Instruction/ maintenance manual of the product EXP-1 Shure
Go to page of 16
7552 - 10 th Ave. N.E. Calgary Alberta, Canada T2E 8W1 Ph: 403.258.3100 email:info@guardiantel ecom.com www.guardiantel ecom.com Industrial Communications Worldwide Page/T alk Explosion Proof W all S t ations Models ExP-1 and ExP-5 Installation & Operation P005223 Rev.
Guardian Telecom Inc. Installation and Operation Page/Talk Indoor Housing Page 2 Table of Contents Package Contents .................................................................................2 Overview ...........................................
Guardian Telecom Inc. Installation and Operation Page/Talk Indoor Housing Page 3 Overview ExP-1/-5 Explosion Proof Page/Talk Wall Stations Guardian's Page/Talk Systems provide reliable and easy to use paging and communication within industrial environments such as plants, mills an d factories.
Guardian Telecom Inc. Installation and Operation Page/Talk Indoor Housing Page 4 FOR SPEAKER CONNECTION CORD CONNECTOR HANDSET/HEAD SET 1" NPT ENTRANC E Figure 1 - ExP-1/-5 Features 10.
Guardian Telecom Inc. Installation and Operation Page/Talk Indoor Housing Page 5 Figure 3 - Mounting 7.25 [184mm ] ENTRANCE 14.67 [ 3 73mm ] .4 Ø SIDE TONE ADJUST TRANSMITTER LEVEL ADJUST SPEAKER MUT.
Guardian Telecom Inc. Installation and Operation Page/Talk Indoor Housing Page 6 Installing the ExP-1/-5 WARNING - high voltages are present in this equipment when it is connected to the power source. • Ensure that the location is non-hazardous before proceeding with any installation or electrical wiring.
Guardian Telecom Inc. Installation and Operation Page/Talk Indoor Housing Page 7 Assignment Designation Description Jacket Color Stripe Color Wire Gauge System Power J4A/J5A HOT Black 14 AWG J4A/J5A C.
Guardian Telecom Inc. Installation and Operation Page/Talk Indoor Housing Page 8 Group Muting In order to avoid acoustical feedback it may be desirable in certain circumstances to mute speakers associated with adjoining stations when making a paging call.
Guardian Telecom Inc. Installation and Operation Page/Talk Indoor Housing Page 9 Ambient Noise Level Adjustment The Ambient Noise Sensor on Gua rdian ' s Page/ Talk stations automatically adjusts the volume of the associated loudspeaker up to 10dB, so that page s can be heard over the background noise.
Guardian Telecom Inc. Installation and Operation Page/Talk Indoor Housing Page 10 Troubleshooting Note: If access to the interior of the ExP-1/-5 is required refer to the appropriate section. See: Accessing the Interior of the ExP-1/-5 Station Is Dead But Associated Speaker Is Working • No repair possible, return station for repair.
Guardian Telecom Inc. Installation and Operation Page/Talk Indoor Housing Page 11 Engineering Specifications E LECTRICAL R EQUIREMENTS I NPUT V OLTAGE 20 - 26 / 90-140 / 200-260 VAC, 24 - 30VDC I NPUT F REQUENCY 50/60H Z I NPUT V OLTAGE /C URRENT /F USE 120VAC/0.
Guardian Telecom Inc. Installation and Operation Page/Talk Indoor Housing Page 12 Warranty Guardian Telecom warrants your product to be free of defects in material and workmanship for a period of one year. Guardian Telecom will repair or replace any defective unit that is under warranty free of charge.
Guardian Telecom Inc. Installation and Operation Page/Talk Indoor Housing Page 13 Guardian Product Return Guardian products have been quality tested and are in full working order when shipped from the factory, given the rugged nature of these products shipping is not expected to damage a unit.
Guardian Telecom Inc. Installation and Operation Page/Talk Indoor Housing Page 14 Page/Talk System Models and Options Indoor Handset Stations PTI-1 & PTI-5 P5550 Ambient noise sensor, single line .
Guardian Telecom Inc. Installation and Operation Page/Talk Indoor Housing Page 15 Typical Installation.
Guardian Telecom Inc. 7552 - 10th Street N.E. Calgary, Alberta, Canada T2E 8W1 Toll-free 1-800-363-8010 Ph. (403) 258-3100 Fax. (403) 253-4967 www.guardiantelecom.com E-mail: mailto:sales@guardiantelecom.com (Click to open message box) Industrial Communications Worldwide © Guardian Telecom Inc.
An important point after buying a device Shure EXP-1 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Shure EXP-1 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Shure EXP-1 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Shure EXP-1 you will learn all the available features of the product, as well as information on its operation. The information that you get Shure EXP-1 will certainly help you make a decision on the purchase.
If you already are a holder of Shure EXP-1, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Shure EXP-1.
However, one of the most important roles played by the user manual is to help in solving problems with Shure EXP-1. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Shure EXP-1 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center