Instruction/ maintenance manual of the product SLBV-40PM Superior
Go to page of 28
SLBV-35NE SLBV-40NE SLBV-35NM SLBV-35PM SLBV-40NM SLBV-40PM ITS Report No. 100017854 Please read and understand these instructions BEFORE starting installation. MODELS I N S T A L L A T I O N I N S T R U C T I O N S B-Vent Gas Fireplaces SLBV 35/40 Models MILLIVOL T : ELECTRONIC: P/N 506009-02 Rev .
S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S Packaging ......................................... Page 2 Introduction ...................................
S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S Note: Installation and repair should be done by a qualified ser vice person. The appliance should be inspected before use and at least annually by a professional ser vice person.
S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S Figure 2 - Dexen Electronic Gas Valve Pilot Stage T ermi.
S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S COLD CLIMA TE INSULA TION For cold climate installations, seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room.
T ermination Heights For V ents Above Flat Or Sloped Roofs Ref. NFP A 54 / ANSI Z223.1 Roof Pitch * F ee t * M e t e r s Flat to 6/12 1.0 0.3 6/12 to 7/12 1.25 0.38 7/12 to 8/12 1.5 0.46 8/12 to 9/12 2.0 0.61 9/12 to 10/12 2.5 0.76 10/12 to 11/12 3.25 0.
5 ( 1 27 ) 8-1/4 ( 2 09 ) 14 ( 3 56 ) 12 ( 3 05 ) 19 ( 48 3) 8 (203) 2 ( 51 ) 4 ( 10 2 ) 6 ( 15 2 ) 8 ( 20 3 ) 10 ( 25 4 ) 12 ( 30 5 ) 10 (254) 14 (356) 18 (457) 16 (406) 12 (305) T op of Appl iance inches (millimeters) Mant el Dep th No te - H ood sh own as po sit ion ed.
PRE-INST ALLA TION STEPS (Remove Glass Enclosure Panel) The appliance is shipped with all gas controls and components installed and pre-wired. Note: Remove the glass enclosure panel before installing the fireplace. T o remove the glass enclosure panel: 1.
S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S FIREPLACE AND FRAMING SPECIFICA TIONS NO TE: Diag ram s, i llus tra tion s an d ph otog raph s a re n ot t o s cale .
S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S VERTICAL VENTING THROUGH CEILING Frame Ceiling Opening: T o locate the center of the vertical run, use a plumb line from the ceiling above the appliance.
Note: • All appliances are factory-equipped with a ex ible gas line con nector and 1/2 inc h shutof f valve (se e Figure 17 on Page 15 ) . • See Massac husetts Requi rements on Pa ge 4 for additional requirements for installa- tions in the state of Massachusetts in the USA.
S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S 12 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Step 4. Install Field Wiring CAUTION Ground supply lead must be con- nected to the wire attached to the green ground screw located on the outlet box.
S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S 13 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Figure 12 MILLIVOL T WIRING DIAGRAM CAU TION : WH EN S ERVI CING CON TROL S, LA BEL ALL WIRE S PR IOR TO D ISCO NNECT ION.
S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S Step 5.
S U PE R I O R ® B- V E N T G A S F I R E PL A C E S • MO D E L S S L B V - 35 , S LB V -4 0 • I N ST A L L A TI O N IN S T R UC T I O NS Figure 17 Step 6. Connect the Gas Line All codes require a shut-off valve mounted in the supply line. The orientation of the shut- off valve should face the front.
S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S T urn on gas supply and test for gas leaks, us - ing a gas leak test solution (also referred to as bubble leak solution).
S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S W ARNING • DO NOT attempt to install the logs until the appliance installation has been completed, the gas line connected and tested for leaks and the initial burner operation has been checked out.
S U PE R I O R ® B- V E N T G A S F I R E PL A C E S • MO D E L S S L B V - 35 , S LB V -4 0 • I N ST A L L A TI O N IN S T R UC T I O NS SLBV-35 LOG PLACEMENT INSTRUCTIONS Figure 23 Left Rear Brackets Step 1 Right Rear Bracket Glowing Embers (Do not place Glowing Embers over burner slots.
SLBV-40 LOG PLACEMENT INSTRUCTIONS Figure 24 Left Rear Log Right Rear Log Ember Chunk Left Front Log Right Front Log 5 4 2 3 1 SLBV Firebox Accessories/Parts Cat.
S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S Only doors certified with the appliance shall be used. Seules des portes certifiées pour cet appareil doivent être utilisées.
S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S Main Burner Factory Air Shutter Opening Setting - Inches (millimeter) Model Nat.Gas Propane Gas S LBV -35 1/ 32 (0.
pull the switch/bracket assembly (with low voltage wires attached) through the side panel slot into the rebox. 8 - Replace the switch, if necessar y .. 9 - Reinstall the scoop and lintel. 10 - Reinstall the glass enclosure panel and control compartment access panel.
Step 12. Install Hood NOTE: All models must have a hood installed prior to operating. Refe r to Figure 30 . Instal l hood by sliding it into the slots on the lower edge of the cabinet top . Step 13. Finishing Requirements Wall Details Complete finished interior wall.
S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S 24 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE.
Millivolt SIT Systems Propane Gas to Natural Gas Conversion Kits Models Catalog No. SLBV-35 H8271 SLBV-40 H7675 Millivolt SIT Systems Natural Gas T o Propane Gas Conversion Kits Models Catalog No. SLBV-35 H8270 SLBV-40 H7673 Electronic DEXEN Systems Propane Gas T o Natural Gas Conversion Kits Models Catalog No.
Electronic Appliances Ste p 8. Dexen Electronic V alves: Refer to Figure 34 and the instructions pro- vided with the kit. a. Remove and discard the two pres- sure regulator mounting screws. b. Remove the pressure regulator and diaphragm. c. Discard all removed components.
Notes S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S 27 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE.
Printed in U.S.A. © 2010 Lennox Hearth Products P/N 506009-02 Rev . B 06/2011 Lennox Hearth Products reser ves the right to make changes at any time, without notice, in design, materials, specications, prices and also to discontinue colors, styles and products.
An important point after buying a device Superior SLBV-40PM (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Superior SLBV-40PM yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Superior SLBV-40PM - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Superior SLBV-40PM you will learn all the available features of the product, as well as information on its operation. The information that you get Superior SLBV-40PM will certainly help you make a decision on the purchase.
If you already are a holder of Superior SLBV-40PM, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Superior SLBV-40PM.
However, one of the most important roles played by the user manual is to help in solving problems with Superior SLBV-40PM. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Superior SLBV-40PM along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center