the power to reactivate the B092-016 with a soft reset.

Similarly, by clicking System: Reboot, you will initiate a soft reset. With a soft reset, the B092-016 reboots with all settings such as the assigned network IP address, preserved. However a soft reset disconnects all Users and ends any SSH sessions that had been established.

A soft reset will also occur when you switch OFF power from the B092-016, and then switch the power back ON. However, if you cycle the power while the unit is writing to flash, you could corrupt or lose data, so the software Shutdown or Reboot from the control panel is the safer option.

16.2.3 SystemLogout

Clicking System: Logout closes the local user log in session (and removes the control panel). However, this does not logout remote users who may be logged into the B092-016 Console Server, or accessing attached devices using SSH tunneling.

16.2.4 Custom

The Custom button on the control panel enables you to customize your B092-016 by adding buttons to the control panel that execute bash and other Linux commands you specify.

16.2.5 Status

These menu items give the user a snapshot of the serial port and IPMI device status.

16.2.6 Logs

These menu items give the user an audit log of B092-016 activity.

Page 212 of the Tripp Lite B096-048 user manual — 16.3 Remote control
Page 212 · click to enlarge
Page 212

16.3 Remote control

You can access the B092-016 locally via a directly connected keyboard, monitor and mouse (or KVM switch). If the B092-016 is connected to a KVMoIP infrastructure, then this may also provide you with some remote access to the B092-016 local consoles (RDP, Telnet, VNC, ICA, JRE etc).

The B092-016 also hosts an embedded VNC server that enables you to remotely monitor and control the thin client software (RDP, Telnet, VNC, ICA etc) that is running in the B092-016 itself.

securely connect the client directly to the managed devices that are serially or network attached to the B092-016. This is useful when running proprietary applications (such as Dell OpenManage) or Windows applications (such as VMware VDI client) on a remote management computer which is be used to manage a DRAC service processor or VMware virtual device on a remote server.

Each B092-016 gateway has an internal VNC server enabling remote administrators to oversee local activity, and giving them the option to access and control all the devices themselves. To activate the VNC server in the B092-016:

¾ Select the SystemServices option in the Management Console menu then check VNC Server or
¾ Click ManageKVM Console Server then Launch Standard VNC Remote Control and your browser

will automatically download and run a Java VNC applet client

¾ Log in as root (or some other configured B092-016 username) and as a remote Administrator you

can then connect to the VNC server in the B092-016 and gain remote access to (and monitor and take control of) the B092-016 local display

You can find more details on configuration options for the B092-016 realvnc server in http://www.realvnc.com/products/free/4.1/man/vncserver.html

remote computer and configure it with the B092-016’s IP address to connect to the B092-016 VNC server

Tripp Lite B096-048 — 16.3 Remote control diagram (page 212)
Fig. 199 · 16.3 Remote control

Secure VNC Server

Page 213 of the Tripp Lite B096-048 user manual — FEATURE VALUE
Page 213 · click to enlarge
Page 213

Appendix A Hardware Specification

FEATURE VALUE

Dimensions B096-016 / B096-04817 x 12 x 1.75 in (43.2 x 31.3. x 4.5 cm)
B092-01617 x 6.7 x 1.75 in (44 x 17 x 4.5 cm)
Weight B096-016 / B096-04811.8 lbs (5.4 kg)
B092-0168.5 lb (3.9 kg)

Ambient operating temperature 41°F to 122°F (5°C to 50°C)

-20°F to +140°F (-30°C to +60°C)

Humidity 5% to 90%

Power Refer to Chapter 2

Non-operating storage temperature

Page 214 of the Tripp Lite B096-048 user manual — FEMALE MALE
Page 214 · click to enlarge
Page 214

Appendix B Serial Port Connectivity

Pinout standards exist for both DB9 and DB25 connectors, however, there are not pinout standards for serial connectivity using RJ45 connectors. Many Console Servers and serially managed servers/ router/ switches/ PSUs have adopted their own unique pinout; so custom connectors and cables may be required to interconnect your Console Server. In an endeavor to create some move to standardization, Tripp Lite Console Server products all use the same RJ45 pinout convention as adopted by Cisco, SUN and others.

Serial Port Pinout

The 16/48 RJ45 connectors on the B092-016 Console Server with PowerAlert, and the B096-048/016 Console Server Management Switch have the following pinout:

Tripp Lite B096-048 — Serial Port Pinout diagram (page 214)
Fig. 200 · Serial Port Pinout

PIN SIGNAL DEFINITION DIRECTION 1 CTS Clear To Send Input 2 DSR Data Set Ready Input 3 RXD Receive Data Input 4 GND Signal Ground NA 5 GND Signal Ground NA 6 TXD Transmit Data Output 7 DTR Data Terminal Ready Output 8 RTS Request To Send Output The LOCAL (console/modem) port on the Console Server uses a standard DB9 connector as tabled below:

SIGNAL DB9 Pin DEFINITION

TXD 3 Transmitted Data

RXD 2 Received Data

RTS 7 Request To Send

CTS 8 Clear To Send

DSR 6 Data Set Ready

GND 5 Signal Ground

CD 1 Received Line Signal Detector

DTR 4 Data Terminal Ready

RI 9 Ring Indicator

FEMALE MALE

9 pin DB9

Page 215 of the Tripp Lite B096-048 user manual — Connectors included in Console Server
Page 215 · click to enlarge
Page 215

Connectors included in Console Server

The B092-016 Console Server with PowerAlert, and the B096-048/016 Console Server Management Switch ship with a “cross-over” and a “straight” RJ45-DB9 connector for connecting to other vendor’s products: O E

Tripp Lite B096-048 — Connectors included in Console Server diagram (page 215)
Fig. 201 · Connectors included in Console Server
Tripp Lite B096-048 — Connectors included in Console Server diagram (page 215)
Fig. 202 · Connectors included in Console Server

DB9F-RJ45S straight connector · DB9F-RJ45S cross-over connector

Page 216 of the Tripp Lite B096-048 user manual — READ BEFORE USING THE ACCOMPANYING SOFTWARE
Page 216 · click to enlarge
Page 216

Appendix C End User License Agreement

READ BEFORE USING THE ACCOMPANYING SOFTWARE

YOU SHOULD CAREFULLY READ THE FOLLOWING TERMS AND CONDITIONS BEFORE USING THE ACCOMPANYING SOFTWARE, THE USE OF WHICH IS LICENSED FOR USE ONLY AS SET FORTH BELOW. IF YOU DO NOT AGREE TO THE TERMS AND CONDITIONS OF THIS AGREEMENT, DO NOT USE THE SOFTWARE. IF YOU USE ANY PART OF THE SOFTWARE, SUCH USE WILL INDICATE THAT YOU ACCEPT THESE TERMS.

You have acquired a product that includes Tripp Lite (“Tripp Lite”) proprietary software and/or proprietary software licensed to Tripp Lite. This Tripp Lite End User License Agreement (“EULA”) is a legal agreement between you (either an individual or a single entity) and Tripp Lite for the installed software product of Tripp Lite origin, as well as associated media, printed materials, and “online” or electronic documentation (“Software”). By installing, copying, downloading, accessing, or otherwise using the Software, you agree to be bound by the terms of this EULA. If you do not agree to the terms of this EULA, Tripp Lite is not willing to license the Software to you. In such event, do not use or install the Software. If you have purchased the Software, promptly return the Software and all accompanying materials with proof of purchase for a refund.

Products with separate end user license agreements that may be provided along with the Software are licensed to you under the terms of those separate end user license agreements.

LICENSE GRANT. Subject to the terms and conditions of this EULA, Tripp Lite grants you a nonexclusive right and license to install and use the Software on a single CPU, provided that, (1) you may not rent, lease, sell, sublicense or lend the Software; (2) you may not reverse engineer, decompile, disassemble or modify the Software, except and only to the extent that such activity is expressly permitted by applicable law notwithstanding this limitation; and (3) you may not transfer rights under this EULA unless such transfer is part of a permanent sale or transfer of the Product, you transfer at the same time all copies of the Software to the same party or destroy such materials not transferred, and the recipient agrees to this EULA.

No license is granted in any of the Software’s proprietary source code. This license does not grant you any rights to patents, copyright, trade secrets, trademarks or any other rights with respect to the Software.

You may make a reasonable number of copies of the electronic documentation accompanying the Software for each Software license you acquire, provided that, you must reproduce and include all copyright notices and any other proprietary rights notices appearing on the electronic documentation. Tripp Lite reserves all rights not expressly granted herein.

INTELLECTUAL PROPERTY RIGHTS. The Software is protected by copyright laws, international copyright treaties, and other intellectual property laws and treaties. Tripp Lite and its suppliers retain all ownership of, and intellectual property rights in (including copyright), the Software components and all copies thereof, provided however, that (1) certain components of the Software, including SDT Connector, are components licensed under the GNU General Public License Version 2, which Tripp Lite supports, and (2) the SDT Connector includes code from JSch, a pure Java implementation of SSH2 which is licensed under BSD style license. Copies of these licenses are detailed below and Tripp Lite will provide source code for any of the components of the Software licensed under the GNU General Public License upon request.

Page 217 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 217 · click to enlarge
Page 217

EXPORT RESTRICTIONS. You agree that you will not export or re-export the Software, any part thereof, or any process or service that is the direct product of the Software in violation of any applicable laws or regulations of the United States or the country in which you obtained them.

U.S. GOVERNMENT RESTRICTED RIGHTS. The Software and related documentation are provided with Restricted Rights. Use, duplication, or disclosure by the Government is subject to restrictions set forth in subparagraph (c) (1) (ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013 or subparagraphs (c) (1) and (2) of the Commercial Computer Software – Restricted Rights at 48 C.F.R. 52.227-19, as applicable, or any successor regulations.

TERM AND TERMINATION. This EULA is effective until terminated. The EULA terminates immediately if you fail to comply with any term or condition. In such an event, you must destroy all copies of the Software. You may also terminate this EULA at any time by destroying the Software.

GOVERNING LAW AND ATTORNEY’S FEES. This EULA is governed by the laws of the State of Utah, USA, excluding its conflict of law rules. You agree that the United Nations Convention on Contracts for the International Sale of Goods is hereby excluded in its entirety and does not apply to this EULA. If you acquired this Software in a country outside of the United States, that country’s laws may apply. In any action or suit to enforce any right or remedy under this EULA or to interpret any provision of this EULA, the prevailing party will be entitled to recover its costs, including reasonable attorneys’ fees.

ENTIRE AGREEMENT. This EULA constitutes the entire agreement between you and Tripp Lite with respect to the Software, and supersedes all other agreements or representations, whether written or oral. The terms of this EULA can only be modified by express written consent of both parties. If any part of this EULA is held to be unenforceable as written, it will be enforced to the maximum extent allowed by applicable law, and will not affect the enforceability of any other part.

Should you have any questions concerning this EULA, or if you desire to contact Tripp Lite for any reason, please contact the Tripp Lite representative serving your company.

THE FOLLOWING DISCLAIMER OF WARRANTY AND LIMITATION OF LIABILITY IS INCORPORATED INTO THIS EULA BY REFERENCE. THE SOFTWARE IS NOT FAULT TOLERANT. YOU HAVE INDEPENDENTLY DETERMINED HOW TO USE THE SOFTWARE IN THE DEVICE, AND TRIPPLITE HAS RELIED UPON YOU TO CONDUCT SUFFICIENT TESTING TO DETERMINE THAT THE SOFTWARE IS SUITABLE FOR SUCH USE.

LIMITED WARRANTY Tripp Lite warrants the media containing the Software for a period of ninety (90) days from the date of original purchase from Tripp Lite or its authorized retailer. Proof of date of purchase will be required. Any updates to the Software provided by Tripp Lite (which may be provided by Tripp Lite at its sole discretion) shall be governed by the terms of this EULA. In the event the product fails to perform as warranted, Tripp Lite’s sole obligation shall be, at Tripp Lite’s discretion, to refund the purchase price paid by you for the Software on the defective media, or to replace the Software on new media. Tripp Lite makes no warranty or representation that its Software will meet your requirements, will work in combination with any hardware or application software products provided by third parties, that the operation of the software products will be uninterrupted or error free, or that all defects in the Software will be corrected.

TRIPP LITE DISCLAIMS ANY AND ALL OTHER WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. OTHER THAN AS STATED HEREIN, THE ENTIRE RISK AS TO SATISFACTORY QUALITY, PERFORMANCE, ACCURACY, AND EFFORT IS WITH YOU. ALSO, THERE IS NO WARRANTY AGAINST INTERFERENCE WITH YOUR ENJOYMENT OF THE SOFTWARE OR AGAINST INFRINGEMENT. IF YOU HAVE RECEIVED ANY WARRANTIES

Page 218 of the Tripp Lite B096-048 user manual — SDT Connector License
Page 218 · click to enlarge
Page 218

REGARDING THE DEVICE OR THE SOFTWARE, THOSE WARRANTIES DO NOT ORIGINATE FROM, AND ARE NOT BINDING ON, TRIPP LITE.

NO LIABILITY FOR CERTAIN DAMAGES. EXCEPT AS PROHIBITED BY LAW, TRIPP LITE SHALL HAVE NO LIABILITY FOR COSTS, LOSS, DAMAGES OR LOST OPPORTUNITY OF ANY TYPE WHATSOEVER, INCLUDING BUT NOT LIMITED TO, LOST OR ANTICIPATED PROFITS, LOSS OF USE, LOSS OF DATA, OR ANY INCIDENTAL, EXEMPLARY SPECIAL OR CONSEQUENTIAL DAMAGES, WHETHER UNDER CONTRACT, TORT, WARRANTY OR OTHERWISE ARISING FROM OR IN CONNECTION WITH THIS EULA OR THE USE OR PERFORMANCE OF THE SOFTWARE. IN NO EVENT SHALL TRIPPLITE BE LIABLE FOR ANY AMOUNT IN EXCESS OF THE LICENSE FEE PAID TO TRIPPLITE UNDER THIS EULA. SOME STATES AND COUNTRIES DO NOT ALLOW THE LIMITATION OR EXCLUSION OF LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THIS LIMITATION MAY NOT APPLY TO YOU.

JSch License

SDT Connector includes code from JSch, a pure Java implementation of SSH2. JSch is licensed under BSD style license and it is: Copyright (c) 2002, 2003, 2004 Atsuhiko Yamanaka, JCraft,Inc. All rights reserved. Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: 1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following

disclaimer. 2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following

disclaimer in the documentation and/or other materials provided with the distribution. 3. The names of the authors may not be used to endorse or promote products derived from this software without

specific prior written permission. THIS SOFTWARE IS PROVIDED ``AS IS'' AND ANY EXPRESSED OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL JCRAFT, INC. OR ANY CONTRIBUTORS TO THIS SOFTWARE BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

SDT Connector License

GNU GENERAL PUBLIC LICENSE

Version 2, June 1991

Copyright (C) 1989, 1991 Free Software Foundation, Inc. 51 Franklin Street, Fifth Floor, Boston, MA 02110-1301, USA

Page 219 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 219 · click to enlarge
Page 219

Everyone is permitted to copy and distribute verbatim copies of this license document, but changing it is not allowed.

GNU GENERAL PUBLIC LICENSE TERMS AND CONDITIONS FOR COPYING, DISTRIBUTION AND MODIFICATION 0. This License applies to any program or other work which contains a notice placed by the copyright holder saying it may be distributed under the terms of this General Public License. The "Program", below, refers to any such program or work, and a "work based on the Program" means either the Program or any derivative work under copyright law: that is to say, a work containing the Program or a portion of it, either verbatim or with modifications and/or translated into another language. (Hereinafter, translation is included without limitation in the term "modification".) Each licensee is addressed as "you". Activities other than copying, distribution and modification are not covered by this License; they are outside its scope. The act of running the Program is not restricted, and the output from the Program is covered only if its contents constitute a work based on the Program (independent of having been made by running the Program). Whether that is true depends on what the Program does. 1. You may copy and distribute verbatim copies of the Program's source code as you receive it, in any medium, provided that you conspicuously and appropriately publish on each copy an appropriate copyright notice and disclaimer of warranty; keep intact all the notices that refer to this License and to the absence of any warranty; and give any other recipients of the Program a copy of this License along with the Program. You may charge a fee for the physical act of transferring a copy, and you may at your option offer warranty protection in exchange for a fee. 2. You may modify your copy or copies of the Program or any portion of it, thus forming a work based on the Program, and copy and distribute such modifications or work under the terms of Section 1 above, provided that you also meet all of these conditions: a) You must cause the modified files to carry prominent notices stating that you changed the files and the date of any change. b) You must cause any work that you distribute or publish, that in whole or in part contains or is derived from the Program or any part thereof, to be licensed as a whole at no charge to all third parties under the terms of this License. c) If the modified program normally reads commands interactively when run, you must cause it, when started running for such interactive use in the most ordinary way, to print or display an announcement including an appropriate copyright notice and a notice that there is no warranty (or else, saying that you provide a warranty) and that users may redistribute the program under these conditions, and telling the user how to view a copy of this License. (Exception: if the Program itself is interactive but does not normally print such an announcement, your work based on the Program is not required to print an announcement.) These requirements apply to the modified work as a whole. If identifiable sections of that work are not derived from the Program, and can be reasonably considered independent and separate works in themselves, then this License, and its terms, do not apply to those sections when you distribute them as separate works. But when you distribute the same sections as part of a whole which is a work based on the Program, the distribution of the whole must be on the terms of this License, whose permissions for other licensees extend to the entire whole, and thus to each and every part regardless of who wrote it. Thus, it is not the intent of this section to claim rights or contest your rights to work written entirely by you; rather, the intent is to exercise the right to control the distribution of derivative or collective works based on the Program. In addition, mere aggregation of another work not based on the Program with the Program (or with a work based on the Program) on a volume of a storage or distribution medium does not bring the other work under the scope of this License. 3. You may copy and distribute the Program (or a work based on it, under Section 2) in object code or executable form under the terms of Sections 1 and 2 above provided that you also do one of the following:

Page 220 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 220 · click to enlarge
Page 220

a) Accompany it with the complete corresponding machine-readable source code, which must be distributed under the terms of Sections 1 and 2 above on a medium customarily used for software interchange; or, b) Accompany it with a written offer, valid for at least three years, to give any third party, for a charge no more than your cost of physically performing source distribution, a complete machine-readable copy of the corresponding source code, to be distributed under the terms of Sections 1 and 2 above on a medium customarily used for software interchange; or, c) Accompany it with the information you received as to the offer to distribute corresponding source code. (This alternative is allowed only for noncommercial distribution and only if you received the program in object code or executable form with such an offer, in accord with Subsection b above.) The source code for a work means the preferred form of the work for making modifications to it. For an executable work, complete source code means all the source code for all modules it contains, plus any associated interface definition files, plus the scripts used to control compilation and installation of the executable. However, as a special exception, the source code distributed need not include anything that is normally distributed (in either source or binary form) with the major components (compiler, kernel, and so on) of the operating system on which the executable runs, unless that component itself accompanies the executable. If distribution of executable or object code is made by offering access to copy from a designated place, then offering equivalent access to copy the source code from the same place counts as distribution of the source code, even though third parties are not compelled to copy the source along with the object code. 4. You may not copy, modify, sublicense, or distribute the Program except as expressly provided under this License. Any attempt otherwise to copy, modify, sublicense or distribute the Program is void, and will automatically terminate your rights under this License. However, parties who have received copies, or rights, from you under this License will not have their licenses terminated so long as such parties remain in full compliance. 5. You are not required to accept this License, since you have not signed it. However, nothing else grants you permission to modify or distribute the Program or its derivative works. These actions are prohibited by law if you do not accept this License. Therefore, by modifying or distributing the Program (or any work based on the Program), you indicate your acceptance of this License to do so, and all its terms and conditions for copying, distributing or modifying the Program or works based on it. 6. Each time you redistribute the Program (or any work based on the Program), the recipient automatically receives a license from the original licensor to copy, distribute or modify the Program subject to these terms and conditions. You may not impose any further restrictions on the recipients' exercise of the rights granted herein. You are not responsible for enforcing compliance by third parties to this License. 7. If, as a consequence of a court judgment or allegation of patent infringement or for any other reason (not limited to patent issues), conditions are imposed on you (whether by court order, agreement or otherwise) that contradict the conditions of this License, they do not excuse you from the conditions of this License. If you cannot distribute so as to satisfy simultaneously your obligations under this License and any other pertinent obligations, then as a consequence you may not distribute the Program at all. For example, if a patent license would not permit royalty-free redistribution of the Program by all those who receive copies directly or indirectly through you, then the only way you could satisfy both it and this License would be to refrain entirely from distribution of the Program. If any portion of this section is held invalid or unenforceable under any particular circumstance, the balance of the section is intended to apply and the section as a whole is intended to apply in other circumstances. It is not the purpose of this section to induce you to infringe any patents or other property right claims or to contest validity of any such claims; this section has the sole purpose of protecting the integrity of the free software distribution system, which is implemented by public license practices. Many people have made generous contributions to the wide range of software distributed through that system in reliance on consistent application of that system; it is up to the author/donor to decide if he or she is willing to distribute software through any other system and a licensee cannot impose that choice. This section is intended to make thoroughly clear what is believed to be a consequence of the rest of this License. 8. If the distribution and/or use of the Program is restricted in certain countries either by patents or by copyrighted interfaces, the original copyright holder who places the Program under this License may add an explicit geographical

Page 221 of the Tripp Lite B096-048 user manual — SUN Java License
Page 221 · click to enlarge
Page 221

distribution limitation excluding those countries, so that distribution is permitted only in or among countries not thus excluded. In such case, this License incorporates the limitation as if written in the body of this License. 9. The Free Software Foundation may publish revised and/or new versions of the General Public License from time to time. Such new versions will be similar in spirit to the present version, but may differ in detail to address new problems or concerns. Each version is given a distinguishing version number. If the Program specifies a version number of this License which applies to it and "any later version", you have the option of following the terms and conditions either of that version or of any later version published by the Free Software Foundation. If the Program does not specify a version number of this License, you may choose any version ever published by the Free Software Foundation. 10. If you wish to incorporate parts of the Program into other free programs whose distribution conditions are different, write to the author to ask for permission. For software which is copyrighted by the Free Software Foundation, write to the Free Software Foundation; we sometimes make exceptions for this. Our decision will be guided by the two goals of preserving the free status of all derivatives of our free software and of promoting the sharing and reuse of software generally. NO WARRANTY 11. BECAUSE THE PROGRAM IS LICENSED FREE OF CHARGE, THERE IS NO WARRANTY FOR THE PROGRAM, TO THE EXTENT PERMITTED BY APPLICABLE LAW. EXCEPT WHEN OTHERWISE STATED IN WRITING THE COPYRIGHT HOLDERS AND/OR OTHER PARTIES PROVIDE THE PROGRAM "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE ENTIRE RISK AS TO THE QUALITY AND PERFORMANCE OF THE PROGRAM IS WITH YOU. SHOULD THE PROGRAM PROVE DEFECTIVE, YOU ASSUME THE COST OF ALL NECESSARY SERVICING, REPAIR OR CORRECTION. 12. IN NO EVENT UNLESS REQUIRED BY APPLICABLE LAW OR AGREED TO IN WRITING WILL ANY COPYRIGHT HOLDER, OR ANY OTHER PARTY WHO MAY MODIFY AND/OR REDISTRIBUTE THE PROGRAM AS PERMITTED ABOVE, BE LIABLE TO YOU FOR DAMAGES, INCLUDING ANY GENERAL, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE THE PROGRAM (INCLUDING BUT NOT LIMITED TO LOSS OF DATA OR DATA BEING RENDERED INACCURATE OR LOSSES SUSTAINED BY YOU OR THIRD PARTIES OR A FAILURE OF THE PROGRAM TO OPERATE WITH ANY OTHER PROGRAMS), EVEN IF SUCH HOLDER OR OTHER PARTY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. END OF TERMS AND CONDITIONS

SUN Java License

(B092-016 Console Server with PowerAlert product only) 1. Java Technology Restrictions. Licensee shall not create, modify, change the behavior of, or authorize licensees of Licensee to create, modify, or change the behavior of, classes, interfaces, or subpackages that are in any way identified as "java", "javax", "sun" or similar convention as specified by Sun in any naming convention designation. In the event that Licensee creates an additional API(s) which: (a) extends the functionality of a Java Environment; and (b) is exposed to third party software developers for the purpose of developing additional software which invokes such additional API, Licensee must promptly publish broadly an accurate specification for such API for free use by all developers. 2. Trademarks and Logos. This License does not authorize an end user licensee to use any Sun Microsystems, Inc. name, trademark, service mark, logo or icon. The end user licensee acknowledges that Sun owns the Java trademark and all Java-related trademarks, logos and icons including the Coffee Cup and Duke ("Java Marks") and agrees to: (a) comply with the Java Trademark Guidelines at http://java.sun.com/trademarks.html (b) not do anything harmful to or inconsistent with Sun's rights in the Java Marks; and (c) assist Sun in protecting those rights, including assigning to Sun any rights acquired by Licensee in any Java Mark.

Page 222 of the Tripp Lite B096-048 user manual — POWER & ENVIRONMENTAL MANAGEMENT
Page 222 · click to enlarge
Page 222
3. Source Code. Software may contain source code that, unless expressly licensed for other purposes, is provided solely for reference purposes pursuant to the terms of your license. Source code may not be redistributed unless expressly provided for in the terms of your license. 4. Third Party Code. Additional copyright notices and license terms applicable to portions of the Software are set forth in the THIRDPARTYLICENSEREADME.txt file.
Page 223 of the Tripp Lite B096-048 user manual — Appendix D Service and Warranty
Page 223 · click to enlarge
Page 223

Appendix D Service and Warranty

Limited Warranty Seller warrants this product, if used in accordance with all applicable instructions, to be free from original defects in material and workmanship for a period of 2 years (except U.S., Canada and Mexico: 1 year) from the date of initial purchase. If the product should prove defective in material or workmanship within that period, Seller will repair or replace the product, in its sole discretion. Service under this Warranty includes parts and Tripp Lite service center labor. On-site service plans are available from Tripp Lite through authorized service partners (in most areas). Contact Tripp Lite Customer Service at (773) 869-1234 for details. International customers should contact Tripp Lite support at intlservice@tripplite.com. THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM ACCIDENT, MISUSE, ABUSE OR NEGLECT. SELLER MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY EXPRESSLY SET FORTH HEREIN. EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ALL IMPLIED WARRANTIES, INCLUDING ALL WARRANTIES OF MERCHANTABILITY OR FITNESS, ARE LIMITED IN DURATION TO THE WARRANTY PERIOD SET FORTH ABOVE; AND THIS WARRANTY EXPRESSLY EXCLUDES ALL INCIDENTAL AND CONSEQUENTIAL DAMAGES. (Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. This Warranty gives you specific legal rights, and you may have other rights which vary from jurisdiction to jurisdiction).

Tripp Lite; 1111 W. 35th Street; Chicago IL 60609; USA

WARNING: The individual user should take care to determine prior to use whether this device is suitable, adequate or safe for the use intended. Since individual applications are subject to great variation, the manufacturer makes no representation or warranty as to the suitability or fitness of these devices for any specific application. Warranty Registration Visit www.tripplite.com/warranty today to register the warranty for your new Tripp Lite product. You’ll be automatically entered into a drawing for a chance to win a FREE Tripp Lite product!*

* No purchase necessary. Void where prohibited. Some restrictions apply. See website for details.

Page 224 of the Tripp Lite B096-048 user manual — 200903108 93-2879_EN
Page 224 · click to enlarge
Page 224

Tripp Lite World Headquarters 1111 W. 35th Street, Chicago, IL 60609 USA (773) 869-1234 (USA) • 773.869.1212 (International)

www.tripplite.com

200903108 93-2879_EN

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Tripp Lite B096-048

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.