1111 W. 35th Street, Chicago, IL 60609 USA www.tripplite.com/support
Copyright ©2012 Tripp Lite. All rights reserved.







Thank you for buying the Smart CAT5 Switch system. This system is produced by Minicom Advanced Systems Limited.
Technical precautions This equipment generates radio frequency energy and if not installed in accordance with the manufacturer’s instructions, may cause radio frequency interference. This equipment complies with Part 15, Subpart J of the FCC rules for a Class A computing device. This equipment also complies with the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of Communications. These above rules are designed to provide reasonable protection against such interference when operating the equipment in a commercial environment. If operation of this equipment in a residential area causes radio frequency interference, the user, and not Minicom Advanced Systems Limited, will be responsible. Changes or modifications made to this equipment not expressly approved by Minicom Advanced Systems Limited could void the user’s authority to operate the equipment. Minicom Advanced Systems Limited assumes no responsibility for any errors that appear in this document. Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of Minicom Advanced Systems Limited. Trademarks PS/2 is a registered trademark of International Business Machines Corporation. All other trademarks and registered trademarks are the property of their respective owners.

Access and control multiple multi-platform computers from one Keyboard Video Mouse (KVM) console with the Smart CAT5 Switch (Smart CAT5) system. The Smart CAT5 comes in 108 and 116 models. Connect up to 8 computers to the 108 model, and up to 16 to the 116 model.
The Smart CAT5 is based on Minicom’s innovative ROC technology in which each computer/ server is directly connected to the switch via RIC on Cable (ROC) using standard CAT5 cable at a distance of up to 30m/99ft in a star configuration. The system also works with Minicom’s RICCs using standard CAT5 cable up to 10m/33ft. The system can contain a mixture of ROCS and RICCs. No external power is needed at the remote ROC/RICCs.
Hot-Swap - disconnect and reconnect computers without rebooting
Scan-mode operation with variable time interval
Operate the system using an On Screen Display (OSD) or Control software or front panel push buttons or keyboard hotkeys
Create multi-level cascade arrangements. For example by cascading the Smart CAT5 116, connect up to up to 256 computers in the system
The computers can be placed up to 10m/33ft from the Smart CAT5
Multi-platform — supports PS/2, SUN, and USB computers/servers
The Smart CAT5 system consists of:
Smart CAT5 Switch 108 or 116
Remote Interface Connection cables (RICCs) – PS/2, SUN, USB
RICC on Cable (ROCs) - PS/2, USB
CAT5 cables (1.5m provided)
Rack mounts for the Smart CAT5 and the ROC/RICCs
1U Rack mountable · RS232 Serial cable

The Smart CAT5 is compatible with:
PS/2, SUN and USB computers/servers
VGA, SVGA, or XGA monitors
DOS, Windows, LINUX, UNIX, MAC and all other major operating systems
Figure 1 illustrates the basic configuration of the Smart CAT5 system.

10 11 12 13 14 15 16 9 COMPUTER www.minicom.com
POWER 100-240 VAC 50/60 Hz 1 2 3 4 5 6 7 8
h p w o r ksta tion b 2 6 0 0
h p w o r ksta tion b 2 6 0 0
h p w o r ksta tion b 2 6 0 0
h p w o r ksta tion b 2 6 0 0
h p w o r ksta tion b 2 6 0 0
h p w o r ksta tion b 2 6 0 0
h p w o r ksta tion b 2 6 0 0
Figure 1 Smart CAT5 system configuration

Figure 2 illustrates the front panel of the Smart CAT5 116 model. The 108 model is the same but with only 8 columns of LEDs.

10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9
Figure 2 Smart CAT5 116 front panel
The figure below illustrates the rear panel of the Smart CAT5 116 unit. The 108 model is the same but with only 8 Computer ports.

10 11 12 13 14 15 16 9 COMPUTER www.minicom.com
POWER 100-240 VAC 50/60 Hz 1 2 3 4 5 6 7 8
Figure 3 Smart CAT5 116 rear panel
Switch off all computers
Place cables away from fluorescent lights, air conditioners, and machines that are likely to generate electrical noise
Ensure that the maximum distance between each computer and the Smart CAT5, does not exceed 10m/33ft

Each computer/ server is directly connected to the Smart CAT5 via the appropriate ROC or RICC using CAT5 cable in a star configuration. The system can contain a mixture of RoCs and RICCs. No external power is needed at the remote ROC/RICCs. The ROC/RICCs draw their power from the computer’s keyboard port (ROC/RICC PS/2, SUN) or from the USB port (ROC/RICC USB). The figures below illustrate the ROC PS/2 and ROC USB.

To computer’s Video card
To computer’s keyboard port
To computer’s mouse port
Figure 4 ROC PS/2

To computer’s Video Card
To computer’s USB Port
Figure 5 ROC USB (SUN)
The connections for ROC/RICC PS/2 are exactly the same. Figure 6 illustrates the RICC PS/2.
You can connect the ROC/RICC PS/2 to a powered on computer, but it must be in the following order:
Failure to connect in the above order while the server is running, may lead to the mouse malfunctioning until the server is rebooted.


Figure 6 RICC PS/2 connections
The ROC/RICC USB supports Windows 98 SE and later, MAC, SUN, SGI and all modern Linux distributions. The connections for ROC/RICC USB are exactly the same. Figure 7 illustrates the RICC USB and its connections.
To connect the ROC/RICC USB:

CAT5 cable to Smart CAT5 Computer port
Figure 7 RICC USB

Figure 8 illustrates the RICC SUN and its connections.
To connect the RICC SUN:

CAT5 cable to Smart CAT5 Computer port
Figure 8 RICC SUN
To connect a KVM console to the Smart CAT5:

3.6.1 Avoiding general rack mounting problems
Elevated operating ambient temperature
The operating ambient temperature of the rack environment may be greater than the room ambient when installing into a closed or multi-unit rack assembly. So install the equipment in an environment compatible with the maximum rated ambient temperature.
Install the equipment in a rack in such a way that the amount of airflow required for safe operation is not compromised.
Mount the equipment in the rack in such a way that a hazardous condition is not achieved due to uneven mechanical loading.
When connecting the equipment to the supply circuit, consider the effect that overloading of circuits might have on over-current protection and supply wiring.
Reliable earthing of rack-mounted equipment should be maintained. Give attention to supply connections other than direct connections to the branch circuit (e.g. use of power strips).
3.6.2 Rack mounting the Smart CAT5 The Smart CAT5 comes with screw holes on the side for easy rack mounting, see figure below.

Screw holes for bracket
Figure 9 Screw holes for rack mounting
Use the L-shaped brackets and screws provided to mount the Smart CAT5 on a server rack as illustrated below. The length of the screws used for connecting the brackets to the Smart CAT5 unit must not exceed 5 mm.
Reduced airflow · Mechanical loading · Circuit overloading


Screw the bracket into the side of the unit
Screw to the rack here
Figure 10 Connecting the L-shaped bracket
3.6.3 Rack mounting the RICCs You can attach the RICCs to a server rack or computer using the Velcro strips provided. Or connect it using the bracket provided.
The figure below illustrates the bracket.
Insert screws through bracket and into the rack
Insert screw through bracket and into the back of a computer
Insert screws through bracket and into the back of the RICC
Insert screws through bracket and into the back of the RICC

Figure 11 Rack mounting the RICC
3.6.4 Cascading Smart CAT5 switches
You can cascade the Smart CAT5 system. You do so by connecting the lower level Smart CAT5 Switches to ROC/RICCs. Follow the connections as illustrated in the figure below.

With the Smart CAT5 116 model, connect up to up to 256 computers through cascading.
A lower level Switch must have a different hotkey to display its OSD than a higher level switch. Changing the OSD display hotkey is explained on page 18 below.

10 11 12 13 14 15 16 9 COMPUTER
POWER 100-250 VAC 50/60 Hz 1 2 3 4 5 6 7 8
10 11 12 13 14 15 16 9 COMPUTER
POWER 100-250 VAC 50/60 Hz 1 2 3 4 5 6 7 8
10 11 12 13 14 15 16 9 COMPUTER
POWER 100-250 VAC 50/60 Hz 1 2 3 4 5 6 7 8
Figure 12 Cascading Smart CAT5 switches

Switch between the connected computers by either
The front panel Select buttons
The OSD (On Screen Display) or Control software
The OSD is also the place to adjust various settings as explained below.
When switching computers the illuminated LED of the top bank indicates which computer is currently selected.
To switch to the next computer forwards press Shift then, +. Release Shift, before pressing +.
To switch to the next computer backwards press Shift then, -. Release Shift, before pressing -.
To display the OSD:
Press Shift twice. The OSD Main window appears. See Figure 13. Lines with yellow text show active computers. Lines with blue text show inactive computers.
The Type column indicates whether a computer “C” or another switch “S” is connected to the port.
Keyboard hotkeys


Port number appears here
Figure 13 OSD Main window
4.2.1 Navigating the OSD
To navigate up and down use the Up and Down arrow keys.
To jump from one column to the next (when relevant) use the Tab key.
To exit the OSD or return to a previous window within the OSD press Esc.
4.2.2 Selecting a computer
To select a computer:
Or, type the port number of the desired computer.
4.2.3 The OSD settings (F2) Press F2. The OSD Settings window appears see Figure 14.
C=Computer · Instruction keys


Figure 14 Settings window
4.2.4 The General settings
With the GENERAL line highlighted, press Enter. The General settings window appears see Figure 15.

Figure 15 General Settings window
From this window you can do the following:
4.2.4.1 Security The OSD comes with an advanced password security system that contains 3 different security levels. Each security level has different access rights to the system.
These levels are as follows:

4.2.4.2 Administrator (Status A) The Administrator can:
Set and modify all Passwords and security profiles
Fully access any computer
Use all OSD functions
4.2.4.3 Supervisor (Status S) The Supervisor can:
Fully access any computer
Access the following OSD functions only –F4 Scan, F5 Tune and F6 Moving the Confirmation label.
4.2.4.4 User (Status U) There are 6 different Users in the Smart CAT5 system. Each User has a Profile set by the Administrator that defines the access level to different computers. There are 3 different access levels; these are explained on page 21.
4.2.4.5 Activating password protection By default OSD access is not password protected. Only the Administrator can password-protect the OSD or disable password protection.
To do so:
If you forget the Administrator's password, go to www.minicom.com. From the Support menu select Smart Switches. There you will find information that explains how to restore a lost password or reset the switch to its default settings including the default password.

4.2.4.6 Displaying the OSD of cascaded switches When you have cascaded Smart CAT5 switches, a lower level Switch must have a different OSD display hotkey than a higher level switch. (See page 12.)
The hotkeys can be any of the following:
To change the top level hotkey:
To change a lower level hotkey:
4.2.4.7 Autoskip When Autoskip is on, you can only access the active computers. When Autoskip is off, you can access active and inactive computers. (This includes operating the Switch via the OSD, front panel buttons or hotkeys).
To change the Autoskip setting:
4.2.4.8 Serial port The Serial port is used for the Control Management program. Serial port On means the program can be used.

To change the Serial port setting:
4.2.4.9 Changing the Keyboard language In the OSD the names of the computers can be written in 3 different languages – English (EN), German (DE), and French (FR). The keyboard is preset to English; this can be changed as follows:
4.2.4.10 Editing the Switch name You can substitute up to 18 characters in the line. A space constitutes a character. When there is more than one switch in the system give each Switch’s OSD a different name.
4.2.5 F7 Defaults
Press F7 to return the OSD to the factory default settings. Note! All changes made will be removed.
4.2.6 The Ports settings
From the General Settings, return to the Settings window by pressing Esc. Navigate to the Ports line and press Enter. The Ports settings window appears see Figure 16.

Figure 16 Ports Settings window

4.2.6.1 Editing the computer name
In this window you can edit the computer names with up to 15 characters. When you have a cascaded CAT5 KVM Switch connected to a Computer port give the switch a distinct name. See Figure 16.
To erase a character:
Select it and press the Spacebar. Blank spaces remain in place of the erased character.
To erase an entire line:
Place the cursor at the beginning of the line. Keep the Spacebar depressed until the line is erased.
4.2.6.2 Keyboard (KB) By default the Keyboard mode is set to PS, which is suitable for Windows, Linux, MAC OS, SUN Solaris and most other operating systems.
For certain UNIX operating systems set the KB column as follows:
U1 for HP UX
U2 for Alpha UNIX, SGI, Open VMS
U3 for IBM AIX
4.2.6.3 (HKEY) hotkey - Cascading When there are cascaded switches, and the lower level Switch has had its OSD display hotkey changed, you must do the following:
Adjust the HKEY setting in the Ports Settings window of the higher level switch to reflect the lower level switch’s new hotkey.
To reflect the new hotkey:
4.2.7 The Time settings
In the Settings window navigate to the Time line and press Enter. The Time settings window appears see Figure 17.


Figure 17 Time settings window
4.2.7.1 Scan (SCN) - Label (LBL) - Time out (T/O) SCN - In the SCN column, change the scan period.
LBL - In the LBL column, change the display period of the OSD label showing which computer is currently accessed.
T/O - When password protection is activated you can automatically disable the Management keyboard, mouse and screen after a preset time of non-use. Set this Timeout period in the T/O column.
To set the above periods:
Typing 999 in the LBL column displays the label continuously. Typing 000 – the label will not appear.
Typing 999 in the T/O column disables the Timeout function. Warning! Typing 000 causes the Timeout function to work immediately. Minimum time should be not less than 005 seconds.
Typing 999 in the SCN column displays the screen for 999 seconds. Typing 000 – the computer screen is skipped.
4.2.8 Users
In the Settings window navigate to the Users line and press Enter. (Note! Users is only enabled if the security status is set to On, see page 17). The Users settings window appears see Figure 18.


Figure 18 Users settings window
There are 3 different access levels. These are:
Y – Full access to a particular computer. Plus access to the F4, F5 and F6 OSD functions
V –Viewing access only, to a particular computer (No keyboard/mouse functionality)
N – No access to a particular computer – A TIMEOUT label appears if access is attempted
To give each user the desired access level:
4.2.9 Security
In the Settings window navigate to the Security line and press Enter. The Security settings window appears see Figure 19.


Figure 19 Security settings window
The ‘T’ column on the right hand side stands for Type of password.
There can only be 1 Administrator password, 1 Supervisor password, and 6 User passwords.
To change a user name or password:
By default the User Profile settings are full access.
4.2.10 The OSD HELP window – F1
To access the HELP window press F1. The HELP window appears see Figure 20.

Figure 20 HELP window
Please note! All the functions set out in the Help window are performed from the Main window. The Help window is merely a reminder of the hotkeys and their functions.

4.2.11 Scanning computers– F4
Where necessary adjust the scan time in the Time Settings window, see above.
To activate scanning:
To deactivate scanning:
Press F4.
4.2.12 Tuning – F5
You can tune the image of any remote computer screen from the Select Computer window.
To adjust the screen image:
4.2.13 Moving the label – F6
Position the OSD label anywhere on the screen.
To position the label from the Main window:
4.2.14 Sending monitor emulation information to ROC/RICCs – F10
Display Data Channel (DDC) is a VESA standard for communication between a monitor and a video adapter.

Input the DDC information of the monitor connected to the Smart CAT5 switch into the memories of all connected ROC/RICCs when first installing system.
To input the DDC information:
4.2.14.1 Updating the DDC information Update the DDC information in any of the following circumstances:
When replacing the monitor connected to Smart CAT5 Switch
When adding a new ROC/RICC to the system
When reconnecting an existing ROC/RICC that was temporarily used in a different system
To update the DDC information, repeat the steps as set out above.

As an alternative to the OSD, you can operate the system with the Control software located on our website www.minicom.com in the Support section on the Smart CAT5 Switch Upgrades page. With the OSD you operate the system and view the computer screens on the same monitor. The Control software requires 2 monitors: 1 for the software and 1 to view the computer screens.
With the Control software you can:
Save configurations for future use
Read configurations from and write configurations to the Smart CAT5 Switch
Pentium 166 or higher computer
Windows 98 and later
To run the software, connect the RS232 Serial cable to the computer containing the software, and to the Smart CAT5. See the figure below.

10 11 12 13 14 15 16 9 COMPUTER www.minicom.com
POWER 100-240 VAC 50/60 Hz 1 2 3 4 5 6 7 8
Control software installed here
Figure 21 Connecting the RS232 Serial cable

Once installed, a shortcut icon appears on the Desktop .
To run the software from the CD:
Choose Run Smart CAT5 switch RS232 Control Software from CD.
5.3.1 Selecting a Com port During the Setup process you will be prompted to choose a Com port. Choose the Com port to which the RS232 Serial cable is connected. Failure to select the correct Com port will result in the software running in demo mode.
Once Setup is complete the Control window appears. See the figure below.

Figure 22 Control window

5.3.2 Computer icons
Computer is connected and switched on
Computer is switched off or unconnected
Computer that you are presently connected to
Connected and switched on computer with a Local Workstation attached and presently being used locally. After remaining idle for the Timeout period, it changes to yellow.
When you first open the Control window the software automatically gets the status of the system, including the security access settings.
5.3.3 Communication Error
If a Communication Error box appears when trying to scan the system – Figure 23.

Figure 23 Communication Error
Check that:
The RS232 Serial cable is connected to the computer’s Serial port and the Smart CAT5 service port.
The Com Port settings in Options / Com Port are set correctly. After changing the Com port exit and re-enter the Control software.
5.3.4 The View menu
From the View menu choose to display:
All computers, or only active switched on computers.
Icon Meaning · The Legend · The toolbar

5.3.5 Selecting a computer
To select a computer:
Click on the computers icon. The system switches to that computer. The connected
icon appears with a red background . Control and monitor the selected computer from the keyboard and mouse connected to the Smart Switch.
5.3.6 The toolbar buttons The toolbar buttons are explained below.
5.3.7 Get Status If for whatever reason there is a break in communication between the Control
software and the system, click
to get the current status of the computers in system. The system automatically updates the status before every switching.
5.3.8 Read Configuration
To see the current settings of the entire system (names, scan settings etc.) click
. All current settings are received. You view the computer settings from the Control window and other settings from the Edit menu – discussed below.
5.3.9 Write Configuration
With the Control software you can make changes to all OSD settings. You can then save these configurations in a file to use in the future by selecting Save or Save As from the File menu.
To change the OSD settings you must press or choose Write Configuration from the File menu after making changes. The changes will then be sent to the Smart system Manager, and the OSD will reflect these changes.
5.3.10 Renaming a computer
To rename a computer:
Or click Save or Save As from the File menu to save the change in a file and not alter the OSD names.

5.3.11 The Edit menu
You can edit all OSD fields. Edit the following from the Edit menu.
5.3.12 Logo and Passwords
You can edit the logo that appears at the top of the OSD window. You can also edit the names and passwords for the Administrator, Supervisor and 6 Users.


Figure 24 Logo Figure 25 Names and passwords
5.3.13 Settings Choose Settings from the Edit menu. The Computers’ Properties box appears. See Figure 26.

Figure 26 Computers’ Properties box
Logo · Passwords · Settings

Here you can edit all the data that can be edited in the OSD. This includes:
Scan times, Timeout, Confirmation label display time, Keyboard type/mode, User access, Password mode, Autoskip mode, and Switch/System hotkey. These features are explained in the OSD section of this Appendix.
To edit a setting:
5.3.13.1 Single computer settings To see all the settings of a single computer, right click the computer icon. The settings appear as in the figure below.

Figure 27 Single computer Settings box
5.3.14 Loading a saved configuration
To load a saved configuration:
From the File menu choose Open.
5.3.15 Reminder!
All changes done with the Control software are only reflected in the OSD AFTER
pressing .
5.3.16 The factory default settings
To revert to the factory default settings:
On the toolbar press . There is no need to press .

When the Smart CAT5 system is password protected, the Control software behaves in exactly the same way as the OSD. You must type in the required password to access the Control software. The access you gain depends on the security status – exactly as with the OSD.
To change the security access, close and reopen the Control software, and type in the different password.
5.4.1 Administrator (Status A)
The Administrator can:
Set and modify all Passwords and security profiles
Fully access any computer
5.4.2 Supervisor (Status S)
The Supervisor can:
Fully access any computer
Scan computers.
5.4.3 User (Status U)
There are 6 different Users in the Smart CAT5 system. Each User has a Profile that defines the access level to different computers. There are 3 different access levels. These are:
Y – Full access to a particular computer
V –Viewing access only, to a particular computer (No keyboard/mouse functionality)
N – No access to a particular computer
The Administrator defines the desired access levels of each User Profile. This is done in the Setting box. By default the User Profile settings are full access.
Use all functions

With the Smart CAT5 Update software program you can upgrade the firmware for the:
Smart CAT5 Update enables you to add new features and fix bugs in a quick and efficient manner. You can also return the OSD to the factory default settings via the Update software. Install the Smart CAT5 Switch Update on any computer, even one not part of the Smart CAT5 system.
The Update software and latest firmware for your system are located on our website at:
http://www.minicom.com/phandlc.htm
The firmware can be downloaded in different ways:
Complete Firmware Package – This includes the firmware for all Smart switches and RICCS and ROCS.
Firmware Package for Smart Switch models - This includes the firmware for all Smart switches.
Smart CAT5 Switch Firmware - There are multiple hardware versions of Smart CAT5 Switch units, each with version specific firmware. On the web page find the description and table that identifies your version.
Firmware Package for RICC and ROC models – Download a firmware package for RICC and ROC models (see the table on the web page for the Supported RICC/ROC models). Or search for and download the specific RICC/ROC models with the correct firmware version.
Pentium 166 or higher with 16 MB RAM and 10 MB free Hard Drive space.
Free Serial port.
Windows 2000 and later.
To update the firmware, the Smart CAT5 system must be connected and switched on.
Manager · ROC/RICCs

Download the Update software and install it on your computer.
6.4.1 Connecting the RS232 Serial cable To run the software, connect the RS232 Serial cable to the computer containing the Update software, and to the Smart CAT5 Switch. See page 26.
desktop , or choose Start/Programs/Smart CAT5 Switch Update/Smart CAT5 Switch Update. The Smart CAT5 Update window appears. See Figure 28.

Figure 28 Smart CAT5 Switch Update window
The table below explains the functions of the buttons and boxes in the Smart CAT5 Switch Update window.
Button or Box Function
Displays the firmware version number
Displays the hardware version number

Button or Box Function
Name of Update file

Figure 29 Com Option box
6.5.1 Verifying the version numbers
Before upgrading the firmware, you must first verify which firmware and hardware versions you have.
6.5.1.1 OSD version number To verify the OSD version number:
The H/W Version button is grayed out, as there is no hardware relevant to the OSD.
Cancels selected function · System time · Displays device status

6.5.1.2 Smart CAT5 Manager version number To verify the Smart CAT5 version number:
6.5.1.3 ROC/RICC version number To verify the RICC version number:
When “Not responding” appears, there is no computer connected, or it is switched off.
6.5.2 Updating the firmware
Never switch off any computer connected to the Smart CAT5 system during the updating process.
To update the firmware:


Figure 30 Open box
6.6 Restoring factory settings You can restore the OSD to the factory settings from the Update software. Note! All changes made (passwords, access rights, names etc.) will be removed. To restore the OSD factory settings: Select Options/Advanced/Set default. The OSD returns to the factory default settings. (You can also restore the OSD from the OSD (F7), see page 19).
This section covers:
Getting the current status
Resetting the units · Communication Error message · Electricity failure

6.7.1 Resetting the units
Resetting can be done from the Update software or from the Smart CAT5 switch.
Resetting through the Update software
Reset the software for the Smart CAT5 Manager or ROC/RICCs when for example the unit hangs or when the mouse fails to work properly. Resetting is done via the Serial port, and avoids the need to shut down the computer.
To reset the Switch or RICC units:
For the ROC/RICCs, check one or more ROC/RICCs.
Resetting from the Smart CAT5 switch
To reset from the Switch press the 2 front panel Select buttons simultaneously. The ROC/RICCs are unaffected by this reset.
6.7.2 Getting the current status
If there is a break in communication between the Update software and the system, select Options/Get Number of Ports to get the current status of the system.
6.7.3 Communication Error message
When using Firmware Update software you may sometimes get a Communication Error message.
When updating a unit and a Communication Error message appears, do the following:

6.7.4 Electricity failure
When the electricity fails while updating the Smart CAT5 firmware, do the following:
If the electricity fails during the firmware update of the Switch, a Communication Error message appears. Simply resume the firmware update by opening the folder that contains the firmware update file and continue from there.
If the electricity fails during the firmware update of the ROC/RICCs a Not Responding or Upgrade Error message appears. Restart the upgrade from the beginning.

By default the RICC SUN supports US English keyboard emulation. It also supports German and Swiss German keyboard emulation. You can download the appropriate keyboard emulation firmware from our website www.minicom.com in the Support section on the Smart CAT5 Switch Upgrades page. Upload the firmware to the RICC SUN.
Other language keyboard emulations will be posted on the Minicom Web site as they become available.

The connected PS/2 keyboard does not have a special SUN keypad to perform special functions in the SUN Operating System environment. So when a ROC/RICC USB or SUN is connected to a SUN computer, the ROC/RICC emulates these SUN keys using a set of key combinations called Combo keys. See the table below.
SUN key Combo key
Stop Left Ctrl + Left Alt + F1
Props Left Ctrl + Left Alt + F3
Front Left Ctrl + Left Alt + F5
Open Left Ctrl + Left Alt +F7
Find Left Ctrl + Left Alt + F9
Again Left Ctrl + Left Alt + F2
Undo Left Ctrl + Left Alt + F4
Copy Left Ctrl + Left Alt + F6
Paste Left Ctrl + Left Alt + F8
Cut Left Ctrl + Left Alt + F10
Help Left Ctrl + Left Alt + F11
Compose Application key or Left Ctrl + Left Alt + Keypad *
Volume Up Left Ctrl + Left Alt + Keypad –
Volume Down Left Ctrl + Left Alt + Keypad +
Mute Left Ctrl + Left Alt + F12
Sun Left ◊ key Left Windows key
Sun Right ◊ key Right Windows key
Alt-Graph Right Alt or Alt Gr
Stop A Left Ctrl + Left Alt +1
Crescent Scroll Lock


DOS, Windows, LINUX, UNIX, MAC and all other major operating systems
System cable CAT5/ 5E/ 5+/ 6/ or 7 cables. FTP or UTP 2x4x24 AWG solid wire
Transmission distance RICCs up to 10m/33ft. RoCs up to 30m/99ft.
215.0 x 122.0 x 41.5mm / 8.46 x 4.80 x 1.63in
Weight – 108/116 Product – 920g / 2lbs Shipping – 1.87Kg / 4.1lbs
Power supply – 108/116 Internal switching 85-260 VAC 50 / 60 Hz
Product weight All RICCs 107g / 0.23lb. - All RoCs 100g / 0.20lb
Shipping weight All RICCs 300g / 0.66lb - All RoCs 172g / 0.38lb
Dimensions All RICCs 91 x 41 x 24mm / 3.58 x 1.61 x 0.94”
All RoCs 65 x 25 x 25mm / 2.55 x 0.98 x 0.98”

The device must only be opened by an authorized Minicom technician. Disconnect device from AC mains before service operation!
WEEE Information for Minicom Customers and Recyclers
Under the Waste Electrical and Electronic Equipment (WEEE) Directive and implementing regulations, when customers buy new electrical and electronic equipment from Minicom they are entitled to:
Send old equipment for recycling on a one-for-one, like-for-like basis (this varies depending on the country)
Send the new equipment back for recycling when this ultimately becomes waste
Instructions to both customers and recyclers/treatment facilities wishing to obtain disassembly information are provided in our website www.minicom.com

201204196 • 933193