EN
Tripp Lite logo
Official user manual

Tripp Lite B005-008

45 pages·1.3 MB·Switch·PDF·ENDEFRITNLJA
Tripp Lite B005-008
Table of Contents 23 sections 8 Port KVM Switch · Introduction · PC · Controls and Connections · … ShowHide
Page 1 of the Tripp Lite B005-008 user manual — 8 Port KVM Switch with On-Screen-Display (OSD) and Audio
Page 1 · click to enlarge
Page 1

Tripp Lite World Headquarters 1111 W. 35th Street, Chicago, IL 60609 USA (773) 869-1234, www.tripplite.com User’s Manual

8 Port KVM Switch with On-Screen-Display (OSD) and Audio

Model #: B005-008 NOTE: Follow these installation and operating procedures to ensure correct performance and to prevent damage to this unit or to its connected devices. Copyright © 2000 Tripp Lite. All rights reserved. All trademarks are the property of their respective owners. Technical specifications are subject to change without notice.

Page 2 of the Tripp Lite B005-008 user manual — Table of Contents:
Page 2 · click to enlarge
Page 2

Table of Contents:

Introduction Features Hardware Requirements Console PC Cables Controls and Connections Front View Rear View Installation First Station Installation Daisy Chaining Operation Hot Plugging Powering Off and Restarting Port Selection Port ID Numbering Numbering Rules Port Numbering Table Hot Key Operation Hot Key Navigation Hot Key Broadcasting Previous/Next Switching OSD Operation Navigation OSD Main Menu Headings The Function Keys OSD Security Features Password Lock/Unlock Console Appendix Station Numbering Table Troubleshooting Specifications FCC Radio / TV Interference Notice Lifetime Limited Warranty

Page 3 of the Tripp Lite B005-008 user manual — Introduction
Page 3 · click to enlarge
Page 3

Introduction This KVM Switch allows access to multiple PCs from a single console (keyboard, mouse, and monitor). Control up to 8 PCs or daisy chain as many as 32 of these units to control up to 256 PC’s from a single keyboard-monitor-mouse console. This 8-Port KVM Switch provides three convenient methods to access any PC connected to the system:

1. Using the port selection switches located on the front panel of the unit 2. Entering Hot Key combinations from the keyboard 3. Using the menu driven OSD (On Screen Display) feature. A powerful Quick View Scan Mode feature allows you to auto scan and monitor the activities of all operating PCs on the installation one by one.
Page 4 of the Tripp Lite B005-008 user manual — Introduction
Page 4 · click to enlarge
Page 4
  • Features:
  • Daisy Chain Up To 32 Additional Units - Control Up to 256 PCs From a Single Console
  • No Software Required - PC Selection via Front Panel Switches, Hot Key s, or OSD (On Screen Display)
  • Quick View Scan Mode for Monitoring Selected PCs
  • PS/2 and Serial Mouse Emulation Provided For System Bootup
  • Console’s PS/2 Mouse Controls All Connected PCs - Even Those With Serial Mice
  • Microsoft Intellimouse Pro, Logitech FirstMouse, MouseMan, IBM Scrollpoint Mouse Support
  • SVGA, VGA and Multisync Monitor Support
  • LED Display For Easy Status Monitoring
  • Rack Mountable in 19” System Rack
  • Audio Support Built In
  • Hot Pluggable - Add or Remove PCs for Maintenance Without Powering Down the Switch
  • Supports DDC2B.
Page 5 of the Tripp Lite B005-008 user manual — PC
Page 5 · click to enlarge
Page 5
  • Hardware Requirements: Console
  • A VGA, SVGA, or Multisync monitor capable of the highest resolution that you will be using on any of the PCs.
  • A PS/2 Style Mouse
  • A PS/2 Style Keyboard PC Each PC must have:
  • A VGA, SVGA or Multisync card.
  • Either a 6-pin mini-DIN (PS/2 style), or DB-9 (standard serial), mouse port.
  • Either a 6-pin mini-DIN (PS/2 Style) keyboard port with +5V DC on pin 4 and Ground on pin 3, or a 5-pin DIN (AT Style) keyboard port with +5V DC on pin 5 and ground on pin 4. Cables The following are the cables to connect your KVM Switch:

P762-006 AT Cable Kit – 6’ P762-010 AT Cable Kit – 10’ P764-006 PS/2 Cable Kit – 6’ P764-010 PS/2 Cable Kit – 10’ P766-006 Daisy Chain Cable – 6’

Page 6 of the Tripp Lite B005-008 user manual — Controls and Connections B005-008 Front View:
Page 6 · click to enlarge
Page 6

Controls and Connections B005-008 Front View:

Picture 1. Status LEDs: On Line: Lights ORANGE when the attached PC is ON. Selected: Lights GREEN to indicate which port is currently selected. 2. K/M Reset To reset the keyboard and mouse, press the Port1 / Port2 switch simultaneously for three seconds. 3. Port Selection Switches Press a switch to access the PC attached to the corresponding port. 4. Power LED Lights to indicate that the unit has been turned On and is receiving power. 2. Power Switch B005-008 Rear View:

Picture 1. Daisy Chain Section If you daisy chain units, the daisy-chain cables (P766-006) plug in here. 2. CPU Port Section The cables from the PCs plug in here. 3. Power Jack The power adapter plugs in here. 4. DIP Switch SW 1 - 5: Sets the Station No. (see the Station Numbering Table in the Appendix for details) SW 6: Enables/Disables OSD Hot Key switching (On = Enabled; Off = Disabled). 5. Link Link is reserved and has no function at this time. 6. Console Port Section Your monitor, keyboard and mouse plug in here. 7. Microphone and Speaker Jacks Your microphone and speakers plug in here.

Page 7 of the Tripp Lite B005-008 user manual — Picture
Page 7 · click to enlarge
Page 7

Installation: Make sure that power to all the devices (KVM Switch and PCs) you will be connecting up have been turned off. First Station Installation The First Station is the switch with the console. To install: 1. Set DIP Switches 1 - 5 on the back of the unit to ON. (see the Station Numbering Table in the Appendix for details). 2. To enable Hot Key port selection under OSD, set DIP Switch 6 to ON. (see Hot Key Operation section). 3. Plug the monitor, keyboard, and mouse into the Console port connectors on the rear of the Switch. 4. Use connector cable sets (listed in the Hardware Requirements section) to connect each PC’s monitor, keyboard and mouse ports to one of the KVM ports.

section).

Picture 5. Connect the power adapter; plug it in; and push the Power button on the KVM switch.

PatternIndication LED’s 1 – 4 Flash SimultaneouslyInternal RAM Memory Error LED’s 1 – 4 Flash One after the OtherExternal RAM Memory Error LED’s 1 & 2 and 3 & 4 Alternately FlashROM Test Error

If any of these problems occur, turn the Switch Off, then turn it On again.

6. Turn on the power to the PCs.

Note: The KVM Switch must be on b e f o re turning on the PCs. Daisy Chaining An additional 32 units can be daisy chained so that as many as 256 PCs can be controlled in a complete installation. The KVM Switch with the console is considered the First Station; the KVM Switch that daisy chains to it is considered the Second Station; the next in the chain is the Third Station, etc. To daisy chain, do the following: 1. All KVM Switches and PCs must be turned off – including preexisting devices on the installation . 2. Set DIP Switches 1 - 5 on the First Station to ON. (see the Station Numbering Table in the Appendix for details). 3. Set DIP Switches 1 - 5 on the Second Station. Repeat for subsequent stations. 4. Connect the Chain Out Port of each Switch to the Chain In Port of the next Switch downstream using a Daisy Chain cable set P766-006. Nothing must be connected to the Chain In Port of the First Station. 5. Connect a power adapter to each KVM switch and plug them in. 6. Connect the PCs to the ports with the cable sets described in Cables in the Hardware Requirements section. 7. Power up the system up by turning on the last KVM switch in the chain and working back to the First station. Turn on the PCs when all KVMs are ON.

Picture

Page 8 of the Tripp Lite B005-008 user manual — Operation
Page 8 · click to enlarge
Page 8
  • Operation Hot Plugging Components can be removed and added back into the installation by unplugging their cables from the unit’s ports without the need to shut the switch down. The following procedures must performed in order for hot plugging to work:
  • Hot Plugging CPU Ports: When hot plugging cables from the CPU ports: 1. The cable must be plugged back into the same port it was removed from, and the CPU must be OFF. 2. After plugging the cable back in, you must perform a K/M Reset on the First Stage unit by simultaneously pressing the Port1 / Port 2 switch combination for three seconds.
  • Hot Plugging Console Ports: When hot plugging the mouse from the KVM Switch’s console mouse port: 1. The mouse may be removed and replaced (to reset the mouse, for example), as long as it is the same mouse. 2. If you plug in a different mouse, all the stations and all the computers must be shut down for 10 seconds, then restarted according to the directions in Step 7 of the Daisy Chaining section, above. Powering Off and Restarting If it is necessary to Power Off one of the KVM Switches, do the following before starting it back up: 1. Shut down all the computers that are attached to it, as well as all the stations and all the computers that are daisy chained down from it (all the child stations and the computers attached to them). 2. Wait 10 seconds, then restart the KVM Switch, starting with the last station in the chain and working back to the station you originally shut down. 3. After the KVM Switches are up, power On the PCs, starting with the ones attached to the last station in the chain and working back to the station you originally shut down.

Port Selection Controlling all the PCs connected to the Switch is very easy. The following three methods can be used:. • Manual Simply press the appropriate port selection switch on the unit’s front panel. The Selected LED will light to indicate that the port is selected. The On Screen Display (see OSD section) automatically switches to highlight the PC selected.

  • Note: On a daisy chained installation, you must press the Port Selection switch on the KVM Switch that connects directly to the PC you want to access.
  • Hot Key Press [LCtrl+RCtrl] (simultaneously); key in the Port ID (see Port ID Numbering, below, for details); then press [Enter].
  • OSD Press either Left [Ctrl] or Right [Ctrl] twice to access the OSD Main Menu; Either:
  • Key in the Port ID (see Port ID Numbering, below for details); then press [Enter], or
  • Use the Arrow Keys or Mouse to move the Highlight Bar to the port you want; then press [Enter], or Double Click on it with the mouse.
Page 9 of the Tripp Lite B005-008 user manual — Port ID Numbering
Page 9 · click to enlarge
Page 9
  • Port ID Numbering Since each CPU Port on the installation is assigned a unique Port ID . You can directly access any computer on any level of the installation by specifying the Port ID using the Hot Key port selection method, or from the OSD Main Menu. The Port ID is made up of two parts: 1. The Station Number - a two digit number which reflects the KVM Switch’s position in the daisy chain sequence; 2. The Port Number - a one or two digit number which reflects the port on the Switch. Numbering Rules The rules for assigning Station and Port numbers are as follows:
  • The Station Number precedes the Port Number and must always be two digits. That means that Stations 1 - 9 must be padded with a preceding zero, so their Stations Numbers will be 01 - 09.
  • The Port Number can be either one or two digits long. Ports 19 can be keyed in as 01 - 09, or 1 - 9 according to your preference. For example, after enabling Hot Key switching with [Ctrl+Ctrl] (pressing and releasing both Ctrl keys simultaneously), or invoking the OSD Main Menu with [Ctrl]+[Ctrl] (pressing and releasing either Ctrl key twice), keying in:

0308 [Enter] switches to the PC attached to CPU Port 8 of KVM Station 3. Likewise:

123 [Enter] switches to the PC attached to CPU Port 3 of KVM Station 12. You may also specify a partial Port ID by keying in only one or two digits, in which case the digits specify the Port ID of the Station that is currently accessed. As in:

3 [Enter] which switches to the PC attached to CPU Port 3 of the KVM Station that is already being accessed. Port Numbering Table Port Numbering is summarized in the following table:

Number of DigitsMeaning 4First two for Station Number, Second two for Port Number 3First two for Station Number, Third for Port Number 1 or 2Port Number on the Current Active Station
Page 10 of the Tripp Lite B005-008 user manual — Hot Key Operation
Page 10 · click to enlarge
Page 10

Hot Key Operation Hot Key Navigation Hot Key navigation allows you to access connected PCs directly from the keyboard.

To select a port with the Hot Key method, do the following: 1. Press and release both the left and right Ctrl Keys [Ctrl+Ctrl] at the same time.

  • 2. Key in the Port ID for the PC you want to access (see Port ID Numberin g, above, for details), then press [Enter]. The On Screen Display (see OSD section) automatically switches to highlight the PC that you have selected. When you key in the Port ID, note the following:
  • You must key in the Port ID and press [Enter] within six seconds of releasing the [Ctrl+Ctrl] combination.
  • Number keys must be pressed from the regular keyboard; not from the numeric keypad.
  • The keys must be pressed and released one key at a time. Hot Key Broadcasting Commands can be broadcast to all PCs from the console’s keyboard with the following Hot Key combinations:
  • [Ctrl] + [Alt] + [1] + [Enter] - to initiate the keyboard broadcast A Broadcast symbol appears in front of the Station ID (if the Port ID is currently displayed on the screen), while in Broadcast mode.
  • [Ctrl] + [Alt] + [2] + [Enter] - to end the keyboard broadcast When keying in the combination:
  • Number keys must be pressed from the regular keyboard; not from the numeric keypad.
  • The keys must be pressed and released one key at a time.
  • The interval between key presses cannot be longer than 6 seconds.
  • If you make a mistake, just start over again with [Ctrl] + [Alt] + [1] + [Enter].
  • Confirmation that the key in has been accepted is made either by OSD or with one or two beeps. Previous/Next Switching Previous/Next switching enables you to quickly switch from the currently active computer to the previous or next available computer in the installation. To invoke, key in the following Hot Key combination: 1. Press and release [Ctrl]+[Alt]+[9]+[Right Shift] to Switch to the Next available computer. 2. Press and release [Ctrl]+[Alt]+[9]+[Left Shift] to switch to the first available computer that resides on the installation Previous to the current one. Switching is cyclical. If you are currently at Port 8 of the last station and use the key combination to switch to the Next available computer, you will circle back to the first computer in Station 1, and vice versa when switching backwards to an available computer that exists prior to the current one.
Page 11 of the Tripp Lite B005-008 user manual — 01-06 + NET ADMINIT 01-07 + FILE SERVER 1
Page 11 · click to enlarge
Page 11

OSD Operation On Screen Display (OSD), provides a menu driven interface to handle the PC switching procedure. While Hot Key switching still works, using OSD is a great deal more convenient - especially in large, daisy chained installations. All operations start from the OSD Main Menu. To pop up the Main Menu, tap either of the Ctrl keys twice:

Tripp Lite B005-008 — OSD Operation diagram (page 11)
Fig. 1 · OSD Operation
ListAll SNPN QV PC NAME 01-01 + ADMINST

01-06 + NET ADMINIT 01-07 + FILE SERVER 1

  • F1 F2 F3 F4 F5 F6 GOTO SCAN LIST QVSW EDIT SET
  • OSD always starts in List view, with the highlight bar at the same position it was in the last time it was closed.
  • From the Main Menu, you can go directly to any port by either keying in its Port ID (Station Number - Port Number), and pressing [Enter], or by double clicking on it with the mouse. Navigation
  • To dismiss the menu, and deactivate OSD, press [Esc]
  • Use the Up and Down Arrow Keys to move up or down through the list one line at a time
  • Use [Pg Up] and [Pg Dn] to move up or down through the list one screen at a time
  • Click on to move up or down through the list one line at a time
  • Click on to move up or down through the list one screen at a time
  • To activate a port, move the Highlight Bar to it then press [Enter] or Double Click with the left mouse button. OSD Main Menu Headings:
SN-PNLists the Port ID numbers (Station Number – Port Number) for all the CPU Ports on the installation. To access a particular PC, use the Navigation Keys or the Mouse to move the Highlight Bar to the desired location and then press [Enter]. QVPorts that have been selected for Quick View Scan Mode (see F2 and F4 below) are identified by an arrowhead in this column. PCLists all the PCs that are Powered On and are On Line. NameIf a port has been given a name (see F5 below), the name appears in this column.
Tripp Lite B005-008 — 01-06 + NET ADMINIT 01-07 + FILE SERVER 1 diagram (page 11)
Fig. 2

list only displays those ports whose names begin with “a”. If the next letter you type is “b”, the list is further narrowed down to only those ports whose names begin with ab, etc.

To return to the OSD Main Menu without making a choice, press [Esc].

Page 12 of the Tripp Lite B005-008 user manual — OSD Operation
Page 12 · click to enlarge
Page 12
  • F2 Scan: Pressing [F2] initiates the Quick View Scan Mod e, in which the OSD cycles through all the ports that have been selected for Quick View Scanning (see F4, below), and displays each one for the amount of time set with the Set Scan Duration function (see F6, below). When you want to stop at a particular location, press any key to stop scanning.

screen will be blank, and the mouse and keyboard will have no effect. To recover, key in the Hot Key sequence (see Hot Key Selection, above), for any Port ID that has an active PC attached. (2) As the OSD cycles through the selected ports, an S appears in front of the Port ID display as each computer is

accessed to indicate that the computer is being accessed under Quick View Scan Mode.

  • F3 List: Pressing [F3] brings up a submenu that lets you control the ports which the OSD lists:
ChoiceMeaning AllLists the Port ID Numbers and Names (if names have been specified, see F5) of all the ports in the installation. QView OnlyLists only the ports that have been selected for Quick View scanning (see F4 below). QView or PoweredLists only the ports that either have been selected for Quick View scanning (see F4 below) or have their attached PC Powered On. QView and NameLists only the ports that have been selected for scanning under Quick View Scan Mode (see F4 below), and have been assigned names (see F5 below). Name OnlyLists only the ports that have been assigned names (see F5 below).

then pressing [Enter] or Double Clicking with the left mouse button. (2) If you select a port that does not have a PC attached to it, or if the attached PC is powered Off, the OSD will

still switch to it, and will not show an error. • F4 QVSW: Broaden or narrow the number of ports that get scanned by using the QVSW (Quick View Scan Switch) function. [F4] is a toggle that selects or deselects the currently highlighted port for the Quick View Scan Mode function (see F2, above). To select/deselect a port for QVSM:

1. Use the Up and Down Arrow Keys or Mouse to move the highlight bar to the port. 2. Press [F4].
  • An arrowhead in the QV column indicates when a port has been selected for Quick View Scanning.
  • F5 Name: Every port can be named. The Name function allows you to name (or rename) the currently highlighted CPU Port. To edit a Port Name: 1. Use the Navigation Keys or Mouse to move the highlight bar to the port you want (you can use the F3 List function to broaden or narrow the port selection list). 2. Press [F5]. 3. Key in the new Port Name. The maximum number of characters allowed is 15. Legal characters include:
  • All alpha characters: a - z; A - Z
  • All numeric characters: 0 - 9
  • +, -, /, :, ., and Space

Case does not matter; OSD displays the Port Name in all capitals no matter how they were keyed in.

4. Press [Enter] to have the change take effect or press [Esc] to abort. • F6 Set [F6] allows you to configure the OSD settings. To change a setting, use the Up and Down Arrow Keys or mouse to move the highlight bar to it, then press [Enter] or Double Click the left mouse button. Selecting Port ID Display Duration, Port ID Display Position, Port ID Display Mode, and Scan Duration brings up submenus of their own with choices for you to select. Move the Highlight Bar to the choice you want, then press

Page 13 of the Tripp Lite B005-008 user manual — OSD Operation
Page 13 · click to enlarge
Page 13

[Enter] or Double Click the left mouse button. An icon appears before the choice to indicate that it is the currently selected one. The settings are explained in the table below:

Setting Function Port ID Display Duration Determines how long a Port ID is displayed. There are two choices: 3 seconds Port ID Display Position Allows you to position for the Port ID on the screen. After you highlight this item and press [Enter], the menu disappears and the port ID is displayed. Use the arrow keys or the mouse to position the port ID display then press [Enter] or Double Click the Left Mouse Button to lock the position and return to the Set Submenu. Port ID Display Mode Selects how the Port ID is displayed. There are three choices: Number plus the Name, Number alone or Name alone. Scan Duration Determines how long the display dwells on each Port when it cycles through the selected Ports in the Quick View Scan Mode. The available options are: 3, 5,10, 15, 20, 30, 40 and 60 seconds. Clear Name List Clears all the Port Names from the Name List. You will be asked to Confirm before the procedure takes place. A message will be displayed while the Names are being cleared. Once the Names have been cleared, a message will appear indicating that the procedure was completed successfully. Restore Default Values Clears all the Settings from the memory and returns the unit to the factory settings. You will be asked to Confirm before the procedure takes place. A message will be displayed while the Settings are being cleared. Once the Settings have been cleared, a message will appear indicating that the procedure was completed successfully. When you have finished making your selections, press [Esc] to return to the OSD Main Menu. Factory Default Settings: The factory default settings are as follows:

Setting Default Port ID Display Duration Always On Port ID Display Mode The Port Number plus the Port Name Scan Duration 5 Seconds

Page 14 of the Tripp Lite B005-008 user manual — OSD Security Features
Page 14 · click to enlarge
Page 14

OSD Security Features

Tripp Lite B005-008 — OSD Security Features diagram (page 14)
Fig. 3 · OSD Security Features

UP DOWN EXIT ACCEPT MORE In order to prevent unauthorized access to the computers, OSD provides two security features: Password and Lock/Unlock Console. If a password is set, the console can only be locked/unlocked by first specifying the password. When the console is locked, only the current monitor screen displays. Attempts to input information from the console will have no effect. Attempts to switch to a different port, either by console or by pressing the manual switches will have no effect either. The only way to gain access to the computers is by unlocking the console. Password: To set a password: 1. Highlight this item, then press [Enter}. You are presented with a screen that allows you to key in your password. The password may be up to 15 characters long and can consist of any combination of numbers and letters (A to Z and 0 to 9). 2. Key in the new password, then press [Enter]. You will be asked to key the password in again, in order to confirm that it is correct. 3. Key in the new password again, then press [Enter]. If the two entries match, the new password is accepted and the screen displays the following message: ‘PASSWORD SET OK’. If the entries do not match, the screen displays the message ‘INVALID PASSWORD’ in which case you must start again from the beginning. Note: To modify or delete a previous password, use the backspace key to erase the individual letters or numbers, or,

with the cursor at the beginning of the password, press the [Spacebar] to erase the entire password at once. Lock/Unlock Console: To lock/unlock the console: 1. Highlight this item, then press [Enter]. 2. If no password has been set, the system locks the console (if it is unlocked), or unlocks the console (if it is locked). To acknowledge the change, the buzzer sounds three times, and one of the following messages displays on the screen for three seconds: LOCK OK (if the console has been locked) or UNLOCK OK (if the console has been unlocked). 3. If a password has been set (see above), a password entry screen appears. Key in the password, then press [Enter]. If the password is correct, the system locks/unlocks the console as in step 2. If the password is incorrect, the message ‘INVALID PASSWORD’ displays for three seconds, after which it disappears and you can try again. Note: To indicate that the console has been locked, the following symbol appears in front of the PORT ID DISPLAY

on the monitor[ z z Z ]
Page 15 of the Tripp Lite B005-008 user manual — Appendix
Page 15 · click to enlarge
Page 15

Appendix Station Numbering Table The first B005-008 KVM Switch (the one connected to the console), is considered the First Station; the B005-008 KVM Switch that daisy chains to it is considered the Second Station; the B005-008 KVM Switch daisy chained to the Second Station is considered the Third Station, etc. Switches 1 - 5 of the DIP Switch located on the switch’s rear panel are used to set the Station Number of each daisy chained unit, as indicated in the table below (0 = ON; 1 = OFF):

Station SW1 SW2 SW3 SW4 SW5 1 ON 2 OFF ON 3 ON OFF ON ON ON 4 OFF OFF ON ON ON 5 ON ON OFF ON ON 6 OFF ON OFF ON ON 7 ON OFF OFF ON ON 8 OFF OFF OFF ON ON 9 ON ON ON OFF ON 10 OFF ON ON OFF ON 11 ON OFF ON OFF ON 12 OFF OFF ON OFF ON 13 ON ON OFF OFF ON 14 OFF ON OFF OFF ON 15 ON OFF OFF OFF ON 16 OFF ON 17 ON OFF 18 OFF ON ON ON OFF 19 ON OFF ON ON OFF 20 OFF OFF ON ON OFF 21 ON ON OFF ON OFF 22 OFF ON OFF ON OFF 23 ON OFF OFF ON OFF 24 OFF OFF OFF ON OFF 25 ON ON ON OFF OFF 26 OFF ON ON OFF OFF 27 ON OFF ON OFF OFF 28 OFF OFF ON OFF OFF 29 ON ON OFF OFF OFF 30 OFF ON OFF OFF OFF 31 ON OFF 32 OFF

Page 16 of the Tripp Lite B005-008 user manual — See Installation section for more information.
Page 16 · click to enlarge
Page 16

Troubleshooting Symptom Possible Cause Action Hot Keys do not get a response under OSD

DIP Switch settings Make sure that DIP Switch 6 is set to ON.

Pressing the Hot Keys does not get a response

The connection from the selected port to the target PC has been broken or the PC is turned OFF.

Check the Online LED for the selected port. If it is not lit,: 1. Manually press one of the Select switches to connect to a PC that is powered ON. 2. Check the cables to make sure all are properly connected. 3. If the desired PC is OFF, power it ON. Improper keyboard reset

Reset the keyboard and mouse by simultaneously pressing and holding the Select Switches 1 and 2 on the First Stage KVM unit for three seconds. Do as often as necessary. Unplug the keyboard connector from the Console Keyboard Port, then plug it back in. Improper KVM switch reset

Turn off all PCs connected to the switch. Wait five seconds before turning them back on. Note: If a PC uses a mouse protocol sensitive operating system (such as NT), it may be necessary to restart it after turning the units back on.

1. Be sure to release both the [Ctrl] keys simultaneously. 2. After the [Ctrl] + [Ctrl] combination, be sure to key in the Port ID and press [Enter] within 6 seconds. Mouse is not responding

Incorrect keying in the Port ID.

Reset the keyboard and mouse by simultaneously pressing and holding the Select Switches 1 and 2 on the First Stage KVM unit for three seconds. Do as often as necessary. Port LED’s 1-4 flash repeatedly.

Improper mouse reset.

Power On Self Test problem

See Installation section for more information.

Power Consumption DC9V 600mA PC Connections Direct 8 Max. (via Daisy Chain) 256 Port Selection Front Panel Switches Hot Keys On Screen Display (OSD) Power 1 On Line 8 LED’s

1 x mini-DIN 6 Female (PS/2 Style Mouse) 1 x mini-DIN 6 Female (PS/2 Style Keyboard) 1 HDDB15 Female (standard VGA/SVGA) 2 x 3.5mm Earphone Jacks (Mic and Speaker) CPU Ports 8 x DB25 Female

Daisy Chain Ports DB25 Female (Daisy Chain In), DB25 Male (Daisy Chain Out) Scan Interval (OSD Selection) 3, 5, 10, 15, 20, 30, 40, 60 seconds Operating Temperature 41 – 104 F Storage Temperature -4 – 140 F Humidity 0 – 80%RH, Noncondensing Enclosure Metal Weight 6.25 lbs Dimensions 18” x 6” x 1¾” (19” 1U)

Specifications · Selected 8 Console · Connectors

Page 17 of the Tripp Lite B005-008 user manual — FCC Radio / TV Interference Notice
Page 17 · click to enlarge
Page 17

FCC Radio / TV Interference Notice Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. The user must use shielded cables and connectors with this product. Any changes or modifications to this product not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 1-YEAR LIMITED WARRANTY TRIPP LITE warrants its products to be free from defects in materials and workmanship for a period of one (1) year from the date of initial purchase. TRIPP LITE’s obligation under this warranty is limited to repairing or replacing (at its sole option) any such defective products. To obtain service under this warranty, you must obtain a Returned Material Authorization (RMA) number from TRIPP LITE or an authorized TRIPP LITE service center. Products must be returned to TRIPP LITE or an authorized TRIPP LITE service center with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase. This warranty does not apply to equipment which has been damaged by accident, negligence or misapplication or has been altered or modified in any way.

EXCEPT AS PROVIDED HEREIN, TRIPP LITE MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Some states do not permit limitation or exclusion of implied warranties; therefore, the aforesaid limitation(s) or exclusion(s) may not apply to the purchaser.

EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL TRIPP LITE BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Specifically, TRIPP LITE is not liable for any costs, such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, costs of substitutes, claims by third parties, or otherwise.

The policy of TRIPP LITE is one of continuous improvement. Specifications are subject to change without notice.

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Hot Keys do not get a response under OSDDIP Switch settingsMake sure that DIP Switch 6 is set to ON. p.16
Pressing the Hot Keys does not get a responseThe connection from the selected port to the target PC has been broken or the PC is turned OFF.Check the Online LED for the selected port. If it is not lit,: 1. Manually press one of the Select switches to connect to a PC that is powered ON. 2. Check the cables to make sure all are properly connected. 3. If the desired PC is OFF, power it ON. p.16
Pressing the Hot Keys does not get a responseImproper keyboard resetReset the keyboard and mouse by simultaneously pressing and holding the Select Switches 1 and 2 on the First Stage KVM unit for three seconds. Do as often as necessary. Unplug the keyboard connector from the Console Keyboard Port, then plug it back in. p.16
Pressing the Hot Keys does not get a responseImproper KVM switch resetTurn off all PCs connected to the switch. Wait five seconds before turning them back on. Note: If a PC uses a mouse protocol sensitive operating system (such as NT), it may be necessary to restart it after turning the units back on. p.16
Pressing the Hot Keys does not get a responseIncorrect keying in the Port ID.1. Be sure to release both the [Ctrl] keys simultaneously. 2. After the [Ctrl] + [Ctrl] combination, be sure to key in the Port ID and press [Enter] within 6 seconds. p.16
Mouse is not respondingImproper mouse reset.Reset the keyboard and mouse by simultaneously pressing and holding the Select Switches 1 and 2 on the First Stage KVM unit for three seconds. Do as often as necessary. p.16
Port LED’s 1-4 flash repeatedly.Power On Self Test problemSee Installation section for more information. p.16

Ask about the Tripp Lite B005-008

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Tripp Lite B005-008

Be the first to ask — other owners or our team will answer.

Original document

Tripp Lite B005-008 manual PDF

45 pages·1.3 MB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…