DIRECT VENT DT-400 AND DR-400

MODELS
tlo villi M
cin o rtc elE
sle d o M N M C 0 0 4 - T D N E C 0 0 4 - T D P M C 0 0 4 - T D P E C 0 0 4 - T D N M C 0 0 4 - R D N E C 0 0 4 - R D P M C 0 0 4 - R D P E C 0 0 4 - R D
RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
OTL Report No. 116-F-17-4
POUR VOTRE SÉCURITÉ: Ne pas entreposer ni utiliser d'essence ni d'autre vapeurs ou liquides inflammables dans le voisinage de cet appareil ou de tout autre appareil.
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors or liquids in the vicin- ity of this or any other appliance.
FOR YOUR SAFETY: What to do if you smell gas:
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
L'installation et service doit être exécuté par un qualifié installeur, agence de service ou le fournisseur de gaz.


Ne pas se servir de cet appareil s'il a été plongé dans l'eau, complètement ou en partie. Appeler un technicien qualifié pour inspecter l'appareil et remplacer toute partie du système de contrôle et toute commande qui ont été plongés dans l'leau.
Appliances with electronic systems will be fit- ted with the electronic valve shown in Figure 3. Familiarize yourself with the differing controls for the valve your appliance uses.
Test gage connections are provided on the front of the millivolt gas control valve (identi- fied OUT for the manifold side and IN for inlet pressure. A ¹⁄₈" NPT test gage connection is provided on the electronic gas control valve adjacent to the outlet to the main burner.
Minimum inlet gas pressure to these appliances is 5.0 inches water column (1.24 kPa) for natural gas and 11 inches water column (2.74 kPa) for propane for the purpose of input adjustment.
Drop Down Control Compartment Access Panel
Maximum inlet gas supply pressure to these appliances is 10.5 inches water column (2.61 kPa) for natural gas and 13.0 inches water column (3.23 kPa) for propane.
Sit and Honeywell Millivolt Gas Valve Showing Piezo Ignitor Location (Each Unit is Equipped with
Only One of these Gas Valves)
The appliance must be isolated from the gas supply piping system (by closing its individual manual shut-off valve) during any pressure test- ing of the gas supply piping system at test pressures equal to or less than ¹⁄₂ psig (3.5 kPa).
Appliance operation may be controlled through a remotely located optional wall switch. Sepa- rate switches may provide independent con- trol for the remote controlled fireplace opera- tion (optional equipment). In lieu of remote or remote wall switch operation, the appliance must be operated directly through the controls located on the front of the valve located within the control compartment located behind the hinged drop down panel below the appliance front glass enclosure panel, Figure 1.
To light millivolt appliances refer to the detailed lighting instructions found in both English and French on pages 12 and 13 of these instruc- tions respectively. Millivolt appliance lighting instructions may also be found on the pull out lighting instruction labels attached to the gas control valve. Refer to Figure 2 to locate the appropriate location for the piezo ignitor used with your appliance.
The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at pressures in excess of ¹⁄₂ psig (3.5 kPa).
These appliances must not be connected to a chimney or flue serving a separate solid fuel burning appliance.
Millivolt appliances may be fitted with an op- tional ON/OFF Rocker Switch for appliance ON/ OFF control. The optional ON/OFF Rocker switch will be installed at either the right or the left side of the Piezo Ignitor on the Piezo Bracket, just beneath the valve. Once the pilot is lighted, the ON/OFF rocker switch will control the appliance ON/OFF operation. To operate: Toggle the switch between its ON and OFF positions.
Any safety guard or screen removed for servic- ing the appliance must be replaced prior to operating the appliance.
The gas controls can be found within the con- trol compartment behind the hinged drop-down control compartment access panel comprising the lower front face of the appliance below the front glass enclosure panel.
To open the control compartment access panel, actuate the spring loaded magnetic catches se- curing the door by gently depressing the outer top corners of the door until the catches "pop" the door free, allowing it to swing out and down to open. Once the control compartment door is opened, complete access to the gas control valve and its related controls is attainable.
If your millivolt appliance is equipped with an optional remote wall switch or remote control kit and the pilot is lit, the appliance main burner may be turned on and off with the wall switch or remote control.
To light electronic appliances refer to the de- tailed lighting instructions found in both En- glish and French on pages 14 and 15 of these instructions respectively. Electronic appliance lighting instructions may also be found on the pull out lighting instruction labels at- tached to the gas control valve. If your elec- tronic appliance is equipped with an optional remote wall switch or remote control kit the appliance main burner may be turned on and off with the wall switch or remote control.
To ease door closure, depress the catches to place them in their retracted position until they stay there, then close the door.
Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea. If you have these signs, obtain fresh air immedi- ately. Turn off the gas supply to the appliance and have it serviced by a qualified profes- sional, as it may not be operating correctly.
Operation of millivolt and electronic gas control systems are different. Before lighting and op- erating your appliance determine if you have a millivolt or electronic appliance. Refer to Fig- ure 1 to access the control compartment. Mil- livolt appliances will be fitted with the gas control valve shown in Figure 2.

If your electronic appliance is not equipped with a wall switch or remote control, the main burner must be turned off and on with the gas control switch. Toggle the switch from ON to OFF to operate the main burner .
ON
OFF
IN PSI
Electronic Gas Control Valve
Variable Flame Height Adjustment ( Millivolt Appliances only)
Manifold Pressure Port · ON/OFF Switch · Inlet Pressure Port

Annually (Before the onset of the Burning Season)
Maintenance Task Accomplishing Person Procedure
Inspecting/Cleaning Burner, Logs and Controls
Inspect valve and ensure it is properly operat- ing. Check piping for leaks. Vacuum the control compartment, fireplace logs and burner area.
Check Flame Patterns and Flame Height
Refer to Figure 7 on page 7 and verify the flame pattern and height displayed by the appliance conforms to the picture. Flames must not impinge on the logs.
Inspecting/Cleaning Pilot and Burner
Refer to Figure 8 on page 7 (Millivolt) or Figure 9 on page 7 (Electronic). Remove any surface build-up on pilot and burner assem- bly. Wipe the pilot nozzles, ignitor/flame rod and hood. Ensure the pilot flame engulfs the flame sensor as shown.
Inspect the vent system at the top and at the base (within the firebox) for signs of blockage or obstruction. Look for any signs of disloca- tion of the vent components.
Perform the appropriate appliance checkout procedure detailed in this manual.
Replacing Rockwool Ember Materials
Remove old ember materials and vacuum the screened rockwool placement area. Place new rockwool as described in this document.
Periodically (After the Burning Season)
Maintenance Task Accomplishing Person Procedure
Carefully remove logs, Rockwool and volcanic stone if used. Vacuum out interior of the firebox. Clean firebox walls and log grate. Replace logs, Rockwool and volcanic stone as detailed in this manual.
Check Flame Patterns and Flame Height
Refer to Figure 7 on page 7 and verify the flame pattern and height displayed by the appliance conforms to the picture. Flames must not impinge on the logs.
Inspect the vent system at the top and at the base (within the firebox) for signs of blockage or obstruction. Look for any signs of disloca- tion of the vent components.
Cleaning Front Glass Enclosure Panel
Clean as necessary following the directions provided in this manual. DO NOT TOUCH OR ATTEMPT TO CLEAN GLASS WHILE HOT.

Front Glass Enclosure Panel, Removal and Installation.
Refer to Figure 5 and remove the front glass enclosure panel as follows:
Flame Appearance and Sooting
Proper flame appearance is a matter of taste. Generally most people prefer the warm glow of a yellow to orange flame. Appliances operated with air shutter openings that are too large will exhibit flames that are blue, transparent and much smaller than designed. These weak, blue and transparent flames are termed anemic. If the air shutter open- ing is too small sooting may develop.
Sooting is indicated by black puffs developing at the tips of very long orange flames. Sooting results in black deposits forming on the logs, appliance inside surfaces and on exterior sur- faces adjacent to the vent termination.
These are direct-vent appliances. They are designed to operate only when the front glass enclosure panel is installed. Generally the front glass enclosure panel should not be removed except to gain access to the compo- nents within the firebox, and the appliance may only be operated without the front glass enclosure panel in place for very brief periods of time during appliance checkout and adjust- ment. Be sure that the flame appearance will be diminished while the front glass enclosure panel is removed.
THE GLASS DOOR OF THIS APPLIANCE MUST ONLY BE REPLACED AS A COMPLETE UNIT AS PROVIDED BY THE MANUFACTURER. DO NOT ATTEMPT TO REPLACE BROKEN, CRACKED OR CHIPPED GLASS SEPARATELY.
Sooting is caused by incomplete combustion in the flames and a lack of combustion air entering the air shutter opening. To achieve a warm yellow to orange flame with an orange body that does not soot, the shutter opening must be adjusted between these two extremes. No smoke or soot should be present. Reposition the logs if the flames impinge on any of them. If the logs are properly positioned and sooting conditions exist, the air shutter opening on the main burner tube should be adjusted. Nor- mally, the more elbows and horizontal runs there are in the vent system, the greater the need for the air shutter to be opened further.
To install the front glass enclosure panel, proceed as follows:
Top Flange Door Frame
ENSURE THAT THE FRONT GLASS PANEL IS IN PLACE AND SEALED DURING ADJUSTMENT.
To adjust the flame, move the adjustment rod (located in the lower control area) up or down to increase or reduce the air shutter opening respectively. Initially, always position the air shutter to the factory setting (the minimum air opening position as shown in Figure 6, on page 7. This can be done by pulling the adjustment rod all the way down.
Burner Adjustments The following paragraphs address burner ad- justment concerns and procedures.

Allow the burner to operate for at least 15 minutes. Observe the flame continuously. If it appears weak or sooty as previously described, adjust the air shutter by pushing or pulling on the adjustment rod until the flame appearance is as desired.
The adjustment rod and associated adjustable air shutter is patented technology. Flame ad- justments can be made quickly and accurately to taste without the need of disassembling the appliance and waiting for 30 minutes after each adjustment.
Proper twig placement is critical to prevent soot- ing. Twigs should be placed in the gaps between the flame peaks and should be positioned so that at no time they impinge the flames.
Remove the replacement rockwool (Glowing Embers) from the packaging and tear into quarter size pieces (Figure 8).
Spread rockwool (nickel-sized pieces) on and along the length of the burner screen. Do not use more than is necessary. To many nickel- sized pieces on the front burner section will cause poor combustion.
Adjustment Rod Down (Minimum air opening
When properly positioned, the rockwool will unevenly cover approximately 85% of the burner screen with no appreciable gaps or openings.

Carefully position the ceramic fiber logs and twigs over the burner according to the follow- ing steps while referring to Figure 7.

Propane models may exhibit a flame pattern that may candle or appear stringy. If this is problematic or persists as the appliance is continually operated, adjust the air shutter closed as described in the previous para- graphs. Operate the appliance for a period of time as the effect diminishes, ensuring that the appliance does not develop sooty flames.
When satisfied that the appliance operates properly, proceed to finish the installation. Leave the control knob in “ON” position and turn the remote switch “OFF.” Close the lower control compartment door.


SIT and Honeywell Millivolt Appliance Checkout
With proper care and maintenance, your ap- pliance will provide many years of enjoy- ment. If you should experience any problem, first refer to the trouble shooting guide in this manual. If problem persists, contact your Lennox distributor.
The pilot flame should be steady, not lifting or floating. Flame should be blue in color with traces of orange at the outer edge.
¹⁄₈" Min (3 mm)
The top ³⁄₈" (10 mm) at the pilot generator (thermopile) and the top ¹⁄₈" min (tip) of the quick drop out thermocouple should be engulfed in the pilot flame. The flame should project 1" (25 mm) beyond the hood at all three ports (Figure 9 - SIT, Figure 10 - Honeywell ).
³⁄₈" Min (9 mm)
With proper care and maintenance, your ap- pliance will provide many years of enjoy- ment. If you should experience any problem, first refer to the trouble shooting guide in this manual. If problem persists, contact your Lennox distributor.
To light the burner, refer to the lighting in- structions on pages 12 and 13 for Honeywell and SIT millivolt gas valves).
The wiring diagrams are provided here for reference purposes only (Figures 12, 13 and 14 on page 9). This information is also pro- vided on schematics found on pullout lighting instruction labels located within the control compartment attached to the gas control valve.
To light the burner, turn ‘ON’ the optional remote wall switch and turn the gas control switch to the “ON” position. Ensure the ignitor lights the pilot. The pilot flame should engulf the flame rod as shown in Figure 11.
³⁄₈" Min (9 mm)
3/8 To 1/2 Inch (9 mm to 13 mm)

Electronic Wiring Diagram (Honeywell) Showing the Blower Wiring for the Optional
*ON/OFF Switch (Integral with Gas Valve)
*Leave the ON/OFF switch, which is integral with the gas valve, in the ON position.
120 VAC. BK
G
BK
IGNITER
W
R
BL
OPT BLOWER
G
White Wire To Opposite
B
Transf.
Hot side of Outlet
R
WH
BK
OPTIONAL APPLIANCE-MOUNTED ON/OFF SWITCH
OR OPTIONAL WALL SWITCH
OR OPTIONAL THERMOSTAT OR OPTIONAL REMOTE RECEIVER
Factory Wired Field Wired
Decorative Volcanic Stone 80L42 FDVS Bag of Rockwool 88L53 FGE
The decorative volcanic stone, Model FDVS, can be used to enhance the look of your appli- ance. Decorative volcanic stone is standard with this appliance. Order model FDVS for replacement of stone when needed. Spread the decorative volcanic stone evenly around the bottom of the firebox.
Bag of Rockwool (Glowing Embers)
The rockwool, Model FGE, can be used to enhance the look of your appliance. Rockwool is standard with this appliance. Order model FGE for replacement of rockwool when needed. Place the rockwool on the burner screen as described in the section in this manual entitled Glowing Ember Placement on page 7.



Remote Control System (Standard) H0249 RCL
Arch Door Kits Brass Finish 99L56 ADK-4B Brushed Stainless Finish 99L57 ADK-4BS
Remote Control System (Deluxe) H0251 RCL-T
The Model RCL (Standard) Remote Control System, features a simplistic on/off control function for the fireplace. This model includes a hand-held transmitter, a remote receiver with wall-mount coverplate and all hardware required to install the unit. The remote re- ceiver can be wall or hearth mounted.
The Model RCL-T (Deluxe) Remote Control System has all of the features of the standard system along with an added easy to read LCD screen which presents access to many en- hancements, including; battery power level in- dicator, timer, mode of operation, thermostatic display including room temperature in either metric of English units, flame indicator and clock. Fully programmable, the Model RCL-T allows for virtual command over nearly all op- erational and temperature variables, using the hand held remote control transmitter.
Arch door kits are available for the DT-400 and DR-400 Series. This kit is easy to install and does not require hardware to attach it to the standard door frame. This kit can be retrofitted to previously installed DT-400 and DR-400 Series appliances. The decorative arch kits can not be used in conjunction with the screen panel kit.
The transmitter has ON and OFF functions that are activated by pressing either button on the face of the transmitter. When a button on the transmitter is pressed, a signal light illuminates briefly to verify that a signal has been sent.
The Model RCL is designed to operate with all millivolt ignition systems, as well as electronic ignition systems. It may be installed with use for either natural or propane gas appliances. The RCL offers ease of installation and allows you to execute on-off commands to the fire- place effortlessly with one simple motion.
The Model RCL-T (Deluxe) remote control sys- tem is installed in the same manner as the standard system, may be operated with elec- tronic and millivolt systems with either natural or propane gas. The RCL-T comes complete with detailed operating instructions.
The Model RCL comes complete with detailed operating instructions.
Brickade Liner Kits Top Vent 99L53 BLK-4T Rear Vent 99L54 BLK-4R
One of the most beautiful enhancements you can make to the DT-400 and DR-400 Series is the addition of brickade liners. The brickade liner kits include tan stamped sheetmetal pan- els for the rear and side walls of the firebox. The panels have brick-like features in relief. To install the panels, simply position them against the firebox walls and screw them in place. These kits can be retrofitted into previously installed appliances. Purchase the BLK-4T for top vented appliances and the BLK-4R for rear vented appliances.
Rocker Switch Kit 80L41 FRS
Screen Panel Kit 99L55 SPK-4
An optional rocker switch kit can be installed directly on all DT-400 and DR-400 Series appli- ances to provide for On and Off operation in lieu of a wall switch. This kit is designed to install in the lower control compartment out of view and is perfect for use in high volume areas such as lobbies and model homes where limited access to the appliance On/Off switch is desirable. This kit can be retrofitted to previously installed appliances and may be temporarily installed in place of other switch circuitry.
An optional screen panel can be installed on the DT-400 and DR-400 Series door. This screen panel is easy to install. This kit can be retrofitted to previously installed appliances. The screen panel kit can not be used in conjunction with either of the arch door kits or door frame kits.

Square Log Rack 99L59 DLR-4
Brass Finish Hood Kit 99L64 HK-4B Brushed Stainless Finish Hood Kit 99L65 HK-4BS
The decorative log rack provides the look of a wrought iron log rack. The rack installs easily in front of the log set with two screws. This kit can be retrofitted to previously installed DT- 400 and DR-400 units.
Attractive hoods are available in two styles to be used on the DT-400 and DR-400 Series appliances. These hoods are designed to be fitted to the face of the appliance. In addition to providing an aesthetically pleasing appear- ance to your appliance installation, the hood reduces heat effects to decorative mantles and finish materials located above the fireplace opening. The hood kit replaces the standard hood that comes with these appliances and snaps into place. These kits can be retrofitted to previously installed appliances.
Complete Louver Kits Brass Finish 99L60 LK-4B Brushed Stainless Finish 99L61 LK-4BS
Decorative louvers are available for use with all DT-400 and DR-400 Series direct vent lou- vered-face appliances. These louvers are de- signed to replace the standard black louvers that are provided with the appliance. These louver kits include six (6) finished louvers. They can be retrofitted to previously installed appliances.
Forced Air Blower Kits -Single Speed 80L84 FBK-100 -Variable Speed 80L85 FBK-200 -Unit Mountable 80L86 FBK-250
The FBK-100 blower provides for a constant velocity forced air circulation feature for your appliance. The FBK-200 assembly with variable speed wall switch provides a forced air circula- tion feature for your appliance. The FBK-250 comes complete with a unit mountable switch operating system.
Door Frame Kits - 4 piece (shown) Brass Finish 99L62 DFK-4B Brushed Stainless Finish 99L63 DFK-4BS Door Frame Kits - 2 piece Brass Finish 17M28 DTK-4B Brushed Stainless Finish 17M29 DTK-BS
Radiant Panel Kit 99L58 CFPK-4
Door Frame Kits
Clean face panel kits are available to convert the standard louvered appliances to clean face models more suited for finishing around the firebox opening with non-combustible materi- als such as tile.
Decorative door frame kits are available for use with these appliances. The DFK (four- piece kit) is de- signed to attach directly to the front face of the appliance at its extreme edges; the DTK (two-piece kit) at the front face's extreme top and bottom edges. These kits provide a picture frame finish for the appliance. The door frame kit can be retrofitted onto previously installed appliances.
Touch-Up Paint Kit (Black) 90L73 FTPK-B Touch-Up Paint Kit (Tan) 98K67
Repair of minor scratches and discoloration of the appliance black painted surfaces may be accomplished with the touch-up paint kit.
(FBK-200 Models Only)

A. This appliance has a pilot which must be lighted with a piezo
ignitor. When lighting the pilot, follow these instructions exactly.
B. BEFORE OPERATING smell all around the appliance area for
gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or an explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
LIGHTING INSTRUCTIONS 1. STOP! Read the safety information above on this page.
O
T
O
F
F
MILLIVOLT GAS VALVE
H
P
O
O
N
PIEZO IGNITOR
OUT IN
TPTH TP TH
SIT MILLIVOLT GAS VALVE
H
O
F
F
P
W
T
O
N
O
P
T
O
PIEZO IGNITOR
unless the knob is pushed in slightly. Do not force.
it

A. When lighting the appliance, follow these instructions
exactly.
for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
C. Use only your hand to turn the gas control lever. Never
use tools. If the lever will not turn by hand, do not try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or an explosion.
D. Do not use this appliance if any part has been under
water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
ON
OFF
IN PSI
ON/OFF Switch · Front View

POSSIBLE CAUSES
A. Defective ignitor
Check for spark at electrode and pilot; if no spark and electrode wire is properly connected, replace ignitor.
(no spark at electrode).
B. Defective or misaligned electrode
Using a match, light pilot. If pilot lights, turn off pilot and trigger the ignitor button again. If pilot lights, an improper gas mixture caused the bad lighting and a longer purge period is recommended. If pilot will not light – check gap at electrode and pilot – should be ¹⁄₈" to have a strong spark. If gap measures ¹⁄₈", replace pilot (Figure 9 on page 8- SIT, Figure 10 on page 8- Honeywell ).
at pilot (spark at electrode).
C. Gas supply pressure errant.
Check inlet gas pressure. It should be within the limits as marked on the rating plate.
D. Pilot orifice plugged.
Clean or replace pilot orifice.
A. Defective pilot generator (thermocouple).
Check pilot flame, it must impinge on thermocouple (Figure 9 on page 8- SIT, Figure 10 on page 8- Honeywell ). Clean and/or adjust pilot for maximum flame impingement on thermocouple. Ensure that the connection between the valve and thermocouple are tight and secure.
A. Wall switch or wires defective.
Check wall switch and wires for proper connections. Jumper wire across terminals at wall switch, if burner comes on, replace defective wall switch. If okay, jumper wires across wall switch wires at valve, if burner comes on, wires are faulty or connections are bad.
B. Thermopile may not be generating
Check thermopile with millivolt meter. Take reading at thermo- pile terminals of gas valve. Should read 325 millivolts mini- mum with optional wall switch “OFF.” Replace faulty thermo- pile if reading is below specified minimum.
sufficient millivoltage.
C. Plugged burner orifice.
Check burner orifice for stoppage and remove.
A. Pilot flame may be too low or
Clean and/or adjust pilot flame for maximum flame impinge- ment on thermocouple (Figure 9 on page 8- SIT, Figure 10 on page 8- Honeywell).
blowing (high) causing the pilot/ valve safety to drop out.

Note: Before troubleshooting, be sure that the appliance main line gas shut-off valve, the gas control valve and the wall switch are in the “ON” position.
A. Faulty Valve System.
See Below.
B. “OFF/ON” or wall switch
Disconnect the two black wires from the wire nuts. Test switch(s) for continuity with a multimeter. If continuity is not indicated, switch(s) is defective and must be replaced.
defective.
A. Burner orifice plugged.
Check main burner orifice(s) for stoppage. Clean or replace.
B. Obstructed vent system.
Check vent system for obstructions.
YES
End View Of Control Harness Connector
YES 1
NO
Check For Damaged Or Missing Terminals In Connector
YES
YES
When Measured Voltage At Connections, Use Care To Assure Terminals Are Not Damaged.

No. DESCRIPTION Part No. Qty. Part No. Qty.
Gas Fireplace Assembly –
. o N N O IT P I R C S E D la r uta N e n a p o r P
. o N tr a P .yt Q . o N tr a P .yt Q
.0 2 TI S - e vla V s a G 1 0 7 0 K 3 4 1 1 0 3 5 J 8 8 1
.1 2 retin gI o z eiP 1 0 6 8 K 0 1 1 1 0 6 8 K 0 1 1
.2 2 ylb m e s s A toliP 1 0 7 1 L 9 6 1 1 0 8 1 L 9 6 1
.3 2 r otare n e G toliP 1 0 9 7 J 0 6 1 1 0 9 7 J 0 6 1
.4 2 elp u o c o m re h T 1 0 7 5 L 4 7 1 1 0 7 5 L 4 7 1
.5 2 e b u T toliP 1 0 6 5 L 4 7 1 1 0 6 5 L 4 7 1
.6 2 elb a C d n A e d o rtc elE 1 0 8 5 L 4 7 1 1 0 8 5 L 4 7 1 .7 2 dleih S toliP 6 0 7 2 9 - B L 1 6 0 7 2 9 - B L 1
. o N N O IT P I R C S E D la r uta N e n a p o r P
. o N tr a P .yt Q . o N tr a P .yt Q.0 3 e vla V s a G 1 0 6 8 L 2 8 1 1 0 7 8 L 2 8 1
.1 3 ylb m e s s A toliP 1 0 0 7 L 7 6 1 1 0 0 7 L 7 6 1
.2 3 r otare n e G toliP 1 0 9 7 J 0 6 1 1 0 9 7 J 0 6 1
.3 3 elp u o c o m re h T 1 0 7 6 L 7 6 1 1 0 7 6 L 7 6 1
.4 3 e b u T toliP 1 0 8 6 L 7 6 1 1 0 8 6 L 7 6 1
.5 3 elb a C d n A e d o rtc elE 1 0 7 8 L 7 6 1 1 0 7 8 L 7 6 1
.6 3 retin gI o z eiP 1 0 9 8 M 4 2 1 1 0 9 8 M 4 2 1 .7 3 dleih S toliP 6 0 7 2 9 - B L 1 6 0 7 2 9 - B L 1
No. DESCRIPTION Part No. Qty. Part No. Qty.



The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.
LHP 1110 West Taft Avenue Orange, CA 92865
Printed in U.S.A. © 2002 by LENNOX HEARTH PRODUCTS P/N 725,023M REV. J 11/2004