www .quadrafire.com September 1, 2008 R GARNET -T DIRECT VENT ROOM HEA TER Owner ’ s Manual Installation and Operation Model: 7016-127F GARNET -MBK GARNET -D-MBK GARNET -D-PMH GARNET -D-CSB GARNET -D-CWL O-T L T ested and Listed by Portland Oregon USA OMNI-T est Laboratories, Inc.
Page 2 Quadra-Fire · Garnet-T · 7016-127F September 1, 2008 and Welcome to the Quadra-Fire Family ! Hearth & Home T echnologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality , durability , and performance.
Page 3 Quadra-Fire · Garnet-T · 7016-127F - T ABLE OF CONTENTS - September 1, 2008 Section 1: Listing and Code Approvals A. Appliance Certifications ...................... 4 B. Glass Specifications ............................ 4 C. BTU Specifications .
Page 4 September 1, 2008 Quadra-Fire · Garnet-T · 7016-127F 1 Listing and Code Approvals The product is listed to ANSI standards for “V ented Gas Appliance Heaters” and applicable sections of “Gas Burning Heating Appliances for Manufactured Homes and Recre- ational V ehicles” and "Gas Fired Appliances for use at High Altitudes".
September 1, 2008 Page 5 Quadra-Fire · Garnet-T · 7016-127F NOTE: The following requirements reference various Massachusetts and national codes not contained in this document.
Page 6 September 1, 2008 Quadra-Fire · Garnet-T · 7016-127F 2 Getting Started Check building codes prior to installation. • Installation MUST comply with local, regional, state and national codes and regulations.
September 1, 2008 Page 7 Quadra-Fire · Garnet-T · 7016-127F 3 Appliance Location and Clearances A. Selecting Appliance Location NOTE: · Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONL Y . · Illustrations/diagrams are not drawn to scale.
Page 8 September 1, 2008 Quadra-Fire · Garnet-T · 7016-127F 4 T ermination Locations A. V ent T ermination Minimum Clearances Gas T ermination Wood & Fuel Oil T ermination Comments A 6 in. 20 in. min. Horizontal distance between terminations B 20 in.
September 1, 2008 Page 9 Quadra-Fire · Garnet-T · 7016-127F Figure 4.4 V = VENT TERMINAL X = AIR SUPPL Y INLET = AREA WHERE TERMINAL IS NOT PERMITTED A = 12 inche s ............. clearances above grade , veran- da, porch, deck or balcony B = 1 2 i n ch es .
Page 10 September 1, 2008 Quadra-Fire · Garnet-T · 7016-127F 5 V ent Information A. V enting Components B. Use of Elbows In order to comply with applicable codes and product warranties, use only fol.
September 1, 2008 Page 1 1 Quadra-Fire · Garnet-T · 7016-127F D. How to Use the V ent Graph E. V enting Guidelines Figure 5.2 VERTICAL DIST ANCE FROM APPLIANCE TO 90° ELBOW EXCEPTIONS FOR HORIZONT AL INST ALLA TIONS: T he maximum horizontal vent run is 30 in.
Page 12 September 1, 2008 Quadra-Fire · Garnet-T · 7016-127F Female Locking Lugs Male Locking Lugs Step 1. Determine the desired location of the appliance. Check to ensure that wall studs or roof rafters are not in the way when the venting system is attached.
September 1, 2008 Page 13 Quadra-Fire · Garnet-T · 7016-127F NOTE: (1) Installation requires a minimum of 6 in. (152mm) horizontal run of vent with a 1/4 in. (6mm) rise run towards the termination. Each 1 ft. (305mm) of horizontal venting must include a 1/4 in.
Page 14 September 1, 2008 Quadra-Fire · Garnet-T · 7016-127F Fold Strap Here Wall Thimble Cover/Ceiling Firestop as Required by Local Jurisdiction 1/4 in.
September 1, 2008 Page 15 Quadra-Fire · Garnet-T · 7016-127F Step 1. Check the installation instructions for required 1 in. (25mm) clearances (air space) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafters, or other nearby combustible surfaces.
Page 16 September 1, 2008 Quadra-Fire · Garnet-T · 7016-127F Step 4. Assemble the desired lengths of pipe and elbows necessary to reach from the appliance up through the round support box. Ensure that all pipe and elbow connections are in their fully twist-locked position.
September 1, 2008 Page 17 Quadra-Fire · Garnet-T · 7016-127F Step 8. Slip the storm collar over the pipe, and push it down to the top of the flashing ( Figure 5.15 ). Use non-hardening sealant above and below the joint between the storm collar and the pipe.
Page 18 September 1, 2008 Quadra-Fire · Garnet-T · 7016-127F 2. Cathedral Ceiling Level Cathedral Ceiling Support Box 2 in. (51mm) Min. below finished ceiling Cut hole 1/8 in. (3mm) greater in size than pattern of support box as it is projected onto roof line Figure 5.
September 1, 2008 Page 19 Quadra-Fire · Garnet-T · 7016-127F High Wind T ermination Cap Sheet Metal Screws Drill Four 1/8 in. (3mm) Diamater Holes Figure 5.22 Figure 5.23 Step 4. Pass the flex pipe down through the center of the chimney system, and center the top adapter on the top of the chimney pipe.
Page 20 September 1, 2008 Quadra-Fire · Garnet-T · 7016-127F 4. Existing Masonry Chimney Figure 5.24 T ype C - Up & Out Installation T ype A & B - Co-Axial to Co-Linear Chimney Liner T ermination Cap Co-Axial to Co-Linear Connector 25 ft. (8m) of 3 in.
September 1, 2008 Page 21 Quadra-Fire · Garnet-T · 7016-127F 10 in. x 10 in. (254mm x 254mm) framed opening in wall Studwall Masonry Chimney Retro Connector (4) Masonry Bolts (Not Included) Wa ll Thimble Cover Figure 5.
Page 22 September 1, 2008 Quadra-Fire · Garnet-T · 7016-127F High Wind T ermination Cap T op Adaptor (3) Sheet Metal Screws Flashing Step 9. Attach the flex to the retro connector. Use three sheet metal screws to attach the flex liner to the connector ( Figure 5.
September 1, 2008 Page 23 Quadra-Fire · Garnet-T · 7016-127F 3/4 3/4 3/4 BEFORE YOU BEGIN: Review the venting configurations in Figures A, B and C on the next page . H. Slim Line W all Thimble 1. Assembling Slim Line T rim Ring and Heat Shield 2. Installing Slim Line T rim Ring and Heat Shield Figure 5.
Page 24 September 1, 2008 Quadra-Fire · Garnet-T · 7016-127F FIG. A 90 DEGREE ELBOW FIG. C MINIMUM CLEARANCE Figure 5.33 FIG. B 45 DEGREE ELBOW TERMINA TION CAP HEA T SHIELD OVER TOP HALF OF PIPE TRIM RING W ALL THIMBLE CENTER LINE MINIMUM OF 6 in. (152Mm) OF PIPE THROUGH THE WALL INTERIOR W ALL (2 in.
September 1, 2008 Page 25 Quadra-Fire · Garnet-T · 7016-127F 6 Gas Information A. Fuel Conversions Before making gas connections ensure that the appliance being installed is compatible with the available gas type.
Page 26 September 1, 2008 Quadra-Fire · Garnet-T · 7016-127F A B C Mounting Screws Pressure Regulator T ower Diaphragm Figure 6.5 T urn control knob to the OFF position, ensure that gas supply to the valve has been turned off.
September 1, 2008 Page 27 Quadra-Fire · Garnet-T · 7016-127F B. Gas Pressures If the pressure is not sufficient, ensure: 1) the piping used is large enough. 2) the supply regulator is adequately adjusted. 3) that the total gas load for the residence does not exceed the amount supplied.
Page 28 September 1, 2008 Quadra-Fire · Garnet-T · 7016-127F • A small amount of air will be in the gas supply lines. When first lighting appliance it will take a short time for air to purge from lines. When purging is complete the appliance will light and operate normally .
September 1, 2008 Page 29 Quadra-Fire · Garnet-T · 7016-127F 7 Electrical Information A. Recommendation for Wire C. Standing Pilot Ignition System Wiring See B5 below for recommended maximum lead length (two wire) when using wall thermostat/switch. B.
Page 30 September 1, 2008 Quadra-Fire · Garnet-T · 7016-127F Figure 7.1 CAUTION Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. V erify proper operation after servicing. Shock hazard.
September 1, 2008 Page 31 Quadra-Fire · Garnet-T · 7016-127F 8 Appliance Setup A. Remove Shipping Materials Remove shipping materials from inside or underneath the firebox. B. Leg Leveling System Figure 8.1 Thread Allen bolts through nuts until flush.
Page 32 September 1, 2008 Quadra-Fire · Garnet-T · 7016-127F D. Accessories Install approved accessories per instructions included with accessories. Refer to Section 12 for appropriate accesso- ries. Shock or fire risk. Use ONL Y optional accessories approved for this appliance.
September 1, 2008 Page 33 Quadra-Fire · Garnet-T · 7016-127F H. Blower Installation 11 10 KIT CONTENTS: 1 - Blower Mounted in Housing 2 - Speed Control Knob 3 - Pal Nut 4 - Ceramic Snap Disc 5 - Spe.
Page 34 September 1, 2008 Quadra-Fire · Garnet-T · 7016-127F Figure 8.12 Install the snap disc. A snap disc bracket is located in the appliance's component bag. Bend the two spade temi- nals on the snap disc from a horizontal to a vertical position.
September 1, 2008 Page 35 Quadra-Fire · Garnet-T · 7016-127F Figure 8.15 Blower Wiring Diagram Fan Speed Control Thermal Disc (1 10 V AC) Power Cord BLACK Bushing Strain Relief GREEN BLACK Ground Fa.
Page 36 September 1, 2008 Quadra-Fire · Garnet-T · 7016-127F I. Ignition Module Access and Battery Replacement Figure 8.16 The ignition module is located under the appliance attached to the decorative cover . Lift off the appliance top and place it on a flat surface, with the porcelain side up to prevent damage.
September 1, 2008 Page 37 Quadra-Fire · Garnet-T · 7016-127F 9 Operating Instructions A. Before Lighting Appliance Read this entire manual prior to using the appliance. Failure to follow the instructions may result in property damage, bodily injury, or even death.
Page 38 September 1, 2008 Quadra-Fire · Garnet-T · 7016-127F C. Lighting Appliance 1. Set the thermostat to lowest setting. 2. T urn off all electric power to the appliance if service is to be performed. 3. Push in gas control knob slightly and turn clockwise to "OFF" position.
September 1, 2008 Page 39 Quadra-Fire · Garnet-T · 7016-127F D. After Appliance is Lit When you light your appliance, you may notice that it pro- duces heat which does have an associated odor or smell.
Page 40 September 1, 2008 Quadra-Fire · Garnet-T · 7016-127F 10 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.
September 1, 2008 Page 41 Quadra-Fire · Garnet-T · 7016-127F Symptom Possible Cause Corrective Action 3. (Continued) c. Defective valve. T urn the valve knob to the ON position. Place the ON/OFF switch in the ON position. Check the millivolt meter at the thermopile terminals.
Page 42 September 1, 2008 Quadra-Fire · Garnet-T · 7016-127F 11 Maintaining and Servicing Y our Appliance Although the frequency of your appliance servicing and maintenance will depend on use and the type of installation, a qualified service technician should perform an appliance check-up at the beginning of each heating season.
September 1, 2008 Page 43 Quadra-Fire · Garnet-T · 7016-127F Inspect Maintenance T asks Doors 1. Inspect for scratches, dents or other damage and repair as necessary . 2. V erify no obstructions to air flow . 3. V erify maintenance of proper clearance to combustible household objects.
Page 44 September 1, 2008 Quadra-Fire · Garnet-T · 7016-127F 12 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions.
September 1, 2008 Page 45 Quadra-Fire · Garnet-T · 7016-127F B. V ent Components Diagram Figure 12.2 SL-D Series V ent Components 4 in. (102 mm) inner pipe 6-5/8 in. (168 mm) outer pipe 9-1/4 in. (235mm) 6-1/2 in. (165mm) 6-5/8 in. (168mm) 17-24 in.
Page 46 September 1, 2008 Quadra-Fire · Garnet-T · 7016-127F C. V ent Components List Description HHT SL-P M= Multi Pack (6) Simpson Dura-V ent DirectV ent Pro Selkirk Direct-T emp Amerivent Direct .
September 1, 2008 Page 47 Quadra-Fire · Garnet-T · 7016-127F 45° Elbow , Swivel, Black - 46DV A-E45B - - SV4EB45 90° Elbow , Galvanized SLP90M See Swivel 4DT -EL905 4D90LS - 90° Elbow , Black SLP.
Page 48 September 1, 2008 Quadra-Fire · Garnet-T · 7016-127F D. Service Parts List R GARNET -T (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: 6-16-04 Ending Manufacturing Date: Item #.
September 1, 2008 Page 49 Quadra-Fire · Garnet-T · 7016-127F IMPORT ANT : THIS IS DA TED INFORMA TION. The most current information is located on your dealer's VIP site. When ordering, supply serial and model numbers to ensure correct service parts.
Page 50 September 1, 2008 Quadra-Fire · Garnet-T · 7016-127F Hinge Pins, Gold (set of 2) 844-5750 6 Ignition Module 230-1880 Injector , Pilot, EZ, LP , 35 200-2630 3 Knob, Extension, HI/LO, S.
September 1, 2008 Page 51 Quadra-Fire · Garnet-T · 7016-127F IMPORT ANT : THIS IS DA TED INFORMA TION. The most current information is located on your dealer's VIP site. When ordering, supply serial and model numbers to ensure correct service parts.
Page 52 September 1, 2008 Quadra-Fire · Garnet-T · 7016-127F Date of Service Performed By Description of Service F . Service And Maintenance Log.
September 1, 2008 Page 53 Quadra-Fire · Garnet-T · 7016-127F G. Homeowner ’ s Notes.
Page 54 September 1, 2008 Quadra-Fire · Garnet-T · 7016-127F H. W arranty Policy Hearth & Home T echnologies LIMITED W ARRANTY Hearth & Home T echnologies (“HHT”) and its respective bran.
September 1, 2008 Page 55 Quadra-Fire · Garnet-T · 7016-127F HHT’s obligation under this warranty does not extend to damages resulting from: (1) installation, operation or main- tenance of the.
Page 56 Quadra-Fire · Garnet-T · 7016-127F September 1, 2008 Hearth & Home T echnologies 1445 North Highway Colville, W A 991 14 Division of HHT INDUSTRIES CONT ACT INFORMA TION : DEALERSHIP WHE.
An important point after buying a device Quadra-Fire Direct Vent Room Heater GARNET-D-CSB (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Quadra-Fire Direct Vent Room Heater GARNET-D-CSB yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Quadra-Fire Direct Vent Room Heater GARNET-D-CSB - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Quadra-Fire Direct Vent Room Heater GARNET-D-CSB you will learn all the available features of the product, as well as information on its operation. The information that you get Quadra-Fire Direct Vent Room Heater GARNET-D-CSB will certainly help you make a decision on the purchase.
If you already are a holder of Quadra-Fire Direct Vent Room Heater GARNET-D-CSB, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Quadra-Fire Direct Vent Room Heater GARNET-D-CSB.
However, one of the most important roles played by the user manual is to help in solving problems with Quadra-Fire Direct Vent Room Heater GARNET-D-CSB. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Quadra-Fire Direct Vent Room Heater GARNET-D-CSB along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center