F33 Freestanding Gas Stove
Manual

PLEASE KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE
FOR YOUR SAFETY What to do if you smell gas: Do not try to light any appli- ance Do not touch any electri- cal switch: do not use any phone in your building. Immediately call your gas supplier from a neighbour's phone. Follow the gas sup- plier's instructions. If you cannot reach your gas supplier, call the fi re department.
These gas appliances have been tested in accordance with AS4553-2000, NZS 5262 and have been certifi ed by the Australian Gas Association for installation and opera- tion as described in these Installation and Operating Instructions.
FOR YOUR SAFETY Do not store or use gasoline or other fl am- mable vapours and liquids in the vicinity of this or any other appliance.
Installation and service must be performed by an authorized installer, service agency or the gas supplier.
Your unit should be serviced annually by an authorised service person.
918-532a · 01/11/07

Congratulations! You are the owner of a state-of-the-art Gas Stove by Fireplace Products International Ltd. The Regency® Gas Series of hand crafted appliances has been designed to provide you with all the warmth and charm of a woodstove, at the fl ick of a switch. The models F33-NG3 and F33-LPG3 have been approved by the Australian Gas Association for both safety and effi ciency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your F33-3 Freestanding Gas Stove.



This is a copy of the label that accompanies each Regency® F33-3 Freestanding Gas Stove. We have printed a copy of the contents here for your review.
DATA BADGE NOTE: Regency® units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.




INSTALLATION AND REPAIR SHOULD BE DONE BY AN AU- THORISED SERVICE PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY AN AUTHORISED SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, ETC. IT IS IMPERA- TIVE THAT CONTROL COMPARTMENTS, BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.
DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.
The F33-3 Freestanding Gas Stove must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. Consult the "authority having jurisdiction" to determine the need for a permit prior to starting the installation.
CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES, ESPECIALLY THE FIREPLACE GLASS, AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLI- ANCE.
CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE.
INFORMATION
Test the pilot. Must be as per diagram in the "Pilot Adjustment" section.
a. Optional Remote Wall Switch b. Optional Remote Control Installation c. Optioanl Wall Thermostat Installation
Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring correctly and operation fully explained to customer.
This includes: 1) Clocking the appliance to ensure the correct fi ring rate (rate noted on label) after burning appliance for 15 minutes.

The clearances listed below are MINIMUM distances. Measure the clearance to both the appliance and the chimney connector. The farthest distance is correct if the two clearances do not coincide. For example, if the appliance is set as indicated in one of the diagrams but the back wall is too close, move the stove until the correct clearance to the connector is obtained.
on pedestal.
This appliance may be installed only with the clearances as shown in the situations pictured. Do not combine clearances from one type of installation with another in order to achieve closer clearances. Use the minimum clearances shown in the diagrams.

F33-3 Clearance to Combustibles A Side Wall to Unit 250 mm B Back Wall to Unit 150 mm E Side Wall to Unit 38 mm
F33-3 Reference Dimensions C Back Wall to Flue Centerline 292 mm D Side Wall to Flue Centerline 559 mm F Side Wall to Flue Centerline 330 mm
Minimum ceiling height is 914 mm from top of unit.

Diagram 1

LEG AND BOTTOM SHIELD
Wiring Instructions
ASSEMBLY These instructions apply to the black, gold and nickel cast legs. It will be easier to attach the legs to the stove if it is tipped on its back (preferably on a soft surface to prevent scratching).




No electrical power supply is required for the gas control to operate. However, a 240V A.C. power supply is needed for the fan/blower operation.
Instructions This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a prop- erly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.
either a blocked chimney or backdraft condition where the chimney fl ow has reversed and will react by shutting off the gas supply.

The heater has a draft hood built into its back. It must not be altered or obstructed, and the unit must be installed so that the draft hood is in the same atmospheric pressure zone as the combustion air inlet to the burner.
FLUEING
100mm diameter fl ue is required in accordance with AS5601-2004, NZS 5261 or any relevant local building codes. For altitudes above 610m. we recommend that a minimum fl ue height of 3.6m is used.
This heater is a vented appliance and must be connected to a chim- ney/fl ue in accordance with installation codes.
For your safety this heater is equipped with a fl ue safety switch. This thermally actuated switch is located within the draft hood and will detect

The gas connection is a 1/2 inch BSP Male thread. The gas line can be rigid copper pipe. Pipe size to ensure correct operating pressure. For minimum and maximum supply pressure see the System Data table below.
Note: During any pressure testing of the gas supply piping system that exceeds test pressures of 3.45 kPa, this ap- pliance and its individual shut-off valve must be discon- nected from the piping system. If test pressures equal to or less than 3.45 kPa are used then this appliance can be isolated from the piping system by closing its individual manual shut-off valve, if fi tted, during the testing.

The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 3.45 kPa. Disconnect piping from valve at pressures over 3.45 kPa.

The manifold pressure is controlled by a regulator built into the gas control, and should be checked at the pressure test point.

LOG AND EMBER INSTALLATION
This heater must be properly connected to a fl ue system.
The gas log kit contains the following:
A “spillage” test must be made before the installed unit is left with the customer. Follow the procedure below:
a) Front Log b) Rear Log c) Small Cross Logs (2) d) Bag of embers e) Bag of rock wool 1) Remove the logs from the box and carefully unwrap them. The logs are fragile, handle with care. Do not force into position.
The smoke should be drawn into the draft hood. If the smoke is still not drawn into the draft hood, turn the unit off and check for the cause of the lack of draft and rectify before proceeding.
Note: If the fl ue is blocked or has a strong reverse fl ow, the thermally actuated safety switch mounted in the draft hood will automatically shut off the gas supply in less than 10 minutes. If the heater turns off because of this during the spillage test, check for the cause of the lack of draft and rectify before proceeding.
To reset the thermally actuated safety switch, let the unit cool for 10 minutes, then press the red reset button on the back of the switch. See Diagram.




Secure door in the closed position using the door securing bracket and the screw provided.

for safety.


7) Distribute the embers along the mesh ember tray, but do not cover the burner ports. (Burner ports are the little holes on the top of the burner tube.) Pull off ember size pieces from the rock wool. Gently place the pieces on top of the embers. See diagram 3. Do not put the rock wool directly on the burner. Close the door and turn the unit on as per lighting instructions. Watch the fl ame to see if it fl ows smoothly around from one end to the other. (Use Extreme Caution and ensure proper light off of burner.)

Attach spring handle by rotating counter clockwise onto rod. Ensure that the spring fi ts into the entire length of the rod.
Diagram 2

OPTIONAL WALL THERMOSTAT
SWITCH
A wall thermostat may be installed if desired.
Use a CSA, UCL or UL approved millivolt thermostat, 250-750 millivolt rated. A non-anticipator type thermostat must be used.
Use the Optional Regency® Remote Control Kit approved for this unit. Use of other systems may void your warranty.
The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate.
Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring correctly. This includes:

OPERATING INSTRUCTIONS
LIGHTING PROCEDURE
1) The FIRST FIRE in your stove is part of the paint curing process. To ensure that the paint is properly cured, it is recommended that you burn your fi replace for at least four (4) hours the fi rst time you use it with the fan on. When fi rst operated, the unit will release an odour caused by the curing of the paint and the burning off of any oils remaining from manufacturing. Smoke detectors in the house may go off at this time. Open a few windows to ventilate the room for a couple of hours. The glass panel may require cleaning.
DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS STILL HOT!
condensation and fog the glass. This condensation is normal and will disappear in a few minutes as the glass heats up.
DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE.

SHUTDOWN PROCEDURE
IT IS IN OPERATION

COPY OF THE LIGHTING PLATE INSTRUCTIONS
!" # !! $%&'%!$%!!# !( ) ! $* +,,-./0 (*12$!" ") "! ! ! $ */23./.4* "5*167/ ,772$ #+ 5 +1,6/8
!
A , ! ! #
" # $ $%&%'()* (+)!
(!! A , 2 ! ! , A ! ,
$ ! # ! , -* (./01%'') 0
2 2 " 2 (!! ! 3 2 2 ( " ! 4 / + , ( " 3 "
! "#! $ " %& ' %"! " (%" ) # & " % * #+ , # ( + )" " , ( % + -"+% $ ( ) && . $ % '!/ ." +# #& & # ! % + ( % "# % ##& ' ( # !
0 5 & ! ,
& ! ( " : ; ( " !! , ( , " , 9 + = / !
6 !(' 7 - , 89! ( ! 0 5 $ ! , ( 3 ! " # :
(' ;
(!! 4 <7 !
7 , !
. ! ,
· Gas Inlet · >?@2=;>

NORMAL OPERATING SOUNDS OF
During the annual service call, the burners should be removed from the burner tray and cleaned. Replace the embers and rock wool.
It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance. Listed below are some examples. All are normal operating sounds and should not be con- sidered as defects in your appliance.
Blower: Regency® gas appliances use high tech blowers to push heated air farther into the room. It is not unusual for the fan to make a "whirring" sound when ON. This sound will increase or decrease in volume depending on the setting of your fan switch.
Burner Tray: The burner tray is positioned directly under the burner tube(s) and logs and is made of a different gauge material from the rest of the fi rebox and body. Therefore, the varying thicknesses of steel will expand and contract at slightly different rates which can cause "ticking" and "crack- ing" sounds. You should also be aware that as there are temperature changes within the unit these sounds will likely re-occur. Again, this is normal for steel fi reboxes.
Blower Thermodisc: When this thermally activated switch turns ON it will create a small "clicking" sound. This is the switch contacts closing and is normal.
Pilot Flame: While the pilot fl ame is on it can make a very slight "whisper" sound.
Gas Control Valve: As the gas control valve turns ON and OFF, a dull clicking sound may be audible, this is normal operation of a gas regulator or valve.
CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE.
Unit Body/Firebox: Different types and thicknesses of steel will expand and contract at different rates resulting in some "cracking" and "ticking" sounds will be heard throughout the cycling process.
NEVER OPERATE THE APPLIANCE WITHOUT THE GLASS PROPERLY SECURED IN PLACE.
When cleaning the logs, use a soft clean brush as the logs are fragile and easily damaged.

GENERAL FLUE MAINTENANCE
Conduct an inspection of the fl ue system at least annually. Recom- mended areas to inspect are:
The unit should never be used with broken logs. Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs. The pilot light generates enough heat to burn someone. If for any reason a log should need replacement, use only Regency® replacement logs. The position of these logs must be as shown in the diagram under Log Installation.

The 24 carat gold plated fi nish on the door requires little maintenance, and need only be cleaned with a damp cloth. DO NOT use abrasive materials or chemical cleaners, as they may harm the fi nish and void the warranty. Clean any fi ngerprints off before turning the unit on.
Your F33-3 stove is supplied with high temperature, 5 mm Neoceram silica coated ceramic glass that will withstand the highest heat that your unit will produce. In the event that you break your glass by impact, purchase your replacement glass from an authorized Regency® dealer only, and follow our step-by-step instructions for replacement.

AERATION ADJUSTMENT
THERMOPILE/THERMOCOUPLE
REPLACEMENT
The burner aeration is factory set. Adjustment may be needed due to the local gas supply or altitude. As a general rule if the fl ame is too yellow open up the air shutter, if it is too blue close the air shutter.
NG 11 mm LPG wide open
Periodically check the pilot fl ames. Correct fl ame pattern has three strong blue fl ames: 1 fl owing around the thermopile, 1 around the thermocouple and 1 fl owing across the burner (it does not have to be touching the burner).


Top View of pilot fl ame
Incorrect fl ame pattern will have small, probably yellow fl ames, not coming into proper contact with the rear burner or thermopile or thermocouple.


Top View of pilot fl ame
Diagram 1 · Diagram 2

To remove valve from valve assembly, continue.

Orifice assembly mounting screws
INSTALLING VALVE ASSEMBLY

Front Cover Screws


For Leg Unit: Remove 7 screws, remove bottom access panel and replace fan assembly.

Diagram 1

TROUBLESHOOTING THE GAS CONTROL SYSTEM
Spark igniter will not light pilot.
Piezo wire loose Defective Piezo igniter. Piezo wire grounding out. Electrode is grounding out and/or wrong location.
Pilot will not stay lit after carefully fol- lowing lighting in- structions.
Defective thermopile. Defective thermocouple. Thermopile/thermocouple grounding out. Loose thermopile leads. TP-THTP on valve.
Defective automatic gas valve.
Pilot burning, no gas to burner. Valve knob is on. Wall switch is on.
Valve wire connections are loose. Valve wires are defective. Spill switch has not been reset (B-vent F/S). Spill switch is stuck in the open position. (B-vent INS - F/S).
Frequent pilot out- age problems.
Pilot fl ame may be too low or blowing high causing the pilot safety to drop out. Two way switch wires may be grounding out. Thermopile and/or thermo- couple may be grounding out.
ABNORMAL OPERATION If the main burner does not light but pilot stays on shut down heater and contact your dealer If excessive carbon on logs or glass contact your dealer

MAIN ASSEMBLY
Part # Description Part # Description
850-151 Large Door - Black 850-152 Large Door - Gold 850-153 Large Door - Nickel Accent 850-154 Large Door - Gold Accent
490-918 Packaged Fan Assembly 20) 910-155/P Fan/Blower Motor - 240V 21) 910-142 Thermodisc - Fan Auto ON/OFF 910-866 Wire Harness (stove connection end) 910-716 Wire Harness (fan connection end)
*Not available as a replacement part.

BURNER & LOG ASSEMBLY
Part # Description Part # Description
462-560/P Complete Valve Assy-SIT (NG) 462-561/P Complete Valve Assy-SIT (LPG) 63) 910-478 Valve SIT - NG/LPG 66) 910-034 Pilot Assembly 3-fl ame SIT NG 910-035 Pilot Assembly 3-fl ame SIT LPG 67) 904-604 Orifi ce #36 (NG) 904-390 Orifi ce #52 (LPG) 68) 948-294 Burner - NG 69) 948-279 Burner - LPG 70) * Complete Burner Tray Assy-SIT-NG 71) * Complete Burner Tray Assy-SIT-LPG 72) 490-023 Front Log Defl ector - NG/LPG
*Not available as a replacement part.


PEDESTAL & LEG ASSEMBLY
Part # Description Part # Description
Bottom Shield & Leg Option 100) 948-216 Logo Plate - Regency®
Pedestal Assembly 490-926 Complete Pedestal 100) 948-216 Logo Plate - Regency®
*Not available as a replacement part.




Regency® fi replace products are designed with reliability and simplic- ity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. Regency® Industries Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency® Product.
Exclusions: This limited Lifetime Warranty does not extend to or include paint, door or glass gasketing or trim. It does not cover installation and operational related problems such as over-fi ring, downdrafts or spillage caused by environmental conditions, nearby trees, buildings, hilltops, mountains, inadequate fl ueing or ventilation, excessive offsets, negative air pres- sures caused by insuffi cient make up air, mechanical systems such as furnaces, fans, clothes dryers etc. The warranty does not extend to any part or parts which show evidence of misuse or abuse, neglect, accident or lack of maintenance. Products made by other manufacturers and used in conjunction with the operation of this appliance without authorization from Regency®, may nullify your warranty on this product. Regency® Industries Ltd., shall in no event be liable for any special, indirect consequential damages of any nature whatsoever which are in excess of the original purchase price of the product. Any alteration to the unit which causes sooting or carboning that results in damage to the exterior facia is not the responsibility of Regency® Industries Ltd.
The Warranty: Lifetime Covered under the agreement are the following components: Combustion chamber, heat exchanger, burner tubes, logs, embers, glass (thermal breakage) and all gold plating (against defective manufacture). The above will be covered for parts and labour for the fi rst fi ve years and parts only thereafter. Electrical components such as blowers, switches, wiring, thermodiscs, remote control, thermopiles, thermocouples and gas valves are covered for one year from the date of purchase.
Conditions: All installations must be performed by an authorised gas fi tter and installed according to all applicable local and national codes. Also, all service work must be carried out by an authorised gas service person. It is the responsibility of the installer to ensure that the appli- ance is fi ring as per rating plate. Any part or parts of this unit which in our judgement show evidence of such defect will be repaired or replaced at Regency®'s option, through an accredited distributor or agent provided that the defective part be returned to the distributor or agent Transportation Prepaid, if requested. In areas where there is not an approved service agent or the closest approved service agent is situated more than twenty-fi ve (25) kilometres from the installation, Australian Heating Distributors are not obliged to arrange warranty repairs and travel and/or additional labour charges will apply.
General: It is essential that all submitted claims provide all of the necessary information including purchase date, serial #, type of unit and part or parts requested.
DISTRIBUTORS: Western Australia Eastern Australia AUSTRALIAN HEATING DISTRIBUTORS FIREPLACE PRODUCTS AUSTRALIA PTY. LTD. 31 CLUNE STREET 21-23 SOUTH LINK BLVD. BAYSWATER, WA 6053 DANDENONG, VIC 3175
INCORRECT INSTALLATION OR GAS PRESSURE SETTINGS ARE NOT COVERED BY WARRANTY
A SERVICE OR CALLOUT FEE WILL BE CHARGED IN THESE CIRCUMSTANCES.

PRINTED IN CANADA © Copyright 2007, FPI Fireplace Products International Ltd. All rights reserved.