Sizing Guide st andb y GENERATORS.
Generator Sizing Guide General Information Import ant Notice This booklet is designed t o familiarize estimators and installers with proper sizing guidelines f or residential and commer cial generators.
Generator Sizing Guide T able 1 – Motor Load Ref erence AC and Heat Pum ps Running Load Starting Load Running Amps at Amps at Amps at Starting LR Amps LR Amps LR Amps Description Hp kW 240V 1ø 208V.
Generator Sizing Guide T able 2 – Non-Motor Load Ref erence General Residential Running Load Amps at Amps at Description kW 120V 1ø 240V 1ø Electric heat per 1000 ft. 2 12 n/a 50 Heat pump elements per 1000 ft. 2 7 n/a 29 Dr yer 5.5 n/a 23 Hot tub 5 n/a 21 Range oven 5 n/a 21 Hot water 4.
Generator Sizing Guide T able 3 – Surge Capability Siemens Liquid Cooled Generators Operating at <3600 RPM Rated Output Surge Capability Surge Capability (Running Amps) LR Amps at 15% V oltage Di.
Generator Sizing Guide T able 4 – F uel Pipe Sizing Natural Gas Pipe Size (in.) kW 0.75" 1" 1.25" 1.5" 2" 2.5" 3" 7 55 200 820 10 20 85 370 800 13 10 50 245 545 16.
Generator Sizing Guide T able 5 – LP V apor (LPV) T ank Sizing V apor Withdraw al T ank Capacity T ank Capacity Length Diameter Ov erall Ht. Minimum T emp T ank Capacity T otal (Gal.
Generator Sizing Guide UPS Generator Compatibility Passiv e (also referenced as standby or off-line) and Line-Interactive These technologies ar e most common for personal w orkstations and point of sale applications.
Generator Sizing Guide Onsite Estimating Sheet Contractor _____________________________________________ Email _________________________________________________ Phone _________________________ F ax ___.
Generator Sizing Guide Onsite Estimating Sheet Generator Sizing Instructions: There is no t a single correct sizing solution. The instructions below identify multiple methods that, when mix ed with good judgment, should result in a moderat ely sized generator .
Generator Sizing Guide Onsite Estimating Sheet Contractor _____________________________________________ Email _________________________________________________ Phone _________________________ F ax ___.
Generator Sizing Guide Onsite Estimating Sheet Generator Sizing Instructions: There is no t a single correct sizing solution. The instructions below identify multiple methods that, when mix ed with good judgment, should result in a moderat ely sized generator .
Generator Sizing Guide Onsite Estimating Sheet Contractor _____________________________________________ Email _________________________________________________ Phone _________________________ F ax ___.
Generator Sizing Guide Onsite Estimating Sheet Generator Sizing Instructions: There is no t a single correct sizing solution. The instructions below identify multiple methods that, when mix ed with good judgment, should result in a moderat ely sized generator .
Notes.
Siemens Energy & Automation, Inc. 3333 Old Milton Parkwa y Alphare tta, GA 30005 1-800-964-4114 infosea@siemens.com www .sea.siemens.com/generators RPSA-GENSZ-0506 New 3M0506B&A Printed in USA ©2006 Siemens Energy & Automation, Inc. All Rights Reserved Siemens is a register ed trademark of Siemens AG.
An important point after buying a device Siemens Standby Generators (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Siemens Standby Generators yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Siemens Standby Generators - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Siemens Standby Generators you will learn all the available features of the product, as well as information on its operation. The information that you get Siemens Standby Generators will certainly help you make a decision on the purchase.
If you already are a holder of Siemens Standby Generators, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Siemens Standby Generators.
However, one of the most important roles played by the user manual is to help in solving problems with Siemens Standby Generators. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Siemens Standby Generators along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center