Precautions 32 Phenomena Specific to CCD Image Sensors 33
Features 34 Supplied Accessories 34 Location and Functions of Parts and Controls 35
Camera 35
Installing the Camera 38
Installing the Camera on a
Desk 38 Attaching the Camera to a
Tripod 38 Installing the unit on the
ceiling 38 Installing the Camera Using the M3
Fixing Screw Holes 42 Connections 42
Connecting to an AC Outlet 42 Connecting a Computer 43 Connecting a video monitor or VTR
equipped with a composite or S video input connector 44
Message List 45 Troubleshooting 46 Specifications 47
Using the VISCA RS-422 connector
pin assignments 50

maintenance. If abnormal noise occurs, consult your Sony dealer.
Ventilation To prevent heat buildup, do not block air circulation around the camera.
Transportation When transporting the camera, repack it as originally packed at the factory or in materials equal in quality.
Maintenance The camera mechanism may cause abnormal noise due to wear and lubrication loss after a long period of use. To maintain optimum performance, we recommend periodical
B Getting Started

The following phenomena that may appear in images are specific to CCD (Charge Coupled Device) image sensors. They do not indicate malfunctions.
White flecks Although the CCD image sensors are produced with high-precision technologies, fine white flecks may be generated on the screen in rare cases, caused by cosmic rays, etc. This is related to the principle of CCD image sensors and is not a malfunction.
This phenomena may be improved by turning the camera off and then on again.
Aliasing When fine patterns, stripes, or lines are shot, they may appear jagged or flicker.
Getting Started

Supplied Accessories
When you unpack, check that all the supplied accessories are included.
Ceiling bracket (A) (1)
Ceiling bracket (B) (1)
B Overview · Camera (1)



Screw +M 3×8 (8)

VISCA RS-422 connector plug (1)

Lights when the camera is turned on. It takes about 7 to 16 seconds to display the image after the lamp lights.
Lights when the camera is set to standby mode.

H VISCA RS-422 connector
To communicate via RS-422, use this connector. Use the supplied VISCA RS-422 connector plug.

J S VIDEO(output) connector
K VISCA IN connector
Connect to a computer via an RS-232C interface. When you connect multiple cameras, connect it to the VISCA OUT connector of the previous camera in the daisy chain connection.
L VISCA OUT connector
When you connect multiple cameras, connect it to the VISCA IN connector of the next camera in the daisy chain connection.
M DC 12 V connector
Use only the polarity plug (standard JEITA/type 4).
F IMAGE FLIP switch
Flips the image upside down. Normally set this to OFF when you use the camera. When the camera is attached to the ceiling, set this to ON. Before you set the IMAGE FLIP switch, turn off the unit (or set to standby mode) and then, turn the power on by connecting the power adaptor, by VISCA control or the remote commander. When you switch this, the preset setting is returned to the initial setting. It takes about 7 to 16 seconds for the image displayed to respond to the setting change.
Polarity of the plug
G IR SELECT switch
Select the camera number when you operate multiple cameras with the same remote commander.
Rear · I VIDEO(output) connector · E Remote sensors

Setting of the BOTTOM switches
A D70 mode switch
Set to ON to use the VISCA command for EVI-D70/D70P.
B IR OUT switch
Set to ON to enable output of the receiver signals, which are transmitted from the infrared remote commander via the VISCA IN connector (page 50), or set it to OFF to disable the output.
C RS-232C/RS-422 select switch
Set to ON to operate colour video camera using the VISCA command via the RS-422 interface. To change the mode, turn off the camera (not including standby mode) first, set the switch and then turn on the camera again. Mode switching is not possible while the camera is turned on.
N Tripod screw hole
Used for RS-232C and RS-422 switching, 9,600 bps and 38,400 bps baud rate selection, D70 mode switching and IR signal output setting. For detailed information, refer to the Technical Manual of the camera.
D Baud rate select switch
Set to ON for 38,400 bps or OFF for 9,600 bps. To change the mode, turn off the camera (not including standby mode) first, set the switch and then turn on the camera again. The mode cannot be switched while the camera is turned on.
P Ceiling bracket mounting screw
E Switch 5 (Not used)
Be sure to set this switch to OFF.
Bottom · Overview · O BOTTOM switches

B Installation and Connection
Attach a tripod to the screw hole used for attaching a tripod on the bottom of the camera. The tripod must be set up on a flat surface and its screws tightened firmly by hand. Use a tripod with screws of the following specifications.
Place the camera on a flat surface. If you have to place the camera on an inclined surface, make sure that the inclination is less than ±15 degrees to guarantee pan/tilt performance, and take measures to prevent it from falling.
4 = 4.3 - 5 mm 4 = 0.17 - 0.20 inches

Installation of the camera using the tripod screws and screw holes should not be done for installation on a ceiling or a shelf, etc., in a high position.
Using the ceiling bracket, wire rope, and screws, you can utilize existing junction boxes, etc., to attach the camera to the ceiling. When you install the unit, always install it on a level ceiling. If you have to install it on a sloping or uneven ceiling, make sure that the place where you install it is within ±15 degrees of the horizontal.

2 Attach the wire rope to the junction box in the ceiling. Use a screw hole and a screw (not supplied) in the junction box to attach the wire rope.

Before installation After deciding the direction in which the camera will shoot, make the required holes for the junction box, and connecting cables.
The connecting cables cannot be passed through ceiling bracket (A). A hole for the wiring is required in the ceiling at the back of the unit where it is attached to the ceiling.
Hole for connecting cable
1 Set the IMAGE FLIP switch on the rear panel to ON.
Ceiling · Installation and Connection

3 Attach the ceiling bracket (B) to the junction box on the ceiling. Align the holes in the bracket with those in the junction box, and use appropriate screws (not supplied). There are elongated holes for the screws along the rounded edges of the ceiling bracket (B). Later, the front of the camera will be positioned along this edge. Face the camera to the front, adjust the aim, and attach it securely.
4 Attach the ceiling bracket (A) to the bottom of the camera using the 3 screws (M 3 × 8) supplied. Align the screw holes on the bottom of the camera with those in the ceiling bracket, and attach the bracket to the camera.


Attach the wire rope at the same time. M 3 × 8 (supplied)
Tighten the screws a bit at a time in the numbered order shown in the illustration. Attach the wire rope using the screw designated as number 3 above. After all of the screws are inserted and temporarily tightened properly, securely tighten each one in turn.
For assembly, use only the screws supplied with the unit. Using other screws may damage the unit.

5 Insert the protrusions raised on the ceiling bracket (A) into the spaces prepared in the ceiling bracket (B), and temporarily attach them by pushing the ceiling bracket (A) to the rear.
6 While pushing up on the front part of the camera, attach it using the three screws provided (M 3 × 8), starting with the screw at position 1.


7 Connect the cables to the connectors on the rear of the camera.
5-2 If the wire rope cannot be attached to the junction box, attach to the position on the ceiling bracket (B) in the illustration.
Take the proper steps to ensure that the load of the cables connected does not cause problems.
Installation and Connection

Connections
1 Remove the three screws used to attach the camera in step 6 of “Installation.”
2 While pushing the entire camera up towards the ceiling, move the camera to the front. The hooks will disengage, and you can remove the camera.
Use the AC power adaptor and AC power cord to connect the camera to an AC outlet.

Attach the camera using 3 M3 fixing screw holes located on the bottom of the camera. Attach the camera to a fitting with a flat surface using M3 screws with the following specifications.
4 = 3 – 5 mm 4 = 1/8 – 7/32 inches
M3 screw

To obtain a cable, consult your Sony dealer. For detailed information on how to connect the camera and the VISCA command list, refer to the Technical Manual of the camera. For details on obtaining a Technical Manual, consult your Sony dealer.


RS-422 to RS-232C converter (not supplied)


Connecting a video monitor or VTR equipped with a composite or S video input connector
Video monitor or VTR, etc.
It takes about 7 to 16 seconds to display the image.

The following messages and indications may appear for this camera. Perform the following as necessary.
Lamp Meaning and solution
The STANDBY lamp and POWER lamp are lit.
Set BOTTOM switch (5) to ON.
Message Meaning and solution
PRESET n:OK (“n” is a preset position number between 1 and 6)
This message appears for about 3 seconds when you store camera settings to POSITION 1 to 6.
RESET n:OK (“n” is a reset position number between 1 and 6)
This message appears for about 3 seconds when you reset camera settings stored in POSITION 1 to 6.
ONE PUSH WB:OP During the white balance adjustment in the ONE PUSH white balance mode, this message blinks on the screen.
ONE PUSH WB:OK When the white balance adjustment has been done correctly in the ONE PUSH white balance mode, this message is lit on the screen.
ONE PUSH WB:NG When the white balance adjustment has failed in the ONE PUSH white balance mode, this message blinks on the screen.
B Appendix · Appendix

Before bringing in your camera for service, check the following as a guide to troubleshooting the problem. If the problem cannot be corrected, consult your Sony dealer.
The picture is not displayed on the video monitor connected to the camera.
The video cable is not connected properly.
Check the connection between the camera and video monitor.
The VISCA control is not available with a computer connected to the camera.
The computer is not correctly connected to the camera.
Make sure the connection between the computer and camera is made correctly.
Check that the baud rate setting (9,600 bps or 38,400 bps) is properly made with the BOTTOM switch on the bottom of the camera (page 37).
The camera cannot be operated at all.
- Stop power to the DC 12 V connector. After a few moments, apply power again.
Symptom Cause Remedy

S VIDEO output (Y/C VIDEO
Internal synchronization Image device EVI-D80N/EVI-D80P: 1/4 type
JEITA type4 (DC 12 V)
Input voltage 12 V DC (10.8 to 13.2 V DC) Current consumption
(optical), 12× (digital) f = 4.1 – 73.8 mm, F1.4 – F3.0 Horizontal angle: 2.8 (TELE end)
EVI-D80N/EVI-D80P: 0.5 A max.
to 48.0 degrees (WIDE end) EVI-D90N/EVI-D90P: 28×
max. (at 12 V DC) Operating temperature
(optical), 12× (digital) f = 3.5 – 98.0 mm, F1.35 – F3.7 Horizontal angle: 2.1 (TELE end)
0 ºC to 40 ºC (32 ºF to 104 ºF) Storage temperature
–20 ºC to +60 ºC (–4 ºF to 140 ºF) Dimensions Video camera: 145 × 164 ×
to 55.8 degrees (WIDE end) Minimum object distance
164 mm (5 1/32 × 6 15/32 × 6 15/32 inches) (w/h/d, excluding protruding parts) Mass Video camera: EVI-D80N/EVI-D80P:
(WIDE end) to 800 mm (31 1/2 inches) (TELE end) 290 mm (11 27/64 inches) (Default) EVI-D90N/P: 10 mm (0.4 inches)
1440 g (3 lb 2 3/4 oz) EVI-D90N/EVI-D90P:
(WIDE end) to 1500 mm (59 1/16 inches) (TELE end) 300 mm (11 13/16 inches) (Default) Minimum illumination
1460 g (3 lb 3 1/2 oz) Installation angle
Less than ±15 degrees to the
equal to 0.4 lux (F1.4) with 50 IRE EVI-D90N/EVI-D90P: less or
Ceiling bracket (A) (1) Ceiling bracket (B) (1) Wire rope (1) Screw M 3 × 8 (8) VISCA RS-422 connector plug (1) Operating Instructions (1)
equal to 0.65 lux (F1.35) with 50 IRE Shutter speed 1 to 10,000 sec. Video S/N More or equal to 50 dB Pan/tilt action Horizontal: ±170 degrees
Design and specifications are subject to change without notice.
Maximum tilting speed: 90 degrees/sec.
COMPOSITE(VBS VIDEO
Appendix · horizontal surface · Video output

Note Always verify that the unit is operating properly before use. SONY WILL NOT BE LIABLE FOR DAMAGES OF ANY KIND INCLUDING, BUT NOT LIMITED TO, COMPENSATION OR REIMBURSEMENT ON ACCOUNT OF THE LOSS OF PRESENT OR PROSPECTIVE PROFITS DUE TO FAILURE OF THIS UNIT, EITHER DURING THE WARRANTY PERIOD OR AFTER EXPIRATION OF THE WARRANTY, OR FOR ANY OTHER REASON WHATSOEVER.






Using the VISCA RS-422 connector pin assignments
VISCA IN connector (mini-DIN 8-pin, female)
1 2 3 4 5
6 7 8 9
Pin No. Function
Pin No. Function
1 TXD IN+
2 DSR IN
2 TXD IN–
3 TXD IN
3 RXD IN+
4 GND
4 RXD IN–
5 RXD IN
5 GND
6 GND
6 TXD OUT+
7 IR OUT*
7 TXD OUT–
8 RXD OUT+
* The IR OUT function of pins 7 is selectable with the BOTTOM switch on the bottom of the camera.
VISCA OUT connector (mini DIN 8- pin, female)
Pin No. Function
2 DSR OUT
3 TXD OUT
4 GND
5 RXD OUT
6 GND
50 Specifications
8 Not used · 7 No connection · 8 No connection

1 Insert a wire (AW G Nos. 28 to 18) into the desired wire opening on the supplied VISCA RS-422 connector plug, and tighten the screw for that wire using a flat-head screwdriver.

2 Insert the VISCA RS-422 connector plug into the VISCA RS-422 connector on the rear of the camera.

1 2 3 4 5 6 7 8 9
Wire · Appendix · Flat-head screwdriver