Switch 4400 (3C17203) Switch 4400 (3C17204) Switch 4400 PWR (3C17205) Switch 4400 SE (3C17206) Switch 4400 FX (3C17210)

Part No. DUA1720-3AAA07 Published March 2004

3Com Corporation 350 Campus Drive Marlborough, MA 01752-3064
Copyright © 2004, 3Com Corporation. All rights reserved. No part of this documentation may be reproduced in any form or by any means or used to make any derivative work (such as translation, transformation, or adaptation) without written permission from 3Com Corporation.
3Com Corporation reserves the right to revise this documentation and to make changes in content from time to time without obligation on the part of 3Com Corporation to provide notification of such revision or change.
3Com Corporation provides this documentation without warranty, term, or condition of any kind, either implied or expressed, including, but not limited to, the implied warranties, terms or conditions of merchantability, satisfactory quality, and fitness for a particular purpose. 3Com may make improvements or changes in the product(s) and/or the program(s) described in this documentation at any time.
If there is any software on removable media described in this documentation, it is furnished under a license agreement included with the product as a separate document, in the hard copy documentation, or on the removable media in a directory file named LICENSE.TXT or !LICENSE.TXT. If you are unable to locate a copy, please contact 3Com and a copy will be provided to you.
If you are a United States government agency, then this documentation and the software described herein are provided to you subject to the following:
All technical data and computer software are commercial in nature and developed solely at private expense. Software is delivered as “Commercial Computer Software” as defined in DFARS 252.227-7014 (June 1995) or as a “commercial item” as defined in FAR 2.101(a) and as such is provided with only such rights as are provided in 3Com’s standard commercial license for the Software. Technical data is provided with limited rights only as provided in DFAR 252.227-7015 (Nov 1995) or FAR 52.227-14 (June 1987), whichever is applicable. You agree not to remove or deface any portion of any legend provided on any licensed program or documentation contained in, or delivered to you in conjunction with, this User Guide.
Unless otherwise indicated, 3Com registered trademarks are registered in the United States and may or may not be registered in other countries.
3Com, the 3Com logo and SuperStack are registered trademarks of 3Com Corporation.
Intel and Pentium are registered trademarks of Intel Corporation. Microsoft, MS-DOS, Windows, and Windows NT are registered trademarks of Microsoft Corporation. Novell and NetWare are registered trademarks of Novell, Inc. UNIX is a registered trademark in the United States and other countries, licensed exclusively through X/Open Company, Ltd.
IEEE and 802 are registered trademarks of the Institute of Electrical and Electronics Engineers, Inc.
Netscape Navigator is a registered trademark of Netscape Communications.
JavaScript is a trademark of Sun Microsystems.
All other company and product names may be trademarks of the respective companies with which they are associated.
It is the policy of 3Com Corporation to be environmentally-friendly in all operations. To uphold our policy, we are committed to:
Establishing environmental performance standards that comply with national legislation and regulations.
Conserving energy, materials and natural resources in all operations.
Reducing the waste generated by all operations. Ensuring that all waste conforms to recognized environmental standards. Maximizing the recyclable and reusable content of all products.
Ensuring that all products can be recycled, reused and disposed of safely.
Ensuring that all products are labelled according to recognized environmental standards.
Improving our environmental record on a continual basis.
End of Life Statement
3Com processes allow for the recovery, reclamation and safe disposal of all end-of-life electronic components.
3Com products do not contain any hazardous or ozone-depleting material.
Environmental Statement about the Documentation
The documentation for this product is printed on paper that comes from sustainable, managed forests; it is fully biodegradable and recyclable, and is completely chlorine-free. The varnish is environmentally-friendly, and the inks are vegetable-based with a low heavy-metal content.
This product contains encryption and may require U.S. and/or local government authorization prior to export or import to another country.
Regulated Materials Statement

Before You Start 7 Release Notes 7 About Your CD-ROM 8 Conventions 8 Related Documentation 9 Accessing Online Documentation 10 Documentation Comments 10 Product Registration 11
About the Switch 4400 14 Summary of Hardware Features 14 Switch 4400 — Front View Detail 15 10BASE-T/ 100BASE-TX Ports 16 100BASE-FX Ports 16 LEDs 17 Switch 4400 — Rear View Detail 19 Power Socket 19 Redundant Power System Socket 19 Console Port 19 Expansion Module Slots 19 Default Settings 20
Package Contents 24 Choosing a Suitable Site 24 Rack-mounting 25 Placing Units On Top of Each Other 27 Stacking Units 27

How To Stack Units 27 Rules For Stacking Units 28 The Power-up Sequence 30 Powering-up the Switch 4400 30 Checking for Correct Operation of LEDs 30 Connecting a Redundant Power System 30 Using Power over Ethernet 31 Choosing the Correct Cables (Switch 4400, 4400 SE and 4400 PWR) 32 Choosing the Correct Cables (Switch 4400 FX) 33
Setting Up Overview 36 IP Configuration 37 Preparing for Management 38 Manually Configuring IP Information 39 Connecting to a Front Panel Port 39 Connecting to the Console Port 42 Viewing Automatically Configured IP Information 46 Using 3Com Network Supervisor 46 Connecting to the Console Port 46 Methods of Managing a Switch 49 Command Line Interface Management 49 Command Line Interface Management using SSH 50 Web Interface Management 50 SNMP Management 50 Setting Up Command Line Interface Management 50 CLI Management via the Console Port 51 CLI Management over the Network 51 Setting Up Command Line Interface Management using SSH 52 Setting Up Web Interface Management 53 Pre-requisites 53 Web Management Over the Network 54 Setting Up SNMP Management 54 Pre-requisites 55 Default Users and Passwords 55 Changing Default Passwords 55

Solving Problems Indicated by LEDs 58 Solving Hardware Problems 59 Solving Communication Problems 62 Solving Software Upgrade Problems 63
Power Cord Set — Japan 65 Important Safety Information 66 L’information de Sécurité Importante 68 Wichtige Sicherheitsinformationen 70
Null Modem Cable 73 PC-AT Serial Cable 73 Modem Cable 74 RJ-45 Pin Assignments 74
Switch 4400 (24-port) and Switch 4400 SE 77 Switch 4400 PWR (24-port) 79 Switch 4400 (48-port) 80 Switch 4400 FX 81
Register Your Product to Gain Service Benefits 83 Purchase Value-Added Services 83 Troubleshoot Online 83 Access Software Downloads 84 Contact Us 84 Telephone Technical Support and Repair 84

R EGULATORY N OTICES

This guide provides all the information you need to install and use the following switches in their default state:
All procedures described in this guide apply to all models except where stated.
The guide is intended for use by network administrators who are responsible for installing and setting up network equipment; consequently, it assumes a basic working knowledge of LANs (Local Area Networks).
Before You Start This section contains information about the documents and CD-ROM that accompany your Switch 4400.
Release Notes The Release Notes provide important information about the current software release, including new features, modifications, and known problems. You should read the Release Notes before installing the Switch in your network.
If the information in the Release Notes differ from the information in this guide, follow the instructions in the Release Notes.

About Your CD-ROM The CD-ROM contains the following:
Most user guides and release notes are available in Adobe Acrobat Reader Portable Document Format (PDF) or HTML on the 3Com World Wide Web site:
Conventions Table 1 and Table 2 list conventions that are used throughout this guide.
Table 1 Notice Icons

Table 2 Text Conventions


Table 2 Text Conventions (continued)

In addition to this guide, each Switch documentation set includes the following:
This guide contains information on the features supported by your Switch and how they can be used to optimize your network. It is supplied in PDF format on the CD-ROM that accompanies the Switch.
This guide contains:
This guide provides detailed information about the web interface and command line interface that enable you to manage the Switch. It is supplied in HTML format on the CD-ROM that accompanies the Switch.
Related Documentation 9

These notes provide information about the current software release, including new features, modifications, and known problems. The Release Notes are supplied in hard copy with your Switch.
There are other publications you may find useful, such as:
To access the documentation on the CD-ROM supplied with your Switch, do the following:
1 Insert the CD-ROM into your CD-ROM drive. If your PC has auto-run enabled, a splash screen will be displayed automatically.
2 Select the Documentation section from the contents page.
If the online documentation is to be accessed from a local drive or server, you will need to access the CD-ROM contents via the root directory and copy the files from the CD-ROM to a suitable directory.
3Com recommends that you copy the Docs/reference directory as a whole to maintain the structure of the files.
Your suggestions are very important to us. They will help make our documentation more useful to you. Please e-mail comments about this document to 3Com at:

Please include the following information when commenting:
Example:
Part Number DUA1720-3AAA07 SuperStack 3 Switch 4400 Series Getting Started Guide
Please note that we can only respond to comments and questions about 3Com product documentation at this e-mail address. Questions related to technical support or sales should be directed in the first instance to your network supplier.
You can now register your SuperStack 3 Switch on the 3Com web site to receive up-to-date information on your product:
Product Registration 11 · Page 21


This chapter contains introductory information about the Switch 4400 and how it can be used in your network. It covers summaries of hardware and software features and also the following topics:

About the Switch 4400 The Switch 4400 is a stackable 10/100 Mbps Ethernet switch and provides high-performance workgroups with a backbone to server connection. The Switch 4400 allows Cascade, Gigabit Ethernet or Fast Ethernet Fiber connections when expansion modules are installed in the expansion slots on the rear of the unit. You can also add the Switch 4400 to any SuperStack® system as your network grows.
The Switch 4400 PWR (3C17205) supports Power over Ethernet on all front panel ports. If you plug in a compatible (IEEE 802.3af compliant) device, it will be automatically detected and power supplied to it. Power over Ethernet is enabled on each port by default.
The Switch 4400 FX (3C17210) has 24 100BASE-FX MT-RJ ports. These allow easy connection of 100 Mbps fiber-optic links.
Table 3 summarizes the hardware features that are supported by the Switch 4400.
Table 3 Hardware features

Duplex Modes Half and full duplex on all front panel ports
Flow Control In full duplex operation all ports are supported
Traffic Prioritization Supported (using the IEEE Std 802.ID, 1998 Edition): 4 queues per port
Power over Ethernet Supported on all front panel ports (3C17205 only).
RPS Support Connects to SuperStack 3 Advanced Redundant Power System (ARPS) (3C16071B)
Stacking All Switch units in the stack can be managed as a single entity with one IP address

Switch 4400 — Front View Detail 15
Figure 1 Switch 4400 FX — front view

Figure 2 Switch 4400 (24-port) / Switch 4400 SE — front view

11 12 3 4 6 5 7 8 9 10 1 2
on = enabled, link OK Yellow = 10Mbps Status Green = - 100Mbps Packet - Full Duplex Green =
13 14 15 16 17 18 19 20 21 22 23 24
Figure 3 Switch 4400 PWR — front view


Figure 4 Switch 4400 (48-port) — front view

Either shielded or unshielded data cables with shielded or unshielded jacks can be connected to these data sockets.
10BASE-T/ 100BASE-TX Ports The Switch 4400, 4400 SE and 4400 PWR have 24 or 48 auto-negotiating 10BASE-T/100BASE-TX ports configured as Auto MDIX (cross-over). These ports automatically provide the appropriate connection. Alternatively, you can manually set these ports to 10BASE-T half duplex, 10BASE-T full duplex, 100BASE-TX half duplex or 100BASE-TX full duplex. The maximum segment length is 100 m (328 ft) over Category 5 twisted pair cable.
The 4400 PWR will supply up to 15.4W of power through any of the 24 front panel ports in conformance to the 802.3af specification. The Switch 4400 PWR incorporates a LED Mode Button on the front panel, which when pressed changes the mode of the front panel port LEDs functionality between Switch and Power mode.
100BASE-FX Ports The Switch 4400 FX has 24 100BASE-FX MT-RJ ports. These are 100 Mbps fiber-optic ports that can use standard multi-mode fiber-optic cable of up to 2 kilometers (1.2 miles). They use the standard MT-RJ

Switch 4400 — Front View Detail 17
connector that allows both the transmit and the receive fibers to be connected in the same space as an RJ-45 port.
LEDs Table 4 lists LEDs visible on the front of the Switch, and how to read their status according to color. For information on using the LEDs for problem solving, see “Solving Problems Indicated by LEDs” on page 58.
Table 4 LED behavior
Green The Switch is powered-up and operating normally.
Green flashing The Switch is either downloading software or is initializing
(which includes running a Power On Self Test).
Yellow The Switch has failed its Power On Self Test
A port has failed and has been automatically disabled. You can verify this by checking that the Port Status LED is quickly flashing Yellow. If a port fails the Switch passes its Power On Self Test and continues to operate normally.
Off The Switch is not receiving power or there is a fault with the Power Supply Unit.
Packet Green Full duplex packets are being transmitted/received on the port.
Yellow Half duplex packets are being transmitted/received on the port.
Off No packets are being transmitted/received on the port.
Status Green A high speed (100 Mbps) link is present, and the port is enabled.
Green flashing A high speed (100 Mbps) link is present, but the port is
disabled.
Yellow A low speed (10 Mbps) link is present, and the port is enabled (not 4400 FX).
Yellow flashing A low speed (10 Mbps) link is present, but the port is
disabled (not 4400 FX).
The port has failed and has been automatically disabled. The Switch passes its Power On Self Test and continues to operate normally even if one or more ports are disabled.
Off No link is present.

Port LEDs — Power over Ethernet mode (3C17205 only)
Packet Green Power is being delivered to the port.
Green flashing Exceeded port power limit (overCurrent MIB state) or unable
to supply power due to unit over budget (denyLowPriority MIB state).
Yellow Power over Ethernet error, no power supplied on port.
Off No power is being delivered.
Status Yellow flashing Power over Ethernet POST error on port. Flash rate is 4 Hz
Packet Refer to the user documentation accompanying the module, if installed.
Status Refer to the user documentation accompanying the module, if installed.
Off There is no module installed in the expansion module slot.
The module has failed and has been automatically disabled. The Switch passes its Power On Self Test and continues to operate normally even if one or more modules are disabled.
1–8 Green When the Switch forms a stack with other Switch 4400 units, the LED indicates the position of the unit in the stack and that a link is present.
When the Switch is stand-alone and not part of a stack, LED 1 is on.
When a software upgrade is in progress, the LEDs of the unit that is being upgraded ‘rotate’ in an clockwise and anti-clockwise sequence.
The Switch physically forms a stack with other Switch 4400 units, but cannot be managed as part of that stack until all units have been upgraded to software version 2.0 or later.
Off A fault has occurred.
Port LED Status LED (3C17205 only)
Green Port LEDs are operating in power mode
Yellow flashing Port LEDs are operating in normal mode. One or more ports
has a Power over Ethernet error.
Off Port LEDs are operating in normal mode.
Power Utilization LEDs (3C17205 only)
Green 4 LEDs showing total power being delivered as a percentage of maximum possible.

Switch 4400 — Rear View Detail 19
Figure 5 Switch 4400 (all models) — rear view

Power Socket The Switch automatically adjusts its power setting to any supply voltage in the range 90-240 VAC.
To protect against internal power supply failure, you can use this socket to connect a Switch 4400 to a SuperStack 3 Advanced Redundant Power System (RPS). See “Connecting a Redundant Power System” on page 30.
Console Port The console port allows you to connect a terminal and perform remote or local out-of-band management. The console port uses a standard null modem cable and is set to auto-baud, 8 data bits, no parity and 1 stop bit.
You can use these slots to install Expansion Modules. These allow the Switch to support various forms of connection and add extra functionality to your Switch. For example you can install a Cascade module to enable the Switch to be stacked with other Switches. Please note that Power over Ethernet is not supported on expansion modules on the Switch 4400 PWR (3C17205). Contact your supplier for more information.

Default Settings Table 5 shows the default settings for the Switch 4400:
Table 5 Default Settings

Duplex Mode All fixed 10BASE-T and 100BASE-TX ports are auto-negotiated
100BASE-FX ports default to full-duplex mode (100 FD) and must be manually set to half-duplex mode (100 HD) if required.
Virtual LANs (VLANs) All ports belong to the untagged Default VLAN (VLAN 1) with IEEE Std 802.1Q-1998 learning operational
Traffic Prioritization All ports prioritize NBX VoIP traffic (LAN and IP). All ports set to “best effort” for all other traffic.

To make SSH, Webcache redirection, RADIUS (including 802.1x Network Login), Auto VLAN assignment, and Traffic Prioritization available on the SuperStack 3 Switch 4400 SE, upgrade the product to the Switch 4400 SE Enhanced Software Upgrade (3C17207).
If you initialize a Switch unit by selecting System > Control > Initialize in the Web interface or by entering system control initialize in the Command Line Interface, the following settings are retained to allow you to connect to and manage the Switch:
Default Settings 21


This chapter contains the information you need to install and set up the Switch 4400. It covers the following topics:

Package Contents ■ Switch unit
The Switch is suited for use on a desktop, either free standing or mounted in a standard 19-inch equipment rack. Alternatively, the Switch can be mounted in a wiring closet or equipment room, as an aggregator for other Hubs and Switches. A rack-mounting kit containing two mounting brackets is supplied with the Switch.
When deciding where to position the Switch, ensure that:
If the Switch is installed in a 19-inch rack or closed assembly its local air temperature may be greater than room ambient temperature.

Rack-mounting The Switch 4400 is 1U high and will fit in most standard 19-inch racks.
To rack-mount your Switch:
1 Place the Switch the right way up on a hard flat surface, with the front facing towards you.
2 Locate a mounting bracket over the mounting holes on one side of the Switch, as shown in Figure 6.
Rack-mounting 25

Figure 6 Fitting a bracket for rack-mounting

3 Insert the two screws and tighten with a suitable screwdriver.
You must use the screws supplied with the mounting brackets. Damage caused to the unit by using incorrect screws invalidates your warranty.
4 Repeat steps 2 and 3 for the other side of the Switch.
5 Insert the Switch into the 19-inch rack and secure with suitable screws (not provided). Ensure that ventilation holes are not obstructed.
6 Connect network cabling.
7 Finally place a unit information label on the unit in an easily accessible position. The unit information label shows the following:
You may need this information for fault reporting purposes.

Placing Units On Top of Each Other 27
If the Switch units are free-standing, up to eight units can be placed one on top of the other. If you are mixing a variety of SuperStack® 3 Switch and Hub units, the smaller units must be positioned at the top.
If you are placing Switch units one on top of the other, you must use the self-adhesive rubber pads supplied. Apply the pads to the underside of each Switch, sticking one in the marked area at each corner. Place the Switch units on top of each other, ensuring that the pads of the upper unit line up with the recesses of the lower unit.
Stacking Units Switch 4400 units can be stacked together and then treated as a single manageable unit with one IP address. Any combination of 24-port and 48-port units is allowed in a single stack.
The SuperStack 3 Switch 4400 SE can only be stacked with non-SE Switches if it has been upgraded using the Switch 4400 SE Enhanced Software Upgrade (3C17207). An upgraded Switch 4400 SE cannot be stacked with a normal Switch 4400 SE.
How To Stack Units To stack two Switch 4400 units you will need to order the SuperStack 3 Switch Cascade Stacking Kit (3C17227). The kit consists of two Cascade Modules and a Cascade Cable. Both Switches must have an unused expansion slot to allow a Cascade Module to be fitted.
Figure 7 Stacking two Switch 4400 units

To stack more than two Switch units you will need to order one SuperStack 3 Cascade Extender Kit (3C17228) for each additional unit. This Kit consists of one Cascade Module, one Cascade Cable and one

Cascade Extender Unit. The Cascade Module is installed into the expansion slot at the rear of the Switch and the Cascade Extender Unit plugs into the Cascade Module.
Figure 8 Stacking more than two Switch 4400 units

For information on ordering the Cascade Kits contact your supplier. For illustrations and information on how to install the Cascade Kits, refer to the user documentation that accompanies these Kits.
This information is also provided in the user documentation that accompanies the Cascade Kits.

Stacking Units 29

The following sections describe how to get your Switch 4400 powered-up and ready for operation.
Use the following sequence of steps to power-up the Switch.
1 Plug the power cord into the power socket at the rear of the Switch.
2 Plug the other end of the power cord into your power outlet.
The Switch powers-up and runs through its Power On Self Test (POST), which takes approximately 10 seconds.
During the Power On Self Test, all ports on the Switch are disabled and the LEDs light in a set sequence. When the POST has completed, check the Power/Self Test LED to make sure that your Switch is operating correctly. Table 6 shows possible colors for the LED.
Table 6 Power/Self Test LED colors

Yellow The Switch has failed its Power On Self Test.
If there is evidence of a problem, see “Solving Problems Indicated by LEDs” on page 58.
You can connect a SuperStack 3 Advanced Redundant Power System (3C16071B) to the Switch. This unit, which is also known as an RPS, is designed to maintain the power to your Switch if a power supply failure occurs.
For normal redundancy, the Switch 4400, Switch 4400 SE, and Switch 4400 FX require one Type 2A Power Module (3C16074A). For full redundancy, the Switch 4400, Switch 4400 SE, and Switch 4400 FX require two type 2A Power Modules combined using a Type 2 Y-Cable. The Switch 4400 PWR (3C17205) requires one Type 3 Power Module (3C16075) for normal redundancy and two Type 3 Power Modules for full redundancy.

The Power-up Sequence 31
The Switch 4400 PWR can power any IEEE 802.3af compliant device through any of its front panel ports. The Switch will support the following 3Com 802.3af equipment:

For the latest list of supported devices, go to the product page on the 3Com web site http://www.3com.com/.
For further information about Power Over Ethernet, refer to “Power Management and Control” in the Switch Implementation Guide supplied on the CD-ROM that accompanies your Switch. Power over Ethernet management is available using the web interface or the command line interface (CLI).
All of the ports on the front of the Switch 4400, 4400 SE and 4400 PWR are Auto-MDIX, that is they have a cross-over capability. The port can automatically detect whether it needs to operate in MDI or MDIX mode. Therefore you can make a connection to a port with a straight-through (MDI) or a cross-over cable (MDIX).
4400 SE and 4400 PWR)
The Auto-MDIX feature only operates when enabled per port and if auto-negotiation is enabled.
If auto-negotiation is disabled, all the Switch ports are configured as MDIX (cross-over). If you want to make a connection to another MDIX port, you need a cross-over cable. Many ports on workstations and servers are configured as MDI (straight-through). If you want to make a

The Power-up Sequence 33
connection to an MDI port, you need to use a standard straight-through cable. See Table 7.
3Com recommends that you use Category 5 twisted pair cable — the maximum segment length for this type of cable is 100 m (328 ft).
Table 7 Cables required to connect the Switch 4400 to other devices if

You can create a grounded port by connecting all wires at one end of a UTP cable to an earth ground point, and the other end to a female RJ-45 connector located, for example, on a Switch rack or patch panel. The RJ-45 connector is now a grounded port.
All of the ports on the front of the Switch 4400 FX are 100BASE-FX MT-RJ multi-mode ports. The MT-RJ port is a small form factor fiber-optic port with the transmit and receive fibers in the same cable. Unlike many fiber-optic systems, only one MT-RJ cable is needed to connect two MT-RJ ports together.
To connect a front-panel port to another 100BASE-FX MT-RJ multi-mode port, or to a patch panel, a single MT-RJ multi-mode pinless jumper cable is required. Since standard MT-RJ cables are cross-over cables, no
auto-negotiation is disabled

Auto-MDIX sensing is required. The maximum cable length is 2 kilometers (1.24 miles).
To connect a front-panel port to a 100BASE-FX single mode port, or to a port that does not have an MT-RJ connector, an adaptor will be required. It is not possible to connect a front panel port to a 1000BASE-FX port.

Your Switch can operate in its default state, that is, you can install it and it will work straight away (plug-and-play). However, to make full use of the features offered by the Switch, and to change and monitor the way it works, you have to access the management software that resides on the Switch. This is known as managing the Switch.
Managing the Switch can help you to improve the efficiency of the Switch and therefore the overall performance of your network.
This chapter explains the initial set up of the Switch and the different methods of accessing the management software to manage a Switch. It covers the following topics:

This section gives an overview of what you need to do to get your Switch set up and ready for management when it is in its default state. The whole setup process is summarized in Figure 9. Detailed procedural steps are contained in the sections that follow. In brief, you need to:
Figure 9 Initial Switch Setup and Management Flow diagram

Plug and Play Setup Initial IP Information Setup Feature Management
Do you want to manually configure the IP information?
configured IP information? How do you want to connect to the Switch?
Connect to a front panel port and use the
How do you want to manage your Switch? See page 49

Setting Up Overview 37
IP Configuration You can use one of the following methods to allocate IP information to your Switch (essential if you wish to manage your Switch across the network).
You can choose to configure the IP information yourself. The Switch remembers the information that you enter until you change it again or set the configuration method to Automatic.
You should use the Manual IP configuration method if:
For most installations, 3Com recommends that you configure the Switch IP information manually. This makes management simpler and more reliable as it is not dependent on a DHCP or BootP server, and eliminates the risk of the IP address changing.
If you wish to manually enter IP information for your Switch, work through the “Manually Configuring IP Information” section on page 39.
By default the Switch tries to configure itself with IP information without requesting user intervention. It tries to obtain an IP address from a DHCP or BootP server on the network.
If neither server is found, the Switch will configure itself with its default IP address 169.254.100.100 if it is operating in a standalone mode, and/or no other Switches on the network have this IP address. If this default IP address is already in use on the network then the Switch detects this and configures itself with an IP address in the range 169.254.1.0 to 169.254.254.255.

This process is known as Auto-IP and is the same mechanism used by Windows 98 and Windows 2000. IP addresses configured by Auto-IP are temporary as they cannot be routed but are useful for small networks which are not connected to other networks, or for initial configuration.
However, as soon as a DHCP or BootP server is detected, the Switch will configure itself with the IP address allocated by that server.
When using automatic IP configuration it is important that the IP address of the Switch is static, otherwise you will not know what the IP address is and it will be difficult to manage. Most DHCP and BootP servers allow static IP addresses to be configured so that you know what IP address will be allocated to the Switch. Refer to the documentation that accompanies your DHCP/BootP server.
For a detailed description of how automatic IP configuration operates, please refer to the Implementation Guide on the CD-ROM that accompanies your Switch or on the 3Com Web site.
You should use the automatic IP configuration method if:
If you use the automatic IP configuration method, you need to discover the automatically allocated IP information before you can begin management. Work through the “Viewing Automatically Configured IP Information” section on page 46.
Once your Switch’s initial set up is complete you can set up your chosen management method as described in “Methods of Managing a Switch” on page 49.
For detailed information about the specific web interface operations and command line interface commands and problem solving, refer to the “SuperStack 3 Switch Management Interface Reference Guide” on the CD-ROM that is supplied with the Switch or on the 3Com Web site.

Manually Configuring IP Information 39
You can manually configure the Switch IP information in the following ways:
To set up your Switch manually you can make a connection to a front panel port. You must do this whilst the Switch is offline, that is, before you connect the Switch to a network.
The procedure described in this section assumes the unit has been powered up in standalone mode and has the default IP address of 169.254.100.100.

1 Connect the workstation to a front panel port using an Ethernet cable as shown in Figure 10.
Figure 10 Connecting a workstation to the Switch via a front panel port

To connect the cable:
a Attach an RJ-45 connector at one end of the Ethernet cable to the Network Interface Card (NIC) in the workstation.
b Connect the RJ-45 connector at the other end of the cable to one of
the front panel ports on the Switch.
Do not interconnect the Switch to any other unconfigured Switch.
You need to change the IP address and subnet mask of the workstation that you have connected to the Switch. Make a note of the existing settings so you can return to them later. Change the workstation to the following settings:
You are now ready to manually set up the Switch with IP information. You can do this using the Web interface or the command line interface (CLI) via telnet.
1 Power-up the Switch. This takes approximately one minute.
2 Open a suitable Web browser and enter 169.254.100.100 in the Location Address field. This is the default IP address that is automatically assigned to an offline unit.

Manually Configuring IP Information 41
If there is no response, wait for one minute then re-enter the default IP address.
3 At the login and password prompts, enter admin as your user name and press Return at the password prompt (default user name and password). If you have logged on correctly, a set of Getting Started pages are displayed.
4 The Getting Started pages allow you to enter basic setup information for the Switch. Select Manual and then enter the IP address, subnet mask, and default gateway that you want the Switch to use when it is connected to the network. The final page displays a summary of the information entered.
The initial set up of your Switch is now complete and the Switch is ready for you to set up your chosen management method. See “Methods of Managing a Switch” on page 49.
1 To start a Telnet session to the unit, click Start in Microsoft Windows 95/98/2000/NT/XP.
a Click Run.
b In the dialogue box that appears type the default IP address of the
c Click OK.
2 Press Enter to open a login prompt.
If the login prompt does not begin immediately, press Return a few times until it starts.
3 At the login and password prompts, enter admin as your user name and press Return at the password prompt. If you have logged on correctly, the top-level menu of the command line interface is displayed as shown in the example in Figure 11.

Figure 11 Example top-level command line interface menu

4 At the Select menu option prompt you can either:
5 Enter the IP address, subnet mask, and gateway IP address for the Switch. The screen displays a summary of the information entered.
If using the gettingStarted command you will then be prompted to enter system information, change passwords, and then given the option to carry out advanced configuration.
The protocol ip basicConfig command will prompt you for the management VLAN ID. If the unit is new there is only one VLAN (VLAN 1) to choose from.
The initial set up of your Switch is now complete and the Switch is ready for you to set up your chosen management method. See “Methods of Managing a Switch” on page 49.
To set up your Switch manually you can alternatively make a connection to the console port (this example describes a local connection to the console port, rather than a remote one via a modem). You can do this whilst the Switch is offline, that is, before you connect the Switch to a network, or whilst the Switch is online, that is, connected to a network.
or

Manually Configuring IP Information 43
You can find pin-out diagrams for both cables in Appendix B on page 73.
1 Connect the workstation to the console port using a standard null modem cable as shown in Figure 12.
Figure 12 Connecting a workstation to the Switch via the console port

To connect the cable:
a Attach the female connector on the cable to the male connector on the console port of the Switch. b Tighten the retaining screws on the cable to prevent it from being
loosened. c Connect the other end of the cable to one of the serial ports (also known as a COM port) on your workstation.

2 Open your terminal emulation software and configure the COM port settings to which you have connected the cable. The settings should be set to match the default settings for the Switch, which are:
Refer to the documentation that accompanies the terminal emulation software for more information.
You are now ready to manually set up the Switch with IP information using the command line interface.
1 The command line interface login sequence begins as soon as the Switch detects a connection to its console port.
If the login prompt does not begin immediately, press Return a few times until it starts.
2 At the login and password prompts, enter admin as your user name and press Return at the password prompt. If you have logged on correctly, the top-level menu of the command line interface is displayed as shown in the example in Figure 13.

Manually Configuring IP Information 45
Figure 13 Example top-level command line interface menu

3 At the Select menu option prompt you can either:
4 Enter the IP address, subnet mask, and gateway IP address for the Switch. The screen displays a summary of the information entered.
If using the gettingStarted command you will then be prompted to enter system information, change passwords, and then given the option to carry out advanced configuration.
The protocol ip basicConfig command will prompt you for the management VLAN ID. If the unit is new there is only one VLAN (VLAN 1) to choose from.
The initial set up of your Switch is now complete and the Switch is ready for you to set up your chosen management method. See “Methods of Managing a Switch” on page 49.
If you do not intend to use the command line interface via the console port to manage the Switch, you can disconnect the serial cable and close the terminal emulator software.
or

If you allow the Switch to automatically configure its own IP information you need to discover and view the IP information before you can begin to manage the Switch. You can discover the IP information in two ways:
You can use the 3Com Network Supervisor application provided on the CD-ROM that accompanies your Switch to discover the automatically allocated IP information.
1 Connect your Switch to the network.
2 Power-up the Switch and wait for two minutes.
3 Launch 3Com Network Supervisor and run the Auto-discovery wizard.
3Com Network Supervisor will auto-discover the new Switch and display the IP information that has been automatically allocated to the Switch.
Most DHCP and BootP servers allow static IP addresses to be configured so that you know what IP address the Switch will be given. Refer to the documentation that accompanies your DHCP or BootP server.
If your network does not have a DHCP or BootP server, the workstation running 3Com Network Supervisor must be on the same subnet as the Switch, because Auto-IP addresses are non-routable.
Alternatively, you can view the automatically configured IP information via the command line interface (CLI) through a connection to the console port. (This example describes a local connection to the console port, rather than a remote one via a modem.)
Pre-requisites

Viewing Automatically Configured IP Information 47
You can find pin-out diagrams for both cables in Appendix B on page 73.
1 Connect the workstation to the console port using a standard null modem cable as shown in Figure 14.
Figure 14 Connecting a workstation to the Switch via the console port

To connect the cable:
a Attach the female connector on the cable to the male connector on the console port of the Switch. b Tighten the retaining screws on the cable to prevent it from being
loosened. c Connect the other end of the cable to one of the serial ports (also known as a COM port) on your workstation.
2 Open your terminal emulation software and configure the COM port settings to which you have connected the cable. The settings should be set to match the default settings for the Switch, which are:
Refer to the documentation that accompanies the terminal emulation software for more information.

You are now ready to view the automatically allocated IP information using the command line interface.
1 Connect your Switch to the network using an Ethernet cable. As soon as a network connection is made the Switch begins the automatic IP configuration process.
The automatic IP configuration process usually completes within one minute.
If there is no response from a DHCP server within 30 seconds, the Auto-IP configuration mechanism attempts to allocate the default IP address 169.254.100.100. If this address is not available, it then allocates an IP address in the range of 169.254.x.y (where x is in the range 1 to 254, and y is in the range 0 to 255).
2 The command line interface login sequence begins as soon as the Switch detects a connection to its console port.
If the login prompt does not begin immediately, press Return a few times until it starts.
3 At the login and password prompts, enter admin as your user name and press Return at the password prompt. If you have logged on correctly, the top-level menu of the command line interface is displayed as shown in the example in Figure 15.
Figure 15 Example top-level command line interface menu

4 At the Select menu option prompt enter the protocol ip interface summary command. At the Select IP interfaces prompt enter all. A summary of the automatically allocated IP information is displayed. Make a note of the Network IP Address.

Methods of Managing a Switch 49
The initial set up of your Switch is now complete and the Switch is ready for you to set up your chosen management method. See “Methods of Managing a Switch” on page 49.
If you do not intend to use the command line interface via the console port to manage the Switch, you can logout, disconnect the serial cable and close the terminal emulator software.
Once you have completed the initial set up of your Switch, you can decide how you wish to manage the Switch. You can use one of the following methods:
Each Switch has a command line interface (CLI) that allows you to manage the Switch from a workstation, either locally via a console port connection (see Figure 16), or remotely over the network (see Figure 17).
Figure 16 CLI management via the console port

Figure 17 CLI management over the network

Refer to “Setting Up Command Line Interface Management” on page 50.

The Switch 4400 supports Secure Shell version 2 (SSHv2), allowing secure access to the Command Line Interface of the Switch.
If you use SSH to administer your Switch and the network traffic is intercepted, no passwords or configuration information will be visible in the data. To securely adminster the Switch using the Command Line Interface you need a third party SSH client.
Web Interface
Each Switch has an internal set of web pages that allow you to manage the Switch using a Web browser remotely over an IP network (see Figure 18).
Figure 18 Web interface management over the network
Refer to “Setting Up Web Interface Management” on page 53.
SNMP Management You can manage a Switch using any network management workstation running the Simple Network Management Protocol (SNMP) as shown in Figure 19. For example, you can use the 3Com Network Supervisor software that is provided on the CD-ROM that accompanies your Switch.
Figure 19 SNMP management over the network

Refer to “Setting Up SNMP Management” on page 54.
This section describes how you can set up command line interface management using a local console port connection or over the network.

Setting Up Command Line Interface Management 51
To manage a Switch using the command line interface via the local console port connection:
1 Ensure you have connected your workstation to the console port correctly as described in “Connecting to the Console Port” on page 42.
2 Your Switch is now ready to continue being managed and/or configured through the CLI via its console port.
To manage a Switch using the command line interface over a network using Telnet:
1 Ensure you have already set up the Switch with IP information as described in “Setting Up Overview” on page 36.
2 Check that you have the IP protocol correctly installed on your management workstation. You can check this by trying to browse the World Wide Web. If you can browse, the IP protocol is installed.
3 Check you can communicate with the Switch by entering a ping command at the DOS prompt in the following format:
c:\ ping xxx.xxx.xxx.xxx (where xxx.xxx.xxx.xxx is the IP address of the Switch)
If you get an error message, check that your IP information has been entered correctly and the Switch is powered up.
4 To open a Telnet session via the DOS prompt, enter the IP address of the Switch that you wish to manage in the following format:
>telnet xxx.xxx.xxx.xxx (where xxx.xxx.xxx.xxx is the IP address of the Switch)
If opening a Telnet session via third party software you will need to enter the IP address in the format suitable for that software.
5 At the login and password prompts, enter admin as your user name and press Return at the password prompt (or the password of your choice if you have already modified the default passwords).
If the login prompt does not display immediately, press Return a few times until it starts.
6 If you have logged on correctly, the top-level menu of the command line interface for the Switch you wish to manage is displayed as shown in Figure 13 on page 45.

This section describes how you can set up Command Line Interface management using SSH over a network.
To manage a Switch using the command line interface over a network using SSH:
1 Ensure you have already set up the Switch with IP information as described in “Setting Up Overview” on page 36.
2 Check that you have the IP protocol correctly installed on your management workstation. You can check this by trying to browse the World Wide Web. If you can browse, the IP protocol is installed.
3 Check you can communicate with the Switch by entering a ping command at the DOS prompt in the following format:
c:\ ping xxx.xxx.xxx.xxx (where xxx.xxx.xxx.xxx is the IP address of the Switch)
If you get an error message, check that your IP information has been entered correctly and the Switch is powered up.
The switch automatically generates a host key pair when it is powered up for the first time, or after any reset to factory defaults. Host key generation may take a while, during which time SSH connections to the switch will be refused.
4 Install an SSH client application on the workstation you want to use to access the switch.
3Com recommends the following SSH clients; PuTTY, OpenSSH and SSH Communications Security Corp Secure Shell.
5 Open an SSH session and access the switch using the switch’s IP address and port number.
The first time you connect to the switch the client will ask you to confirm that the host key is correct for the device.
6 The switch and the SSH client will authenticate each other and a secure connection will be established.
7 Enter your usual username and password to access the CLI commands.
For increased security please change the default password when using SSH for the first time.

Setting Up Web Interface Management 53
For further information on generating a host key on your switch and transferring keys to the Switch using TFTP server please refer to Chapter 11 of the “SuperStack 3 Switch Implementation Guide”.
This section describes how you can set up web interface management over the network.
Pre-requisites ■ Ensure you have already set up the Switch with IP information as described in “Setting Up Overview” on page 36.
To display the web interface correctly, use one of the following Web browser and platform combinations:
Table 8 Supported Web Browsers and Platforms

Internet Explorer 6.0 ✕ ✓ ✓ ✓ ✓ ✕
For the browser to operate the web interface correctly, JavaScript™ and Cascading Style Sheets must be enabled on your browser. These features are enabled on a browser by default. You will only need to enable them if you have changed your browser settings.
To enable style sheets in Netscape Navigator 4.76 on Solaris 2.6, open Netscape Navigator and select Edit > Preferences > Fonts. Select the Use document-specified fonts, including Dynamic Fonts radio button. You should also set the font sizes as follows:

This ensures that the text spacing is correct. Finally in the Advanced category ensure that Enable Java Script and Enable style sheets are checked.
To manage a Switch using the web interface over an IP network:
1 Check that you have the IP protocol correctly installed on your management workstation. You can check this by trying to browse the World Wide Web. If you can browse, the IP protocol is installed.
2 Check you can communicate with the Switch by entering a ping command at the DOS prompt in the following format:
c:\ ping xxx.xxx.xxx.xxx (where xxx.xxx.xxx.xxx is the IP address of the Switch)
If you get an error message, check that your IP information has been entered correctly and the Switch is powered up.
3 Open your web browser and enter the IP address of the Switch that you wish to manage in the URL locator, for example, in the following format:
4 At the login and password prompts, enter admin as your user name and press Return at the password prompt (or the password of your choice if you have already modified the default passwords).
5 Click on the Device View button to display the web management options.
Any network management application running the Simple Network Management Protocol (SNMP) can manage a Switch if:
You can use the 3Com Network Supervisor application that is provided on the CD-ROM that accompanies your Switch to provide SNMP management for your Switch. If you use 3Com Network Supervisor it

Default Users and Passwords 55
automatically loads the correct MIBs and necessary files onto your workstation.
Pre-requisites ■ Documentation supplied with the SNMP network management application software.
To manage your Switch using an SNMP network management application, you need to specify SNMP community strings for the users defined on the Switch. You can do this using the command line interface system management snmp community command — refer to the command line interface section of the “SuperStack 3 Switch Management Interface Reference Guide” for more information.
If you intend to manage the Switch using the web interface or the command line interface, or to change the default passwords, you need to log in with a valid user name and password. The Switch has three default user names, and each user name has a different password and level of access. These default users are listed in Table 9.
Table 9 Default Users

monitor monitor monitor — the user can view all manageable parameters, except special/security features, but cannot change any manageable parameters
manager manager manager — the user can access and change the operational parameters but not special/security features
security — the user can access and change all manageable parameters
Use the admin default user name (no password) to login and carry out initial Switch setup.
You can change the default passwords using either:

For more information about default users and passwords, refer to the “Superstack 3 Switch Management Interface Reference Guide” on the Switch CD-ROM.

This chapter helps you to diagnose and solve problems you may have with the operation of your Switch. There is also an explanation of IP addressing.
The topics covered are:
If you experience a problem that is not listed here, it may be included in the Support section of the Superstack 3 Switch Management Interface Reference Guide on the CD-ROM that accompanies your Switch.
For Technical Support information, see Appendix D.

Solving Problems Indicated by LEDs
If the LEDs on the Switch indicate a problem, refer to the list of suggested solutions below.
Check that the power cable is firmly connected to the Switch and to the supply outlet. If the connection is secure and there is still no power, you may have a faulty power cord or an internal fault. Firstly, check the power cord by:
then contact your supplier for advice.
Either:
The port has failed and has been automatically disabled. The Switch passes its Power On Self Test and continues to operate normally, even if one or more ports are disabled.
A link is connected and yet the Status LED for the port does not light
Check that:
or

Solving Hardware Problems 59
Auto-negotiation problems will occur with 10BASE-T or 100BASE-T where auto-negotiation is disabled and incorrect cables are being used (cross-over or straight)
Auto-negotiation problems will occur with fiber if:
The Switch unit physically forms a stack with other Switch 4400 units, but cannot be managed as part of that stack because one or more units have not been upgraded to software version 2.0 or later. You must upgrade each unit in the stack to this software version, which is available on the CD-ROM that accompanies your Switch.
The Switch has a Power over Ethernet error. You must press the LED Mode button to see which ports are affected and to see whether it is a fault or a power budget issue. If there is a fault, then the Packet LED of the affected port will be yellow. If a port exceeds its power limit, then the Packet LED of the port will flash green. If a port has a Power over Ethernet POST error then the Status LED of the affected port will flash yellow.
In the rare event of your Switch unit experiencing a hardware failure, refer to the list of suggested solutions below.
Ensure that the expansion module is fully seated in the slot and the connectors are engaged so that the securing screws can be tightened.
Your Switch has a fan monitoring system that will generate fan failure warning messages. Fan failure could potentially reduce the lifetime of the

Switch. The monitoring system polls the fan status at periodic intervals while the unit is powered up.
If one fan has failed in the Switch, a warning message will be generated in the following ways:
For further information about RMON, refer to “Chapter 7: Status Monitoring and Statistics” in the Switch Implementation Guide supplied in PDF format on the CD-ROM that accompanies the Switch.
If more than one fan has failed in the Switch, a warning message will be generated by RMON Email Notification, RMON Trap and also in the following ways:
If a fan failure warning message is generated:
1 Power off the unit.
2 Check that the air vents are not obstructed.
3 Power cycle the unit. To do this, remove and reconnect the AC mains supply. If the unit has no AC main supply, remove and reconnect the DC RPS supply.
4 If another fan failure warning message is generated via the Command Line Interface or the Web interface, return the unit.

Solving Hardware Problems 61
1 Power cycle the unit. To do this, remove and reconnect the AC mains supply. If the unit has no AC mains supply, remove and reconnect the DC RPS supply.
2 Check the command line interface (system summary command) to determine whether a thermal shutdown has occurred.
3 If no, return the unit:
If yes, check that:
4 Power cycle the unit. If a further thermal shutdown occurs, and all environmental conditions are satisfactory, return the unit to 3Com.
A device is connected to a Switch 4400 PWR but power is not being supplied
If power is not being supplied to a device connected to a Switch 4400 PWR, you should do the following checks:
The 4400 PWR will only supply power through the front panel ports to 802.3af compliant devices.
If the power budget has been exceeded, then by default, the powered device connected to the Power over Ethernet port with the lowest priority port will lose power. However, if all the devices connected to the Switch have equal priority levels, then the port with the highest number will lose power.
By default the Switch will allow a device to receive power as long as the Power over Ethernet power supply has 18 watts spare in its power budget. If this much power is not available the device will not be powered (unless it has a higher priority than existing powered ports) and a Power over Ethernet fault will be reported for that port. If enough power subsequently becomes available the port will be powered.

Solving Communication Problems
If you experience communication problems with the Switch, ensure that:
The following is a brief overview of IP addressing, and how to obtain a registered IP address.
To be managed correctly, each device on your network (for example a Switch or Hub) must have a unique IP address. IP addresses have the format n.n.n.n where n is a decimal number between 0 and 255. An example IP address is 192.168.100.8.
The IP address is split into two parts:
The natural subnet mask for this example is 255.255.255.0.
If your network has a connection to the external IP network, that is, you access the Internet, you must apply for a registered IP address.
The IP registration system ensures that every IP address used is unique; if you do not have a registered IP address, you may be using an identical address to someone else and your network will not operate correctly.
InterNIC Registration Services is the organization responsible for supplying registered IP addresses. The following contact information is correct at time of publication:

Solving Software Upgrade Problems 63
If your IP network is internal to your organization only, that is, you do not access the Internet, you may use any arbitrary IP address as long as it is not being used by another device on your network. 3Com suggests you use addresses in the range 192.168.0.0 to 192.168.255.255 with a subnet mask of 255.255.255.0.
These suggested IP addresses are part of a group of IP addresses that have been set aside specially for use ‘in house’ only.
You can upgrade the management software of the Switch by using the System > Control > Software Upgrade operation in the Web Interface, or the system control softwareUpgrade command in the command line interface. For details on these options, refer to the Management Interface Reference Guide supplied in HTML format on the CD-ROM that accompanies your Switch.
If you have problems with your software upgrade, refer to the Problem Solving section in the Management Interface Reference Guide.


You must read the following safety information before carrying out any installation or removal of components, or any maintenance procedures on the Switch 4400.


Important Safety Information
U.S.A. and Canada
Europe only: ■ The supply plug must comply with CEE 7/7 (“SCHUKO”).
Denmark ■ The supply plug must comply with section 107-2-D1, standard DK2-1a or DK2-5a.
Switzerland ■ The supply plug must comply with SEV/ASE 1011.
United Kingdom only

Either shielded or unshielded data cables with shielded or unshielded jacks can be connected to these data sockets.
Never look at the transmit LED through a magnifying device while it is powered on. Never look directly at the fiber TX port and fiber cable ends when they are powered on.

Modem Cable 9-pin to RS-232 25-pin

Pin assignments are identical for 10BASE-TX and 100BASE-T RJ-45 connectors.
Table 10 Pin assignments


RJ-45 Pin Assignments 75
Table 11 Pin assignments




Physical Dimensions Height: 44 mm (1.7 in.) x Width: 440 mm (17.3 in.) x Depth: 274 mm (10.8 in.) Weight: 2.8 kg (6.2 lbs)
Operating Temperature 0 ° to 40 °C (32 ° to 104 °F)
Storage Temperature –40 ° to +70 °C (-40 ° to 158 °F)
Standards EN60068 to 3Com schedule (Package testing: paras 2.1, 2.2, 2.30, and 2.32. Operational testing: paras 2.1, 2.2, 2.30 and 2.13).
Agency Certifications UL 1950, EN60950, CSA 22.2 No. 950, IEC 60950
Emissions CISPRR 22 Class A, EN55022 Class A, FCC Part 15 Subpart B Class A,
ICES-003 Class A, AS/NZS 3548 Class A, EN61000-3-2, EN61000-3-3


* Supported on a Switch 4400 and an upgraded Switch 4400 SE.

Switch 4400 PWR (24-port) 79

Physical Dimensions Height: 44 mm (1.7 in.) x Width: 440 mm (17.3 in.) x Depth: 295 mm (11.4 in.) Weight: 4.4 kg (9.7 lbs)
Operating Temperature 0 ° to 40 °C (32 ° to 104 °F)
Storage Temperature –20 ° to +70 °C (-4 ° to 158 °F)
Standards EN60068 to 3Com schedule (Package testing: paras 2.1, 2.2, 2.30, and 2.32. Operational testing: paras 2.1, 2.2, 2.30 and 2.13).
Agency Certifications UL60950, EN60950, CSA 22.2 No. 60950, IEC 60950
Emissions CISPRR 22 Class A, EN55022 Class A, FCC Part 15 Subpart B Class A,
ICES-003 Class A, AS/NZS 3548 Class A, EN61000-3-2, EN61000-3-3

Switch 4400 (48-port)

Physical Dimensions Height: 44 mm (1.7 in.) x Width: 440 mm (17.3 in.) x Depth: 274 mm (10.8 in.) Weight: 3.2 kg (7.1 lbs)
Operating Temperature 0 ° to 40 °C (32 ° to 104 °F)
Storage Temperature –40 ° to +70 °C (-40 ° to 158 °F)
Standards EN60068 to 3Com schedule (Package testing: paras 2.1, 2.2, 2.30, and 2.32. Operational testing: paras 2.1, 2.2, 2.30 and 2.13).
Agency Certifications UL60950, EN60950, CSA 22.2 No. 60950, IEC 60950
Emissions CISPR 22 Class A, EN55022 Class A, FCC Part 15 Subpart B Class A,
ICES-003 Class A, AS/NZS 3548 Class A, VCCI Class A,

Switch 4400 FX 81


Physical Dimensions Height: 44 mm (1.7 in.) x Width: 440 mm (17.3 in.) x Depth: 274 mm (10.8 in.) Weight: 2.8 kg (6.2 lbs)
Operating Temperature 0 ° to 40 °C (32 ° to 104 °F)
Storage Temperature –40 ° to +70 °C (-40 ° to 158 °F)
Standards EN60068 to 3Com schedule (Package testing: paras 2.1, 2.2, 2.30, and 2.32. Operational testing: paras 2.1, 2.2, 2.30 and 2.13).
Agency Certifications UL60950, EN60950, CSA 22.2 No. 60950, IEC 60950
Emissions CISPRR 22 Class A, EN55022 Class A, FCC Part 15 Subpart B Class A,
ICES-003 Class A, AS/NZS 3548 Class A, EN61000-3-2, EN61000-3-3



To take advantage of warranty and other service benefits, you must first register your product at http://eSupport.3com.com/. 3Com eSupport services are based on accounts that you create or have authorization to access. First time users must apply for a user name and password that provides access to a number of eSupport features including Product Registration, Repair Services, and Service Request.
To enhance response times or extend warranty benefits, contact 3Com or your authorized 3Com reseller. Value-added services can include 24x7 telephone technical support, software upgrades, onsite assistance or advance hardware replacement. Experienced engineers are available to manage your installation with minimal disruption to your network. Expert assessment and implementation services are offered to fill resource gaps and ensure the success of your networking projects. More information on 3Com Extended Warranty and Professional Services is available at http://www.3com.com/
Contact your authorized 3Com reseller or 3Com for additional product and support information.
You will find support tools posted on the 3Com web site at http://www.3com.com/

Software Updates are the bug fix / maintenance releases for the version of software initially purchased with the product. In order to access these Software Updates you must first register your product on the 3Com web site at http://eSupport.3com.com/.
First time users will need to apply for a user name and password. A link to software downloads can be found at http://eSupport.3com.com/, or under the Product Support heading at http://www.3com.com/
Software Upgrades are the software releases that follow the software version included with your original product. In order to access upgrades and related documentation you must first purchase a service contract from 3Com or your reseller.
Contact Us 3Com offers telephone, e-mail and internet access to technical support and repair services. To access these services for your region, use the appropriate telephone number, URL or e-mail address from the list below. You will find a current directory of support telephone numbers posted on the 3Com web site at http://csoweb4.3com.com/contactus/
To obtain telephone support as part of your warranty and other service benefits, you must first register your product at http://eSupport.3com.com/
When you contact 3Com for assistance, please have the following information ready:

Telephone Technical Support and Repair 85
To send a product directly to 3Com for repair, you must first obtain a return authorization number (RMA). Products sent to 3Com, without authorization numbers clearly marked on the outside of the package, will be returned to the sender unopened, at the sender’s expense. If your product is registered and under warranty, you can obtain an RMA number online at http://eSupport.3com.com/. First time users will need to apply for a user name and password.
Telephone numbers are correct at the time of publication. Find a current directory of support telephone numbers posted on the 3Com web site at http://csoweb4.3com.com/contactus/
Country Telephone Number Country Telephone Number
Asia, Pacific Rim Telephone Technical Support and Repair
Australia Hong Kong India
1 800 678 515 800 933 486 +61 2 9424 5179 or 000800 650 1111 001 803 61009 00531 616 439 or 03 5977 7991 1800 801 777 0800 446 398 +61 2 9937 5083
1235 61 266 2602 or 1800 1 888 9469 10800 61 00137 or 021 6350 1590 or 00800 0638 3266 800 6161 463 080 333 3308 00801 611 261 001 800 611 2000
P.R. of China
Singapore S. Korea Taiwan Thailand
Malaysia New Zealand Pakistan
You can also obtain support in this region using the following e-mail: apr_technical_support@3com.com
Or request a repair authorization number (RMA) by fax using this number: + 65 543 6348
Europe, Middle East, and Africa Telephone Technical Support and Repair
From anywhere in these regions, call:
From the following countries, you may use the numbers shown:
Austria Belgium Denmark Finland France Germany Hungary Ireland Israel Italy
01 7956 7124 070 700 770 7010 7289 01080 2783 0825 809 622 01805 404 747 06800 12813 01407 3387 1800 945 3794 199 161346
Luxembourg Netherlands Norway Poland Portugal South Africa Spain Sweden Switzerland U.K.
342 0808128 0900 777 7737 815 33 047 00800 441 1357 707 200 123 0800 995 014 9 021 60455 07711 14453 08488 50112 0870 909 3266
You can also obtain support in this region using the following URL: http://emea.3com.com/support/email.html
Philippines · Indonesia Japan · +44 (0)1442 435529

Country Telephone Number Country Telephone Number
Latin America Telephone Technical Support and Repair
Antigua Argentina Aruba Bahamas Barbados Belize Bermuda Bonaire Brazil Cayman Chile Colombia Costa Rica Curacao Ecuador Dominican Republic
1 800 988 2112 0 810 444 3COM 1 800 998 2112 1 800 998 2112 1 800 998 2112 52 5 201 0010 1 800 998 2112 1 800 998 2112 0800 13 3COM 1 800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 1 800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112
Guatemala Haiti Honduras Jamaica Martinique Mexico Nicaragua Panama Paraguay Peru Puerto Rico Salvador Trinidad and Tobago Uruguay Venezuela Virgin Islands
AT&T +800 998 2112 57 1 657 0888 AT&T +800 998 2112 1 800 998 2112 571 657 0888 01 800 849CARE AT&T +800 998 2112 AT&T +800 998 2112 54 11 4894 1888 AT&T +800 998 2112 1 800 998 2112 AT&T +800 998 2112 1 800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 57 1 657 0888
You can also obtain support in this region using the following:
English speakers in Latin America should send e-mail to: lat_support_anc@3com.com
US and Canada Telephone Technical Support and Repair
1 800 876 3266


FCC STATEMENT This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference to radio communications, in which case the user will be required to correct the interference at their own expense.
INFORMATION TO THE USER If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user may find the following booklet prepared by the Federal Communications Commission helpful:
How to Identify and Resolve Radio-TV Interference Problems
This booklet is available from the U.S. Government Printing Office, Washington, DC 20402, Stock No. 004-000-00345-4.
In order to meet FCC emissions limits, this equipment must be used only with cables which comply with IEEE 802.3.
CSA STATEMENT This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
CE STATEMENT (EUROPE) This product complies with the European Low Voltage Directive 73/23/EEC and EMC Directive 89/336/EEC as amended by European Directive 93/68/EEC.



Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.