High Resolution Digital Audio Interface Unit O WNER’S MANU AL CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE PARTS INSIDE.
2 TASCAM IF-AE8HR Important Safety Precautions IMPOR T ANT (f or U .K. Customers) DO NOT cut off the mains plug from this equipment. If the plug fitted is not suitable for the power points in your home or the cable is too short to reach a power point, then obtain an appropriate safety approved extension lead or consult your dealer.
TASCAM IF-AE8HR 3 CA UTION: … Read all of these Instructions. … Save these Instructions f or later use. … Follow all W arnings and Instructions marked on the audio equipment. 1) Read Instructions — All the safety and operating instructions should be read before the product is operated.
4 TASCAM IF-AE8HR TASCAM IF-AE8HR 1 Intr oduction The T ASCAM IF-AE8HR provides a con venient way of exchanging digital audio data between TDIF-1- equipped de vices, such as DTRS recorders, and AES/ EBU de vices. A single TDIF-1 connector carries eight channels of digital input and output.
TASCAM IF-AE8HR TASCAM IF-AE8HR 5 occurs if there is no clock signal or the signal is ±6% outside the nominal frequency . In these cases, once a v alid clock signal is recei ved again, the indicator will light steadily .
TASCAM IF-AE8HR 6 TASCAM IF-AE8HR NO TE If WOR D is selected as the clock source, and a high- frequency sampling frequency has been selected ( 88.2k or 96k ), but the incoming w ord sync clock is norm al speed, note that this is not shown as an error by flashing indicators .
TASCAM IF-AE8HR TASCAM IF-AE8HR 7 A WOR D SY N C – THRU (A UT O TERM) This BNC connector echoes the word clock which is input at the WORD SYNC – IN connector 9 . If no connection is made to this connector , it is auto- matically terminated. B WOR D SY N C – OUT (STD Fs) This BNC connector outputs a standard-frequency word clock: either 44.
TASCAM IF-AE8HR 5.1 Dimensional drawing Leve l TT L leve l ( 75 Ω ) WORD SYNC OUT (STD Fs) Connector BNC Leve l TT L leve l ( 75 Ω ) (44.1 kHz, 48 kHz) WORD SYNC OUT (HI Fs) 75 Ω , outputs high-frequency clock Connector BNC Leve l TT L leve l ( 75 Ω ) (88.
An important point after buying a device Tascam IF-AE8HR (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Tascam IF-AE8HR yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Tascam IF-AE8HR - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Tascam IF-AE8HR you will learn all the available features of the product, as well as information on its operation. The information that you get Tascam IF-AE8HR will certainly help you make a decision on the purchase.
If you already are a holder of Tascam IF-AE8HR, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Tascam IF-AE8HR.
However, one of the most important roles played by the user manual is to help in solving problems with Tascam IF-AE8HR. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Tascam IF-AE8HR along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center