EN
Sony logo
Official user manual

Sony D80P

51 pages·3 MB·Camcorder·PDF·ENDEFRITNL
Sony D80P
Table of Contents 23 sections Getting Started · Precautions · Phenomena Specific to CCD Image Sensors · Overview · … ShowHide
Page 1 of the Sony D80P user manual — 31 Table of Contents
Page 1 · click to enlarge
Page 1

Table of Contents

Getting Started

Precautions 32 Phenomena Specific to CCD Image Sensors 33

Overview

Features 34 Supplied Accessories 34 Location and Functions of Parts and Controls 35

Camera 35

Installation and Connection

Installing the Camera 38

Installing the Camera on a

Desk 38 Attaching the Camera to a

Tripod 38 Installing the unit on the

ceiling 38 Installing the Camera Using the M3

Fixing Screw Holes 42 Connections 42

Connecting to an AC Outlet 42 Connecting a Computer 43 Connecting a video monitor or VTR

equipped with a composite or S video input connector 44

Appendix

Message List 45 Troubleshooting 46 Specifications 47

Using the VISCA RS-422 connector

pin assignments 50

31 Table of Contents

Page 2 of the Sony D80P user manual — 32 Precautions
Page 2 · click to enlarge
Page 2

maintenance. If abnormal noise occurs, consult your Sony dealer.

Precautions

  • Operating or storage location Operating or storing the camera in the following locations may cause damage to the camera:
  • Extremely hot or cold places (Operating temperature: 0 °C to 40 °C [32 °F to 104 °F])
  • Exposed in direct sunlight for a long time, or close to heating equipment (e.g., near heaters)
  • Close to sources of strong magnetism
  • Close to sources of powerful electromagnetic radiation, such as radios or TV transmitters
  • Locations subject to vibration or shock

Ventilation To prevent heat buildup, do not block air circulation around the camera.

Transportation When transporting the camera, repack it as originally packed at the factory or in materials equal in quality.

  • Cleaning the main unit
  • When the body of the camera is dirty, clean it with a soft cloth that is soaked with a diluted neutral detergent and tightly wrung. Then finish with a dry cloth.
  • Do not use any type of solvents, which may damage the finish.
  • When you use a chemical cloth, follow its instructions.
  • Do not sprinkle volatile matter such as pesticide over your camera nor allow rubber or vinyl to come in contact with the camera for a long period of time. Doing so may damage the finish.

Maintenance The camera mechanism may cause abnormal noise due to wear and lubrication loss after a long period of use. To maintain optimum performance, we recommend periodical

32 Precautions

B Getting Started

Page 3 of the Sony D80P user manual — 33 Phenomena Specific to CCD Image Sensors
Page 3 · click to enlarge
Page 3

Phenomena Specific to CCD Image Sensors

The following phenomena that may appear in images are specific to CCD (Charge Coupled Device) image sensors. They do not indicate malfunctions.

White flecks Although the CCD image sensors are produced with high-precision technologies, fine white flecks may be generated on the screen in rare cases, caused by cosmic rays, etc. This is related to the principle of CCD image sensors and is not a malfunction.

  • White flecks tend to be seen particularly in the following cases:
  • during operation at a high environmental temperature
  • when you have raised the gain (sensitivity)

This phenomena may be improved by turning the camera off and then on again.

Aliasing When fine patterns, stripes, or lines are shot, they may appear jagged or flicker.

33 Phenomena Specific to CCD Image Sensors

Getting Started

Page 4 of the Sony D80P user manual — 34 Features / Supplied Accessories
Page 4 · click to enlarge
Page 4

Features

Supplied Accessories

  • An EX-view HAD™ CCD features 380,000 (NTSC) or 440,000(PAL) effective picture elements and highsensitivity shooting. The minimum illumination required is 0.7 lx (1/60 sec. (NTSC), 1/50 sec. (PAL), ICR OFF). (EVI-D90N/D90P)
  • A CCD features 380,000 (NTSC) or 440,000(PAL) effective picture elements and high-sensitivity shooting. The minimum illumination required is 0.4 lx (1/60 sec. (NTSC), 1/50 sec. (PAL)). (EVI-D80N/D80P)
  • The EVI-D90N/D90P are equipped with a bright zoom lens with 28× optical zoom and F1.35 aperture.
  • The EVI-D80N/D80P are equipped with a bright zoom lens with 18× optical zoom.
  • A newly-developed Processor provides high resolution images.
  • By adopting its wide and dynamic range functions, you can see the optimised shooting image which incorporates bright and dark subjects at the same time (EVI-D90N/D90P).
  • 3D Low-noise images can be obtained even in low-light environments using the Noise Reduction function.
  • Adopts the industry standard RS-232C interface of VISCA camera protocol in external communication. It is possible to operate from long distances by using both RS-232C and RS-422.
  • You can install the camera on ceilings due to the functions of high-speed and wide range pan/tilt action and vertical image flip.
  • You can store up to 6 kinds of camera direction and camera status into the camera.

When you unpack, check that all the supplied accessories are included.

Ceiling bracket (A) (1)

Ceiling bracket (B) (1)

34 Features / Supplied Accessories

B Overview · Camera (1)

Page 5 of the Sony D80P user manual — 35 Location and Functions of Parts and Controls
Page 5 · click to enlarge
Page 5

Location and Functions of Parts and Controls

Sony D80P — Location and Functions of Parts and Controls diagram (page 5)
Fig. 1 · Location and Functions of Parts and Controls
Sony D80P — Location and Functions of Parts and Controls diagram (page 5)
Fig. 2 · Location and Functions of Parts and Controls

Screw +M 3×8 (8)

Sony D80P — Location and Functions of Parts and Controls diagram (page 5)
Fig. 3 · Location and Functions of Parts and Controls

VISCA RS-422 connector plug (1)

Sony D80P — Location and Functions of Parts and Controls diagram (page 5)
Fig. 4 · Location and Functions of Parts and Controls
EVI-D80N/D80P18× magnification optical zoom lens EVI-D90N/D90P : 28× magnification optical zoom lens

Lights when the camera is turned on. It takes about 7 to 16 seconds to display the image after the lamp lights.

Lights when the camera is set to standby mode.

35 Location and Functions of Parts and Controls

Show 6 more labels / short text on this page
Wire rope (1) · Operating Instructions (1) · A Lens · B Remote sensors · C POWER lamp · D STANDBY lamp
Page 6 of the Sony D80P user manual — 36 Location and Functions of Parts and Controls
Page 6 · click to enlarge
Page 6

H VISCA RS-422 connector

To communicate via RS-422, use this connector. Use the supplied VISCA RS-422 connector plug.

Sony D80P — Location and Functions of Parts and Controls diagram (page 6)
Fig. 5 · Location and Functions of Parts and Controls

J S VIDEO(output) connector

K VISCA IN connector

Connect to a computer via an RS-232C interface. When you connect multiple cameras, connect it to the VISCA OUT connector of the previous camera in the daisy chain connection.

L VISCA OUT connector

When you connect multiple cameras, connect it to the VISCA IN connector of the next camera in the daisy chain connection.

M DC 12 V connector

Use only the polarity plug (standard JEITA/type 4).

F IMAGE FLIP switch

Flips the image upside down. Normally set this to OFF when you use the camera. When the camera is attached to the ceiling, set this to ON. Before you set the IMAGE FLIP switch, turn off the unit (or set to standby mode) and then, turn the power on by connecting the power adaptor, by VISCA control or the remote commander. When you switch this, the preset setting is returned to the initial setting. It takes about 7 to 16 seconds for the image displayed to respond to the setting change.

Polarity of the plug

G IR SELECT switch

Select the camera number when you operate multiple cameras with the same remote commander.

36 Location and Functions of Parts and Controls

Rear · I VIDEO(output) connector · E Remote sensors

Page 7 of the Sony D80P user manual — 37 Location and Functions of Parts and Controls
Page 7 · click to enlarge
Page 7

Setting of the BOTTOM switches

1 2 3 4 5

A D70 mode switch

Set to ON to use the VISCA command for EVI-D70/D70P.

B IR OUT switch

Set to ON to enable output of the receiver signals, which are transmitted from the infrared remote commander via the VISCA IN connector (page 50), or set it to OFF to disable the output.

C RS-232C/RS-422 select switch

Set to ON to operate colour video camera using the VISCA command via the RS-422 interface. To change the mode, turn off the camera (not including standby mode) first, set the switch and then turn on the camera again. Mode switching is not possible while the camera is turned on.

N Tripod screw hole

Used for RS-232C and RS-422 switching, 9,600 bps and 38,400 bps baud rate selection, D70 mode switching and IR signal output setting. For detailed information, refer to the Technical Manual of the camera.

D Baud rate select switch

Set to ON for 38,400 bps or OFF for 9,600 bps. To change the mode, turn off the camera (not including standby mode) first, set the switch and then turn on the camera again. The mode cannot be switched while the camera is turned on.

P Ceiling bracket mounting screw

holes

E Switch 5 (Not used)

Be sure to set this switch to OFF.

37 Location and Functions of Parts and Controls

Bottom · Overview · O BOTTOM switches

Page 8 of the Sony D80P user manual — 38 Installing the Camera
Page 8 · click to enlarge
Page 8

B Installation and Connection

Installing the Camera

Attaching the Camera to a Tripod

Attach a tripod to the screw hole used for attaching a tripod on the bottom of the camera. The tripod must be set up on a flat surface and its screws tightened firmly by hand. Use a tripod with screws of the following specifications.

Installing the Camera on a Desk

Place the camera on a flat surface. If you have to place the camera on an inclined surface, make sure that the inclination is less than ±15 degrees to guarantee pan/tilt performance, and take measures to prevent it from falling.

4 = 4.3 - 5 mm 4 = 0.17 - 0.20 inches

Sony D80P — Installing the Camera on a Desk diagram (page 8)
Fig. 6 · Installing the Camera on a Desk

Installation of the camera using the tripod screws and screw holes should not be done for installation on a ceiling or a shelf, etc., in a high position.

  • Do not grasp the camera head when carrying the camera.
  • Do not turn the camera head by hand. Doing so may result in a camera malfunction.
  • If you turn the camera head by hand without DC 12 V connection, the lamps on the front may light. This is not a malfunction.

Installing the unit on the ceiling

Using the ceiling bracket, wire rope, and screws, you can utilize existing junction boxes, etc., to attach the camera to the ceiling. When you install the unit, always install it on a level ceiling. If you have to install it on a sloping or uneven ceiling, make sure that the place where you install it is within ±15 degrees of the horizontal.

CAUTION

  • Entrust installation to an experienced contractor or installer when installing the unit on ceilings or other high locations.
  • When installing the unit in a high location, be sure that the location and installation components (excluding the supplied accessories) are strong enough to withstand at least 20 kg of weight, and install the unit securely. If the components are not strong enough, the unit may fall and cause serious injury.

38 Installing the Camera

Page 9 of the Sony D80P user manual — 39 Installing the Camera
Page 9 · click to enlarge
Page 9

2 Attach the wire rope to the junction box in the ceiling. Use a screw hole and a screw (not supplied) in the junction box to attach the wire rope.

  • Always install the supplied wire rope to prevent the unit from falling.
  • If you install the unit in a high location, check periodically, at least once a year, to ensure that the connection has not loosened. If conditions warrant, make this periodic check more frequently.
Sony D80P — Installation and Connection diagram (page 9)
Fig. 7 · Installation and Connection

Before installation After deciding the direction in which the camera will shoot, make the required holes for the junction box, and connecting cables.

The connecting cables cannot be passed through ceiling bracket (A). A hole for the wiring is required in the ceiling at the back of the unit where it is attached to the ceiling.

Installation

Hole for connecting cable

1 Set the IMAGE FLIP switch on the rear panel to ON.

  • Make sure that the BOTTOM switch is set to the correct position. See “Setting of the BOTTOM switches” (page 37).
  • If you set the IMAGE FLIP switch to ON after turning on the power, the image will not be flipped. Turn the power off once, then on again, and the image will be flipped. It takes about 7 to 16 seconds to display the image.
  • When you toggle the IMAGE FLIP switch, the pre-set settings will all be returned to the initial settings.

39 Installing the Camera

Ceiling · Installation and Connection

Page 10 of the Sony D80P user manual — 40 Installing the Camera
Page 10 · click to enlarge
Page 10

3 Attach the ceiling bracket (B) to the junction box on the ceiling. Align the holes in the bracket with those in the junction box, and use appropriate screws (not supplied). There are elongated holes for the screws along the rounded edges of the ceiling bracket (B). Later, the front of the camera will be positioned along this edge. Face the camera to the front, adjust the aim, and attach it securely.

4 Attach the ceiling bracket (A) to the bottom of the camera using the 3 screws (M 3 × 8) supplied. Align the screw holes on the bottom of the camera with those in the ceiling bracket, and attach the bracket to the camera.

Sony D80P — Installation and Connection diagram (page 10)
Fig. 8 · Installation and Connection
Sony D80P — Installation and Connection diagram (page 10)
Fig. 9 · Installation and Connection

Attach the wire rope at the same time. M 3 × 8 (supplied)

Tighten the screws a bit at a time in the numbered order shown in the illustration. Attach the wire rope using the screw designated as number 3 above. After all of the screws are inserted and temporarily tightened properly, securely tighten each one in turn.

For assembly, use only the screws supplied with the unit. Using other screws may damage the unit.

40 Installing the Camera

Page 11 of the Sony D80P user manual — 41 Installing the Camera
Page 11 · click to enlarge
Page 11

5 Insert the protrusions raised on the ceiling bracket (A) into the spaces prepared in the ceiling bracket (B), and temporarily attach them by pushing the ceiling bracket (A) to the rear.

6 While pushing up on the front part of the camera, attach it using the three screws provided (M 3 × 8), starting with the screw at position 1.

Sony D80P — Installation and Connection diagram (page 11)
Fig. 10 · Installation and Connection
Sony D80P — Installation and Connection diagram (page 11)
Fig. 11 · Installation and Connection

7 Connect the cables to the connectors on the rear of the camera.

5-2 If the wire rope cannot be attached to the junction box, attach to the position on the ceiling bracket (B) in the illustration.

Take the proper steps to ensure that the load of the cables connected does not cause problems.

41 Installing the Camera

Installation and Connection

Page 12 of the Sony D80P user manual — 42 Connections
Page 12 · click to enlarge
Page 12

Removing the camera

Connections

1 Remove the three screws used to attach the camera in step 6 of “Installation.”

Connecting to an AC Outlet

2 While pushing the entire camera up towards the ceiling, move the camera to the front. The hooks will disengage, and you can remove the camera.

Use the AC power adaptor and AC power cord to connect the camera to an AC outlet.

Sony D80P — Connecting to an AC Outlet diagram (page 12)
Fig. 12 · Connecting to an AC Outlet

Installing the Camera Using the M3 Fixing Screw Holes

Attach the camera using 3 M3 fixing screw holes located on the bottom of the camera. Attach the camera to a fitting with a flat surface using M3 screws with the following specifications.

DC 12 V

4 = 3 – 5 mm 4 = 1/8 – 7/32 inches

42 Connections

M3 screw

Page 13 of the Sony D80P user manual — 43 Connections
Page 13 · click to enlarge
Page 13

To obtain a cable, consult your Sony dealer. For detailed information on how to connect the camera and the VISCA command list, refer to the Technical Manual of the camera. For details on obtaining a Technical Manual, consult your Sony dealer.

Connecting a Computer

Sony D80P — Connecting a Computer diagram (page 13)
Fig. 13 · Connecting a Computer
Sony D80P — Connecting a Computer diagram (page 13)
Fig. 14 · Connecting a Computer

RS-422 to RS-232C converter (not supplied)

  • When you connect a computer to the camera using the VISCA cable (RS-232C cross cable), you can control the camera from a computer.
  • In the case of VISCA RS-232C connection, make sure that the BOTTOM switch is set to RS-232C (page 37).
  • It is not possible to connect both VISCA RS-232C and VISCA RS-422 simultaneously.
  • Do not mix VISCA RS-232C (cross) and VISCA RS-422 cables. Using these cables at the same time may result in malfunction.
  • Make up the cable using the supplied VISCA RS-422 connector plug. See “Using the VISCA RS-422 connector pin assignments” (page 50).
  • In the case of VISCA RS-232C connection, make sure that the BOTTOM switch is set to RS-232C (page 37).
  • It is not possible to connect both VISCA RS-232C and VISCA RS-422 simultaneously.

43 Connections

Show 7 more labels / short text on this page
RS-232C Connections · RS-422 Connections · Installation and Connection · VISCA RS-422 cable · to RS-232C input · Computer · Computer
Page 14 of the Sony D80P user manual — 44 Connections
Page 14 · click to enlarge
Page 14
  • Do not mix VISCA RS-232C (cross) and VISCA RS-422 cables. Using these cables at the same time may result in malfunction.
Sony D80P — Connecting a video monitor or VTR equipped with a composite or S video input connector diagram (page 14)
Fig. 15 · Connecting a video monitor or VTR equipped with a co…

Connecting a video monitor or VTR equipped with a composite or S video input connector

Video monitor or VTR, etc.

It takes about 7 to 16 seconds to display the image.

44 Connections

Page 15 of the Sony D80P user manual — 45 Message List
Page 15 · click to enlarge
Page 15

Message List

The following messages and indications may appear for this camera. Perform the following as necessary.

Lamp display

Lamp Meaning and solution

The STANDBY lamp and POWER lamp are lit.

Set BOTTOM switch (5) to ON.

Screen display

Message Meaning and solution

PRESET n:OK (“n” is a preset position number between 1 and 6)

This message appears for about 3 seconds when you store camera settings to POSITION 1 to 6.

RESET n:OK (“n” is a reset position number between 1 and 6)

This message appears for about 3 seconds when you reset camera settings stored in POSITION 1 to 6.

ONE PUSH WB:OP During the white balance adjustment in the ONE PUSH white balance mode, this message blinks on the screen.

ONE PUSH WB:OK When the white balance adjustment has been done correctly in the ONE PUSH white balance mode, this message is lit on the screen.

ONE PUSH WB:NG When the white balance adjustment has failed in the ONE PUSH white balance mode, this message blinks on the screen.

45 Message List

B Appendix · Appendix

Page 16 of the Sony D80P user manual — 46 Troubleshooting
Page 16 · click to enlarge
Page 16

Troubleshooting

Before bringing in your camera for service, check the following as a guide to troubleshooting the problem. If the problem cannot be corrected, consult your Sony dealer.

The picture is not displayed on the video monitor connected to the camera.

The video cable is not connected properly.

Check the connection between the camera and video monitor.

The VISCA control is not available with a computer connected to the camera.

The computer is not correctly connected to the camera.

Make sure the connection between the computer and camera is made correctly.

Check that the baud rate setting (9,600 bps or 38,400 bps) is properly made with the BOTTOM switch on the bottom of the camera (page 37).

The camera cannot be operated at all.

- Stop power to the DC 12 V connector. After a few moments, apply power again.

46 Troubleshooting

Symptom Cause Remedy

Page 17 of the Sony D80P user manual — 47 Specifications
Page 17 · click to enlarge
Page 17

S VIDEO output (Y/C VIDEO

Specifications

OUT)Mini DIN 4-pin type Control input/output
VISCA INMini DIN 8-pin type,

System

RS-232C VISCA OUTMini DIN 8-pin
Video signal EVI-D80N/ EVI-D90NNTSC EVI-D80P/ EVI-D90P: PAL Synchronization
type, RS-232C VISCA RS-4229-pin Power connector

Internal synchronization Image device EVI-D80N/EVI-D80P: 1/4 type

JEITA type4 (DC 12 V)

CCD EVI-D90N/EVI-D90P1/4 type

General

EXview HAD CCD Lens EVI-D80N/EVI-D80P18×

Input voltage 12 V DC (10.8 to 13.2 V DC) Current consumption

(optical), 12× (digital) f = 4.1 – 73.8 mm, F1.4 – F3.0 Horizontal angle: 2.8 (TELE end)

EVI-D80N/EVI-D80P: 0.5 A max.

(at 12 V DC) EVI-D90N/EVI-D90P0.67 A

to 48.0 degrees (WIDE end) EVI-D90N/EVI-D90P: 28×

max. (at 12 V DC) Operating temperature

(optical), 12× (digital) f = 3.5 – 98.0 mm, F1.35 – F3.7 Horizontal angle: 2.1 (TELE end)

0 ºC to 40 ºC (32 ºF to 104 ºF) Storage temperature

–20 ºC to +60 ºC (–4 ºF to 140 ºF) Dimensions Video camera: 145 × 164 ×

to 55.8 degrees (WIDE end) Minimum object distance

164 mm (5 1/32 × 6 15/32 × 6 15/32 inches) (w/h/d, excluding protruding parts) Mass Video camera: EVI-D80N/EVI-D80P:

EVI-D80N/P10 mm (0.4 inches)

(WIDE end) to 800 mm (31 1/2 inches) (TELE end) 290 mm (11 27/64 inches) (Default) EVI-D90N/P: 10 mm (0.4 inches)

1440 g (3 lb 2 3/4 oz) EVI-D90N/EVI-D90P:

(WIDE end) to 1500 mm (59 1/16 inches) (TELE end) 300 mm (11 13/16 inches) (Default) Minimum illumination

1460 g (3 lb 3 1/2 oz) Installation angle

Less than ±15 degrees to the

EVI-D80N/EVI-D80Pless or

equal to 0.4 lux (F1.4) with 50 IRE EVI-D90N/EVI-D90P: less or

Supplied accessories

Ceiling bracket (A) (1) Ceiling bracket (B) (1) Wire rope (1) Screw M 3 × 8 (8) VISCA RS-422 connector plug (1) Operating Instructions (1)

equal to 0.65 lux (F1.35) with 50 IRE Shutter speed 1 to 10,000 sec. Video S/N More or equal to 50 dB Pan/tilt action Horizontal: ±170 degrees

Maximum panning speed100 degrees/sec. Vertical: +90, –20degrees

Design and specifications are subject to change without notice.

Maximum tilting speed: 90 degrees/sec.

Input/output connectors

COMPOSITE(VBS VIDEO

OUT)RCA phono jack (1), 75 ohm unbalanced,1Vpp (at 75-ohm termination) Synchronization: negative

47 Specifications

Appendix · horizontal surface · Video output

Page 18 of the Sony D80P user manual — 48 Specifications
Page 18 · click to enlarge
Page 18

Note Always verify that the unit is operating properly before use. SONY WILL NOT BE LIABLE FOR DAMAGES OF ANY KIND INCLUDING, BUT NOT LIMITED TO, COMPENSATION OR REIMBURSEMENT ON ACCOUNT OF THE LOSS OF PRESENT OR PROSPECTIVE PROFITS DUE TO FAILURE OF THIS UNIT, EITHER DURING THE WARRANTY PERIOD OR AFTER EXPIRATION OF THE WARRANTY, OR FOR ANY OTHER REASON WHATSOEVER.

48 Specifications

Page 19 of the Sony D80P user manual — 49 Specifications
Page 19 · click to enlarge
Page 19

Dimensions

Sony D80P — Dimensions diagram (page 19)
Fig. 16 · Dimensions
Sony D80P — Dimensions diagram (page 19)
Fig. 17 · Dimensions
Sony D80P — Dimensions diagram (page 19)
Fig. 18 · Dimensions
Sony D80P — Dimensions diagram (page 19)
Fig. 19 · Dimensions
Unitmm (inches)

49 Specifications

Show 5 more labels / short text on this page
Top Back · Front · Side · Appendix · Bottom
Page 20 of the Sony D80P user manual — 1 DTR OUT
Page 20 · click to enlarge
Page 20

Pin assignments

Using the VISCA RS-422 connector pin assignments

VISCA IN connector (mini-DIN 8-pin, female)

The VISCA RS-422 connector pin assignments

1 2 3 4 5

6 7 8 9

VISCA RS-422

Pin No. Function

Pin No. Function

1 DTR IN

1 TXD IN+

2 DSR IN

2 TXD IN–

3 TXD IN

3 RXD IN+

4 GND

4 RXD IN–

5 RXD IN

5 GND

6 GND

6 TXD OUT+

7 IR OUT*

7 TXD OUT–

8 RXD OUT+

* The IR OUT function of pins 7 is selectable with the BOTTOM switch on the bottom of the camera.

9 RXD OUT–

VISCA OUT connector (mini DIN 8- pin, female)

Pin No. Function

1 DTR OUT

2 DSR OUT

3 TXD OUT

4 GND

5 RXD OUT

6 GND

50 Specifications

8 Not used · 7 No connection · 8 No connection

Page 21 of the Sony D80P user manual — 51 Specifications
Page 21 · click to enlarge
Page 21

Using the VISCA RS-422 connector plug

1 Insert a wire (AW G Nos. 28 to 18) into the desired wire opening on the supplied VISCA RS-422 connector plug, and tighten the screw for that wire using a flat-head screwdriver.

Sony D80P — Using the VISCA RS-422 connector plug diagram (page 21)
Fig. 20 · Using the VISCA RS-422 connector plug

2 Insert the VISCA RS-422 connector plug into the VISCA RS-422 connector on the rear of the camera.

Sony D80P — Using the VISCA RS-422 connector plug diagram (page 21)
Fig. 21 · Using the VISCA RS-422 connector plug

1 2 3 4 5 6 7 8 9

  • In order to stabilize the voltage level of the signal, connect both ends to GND.
  • Do not make a VISCA RS-232C connection when there is already an existing VISCA RS-422 connection.

51 Specifications

Wire · Appendix · Flat-head screwdriver

Ask about the Sony D80P

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Sony D80P

Be the first to ask — other owners or our team will answer.

Original document

Sony D80P manual PDF

51 pages·3 MB·Camcorder·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…