Edition April 1999 Fibre Channel to SCSI Router PSFR-CP41 Installing, Star ting Up and Maintaini ng.
This manual is printed on paper treated with chlorine-free bleach. Comments … Suggestions … Corrections … The User Documentation Department would lik e to know your opinion on this manual. Y our f eedback helps us t o optimize our documentation t o suit your i ndividual needs.
U42093-J-Z716-1-74 Operating Manual Intr oduci ng the PSFR-CP41 The PSFR-CP41 provides connecti vity between a Fibre Channel Switched F abric (FC- SW) or Arbitrated Loop (FC-AL) and one Fast/Wi de/Ultra SCSI bus.
Operating Manual U42093-J-Z716- 1-74 Features Introducing the PSFR-CP41 F ront panel of the PSFR-CP41 Bac k panel of the PSFR-CP41 Features Fibre Channel Featur es – Fibre Channel initiator and target modes – Single 1.
U42093-J-Z716-1-74 Operating Manual Introducing the PSFR-CP41 Features SCSI Bus Features – SCSI initiator and target modes – Single auto-negotiating SCSI b us (Narrow , Wide, F ast, Ultra) – Ult.
Operating Manual U42093-J-Z716- 1-74 Specifications Introducing the PSFR-CP41 Specificat ions Physical Specifications – Internal power supply with po wer switch and detac hable pow er c ord – Fibr.
U42093-J-Z716-1-74 Operating Manual Introducing the PSFR-CP41 PSFR-CP41 Ben efits PSFR-CP41 Benefi ts P oint-to-P oint Single initi ator to single target.
Operating Manual U42093-J-Z716- 1-74 PSFR-CP41 Ben efits Introducing the PSFR-CP41 Single Initiator Single initiator to m ultiple targets Multi-Initiator Multiple ini tiators to single or multipl e ta.
U42093-J-Z716-1-74 Operating Manual Introducing the PSFR-CP41 PSFR-CP41 Ben efits A vailability With two units , dual loop attachment provides redundancy and no si ngle point of f ailure. Connectivity SCSI de vices ma y be attached to Fibre Channel storage netw or ks to share data and increase address space .
Operating Manual U42093-J-Z716- 1-74 How the PSFR-CP41 W orks Introducing the PSFR-CP41 Ho w the PSFR- CP41 W orks The PSFR-CP41 acts as a pass-though de vice that translates Fibre Channel FCP to and from a SCSI bus so de vices on these tw o types of media can communicate with eac h other .
U42093-J-Z716-1-74 Operating Manual Introducing the PSFR-CP41 Operating as Both a SCSI and Fibre Channel D e Operating as Both a SCSI and Fibre Channel Devi ce The router is both a SCSI and Fibre Channel de vice operating on a SCSI bus and Fibre Channel network simultaneously .
Operating Manual U42093-J-Z716- 1-74 Processing SCSI Inf ormation Introducing the PSFR-CP41 Pr ocessing SCSI Info rmation The f ollowing describes ho w the r outer processes SCSI inf or mation: 1. A FC host issues a command. The FC host encapsul ates the command in the FCP protocol and sends the pac ket to the PSFR-CP41.
U42093-J-Z716-1-74 Operating Manual Introducing the PSFR-CP41 Processing Fibre Channel Informatio n Pr ocessing Fibre Channel Information The PSFR-CP41 processes inf or mation from the SCSI b us host by requesting operations of targets on a F ibre Channel Storage Area Network (SAN).
U42093-J-Z716-1-74 Operating Manual Installin g the PSFR-CP41 This chapter describes how to setup and install the PSFR-CP41. This includes unpack ing the PSFR-CP41 for t he first time, f actors to consider when installing the PSFR-CP41, either desktop or rac k installation instructions , and connecting to diff erent types of devi ces.
Operating Manual U42093-J-Z716- 1-74 Mounting the PS FR-CP41 in a Rack Installing the PSFR-CP41 Mounting the PSFR-CP41 in a Rack F ollow the directions belo w to mount the PSFR-CP41 in a standard rac k.
U42093-J-Z716-1-74 Operating Manual Installing the PSFR-CP41 Mounting the PSFR-CP41 in a Rack Installation Procedure Place the PSFR-CP41 so the rear f an vent and the front intak e vents remain clear of obstructions to ensure proper airflow . 1. Remov e the router from the protective bag.
Operating Manual U42093-J-Z716- 1-74 Mounting the PS FR-CP41 in a Rack Installing the PSFR-CP41 T o reduce injur y or equipment damage , the mounting brack ets must be le vel. If the brac kets are not le vel, the PSFR-CP41 cannot be instal led corre ctly .
U42093-J-Z716-1-74 Operating Manual Installing the PSFR-CP41 Mounting the PSFR-CP41 in a Rack If y ou are mounting the PSFR-CP41 in the front of the r ack with the connectors f acing the back or in the bac k of the rack with the connecto rs facing the front, attach the mounting brac kets as sho wn i n Fig.
Operating Manual U42093-J-Z716- 1-74 Mounting the PS FR-CP41 in a Rack Installing the PSFR-CP41 Mounting at bac k of rack 7. Attach each brac ket to a rear mounting rail , using one screw on each side.
U42093-J-Z716-1-74 Operating Manual Installing the PSFR-CP41 Mounting the PSFR-CP41 in a Rack 8. Attach the slide rails to the PSFR-CP41 using two s c re w s on each side . Slide the unit bac k into the rack and push in on the front tabs until the rails snap into place .
Operating Manual U42093-J-Z716- 1-74 Mounting the PS FR-CP41 in a Rack Installing the PSFR-CP41 Interfaces and Connections There are f our different types of ph ysical interf aces to the PSFR-CP41: Fibre Channel SCSI RS-232 (Serial por t) Ethernet The RS-232 and Ethernet por ts are used pr imarily f or PSFR-CP41 configu- ration and management.
U42093-J-Z716-1-74 Operating Manual Installing the PSFR-CP41 Mounting the PSFR-CP41 in a Rack Fibre Channel Connection Bef ore connecting the PSFR-CP41 to other Fibre Channel de vices , it is impor tant to understand the configuration requirements of the en vironment to which it will be connected.
Operating Manual U42093-J-Z716- 1-74 Mounting the PS FR-CP41 in a Rack Installing the PSFR-CP41 Fibre Channel connection SCSI Connection The PSFR-CP41 suppor ts F ast/Ultra Wide SCSI. The PSFR-CP41 is factory configured to suppor t Diff er ential SCSI bus .
U42093-J-Z716-1-74 Operating Manual Installing the PSFR-CP41 Mounting the PSFR-CP41 in a Rack To connect the PSFR-CP41 to the SCSI b us: 1. P ower off y our SCSI devices. 2. Connect a SCSI cab le to one of the SCSI connectors on the back of the router .
Operating Manual U42093-J-Z716- 1-74 Mounting the PS FR-CP41 in a Rack Installing the PSFR-CP41 SCSI terminator 6. P ower on y our SCSI devi ces. 7. After all the SCSI de vices hav e completed their individual POSTs , power on the PSFR-CP41.
U42093-J-Z716-1-74 Operating Manual Installing the PSFR-CP41 Mounting the PSFR-CP41 in a Rack PSFR-CP41 Ethernet por t Serial P ort Connection The RJ11 connector on the rear panel of the PSFR-CP41 pro.
Operating Manual U42093-J-Z716- 1-74 Mounting the PS FR-CP41 in a Rack Installing the PSFR-CP41 PSFR-CP41 Serial por t A utobaud Feature The autobaud f eature automatically configures the baud rate on the PSFR- CP41.
U42093-J-Z716-1-74 Operating Manual Installing the PSFR-CP41 Mounting the PSFR-CP41 in a Rack Connecting the Po wer Cord The pow er cord shipped with the PSFR-CP41 is a 120 V AC t hree-conductor pow er cord for use in the United States or Canada.
Operating Manual U42093-J-Z716- 1-74 Management Information Base (MIB) Installing the PSFR-CP41 Management Info rmation Base (MIB) A MIB (Management Inf or mation Base) is an element used in netw or k.
U42093-J-Z716-1-74 Operating Manual Installing the PSFR-CP41 Management Informat ion Base (MIB) MIB SCS I Inter face Info rmation The MIB gathers S CSI inf or mation for management pur poses.
U42093-J-Z716-1-74 Operating Manual Under standing the PSFR-CP41 Configurati on Of primar y impor tance in configuring the PSFR-CP41 is determining the mode of operation required. The unit c an be configured to suppor t Fibre Channel hosts communicating with S CSI targets, or SCSI hosts communicating wi th Fibre Channel targets.
Operating Manual U42093-J-Z716- 1-74 Understanding the PSFR-CP41 Configuration The fac tor y default configur ation of the unit allows such a configuration t o work without fur ther configur ation in most cases.
U42093-J-Z716-1-74 Operating Manual Understanding the PSFR-CP41 Configuration General Fibre Channel C onfig u General F ibre Chan nel Configuratio n On a Fibre Channel arbitrated loop , the PSFR-CP41 appears at a single Arbitrated Loop Ph ysical Address (AL_P A).
Operating Manual U42093-J-Z716- 1-74 General SCSI Con figuration Understanding the PSFR-CP41 Configuration General SCSI Configuration The PSFR-CP41 appears on the SCSI bus as a singl e i nitiator . The default initiator ID is 7, and can be set via c onfiguration to an y valid SCSI address.
U42093-J-Z716-1-74 Operating Manual Understanding the PSFR-CP41 Configuration Address Mappin g Address Mapping The PSFR-CP41 suppor ts three addressing methods for mapping SCSI targets to Fibre Channel Hosts: Inde xed Addressi ng – Allows y ou to edit and maintain a static address mapping tabl e.
Operating Manual U42093-J-Z716- 1-74 Indexed Ad dressing Understanding the PSFR-CP41 Configuration Inde xed Addressing tab le The Inde xed Addressing tab le has the str ucture sho wn in T able. The PSFR- CP41 will allo w up to 80 devic e entr ies to be mapped.
U42093-J-Z716-1-74 Operating Manual Understanding the PSFR-CP41 Configuration Auto Addressing A uto Addressing The A uto Addressing option is similar to Inde xed Addres sing, but wi th the distinction that the tab le used is created through SCSI dev ice discov er y upon pow er up or reset, and not otherwise retained.
U42093-J-Z716-1-74 Operating Manual Configuring the PSFR-CP41 The PSFR-CP41 uses a menu structure to configure the PSFR-CP41 through the serial and telnet interfac es. The currently selected menu and th e fir mware v er sion currently e xec uting will be displa yed.
Operating Manual U42093-J-Z716- 1-74 Operation Indicators Configuring the PSFR-CP41 Operation Indicator s The PSFR-CP41 router is equipped with rear panel LED indicators for monitoring ov erall router status. The LED functi onality is detailed below: PSFR -CP41 L ED’ s Po w e r This green indicator turns on when power is applied to the router .
U42093-J-Z716-1-74 Operating Manual Configuring the PSFR-CP41 Host Device Configuratio n Host Device Configurat ion The host system using a F ibre Channel Host Bus Adapter (HBA) will typic ally map Fibre Channel de vices into the e xisting device mapping scheme us ed by that operating s ystem.
Operating Manual U42093-J-Z716- 1-74 De vice Ma nage ment Configuring the PSFR-CP41 Devi ce Manag ement The PSFR-CP41 can be managed through the RS-232 por t, ov er Ethernet via T elnet Web-Browser , or via SNMP . FTP and TFTP are also suppor ted f or firmware downloads .
U42093-J-Z716-1-74 Operating Manual Configuring the PSFR-CP41 Communicatin g with the P SFR-CP41 Communicating with the PSFR-CP41 The PSFR-CP41 is designed to function directl y out of the shipping con tainer with no special configuration required.
Operating Manual U42093-J-Z716- 1-74 Sett ing Up Serial P or t Com mu nicatio ns Configuring the PSFR-CP41 Setting Up Serial P or t Communications Leav e the PSFR-CP41 turned off until you hav e set up serial por t communica- tions with y our host computer .
U42093-J-Z716-1-74 Operating Manual Configuring the PSFR-CP41 Power U p Menu Po w e r U p M e n u When y ou tur n the PSFR-CP41’ s po wer s witch, a series of messages similar to the f ollowing appear: If yo u do not see message s on your s creen, re-chec k your co m puter’ s serial port settings and p ress Enter fiv e or six tim es.
Operating Manual U42093-J-Z716- 1-74 P e rform Configuration Configuring the PSFR-CP41 P erform Configuration The configuration men u allows the administr ator to configure the v ar ious options on the PSFR-CP41. F or any configuration changes to tak e effe ct, you must reboot the PSFR-CP41.
U42093-J-Z716-1-74 Operating Manual Configuring the PSFR-CP41 Perform Conf iguration Fibre Channel Configuration This option allo ws for setting the Fibre Channel Address method, hard address v alue, and WWN ov errides.
Operating Manual U42093-J-Z716- 1-74 P e rform Configuration Configuring the PSFR-CP41 When mapping SCSI T arget ID’s f or SCSI host to Fibre Channel T arget capability , the user must first enab le the target ID before proceeding to modify the mapping tab le for that de vice.
U42093-J-Z716-1-74 Operating Manual Configuring the PSFR-CP41 Perform Conf iguration SCSI-to-Fibre Channel Mapping Configuration This option allows modific ation of the table mapping SCSI T arget:LUN va lues to Fibre Channel Node:LUN v alues. Configuration of these de vices is similar to that for inde xed addres sing, without the user assists.
Operating Manual U42093-J-Z716- 1-74 P e rform Configuration Configuring the PSFR-CP41 Sa ve Configuration This option sa ves the current configuration s tate in FLASH, and updates the sav ed previ ous configur ation state. Restore Last Saved Configuration This option restores the most recent previously sav ed c onfiguration.
U42093-J-Z716-1-74 Operating Manual Configuring the PSFR-CP41 Display POST Statu s Display POST S tatus This option displa ys the results of the most recent pow er on self test (POST).
Operating Manual U42093-J-Z716- 1-74 Reboot Configuring the PSFR-CP41 Reboot The reboot function restarts the P SFR-CP41. This will caus e s elected configu- ration options to tak e effect. This will result in all cu rrent operations bein g interrupted.
U42093-J-Z716-1-74 Operating Manual Configuring the PSFR-CP41 Down load F irmwa re The fol lowing figure shows what y ou might see on your terminal when you download a ne w revision of the firmware: Dowloading a ne w re vision of the firmware Crossroads Systems CP4100 Configuration Version: X.
Operating Manual U42093-J-Z716- 1-74 Conf iguring t he PSFR-C P41’ s Eth ernet P ort Configuring the PS F R-CP41 Configuring the PSFR-CP41’ s Ethernet P or t If you plan to use Ethernet to configure the PSFR-CP41, you m ust first set up serial communications with the PS F R-CP41 to configure the Ethernet por t’ s address.
U42093-J-Z716-1-74 Operating Manual Configuring the PSFR-CP41 SNMP Configuratio n SNMP Configu ration The SNMP Configuration menu all ows for v ar ious SNMP options to be configured. This includes T rap manager IP address, comm unity names, and T rap priority .
Operating Manual U42093-J-Z716- 1-74 SNMP Configuration with T raps Enabled Configuring the PSFR-CP41 SNMP Configurat ion with T raps Enable d GET and SET Comm unity Names The SNMP GET comm unity name is check ed for each GET request receiv ed by the PSFR-CP41.
U42093-J-Z716-1-74 Operating Manual T roub lesho oting V ar ious prob lems can arise when configuring and using the PSFR-CP41. This section is pro vided to help guide the user through some o f the basic methods of identifying f aults in the setup and configuration of the unit.
Operating Manual U42093-J-Z716- 1-74 Basic V erification Troubleshooting Basic V erification V e rify SCSI Bus Configuration Prob lems with SCSI bus configuration are common. Basic operation of the SCSI bus can be c hecked b y using the configuration menu to vie w attached SCSI de vices.
U42093-J-Z716-1-74 Operating Manual Troubleshooting Basic Verification V erify Fibre Channel Connection If SCSI de vices are recogniz ed on the SCSI b us, b ut do not appear to the Fibre Channel host, it may be that the Fibre Channel link is not establ ished.
Operating Manual U42093-J-Z716- 1-74 Basic V erification Troubleshooting V erify Addressing If working i n FC-to-SCSI target mode and us ing Index ed or SCC A ddr essing, tr y s wapping to A uto Addressing to see if this solv es the problem.
U42093-J-Z716-1-74 Operating Manual Troubleshooting Basic Verification Running Diagnostics F or fur ther diagnostic testing, a Diagnost i c Cab le Kit can be purchased.
U42093-J-Z716-1-74 Operating Manual Append ix A RJ-11 Serial and RJ-45 Ethernet Pin Assignments RJ-11 pin assignments RJ- 45 pin assignments Pin No. Function Pin 1 No Connect Pin 2 Ground Pin 3 T ransmit Data Pin 4 Receive Data Pin 5 RTS Pin 6 CTS Pin No.
U42093-J-Z716-1-74 Operating Manual Append ix B Addressing, Structures an d Operation Fibre Channel and SCSI systems emplo y different methods of addressi ng de vices. The inclusion of a br idge or router requires that a method of translating de vice IDs be implemented so that each SCSI de vice is mapped to the appro- priate Fibre Channel LUN.
Operating Manual U42093-J-Z716- 1-74 Addressing, Structures and Operation Appendix B SCC Logical Unit A ddr essing LUN structure Address Method definitions Bit Byte 7 6 5 4 32 10 n 1 0 T arget n+1 Bus.
U42093-J-Z716-1-74 Operating Manual Appendix B Addressing, Structures and Operation Arbitrated Loop Node number to ALP A lookup tab l e 0:0x01 21:0x2E 42:0x 52 63:0x74 84:0xA6 105:0xC9 1:0x02 22:0x31 .
Operating Manual U42093-J-Z716- 1-74 SCC Addressing Option Appendix B SCC Addressing Option When the PSFR-CP41 is configured to use SCC addressing, the unit is capab le of responding as a controller de vice to the FCP Initiator , or routing the FCP request to a specified B US:T ARGET:LUN triplet.
U42093-J-Z716-1-74 Operating Manual Appendix B Indexed Addressing Optio n I n d e x e dA d d r e s s i n gO p t i o n Inde xed Addressi ng allows f or host b us adapter drivers that only use P eripheral Dev ice addressing to access SCSI de vices attached to the PSFR-CP41 unit.
Operating Manual U42093-J-Z716- 1-74 A u to Assigned Addressing Option Appendix B A uto Assigned Addressing Opti on The A uto Assigned option is similar to the Inde x ed addressing, but with the distincti on that the table used is cr eated through SCSI de vice discov er y on power up or reset, and not otherwise retained.
U42093-J-Z716-1-74 Operating Manual Append ix C Refer en ce Sta nda rds Fibre Channel Ph ysical and Signaling Interf ace (FC-PH), ANSI X3T9.3/Project 755D/Re v .
U42093-J-Z716-1-74 Operating Manual Glossar y Adapter A printed circuit assembly that t ranslates data between the FC host processor’ s internal bus and a diff erent bus, such as SCSI.
Operating Manual U42093-J-Z716- 1-74 Gloss ary Clusters T wo or more computers sharing the same resources on a comm unication link. Device S e eF CD e v i c eo rS C S ID e v i c e . Differential An electrical signal configurati on using a pair of lines f or data trans fer .
U42093-J-Z716-1-74 Operating Manual Gloss ary FC See Fibre Channel. FC-AL See Fibre Channel - Arbitrated Loop . FC Adapter A printed circuit assembly that t ranslates data between the FC host processor’ s internal bus and the FC link. FC Device A de vice that uses Fibre Channel communications.
Operating Manual U42093-J-Z716- 1-74 Gloss ary Fibre Channel (FC) Logically , the Fibre Channel is a bidirectional, f ull-duplex, point-to-point, serial data channel structured for high perf orm ance data comm unication.
U42093-J-Z716-1-74 Operating Manual Gloss ary Indexed Ad dressing It allows f or gener ic Fibre Channel host b us adapters to access SCSI dev i ces attached to the PSFR-CP41 using a t able whic h i s inde x ed by sequential LUN v alues.
Operating Manual U42093-J-Z716- 1-74 Gloss ary Mapping T able A tabl e which is index ed by s equential LUN v alues, indicating selecte d BUS:T ARGET:LUN de v ices . It is used by the PSFR-CP41 to perf or m Fibre Channel-to-SCSI operatio ns by def ault.
U42093-J-Z716-1-74 Operating Manual Gloss ary Online F or the PSFR-CP41, online indicates that at least one adapter in the PSFR- CP41 is activ e and av ailable f or access. F or a SCSI adapter , online indicates the SCSI adapter is activ e and av ailabl e for access and input/output processing.
Operating Manual U42093-J-Z716- 1-74 Gloss ary SCC Ad d ressing SCSI-3 Controller Commands (SCC) addressi ng is used to address SCSI de vices attached to the PSFR-CP41 using the SCC logic al unit addressing method. In SCC addressing mode , the PSFR-CP41 will respond to FCP commands as in a S CC controller de vice.
U42093-J-Z716-1-74 Operating Manual Gloss ary SCSI Sta t us A menu used to sho w the numb er, and status , of SCSI devic es on the bus . Shor twave Lasers or LEDs that emit light with wa velengths around 780 nm or 850 nm. Shor t wa ve lasers are used f or FC links up to ~700 m.
Operating Manual U42093-J-Z716- 1-74 Gloss ary T opo logy The ph ysical or logical lay out of nodes on a network. FC topologies include point-to-point, FC-AL, and F abric. The PSFR-CP41 suppor ts all topologies . A status type in the FC Status Menu sho wing the type of FC topology being used.
U42093-J-Z716-1-74 Operating Manual En vironmental p rotection En vironmentally friendly product design and development This product has been desi gned in accordance with the Siemens standard “environmental ly fr iendly product design and de velopment”.
Operating Manual U42093-J-Z716- 1-74 Environmental protection Fur ther information on en vironmental protection The Siemens AG representative f or environmental protection wil l be pleased to ans wer any fur ther questions y ou may ha ve concerning environmental protection.
Comments on Fibre Channel to SCSI Router PSFR-CP41 Installing, Star ting Up and Maintaining Comments Sugges tions Correc tions Submitted by U42093 -J-Z716-1- 74 Siemen s AG Informat ion and Communic ation Product s Comput er Syste ms User Do cumentat ion UNIX 33094 P ade rborn German y Fax: (++ 49) 52 51 8 -1 52 48 e-mail: DO Cetc@pdb.
An important point after buying a device Siemens PSFR-CP41 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Siemens PSFR-CP41 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Siemens PSFR-CP41 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Siemens PSFR-CP41 you will learn all the available features of the product, as well as information on its operation. The information that you get Siemens PSFR-CP41 will certainly help you make a decision on the purchase.
If you already are a holder of Siemens PSFR-CP41, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Siemens PSFR-CP41.
However, one of the most important roles played by the user manual is to help in solving problems with Siemens PSFR-CP41. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Siemens PSFR-CP41 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center