Page 1 of the Quatech Serial Device Server (DSC-100) user manual — Two Channel RS-232 Asynchronous
Page 1 · click to enlarge
Page 1
Quatech Serial Device Server (DSC-100) diagram (page 1)
Fig. 1

DSC-100

Two Channel RS-232 Asynchronous

Communications Adapter

for PCI bus

User's Manual

QUATECH, INC. TEL(330) 434-3154 662 Wolf Ledges Parkway FAX: (330) 434-1409 Akron, Ohio 44311 http://www.quatech.com
Page 2 of the Quatech Serial Device Server (DSC-100) user manual — DATE OF PURCHASE:
Page 2 · click to enlarge
Page 2

WARRANTY INFORMATION

Quatech, Inc. warrants the DSC-100 to be free of defects for five (5) years from the date of purchase. Quatech, Inc. will repair or replace any board that fails to perform under normal operating conditions and in accordance with the procedures outlined in this document during the warranty period. Any damage that results from improper installation, operation, or general misuse voids all warranty rights.

Please complete the following information and retain for your records. Have this information available when requesting warranty service.

DATE OF PURCHASE:

MODEL NUMBER: DSC-100

PRODUCT DESCRIPTIONTwo Channel RS-232 Asynchronous PCI Bus Communications Adapter SERIAL NUMBER:
Page 3 of the Quatech Serial Device Server (DSC-100) user manual — NOTICE
Page 3 · click to enlarge
Page 3

(c) 1998 - 2001, Quatech, Inc.

NOTICE

The information contained in this document cannot be reproduced in any form without the written consent of Quatech, Inc. Likewise, any software programs that might accompany this document can be used only in accordance with any license agreement(s) between the purchaser and Quatech, Inc. Quatech Inc. reserves the right to change this documentation or the product to which it refers at any time and without notice.

The authors have taken due care in the preparation of this document and every attempt has been made to ensure its accuracy and completeness. In no event will Quatech, Inc. be liable for damages of any kind, incidental or consequential, in regard to or arising out of the performance or form of the materials presented in this document or any software programs that might accompany this document.

Quatech, Inc. encourages feedback about this document. Please send any written comments to the Technical Support department at the address listed on the cover page of this document.

DOS, Windows ME, Windows 2000, Windows 98, Windows 95, Windows NT are trademarks or registered trademarks of Microsoft Corporation. OS/2 is a registered trademark of IBM Corporation. All other trademarks or registered trademarks are property of their respective owners.

Page 4 of the Quatech Serial Device Server (DSC-100) user manual — Declaration of Conformity
Page 4 · click to enlarge
Page 4

Declaration of Conformity

Manufacturer's Name: Quatech Inc.

Manufacturer's Address662 Wolf Ledges Parkway Akron, Ohio 44311 (USA)
Application of Council Directive89/336/EEC

Standards to which Conformity is Declared: * EN50081-1 (EN55022, EN60555-2, EN60555-3) * EN50082-1 (IEC 801-2, IEC 801-3, & IEC 801-4)

Type of EquipmentInformation Technology Equipment
Equipment ClassCommercial, Residential, & Light Industrial
Product NamePCI Dual Serial Communications Card
Model NumberDSC-100/IND
Page 5 of the Quatech Serial Device Server (DSC-100) user manual — Untitled
Page 5 · click to enlarge
Page 5

6 1.1.1 "IND" Option --- Surge Suppression Upgrade 6 1.1 Features 5 1 General Information

7 2.2 Enable Scratchpad Register (SPAD, J8) 7 2.1 Factory Default Configuration 7 2 Hardware Configuration

8 2.3 Force High-Speed UART Clock (X2, X4, or X8, J5-J7)

9 2.4 DTE/DCE Selection

10 3 Hardware Installation

11 4 Address Map and Special Registers

11 4.1 Base Address and Interrupt Level (IRQ)

13 4.4 Options Register 12 4.3 Interrupt Status Register 12 4.2 Enabling the Special Registers

13 4.4.1 Enhanced Serial Adapter Identification

14 4.4.2 Clock Rate Multiplier

18 5.4 Windows 1995 17 5.3 Windows 98 16 5.2 Windows 2000 15 5.1 Windows Millennium 15 5 Windows Configuration

20 5.6 Viewing Resources with Device Manager 20 5.5 Windows NT

22 6.1.1 QTPCI.EXE 22 6 DOS and Other Operating Systems

25 7 OS/2

26 8 External Connections

28 9 PCI Resource Map

29 10 Specifications

31 11 Troubleshooting

Page 6 of the Quatech Serial Device Server (DSC-100) user manual — 1 General Information
Page 6 · click to enlarge
Page 6

1 General Information

The Quatech, Inc. DSC-100 provides two RS-232 asynchronous serial communication interfaces for IBM-compatible personal computer systems using the PCI expansion bus. The DSC-100 uses Quatech's new Enhanced Serial Adapter design. Legacy serial port data rates are limited to a maximum of 115,200 bits per second. Quatech Enhanced Serial Adapters can achieve data rates as high as 921,600 bits per second.

As a PCI device, the DSC-100 requires no hardware configuration. The card is automatically configured by the computer's BIOS or operating system. The two serial ports share a single interrupt line and are addressed in a contiguous block of 32 bytes. A special interrupt status register is provided to help software to manage the shared interrupt.

The DSC-100's serial ports use 16750 Universal Asynchronous Receiver/Transmitters (UARTs). These UARTs contain hardware buffers (FIFOs) which reduce processing overhead and allow higher data rates to be achieved. The 16750 contains a 64-byte FIFO and can transmit and receive data at a rate of up to 921,600 bits per second. The 16750 is recommended for heavy multitasking environments and for applications involving high data rates.

The DSC-100 is supported under several popular operating systems and environments. Contact the sales department for details on current software offerings. Most device drivers are available for download from the Quatech world wide web site at http://www.quatech.com

Page 7 of the Quatech Serial Device Server (DSC-100) user manual — 1.1.1 "IND" Option --- Surge Suppression Upgrade
Page 7 · click to enlarge
Page 7

1.1 Features

The standard DSC-100 implements each of its communication channels with a 16750 UART and uses standard line driver and receiver components. For improved performance and industrial-grade reliability, Quatech offers the following board upgrades:

1.1.1 "IND" Option --- Surge Suppression Upgrade

The "IND" option provides the protection essential for reliable use in an industrial environment. Each communication line has a surge suppressor capable of sustaining up to 40A 20us peak transient surges, a clamping voltage of 30V and a peak energy dissipation of 0.1 Joules.

Part NumberIND Option DSC-100no DSC-100INDyes

Figure 1 --- DSC-100 Product Series Summary

Page 8 of the Quatech Serial Device Server (DSC-100) user manual — J5
Page 8 · click to enlarge
Page 8

2 Hardware Configuration

The DSC-100 is automatically configured at boot time by the computer's BIOS or operating system. There are no required switches or jumpers to set for installation.

This chapter lists a number of optional jumper settings that control various hardware features. Jumpers J5-J8 are grouped together at the end of the board opposite the D-9 connectors. Any changes from the factory default should be made before installing the DSC-100 in the computer.

2.1 Factory Default Configuration

Figure 2 shows the jumper configuration as shipped from the factory, with two spare jumpers applied in neutral positions. Remove one or both and apply as shown in following sections to set optional features.

J5

J6

J7

J8

SPAD

Figure 2 --- Factory default jumper configuration

2.2 Enable Scratchpad Register (SPAD, J8)

In the default configuration, an Interrupt Status Register and an Options Register (see page 9) replace the scratchpad (base address + 7) of each UART. If the SPAD jumper is applied as in Figure 3, the UART scratchpad registers are enabled, and the Interrupt Status Register and the Options Register are not available.

J5

J6

J7

J8

SPAD

Figure 3 --- Enable scratchpad registers

Page 9 of the Quatech Serial Device Server (DSC-100) user manual — J5
Page 9 · click to enlarge
Page 9

2.3 Force High-Speed UART Clock (X2, X4, or X8, J5-J7)

These jumpers force an increase of the UART input clock frequency by a factor of two, four, or eight. This can allow legacy software to use baud rates above 115,200 bits per second. It is also useful if the serial port device driver does not directly support setting the higher baud rates through the Options Register (see page 12).

If one of these jumpers is applied, it overrides any value written to the Options Register to set the clock multiplier by software. The effective baud rate will be either two, four, or eight times the value for which the UART itself is programmed.

The factory default is none of these jumpers applied, which allows for software control of the clock multiplier via the Options Register. The Options Register powerup default is for a standard times-1 clock of 1.8432 MHz for compatibility with standard serial ports.

J5

J5

J6

J6

J7

J7

SPAD

SPAD

J8

J8

Factory default software control

Force times-two clock Baud rates up to 230.4 kbps

J5

J5

J6

J6

J7

J7

J8

SPAD

J8

SPAD

Force times-four clock Baud rates up to 460.8 kbps

Force times-eight clock Baud rates up to 921.6 kbps

Figure 4 --- Clock multiplier jumper options

Page 10 of the Quatech Serial Device Server (DSC-100) user manual — 2.4 DTE/DCE Selection
Page 10 · click to enlarge
Page 10

2.4 DTE/DCE Selection

To simplify connections to other devices, each port on the DSC-100 is equipped with a jumper block that allows the port to be configured as either a DTE- or DCE-type device. This allows the DSC-100 to connect to either DTE- or DCE-type devices without using a null modem cable. The DTE/DCE selection jumper blocks are illustrated in Figure 5.

J2 is used for serial port 1, closest to the bottom of the board.

J1 is used for serial port 2, closest to the top of the board.

Quatech Serial Device Server (DSC-100) — 2.4 DTE/DCE Selection diagram (page 10)
Fig. 2 · 2.4 DTE/DCE Selection

J2 -- Port 1 J1 -- Port 2 These jumper blocks are used to connect RS-232 signals to the various pins of the D-9 connectors.

Figure 5 --- DTE or DCE output selection

Page 11 of the Quatech Serial Device Server (DSC-100) user manual — J5 J6 J7 J8
Page 11 · click to enlarge
Page 11

3 Hardware Installation

1. Turn off the power of the computer system in which the DSC-100 is to be installed.
2. Remove the system cover according to the instructions provided by the computer manufacturer.
3. Make any desired optional jumper setting changes.
4. Install the DSC-100 in any empty PCI expansion slot. The board should be secured by installing the Option Retaining Bracket (ORB) screw.
5. Replace the system cover according to the instructions provided by the computer manufacturer.
6. Attach and secure the cable connectors to the desired equipment.
7. Turn on the power of the computer system.

The output of the DSC-100 is a pair of 9-pin D-connectors. All modem control signals (RTS, DTR, CTS, DSR, DCD, RI) are provided to each port.

J1 - Port 2

Clock multiplier/ scratchpad select Serial

J5 J6 J7 J8

X2 X4 X8 SPAD

J2 - Port 1

Figure 6 --- Jumper/connector locations

Show 4 more labels / short text on this page
Port · DTE/DCE Select · Serial · Port
Page 12 of the Quatech Serial Device Server (DSC-100) user manual — 4.1 Base Address and Interrupt Level (IRQ)
Page 12 · click to enlarge
Page 12

4 Address Map and Special Registers

This chapter explains how the two UARTs and special registers are addressed, as well as the layout of those registers. This material will be of interest to programmers writing driver software for the DSC-100.

4.1 Base Address and Interrupt Level (IRQ)

The base address and IRQ used by the DSC-100 are determined by the BIOS or operating system. Each serial port uses 8 consecutive I/O locations. The two ports reside in a single block of I/O space in eight-byte increments, along with a sixteen-byte reserved region, for a total of 32 contiguous bytes, as shown in Figure 7.

PortI/O Address Range Serial 1Base Address + 0 to Base Address + 7 Serial 2Base Address + 8 to Base Address + 15 (reserved)Base Address + 16 to Base Address + 31

Figure 7 --- Port Address Map

Both serial ports share the same IRQ. The DSC-100 signals a hardware interrupt when either port requires service. The interrupt signal is maintained until no port requires service. Interrupts are level-sensitive on the PCI bus.

The base address and IRQ are automatically detected by the device drivers Quatech supplies for various operating systems. For cases where no device driver is available, such as for operation under DOS, Quatech supplies the "QTPCI" DOS software utility for manually determining the resources used. See page 21 for details.

Page 13 of the Quatech Serial Device Server (DSC-100) user manual — 4.3 Interrupt Status Register
Page 13 · click to enlarge
Page 13

4.2 Enabling the Special Registers

The DSC-100 contains two unique registers, an Interrupt Status Register and an Options Register. These registers are enabled when the SPAD jumper (J8) is removed (factory default). They replace the UART Scratchpad Register on accesses to register address 7.

The Interrupt Status Register and Options Register are accessed through the scratchpad location of either UART. The DLAB bit of the UART (Line Control Register, bit 7) is used to select between the two registers. The most recent write of a DLAB bit in either UART selects between the two registers as shown in Figure 8.

address 7 accesses SPAD Jumper DLAB Bit

Options Register removed 1 Interrupt Status Register removed 0

Scratchpad Registers applied X

Figure 8 --- DLAB bit selects between special registers

4.3 Interrupt Status Register

The read-only Interrupt Status Register can be used to quickly identify which serial ports require servicing after an interrupt. Reading the Interrupt Status Register will return the interrupt status of the entire DSC-100, as shown in Figure 9. The individual bits are cleared as the interrupting ports are serviced. The interrupt service routine should ensure that the interrupt status register reads zero before exiting.

0 (not used) 7 (MSB)

0 (not used) 6

0 (not used) 5

0 (not used) 4

0 (not used) 3

0 (not used) 2

Port 2 --- 1 if interrupt pending 1

Port 1 --- 1 if interrupt pending 0

Figure 9 --- Interrupt Status Register

Register selected for · Description Bit

Page 14 of the Quatech Serial Device Server (DSC-100) user manual — 4.4.1 Enhanced Serial Adapter Identification
Page 14 · click to enlarge
Page 14

4.4 Options Register

The Options Register allows software to identify the DSC-100 as a Quatech Enhanced Serial Adapter. It also allows software to set the UART clock rate multiplier. Figure 10 shows the structure of the Options Register.

The powerup default of the Options Register is all bits zero.

ID bit 0 ID0 6 ID bit 1 ID1 7 (MSB)

(reserved, 0) - 4 (reserved, 0) - 5

(reserved, 0) - 3

Clock rate multiplier bit 1 RR1 1 (reserved, 0) - 2

Clock rate multiplier bit 0 RR0 0

Figure 10--- Options Register bit definitions

4.4.1 Enhanced Serial Adapter Identification

The ID bits are used to identify the DSC-100 is a Quatech Enhanced Serial Adapter. Logic operations are performed such that the values read back from these bits will not necessarily be the values that were written to them. Bit ID1 will return the logical-AND of the values written to ID[1:0], while bit ID0 will return their exclusive-OR.

Software can thus identify a Quatech Enhanced Serial Adapter by writing the ID bits with the patterns shown in the "write" column of Figure 11, then reading the bits and comparing the result with the patterns in the "read" column. Matching read patterns verify the presence of the Options Register.

0 1 0 0 1 1 0 1 0 ID0 ID1 ID0 ID1

Figure 11 --- ID bit write/read table

Description Name Bit · Read Write

Page 15 of the Quatech Serial Device Server (DSC-100) user manual — 4.4.2 Clock Rate Multiplier
Page 15 · click to enlarge
Page 15

4.4.2 Clock Rate Multiplier

A standard RS-232 serial port operates at a clock speed of 1.8432 MHz. In order to achieve higher data rates, Quatech Enhanced Serial Adapters can operate at two times, four times, or even eight times this standard clock speed. This is controlled by the clock rate multiplier bits in the Options Register.

Software can determine the UART clock frequency by reading the clock rate multiplier bits RR1 and RR0 in the Options Register as shown in Figure 12. RR1 and RR0 can be set by writing to the Options Register if the X2, X4, and X8 jumpers (J5-J7) are all removed. If one of these jumpers is applied, the RR1 and RR0 bits are forced to the appropriate value. Reading the Options Register will always return the clock rate multiplier at which the board is operating.

115.2 kbaud 1.8432 MHz X1 (default) 0 0

921.6 kbaud 14.7456 MHz X8 1 1 460.8 kbaud 7.3728 MHz X4 0 1 230.4 kbaud 3.6864 MHz X2 1 0

Figure 12 --- Rate Register bit definition

At powerup and reset, the Options Register is initialized to 0. The DSC-100 will thus powerup in the x1 mode with software control of the clock rate multiplier enabled as long as the X2, X4, and X8 jumpers are not installed.

Software can control high baud rates through a combination of changing the clock rate multiplier and the UART baud rate divisor. For example, a baud rate of 230.4 kbps could be achieved by setting the clock rate multiplier to X2 mode (or by applying the X2 jumper) and setting a software application for 115.2 kbps.

Show 4 more labels / short text on this page
Frequency Clock Rate · Rate UART Clock · Maximum Data · Multiplier RR0 RR1
Page 16 of the Quatech Serial Device Server (DSC-100) user manual — 5.1 Windows Millennium
Page 16 · click to enlarge
Page 16

5 Windows Configuration

5.1 Windows Millennium

1. After inserting the DSC-100 for the first time the "Add New Hardware Wizard" will begin. Select "Search for the best driver for your device.". Check the "Removable media" and "Specify location" box. Click the "Next" button.
Quatech Serial Device Server (DSC-100) — 5.1 Windows Millennium diagram (page 16)
Fig. 3 · 5.1 Windows Millennium
2. Window will locate the proper INF file and copy the file from the CD. Click

the "Next" button. 3. The final dialog screen will verify the file copy from the CD. Click the

"Finish" button.

Page 17 of the Quatech Serial Device Server (DSC-100) user manual — 5.2 Windows 2000
Page 17 · click to enlarge
Page 17

5.2 Windows 2000

1. After inserting a DSC-100 for the first time, the "Add New Hardware Wizard will appear at start up. Click the "OK" button.
Quatech Serial Device Server (DSC-100) — 5.2 Windows 2000 diagram (page 17)
Fig. 4 · 5.2 Windows 2000
2. The following dialog box insert the Communications Driver CD (shipped with

the device). Click the "OK" button.

Quatech Serial Device Server (DSC-100) — 5.2 Windows 2000 diagram (page 17)
Fig. 5 · 5.2 Windows 2000
3. The following dialog box will display the appropriate INF file on the CD in drive. Click the "OK" button.
4. Window will copy the INF file from the diskette and display a final dialog indication that the process is complete. Click the "Finish" button.
Page 18 of the Quatech Serial Device Server (DSC-100) user manual — 5.3 Windows 98
Page 18 · click to enlarge
Page 18

5.3 Windows 98

1. After inserting a DSC-100 for the first time, the "Add New Hardware Wizard will appear at start up. Click the "Next" button.
2. Select "Search for the best driver for you device". Click the "Next" button.
Quatech Serial Device Server (DSC-100) — 5.3 Windows 98 diagram (page 18)
Fig. 6 · 5.3 Windows 98
3. On the next dialog, select the "CD - ROM drive" check box. Insert the Communication Drivers CD (shipped with the device) into the CD - ROM drive. Click the "Next" button.
Page 19 of the Quatech Serial Device Server (DSC-100) user manual — 5.4 Windows 1995
Page 19 · click to enlarge
Page 19
Quatech Serial Device Server (DSC-100) — Untitled diagram (page 19)
Fig. 7 · Untitled
4. The following dialog box will display the appropriate INF file on the diskette in drive. Click the "Next" button.
5. Window will copy the INF file from the diskette and display a final dialog indication that the process is complete. Click the "Finish" button.

5.4 Windows 1995

Windows 95 maintains a registry of all known hardware installed in your computer. Inside this hardware registry Windows 95 keeps track of all of your system resources, such as I/O locations, IRQ levels, and DMA channels. The "Add New Hardware Wizard" utility in Windows 95 was designed to add new hardware and update this registry.

An "INF" configuration file is included with the DSC-100 to allow easy configuration in the Windows 95 environment. Also a custom Windows 95 serial device driver is included with the DSC-100 to support the use of the 16750 UART's 64 byte FIFO. Windows 95 uses the "INF" file to determine the system resources required by the DSC-100, searches for available resources to fill the boards requirements, and then updates the hardware registry with an entry that allocates these resources

The following instructions provide step-by-step instructions on installing the DSC-100 in Windows 95 using the "New Hardware Found" wizard.

Page 20 of the Quatech Serial Device Server (DSC-100) user manual — Untitled
Page 20 · click to enlarge
Page 20
1. After booting the computer with a newly-installed DSC-100, the "New Hardware Found" dialog box will appear. If you have never installed a Quatech PCI communications adapter before, the dialog box may simply indicate that it has found a "PCI Card."
2. Select the radio button for "Driver from disk provided by hardware manufacturer." Click the "OK" button to continue.

3. An "Install From Disk" dialog box should pop up. Insert the diskette with the Quatech INF files on it, select the correct drive letter, and click the "OK" button. Windows 95 automatically browses the root directory for an INF file that defines configurations for Multi-function Adapters. If no INF files are found, click the "Browse" button and search the Win95 sub directory on the installation diskette. You are not required to select the file name. After finding the directory containing the INF files, Windows 95 will choose the correct file.

4. The "New Hardware Found" dialog box will appear again, this time for an "Unknown Device."
5. Again select the radio button for "Driver from CD provided by hardware manufacturer." Click the "OK" button to continue.
6. Another "Install From CD" dialog box will pop up. The path should already be pointing to the Quatech CD. Click the "OK" button to continue.
7. You should now see the "Copying Files" dialog box as Windows 95 copies the driver files from the CD.
8. The installation utility will ask for your Windows 95 installation disks. Serial communication ports require two drivers supplied by Microsoft to function: SERIAL.VXD and SERIALUI.DLL. Insert the disk or CD and click "OK".

latest version of these files installed. If you do not have your Windows 95

install disks immediately available, click "OK" anyway. A dialog box appears with an option to Skip the files. Click the Skip button and the files

will not be installed. This is all right if the latest version of these drivers

are currently in the \WINDOWS\SYSTEM directory.

9. The "New Hardware Found" dialog will repeat as each serial port is registered with Windows 95.
10. Installation is complete.
Page 21 of the Quatech Serial Device Server (DSC-100) user manual — 5.6 Viewing Resources with Device Manager
Page 21 · click to enlarge
Page 21

5.5 Windows NT

The Windows NT device driver is installed by running the SETUP program. Up to 256 serial ports are supported. There is a command line-based configuration utility which is used for adding PCI bus and ISA bus serial ports. Please refer to the documentation included with the device driver for full installation and configuration details.

5.6 Viewing Resources with Device Manager

The following instructions provide step-by-step instructions on viewing resources used by the DSC-100 in Windows using the "Device Manager" utility. Select Start|Help from within Windows for additional information on this utility.

1. Double click the "System" icon inside the Control Panel folder. This opens up the System Properties box.
2. Click the "Device Manager" tab located along the top of the System Properties box. This lists all hardware devices registered inside the Windows registry. Additional information is available on any of these devices by click on the device name and then selecting the "Properties" button.
3. Double click the device group "Multi-function Adapters". The DSC-100 model name should appear in the list of Multi-function adapters.
4. Double click the DSC-100 model name and a properties box should open for the hardware adapter.
5. Click the "Resources" tab located along the top of the properties box to view the resources Windows has allocated for the DSC-100 match the hardware configuration. Because PCI is a true plug-and-play bus, do not attempt to modify the configuration values listed. Click "Cancel" to exit without making changes.
6. The DSC-100 serial ports are also listed under the group Ports (COM and LPT). Windows 95 does not assign COM1-COM4 to ports addressed at nonstandard locations. The DSC-100 ports will be enumerated starting with COM5 (or higher) even if lower logical numbers are available.
7. Select any of the Quatech Serial Ports listed under the group Port (COM and LPT) and click the "Properties" button. This action opens a properties dialog for the specific COM port on the DSC-100.
8. Click the "Port Settings" tab and then click the "Advanced" button. The DSC-100 driver will display a custom Advanced Port Settings control, which allows the
Page 22 of the Quatech Serial Device Server (DSC-100) user manual — Untitled
Page 22 · click to enlarge
Page 22

ports UART compatibility mode and FIFO threshold levels to be configured. The threshold values of full-scale for the transmit buffer and 3/4-scale for the receive buffer shown below are optimal for most applications. Note that the FIFO option for each of the DSC-100's two ports is configured independently.

9. Use the Logical COM Port names to access the serial ports on your DSC-100 through your software applications. Note: The Logical COM Port name is assigned to your ports by Windows 95. This name is required by a Windows 95 application when accessing a particular port.
Page 23 of the Quatech Serial Device Server (DSC-100) user manual — 6.1.1 QTPCI.EXE
Page 23 · click to enlarge
Page 23

6 DOS and Other Operating Systems

The DSC-100 is not a direct drop-in replacement for a legacy serial port because its base address and IRQ cannot be fixed at values such as 3F8 hex, IRQ 4 (COM1) or 2F8 hex, IRQ 3 (COM2), etc. Rather, the system BIOS assigns the address and the IRQ in a plug-and-play fashion at boot time. Software which is to use the DSC-100 must be able to accommodate any valid assignments of these resources.

For Windows and OS/2, the Quatech device drivers determine what the resource assignments are and proceed accordingly. In other cases, however, the user must intervene. The discussion below will center on DOS, but the concepts can be applied to other operating systems as well.

Many DOS applications support user configuration of the base address and IRQ of a serial port. Such applications can generally make use of the DSC-100. Older applications, as well as some custom software, may use hard-coded standard legacy serial port addresses. These applications will require modifications if they are to use the DSC-100.

Custom applications for which the customer has source code can be modified to make just a few PCI BIOS function calls to obtain all the necessary configuration information. The PCI BIOS specification can be obtained from the PCI Special Interest Group. Contact Quatech technical support for more information.

6.1.1 QTPCI.EXE

Quatech's "QTPCI" utility supplies the information required when modifying the serial port settings of the application. This program should be run from real DOS, not in a Windows DOS box.

Figure 15 shows the Basic Mode display for the DSC-100 after the "Q" key has been pressed. In this example, the DSC-100 uses I/O base address FC20 hex and IRQ 11. The hardware revision of the DSC-100 is also displayed. Pressing the "N" key will show similar information for all non-Quatech PCI devices in the system, including those devices integrated on the motherboard.

Page 24 of the Quatech Serial Device Server (DSC-100) user manual — Untitled
Page 24 · click to enlarge
Page 24

The QTPCI program is capable only of displaying the PCI configuration. It

cannot be used to make changes.

Quatech PCI Configuration Information Display Software Version 1.00

INSTRUCTIONS: Press keys listed in the menu at the bottom of the screen. This program only displays information. It cannot make changes.

Numbers preceeded by "0x" are hexadecimal

PCI BIOS detected, version 2.10

Quatech PCI adapters detected DSC-100 Two-port RS-232 adapter (Hardware Revision A1) Uses IRQ 11 Base addr 1 = 0xfe80 I/O _

Q - Quatech PCI adapters N - Other PCI devices X - EXIT

M - Change to Expert Mode

Figure 15 --- QTPCI.EXE Basic Mode display

Figure 16 shows the Expert Mode display for the DSC-100 after the "Q" key has been pressed. The information from the Basic Mode display is presented along with

Page 25 of the Quatech Serial Device Server (DSC-100) user manual — Untitled
Page 25 · click to enlarge
Page 25

more details such as the Vendor and Device IDs, PCI Class Code, size of memory and I/O regions, etc. Pressing the "N" key will show similar information for all non-Quatech PCI devices in the system, including those devices integrated on the motherboard. In this example, the "Base addr 0" resource is reserved.

For users interested in even more details, PCI BIOS information can be displayed by pressing the "B" key. Pressing the "I" key displays the PCI interrupt routing table.

Quatech PCI Configuration Information Display Software Version 1.00

Quatech PCI adapters detected DSC-100d Two-port RS-232 adapter Vendor ID 0x135c, Device id 0x0020 found in slot 0x04 on bus 0x00 Device/function code = 0x98, Revision ID = 0x01 (Hardware revision A1) PCI Class Code = 0x070200 Communications controller, multiport serial Subsystem Vendor ID 0x135c, Subsystem Id 0x0050 INTA# mapped to IRQ 11 (route 0x62) Base addr 0 = 0xfc80 I/O 0X80 bytes allocated Base addr 1 = 0xfc20 I/O 0x20 bytes allocated _

M - Change to Basic Mode

Q - Quatech PCI adapters N - Other PCI devices X - EXIT

B - PCI BIOS details I - Interrupt routing details

Figure 16 --- QTPCI.EXE Expert Mode display

Page 26 of the Quatech Serial Device Server (DSC-100) user manual — Untitled
Page 26 · click to enlarge
Page 26
Page 26 of the Quatech Serial Device Server (DSC-100) user manual — Untitled
Page 27 of the Quatech Serial Device Server (DSC-100) user manual — 7 OS/2
Page 27 · click to enlarge
Page 27

7 OS/2

The OS/2 device driver supports up to 32 serial ports in a system. Installation is a manual, but simple, process. Please refer to the documentation included with the device driver for full installation and configuration details.

Device drivers for Windows NT and OS/2 are also available for the DSC-100. The board can be used under DOS and other operating systems as well in many circumstances. The software described below can be downloaded from the Quatech web site if it did not come with the board.

Page 28 of the Quatech Serial Device Server (DSC-100) user manual — RI DCD
Page 28 · click to enlarge
Page 28

8 External Connections

RS-232-C devices are classified by their function as either Data Terminal Equipment (DTE) or Data Communication Equipment (DCE). Generally, data terminal equipment is defined as the communication source and data communication equipment is defined as the device that provides a communication channel between two DTE-type devices.

RS-232-C

DTE

DCE

RS-232-C

DTE

DCE

Figure 17 --- Use of DTEs and DCEs in a communications link

DTE- and DCE-type devices have complementary pinouts to allow terminals and modems to be connected directly using a one-to-one cable as shown in Figure 18. In many applications, DCEs are unnecessary, and in these cases a cable called a "null modem cable" or "modem eliminator cable" is used to directly connect two DTE-type devices. A typical null modem cable is also shown in Figure 18.

(3) (2) (4) (5) (20)

(3) (2) (4) (5) (20)

RxD TxD RTS CTS DTR DSR DCD

RxD TxD RTS CTS DTR DSR DCD

(3) (2) (4) (5) (20) (6) (8) (22) (7) RI

TxD RxD CTS RTS DSR DTR DCD

(3) (2) (4) (5) (20)

RxD TxD RTS CTS DTR DSR

RxD TxD RTS CTS DTR DSR

(3) (2) (4) (5) (20)

RI DCD

RI DCD

RI DCD

RI

GND

GND

GND

GND

GND

GND

Typical DTE-to-DTE null modem cable

Figure 18 --- Cabling requirements for RS-232-C devices

(cables using 25-pin connectors shown)

Show 16 more labels / short text on this page
Terminal · Modem · Telephone · line · Terminal · Modem · (6) · (6) (8) (22) · (6) (8) (22) · (6) (8) (22) · (8) (22) (7) · (8) (22) (7) · (7) · (7) · (7) · Typical DTE-to-DCE cable
Page 29 of the Quatech Serial Device Server (DSC-100) user manual — Untitled
Page 29 · click to enlarge
Page 29

The DSC-100 is a DTE device which connects to peripheral equipment through two male D-9 connectors. An adapter cable providing two male D-25 connectors is available. The standard serial port connections are listed in Figure 19.

Quatech Serial Device Server (DSC-100) — Untitled diagram (page 29)
Fig. 8 · Untitled

Figure 19 --- DS-100 connector definitions for EIA/TIA-232-E

Quatech Serial Device Server (DSC-100) — Untitled diagram (page 29)
Fig. 9 · Untitled

Figure 20 --- DS-100 Output connectors

Page 30 of the Quatech Serial Device Server (DSC-100) user manual — 9 PCI Resource Map
Page 30 · click to enlarge
Page 30

9 PCI Resource Map

Listed below are the PCI resources used by the DSC-100. Such information may be of use to customers writing their own device drivers or other custom software. A detailed description of the DSC-100's UARTs is available on the Quatech web site.

(all numbers in hex)

PCI Vendor ID: 0x135C Quatech, Inc.

PCI Device ID0x0020 DSC-100
Base class0x07 Simple communications controller Subclass: 0x02 Multiport serial controller Interface: 0x00
IRQ sourced byINTA#
Base address 00x80 bytes I/O Reserved region
Base address 10x20 bytes I/O Serial ports

Port 1 at offset 0x00 Port 2 at offset 0x08 reserved region 0x10-0x1F

PCI Class Code

Page 31 of the Quatech Serial Device Server (DSC-100) user manual — 10 Specifications
Page 31 · click to enlarge
Page 31

10 Specifications

Bus interface PCI, 32-bit bus, 5-volt only

Dimensionsapprox. 5.0" x 3.7"

Controller: 16750 with 64-byte FIFOs Interface: Two male D-9 connectors, or two male D-25 connectors optional using adapter cables

Transmit drivers: SN75150 or compatible High-level output: +5V min, +8V typical Low-level output: -5V max, -8V typical Switching speed low-to-high: 1.4 µs with 2500 pF load 40 ns with 15 pF load high-to-low: 1.5 µs with 2500 pF load 20 ns with 15 pF load

Receive buffers: MC1489 or compatible High-level input: +3V to +13V Low-level input: -3V to -13V Switching speed: 120 ns typical, 175 ns max

+5 voltsapprox. 240 mA +/-12 volts: approx. 10 mA
Temperatureoperating 0 ° to 70 ° storage -50 ° to 80 °
Humidity10% to 90%

IBM-compatible computers · Serial ports · Power requirements

Page 32 of the Quatech Serial Device Server (DSC-100) user manual — Untitled
Page 32 · click to enlarge
Page 32

Maximum Load (pF) Data Rate

5030 4400 3500 1670 800 115.2 2100 1670 1200 1000 330 230.4 1000 900 670 430 100 460.8 470 430 200 100 N/A 921.6

Note 1: The signal transition time ratio is defined as the percentage of the unit interval or bit time (the inverse of the data rate) that is occupied by the signal transitioning from -3V to +3V. The EIA/TIA-232-E standard defines a maximum signal transition time ratio of 4%; most RS-232 receivers will recognize signal transitions with much larger ratios. With a 4% signal transition time ratio, EIA/TIA-232-E is limited to a theoretical data rate of 200 kbaud. If maximum signal transition time ratio is extended to 10%, 15%, 20%, or even 25%, the maximum data rate achievable using EIA/TIA-232-E can be increased past 200 kbaud.

Show 11 more labels / short text on this page
4% trans · 10% trans · 15% trans · 20% trans · 25% trans · (kbaud) · time · time · time · time · time
Page 33 of the Quatech Serial Device Server (DSC-100) user manual — 11 Troubleshooting
Page 33 · click to enlarge
Page 33

11 Troubleshooting

Listed here are some common problems and frequent causes of those problems. If the information here does not provide a solution, contact Quatech technical support.

Any unauthorized repairs or modifications will void the DSC-100's warranty.

Computer will not boot up.

1. Is the DSC-100 properly inserted? Remove the card and try again. Perhaps try a different expansion slot.
2. Ensure that an ISA-bus card is not using the same IRQ that the PCI BIOS tries to assign to the DSC-100. Most computers have BIOS setup options to reserve IRQs for either ISA or PCI use. Try reserving the IRQ for the ISA card. The BIOS will automatically choose a different IRQ for the DSC-100. An address conflict is unlikely because most PCI-based computers will assign I/O addresses in such a way that they cannot conflict with ISA-bus devices.
3. The DSC-100 may be defective. Contact technical support for instructions.

Cannot communicate with other equipment.

1. Are the cable connections correct? Are the cables securely attached?
2. Is the software configured with the correct base address and IRQ information for the DSC-100? (This is mainly a DOS issue.)
3. Is the device driver installed?
4. If you are trying to communicate with another DTE, a null-modem cable will be required.
5. If possible, use a loopback connector to test the port. This connector needs to connect the following sets of signals on a D-9 connector:

TxD and RxD (pins 3 and 2) RTS and CTS (pins 7 and 8) DCD, DTR, DSR, and RI (pins 1, 4, 6 and 9)

Page 34 of the Quatech Serial Device Server (DSC-100) user manual — Untitled
Page 34 · click to enlarge
Page 34

DSC-100 User's Manual Revision 1.10 June 2001 P/N: 940-0138-110

Ask about the Quatech Serial Device Server (DSC-100)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Quatech Serial Device Server (DSC-100)

Be the first to ask — other owners or our team will answer.

Original document

Quatech Serial Device Server (DSC-100) manual PDF

34 pages·420 KB·Network Card·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…