Instruction/ maintenance manual of the product QVI30S Quadra-Fire
Go to page of 45
1 Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 Model(s): QVI30S QVI35S • Do not store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - Do not try to light any appliance - Do not touch any electrical switch.
Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 2 Congratulations Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: _____.
3 Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 T able of Contents 1 Listing and Code Approvals A. Appliance Certi fi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 B. BTU Speci fi cations . . . . . . . . . . . . . . .
Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 4 Note : T o assure top performance, safety and ef fi ciency , inserts must be installed with an approved fl ue liner as per CAN/CGA B-149 or National Fuel Gas Code ANSI Z223 and these instructions.
5 Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 Quadra-Fire gas inserts are designed for recessed installa- tions into solid fuel masonry or factory built non-combustible fi replaces that have been installed in accordance with the National, Provincial, State and local building codes.
Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 6 T OP VIEW A C B 3 3 F ireplace Size Requirements Figure 3.1 Fireplace Opening NOTE: For actual appliance dimensions refer to Section 15.
7 Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 B. Clearances Figure 3.2 Clearances to Mantels or other Combustibles above Appliance Fire Risk. • Locate and install appliance to all clearance speci fi cations in manual. Fire Risk. Odor Risk.
Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 8 Fire Risk. Asphyxiation Risk. • T erminations MUST meet minimum clearances. • Exhaust gases are hot. • Nearby vents may draw fumes into house. A. V ent T ermination Minimum Clearances Figure 4.
9 Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 CAUTION ALL vent speci fi cations MUST be followed. • This product is tested and listed to these speci fi cations. • Appliance performance will suffer if speci fi cations are not followed.
Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 10 6 6 Installation Preparation Fire Risk. A hearth or hearth extension (if present) must comply with either of the following: • The solid fuel burning fi replace manufacturer’s speci fi cation.
11 Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 A. V enting Components 7 7 Installing V ent P ipe and Appliance The vertical vent termination system installed on this model includes: • One length of 3-inch fl exible vent pipe for combustion air (included with vent kit).
Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 12 Figure 7.2 CUT AND BEND FLASHING AS NEEDED TO FIT CHIMNEY SEALANT ADHESIVE • T rim chimney top plate to minimize excess overhang or bend over fl ue tile (see Figure 7.2). • Place 3/8 inch bead of 300º F silicone on fl ue tile top.
13 Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 D. Installing Adaptor and T ermination Cap For installation of termination cap see minimum vent heights for various pitched roofs (see Figure 7.2) . T o install adaptor see Figure 7.3. Roof Pitch H (Min.
Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 14 • Ensure that gas line does not come in contact with outer wrap of appliance. Follow local codes. • Incoming gas line should be piped into the valve compartment and connected to the 1/2 inch connection on the manual shutoff valve.
15 Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 Fire hazard. Do NOT change the valve settings. • This valve has been preset at the factory . • Changing valve settings may result in fi re hazard or bodily injury . HIGH AL TITUDE INST ALLA TIONS U.
Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 16 A. Wiring the Appliance 9 9 Elect rical Infor mation Note : This appliance must be electrically wired and grounded in accordance with local codes or , in the absence of local codes, with National Electric Code ANSI/NFP A 70-latest edition or the Canadian Electric Code, CSA C221.
17 Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 B. Junction Box Installation Figure 9.2 Junction box installation JUNCTION BOX SIDEW ALL JUNCTION BOX ACCESS SCREW PROVIDED Optional Accessories Connecting the electrical junction box is required if using a blower or remote.
Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 18 Figure 9.4 Fan/Rheostat Wire Diagram NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH TYPE 105 0 C RA TED WIRE.
19 Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 A. Mantel Projections Figure 10.1 shows the minimum vertical and corresponding maximum horizontal dimensions of appliance mantels or other combustible projections above the top front edge of the appliance, not the surround.
Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 20 Figure 1 1.1 Placement of Embers 1 1 11 Appliance Setup A. Remove Shipping Materials Remove shipping materials from inside or underneath the fi rebox. B. Clean the Appliance Clean/vacuum any sawdust that may have accumulated inside the fi rebox or underneath in the control cavity .
21 Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 Step 3: Install the left side refractory in the same manner (see Figure 1 1.4). Step 2: While holding the back wall in place, install the right side refractory . Bend down the small tab located on the top front edge of the fi rebox (see Figure 1 1.
Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 22 Log Set Assembly: LOGS-QVI30 F . Positioning the Logs CAUTION: Logs are fragile! Carefully remove the logs from the packaging. If the gas logs have been factory installed they should not need to be positioned.
23 Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 Log #2 (srv340-702): Position log #2 by locating its slot over the tab on the front left of the burner . The slot in the left e nd of the log slides into the vertical metal edge in front of the square cut out on the base pan.
Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 24 Log #5 (srv340-706): Place log #5 across log #1 and log # 3. The notch in the bottom of the log sets on the carved out edge on top of log #3. The back of the log sits in the grooved out area in log #1.
25 Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 Log Set Assembly: LOGS-QVI35 CAUTION: Logs are fragile! Carefully remove the logs from the packaging. 1 1 2 2 3 3 6 6 5 5 4 4 1 1 PILOT PILOT T AB TA B T AB TA B BURNER BURNER BASEP AN BASEP AN Log #1 (srv330-701): Place log #1 in the back on the insert.
Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 26 3 3 3 3 4 4 Log #3 (srv330-703): Position log #3 by locating its slot over the tab on the right front of the burner . The right end of log #3 is pushed up against the step in the base pan.
27 Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 Figure 1 1.5 Glass Assembly G. Glass Assembly H. Air Shutter Setting Optimal fl ame appearance is dependent on the air shutter setting. Adjustments should be made by a qualified technician.
Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 28 Fire Risk. Explosion Risk. Gas may build up while lighting pilot. • Remove glass assembly before lighting pilot. • Replace glass assembly after lighting pilot. A. Before Lighting Appliance This appliance has a Standing Pilot Ignition.
29 Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 B. Lighting Appliance Standing Pilot Ignition 1. T urn off all electric power to the appliance if service is to be performed. 2. Open control access panel. 3. Move switch to “OFF” position.
Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 30 C. Check Pilot Flame Appearance Pilot fl ame must contact the thermocouple and thermopile for reliable appliance operation.
31 Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 E. Frequently Asked Questions Fire Risk. High T emperatures. Keep combustible household items away from appliance. Do NOT obstruct combustion and ventilation air . • Do NOT place combustible items on top of or in front of appliance.
Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 32 A. Standing Pilot Ignition System 1 3 13 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.
33 Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 T roubleshooting (continued) Symptom Possible Cause Corrective Action 3. Continued c. Defective valve. T urn the valve knob to the ON position. Place the ON/OFF switch in the ON position. Check the millivolt meter a the thermopile terminals.
Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 34 1 4 14 Maintaining and Ser vicing Appliance Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a quali fi ed service technician should perform an appliance checkup at the beginning of each heating season.
35 Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 Inspect Maintenance T asks Doors, Surrounds and Fronts 1. Assess condition of screen and replace as necessary . Recommend addition of screen if one is not present. 2. Inspect for scratches, dents or other damage and repair as necessary .
Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 36 Figure 15.1 Appliance Dimensions 1 5 15 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. Fo r framing dimensions and clearances refer to Section 3.
37 Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 B. V ent Kits Components Direct V ent Flex Liner Kits (see Figure 15.2) LINK-DV30B : Masonry 3 inch fl ex liner kit. Sections expand to 30 feet. Includes: two liners, termination cap, fl ashing, and link adapter .
Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 38 Service Parts Diagram QVI30S Beginning Manufacturing Date: Aug. 2007 Ending Manufacturing Date: ______ R C.
39 Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 Service Parts Diagram QVI30S Service Parts R IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 40 Service Parts Diagram QVI35S Beginning Manufacturing Date: Aug. 2007 Ending Manufacturing Date: ______ Service Parts R 7 8 9 10 11 12 13 14 15 16 17 18 19 Part number list on following page.
41 Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 Service Parts Diagram QVI35S Service Parts R IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 42 IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer .
43 Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 D. Limited Lifetime W arranty Î.
Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 44.
45 Quadra-Fire • QVI30S, QVI35S • 340-901 Rev . i • 6/09 E. Contact Information - NOTES - ________________________________________________________________________________ _______________________.
An important point after buying a device Quadra-Fire QVI30S (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Quadra-Fire QVI30S yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Quadra-Fire QVI30S - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Quadra-Fire QVI30S you will learn all the available features of the product, as well as information on its operation. The information that you get Quadra-Fire QVI30S will certainly help you make a decision on the purchase.
If you already are a holder of Quadra-Fire QVI30S, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Quadra-Fire QVI30S.
However, one of the most important roles played by the user manual is to help in solving problems with Quadra-Fire QVI30S. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Quadra-Fire QVI30S along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center