Instruction/ maintenance manual of the product D13192 TANDBERG
Go to page of 40
Technical Description of TANDBER G Ga teway with software v ersion G2 TANDBER G D1319 2 Rev. 02.
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 2 Table of contents 1 INTRODU CTION ......... .... ....... ....... ....... ....... ...... ....... ....... ....... ....... ...... ....... ....... ....... ....... ....
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 3 4.5 .2 Teleph ony ...... ...... ....... ....... ..... ...... ....... ....... ....... ....... ....... ...... ....... ....... ....... ....... ...... ....... ....... .
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 4 1 Introduction The TANDBERG Gateway is designed to connect up to 8 videoconferencin g calls and 8 telepho ne calls simultaneously betwee n IS DN and I P Networks. The TANDBERG Gateway supports th e I TU-T H.
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 5 • Dual Stream - support s Duo Vide o TF on ISDN and IP, and People+Co ntent on ISDN.
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 6 4 TANDBERG Gatew ay Int erfaces & Fe atures Ext ensive use of industr y standard interfaces and connectors ensur e effortless integration o f extern al equipment with the TANDBERG Gateway .
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 7 4.1.2 PR I E1/T1 ISDN 4.1.2.1 I SDN num ber plan The TANDBERG Gateway’s PRI lines may use one or m ore numbers for d ial in. If more than one n umber is u sed, the numbers m ust be conse cutive.
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 8 Pinout of PRI E1/T1 I nterfac e: 4 NOTE: TANDBERG recommends always using category 5 cabling. PRI T1 (US onl y): Networ k Service Facility (NSF) can be c onfig ured as blan k/no value (i.
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 9 4.1.3 Dial In Services 4.1.3.1 Direct Inwards Dialing (DID) By enabling this feature, it is possible to mak e a dire ct mapping between ISDN numbers and H323 aliases.
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 10 4.1.3.4 Ho tline When calling the Hotl ine number spe cified in the TAN DBE RG Gateway, the call is automatically transferred to a predefin ed H.323 alias. This feature can be used w hen an operator or helpdesk is needed.
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 11 which packets to send first and which to throw away. Some information/traffic is time critical while ot her is not, and classification is used to differentiate this traffic.
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 12 An example of this is automa tic adjustment of tota l bandwidth used when DuoVide o i s opened. 4.1.5.3 Dynamic playou t buff ering Shapes the inc oming da ta for be tter play out and re-se quenc ing of pa cket de livere d out of order.
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 13 4.1.5.7 Laye r 4 Ports used in H.323 The following tables describe s which lay er 4 ports are being used by the TANDBERG Gateway when a call is made on an H.323 network.
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 14 4.1.5.9 In telligent Packet L oss Recovery (IPLR) I PLR is an ITU standards based pack et loss compensation fo r H.323 that i mproves received video into the TAN DBERG Gatew ay .
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 15 4.1.6 LEDs Description The TANDBERG Gateway has 24 LEDs (L ight Em itting Diodes) on the front p anel.
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 16 Scenario: TANDBERG Gateway is connected v ia a CSU (i.e. a NT ‘Network Termination’) as follows : TANDBER G.
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 17 4.1.8 TANDBERG G ateway Capacity The tot al capacity of the TANDBERG Gateway is defin ed by the followi ng rules. I. Maxi mum 8 video c alls and 8 teleph ones calls.
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 18 4.1.8.1 TAND BERG Gateway Capa ci ty – typica l scenarios for 4Mb Option I n t he table below some typical capacity scenarios are li sted (they can be derived by the calculation abo ve): Band width Non -e ncry pted (Max.
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 19 which encry pts "the session key s". Wh en the session are coll ected by th e remote end, en cry ption of the audio, video and data channels c an start.
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 20 4.2 Aggregation Stan dards ISD N Aggregation H.221 Frame Structu re from 64 (56 * ) k bps to 12 8 kbps ISO 13871 BOND ING , Mode 1 from 64 (56 * ) kbps t o 2 Mbps H0 O ne 38 4 kbps channel 4.
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 21 4.3 RS232 Interface/Application Progra m m able Interface (API) Data Sta ndards Data TANDBERG Dynamic Da ta Cha.
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 22 4.4 Video Features The TANDBERG Gateway supports the ITU video standards H.26 1, H.263, H .263+ and H .264. 4.4.1 Optim ised Video Com pression The I TU standard H.
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 23 4.4.4 Duo Video The TANDBERG Gateway is capable of receiving/transmitting two si multaneous video signals from/t o the connected sites 7 on all call rates fr om 128kbps and a bove.
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 24 4.5 Audio Fe atures 4.5.1 Custom Sounds The TANDBERG Gateway has a variety of sounds that may b e changed by storing new f iles on the FTP fil e sy stem of the TA NDBERG Gateway.
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 25 4.6 System Manage m ent TANDBERG provi des a comprehensive set o f management too ls, and is committ ed to the use o f standard s-based tools.
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 26 operating sy stems), wh ich includes t he necessary pro grams such as: • An FTP clien t (please see ‘Upgrad.
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 27 remotely . Loc al mana geme nt, control and sof tware upgra de facilities are also availa ble throug h a standard RS232 interface. 4.6.4 System Managem ent F u nctionality 4.
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 28 • SSL Secure Sockets L ay er, protocol develop ed by Netscape for transmitting private documents via the Internet. SSL works by using a private key to encrypt data that is transfe rred ove r the SSL conne ction.
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 29 I t is also important to understand that only the password is protected with this service. The actual connectio n is not en cry pted, and can be sniffed as for a normal teln et connection.
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 30 4.6.6 Layer 4 ports u sed by the system The fol lowing TC P and UDP p orts are relevan t for the TANDBERG Gateway. Function Por t Type Direction Gatekeep er RAS 1719 UDP ⇔ Gatekee per Discove ry 224.
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 31 5 Miscellaneous features 5.1 Ph one bo ok The TANDBERG Gateway can store up to 1 00 numbers in the phonebook . The phonebook may be edited th rough the web in terface or by editin g the dir.
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 32 Directory - dir.prm This file contains the d irectory /phonebook o f the TANDBERG G ateway .
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 33 6 En vir onme nta l Issue s 6.1 TANDBERG ’s Envi ronme ntal Policy • TANDBERG’s Research and Development .
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 34 7 Product Approvals The prod uct has been appro ved by va rious i nternational ap proval agencies, am ong others: UL, BABT and NEMKO.
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 35 7.6 NEBS approval This produc t com plies with the standar ds GR-63 -CORE and GR-1 089-CORE an d is NEBS approved by U L . For NEBS compliance, the product should be installed in the following manner : - Use the enclosed rack brackets marked "NEBS".
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 36 8 Product Reliability The predicted reliab ility of the TANDBER G Gateway is expressed in th e expected rand om Mean Time Be t we en Failures ( MTBF) for the elec t ronic components base d on the P ow er On Hours (P OH).
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 37 9 Technical specification of TANDBERG Gateway 9.1 Mech anical inform ation 10 TANDBERG Gatew ay Height 4.4 cm 1.7 in Width 44.2 cm 17.4 i n Depth 31.8 cm 12.5 in Weight 5 .
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 38 9.3 Operating Temperature and Hum i dity • 0 ° C to 35 ° C (32 ° F t o 95 ° F) ambient temperatu re.
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 R ev. 02 39 10 Technical Sp e cification sh eet System Capacity Maximu m n umber of video conferencin g calls: 8 Maxim um nu mber of audio cal ls: 8 Endpoints Supported H.320 con fer encin g en dpoin ts H.
Technical D escriptio n of TANDBERG Gateway with soft ware version G2 D13192 Rev . 02 40 System Ma nagem ent To tal management via e mbedde d WE B ser ver using HTTP S , S NM P, Tel ne t a nd FTP 1 x .
An important point after buying a device TANDBERG D13192 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought TANDBERG D13192 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data TANDBERG D13192 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, TANDBERG D13192 you will learn all the available features of the product, as well as information on its operation. The information that you get TANDBERG D13192 will certainly help you make a decision on the purchase.
If you already are a holder of TANDBERG D13192, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime TANDBERG D13192.
However, one of the most important roles played by the user manual is to help in solving problems with TANDBERG D13192. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device TANDBERG D13192 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center