EN
Rolls logo
Official user manual

Rolls PS16

2 pages·57 KB·Power Supply·PDF·ENDEFRITNLJA
Rolls PS16
Table of Contents 10 sections PS16 POWER CENTER · Personal Monitor · Power Supply Signal Distribution · - LINE INPUTS unbal balanced · … ShowHide
Page 1 of the Rolls PS16 user manual — Owners Manual
Page 1 · click to enlarge
Page 1

LIMITED WARRANTY This product is warranted to the original consumer purchaser to be free from defects in materials and workmanship under normal installation, use and service for a period of one (1) year from the date of purchase as shown on the purchaser’s receipt. The obligation of Rolls Corporation under this warranty shall be limited to repair or replacement (at our option), during the warranty period of any part which proves defective in material or workmanship under normal installation, use and service, provided the product is returned to Rolls Corpora- tion, TRANSPORTATION CHARGES PREPAID. Products returned to us or to an authorized Service Center must be accompanied by a copy of the purchase receipt. In the absence of such purchase receipt, the warranty period shall be one (1) year from the date of manufacture. This warranty shall be invalid if the product is damaged as a result of defacement, misuse, abuse, neglect, accident, destruction or alteration of the serial number, improper electrical voltages or currents, repair, alteration or maintenance by any person or party other than our own service facility or an authorized Service Center, or any use violative of instructions furnished by us. This one-year warranty is in lieu of all expressed warranties, obligations or liabilities. ANY IMPLIED WARRANTIES, OBLIGATIONS, OR LIABILITIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICU- LAR PURPOSE, SHALL BE LIMITED IN DURATION TO THE ONE YEAR DURATION OF THIS WRITTEN LIMITED WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. IN NO EVENT SHALL WE BE LIABLE FOR ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESSED OR IMPLIED, WHATSO- EVER. Some states do not allow the exclusion or limitation of special, incidental or consequential damages so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

PS16 POWER CENTER

Personal Monitor

Power Supply Signal Distribution

Rolls PS16 — PS16 POWER CENTER diagram (page 1)
Fig. 1
Rolls PS16 — PS16 POWER CENTER diagram (page 1)
Fig. 2

- LINE INPUTS unbal balanced

12VAC

+

PERSONAL MONITOR POWER CENTER

  • The PS16 supplies the DC power and distributes the Monitor signal to up to ten of the PM50s, the PM50sOB, and the PM350 units. This dramatically increases efficiency and eliminates the need for multiple wall-warts and adapter cables.
  • Supplies power for up to ten PM50s, PM50sOB, and PM350 units.
  • Directly supplies a monitor signal to the above listed units.
  • Unbalanced 1/4" and TRANS FORMER-balanced XLR inputs.

PS16 POWER CENTER

PS16

Rolls Corporation Salt Lake City, UT 6/02

www.rolls.com

OUT 1 OUT 2 OUT 3 OUT 4

READ THIS MANUAL FOR IMPORTANT OPERA- TION INSTRUCTION. TIP-RING-SLEEVE PLUGS ARE REQUIRED FOR THE OUTPUTS OF THIS UNIT.

Owners Manual

power status

Page 2 of the Rolls PS16 user manual — OUT 1 OUT 2 OUT 3 OUT 4
Page 2 · click to enlarge
Page 2

INTRODUCTION Thank you for your purchase of the PS16 Personal Monitor Power Center. The PS16 supplies the DC power and distributes the Monitor signal to up to ten of the PM50s, the PM50sOB, and the PM350 units. This dramati- cally increases efficiency and eliminates the need for multiple wall-warts and adapter cables.

  • CONNECTION / OPERATION
  • Connect the Send of the mixer to the appropriate Input of the PS16 (balanced or unbalanced).
  • Connect the PS12 adapter to the 12VAC input of the PS16. The Power/ Status LED should light. If not, immediately unplug the power as this indicates a short from the Ring of an Output jack to ground.
  • Connect the TIP-RING-SLEEVE STEREO cables from the PS16 Outputs to the PM series Monitor Inputs. Refer to the Personal Monitor unit owners manual for proper operation of that unit.

The power AND monitor signal are carried from each PS16 output using an ordinary 1/4" stereo cable to the Monitor input of the PM50s, sOB, and 350. Using stereo “Y” adapters, up to ten of the Personal Monitor Amplifi- ers may be daisy-chained.

FOR APPLICATION DIAGRAMS, VISIT OUR WEBSITE AT WWW.ROLLS.COM

SPECIFICATIONS Input Power: 12 VAC, 700 mA Output Power: 12 VDC on the Ring terminal of each OUT jack. Size: 3.125" x 3.125" x 1.25" Weight: 1 lb (.45 Kg)

SCHEMATIC

FEATURES - Supplies power for up to ten PM50s, PM50sOB, and PM350 units. - Directly supplies a monitor signal to four of the above units, indirectly (by using stereo “Y” adapters) will provide signal for up to ten units. - Unbalanced 1/4" and TRANSFORMER-balanced XLR inputs.

PHONE 1/4 J1 XLR JACK M T1 2 J11 3 XFMR AUDIO J2 LOW OUT PHONE 1/4 1 J2 PHONE 1/4 J3 HIGH OUT PHONE 1/4 J4 PHONE 1/4 U1 D4 2200UF 16V 7812 1 I O 3 PM SERIES OUTS 1N4001 C17 R1 C7 G D1 4.7K 1U 2 IN 9-15 VAC/VDC J10 2 1 DN 34001 D LD5 RR 3 1 1N4001 JAPDC D2 1N4001 ROLLS CORPORATION 5968 S 350 West MURRAY UT 84107 PS16 PM POWER CENTER Document Number: Rev: Ba PS16.SCH A Date: 22 MAY 2002 Sheet 1 of 1 ROLLS CORPORATION 5968 S 350 West MURRAY UT 84107 PS16 PM POWER CENTER BaDocument Number: PS16.SCHRev: A Date: 22 MAY 2002 Sheet 1 of 1

DESCRIPTION LINE INPUTS UNBALANCED: 1/4' Tip-Sleeve jack. Connects to a mixer's unbalanced Monitor or Auxiliary Send. BALANCED: Transformer isolated female XLR jack.Connects to a mixer's balanced Monitor or Auxiliary Send. 12VAC: Connects to the included Rolls PS12 power adapter.

Rolls PS16 — SCHEMATIC diagram (page 2)
Fig. 3

- LINE INPUTS unbal balanced

12VAC

PERSONAL MONITOR POWER CENTER

Rolls PS16 — 12VAC diagram (page 2)
Fig. 4

PS16

OUT 1 - 4: 1/4" Tip-Ring-Sleeve jacks. The Tip of the connector contains the audio signal, the Ring has the 12 volts DC required to operate the Personal Monitor devices, and the Sleeve con- nects to ground.

www.rolls.com

OUT 1 OUT 2 OUT 3 OUT 4

+ · power status

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Rolls PS16

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Rolls PS16

Be the first to ask — other owners or our team will answer.

Original document

Rolls PS16 manual PDF

2 pages·57 KB·Power Supply·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…