Instruction/ maintenance manual of the product P8700CFCHEC Stovax
Go to page of 33
STUDIO C o n v e n t i o n a l F l u e Instructions for Use, Installation and Servicing For use in GB, IE (Great Britain and Eire) PR0957 Studio (Issue 3 - January 2008) IMPORTANT Do not attempt to burn rubbish in this appliance. This appliance must only be operated with the glass door secured firmly in position.
2 COVERING THE FOLLOWING MODEL: STUDIO 1 CONVENTIONAL FLUE: 8700CFCHEC 8701CFCHEC P8700CFCHEC P8701CFCHEC PAGE APPLIANCE COMMISSIONING CHECKLIST 3 USER INSTRUCTIONS 4 INSTALLATION INSTRUCTIONS 8 Techn.
3 FLUE CHECK PASS FAIL 1. Flue is correct for appliance 2. Flue flow test 3. Spillage test GAS CHECK 1. Gas soundness & let by test 2. Standing pressure test mb 3. Appliance working pressure (on High Setting) mb NB All other gas appliances must be operating on full 4.
4 USER INSTRUCTIONS 1. GENERAL 1.1 A competent person must carry out installation and servicing. 1.2 In all correspondence, please quote the appliance type and serial number, which can be found on the data badge located on a plate inside the controls compartment 1.
5 USER INSTRUCTIONS Turning the Studio Off 2.
6 USER INSTRUCTIONS EMERGENCY SHUT OFF If the batteries fail during use of the fire, move the switch to .
7 USER INSTRUCTIONS 5. ARRANGEMENT OF FUEL BED 5.1 If you need to replace pebbles or refill the tray, make sure the pebbles are flattened so they are level with the rim of the tray. TAKE CARE NOT TO SPILL PEBBLES INTO THE PILOT AREA ONLY PEBBLES SUPPLIED BY GAZCO CAN BE USED IN THIS FIRE.
8 INSTALLATION INSTRUCTIONS TECHNICAL SPECIFICATION COVERING THE FOLLOWING MODELS: STUDIO 1 CF: STUDIO 2 CF: 8700CFCHEC 8701CFCHEC P8700CFCHEC P8701CFCHEC Model Gas CAT. Gas Type Working Pressure Aeration Injector Gas Rate m 3 /h Input kW (Gross) Country High Low Studio 1 CF 12H Natural G20 20mbar 6 x 10 390 0.
9 INSTALLATION INSTRUCTIONS TECHNICAL SPECIFICATION This appliance has been certified for use in countries other than those stated. To install this appliance in these countries, it is essential to obtain the translated instructions and in some cases the appliance will require modification.
10 INSTALLATION INSTRUCTIONS TECHNICAL SPECIFICATION 2 Steel Profil Bauhaus STEEL FRAME DIMENSIONS Dimension Studio 1 Studio 2 A 1120 1350 B 675 675 C 646 846 D 320 320 E 177 177 F 237 237 G 25 25 PROFIL FRAME DIMENSIONS Dimension Studio 1 Studio 2 A 846 1046 B 520 520 C 750 950 D 424 424 E 48 48 F 48 48 G 12.
11 INSTALLATION INSTRUCTIONS SITE REQUIREMENTS 1. FLUE AND CHIMNEY REQUIREMENTS WHEN INSTALLING A FLUE SYSTEM PLEASE REFER TO THE MANUFACTURER’S INSTRUCTIONS.
12 INSTALLATION INSTRUCTIONS SITE REQUIREMENTS without a liner, there must be a minimum debris collection area, Diagram 1b AR2006 1b 5.
13 IMPORTANT: .
14 INSTALLATION INSTRUCTIONS INSTALLATION 3 AR1963 3. STUD WORK INSTALLATION THERE IS AN OPTIONAL DUCT KIT, CODE No. 8572 WHICH CAN BE FITTED AT THE SAME TIME AS THE APPLIANCE INSTALLATION.
15 INSTALLATION INSTRUCTIONS INSTALLATION 7 AR1903 .
16 INSTALLATION INSTRUCTIONS INSTALLATION 13 AR1887 wall plate Because of the high temperatures this fire achieves, it is advisable to use marble slips or similar material between the appliance and the plasterboard Never use a one-piece slip as expansion (even cracking) can occur.
17 INSTALLATION INSTRUCTIONS INSTALLATION 20 AR1862 .
18 INSTALLATION INSTRUCTIONS INSTALLATION 23 AR1965 .
19 INSTALLATION INSTRUCTIONS INSTALLATION .
20 .
21 INSTALLATION INSTRUCTIONS INSTALLATION 36 AR1862 5.5 Using the allen key provided: .
22 7. COMMISSIONING 7.1 Check the flame picture 7.2 Check the gas pressure .
23 IGNITION FUNCTIONAL CHECK 1 (e.
24 SERVICING INSTRUCTIONS FAULT FINDING CHARTS .
25 AR1862 3 .
26 SERVICING INSTRUCTIONS REPLACING PARTS 4. GLASS WINDOW 4.1 Remove the two clips and brackets from either side of the frame, Diagram 5 5 AR1864 .
7. MAIN CONTROL ASSEMBLY 7.1 To access the main control assembly, first remove: .
28 SERVICING INSTRUCTIONS REPLACING PARTS 10. GAS VALVE 10.1 To change the gas valve: .
29 SERVICING INSTRUCTIONS REPLACING PARTS 13. MAIN INJECTOR .
30 SERVICING INSTRUCTIONS REPLACING PARTS 17. PRESSURE AND LEAK TESTING THE APPLIANCE 14.1 Follow Section 7, Main Control Assembly, 7.1 and 7.2 .
31 SERVICING INSTRUCTIONS REPLACING PARTS 18. SHORT SPARES LIST Studio 1 CF Studio 2 CF COMPONENT NG LPG NG LPG PILOT PI0036 PI0037 PI0036 PI0037 MAIN INJECTOR IN0028 IN0040 IN0029 IN0041 BURNER ASSEM.
32 SERVICE RECORDS 1ST SERVICE Date of Service:........................................................................... Next Service Due:....................................................................... Signed:................................
Gazco Limited, Osprey Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7JG Tel: (01392) 261999 Fax: (01392) 444148 E-mail: info@gazco.com A member of the Stovax Group.
An important point after buying a device Stovax P8700CFCHEC (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Stovax P8700CFCHEC yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Stovax P8700CFCHEC - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Stovax P8700CFCHEC you will learn all the available features of the product, as well as information on its operation. The information that you get Stovax P8700CFCHEC will certainly help you make a decision on the purchase.
If you already are a holder of Stovax P8700CFCHEC, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Stovax P8700CFCHEC.
However, one of the most important roles played by the user manual is to help in solving problems with Stovax P8700CFCHEC. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Stovax P8700CFCHEC along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center