ADJUST ABLE SPEED DRIVE Series 5 Inverter NEMA 4X, IP-65 8/01 MN781B Installation & Operating Manual.
T ABLE OF CONTENTS Section Page i. Simplified Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 ii. Safety W arning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
i . SIMPLIFIED OPERA TING INSTRUCTIONS W ARNING! Disconnect main power when making connections to the control. A . AC Line Connection – Connect the AC line to L1 and L2 terminals of T erminal Block .
I. INTRODUCTION The Baldor ID5601-BO Adjustable Speed Drive is a variable speed control in a NEMA-4X / IP- 65 and watertight enclosure. It is designed to operate 208 - 230 V olt 3-phase AC induction motors through 3.
3 VIOLET WHITE ORANGE (BACK VIEW) MAIN SPEED POTENTIOMETER (BACK VIEW) START/STOP SWITCH 1. 2. FOR OPTIONAL ID5SI-2 SIGNAL ISOLATOR. ARE USED FOR OPTIONAL R/F, B- AND B+ TERMINALS FWD-STOP-REV SWITCH.
4 POWER ST A TUS REVERSE FORW ARD STOP ST ART POWER 50 40 0 60 70 80 90 100 ON OFF 30 20 10 AUT O MANUAL STOP % SPEED SHOWN WITH OPTIONAL AUTO/MANUAL AND FORWARD-STOP-REVERSE RECOMMENDED MOUNTING SCREW: 1/4" (M6) 2.53 [139.97] 5.51 [128.59] 5.06 [7.
5 II. WIRING INSTRUCTIONS W ARNING! Read Safety Warning, on page 1, before using this control. Disconnect the AC line before wiring. Note: T o avoid erratic operation, do not bundle AC line and motor wires with wires from sig- nal following, Start/Stop Switch or any other signal wires.
A. AC Line Connection – Wire the AC line input to L1 and L2 terminals of T erminal Block TB1 as shown in Figure 4. Be sure both Jumpers J1 and J2 are set to the “1 15V” posi- tion for 1 15 V olt AC line input or to the “230V” position for 208/230 V olt AC line input.
Note: T o eliminate the Start/Stop function, connect RUN and COM terminals with the jumper that is provided. See Figure 7, on page 6. CAUTION! Using a jumper to eliminate the Start/Stop function will cause the motor to run at the Main Speed Potentiometer setting when the AC line is applied.
8 fault). T o set the control to automatically reset after a fault has been cleared, set Jumper J3 to the "AUTO" position. See Figure 12. (Also see section VIB, on page 9 and T able 4, on page 10.
9 B. The hi-pot tester must have an automatic ramp-up to the test voltage and an automatic ramp-down to zero voltage. Note: If the hi-pot tester does not have automatic ramping, then the hi-pot output must be manually increased to the test voltage and then manually reduced to zero.
10 W ARNING! The motor will automatically start when the AC line is applied or a fault is cleared, if Jumper J4 is set to the “ AUT O ” or “ MAN ” position and the Start/Stop Switch is eliminated. VII. AC LINE FUSING This control does not contain AC line fuses.
11 more rapid deceleration time, rotate the DECEL trimpot coun- terclockwise. For longer deceleration time, rotate the DECEL trimpot clockwise. See Figure 20. Note: T o provide increased resolution of the ACCEL and DECEL trimpots, 50% rotation covers 0.
12 The CL trimpot is factory set for 160% of Jumper J3 range setting. For a higher current limit setting, rotate the CL trimpot clockwise. For a lower current limit setting, rotate the CL trimpot counterclockwise. The current limit also contains I 2 t trip function.
IX. DIAGNOSTIC LEDs The motor control is designed with LEDs mounted on the front cover to display the control’s operational status. A . Power On (ON) – Indicates the presence of bus voltage.
(A40299) – Rev . A – 3/2001 XI. LIMITED W ARRANTY For a period of 2 years from date of original purchase, BALDOR will repair or replace without charge controls which our examination proves to be defective in material or workmanship.
An important point after buying a device Baldor Series 5 Inverter IP-65 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Baldor Series 5 Inverter IP-65 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Baldor Series 5 Inverter IP-65 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Baldor Series 5 Inverter IP-65 you will learn all the available features of the product, as well as information on its operation. The information that you get Baldor Series 5 Inverter IP-65 will certainly help you make a decision on the purchase.
If you already are a holder of Baldor Series 5 Inverter IP-65, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Baldor Series 5 Inverter IP-65.
However, one of the most important roles played by the user manual is to help in solving problems with Baldor Series 5 Inverter IP-65. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Baldor Series 5 Inverter IP-65 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center