1 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. INST ALLA TION INSTRUCTIONS ST ANDARD SERIES 36" B-VENTED GAS APPLIANCES P/N 700,003M REV. H 05/2004 Millivolt Models Electronic Models B-40RMN B-40REN B-40RMP B-40REP RET AIN THESE INSTRUCTIONS FOR FUTURE REFERENCE WH Report No.
2 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. TABLE OF CONTENTS Introduction ..................................... page 2 General Information ......................... page 2 Location .......................................... page 3 Clearances .
3 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea.
4 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Venting Gas Vent Rule – Gas vent caps are not permit- ted within 8 feet (2.4 mm) of a vertical wall or similar obstruction.
5 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. A 38 ¹⁄₂ " 978 mm B 33 ³⁄₄ " 857 mm C 28 ³⁄₁₆ " 716 mm D 14" 356 mm E 55" 1397 mm F 27 ¹⁄₂ " 699 .
6 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 10 Note: Refer to the vent manufacturers installa- tion instructions for variations of venting tech- niques. If common venting of several units is contemplated, it should be discussed with an architect and the local Building Department.
7 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 13 Figure 14 Figure 12 Figure 15 Secure all joints tightly using appropriate tools and sealing compounds (ensure propane resis- tant compounds are used in propane applica- tions). Turn on gas supply and test for gas leaks using a soapy water solution.
8 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. WARNING: DO NOT REMOVE THE AC- TUATOR ARM LOCKING SCREW UNLESS THE COMPLETE OUTSIDE AIR VENT SYS- TEM HAS BEEN INSTALLED IN ACCOR- DANCE WITH THE DETAILED INSTRUC- TIONS PROVIDED WITH THE KIT.
9 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 19 Figure 20 When first lighting the appliance, it will take a few minutes for the line to purge itself of air. Once purging is complete, the pilot and burner will light and operate as indicated in the in- struction manual.
10 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. When satisfied that the appliance operates prop- erly, proceed to finish the installation. Leave the control knob/lever in “ ON ” position and turn the remote switch “ OFF. ” Replace the refractory access panel.
11 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. INSTALLATION ACCESSORIES The following accessory items are available for use in the installation of this appliance. Outside Air Kits Models FOAK-4 and FOAK-4LD Outside Air kits are available with duct (FOAK-4) and without duct (FOAK-4LD) for use if outside combustion air is required or desired.
12 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. In Canada THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CAN1-B149.1 AND .2 INSTALLATION CODE.
13 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 29 Pilot Orifice Step 6. All Millivolt Systems – Attach ma- nometer to the manifold side pressure test fitting and verify manifold pressure reads 3.5 inches water column (0.87 kPa) for natural gas, and 10.
14 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE..
15 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE..
16 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Printed in U.S.A. © 2002 by Lennox Hearth Products P/N 700,003M REV. H 05/2004 LHP 1110 West Taft Avenue • Orange, CA 92865 The manufacturer rese.
An important point after buying a device Superior B-40RMN (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Superior B-40RMN yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Superior B-40RMN - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Superior B-40RMN you will learn all the available features of the product, as well as information on its operation. The information that you get Superior B-40RMN will certainly help you make a decision on the purchase.
If you already are a holder of Superior B-40RMN, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Superior B-40RMN.
However, one of the most important roles played by the user manual is to help in solving problems with Superior B-40RMN. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Superior B-40RMN along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center