(J-30/30SDI) (J-30/30SDI)
OPERATION MANUAL [English] 1st Edition (Revised 1)

To prevent fire or shock hazard, do not expose the unit to rain or moisture.
To avoid electrical shock, do not open the cabinet. Refer servicing to qualified personnel only.
THIS APPARATUS MUST BE EARTHED.

This symbol is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
ONLY. If used in USA, use the UL LISTED power cord specified below. DO NOT USE ANY OTHER POWER CORD.
This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
Plug Cap Parallel blade with ground pin (NEMA 5-15P
Configuration) Cord Type SJT, three 16 or 18 AWG wires Length Minimum 1.5m Rating Minimum 10A, 125V
Using this unit at a voltage other than 120V may require the use of a different line cord or attachment plug, or both. To reduce the risk of fire or electric shock, refer servicing to qualified service personnel.
COUNTRIES. 1. Use the approved Power Cord (3-core mains lead) / Appliance Connector / Plug with earthing-contacts that conforms to the safety regulations of each country if applicable. 2. Use the Power Cord (3-core mains lead) / Appliance Connector / Plug conforming to the proper ratings (Voltage, Ampere).
If you have questions on the use of the above Power Cord / Appliance Connector / Plug, please consult a qualified service personnel.

Afin d’éviter tout risque d’incendie ou d’électrocution, ne pas exposer cet appareil à la pluie ou à l’humidité.
Afin d’écarter tout risque d’électrocution, garder le coffret fermé. Ne confier l’entretien de l’appareil qu’à un personnel qualifié.
Do not install the appliance in a confined space, such as book case or built-in cabinet.
CET APPAREIL DOIT ETRE MIS A LA TERRE.
AVERTISSEMENT: 1. Utiliser le cordon d’alimentation approuvé (conducteur à trois noyaux)/connecteur pour appareils approuvé / fiche avec contacts de mise à la terre approuvée, qui est conforme aux règles de sécurité de chaque pays, si applicable. 2. Utiliser un cordon d’alimentation (conducteur à trois noyaux)/connecteur pour appareils/fiche avec contacts de mise à la terre conforme aux valeurs nominales correctes (tension, ampérage).
For the customers in the USA
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Pour toute question concernant l’emploi du cordon d’alimentation/connecteur pour appareils/fiche ci-dessus, consulter un agent de service compétent.
Il y a un risque d’explosion si la pile est mal insérée. Remplacer la pile uniquement par une pile de même type ou de type équivalent recommandé par le fabricant. Jeter les piles usées conformément aux instructions du fabricant.
You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment.
The shielded interface cable recommended in this manual must be used with this equipment in order to comply with the limits for a digital device pursuant to Subpart B of Part 15 of FCC Rules.
Eviter d’exposer l’appareil à un égouttement ou à des éclaboussures et ne placer aucun objet rempli de liquide, comme un vase, sur l’appareil.
Ne pas installer l’appareil dans un endroit confiné, par exemple une bibliothèque ou un placard encastré.
Cet appareil n’est pas déconnecté de la source d’alimentation secteur tant qu’il est raccordé à la prise murale, même si l’appareil lui-même a été mis hors tension.


Overview
1-1 Before Using
When using this unit for the first time, set the number of scan lines to the NTSC (525 scan lines, field frequency 60 Hz) system setting or to the PAL (625 scan lines, field frequency 50 Hz) system setting according to the operating environment in which the unit will be used. Otherwise, it will be impossible to use this unit.
2 Holding down the JOG/SHUTTLE button, turn the JOG/SHUTTLE dial to display “525” or “625” next to “SEL”.
3 Press the SET/MENU button.

Indication “PUSH SET” appears in the time data display area.
4 Turn the POWER switch off, and then on again.
The indication in the time data display area changes as shown in the figure below.
1 Turn the POWER switch on.
You can see “POWER OFF/ON” by scrolling the indication.
This unit is set for the 525/60 or 625/50 system and indicator 525 or 625 lights above the time data display area to show the selected system.
When you turn on this unit for the first time, indication, “SEL ” appears in the time data display area.
Chapter 1 Overview 1-1
Chapter 1 Overview

The J-10/10SDI/30/30SDI (also referred to simply as the unit(s) in this manual) are compact players based on the 1/2-inch tape format. They play tapes recorded in conventional Betacam/ Betacam SP format.
The unit plays tapes recorded in the Betacam/Betacam SP format. This makes for efficient use of existing material in the Betacam/Betacam SP format.
This unit can be used not only as a Player but also as a Feeder. Connected to a PC, the unit controls images and feeds images to the PC via a remote connector (RS-422A) on the control panel.
The following are some of the features of these units.
Compatible format for playback
Since the unit is as compact as a standard desktop personal computer in size, it is ideal for personal use on your desktop. In addition, front loading of both S and L cassettes is standard.
Initial settings for the unit’s operation, interfaces with connected equipment, and so on, can be made by means of menu operations on the front panel of the unit.
In addition to digital playback heads for the Digital Betacam (J-30/30SDI only), MPEG IMX (J-30/30SDI only) and Betacam SX, the unit also has analog playback heads for the analog Betacam SP.
A large-sized fluorescent display is provided to show numerical values including audio level, time code, user bits, error messages, and setup menu information in addition to the current settings and operating status of this unit.
This unit processes digital signals conforming to the 4:2:2 component digital D-1 format. The unit is compatible with the Digital Betacam (J-30/ 30SDI only), the Betacam SX for the MPEG2 4:2:2 P@ML interframe format, and the MPEG IMX (J-30/30SDI only) for the MPEG2 4:2:2 P@ML intraframe format.
The unit is designed to need minimal maintenance, and requires no daily maintenance or checks. A drum and other components have reduced maintenance costs.
Vertical installation
This unit can be installed vertically using the supplied vertical installation stands. The unit can be installed either vertically or horizontally, saving space on your desktop.
Complying with the data rates for the Digital Betacam (J-30/30SDI only), MPEG IMX (J-30/30SDI only) and Betacam SX, this unit achieves playback with both high image and high audio quality.
1-2 Chapter 1 Overview
Chapter 1 Overview

This unit can output digital video/audio signals in DV format compatible with i.LINK1) from the DV output connector.
Chapter 1 Overview 1-3
Chapter 1 Overview


1-4 Chapter 1 Overview
Chapter 1 Overview


DV Computer TC OUTPUT (J-30SDI) Time code reader Note
Chapter 1 Overview 1-5
Chapter 1 Overview

Chapter 2 Location and Function of Parts
2-1 Control Panel

1 Carrying handle Use this handle to carry the unit or to stand the unit vertically.
2 POWER switch Press the side of the POWER switch marked “ON” to turn the unit on. The fluorescent display and indicators in the display section light. Press the side of the POWER switch marked “OFF” to turn the unit off.
Chapter 2 Location and Function of Parts 2-1

3 Cassette compartment Insert an S or L cassette.
button as the factory default settings. While you are pressing the button, the remaining tape time are displayed in the display section.
Chapter 2 Location and Function of Parts
4 Remote control detector Receives the infrared signal from the supplied Remote Commander.
For details on function assignment, see the section “Menu bank operations (basic menu items B01 to B12) “ on page 7-5.
For details on the Remote Commander, see section 4-3 “Using the Remote Commander” on page 4-7.
6 PHONES (headphones) jack and control knob Connect stereo headphones with an impedance of 8 ohms to monitor the sound during playback. The control knob adjusts the volume. It is possible to make a setting so that the output volume from the AUDIO MONITOR connectors is controlled simultaneously. Set AUDIO MONITOR OUTPUT LEVEL, extended menu item 114, to VAR to enable the above feature.
5 PF (programmable function)-1/2 buttons When using the Betacam SX or MPEG IMX format and settting this unit into noiseless mode, use these buttons to perform frame step playback (see page 4-4). To the PF-2 button, you can assign functions that are set in basic menu item 022, PF2 KEYSELECT. Function “tape remain time” is assigned to the PF-2

1 LTC/VITC button This selects the time code displayed in the FL display in the following sequence: LTC1), VITC2). The underline for the LTC or VITC time code setting indicators lights corresponding to the selection.
2-2 Chapter 2 Location and Function of Parts

2 SET/MENU button Use this button for setup menu operations and settings. Press the SET/MENU button while holding down the SHIFT button to display the contents of the setup menu items on the FL display. When the setting is finished, press only the SET/MENU button to fix the settings and return to the normal display.
For the MPEG IMX format (J-30/30SDI)
Output modea) STEREO MONO
Audio channel L R L R
Chapter 2 Location and Function of Parts
Press once CH-1 CH-2 CH-1 CH-1
Press twice CH-3 CH-4 CH-2 CH-2
Press 3 times CH-5 CH-6 CH-3 CH-3
Press 4 times CH-7 CH-8 CH-4 CH-4
For details of setup menu settings and operations, see Chapter 7.
Press 5 times CH-1,2 CH-1,2 CH-5 CH-5
Press 6 times CH-3,4 CH-3,4 CH-6 CH-6
3 AU MON SEL (audio monitor output select)/ DOLBY C NR1) (noise reduction) button Press this button to function the AU MON SEL button. Each press of this button switches the audio channel as listed below. The selected channels are displayed in the display section.
Press 7 times CH-5,6 CH-5,6 CH-7 CH-7
Press 8 times CH-7,8 CH-7,8 CH-8 CH-8
Press 9 times CH-1,2 CH-1,2
Each press of this button switches the mode as in the above sequence.
Press 10 times CH-3,4 CH-3,4
Press 11 times CH-5,6 CH-5,6
Press 12 times CH-7,8 CH-7,8
Press 13 times Each press of this button switches the mode as in the above sequence.
For the Betacam/Betacam SP format
Output modea) STEREO MONO
Audio channel L R L R
a) Set in basic menu item 026 of the setup menu
Press once CH-1 CH-2 CH-1 CH-1
For the Digital Betacam format (J-30/30SDI)
Press twice CH-1,2 CH-1,2 CH-2 CH-2
Press 3 times CH-1,2 CH-1,2
Each press of this button switches the mode as in the above sequence.
Output modea) STEREO MONO
Each press of this button switches the mode as in the above sequence.
Audio channel L R L R
Press once CH-1 CH-2 CH-1 CH-1
Press twice CH-3 CH-4 CH-2 CH-2
a) Set in basic menu item 026 of the setup menu
Press 3 times CH-1,2 CH-1,2 CH-3 CH-3
Press 4 times CH-3,4 CH-3,4 CH-4 CH-4
For the Betacam SX format
Press 5 times CUE
Press 6 times CH-1,2 CH-1,2
Each press of this button switches the mode as in the above sequence.
Output modea) STEREO MONO
Audio channel L R L R
Press 7 times CH-3,4 CH-3,4
Press 8 times Each press of this button switches the mode as in the above sequence.
Press once CH-1 CH-2 CH-1 CH-1
Press twice CH-3 CH-4 CH-2 CH-2
Press 3 times CH-1,2 CH-1,2 CH-3 CH-3
Press 4 times CH-3,4 CH-3,4 CH-4 CH-4
a) Set in basic menu item 026 of the setup menu
Press 5 times CH-1,2 CH-1,2
Each press of this button switches the mode as in the above sequence. Each press of this button switches the mode as in the above sequence.
Press 6 times CH-3,4 CH-3,4
The latest setting for each format is saved in the memory regardless of whether the power has been turned on/off. Therefore, when you play any cassette next time, it will be played back in the format last saved. If there is no cassette in the unit, you can change the audio channel in the format used the last time you ejected the cassette.
a) Set in basic menu item 026 of the setup menu
Chapter 2 Location and Function of Parts 2-3
Press 4 times · Press 7 times

Press this button while holding down the SHIFT button to function the DOLBY C NR button. The DOLBY C NR indicator lights in the display section. When you are using an oxide tape, it switches the Dolby NR C-type system for analog audio on or off. When you are using a metal tape, the Dolby C NR system is automatically switched on, regardless of the setting of this switch.
5 CTL/TC/UB (display switching) button This selects the time data displayed in the fluorescent display in the following sequence: CTL, TC, UB. As the display changes, the corresponding indicators over the fluorescent display also light/go off.
Chapter 2 Location and Function of Parts
Time data display selection and display contents
Value displayed Indicator status
CTL Tape running time (hours, minutes, seconds, frames) computed from the CTL (control) signal recorded on the tape during playback.
CTL indicator lights.
an analog Betacam oxide tape. OFF: Disables the Dolby C NR system for playback
of an analog Betacam oxide tape. The factory default setting is OFF.
TC Playback time code read by the internal time code reader.a)
The TC indicator lights.
4 SHIFT button Hold down this button and press the AU MON SEL/ DOLBY C NR button to enable the DOLBY C NR function. To enable the menu function, press the SET/ MENU button while holding down the SHIFT button. Press the F FWD or REW button while holding down the SHIFT button to do the forward or reverse cue-up of the shot marks 1). These marks are located before and after of the current tape position. In addition, press the PLAY button while holding down the SHIFT button to superimpose the shot data2) (when using the Betacam/Betacam SP/Betacam SX format) or UMID (when using the Digital Betacam/ MPEG IMX format) over the playback image. To clear the shot data or UMID, again press the PLAY button while holding down the SHIFT button.
UB User bit value inserted in the playback time code.a) The UB indicator lights.
a) The LTC/VITC button switches between LTC and VITC.
6 CTL RESET button Press this button to reset a CTL value displayed in the FL display area.
7 FL (Fluorescent) display and indicators These comprise a time data display, an audio monitor display and of indicators. (See the figure on next page.)
For details on UMID, see Chapter 5.
1) Shot marks If you use a camcorder which allows you to use shot marks, you can insert REC START marks or shot marks in the user bits area in advance for easy editing. This is called inserting shot marks. 2) Shot data The information recorded continuously during the process of shooting is called shot data. The contents of the display vary corresponding to the change of shooting conditions (e.g. changing camcorders, shooting on different dates, etc.). If there are any parts that contain no shot data by changing a shooting camcorder, the unit displays blank data.
MODEL NAME DNW 0090 SERIAL NUMBER 010001 DATE 2001.05.11 TIME 12.55.10 CASSETTE NUMBER 0095 SHOT NUMBER 0052 ID1 AAAAAAAAAAAA ID2 BBBBBBBBBBBB ID3 CCCCCCCCCCCC ID4 DDDDDDDDDDDD
Time code at recording
2-4 Chapter 2 Location and Function of Parts


Chapter 2 Location and Function of Parts
Time data display area Normally this displays a CTL count, time code value, or user bit value according to the selection of the CTL/ TC/UB button or LTC/VITC button. When a cassette recorded in the DF mode is played back, the dot by the ❉ mark in the illustration above lights. At this time, the two dots (:) located above the dot disappear. It is also used to display error messages and the setup menus.
For details of the display of the CTL count, time code value, or user bit value, see the explanation given in “5 CTL/TC/ UB button” on page 2-4.
Chapter 2 Location and Function of Parts 2-5

Tape transport indicator area • Tape transport indicator When you press each button in the tape transport control section, the corresponding indicators light. m: REW (rewind) indicator B: PLAY indicator
3 SHUTTLE dial Turn this to carry out playback in the modes shown in the following table. Turn the dial clockwise for forward playback and counterclockwise for reverse playback.
Chapter 2 Location and Function of Parts
After pressing the JOG/SHUTTLE button, turn the JOG dial for playback in jog mode and the SHUTTLE dial for playback in shuttle mode.
Playback modes using the JOG/SHUTTLE dial
Playback mode Operations and functions
Jog Press the JOG/SHUTTLE button once to light “JOG,” then turn the JOG dial, or simply turn the JOG dial without lighting “JOG.” Playback is carried out at a speed corresponding to the rotating speed of the JOG dial. The playback speed range is from –1 to +1 times normal speed. The JOG dial has no detents.
Shuttle Press the JOG/SHUTTLE button twice to light “SHTL,” then turn the SHUTTLE dial, or simply turn the SHUTTLE dial without lighting “SHTL.” Playback is carried out at a speed corresponding to the angular position of the SHUTTLE dial. The playback speed range is as follows.
When using a Digital Betacam tape (J-30/30SDI): –21 to +21 times normal
When using an MPEG IMX tape (J-30/ 30SDI): –32/–38 to +32/+38 times normal speed (NTSC/PAL)
When using a Betacam SX tape: –35
to +35 times normal speed
When using an analog Betacam tape:
–18/–20 to +18/+20 times normal speed (NTSC/PAL)
1 JOG/SHUTTLE button Use this button to toggle between jog mode and shuttle mode when using the JOG dial or SHUTTLE dial. Press this button once for playback in jog mode, or press this button twice for playback in shuttle mode during playback or F FWD/REW. The corresponding “JOG” indicator or “SHTL” indicator lights in the display section.
The SHUTTLE dial has detents at the center position, and at that point a still picture is displayed.
Notes • Normally, you turn the SHUTTLE dial after setting the jog/shuttle mode by pressing the JOG/SHUTTLE button. However, you can also set the jog/shuttle mode simply by turning the dial. (This feature is available when SELECTION FOR JOG/SHUTTLE DIAL ENABLE, extended menu item 101 of the setup menu, is set to DIAL.) In this case, you must reset the SHUTTLE dial to the center position after turning it, otherwise the dial may be moved by vibration and the tape may start running in the shuttle mode during playback.
2 JOG dial Turn this to carry out playback in the modes shown in the table in the right column. Turn the dial clockwise for forward playback and counterclockwise for reverse playback.
2-6 Chapter 2 Location and Function of Parts

4 F FWD (fast forward) button To start fast forwarding the tape, press this button. The F FWD indicator in the display section lights. When you are using a tape containing shot marks, press this button while holding down the SHIFT button to cue-up a shot mark position in the forward direction.
Chapter 2 Location and Function of Parts
5 STOP button To stop playback, press this button. The STOP indicator in the display section lights. If REFERENCE SYSTEM ALARM, extended menu item 105 of the setup menu, has been set to ON, this button flashes when the external reference video signal is not supplied.
6 STANDBY on/off button When a cassette is inserted in the unit and the unit is in the Stop mode, you can toggle the VTR standby mode on and off by pressing this button. In standby mode, the drum rotates and the tape sticks to the drum. As a result, playback starts immediately. If the unit is set to 8 minutes elapse (this value can be varied using STILL TIMER extended menu item 501 of the setup menu) in standby mode, it automatically switches out of standby mode to protect the tape.
4 F FWD button
6 STANDBY on/off button
1 EJECT button Press this button to eject the cassette.
2 REW (rewind) button To rewind the tape, press this button. The REW indicator in the display section lights. When you are using a tape containing shot marks, press this button while holding down the SHIFT button to cue-up a shot mark position in the reverse direction.
3 PLAY button To start playback, press this button. The PLAY indicator in the display section lights. When you are using a Betacam/Betacam SP/Betacam SX tape containing shot data, press this button while holding the SHIFT button to display shot data (see page 2-4). When you are using a Digital Betacam/MPEG IMX tape containing UMID, press this button while holding the SHIFT button to display UMID (see page 5-2). To clear the shot data or UMID, again press this button while holding down the SHIFT button.
Chapter 2 Location and Function of Parts 2-7

Chapter 2 Location and Function of Parts

5 VIDEO OUTPUT connectors 6 AUDIO MONITOR OUTPUT connectors
1 AC IN connector Connects to an AC outlet using the power cord (not supplied).
5 VIDEO OUTPUT connectors COMPOSITE (analog composite video) (SUPER) output connector (phono jack): Outputs an analog
composite video signal. When basic menu item 005, DISPLAY INFORMATION SELECT, of the setup menu is set as anything other than OFF, the output from this connector outputs superimposed character information such as time code, menu settings, or alarm messages. COMPOSITE (analog composite video) (SUPER) output connector (BNC): Outputs an analog
2 RS232C (RS-232C serial interface) connector (D-sub 9-pin) Used to remote-control this unit from an external device provided with a Sony 9-pin remote control interface.
3 REMOTE IN (9P) connector (RS-422A serial interface, 9-pin) Used to remote-control this unit from an external device provided with a Sony 9-pin remote control interface.
composite video signal. When basic menu item 005, DISPLAY INFORMATION SELECT, of the setup menu is set as anything other than OFF, the output from this connector outputs superimposed character information such as time code, menu settings, or alarm messages. S VIDEO output connector (Mini-DIN 4-pin):
4 EXT SYNC (external synchronization) input connector Inputs the reference video signal. However, on this unit, use this for frame synchronization only, not for color subcarrier synchronization.
Outputs an S VIDEO signal.
2-8 Chapter 2 Location and Function of Parts

DV (i.LINK DV) output connector (IEEE1394, 6-pin): Outputs video/audio signals in DV format. When basic menu item 030, i.LINK CHARACTER, of the setup menu is set to ON and basic menu item 005, DISPLAY INFORMATION SELECT is set as anything other than OFF, the output from this connector outputs superimposed character information such as time code, menu settings, or alarm messages.
Chapter 2 Location and Function of Parts
COMPONENT (Y/R–Y/B–Y) output connectors (BNC): Output analog component video signals (Y/
R–Y/B–Y).
6 AUDIO MONITOR OUTPUT connectors Audio monitor (L/R) output connectors (XLR 3-pin, male): Output two (L and R) audio monitor signals according to the setting of the AU MON SEL/DOLBY C NR button on the control panel. Audio monitor (L/R) output connectors (Phono jack): Output two (L and R) audio monitor signals
according to the setting of the AU MON SEL/ DOLBY C NR button on the control panel.
Chapter 2 Location and Function of Parts 2-9

2-2-2 Connector Panel of the J-10SDI/30SDI
Chapter 2 Location and Function of Parts

6 VIDEO OUTPUT connectors 7 AUDIO MONITOR OUTPUT connectors
1 AC IN connector Connects to an AC outlet using the power cord (not supplied).
6 VIDEO OUTPUT connectors COMPOSITE (analog composite video) (SUPER) output connector (phono jack): Outputs an analog
composite video signal. When the basic menu item 005, DISPLAY INFORMATION SELECT, of the setup menu is set as anything other than OFF, the output from this connector outputs superimposed character information such as time code, menu settings, or alarm messages. COMPOSITE (analog composite video) (SUPER) output connector (BNC): Outputs an analog
2 RS232C (RS-232C serial interface) connector (D-sub 9-pin) Used to remote-control this unit from an external device provided with a Sony 9-pin remote control interface.
3 REMOTE IN (9P) connector (RS-422A serial interface, 9-pin) Used to remote-control this unit from an external device provided with a Sony 9-pin remote control interface.
composite video signal. When the basic menu item 005, DISPLAY INFORMATION SELECT, of the setup menu is set as anything other than OFF, the output from this connector outputs superimposed character information such as time code, menu settings, or alarm messages. S VIDEO output connector (Mini-DIN 4-pin):
4 EXT SYNC (external synchronization) input connector Inputs the reference video signal. However, on this unit, use this for frame synchronization only, not for color subcarrier synchronization.
Outputs an S VIDEO signal.
5 TC OUTPUT (time code output) connector (BNC) Outputs the playback time code.
2-10 Chapter 2 Location and Function of Parts

DV (i.LINK DV) output connector (IEEE1394, 6-pin): Outputs video/audio signals in DV format. When basic menu item 030, i.LINK CHARACTER, of the setup menu is set to ON and basic menu item 005, DISPLAY INFORMATION SELECT is set as anything other than OFF, the output from this connector outputs superimposed character information such as time code, menu settings, or alarm messages.
7 AUDIO MONITOR OUTPUT connectors Audio monitor (L/R) output connectors (XLR 3-pin, male): Output two (L and R) audio monitor signals according to the setting of the AU MON SEL/DOLBY C NR button on the control panel. Audio monitor (L/R) output connectors (Phono jack): Output two (L and R) audio monitor signals
Chapter 2 Location and Function of Parts
according to the setting of the AU MON SEL/ DOLBY C NR button on the control panel.
SDI (serial digital interface) output connector:
Outputs a video/audio signal in D1 format without superimposed character information. SDI (serial digital interface) (SUPER) output connector: Outputs a video/audio signal in D1
format. When basic menu item 005, DISPLAY INFORMATION SELECT, of the setup menu is set as anything other than OFF, the connector outputs the superimposed character information such as time code, menu settings, or alarm messages.
Chapter 2 Location and Function of Parts 2-11

Preparations
3-1 Installation
You can install this unit horizontally as well as vertically. However, it is necessary to use the supplied vertical installation stands to prepare the unit for vertical installation as shown in the figure.
Chapter 3 Preparations 3-1
Chapter 3 Preparations · Vertical installation stands

Removing slack from the tape Press one of the reels in with a finger, and turn gently in the direction shown by the arrows until there is no slack in the tape.
Ejecting a cassette Press the EJECT button. The cassette is ejected.
Insert or eject a cassette while the unit is powered on.
If the tape slacks inside the unit, pressing the EJECT button may not eject the cassette. For information about how to remove the cassette in such a case, refer to the Maintenance Manual. EJECT button
The cassette is drawn into the unit.
If the message “E10-0000” appears in the time data display area, there is moisture condensation in the unit. For steps to take when “E10-0000” is displayed, see section 8-3 “Moisture Condensation” on page 8-2.
3-2 Chapter 3 Preparations
Chapter 3 Preparations · Inserting a cassette · S cassette

Playback
4-1 Playback Procedures
If you play back to the end of the tape The tape is automatically rewound, and stops (when AUTO REWIND, extended menu item 125, is set to ENA).

When using the Dolby C NR system When using an analog Betacam cassette, you can use Dolby C NR for audio playback. To activate the Dolby NR system, press the AU MON SEL/DOLBY C NR button while holding down the SHIFT button on the control panel.
Insert a cassette beforehand.
For details of how to insert a cassette, see the section “Inserting and ejecting cassettes” on page 3-2.
To start playback Press the PLAY button.
To stop playback Press the STOP button.
Chapter 4 Playback 4-1
Chapter 4 Playback

4-1-2 Playback in Jog Mode
4-1-3 Playback in Shuttle Mode


In jog mode, the JOG dial controls the playback speed based the speed at which the dial is turned. The playback speed range is ±1 times normal speed. Use the following procedure to carry out playback in jog mode. 1 Turn the JOG dial directly or press the JOG/ SHUTTLE button to light the JOG indicator.
Pressing the JOG/SHUTTLE button toggles between jog mode and shuttle mode. 2 Turn the JOG dial in the desired direction, at a speed corresponding to the desired playback speed.
+ indicates forward direction speed, – indicates reverse direction speed.
The SHUTTLE dial has detents at the center position, move the SHUTTLE dial to the center indent to display a still picture. Use the following procedure to carry out playback in shuttle mode. 1 Turn the SHUTTLE dial directly or press the JOG/ SHUTTLE button twice to light the SHTL indicator.
Playback in jog mode starts. 3 To stop playback in jog mode, stop turning the JOG dial.
It is possible to make pressing the JOG/SHUTTLE button to switch between JOG and SHUTTLE mode. Select “KEY” in SELECTION FOR JOG/ SHUTTLE DIAL ENABLE, extended menu item 101, to enable the above feature. (This is the default setting.)
If the SHUTTLE dial points to a position other than the center, playback in shuttle mode starts at a speed corresponding to the angular position of the dial.
Pressing the JOG/SHUTTLE button toggles between jog mode and shuttle mode.
4-2 Chapter 4 Playback
Chapter 4 Playback

2 Turn the SHUTTLE dial to the angle corresponding to the desired playback speed.
Playback in shuttle mode starts. 3 Return the SHUTTLE dial to the center indent position or press the STOP button to cancel shuttle mode playback.
When you are using the Betacam SX or MPEG IMX format, you can put this unit into noiseless mode for noiseless jog and shuttle playback at up to ±0.5 times normal speed. During noiseless playback, audio is muted for the MPEG IMX format. For the Betacam SX format, discontinuous audio in frame units is heard. In noiseless mode, you can use the PF-1/2 buttons to step through frames. The step for the MPEG IMX format is 1 frame. The step for the Betacam SX format is 2 frames.
It is possible to make pressing the JOG/SHUTTLE button to switch between JOG and SHUTTLE mode. Select “KEY” in SELECTION FOR JOG/ SHUTTLE DIAL ENABLE, extended menu item 101, to enable the above feature. (This is the default setting.)
To return to normal-speed playback Press the PLAY button.
In the setup menu, set basic menu item 025, NOISELESS to Enable. (The factory default setting is Disable.) JOG or SHTL flashes in the display section.
To alternate between normal-speed playback and shuttle mode playback Set the SHUTTLE dial to the position corresponding to the desired shuttle playback speed first. Press the PLAY button, and then press the JOG/SHUTTLE button twice. For intermittent shuttle mode playback, press the STOP button first and then press the JOG/ SHUTTLE button twice.
Put the unit into noiseless mode, press the JOG or SHUTTLE button, and rotate the JOG/SHUTTLE dial. This allows you to perform noiseless playback at up to ±0.5 times normal speed. In noiseless mode, the emphasis is on slow-speeds. Therefore the SHUTTLE dial speed settings change from the Normal (0), ±0.03, ±0.12, ±0.5, ±1, ±2, ±10, ±35 (Betacam SX format) (15 steps) to 0, ±0.03, ±0.06, ±0.12, ±0.25, ±0.5, ±1, ±10 (15 steps). For the MPEG IMX format, extended menu item 922 of the setup menu IMX NOISELESS PB SELECT allows you to set the playback picture to FRAME, FIELD 1, or FIELD 2 (the factory default setting is FRAME).
Normally, you turn the SHUTTLE dial after setting the jog/shuttle mode by pressing the JOG/ SHUTTLE button. You can also set the jog/shuttle mode, however, by directly turning the dial. (This is available when SELECTION FOR JOG/ SHUTTLE DIAL ENABLE, extended menu item 101, is set to DIAL.) In this case, you must reset the SHUTTLE dial to the center position after turning it, otherwise the dial is moved by vibration and the tape may start running in the shuttle mode during playback.
Chapter 4 Playback 4-3
Chapter 4 Playback

To perform frame step playback
To set the start point and end point of repeat playback
Put the unit into noiseless mode and press the PF-1 or PF-2 button. When you are using the Betacam SX format, each press of the PF-1 button steps 2 frames back, and each press of the PF-2 button steps 2 frames forward. When you are using the MPEG IMX format, the buttons step 1 frame in the same directions.
When a cassette is loaded in the unit, you can specify the current tape position as the start or end point of repeat playback.
To set the start point Holding down the STOP button, press the REW button. The time code (LTC) value of the tape position when the REW button was pressed is stored in memory as the start point time data. When the start point has been set, an asterisk (*) appears to the left of the REPEAT indication in the time data display area.
Indicates that the start point is set.
If no start point is set, the beginning of tape is automatically specified as the repeat playback start point.
You can use the repeat playback function to repeatedly play back a section of the tape defined by setting the start point and end point.
In the setup menu, set extended menu item 142 REPEAT MODE to PLAY. (The factory default setting of this menu item is OFF.) When a cassette is loaded in the unit, the REPEAT indication is displayed in the time data display area for one second at intervals of four seconds. When no cassette is loaded, this indication keeps displayed.
Beginning of tape End point Start point End of tape
If you set the start point at a position after the end point,
Beginning of tape Start point End of tape
the end point data will be deleted.
4-4 Chapter 4 Playback
Chapter 4 Playback

To set the end point Holding down the STOP button, press the F FWD button. The time code (LTC) value of the tape position when the F FWD button was pressed is stored in memory as the end point time data. When the end point has been set, an asterisk (*) appears to the right of the REPEAT indication in the time data display area.
To check the time code of the set start point and end point
Hold down the STOP button and PLAY button simultaneously. As long as you hold down both buttons, the START indication, the start point time code value, the END indication, and the end point time code value are cyclically displayed in this order in the time data display area.
Indicates that the end point is set.
Press the EJECT button to eject the cassette. This deletes both the start point and end point.
If no end point is set, the end of tape is automatically specified as the repeat playback end point.
Beginning of tape End point Start point End of tape
If you set the end point at a position before the start point,
Beginning of tape End point End of tape
the start point data will be deleted.
Press the PLAY button.
Chapter 4 Playback 4-5
Chapter 4 Playback

Displayed items
1 Types of time data
1 Types of time data
2 Drop frame mark of time data
CTL CTL counter data
TCR LTC reader time code
3 VITC field mark
UBR LTC reader user bit
TCR. VITC reader time code
UBR. VITC reader user bit
2 Drop frame mark of time data “ . ”: Drop frame mode “ : ”: Non-drop frame mode
When basic menu item 005 of the setup menu DISPLAY INFORMATION SELECT is set as anything other than OFF, the video signal output from the COMPOSITE (SUPER) output connector, SDI (SUPER) output connector (for J-10SDI/30SDI only) or DV connector contains superimposed character information (overlaid display), including time code, menu settings, or alarm messages.
3 VITC field mark “ ” blank: When displaying Field 1 and 3 “ * ”: When displaying Field 2 and 4
For details on the settings for superimposed display, see DISPLAY INFORMATION SELECT, basic menu item 005 on page 7-7, SDI OUT CHARACTER, basic menu item 027 on page 7-9, and i.LINK CHARACTER, basic menu item 030 on page 7-9.
The basic menu adjusts the position, size and type of the superimposed characters.
Display Operation mode Block A Block B
For details of the basic menu, see section 7-3 “Basic Menu” on page 7-7.
TAPE UNTHREAD Cassette is not loaded.
STANDBY OFF Standby off mode
F.FWD Fast forward mode
PLAY Playback mode (servo unlocked)
PLAY LOCK Playback mode (servo locked)
JOG STILL A still picture in jog mode
JOG FWD Jog mode in forward direction
For details, see section 7-3 “Basic Menu” on page 7-7.
JOG REV Jog mode in reverse direction
SHUTTLE STILL A still picture in shuttle mode
SHUTTLE (Speed) Shuttle mode
4-6 Chapter 4 Playback

Pull off the transparent film covering the battery parts.
When a Remote Commander is used, WIRELESS REMOTE CONTROL, extended menu item 213, must to be set to ON. (It is set to OFF at the factory.) (The following operation is an example of how WIRELESS REMOTE CONTROL is switched from OFF to ON.) 1 Select WIRELESS REMOTE CONTROL, extended menu item 213, to display it.
1 Pull out the lithium battery case.
Pull the battery case toward you while releasing the lock by plucking it with your fingernail.
The illustration shows the information displayed in the time data display area and on the monitor connected to the COMPOSITE (SUPER) output connector, SDI (SUPER) output connector (for J- 10SDI/30SDI only) or DV connector.
Time data display area
2 Set lithium battery in the case so that the + symbol on the battery is facing you.
137 213:WIRELESS-off 501 ❉
3 Push the lithium battery case back into its original position.
Items without ❉ are omitted.
Chapter 4 Playback 4-7
Chapter 4 Playback · Monitor screen

2 Turn the JOG/SHUTTLE dial to change the setting from “OFF” to “ON” while holding down the JOG/ SHUTTLE button, and then release the JOG/ SHUTTLE button.


(ON flashes while the JOG/SHUTTLE button is being pressed.) 3 Press the SET/MENU button.
Time data display area and monitor go back to the original views.
Press the function keys while pointing the infrared transmitter of the Remote Commander at the remote control detector. Each key functions same as the corresponding key on the control panel attached to the unit.
4-8 Chapter 4 Playback
Chapter 4 Playback

UMID Functions
5-1 Overview of UMID Functions
Chapter 5 UMID Functions
The UMID (Unique Material Identifier) is a type of meta-data in video and audio materials. It has been internationally standardized in SMPTE Standard 330M. This unit supports generation of UMIDs recorded in the Digital Betacam or MPEG IMX format. The UMID is made up of a section called the “Basic” section and a section called the “Source Pack” section. The Basic section contains information such as the device that recorded the material and whether the material is the original or a copy. The Source Pack section contains information about when/where/who recorded the material.
A UMID with a Basic section only is called a Basic UMID. A UMID with both Basic and Source Pack sections is called an Extended UMID. The following figure shows a general overview of the information contained in a UMID.
UMID Basic Instance Number
Which device recorded the original
When was it recorded
Where was it recorded
Chapter 5 UMID Functions 5-1

This section explains how to output and display UMIDs.
1 Instance Number Generation Method 2 Instance Number 3 Material Number Generation Method 4, 5 Material Number 6 Year/Month/Date 7 Hour:Minute:Second 8 Time Zone 9 GPS Altitude 0 Number of Satellites qa Auxiliary Device (“ ”: not equiped, “+”: equiped) qs PDOP (Position Dilution Of Precision value) qd Longitude (E: east/W: west) qf Latitude (S: south/N: north) qg Organization Code qh User Code qj Country Code
You can choose to output UMIDs or not from the SDI or SDI (SUPER) output connector, and select either Basic UMID or Extended UMID when you choose to output UMIDs. Make these settings using extended menu item 651, UMID OUTPUT.
See page 7-11 for more information about extended menu item 651.
Chapter 5 UMID Functions
During playback, UMID data appears on the video monitor by superimposition.
Press the PLAY button while holding down the SHIFT button.
To exit from UMID display Press again the PLAY button while holding down the SHIFT button.
During playback in the Digital Betacam format (J-30SDI) or in the MPEG IMX format (J-30/30SDI), the video monitor connected to the COMPOSITE (SUPER) output connector, SDI (SUPER) output connector (for J-30SDI only) or DV connector displays all UMID items at once as shown in the following figure.

5-2 Chapter 5 UMID Functions

Essence Marks
6-1 Overview of Essence Mark Functions
An essence mark uses a term value dictionary item as defined in the SMPTE RP210A Metadata Dictionary to express and transfer points such as recording start points and edit point candidates in up to 32 bytes of data. The basic format of the SMPTE RP210A Metadata Dictionary is defined in SMPTE 336M Data Encoding Protocol using Key-Length-Value (KLV coding specifications).
Chapter 6 Essence Marks
Chapter 6 Essence Marks 6-1

6-2 Essence Mark Output
When playing back a tape, essence marks recorder on the tape can be output to SDI signals. Information such as shot marks recorded on the tape can also be converted into essence marks and output.
You can select whether or not to output essence marks when you play back a tape. Make this selection using extended menu item 657, ESSENCE MARK TAPE OUTPUT.
See page 7-11 for more information about extended menu item 657.
Chapter 6 Essence Marks
You can select whether or not to convert shot marks recorded on a tape into essence marks for output when you play back the tape. Make this selection using extended menu item 658, SHOT MARK ESSENCE MARK CONVERT. When extended menu item 658 is set to ON, you can specify the VANC1) line into which to insert essence marks in extended menu item 660, ESSENCE MARK VANC LINE.
See page 7-11 for more information about extended menu items 658 and 660.
6-2 Chapter 6 Essence Marks

Setup Menu
7-1 Menu System Configuration
The principal setup operations required before operating this unit can be carried out using setup menus. The menu system of this unit is comprised of a basic menu and an extended menu. • Basic menu This menu is used to make the following settings: – the digital hours meter – the character information superimposed on the
Chapter 7 Setup Menu
This unit allows up to two menu settings to be stored in menu banks 1 and 2. The stored menu settings can be called up to use as required.
output to the monitor – settings for switching between the 525 (NTSC) and
625 (PAL) systems – settings for the menu banks for retaining menu
For more information, see “Menu bank operations (basic menu items B01 to B12)” on page 7-5.
Chapter 7 Setup Menu 7-1
settings

7-2 Menu Operations

This section describes the basic menu displays and how to change the settings.
For information about how to use basic menu item 013, see “Switching between 525/625 line systems (basic menu item 013)” on page 7-4, and for information about how to operate items B01 to B12, see “Menu bank operations (basic menu items B01 to B12)” on page 7-5.
For information about how to use the extended menu, see the section “Extended menu operations” on page 7-6.
If the SET/MENU button is pressed while holding down the SHIFT button to display the menu settings in the time data display area, a full-screen version also appears on a monitor connected to the COMPOSITE (SUPER) output connector, SDI (SUPER) output connector (J-10SDI/30SDI only), or DV connector as shown in the above figure.


Chapter 7 Setup Menu
Press the SET/MENU button while holding down the SHIFT button. The setting of the currently selected menu item appears in the time data display area.

Turn the JOG/SHUTTLE dial. Turning the JOG/SHUTTLE dial to the right increments the item number and turning it to the left decrements the item number. The item number changes at a rate depending on the JOG/SHUTTLE dial position (when the SHTL indicator is lit) or on the JOG/SHUTTLE dial rotation rate (when the JOG indicator is lit).
Displaying the menus on the monitor Menu setting can be done on the monitor while superimposing is set to ON.
7-2 Chapter 7 Setup Menu

Resetting the menu settings to their factory default values (basic menu item B20)
To change the setting value of the currently displayed menu item, use the following procedure.


1 Holding down the JOG/SHUTTLE button, turn the JOG/SHUTTLE dial.
1 Set RESET SETUP, basic menu item B20, to ON.
“PUSH SET” appears in the time data display area, and “Push SET button” appears on the monitor screen. 2 Press the SET/MENU button.
The setting value changes at a rate based on the SHUTTLE dial position or on the JOG dial rotation rate.

Chapter 7 Setup Menu
The current active menu settings (see “Menu bank operations (basic menu items B01 to B12)”) are reset to their factory default settings. 3 Press the SET/MENU button again.
The settings are saved and the menu display disappears from the time data display area.
2 When the desired setting value is displayed, press the SET/MENU button.
This saves the new setting value, and the menu display disappears from the time data display area.
To cancel the change Press the SET/MENU button while holding down the SHIFT button before pressing the SET/MENU button only. The menu display disappears from the time data display area without saving the new setting value.
Chapter 7 Setup Menu 7-3

2 Holding down the JOG/SHUTTLE button, turn the JOG/SHUTTLE dial to change the setting from OFF to ON.
Using the following procedure, you can set basic menu item 013, 525/625 SYSTEM SELECT, to ON, and then switch between 525 (NTSC) and 625 (PAL).
The displays change as follows.

(The following is the procedure example of switching from a 525 (NTSC) system to a 625 (PAL) system.) 1 Select basic menu item 013 and display it.
The time data display area and the monitor screen connected the COMPOSITE (SUPER) output connector, SDI (SUPER) output connector (for J-10SDI/30SDI only) or DV connector show the following displays.

3 Press the SET/MENU button.
The displays change as follows.
Chapter 7 Setup Menu

If the 525/625 setting is changed, turn power off and on!
7-4 Chapter 7 Setup Menu

4 Holding down the JOG/SHUTTLE button, turn the JOG/SHUTTLE dial to change the setting from 525 to 625.
This switches from the 525 (NTSC) to the 625 (PAL) system; the 525 indicator goes off, and the 625 indicator lights. The menu settings disappear from the time data display area, and returns to the normal indications.
The displays change as follows.

This unit allows two different complete sets of menu settings to be saved in what are termed “menu banks,” numbered 1 and 2. Saved sets of menu settings are recalled for use as required.
To jump to menu item B01 or H01 The unit recalls any required menu items when you turn the JOG/SHUTTLE dial after pressing the SET/ MENU button while holding down the SHIFT button. Press the SET/MENU button while holding down the SHIFT button, then press the CTL/TC/UB button. Every time you press the CTL/TC/UB button, menu item H01 or B01 is recalled alternately.
To cancel the 525/625 setting operation Holding down the SHIFT button, press the SET/ MENU button the required number of times to exit from the menu. 5 Press the SET/MENU button.
Saving the current active menu settings Set menu item SAVE BANK 1, basic menu item B11, or SAVE BANK 2, basic menu item B12, to ON, depending on which of the menu banks you wish to use to save the setting, then press the SET/MENU button.
Chapter 7 Setup Menu
The displays change as follows.

Recalling settings from a menu bank Set menu item RECALL BANK 1, basic menu item B01, or RECALL BANK 2, basic menu item B02, to ON, depending on which of the menu banks you wish to recall settings from, then press the SET/MENU button.
You can see “POWER OFF/ON” by scrolling the indication.

6 Turn the POWER switch off momentarily, then turn it on again.
Chapter 7 Setup Menu 7-5

Extended menu operations
You can operate the extended menu in the same way as you operate the basic menu.
For details of basic menu operations, see page 7-2.
Chapter 7 Setup Menu
7-6 Chapter 7 Setup Menu

The basic menu contains the following items. In the “Settings” column of the table, the factory
default settings are indicated by an enclosing box.
Item number Item name Settings
002a) CHARACTER H- POSITION
Adjust the horizontal screen position of the character information output from the COMPOSITE (SUPER) output connector, SDI (SUPER) output connector (J- 10SDI/30SDI), or DV connector for superimposed display on the monitor. 00 ... 04 ... 08: The value 00 is for the far left of the screen and 08 for the far right. Increasing the value moves the position of the characters to the right.
003a), b) CHARACTER V- POSITION
Adjust the vertical screen position of the first line of the character information output from the COMPOSITE (SUPER) output connector, SDI (SUPER) output connector (J-10SDI/30SDI), or DV connector for superimposed display on the monitor. 00 ... 11 ... 14 (525 mode)/00 ... 14 ... 17 (625 mode): The hexadecimal value 00 is for the top of the screen and increasing the value lowers the position of the characters. 005 DISPLAY INFORMATION SELECT
Determines the kind of character information to be output from the COMPOSITE (SUPER) output connector, SDI (SUPER) output connector (J-10SDI/30SDI), or
DV connector for superimposed display on the monitor. OFF : Displays no character information. T&STA : Time data display information and the unit’s status. T&UB: Time data display information and the user bits. T&CTL: Time data display information and CTL. T&T: Time data display information and time code (LTC or VITC). TIME: Time data display information only If there is an overlap between the setting of this item and the setting of the control panel, it is automatically avoided. For example, if CTL is selected on the control panel and this menu item setting is T&CTL, CTL and LTC will be output.
007 TAPE TIMER DISPLAY Determines whether to display the CTL counter in 12-hour mode or 24-hour mode. + –12H : 12-hour mode 24H: 24-hour mode
Chapter 7 Setup Menu
009a) CHARACTER TYPE Determines the type of characters such as time code output from the COMPOSITE (SUPER) output connector, SDI (SUPER) output connector (J-10SDI/30SDI), or DV connector for superimposed display on the monitor. WHITE : White letters on a black background. BLACK: Black letters on a white background. W/OUT: White letters with black outlines. B/OUT: Black letters with white outlines.
011a) CHARACTER V-SIZE Determines the vertical size of characters such as time code output from the COMPOSITE (SUPER) output connector, SDI (SUPER) output connector (J-10SDI/30SDI), or DV connector for superimposed display on the monitor. ×1 : Standard size ×2: 2 times standard size
a) When setting items 002, 003, 009 and 011 watch the
b) When displaying time code values, there is a slight time
monitor screen, and adjust to the required state.
delay. Therefore, when creating a tape for off-line editing, the information inserted in the upper half of the screen may be delayed by one frame.
Chapter 7 Setup Menu 7-7

Item number Item name Settings
012 CONDITION DISPLAY ON VIDEO MONITOR (The channel status can be displayed only when the CHARACTER V-SIZE is set to ×1.)
Determines whether or not to display the channel status in addition to the characters being superimposed. disable : Disables display enable: Enables display Displayed channel status The channel statuses are displayed under the timer or status display line. (When an analog tape is inserted, only the playback level of the video is displayed.) e.g. V — A — The letters that follow “V” indicate the status of the video channels of the rotation head. The letters that follow “A” indicate the status of the audio channels of the rotation head. Character patterns –: Good condition *: Acceptable condition x: Bad condition
Specify whether to enable switching between the 525 (NTSC) and 625 (PAL) systems. OFF : Do not enable system switching. ON: Enable system switching. You can choose and set 525 (NTSC) or 625 (PAL) as this unit’s initial operation mode. If the unit is set as 525 (NTSC) mode beforehand, setting this item to ON and switching the system to 625 (PAL) mode enables the unit to operate in 625/50 mode. On the other hand, if the unit is set as 625 (PAL) mode beforehand, setting this item to ON and switching the system to 525 (NTSC) mode enables the unit to operate in 525/60 mode.
For information on how to switch the system or other details, see “Switching between 525/625 line systems (basic menu item 013)” on page 7-4.
020 DROP-FRAME MODE SELECT (When operating in 525 mode)
Determines the drop-frame mode of the CTL counter. DF : Drop-frame mode NDF: Non-drop-frame mode
Chapter 7 Setup Menu
022 PF2 KEY SELECT Determines the function assigned to PF2 button. REM : Displays the remaining tape time by minute. RUN : Displays the total number of times that the tape has been running until then.
Selects the type of characters to superimpose on the video signal (overlaid display) output from the COMPOSITE (SUPER) output connector, SDI (SUPER) output connector (J-10SDI/30SDI), or DV connector. WHITE : White letters on a black background BLACK: Black letters on a white background W/OUT: White letters with black outlines B/OUT: Black letters with white outlines
025 NOISELESS PB MODE Select whether or not to use the noiseless playback function (when using Betacam SX or MPEG IMX format). Disable : Do not use the noiseless playback function. Enable: Use the noiseless playback function. 026 AUDIO MONITOR MODE Select a mode of AUDIO MONITOR. MONO: Monaural + mix STEREO : Stereo + mix
7-8 Chapter 7 Setup Menu

Item number Item name Settings
027 SDI OUT CHARACTER (J-10SDI/30SDI only)
Select whether or not to superimpose the type of characters over the video signal (overlap display) output from the SDI (SUPER) connectors. OFF: Does not superimpose. ON : Superimposes.
030 i.LINK CHARACTER Selects whether or not to superimpose characters on the video signal (overlap display) output from the DV connector. OFF : Does not superimpose. ON: Superimposes.
Item number Item name Settings
099 MENU GRADE Determines the menus that can be changed. BASIC : Basic menu ENHAN: Basic menu + Extended menu B01 RECALL BANK 1 Set to ON to recall current menu settings from menu bank 1.
B02 RECALL BANK 2 Set to ON to recall current menu settings from menu bank 2.
B11 SAVE BANK 1 Set to ON to save current menu settings to menu bank 1.
B12 SAVE BANK 2 Set to ON to save current menu settings to menu bank 2.
B20 RESET SETUP Set to ON to reset current menu settings to factory default values.
Chapter 7 Setup Menu
Chapter 7 Setup Menu 7-9

The extended menu contains the following items. In the “Settings” column of the table, the factory default settings are indicated by an enclosing box.
Item number Item name Settings
Select how the unit enters the jog/shuttle mode. DIAL : Turning the JOG/SHUTTLE dial enters the jog/shuttle mode. KEY : Press the JOG/SHUTTLE button to enter jog/shuttle mode. 102 MAXIMUM TAPE SPEED Set the tape speed for fast-forward, rewind and jog/shuttle mode operations. MAX : Fast forward, rewind and jog/shuttle mode operations are carried out at
and jog/shuttle mode operations are carried out at up to 24 times normal speed. ×24: Fast forward, rewind and jog/shuttle mode operations are carried out at up to
24 times normal speed. Maximum speed for fast forward and rewind
104 AUDIO MUTING TIME Select the length of time for which audio muting occurs when the unit switches to playback either from stopped or from still playback in the jog/shuttle mode. LOCK : Make the audio output signal muted until the servo lock functions. OFF : Set the audio muting time to zero (i.e. no muting). 0.1S ... 1.0S: Set the audio muting time from 0.1 seconds to 1.0 second, in 0.1- second increments.
Chapter 7 Setup Menu
Select whether or not to display a warning when the video/audio reference signal is not supplied. OFF : No warning. ON : Flash the STOP indicator as a warning.
Choose whether or not to permit changes in the audio monitor output level from the control panel (which can simultaneously be monitored via the headphone jack) using the volume control knob on the control panel. FIXED : Output level changes not permitted. VAR: Output level changes permitted.
125 AUTO REWIND Determine whether or not to rewind the tape automatically when playback reaches the end of a tape. DIS: Do not rewind automatically. ENA : Rewind automatically.
Set the brightness of the time data/menu display. 0 to 3 : The brightness can be set within this range. 3 is the brightest and 0 is the darkest. 137 TRACKING CONTROL VIA JOG/SHUTTLE DIAL
Select the tracking control in the JOG/SHUTTLE dial. OFF : Disables tracking control. ON: Enables tracking control by turning the JOG/SHUTTLE dial in the PLAY
mode. (When this item is set to ON, the JOG and SHTL indicators in the display section flash.)
142 REPEAT MODE Select whether or not to put the unit into repeat playback mode.
OFF: Do not put the unit into repeat playback mode. PLAY: Put the unit into repeat playback mode.
Select control mode with the infrared Remote Commander. OFF : Do not operate. ON: Operate.
7-10 Chapter 7 Setup Menu

Item number Item name Settings 501 STILL TIMER Sets the time interval from the tape stop mode to the tape protection mode. In order to protect the video heads and the tape, this unit enters the tape protection mode automatically after a certain amount of time has elapsed since the unit entered the tape stop mode (STOP mode or a still picture in jog/shuttle mode). 0.5S ... 8M ... 30M: Set the value in the range 0.5 seconds to 30 minutes.
651 UMID OUTPUT (J-30SDI only)
When using the Digital Betacam or MPEG IMX format, select whether or not to output the UMID data recorded on the tape from the SDI output connector and the type of the UMID data if it is output. OFF : Do not output the UMID data. BASIC: Output as the Basic UMID data (32 byte). EXTENDED: Output as the Extended UMID data (64 byte).
657 ESSENCE MARK TAPE OUTPUT (J-30SDI only)
When using the Digital Betacam or MPEG IMX format, select whether or not to output essence marks recorded on the tape from the SDI output connector. ON: Output essence marks recorded on the tape. OFF : Do not output essence marks recorded on the tape.
658 SHOT MARK ESSENCE MARK CONVERT (J-10SDI/30SDI only)
When using the Digital Betacam, MPEG IMX or Betacam SX format, select whether or not to convert shot marks recorded in the LTC track into essence marks and output them from the SDI output connector. ON: Convert shot marks into essence marks and output. OFF : Do not convert shot marks into essence marks. Depending on the type of the detected shot marks, the output essence marks are “_RecStart”, “_ShotMark1”, or “_ShotMark2”.
Chapter 7 Setup Menu
660 ESSENCE MARK VANC LINE (J-10SDI/30SDI only)
When menu item 658 is set to ON, specify the line into which to insert shot marks converted into essence marks. 12H, 13H, 15H, 16H, 17H , 18H, 19H (525-line mode) 09H, 10H, 12H, 13H, 14H, 15H, 16H, 17H , 18H (625-line mode)
Select the test signal to be output from the VTR’s internal test signal generator. OFF : No test signal is generated. (The VTR operates normally.) CB75: 75% color bar signal
713a) VIDEO SETUP REFERENCE LEVEL (When operating in 525 mode)
Set the setup amount to be added to the composite output signal. Default value: 0.0%
7.5%
715a) VIDEO GAIN CONTROL Adjust the video output level. Only Y signal adjustment is permitted. Default value: 20H
716a) CHROMA GAIN CONTROL
Adjust the chroma output level. Default value: 20H
717a) CHROMA PHASE CONTROL
Adjust the chroma phase. Only composite output signal adjustment is permitted. Default value: 80H
718a) SETUP LEVEL (525 mode)/ BLACK LEVEL (625 mode)
Adjust the setup level (black level). Default value: 0H
a) Menu items 713 and 715 to 718 can be used only for
video processing of the analog video signal. They cannnot be used for video processing of the digital video signal (SDI/DV output).
Chapter 7 Setup Menu 7-11

Item number Item name Settings
719 SYSTEM PHASE SYNC Adjust the SYNC phase of the output signal. Default value: 3FH
721 Y/C DELAY Adjust the Y/C delay for playback from an analog Betacam cassette. Default value: 800H
Set the digital audio muting conditions during shuttle playback. OFF : Not muted. CUEUP: Muted during cue-up or preroll operations. FULL: Muted in shuttle mode. SLOW: Muted in ±0.2 times or slower.
Select the operation of the internal audio test signal generator. OFF : No operation. 1KHZ: At 1 kHz, –20 dB FS sine wave is output on all audio output channels. 831a) i.LINK AUDIO OUTPUT SELECT
Selects audio channels output from the DV connector. CH1/2 : Outputs audio signals (16 bits/48K) recorded in CH-1/2. CH3/4: Outputs audio signals (16 bits/48K) recorded in CH-3/4. CH1/2/3/4: Outputs audio signals (12 bits/32K) recorded in CH-1/2/3/4. CH5/6: Outputs audio signals (16 bits/48K) in CH-5/6 (J-30/30SDI). CH7/8: Outputs audio signals (16 bits/48K) in CH-7/8 (J-30/30SDI). CH5/6/7/8: Outputs audio signals (12 bits/32K) in CH-5/6/7/8 (J-30/30SDI).
901b) VIDEO OUTPUT DATA (J-10SDI/30SDI only)
Set the bit length of the signal output from the SDI output connector. 10bit : When connecting to a 10-bit system 8bit: When connecting to a 8-bit system
922 IMX NOISELESS PB SELECT (J-30/30SDI only)
Select the noiseless playback picture output when using the MPEG IMX format. FRAME : Frame picture FIELD1: Field 1 picture FIELD2: Field 2 picture
a) Audio signals are muted if you select the channel
Chapter 7 Setup Menu
unavailable for the format you are using. b) Select the bit length used in the system to which this unit
is connected.
7-12 Chapter 7 Setup Menu

Maintenance and Inspection
8-1 Removing a Cassette When Tape Slack Occurs
If tape slack occurs in the unit, it is necessary to remove the top and bottom plates. This job should always be entrusted to a technician who has undergone service training.
See the maintenance manual for details.
Chapter 8 Maintenance and Inspection
To clean the video heads and audio heads, always use the special-purpose Sony BCT-HD12CL cleaning cassette. Follow the instructions with the cleaning cassette carefully, as inappropriate use of the cleaning cassette can damage the heads.
To carry out head cleaning Insert the cleaning cassette. Head cleaning starts. After an automatic head cleaning operation which lasts for about 3 seconds, the cleaning cassette is automatically ejected.
Chapter 8 Maintenance and Inspection 8-1

When the unit is suddenly moved from a cold to a warm location, or used in a very humid place, moisture from the air can condense on the head-drum. This is called moisture condensation. If the tape is run in this state, it can adhere to the drum. To prevent such a condition from occurring, the unit is provided with a moisture condensation detecting function.
If moisture condenses on the head-drum while the unit is in use, the ALARM indicator flashes and “E10- 0000” is displayed in the time data display area.

“E10-0000” is displayed in the time data display area.
If this happens, the drum and capstan motors stop and the cassette is automatically ejected. Then, the drum starts to rotate again to dry its surface. In this state, the unit is not operable. When the moisture has evaporated, the ALARM indicator goes off and the “E10-0000” message disappears.
Chapter 8 Maintenance and Inspection
If the ALARM indicator lights and “E10-0000” appears immediately after powering the unit on Leave the unit powered on and wait until the ALARM indicator goes off and the error message disappears. Do not insert a cassette while the indicator is lit. Use the unit when the indicator goes off and the error message disappears.
If you move the unit from a cold to a warm location Leave the unit powered off for about 10 minutes, in order to give the unit time to detect moisture condensation.
8-2 Chapter 8 Maintenance and Inspection

01 REEL TROUBLE Detected “tape slack” during threading or unthreading.
02 REEL TROUBLE Detected “tape slack” or “tape break” during search, fast-forward, or rewind.
03 REEL TROUBLE Detected “tape slack,” “tape break,” or “reel rock in the S-side or T-side” during playback.
04 REEL TROUBLE Detected abnormal tape speed during fast-forward or rewind.
05 REEL TROUBLE Detected abnormal operation on the S-side or T-side reel during cassette compartment operation.
06 TAPE TENSION Detected excessive tape tension during playback.
07 CAPSTAN TROUBLE Detected abnormal operation of capstan motor.
08 DRUM TROUBLE Detected abnormal operation of drum motor.
09 TH/UNTH MOTOR Detected abnormal operation during threading or unthreading.
0A THREADING Detected incorrect ending of process for tape top when threading.
10 HUMID Detected moisture condensation.
11 TAPE T/E SENSOR Detected tape top and tape end simultaneously.
12 TAPE TOP SENSOR Detected abnormal condition in tape top sensor.
13 TAPE END SENSOR Detected abnormal condition in tape end sensor.
20 CASS COMP MOTOR Detected abnormal condition during cassette compartment operation.
92 INTERNAL I/F ERROR Detected abnormal condition in communication between SYS CPU and other CPU/MPUs.
96 SY NV-RAM ERROR Detected abnormal operation in a system control device, NV-RAM.
97 SV NV-RAM ERROR Detected abnormal operation in a servo system device, NV-RAM.
98 RF NV-RAM ERROR Detected abnormal operation in an RF system device, NV-RAM.
Chapter 8 Maintenance and Inspection
Chapter 8 Maintenance and Inspection 8-3

The digital hours meter can display nine items of information, in corresponding display modes, about the operational history of the unit. Use it as a guide in scheduling periodic maintenance.
H16:REEL SHIFT mode (resettable) Same as H06 except that the count is resettable.
Display modes of the digital hours meter

The digital hours meter has the following nine modes.
H01:OPERATION mode Displays the total number of hours the unit has been powered on in units of 1 hour.
H02: DRUM RUNNING mode Displays the total number of hours the drum has run with tape threaded in units of 1 hour.
H03:TAPE RUNNING mode Displays the total number of hours the unit has been in fast forward, rewind, playback, or search (except for stop and still) mode in units of 1 hour.
To display the digital hours meter Press the SET/MENU button while holding down the SHIFT button, then turn the JOG/SHUTTLE dial to display the required item in the time data display area.
H04:THREADING mode Displays the total number of times the tape has been threaded/unthreaded.
H06:REEL SHIFT mode Displays the total number of times that the reel has been shifted according to the size of the cassette (L cassette or S cassette) in use.
To jump to H01 Press the SET/MENU button while holding down the SHIFT button, then press the CTL/TC/UB button. Every time you press the CTL/TC/UB button, menu item H01 or B01 is recalled alternately.
Chapter 8 Maintenance and Inspection
H12:DRUM RUNNING mode (resettable) Same as H02 except that the count is resettable. By resetting the cumulative drum running time after changing the rotating head drum, this count can be used as a guide in determining when to replace the drum.
To exit from the digital hours meter Press the SET/MENU button.
H13:TAPE RUNNING mode (resettable) Same as H03 except that the count is resettable. This count can be used as a guide in determining when to replace such components as fixed heads and pinch rollers.
H14:THREADING mode (resettable) Same as H04 except that the count is resettable. This can be used as a guide in determining when to replace, for example, the threading motor.
8-4 Chapter 8 Maintenance and Inspection

Specifications
100 to 240 VAC, 50/60 Hz Power consumption
124 minutes (BCT-D124L cassette) MPEG IMX (J-30/30SDI)
55 W Rated current 0.55 A Peak inrush current
10 A (100 V) (2)Hot switching inrush current, measured in
cassette) Betacam SX 194 minutes (BCT-194SXLA cassette) Analog Betacam
accordance with European standard EN55103-1: 15 A (230 V) Operating temperature
5 °C to 40 °C (41 °F to 104 °F) Storage temperature
–20 °C to +60 °C (–4 °F to +140 °F) Humidity 25% to 80% Mass J-10/10SDI: 8.1 kg (17 lb 13 oz) J-30/30SDI: 8.2 kg (18 lb 1 oz) Dimensions (w/h/d)
cassette) Fast forward/rewind time
Approx. 5 minutes with
BCT-194SXLA cassette Search speed
307 × 100 × 397 mm (12 1/8 × 4 × 15 3/4 inches)
times (NTSC)/±20 times (PAL) normal speed playback Betacam SX playback: Still to ±35
times normal speed playback MPEG IMX playback (J-30/ 30SDI): Still to ±32 times (NTSC)/ ±38 times (PAL) normal speed playback Digital Betacam playback (J-30/
96.7 mm/s MPEG IMX (J-30/30SDI)
30SDI): Still to ±21 times normal speed playback Jog mode Still to ±1 times normal playback

Servo lock time (from standby)
S/N 56 dB or more K factor (2T pulse)
1.5 second or less Load/unload time 7 seconds or less Cassette types Digital Betacam cassette (J-30/
30SDI) MPEG IMX cassette (J-30/30SDI) Betacam SX cassette Betacam SP cassette Betacam cassette UVW cassette
Digital audio signal format Betacam SX, Digital Betacam (J-30/30SDI): CH-1 -
48 kHz (synchronized with video) Quantization 16 bits/ sample or 20 bits/sample Wow and flutter Below measurable level Headroom 20 dB (or 18 dB, 16 dB selectable) Emphasis T1= 50 µs, T2=15 µs
Digital video signal system Sampling frequency
Y: 13.5 MHz R–Y/B–Y: 6.75 MHz Quantization Digital Betacam (J-30/30SDI): 10
Analog output A/D, D/A quantization
16 bits/sample or 20 bits/sample Frequency response
20 Hz to 20 kHz +1 dB/ –1.5 dB (0 dB, 1 kHz) Dynamic range 85 dB or more (at 1 kHz, emphasis on) Distortion 0.1% or less (at 1 kHz, emphasis on, reference level (+4 dBm)) Crosstalk –75 dB or less (at 1 kHz, between
MPEG2 4:2:2 P@ML Channel coding S-I-NRZI PR-IV Error correction Reed-Solomon code
–3.0 dB (PAL) S/N 53 dB or more Differential gain 2% or less Differential phase 2° or less K factor (2T pulse)
Output connectors COMPOSITE (SUPER)
1% or less Y/C delay 25ns or less
BNC (1), Phono jack (1), including
character superimposition 1.0 Vp-p, 75 Ω, Sync negative COMPONENT BNC (3), Y: 1.0 Vp-p, R–Y/B–Y:
Analog component output Bandwidth
0.7 Vp-p, 75 Ω S VIDEO Mini-Din 4 pin (1), Y: 1.0 Vp-p,
MPEG IMX/Digital Betacam format (J-30)
Y: 0.5 to 5.75 MHz +0.5 dB/
C: 0.286 Vp-p burst, 75 Ω DV IEEE1394 (1), 6-pin PHONES JM-60 stereo phone jack –∞ to –12 dBu at 8 Ω load,
–4.5 dB Betacam SX format (J-10/30)
unbalanced AUDIO MONITOR OUTPUT (L/R)
Y: 0.5 to 4.5 MHz +0.5 dB/–4.5 dB
Phono jack (2), unbalanced XLR 3-pin, male (2) +4 dBm at 600 Ω load, low
–4.5 dB

Remote connectors RS232C D-sub 9-pin, male, Sony 9-pin
Remote Interface REMOTE IN (9P) D-sub 9-pin, female, Sony 9-pin
Input connector EXT SYNC BNC (1), Frame lock
Output connectors COMPOSITE (SUPER)
BNC (1), Phono jack (1), including
character superimposition 1.0 Vp-p, 75 Ω, Sync negative SDI BNC (1), SMPTE 259M, 270 Mb/s,
0.8 Vp-p, 75 Ω SDI (SUPER) BNC (1), SMPTE 259M, 270 Mb/s,
Design and specifications are subject to change without notice.
0.8 Vp-p, 75 Ω, including character superimposition S VIDEO Mini-Din 4 pin (1), Y: 1.0 Vp-p,
C: 0.286 Vp-p burst, 75 Ω DV IEEE1394 (1), 6-pin TC OUTPUT BNC (1), 1.0 Vp-p, 75 Ω PHONES JM-60 stereo phone jack –∞ to –12 dBu at 8 Ω load,
unbalanced AUDIO MONITOR OUTPUT (L/R)
Phono jack (2), unbalanced XLR 3-pin, male (2) +4 dBm at 600 Ω load, low
Remote connectors RS232C D-sub 9-pin, male, Sony 9-pin
Remote Interface REMOTE IN (9P) D-sub 9-pin, female, Sony 9-pin
Input connector EXT SYNC BNC (1), Frame lock
Operation Manual (CD-ROM) (1) Operation Manual (1) Vertical installation stands (2) RM-J1 Remote Commander (with CR2025 Lithium

The material contained in this manual consists of information that is the property of Sony Corporation and is intended solely for use by the purchasers of the equipment described in this manual. Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation.

30/30SDI (SY)
B & P Company
3-826-997-02(1) 2004
Owners and our team usually reply within a day — and your question helps the next person too.