Index Important Safeguards 2 General Information 2 Grounding Instructions 3 Operation/Accessories 3 Remove From Carton 4 Brush & Drive Block Installation .. 5 Adjustments 5 Controls 6 Guidelines For Operation 6 Cord Storage 7 Clean Up And Storage 7 Warranty Back Cover

We suggest you record the model, type and serial numbers below. They are located on the silver rating plate on your cleaner. For prompt and complete service information, always refer to these numbers when inquiring about service.
For location of nearest Eureka Warranty Station or service information call 1-800-800-8975. *En Mexico llame al 5670-6169.
Model & Type
Serial No.
It is also important to keep your receipt as proof of date of purchase.

When using an electrical appliance, basic precautions should always be followed, including the following:
READ ALL INSTRUCTIONS BEFORE USING THIS VACUUM CLEANER.
To reduce the risk of fire, electric shock, or injury:
Use the cleaner to pick up dirt and dust particles. Avoid picking up hard or sharp objects that could damage the vacuum cleaner.
The instructions in this booklet serve as a guide to routine maintenance. For additional service information, telephone our toll free number for the nearest Eureka Authorized Warranty Station. You should know the model, type and serial number or date code when you call:
Canada: 1-800-282-2886
If you prefer, you can write to The Eureka Company, Service Division, 807 North Main St., Bloomington, Illinois 61701, USA. In Canada, write to The Eureka Company, 866 Langs Drive, Cambridge, Ontario N3H 2N7. Refer to The Eureka Warranty for complete service information.
DO NOT OIL the motor or the brush drive. The motor and brush drive are permanently sealed and lubricated.

Grounding Instructions This appliance must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment- grounding conductor and grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
Your floor machine is packed complete and ready for use after you install a brush or drive block. (Brushes and pads are not provided with the unit but are available at an additional cost.)
Improper connection of an equipment-grounding conductor can result in risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the appliance. If it will not fit the outlet, have proper outlet installed by a qualified technician.
Your floor machine is designed to be used for many different floor care applications. Make sure you use the correct brush or pad for the type of job you want to perform. (Accessories are available from the dealer from whom the floor machine was purchased.)
This appliance is for use on a nominal 120 volt circuit and has a grounding plug that looks like the plug illustrated in Figure 1. A temporary adapter which looks like the adapter illustrated in Figure 2 may be used to connect this plug to a two-pole receptacle, as shown, if a properly grounded outlet is not available. The temporary adapter should be used only until a properly grounded outlet, Figure 1, can be installed by a qualified electrician. The green colored rigid ear, lug, or the like extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box cover. Whenever the adapter is used, it must be held in place by a metal screw.
When ordering brushes or drive blocks, refer to this chart and specify correct brush or block diameter when ordering.
For floor finishing machines rated 150-250 volts:
If the machine is provided with an attachment plug cap as shown in Fig. 3, it is intended for use on a 240 volt (nominal) circuit. No adapter is available for this application.
FIGURE 1
Grounding Tab Metal Screw Adapter
FIGURE 3
Plug Grounding Pin · Plug Grounding Pin











ADJUSTMENTS
DRIVE BELT ADJUSTMENT (Model 20” 1500 rpm 1.5 HP only)


To install a brush or pad driver, leave the handle in the upright position and tip the machine backwards so it rests on its wheels and upper handle section (Fig. 4). The brush and pad driver both attach in the same manner: align the cutouts on the inner ring of the brush or pad driver with the tabs on the inside of the ring of the drive hub (Fig. 5). Push the brush or pad driver firmly in position, then turn it counterclockwise until it locks into place.
To remove, turn the brush or pad driver clockwise until it stops, then lift it off. Note: Always remove the brush or pad driver when the machine is not in use.

The handle can be adjusted to any desired work position by simply pushing up on the handle lock (Fig. 7). Move the handle to the desired position, then firmly push down on the handle lock which will lock the handle in position.

PAD CENTERING LOCK (Model 20” 1500 rpm 1.5 HP only)
To install a pad, tip the machine backwards so it rests on the rear wheels and handle. After centering the pad on the pad holder, insert the Pad Centering Lock and twist it clockwise until it securely locks in place. To remove twist the lock counterclockwise.
Adjusting Bolts · Unlock · Lock

With the handle cam lock in the “up” position (unlocked), tighten the adjusting nuts until there is a slight drag when the handle is raised or lowered. The tube should be locked securely when the handle lock is pressed downward (Fig. 8).
To stop the machine, simply release the triggers. The safety switch lock will automatically return to the engaged position.

The model 20” 175/300 2-speed is a two-speed floor machine designed for dual operation, scrubbing or buffing. A toggle switch on the left side of the switch box selects the output speed, 175 rpm for scrubbing or 300 rpm for buffing. Do not operate this floor machine for buffing in low speed, it will not do an effective job and tends to overload the motor unnecessarily.
The ON/OFF switch is conveniently located in the form of dual triggers underneath the handle grips.
The operating handle must be lowered to the operating position before switching the machine ON. Place both hands firmly on the handle grips with your fingers around the power triggers. Do not apply pressure on the triggers before the safety switch lock is disengaged.
Disengage the safety switch lock by pushing it forward with one thumb. Then, while holding the safety switch lock in disengaged position, squeeze the power triggers toward the handle grips and return your thumb to the handle grip.
Push forward to disengage safety switch lock.

DO NOT LET THE MACHINE REST ON THE PAD OR BRUSH FOR AN EXTENDED PERIOD OF TIME. This may alter the shape of the pad or brush which may cause the machine to wobble.
Adjusting Nuts

CORD STORAGE When not in use, loosely wind the power cord around the cord storage hook on the handle shaft and both of the handle grips, as shown.

CLEAN UP AND STORAGE After being used, your floor machine can be wiped clean with a soft, damp cloth and should be stored in a clean, dry place.

Floor Machines / Air Movers
Your equipment which has been manufactured, tested and inspected in accordance with carefully specified engineering requirements is warranted to be free from defects in material and workmanship. This Limited Warranty is, however, subject to the following qualifications, conditions and limitations which are set forth to provide you and all users of the equipment with information concerning the duration, extent, availability and applicability of the Limited Warranty, the procedure to be taken to obtain its performance, and other information concerning the Limited Warranty policy.
The Limited Warranty is extended to the original end user as follows: Machines: 3 years parts replacement and 1 year service labor warranty. Replacement parts guaranteed for 90 days from date of installation against defects in material and workmanship.
This Limited Warranty will not cover damage attributable to the following:
(1) Improper, unreasonable or negligent use or abuse of the equipment. (2) Use of equipment with hot water or high temperature above 130 degrees Fahrenheit (Solution Tanks) (3) Abrasions or punctures of the equipment.
The start date of the Limited Warranty coverage shall be the purchase date of the original end user or six months from the date the machine was shipped from the Factory, whichever comes first.
PARTS OF EQUIPMENT NOT COVERED BY THE LIMITED WARRANTY Certain parts of equipment require replacement in the ordinary course of use due to normal wear by reason of their characteristics. Normal wear items such as cords, switches, bumpers, carbon brushes, handle grips, belts, bearings, etc. are excluded from the Limited Warranty.
EXCEPTIONS AND EXCLUSIONS FROM THE LIMITED WARRANTY This equipment is required to be used on electric current as indicated on the data plate. Otherwise damage, defects, malfunctions or other failure of the equipment arising from use on electric current not as indicated are excepted and excluded from this Limited Warranty. Defects, malfunctions, failure or damage of the equipment caused by improper, unreasonable or neglect use or abuse while in possession of the purchaser are likewise excluded from this warranty. If repair is done on your equipment by anyone other than those designated as an authorized Warranty Center, THE MANUFACTURER at its sole option, may determine that this warranty will not apply and the reimbursement for such repair will not be made.
PROCEDURE TO BE TAKEN TO OBTAIN PERFORMANCE OF LIMITED WARRANTY REPAIR To secure repair of the equipment or any warranted parts under this Limited Warranty, the following procedure should be taken. The inoperative equipment or warranted parts, together with satisfactory evidence of the purchase date, must be delivered, with shipping and delivery changes prepaid, to one of the following:
(1) the dealer from whom purchased; or (2) any authorized service station.
If you are unable to locate any of the foregoing, you may write or otherwise communicate to THE MANUFACTURER before repair service is performed by anyone else. In such event, THE MANUFACTURER will provide either the location of a closely available authorized distributor service department, authorized service station or other factory instructions. Upon compliance with the above procedure, all warranted defects will be repaired, at no additional charge or costs to the customer and the repaired product returned to the customer, with all shipping and delivery charges prepaid. In following the procedures set forth, PLEASE MAKE CERTAIN to state the model, type and serial number as shown on the data plate of the equipment.
REPLACEMENT In the event of a defect, malfunction or failure of your equipment or any warranted part to conform with this warranty, THE MANUFACTURER may, at its sole option and own expense, replace the equipment or any warranted part with another new identical or reasonably equivalent model or part in lieu of repairing the defect.
NO REFUND OF PURCHASE PRICE THE MANUFACTURER will not, as a matter of its Limited Warranty policy, refund the customer’s purchase price.
Be certain that the Warranty Station is “Eureka/Sanitaire Authorized.” For the location of the nearest Eureka/Sanitaire Authorized Station or for service information, see us at www.sanitairevac.com or telephone toll free: 1-800-800-8975.
©2003 White Consolidated, Ltd.
Part No. 73416 (09/03)
Printed in U.S.A.
Excludes Vacuums