T able of contents Impor tant - Please read first Rectangular or ov al pools Round pools Installation P ool Side Alarm T ransmitter Assemb ly Batter y Installation Low Batter y Indication T urn The Un.
IMPOR T ANT - Please read fir st THIS PR ODUCT DOES NO T REPLA CE THE NEED FOR ADUL T SUPER VISION OF ALL PERSONS IN THE POOL AREA. IT I S NO T A LIFE SA VING DEVICE. I T I S AN AID TO A MUL TI LEVEL PROGRAM OF POOL SAFETY INCLUDING ADUL T SUPER VISION, KNO WLEDGE OF CPR AND SWIMMING INSTRUCTION FOR ALL PERSONS USING THE POOL.
ALARM If the water returning from the filter is positioned at 6 oícloc k and the flow is countercloc k- wise, the best location to put the alarm is between 8 oícloc k to 9 oícloc k position. On the other hand, if the flow is clockwise , the alar m should be placed between 3 oícloc k to 4 oícloc k position.
Installation 1. T ak e to p seat cap of pool off and remov e t h e screws holding one end of the top seat 2. Lift up one en d of the top s e at of pool 3. Hang the sensor tube onto the guide rail. Ba c k of the sensor unit should rest against the inside of pool wall.
Sensitivity Adjust Loosen the two scre ws on the bottom of the sensor . Mov e t h e plastic piece with the pointer pointed to ìHî i f you want higher sensitivity or to ìL î if you want low er sensitivity .
Using t h e base as a template, drill 3 holes of 1/8" diameter on the top seat. Mount the unit onto the top seat as shown (right). Battery Installation The pool side alarm is designed to be powered by a standard 9V alkaline batter y . After installing batter y , pr ess the TEST b utton located at the front on the control unit.
T urn the unit ON Press the green ON button and the unit will sound one shor t beep to indicate it is on. The alar m siren will sound when the sensor picks up any water wave motion. Therefore you should wait a few minutes for the water wave to settle down before turning on the unit.
Alarm unit function test Fill a 5 Gal pail 1/3 full with water and drop the pail from a height of a fe w inches from the surface of w ater . The wa ve created should activ ate the alar m. I f t h is test is unsucessful, adjust the sensitivity (ref er to Sensitivity Adjust section).
RF (radio frequency) signal link testing This unit provides a con venient RF link test, to ensure good RF transmission without setting off the alar m. Hit the T E ST button and hold f or a couple of seconds. The unit will sound one beep or fiv e consecutive beeps .
T ransmitter Channel A/B select The pool side alar m RF (radio frequency) signal can be transmitted from the transmitter to the receiv er inside the house by t w o diff erent channels (A or B).
Remote receiver Place the remote receiv er inside your house b ut close to the pool side alarm unit and a t a s traight line of sight. D O N O T place the unit near large metal objects or large motors , such as a r efr iger ator , or w ashing machine .
Back up po wer The receiver unit is designed to use a regular alkaline 9V batter y as bac k up power source. T o in stall this back up batter y , r e move t h e 4 screws and open the ba ttery door .
- A B GN PW O/P A/C adapter power jac k Channel A/B select switc h Commmon Normal Close Normal Open + K-1 Relay Ext. Connection Receiver Circuit Board The ter minal b lock signal s witching is controlled by m i croprocessor . For current switching, it is recommended to connect a K-1 type rela y (not included) to the ter minal b lock as sho wn.
T rouble Shooting Q . The alarm unit gives frequent false alarms Check the sensitivity setting. The sensitivity may be set too high. The sensor can detect any water disturbance including the flow from the filter pump . Pl ace the alar m unit aw a y fr om the retur n, or put a deflector cap on the sensor cage .
Q . The receiver cannot receive RF alarm signal. When the blue RESET b utton on the front is pressed, the unit is disab led for 10 seconds . Du ring this 10 seconds, it will not receiv e any RF signal. This allows y ou enough time to go to the poolside to turn off or reset the poolside alar m.
An important point after buying a device SmartPool Inc PE13 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought SmartPool Inc PE13 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data SmartPool Inc PE13 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, SmartPool Inc PE13 you will learn all the available features of the product, as well as information on its operation. The information that you get SmartPool Inc PE13 will certainly help you make a decision on the purchase.
If you already are a holder of SmartPool Inc PE13, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime SmartPool Inc PE13.
However, one of the most important roles played by the user manual is to help in solving problems with SmartPool Inc PE13. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device SmartPool Inc PE13 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center