WALL MOUNTED PACKAGE AIR CONDITIONERS
Model: W12A2-A W12A1-K

Bard Manufacturing Company, Inc. Bryan, Ohio 43506
Since 1914 Moving ahead just as planned.



These publications can help you install the air conditioner or heat pump. You can usually find these at your local library or purchase them directly from the publisher. Be sure to consult current edition of each standard.
ACCA Air Conditioning Contractors of America 1712 New Hampshire Avenue NW Washington, DC 20009 Telephone: (202) 483-9370 Fax: (202) 234-4721
National Electrical Code ANSI/NFPA 70
Standard for the Installation of ANSI/NFPA 90A Air Conditioning and Ventilating Systems
ANSI American National Standards Institute 11 West Street, 13th Floor New York, NY 10036 Telephone: (212) 642-4900 Fax: (212) 302-1286
Standard for Warm Air Heating ANSI/NFPA 90B and Air Conditioning Systems
ASHRAE American Society of Heating, Refrigerating and Air Conditioning Engineers, Inc. 1791 Tullie Circle, NE Atlanta, GA 30329-2305 Telephone: (404) 636-8400 Fax: (404) 321-5478
Load Calculation for ACCA Manual J Residential Winter and Summer Air Conditioning
Duct Design for ACCA Manual D Residential Winter and Summer Air Conditioning and Equipment Selection
NFPA National Fire Protection Association Batterymarch Park P.O. Box 9101 Quincy, MA 02269-9901 Telephone: (800) 344-355 Fax: (617) 984-7057
Manufactured under the following U.S. patent numbers:
5,485,878 and 5,301,744

W 12 A 2 – A 00 X J
REVISIONS CONTROL MODULES E - Low Ambient Control J - Telecommunication VOLTS & PHASE A - 230/208/60/1 K - 115/60/1
CAPACITY 12 - 1 Ton
KW 00 - No KW 02 - 2.2 KW 03 - 3.6 KW 05 - 5.0 KW
COIL OPTIONS X - Standard Coils
COLOR OPTIONS X - Beige 4 - Buckeye Gray OUTLET OPTIONS X - Front
VENTILATION OPTIONS X - Barometric Fresh Air Damper (Standard) B - Blank-off Plate E - Economizer (Internal) - Fully Modulating with Exhaust V - Commercial Ventilator - Motorized with Exhaust
FILTER OPTIONS X - 1-Inch Throwaway (Standard) P - 2-Inch Pleated
j With blower watts included



Return air opening is in lower Return air opening is in upper


Heater and Filter Access
is Blow Thru Condenser Airflow
Front View Right Side View
( * ) Position of return air flanges are interchangeable between two positions. Factory built at 5 inches. Note: Maintain a minimum of 20 inches clearance on right side to allow access to control panel and allow proper airflow to outdoor condenser coil. Allow 15 inches on left side.
(*) Position of return air flanges are interchangeable between two positions. Factory built at 5 inches. NOTE: Maintain a minimum of 20 inches clearance on right side to allow access to control panel and allow proper airflow to outdoor condenser coil. Allow 15 inches on left side.

Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors.
Based on 75°C copper wire. All wiring must conform to NEC and all local codes.
These “Minimum Circuit Ampacity” values are to be used for sizing the field power conductors. Refer to the National Electrical Code (latest revision), article 310 for power conductor sizing.
These instructions and any instructions packaged with any separate equipment required to make up the entire air conditioning system should be carefully read before beginning the installation. Note particularly “Starting Procedure” and any tags and/or labels attached to the equipment.
Upon receipt of equipment, the carton should be checked for external signs of shipping damage. If damage is found, the receiving party must contact the last carrier immediately, preferably in writing, requesting inspection by the carrier’s agent.
While these instructions are intended as a general recommended guide, they do not supersede any national and/or local codes in any way. Authorities having jurisdiction should be consulted before the installation is made. See Page 3 for information on codes and standards.
The equipment covered in this manual is to be installed by trained, experienced service and installation technicians.
The refrigerant system is completely assembled and charged. All internal wiring is complete.
Size of unit for a proposed installation should be based on heat loss/gain calculation made according to methods of Air Conditioning Contractors of America (ACCA). The air duct should be installed in accordance with the Standards of the National Fire Protection Association for the Installation of Air Conditioning and Ventilating Systems of Other Than Residence Type, NFPA No. 90A, and Residence Type Warm Air Heating and Air Conditioning Systems, NFPA No. 90B. Where local regulations are at a variance with instructions, installer should adhere to local codes.
The unit is designed for use with or without duct work. Flanges are provided for attaching the supply and return air ducts.
These instructions explain the recommended method to install the air cooled self-contained unit and the electrical wiring connections to the unit.

FRESH AIR INTAKE
All duct work, supply and return must be properly sized for the design air flow requirement of the equipment. Air Conditioning Contractors of America (ACCA) is an excellent guide to proper sizing. All duct work or portions thereof not in the conditioned space should be properly insulated in order to both conserve energy and prevent condensation or moisture damage.
All units are built with fresh air inlet slots punched in the service panel.
If the unit is equipped with a fresh air damper assembly, the assembly is shipped already attached to the unit. The damper blade is locked in the closed position. To allow the damper to operate, the maximum and minimum blade position stops must be installed. See Figure 2.
Refer to Table 6 for maximum static pressure available for duct design.
All capacity, efficiency and cost of operation information as required for Department of Energy “Energyguide” Fact Sheets is based upon the fresh air blank-off plate in place and is recommended for maximum energy efficiency.
Design the duct work according to methods given by the Air Conditioning Contractors of America (ACCA). When duct runs through unheated spaces, it should be insulated with a minimum of one inch of insulation. Use insulation with a vapor barrier on the outside of the insulation. Flexible joints should be used to connect the duct work to the equipment in order to keep the noise transmission to a minimum.
The blank-off plate is available upon request from the factory and is installed in place of the fresh air damper shipped with each unit.
Ducts through the walls must be insulated and all joints taped or sealed to prevent air or moisture entering the wall cavity.
This unit employs an automatic condensate disposal system consisting of a base drain pan, drain valve and fan blade with slinger ring. A plastic drain hose extends from the evaporator drain pain at the top of the unit to the base drain pan at the bottom. At temperatures above 40°, the drain valve located between the condenser coil and fan shroud is closed allowing water to build up in the base to a height of 5/8" to 3/4". The fan blade with slinger then rotates in this water and throws the water onto the condenser coil. This disposes of the water by evaporating it on the hot condenser.
Some installations may not require any return air duct. It is recommended that on this type of installation that a filter grille be located in the wall. Filters must be of sufficient size to allow a maximum velocity of 400 FPM.
installation codes may limit this cabinet to installation only in a single story structure.
At temperatures below 40°, the drain valve opens draining the base pan and preventing freeze ups that could damage the coil or fan blade.
A one inch throwaway filter is supplied with each unit. The filter slides into position making it easy to service. This filter can be serviced from the outside by removing the service door. A 2-inch pleated filter is also available as an optional accessory. The internal filter brackets are adjustable to accommodate the 2-inch filter by bending the metal tabs holding the 1-inch filter down. There are two tabs on each side of the filter.


bolts; use 7/8 inch diameter flat washers on the lab bolts.
which secure the unit to the outside wall surface at both sides.
length of top. See Figure 3.
strong and rigid enough to carry the weight of the unit without transmitting any unit vibration.
and supply air frames or collars can be drilled and screwed or welded to the structural wall itself (depending upon wall construction). Be sure to observe required clearance if combustible wall.
to insure that they are capable of carrying the weight of the installed unit.
of 20 inches clearance on right side to allow access to control panel and allow proper airflow to outdoor coil. Additional clearance may be required to meet local or national codes.
must be cut through the wall as shown in Figure 3.
Figure 3.
rain flashing is shipped attached to the back of the unit on the right side.








WIRING – LOW VOLTAGE WIRING
Refer to the unit rating plate for wire sizing information and maximum fuse or “HACR” type circuit breaker size. Each outdoor unit is marked with a “Minimum Circuit Ampacity”. This means that the field wiring used must be sized to carry that amount of current. Depending on the installed KW of electric heat, there may be two field power circuits required. If this is the case, the unit serial plate will so indicate. All models are suitable only for connection with copper wire. Each unit and/or wiring diagram will be marked “Use Copper Conductors Only”. These instructions must be adhered to. Refer to the National Electrical Code (NEC) for complete current carrying capacity data on the various insulation grades of wiring material. All wiring must conform to NEC and all local codes.
230/208, 1 phase equipment use dual primary voltage transformers. All equipment leaves the factory wired on 240V tap. For 208V operation, reconnect from 240V to 208V tap. The acceptable operating voltage range for the 240 and 208V taps are:
power connection point in the unit and while the unit is operating at full load (maximum amperage operating condition).
The electrical data lists fuse and wire sizes (75°C copper) for all models, including the most commonly used heater sizes. Also shown are the number of field power circuits required for the various models with heaters.
The unit rating plate lists a “Maximum Time Delay Relay Fuse” of “HACR” type circuit breaker that is to be used with the equipment. The correct size must be used for proper circuit protection and also to assure that there will be no nuisance tripping due to the momentary high starting current of the compressor motor.
For wiring size and connections, refer to Wiring Manual 2100-507.

THESE UNITS REQUIRE R-410A REFRIGERANT AND POLYOL ESTER OIL.
REMEMBER: When adding R-410A refrigerant, it must come out of the charging cylinder/tank as a liquid to avoid any fractionation, and to insure optimal system performance. Refer to instructions for the cylinder that is being utilized for proper method of liquid extraction.
Failure to conform to these practices could lead to damage, injury or death.
If a leak has occurred in the system, Bard Manufacturing recommends reclaiming, evacuating (see criteria above), and charging to the nameplate charge. If done correctly, topping off the system charge can be done without problems.
With R-410A, there are no significant changes in the refrigerant composition during multiple leaks and recharges. R-410A refrigerant is close to being an azeotropic blend (it behaves like a pure compound or single component refrigerant). The remaining refrigerant charge, in the system, may be used after leaks have occurred and then “top-off” the charge by utilizing the pressure charts on the inner control panel cover as a guideline.

During routine operation of the unit with no power interruptions the compressor will operate on demand with no delay.
For improved start up performance, wash the indoor coil with a dishwasher detergent.
SERVICE HINTS
If the high pressure switch opens, the compressor contactor will de-energize immediately. The lockout timer will go into a soft lockout and stay in soft lockout until the high pressure switch closes and the delay on break time has expired. If the high pressure switch opens again in this same operating cycle the unit will go into manual lockout condition and the alarm relay circuit will energize. Recycling the wall thermostat resets the manual lockout.
times. Also not to needlessly close off supply and return air registers. This reduces airflow through the system which shortens equipment service life as well as increasing operation costs.
switch.
they are the correct rating.
and unrestricted airflow circulation is essential.
If the low pressure switch opens for more than 120 seconds, the compressor contactor will de-energize and go into a soft lockout. Regardless the state of the low pressure switch, the contactor will reenergize after the delay on make time delay has expired. If the low pressure switch remains open, or opens again for longer that 120 seconds, the unit will go into manual lockout condition and the alarm relay circuit will energize. Recycling the wall thermostat resets the manual lockout.
The W12Aà models are supplied with a remote reset high and low pressure switch. If tripped, this pressure switch may be reset by turning the thermostat off then back on again.
HEATING – Circuit R-Y makes at thermostat pulling in compressor contactor, starting the compressor and outdoor motor. The G (indoor motor) circuit is automatically completed on any call for cooling operation or can be energized by manual fan switch on subbase for constant air circulation. On a call for heating, circuit R-W1 make at the thermostat pulling in heat contact for the strip heat and blower operation.
Alarm terminal is output connection for applications where alarm relay is employed. This terminal is powered whenever compressor is locked out due to HPC or LPC sequences as described.
are inherently automatic reset devices. The high pressure switch and low pressure switch cut out and cut in settings are fixed by specific air conditioner or heat pump unit model. The lockout features, both soft and manual, are a function of the Compressor Control Module.
The compressor control module is optional on the models covered by this manual. The compressor control is an anti-short cycle/lockout timer with high and low pressure switch monitoring and alarm relay output.
On initial power up or any time power is interrupted to the unit the delay on make period begins, which will be 2 minutes plus 10% of the delay on break setting. When the delay on make is complete and the high pressure switch (and low pressure switch if employed) is closed, the compressor contactor is energized. Upon shutdown the delay on break time starts and prevents restart until the delay on break and delay on make periods have expired.

PRESSURE SERVICE PORTS
Adjustable Delay on Make and Delay on Break Timer
High and low pressure service ports are installed on all units so that the system operating pressures can be observed. Pressure chart can be found later in the manual covering all models. It is imperative to match the correct pressure chart to the unit by model number.
The potentiometer is used to select Delay on Break time from 30 seconds to 5 minutes. Delay of Make (DOM) timing on power up and after power interruptions is equal to 2 minutes plus 10% of Delay of Break (DOB) setting:
0.5 minute (30 seconds) DOB = 123 second DOM 1.0 minute (60 seconds) DOB = 126 second DOM 2.0 minute (120 seconds) DOB = 132 second DOM 3.0 minute (180 seconds) DOB = 138 second DOM 4.0 minute (240 seconds) DOB = 144 second DOM 5.0 minute (300 seconds) DOB = 150 second DOM
During routine operation of the unit with no power interruptions the compressor will operate on demand with not delay.
Unit No. 1: DOB set at 2 minutes, and DOM is 132 seconds.
Unit No. 2: DOB set at 4 minutes, and DOM is 144 seconds.

TABLE 4 INDOOR BLOWER
Shown in Figure 7 is the correct fan blade setting dimension for proper air delivery across the outdoor coil.
Any service work requiring removal or adjustment in the fan and/or motor area will require that the dimension below be checked and blade adjusted in or out on the motor shaft accordingly.

530 / 500 485 / 460 440 / 425 390 / 375 325 / 300
465 / 425 415 / 400 365 / 350 315 / 300 270 / 265

TABLE 5 RATED CFM AND ESP RECOMMENDED AIRFLOW RANGE
ESP
W12Aà 400 .10 500 - 300
° Rated CFM and ESP on low speed tap.
TABLE 6 MAXIMUM ESP OF OPERATION
ELECTRIC HEAT ONLY
W12A2-A00
.35 .35 .35
W12A1-K00
.35 .35
This unit was charged at the factory with the quantity of refrigerant listed on the serial plate. AHRI capacity and efficiency ratings were determined by testing with this refrigerant charge quantity.
Values shown are for units equipped with STD 1" throwaway filters. Derate ESP by .15 for 2" pleated filters.
The following pressure tables show nominal pressures for the units. Since many installation specific situations can affect the pressure readings, this information should only be used by certified technicians as a guide for evaluating proper system performance. They shall not be used to adjust charge. If charge is in doubt, reclaim, evacuate and recharge the unit to the serial plate charge.

COOLING Air Temperature Entering Outdoor Coil °F

Model Return Air Temperature Pressure 75° 80° 85° 90° 95° 100° 105° 100° 115°
75 deg. DB 62 deg. WB Low Side High Side
120 291 124 310 129 332 133 355 136 379 138 405 141 432 142 460 143 490
80 deg. DB 67 deg. WB Low Side High Side
128 298 133 318 138 340 142 364 143 387 148 415 151 443 152 472 153 503
85 deg. DB 72 deg. WB Low Side High Side
132 308 138 329 143 352 147 377 150 403 153 430 156 459 157 489 158 521
Low Side Pressure +4 PSIG High Side Pressure +10 PSIG

W12Aà · Model Description
What the fault codes shown on the display mean and how to clear them.
| Code | Meaning | Fix | |
|---|---|---|---|
| R-12 | Although nearly azeotropic, charge with | p.13 |