Instruction/ maintenance manual of the product UVF-36 Superior
Go to page of 20
36" x 24", 36" x 28" & 42" x 28" Universal Vent-Free Fireboxes P/N 700,032M REV . B 05/2006 MODELS UNIVERSAL VENT -FREE FIREBOX Due to high temperatures, the appliance should be located out of traffi c and away from furniture or draperies.
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. 2 IMPORT ANT SAFETY INFORMA TION INST ALLER: PLEASE LEA VE THESE INSTRUC- TIONS WITH THE OWNER. OWNER: PLEASE RET AIN THESE INSTRUC- TIONS FOR FUTURE REFERENCE.
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. 3 Misc. Codes / Standards - The Installation must conform to local codes or , in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. 4 Y our options are: a. Rework equations adding the space of adjoin- ing room(s). If the extra volume provides an unconfi ned space, then remove door or add ventilation grills between rooms. Refer to National Fuel Gas Code, ANSI Z223.
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. 5 Note: The following requirements reference various Massachusetts and national codes not contained in this document. Requirements for the Commonwealth of Massachusetts Un-vented Room Heaters shall be installed in accordance with 527 CMR 30.
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. 40" 16" Optional Hearth Extension Fireplace Opening Top Stand- Off Spacer (on appliance) Top of Appliance Finished Wall Header Shown with Canopy Installed (required on UVF-36 only) Non-Combustible Material 3" Min.
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. 7 Noncombustible material (minimum requirements) with wood mantel or other combustible projections: T o install the fi rebox with a wood mantel, shelf or other combustible projection above fi rebox opening.
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. 8 Consult all local codes. Properly size and route the gas supply line from the supply regulator to the area where the appliance is to be installed per requirements outlined in the National Fuel Gas Code, NFP A 54 - latest edition (USA) or B149 - latest edition (Canada).
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. Figure 7 8d Nail Top Spacer 9 The fi rebox may be positioned and then the framing built around it, or the framing may be constructed and the fi rebox positioned into the opening. Usually , no special fl oor support is needed for the fi rebox, however , to be certain: 1.
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. 10 Figure 8 SPECIFICA TIONS Gas Line Access - Both Sides Access Opening for Junction Box - Right Side Only (remove the knock-out before installing J-Box). J-Box / Electrical Kit is not provided with appliance.
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. A B 11 FRAMING SPECIFICA TIONS Figure 9 Canopy Kit Installation (see ordering information on Page 16 ) NOTE: A canopy comes standard and is required for model U VF-36.
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. 12 OPTIONAL EQUIPMENT Blower Kits The FBK-100 Blower Kits are used when a wall-mounted ON/OFF blower switch is desired, and the FBK-200 Blower Kits are used when a wall-mounted variable speed blower control (rheostat) is desired.
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. 13 Step 1. Follow the instructions below for the model you are installing: Model UVF-36: Using a screwdriver remove the screw from the blower access panel as shown in Figure 18. Slide the panel to the right until the fl ange clears the opening.
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. 14 Step 8. Ensure that power supply wires are NOT "live" before making these connections).
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. 15 FIREBOX FINISHES There are a wide variety of “fi nished looks” for your built-in Vent-Free fi rebox from formal wall decor with elaborate mantels to rustic wood paneling or warm brick facings.
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. 16 Outside Air Gate & Duct Kit Cat. No. Model No. Description H3991 OAK-UVFRC Outside Air Gate & Duct Kit Outside Air Gate & Duct Kit These kits have an air gate assembly , 4" diam- eter duct and a termination hood.
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. 17 6 No. Description UVF-36 UVFRC-3628 UVFRC-3628-H UVFRC-4228 UVFRC-4228-H Part No. Qty . Part No. Qty . Part No. Qty. Part No. Qty . Part No. Qty . Gas Fireplace Assembly - - - - - - - - 1. Firescreen H3814 2 H3820 2 H3820 2 H3827 2 H3827 2 2.
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. 18 NOTES.
NOTE: DIAGRAMS & ILLUSTRA TION ARE NOT TO SCALE. 19 NOTES.
Printed in U.S.A. © 2006 by LHP P/N 700,032M REV . B 05/2006 LHP 1110 West T aft Avenue • Orange, CA 92865 The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifi cations, prices and also to discontinue colors, styles and products.
An important point after buying a device Superior UVF-36 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Superior UVF-36 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Superior UVF-36 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Superior UVF-36 you will learn all the available features of the product, as well as information on its operation. The information that you get Superior UVF-36 will certainly help you make a decision on the purchase.
If you already are a holder of Superior UVF-36, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Superior UVF-36.
However, one of the most important roles played by the user manual is to help in solving problems with Superior UVF-36. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Superior UVF-36 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center