EX16650 U SER M ANUAL
Version 2.0 SR2

© 2008 Promise Technology, Inc. All Rights Reserved.
Copyright by Promise Technology, Inc. (Promise Technology). No part of this manual may be reproduced or transmitted in any form without the expressed, written permission of Promise Technology.
Promise, and the Promise logo are registered in U.S. Patent and Trademark Office. All other product names mentioned herein may be trademarks or registered trademarks of their respective companies.
You should back up all data before installing any drive controller or storage peripheral. Promise Technology is not responsible for any loss of data resulting from the use, disuse or misuse of this or any other Promise Technology product.
Although Promise Technology has attempted to ensure the accuracy of the content of this manual, it is possible that this document may contain technical inaccuracies, typographical, or other errors. Promise Technology assumes no liability for any error in this publication, and for damages, whether direct, indirect, incidental, consequential or otherwise, that may result from such error, including, but not limited to loss of data or profits.
Promise Technology provides this publication “as is” without warranty of any kind, either express or implied, including, but not limited to implied warranties of merchantability or fitness for a particular purpose.
The published information in the manual is subject to change without notice. Promise Technology reserves the right to make changes in the product design, layout, and driver revisions without notification to its users.
This version of the User Manual supersedes all previous versions.
In this Manual, the appearance of products made by other companies, including, but not limited to software, servers, and physical drives, is for the purpose of illustration and explanation only. Promise Technology does not recommend, endorse, prefer, or support any product made by another manufacturer.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy, and, if not installed and used in accordance with the instruction may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
This device complies with Part 5 of the FCC Rules. Operation is subject to the following conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Only digital device equipment CERTIFIED CLASS B should be attached to this equipment and that must have shielded cables.




Thank you for purchasing one of Promise Technology’s SuperTrak EX4650, EX8650, EX8654, EX8658, or EX16650 SAS/SATA RAID Controller card.
This User Manual describes how to setup, use and maintain the SuperTrak RAID controller. It also describes how to use the Web-Based Promise Array Management—Professional (WebPAM PRO) RAID management software.
This manual includes a full table of contents, chapter task lists and numerous cross-references to help you find the specific information you are looking for.
Also included are four levels of notices:
A Note provides helpful information such as hints or alternative ways of doing a task.
A Caution informs you of possible equipment damage or loss of data and how to avoid them.
A Warning notifies you of probable equipment damage or loss of data, or the possibility of physical injury, and how to avoid them.

SuperTrak EX4650, EX8650, EX8654, EX8658, and EX16650 are SAS and SATA RAID Controller cards. When used with WebPAM PRO software, the SuperTrak RAID Controllers offer a feature-rich, secure and versatile enterprise- wide RAID solution. In addition, the SuperTrak EX Series supports RAID expansion. The resulting RAID environment allows users and administrators to configure, manage, and monitor everything from single logical drives on local systems to logical drive networks residing in offsite locations.
The SuperTrak EX Series RAID Controller cards support SAS hard drives as well as 1.5 Gb/s and 3.0 Gb/s SATA hard drives. At its core, the SuperTrak card provides advanced RAID management functions: creating logical drives, monitoring them, keeping them online and operating at optimum efficiency. SuperTrak can also perform many other tasks, such as:
The SuperTrak EX Series Controllers have an onboard microprocessor for XOR calculations, which off loads the parity calculation workload from the main CPU and transfers it to the controller card, boosting the performance of the entire system.
Attached drives can be hot swapped when necessary.

The Web-Based Promise Array Management—Professional (WebPAM PRO) software offers local and remote management and monitoring of all SuperTrak logical drives that exist anywhere on a network. Browser-based GUI provides email notification of all major events or alarms, memory cache management, drive event logging, logical drive maintenance, rebuild, and access to all components in the RAID configuration (controller, physical drives, disk arrays, logical drives, physical drives, and enclosure).
For information on using WebPAM PRO, see “Chapter 5: Management with WebPAM PRO” on page 107.
On the Host PC where you install the SuperTrak controller and WebPAM PRO, Promise Technology recommends:
SuperTrak management on the following OS is supported only via CLI:
SuperTrak management on the following virtualization platform is supported only via CLI:

On the Host PC where you install the SuperTrak controller and WebPAM PRO, you must have one of the following browsers:
If you do not have one of the above browsers, install the browser first and make it the default browser. Then install WebPAM PRO.
The following information offers an overview of the major features of the Promise SuperTrak EX4650, EX8650, EX8654, EX8658, and EX16650.
Supports PCIe x8 bus motherboards
Allows maximum data transfers of up to 2 GB/s in both directions simultaneously to dramatically reduce the time to save and retrieve large files.
EX4650 supports: RAID 0, 1, 1E, 5, 6, and 10. RAID 50 and 60 with SAS Expander. Provides dramatic increase in drive performance and/or fault tolerant options. Offers performance customization and data rebuilds from the BIOS menu. EX8650, EX8654, EX8658, and EX16650 support: RAID 0, 1, 1E, 5, 6, 10, 50, and 60
Supports Serial ATA Specification II
Burst data transfer rates up to 300 MB/s from Serial ATA drives to boost overall system performance.
Supports Serial Attached SCSI Specification
Burst data transfer rates up to 300 MB/s from SAS drives to boost overall system performance.
Independent data channels for SATA and SAS drives
Drives can multiply their data transfer performance when striped together and each drive uses a separate data channel.
Supports multiple logical drives on the same physical drives
Up to 32 logical drives per array, Up to 128 arrays drives per controller, Up to 128 physical drives per controller, Up to 256 logical drives per controller.
Advanced Hardware Design · Features Benefits

Supports online logical drive expansion
Add disk drives to the array without affecting data availability.
Supports online logical drive migration
Change RAID level without affecting data availability.
Utilizes SuperBuild™ automenu from the SuperTrak onboard BIOS
Has “Auto Setup” option for quick and easy logical drive builds.
Displays status and error checking messages during bootup
Notifies user of possible errors and allows for recovery of mirrored drive logical drives directly from SuperBuild™.
Supports S.M.A.R.T. monitoring and reporting
Polls status at set intervals, reports through WebPAM PRO.
Employs the latest Promise PCI Express SATA/SAS ASIC technology
Fully supports Serial ATA specifications with 150 and 300 MB/sec timing and CRC error-checking at high speeds.
Fault tolerance can be restored automatically without rebooting.
DOS based flash upgrade of BIOS and Firmware
Verifies proper file, option to backup existing file. Download files from Promise website.
Capacity coercion Supports four schemes of capacity coercion.
System reboot not required after create, delete, migrate or expand logical drive
System boot process continues without restarting.
Complies with PCI Express Specification 1.0a
Provides highest level of hardware compatibility
Complies with SATA Specification 1.0a
Provides full compatibility with first generation SATA hard drives.
Provides enclosure and drive monitoring compatibility.
Complies with SAS Specification 1.1
Provides full compatibility with SAS hard drives.

Tested compatibility to coexist with motherboards that have integrated IDE controllers
Improves system performance and minimizes system conflicts for new and existing installations.
Features LBA support Supports drives greater than 137 GB capacity.
Supports BIOS Boot Specification
All logical drives attached to the SuperTrak card appear in the BBS-compliant motherboards BIOS boot list.
EX8650: 256 MB
EX8654, EX8658, EX16650: 512 MB
Compatibility · Features Benefits

When you receive the SuperTrak EX Series SAS/SATA RAID Controller card, the package should contain the items listed below:
If any of the items are missing or appear damaged, please contact your dealer or distributor immediately.
The electronic components on the SuperTrak EX Controller cards are sensitive to damage from Electro-Static Discharge (ESD). Observe appropriate precautions at all times when handling the SuperTrak card or its subassemblies.

Before installing the SuperTrak EX Controller card into an existing system, backup any important or useful data. Failure to follow this accepted PC practice could result in data loss.
Promise does not recommend multi-lane and fanout cables longer than 1m (38 inches) because they have not been tested with the SuperTrak controller.
If your SuperTrak EX16650 card has a battery backup unit (BBU), follow these requirements to be sure the battery charges properly:
The SuperTrak EX Controller cards are PCI Plug-n-Play (PnP) devices. No changes are necessary in the motherboard CMOS or BIOS Setup for resources or drive types in most applications.

The SuperTrak EX Controller card fits into any available PCI-Express x8 slot. You can also plug the SuperTrak card into a PCI-Express x16 slot.

External SAS multi-lane cables are user-supplied. The external SAS ports have SFF-8088 connectors.
See Figures 1 through 5.

Figure 1. SuperTrak EX4650 card

Global and Aggregate LED Pins
Figure 2. SuperTrak EX8650 card

Global and Aggregate LED Pins

Figure 3. SuperTrak EX8654 card

Figure 4. SuperTrak EX8658 card


Figure 5. SuperTrak EX16650 card
Activity and Fault LED Pins

Global and Aggregate LED Pins
For more information, see the user manual for your enclosure or SAS expander.
For more information, see “Appendix D: LED Backplane Connections” on page 291 and the user manual for your PC or enclosure.
Figure 6. Individual LED pins, EX4650, EX8650, and EX8654
EX4650
EX8654
8 7 6 5 4 3 2 1
1 2 3 4

For SuperTrak EX8654 and EX8658, note that only the interior SAS Ports have individual LED pins.
Figure 7. Individual LED pins, EX16650
Activity LEDs Fault LEDs
1 2 3 4 5 6 7 8 9 10 11 1213 14 15 16
Figure 8. Global and Aggregate LED pins, EX4650 and EX8650
+ – – +
Figure 9. Global and Aggregate LED pins, EX8654 and EX8658
Aggregate LEDs Global LEDs
Figure 10. Global and Aggregate LED pins, EX16650

If you are using Promise SuperSwap enclosures:
SuperTrak supports up to eight SuperSwap 1600 enclosures or up to two SuperSwap 4600 enclosures.
If you are connecting the SuperTrak card to a single VTrak JBOD enclosure, you can attach the SAS multi-lane cable to either the circle or diamond port on the enclosure.
However, if you plan to cascade multiple VTrak JBOD enclosures, you must attach the SAS multi-lane cable to the circle port on the first enclosure.
Figure 11. Attaching the SAS multi-lane cable to the diamond port

VTrak JBOD enclosure SuperTrak Controller
SAS multi-lane cable (supplied with VTrak)

The table below correlates the ranges of Enclosure IDs and Physical Drive IDs, that appear in the WebPAM PRO interface as a result of the data connections you make.
SuperTrak SAS Port Enclosure ID Range Drive ID Range
Ch1-4 Virtual* 1 1 to 128
Ch1-4 2 to 9 1 to 128
Ch5-8 10 to 17 129 to 256
Ch9-12 18 to 25 257 to 384
Ch13-16 26 to 33 385 to 512
* A virtual enclosure involves physical drives attached directly to the SuperTrak controller or a connection to an SGPIO backplane.
You can attach up to 128 SAS or SATA drives on each SAS port using SAS expanders.
The SuperTrak EX8650, EX8654, and EX8658 cards are designed to manage up to 16 enclosures and up to 256 SAS or SATA disk drives (using SAS expanders).
The SuperTrak EX16650 card is designed to manage up to 32 enclosures and up to 512 SAS or SATA disk drives (using SAS expanders).
If your system has fewer components, you might be surprised at the way WebPAM PRO numbers your enclosures and drives. The following scenarios illustrate some numbering examples.
You install the SuperTrak card into an SGPIO enclosure. You attach a SAS data cable between Port Ch1-4 and the enclosure’s backplane.
In WebPAM PRO, the SGPIO enclosure appears as Enclosure 1. The drives are numbered 1 to 128.
If you attached a second SGPIO enclosure to Port Ch5-8, it would appear in WebPAM PRO as Enclosure 10. The drives would be numbered 129 to 256.
You install the SuperTrak card into a Host PC. You attach SAS breakout cables to Ports Ch1-4 and Ch5-8 and a SAS or SATA drive at the drive ends of each cable.

In WebPAM PRO, the Host PC appears as Enclosure 1. The drives on Port Ch1-4 are numbered 1 to 4. The drives on Port Ch5-8 are numbered 129 to 132.
This scenario also applies if you use Promise SuperSwap enclosures.
You install the SuperTrak card into a Host PC. You attach a SAS data cable between Port Ch1-4 and a Promise VTrak J310s 12-drive JBOD enclosure. You connect a second J310s enclosure to the first in a daisy chain.
In WebPAM PRO, the first JBOD enclosure appears as Enclosure 2. The drives are numbered 1 to 12. The second JBOD enclosure appears as Enclosure 3. The drives are numbered 13 to 24.
You install the SuperTrak card into a Host PC. You attach a SAS data cable between Port Ch1-4 and a VTrak J310s enclosure. You attach a SAS data cable between Port Ch5-8 and a second J310s enclosure.
In WebPAM PRO, the first JBOD enclosure appears as Enclosure 2. The drives are numbered 1 to 12. The second JBOD enclosure appears as Enclosure 10. The drives are numbered 129 to 140.
You install the SuperTrak card into a Host PC. You attach a SAS data cables between Ports Ch1-4 and Ch5-8 and two SAS Expanders.
In WebPAM PRO, the first Expander appears as Enclosure 2. The drives are numbered 1 to 128. The second Expander appears as Enclosure 10. The drives are numbered 129 to 256.
See “Viewing Enclosure Information” on page 145 and “Locating a Physical Drive” on page 146 for more information.

The SuperTrak EX Controller card supports SAS and 1.5-Gb/s or 3.0-Gb/s SATA physical drives. For optimal performance, install physical drives of the same model and capacity.
Level Number of Drives Level Number of Drives
RAID 0 1 or more RAID 6 4 to 16*
RAID 1 2 only RAID 10 4 or more**
RAID 1E 3 or more RAID 50 6 or more
RAID 5 3 to 16* RAID 60 8 or more
* Requires SAS expansion
** Requires an even number of drives
The table above shows the number of drives required for each RAID level.

You can use the SuperBuild™ Configuration Utility to create a logical drive with the attached physical drives. Even if you plan to use the WebPAM PRO software to manage your logical drives, you can still create your first logical drive using the SuperBuild Utility, as described here.
For an explanation of the logical drive concepts and the choices you can make when you create your logical drive, see “Chapter 7: Technology Background” on page 219 of this manual.




The Disk Array Management screen appears.

The Create Disk Array screen appears.

Use this screen to select the physical drives for your disk array.
An asterisk (*) appears at the left of each selected physical drive.
The Disk Array Management screen appears, showing your new disk array


The Main Menu appears.

The Logical Drive Management screen appears.

The Create Logical Drive Step 1/2 screen appears.
An asterisk (*) appears at the left of the chosen disk array.


The Create Logical Drive Step 2/2 screen appears.

In the popup menu, highlight your choice of RAID Level and press Enter.
The available RAID Levels depend on the number of physical drives you selected for your disk array.
Press the Delete or Backspace keys to erase the current capacity. Type the new capacity in MB to allocate to this logical drive.
Later, you can assign the unused capacity to a second logical drive.
Highlight your choice of 64 KB, 128 KB, 256 KB, 512 KB, or 1024 KB and press Enter.
Use the default 512 B. Only exceptions are logical drives larger than 2 TB on Windows XP 32-bit. See page 246 for more information.

Highlight your choice of Write Through or Write Back and press Enter.
Highlight your choice of None, Read Cache, or Read Ahead and press Enter.
The Logical Drive Management screen appears with your new logical drive.

At this point you can create additional logical drives, if there is physical drive space available. To create another logical drive, repeat steps 4 though 18 above.
Do not press the Ctrl-Alt-Del keys. Do not press the Esc key.
You have successfully created a new RAID logical drive.
You must partition and format your new logical drive before you can use it. Use the same method of partitioning and formatting a logical drive as you would any other fixed disk added to your computer system.

The Command Line Interface (CLI) provides rapid setup of disk arrays and logical drives. You can also manage your SuperTrak system using the CLI.
To install the CLI onto your Windows PC or server:
If the computer is already running, exit all programs. If you are not logged in as the Administrator, log out, then log in again as the Administrator.
The installer window opens automatically.
The first CLI installation dialog box appears.
Figure 12. Introduction dialog box

The CLI uses the same installer as WebPAM PRO. Even though the dialog boxes say “WebPAM PRO,” this procedure installs the CLI.

Figure 13. License Agreement dialog box


When you agree with the proposed installation folder, click the Next button.
Figure 14. Choose Destination Location dialog box


Figure 15. Ready to Install dialog box


Figure 16. Install Complete dialog box

With the Register Your Product Online box checked, your browser will open and go directly to the Promise product registration website. Thank you for taking the time to register.
To open the CLI, click the CLI icon on the desktop (right).
Go to “Chapter 6: Management with the CLI” on page 149 for information about using this application.

Check the SuperTrak Read Me file for any issues pertaining to the distribution and version of Linux OS running on your PC or server.
For Linux PCs, Promise offers two different binary files:
To install the CLI onto your Linux PC or server:
If the computer is already running, exit all programs. If you are not logged in as root, log out, then log in again as root.
After several moments, the first installation dialog box appears.

Figure 17. Introduction dialog box


Figure 18. License Agreement dialog box


When you agree with the proposed installation folder, click the Next button.
Figure 19. Choose Install Folder dialog box


Figure 20. Pre-Installation Summary dialog box


Figure 21. Install Compete dialog box


Figure 22. Register On-line dialog box

With the Register Your Product On-line box checked, your browser will open and go directly to the Promise product registration website. Thank you for taking the time to register.
Go to the /opt/Promise/WebPAMPRO/Agent/bin directory and type ./cliib to start the CLI.
Go to “Chapter 6: Management with the CLI” on page 149 for information about using this application.

PCs running FreeBSD do not support WebPAM PRO, therefore they cannot use the WebPAM PRO installer. Those systems use a binary file to install the CLI in a terminal window.
Choose the x64 binary file for a 64-bit OS or the x86 binary file for a 32-bit OS.
To install the CLI onto your FreeBSD PC or server:
If the computer is already running, exit all programs. If you are not logged in as root, log out, then log in again as root.
sh CLI_Installer...FreeBSD.bin -i silent
and press Enter.
CLI_Installer...FreeBSD.bin represents the exact name of the CLI binary file, such as CLI_Installer_3_11_0000_00_x64FreeBSD.bin, or CLI_Installer_3_11_0000_00_x86FreeBSD.bin
After the installation is finished, type cliib with any shell to start the CLI.
Go to “Chapter 6: Management with the CLI” on page 149 for information about using this application.

The VMware virtualization platfrom does not support WebPAM PRO, therefore they cannot use the WebPAM PRO installer. Those systems use a binary file to install the CLI in a terminal window.
Before you begin, download the CLI_Installer...VMware.bin file from the Promise Support Website to your PC or server.
To install the CLI onto your VMware platform:
If the computer is already running, exit all programs. If you are not logged in as root, log out, then log in again as root.
sh CLI_Installer...VMware.bin -i silent
and press Enter.
CLI_Installer...VMware.bin represents the exact name of the CLI binary file, such as CLI_Installer_3_11_0000_00_VMware.bin
After the installation is finished, go to the /opt/Promise/WebPAMPRO/Agent/bin directory and type ./cliib to start the CLI.
Go to “Chapter 6: Management with the CLI” on page 149 for information about using this application.

Web-Based Promise Array Management—Professional (WebPAM PRO) software provides a browser-based graphic user interface used to monitor and manage Promise RAID products and their logical drives. Because it works over your network, it can monitor and control multiple systems.
WebPAM PRO involves four components:
When you install WebPAM PRO on a PC or server, you are installing the Utility Server, Agent, and JRE.
The Utility Server can run on the Host PC (where the SuperTrak card is installed), or on a networked PC, if your WebPAM PRO system includes remote management over a network. You run the Utility Server by directing your browser to the IP address of the Host PC.
The Agent runs on the Host PC (where the SuperTrak card is installed). After you have logged into the Utility Server through WebPAM PRO, the Utility Server accesses the Agent on the Host PC. As the user, you do not access the Agent directly.
On the Host PC where you install the SuperTrak controller and WebPAM PRO, Promise Technology recommends:

Choose one of these operating systems to take full advantage of all the features of WebPAM PRO.
The WebPAM PRO installation program installs a private Java Runtime Environment (JRE) under the same directory where WebPAM PRO is installed. WebPAM PRO uses this private JRE to avoid incompatibility issues with any other JREs that may be present on your system.
Typically an Internet browser comes with your operating system. The WebPAM PRO installer does not include a browser. For computers that will remotely monitor and manage the RAID, the browser is the only software required.
Choose the latest version of the following browsers to use with WebPAM PRO:
If you do not have one of the above browsers on the Host PC, install the browser first and make it the default browser. Then install WebPAM PRO.
Install the SuperTrak driver for your operating system before installing WebPAM PRO. See “Chapter 3: Installing Drivers” on page 59 for instructions.

If you have WebPAM or an earlier version of WebPAM PRO on your PC or server, manually uninstall them before you install WebPAM PRO from the Software CD.
Go to one of the following procedures:
To install WebPAM PRO onto your Windows-based PC or server:
If the computer is already running, exit all programs. If you are not logged in as the Administrator, log out, then log in again as the Administrator.
The installer window opens automatically.
The first WebPAM PRO installation dialog box appears.
Figure 23. Introduction dialog box


Figure 24. License Agreement dialog box


Click the Next button to continue.
Figure 25. Setup Type dialog box


Checked items will be installed. Uncheck items you do not want to install.
Click the Next button to continue.
Figure 26. Custom Setup dialog box


When you agree with the proposed installation folder, click the Next button.
Figure 27. Choose Destination Location dialog box


External SSL Security – Applies security to all connections involving the Internet or outside your company firewall.
Security options are invisible to authorized users.
Promise Technology provides a default certificate for the server as well as for internal data communication. However, in some cases it is better to install and verify your own certificate for the webserver. And, if possible, verify the certificate by a certificate authority such as Verisign or Thwate. See your MIS Administrator for guidance.
Click the Next button to continue.
Figure 28. WebPAM PRO Server dialog box

If you are only installing the CLI, this dialog box does not appear.

Figure 29. Ready to Install dialog box


Figure 30. Install Complete dialog box

With the Register Your Product Online box checked, your browser will open and go directly to the Promise product registration website. Thank you for taking the time to register.
This completes the WebPAM PRO installation for Windows. Go to “Logging into WebPAM PRO” on page 55.

Check the SuperTrak Read Me file for any issues pertaining to the distribution and version of Linux OS that you are running.
To install WebPAM PRO onto your Linux-based PC or server:
If the computer is already running, exit all programs. If you are not logged in as root, log out, then log in again as root.
After several moments, the first WebPAM PRO installation dialog box appears.
Figure 31. Introduction dialog box


Figure 32. License Agreement dialog box


Checked items will be installed. Uncheck items you do not want to install.
Click the Next button to continue.
Figure 33. Choose Install Product dialog box


When you agree with the proposed installation folder, click the Next button.
Figure 34. Choose Install Folder dialog box


External SSL Security – Applies security to all connections involving the Internet or outside your company firewall.
Security options are invisible to authorized users.
Promise Technology provides a default certificate for the server as well as for internal data communication. However, in some cases it is better to install and verify your own certificate for the webserver. And, if possible, verify the certificate by a certificate authority such as Verisign or Thwate. See your MIS Administrator for guidance.
Click the Next button to continue.
Figure 35. SSL Security Options dialog box

If you are only installing the CLI, this dialog box does not appear.

Figure 36. Pre-Installation Summary dialog box


Figure 37. Install Compete dialog box


Figure 38. Register On-line dialog box

With the Register Your Product On-line box checked, your browser will open and go directly to the Promise product registration website. Thank you for taking the time to register.
The first time you install WebPAM PRO on a RedHat Linux system, the WebPAM PRO icon appears on the desktop but not in the application menu. Please log out, then log in again, and the WebPAM PRO icon will thereafter appear in the application menu.
This completes the WebPAM PRO installation for Linux. Go to “Logging into WebPAM PRO” on page 55.

You can log into WebPAM PRO in either of two ways:
At the Host PC (where the SuperTrak EX Controller is installed), do one of the following actions:
You can log into WebPAM PRO from any PC with a network connection to the Host PC (where the SuperTrak EX Controller is installed).
If you selected External SSL Security during installation (Windows, see page 44; Linux, see page 51), use the Secure Connection. Otherwise, use the Regular Connection.
Together, your entry looks like this:
http://192.168.10.228:8080/promise

Together, your entry looks like this:
https://192.168.10.228:8443/promise
When the opening screen appears:
The User Name and Password are case sensitive. See Figure 39.
Figure 39. The WebPAM PRO login screen


The first time you use WebPAM PRO, you must add the Host PC so that WebPAM PRO will recognize it. You only need to perform this procedure once.
To add the Host PC:
See Figure 40.
Figure 40. WebPAM PRO initial login screen

If you are working at the same Host PC where the SuperTrak card is installed, you can also type 127.0.0.1 in the IP address field.
Entries such as localhost or the Host PC’s network name do not work for this function.
Click Subsystem/Host Management

Figure 41. Add Subsystem/Host tab

The newly added host appears in the Tree, on the left side of the WebPAM PRO screen.
This completes the WebPAM PRO installation and initial setup. Go to “Chapter 5: Management with WebPAM PRO” on page 107 for information about using this application.

Following are installation procedures for the SuperTrak drivers for Windows, Linux, and FreeBSD included on the software CD.
Download the latest drivers from the Promise Support Website.
The software CD also includes source code files for compiling your own Linux drivers. Source code files begin with the letters SRC.

If you are using a Linux distribution for which there are no compiled drivers, please access the Promise Knowledge Base and call up Article 10029.
Windows
If your Windows PC does not have a floppy drive, copy the driver file to a CD or a USB stick, whichever your PC supports.
To prepare a driver diskette, CD, or USB stick for Windows:
Check the driver’s ReadMe file for important information.

For BSD, start with a diskette. For Linux, choose the medium that works for your system.
If your Linux PC does not have a floppy drive, copy the driver file to a CD or a USB stick, whichever your PC supports.
To prepare a driver diskette, CD, or USB stick for Linux:
tar zxvf RH-306010003.tar.gz
Check the driver’s ReadMe file for important information.

New OS Installation
The following details the installation of the SuperTrak EX Series RAID Controller drivers while installing Windows Server 2008.

After installing the SuperTrak EX Series RAID Controller card and rebooting your system, Windows Server 2008 setup will show a “Found New Hardware” dialog box.
The “Found New Hardware – RAID Controller” dialog box displays the message: “Allow Windows to search online for driver software for your RAID Controller?”
The “Found New Hardware – RAID Controller” dialog box displays the message: “Insert the disc that came with your RAID Controller.”
Windows loads the driver and displays the “Found New Hardware” dialog box with message: “Windows has finished installing the driver software for this device Promise SuperTrak EX [4650, 8650, 8654, 8658, 16650] (tm) Controller.”

New OS Installation
The following details the installation of the SuperTrak EX Series RAID Controller drivers while installing Windows Vista.

After installing the SuperTrak EX Series RAID Controller card and rebooting your system, Windows Vista setup will show a “Found New Hardware” dialog box.
The “Found New Hardware – RAID Controller” dialog box displays the message: “Allow Windows to search online for driver software for your RAID Controller?”
The “Found New Hardware – RAID Controller” dialog box displays the message: “Insert the disc that came with your RAID Controller.”
Windows loads the driver and displays the “Found New Hardware” dialog box with message: “Windows has finished installing the driver software for this device Promise SuperTrak EX [4650, 8650, 8654, 8658, 16650] (tm) Controller.”

New OS Installation
The following details the installation of the SuperTrak EX Series RAID Controller drivers while installing Windows Server 2003.

After installing the SuperTrak EX Series RAID Controller card and rebooting your system, Windows Server 2003 setup will show a “Found New Hardware” dialog box. Under Windows 2003, “RAID Controller” will be displayed.

New OS Installation
The following details the installation of the SuperTrak EX Series RAID Controller drivers while installing Windows XP.

After installing the SuperTrak EX Series RAID Controller card and rebooting your system, Windows XP setup will show a “Found New Hardware” dialog box.

New OS Installation
At the Devices dialog box, insert the driver diskette or CD, or attach the USB stick and click OK.
Change this command as needed for a CD or USB stick.
Change this command as needed for a CD or USB stick.
Change this command as needed for a CD or USB stick.

New OS Installation
At the Devices dialog box, insert the driver diskette or CD, or attach the USB stick and click OK.
Change this command as needed for a CD or USB stick.
Change this command as needed for a CD or USB stick.
Change this command as needed for a CD or USB stick.

New OS Installation
A prompt labeled boot: will appear at the bottom of the screen.
At the Devices dialog box, insert the driver diskette or CD, or attach the USB stick and click OK.
Change this command as needed for a CD or USB stick.
Change this command as needed for a CD or USB stick.
Change this command as needed for a CD or USB stick.

New OS Installation
Then click OK and click Back to return to the installer.
Change this command as needed for a CD or USB stick.
Change this command as needed for a CD or USB stick.
Change this command as needed for a CD or USB stick.

New OS Installation
Then click OK and click Back to return to the installer.
Change this command as needed for a CD or USB stick.
Change this command as needed for a CD or USB stick.
Change this command as needed for a CD or USB stick.

New OS Installation
Change this command as needed for a CD or USB stick.
Change this command as needed for a CD or USB stick.
Change this command as needed for a CD or USB stick.

New OS Installation
set currdev=disk0 load /stex.ko set currdev=cd0 boot
Press Alt-F4 to switch to another screen.
Type the following command and press Enter.
mount -t msdos /dev/fd0 /cdrom /cdrom/install
mount -t msdos /dev/daXsX /cdrom /cdrom/install
Where /dev/daXs is the device node for the USB device.
ls /dev/fd0 · umount /cdrom

Change this command as needed for a CD or USB stick.
Change this command as needed for a CD or USB stick.
Change this command as needed for a CD or USB stick.
umount /cdrom

New OS Installation
If CD does not mount automatically, type the following comand and press Enter:
rpm -ivh /mnt/cdrom/VMupdates/RPMS/VMware-esx- drivers-scsi-stex--i386.rpm
If the installation fails due to conflicts, try installing with the --force option.
esxcfg-boot -rg esxcfg-boot -b
If the ESX Server did not install on the SuperTrak EX controller, copy stex.o From /usr/lib/vmware/vmkmod/ To /lib/modules/2.4.xxxxx/kernel/drivers/scsi/
mount /mnt/cdrom




This section explains the information that you can obtain from the SuperTrak BIOS.
When the SuperTrak BIOS loads during bootup, the BIOS displays pertinent information about the RAID logical drives. At this point, press Ctrl-S to enter the SuperBuild Configuration Utility.
The SuperTrak BIOS screen displays the following information:
See Figure 1.

Figure 1. SuperTrak BIOS screen

If the SuperBuild BIOS detects a Critical logical drive, the BIOS reports the condition:
Figure 2. SuperTrak BIOS screen, logical drive critical

See “Chapter 8: Troubleshooting” on page 257 for information about rebuilding a critical logical drive.

If the SuperTrak BIOS detects an Offline logical drive, the BIOS reports the condition and temporarily halts the booting process of the Host PC.
Figure 3. SuperTrak BIOS screen, logical drive offline

See “Chapter 8: Troubleshooting” on page 257 for information about restoring an offline logical drive.

The opening screen of the SuperBuild utility is the Main Menu.
Figure 4. SuperBuild Main Menu
The Main Menu (above) has nine options:

The SuperBuild Configuration utility supports up to two SuperTrak RAID Controller cards installed in the same Host PC. Controller selection enables you to select which of the two SuperTrak controllers the utility accesses.
If you have only one SuperTrak card installed in the Host PC, the SuperTrak is Controller 1, and no selection is necessary.
If you have two SuperTrak cards installed in the Host PC, take the following action to select one of them:
The selected controller (SuperTrak card) displays in the SuperBuild utility.

The SuperBuild utility displays information about the selected SuperTrak EX controller.
The information includes:
Vendor – Promise Technology, Inc.
Model – SuperTrak EX4650, 8650, 8654, EX8658, or EX16650
WWN – World Wide Number of the SuperTrak controller
Memory Type – DDR2 SDRAM
Memory Size – 128 MB, 256 MB, or 512 MB
Single Image Ver – The version number of the image used to update the firmware on the SuperTrak EX controller.*
Firmware Version – The version number of the firmware currently installed on the SuperTrak EX controller.*
BIOS Version – The version number of the BIOS currently installed on the SuperTrak EX controller.*
PCI Func Address – The functional address of the SuperTrak card in the Host PC. Used for advanced diagnostics
* The BIOS and Firmware are upgradable. See “Downloading BIOS and Firmware File” on page 285 and See “Updating the Firmware” on page 129.

Physical drive management includes these functions:
To view physical drives:
The information includes:
ID – The channel number of the SuperTrak controller to which the physical drive is attached
Model Name – The physical drive manufacturer’s model name for the drive
Capacity – Data capacity of the physical drive
Status – OK is normal. Can also show Rebuilding or Dead.
The SuperBuild utility displays information about the physical (disk) drives attached to the SuperTrak controller.
The Physical Drive Information screen displays:
ID – The channel number of the SuperTrak controller to which this physical drive is attached.
Model Name – The drive manufacturer’s model name.
Serial Number – The drive manufacturer’s serial number.
Firmware Version – The drive’s firmware version number.
Drive Interface – SAS or SATA, 3.0 or 1.5 Gb/s
Protocol – ATA/ATAPI protocol level.
Capacity – Data capacity of the physical drive in GB.
Location – Enclosure refers to the Host PC. Slot refers to the channel number of the SuperTrak controller.
Configuration – Disk array number and sequence number, Type of spare drive, or Unconfigured.
Status – OK is normal. Can also show Rebuilding, Stale, or Dead.

Physical drives can develop problems that make them unsuitable for service in a logical drive. These problems are reflected in the physical drive status:
See “Chapter 8: Troubleshooting” on page 257 for corrective action.

Disk array management includes these functions:
The SuperBuild utility displays information about the disk arrays managed by the SuperTrak controller.
The information includes:
ID – The consecutive number of the disk array in the order it was created, beginning with 0.
Disk Array Name – The name you assigned to the disk array.
Capacity – Data capacity of the disk array in GB.
Status – OK is normal. Can also show Rebuilding, Degraded, Critical, or Offline.
To view disk array information:
The Disk Array Management screen displays.
The Disk Array Info and Setting screen displays. The information includes:
Disk Array ID – The consecutive number of the disk array in the order it was created, beginning with 0
Disk Array Name – The name you assigned to the disk array
Capacity (Free) – Total data capacity of the disk array in GB
Capacity (Configurable) – Usable data capacity of the disk array in GB
Number of Physical Drives – Number of physical drives in this disk array
Number of Logical Drives – Number of logical drives in this disk array

Status – OK is normal. Can also show Rebuilding, Degraded, Critical, or Offline.
The following information displays:
ID – The channel number of the SuperTrak controller to which the physical drive is attached
Model Name – The physical drive manufacturer’s model name for the drive
Capacity – Data capacity of the physical drive in GB
Status – OK is normal. Can also show Rebuilding or Dead.
The following information displays:
ID – The consecutive number of the logical drive in the order it was created, beginning with 0
Logical Drive Name – The user-assigned name for the logical drive
Capacity – Data capacity of the logical drive in GB
Status – Shows one of seven logical drive conditions: OK, Critical, Offline, Init, Migration, Synchron, and Rebuild.
The Disk Array Management screen displays.
The Create Disk Array screen displays.
An asterisk (*) appears at the left of each selected physical drive.
The new disk array appears under Disk Array Management. If you have more physical drives available, you can create additional disk arrays following the same procedure.
After you have created your disk arrays, Your next action is to create one or more logical drives. See “Creating a Logical Drive” on page 93.

To change the name of a disk array:
The Disk Array Management screen displays.
The Disk Array Info and Setting screen displays.
See “Chapter 8: Troubleshooting” on page 257.
When you delete a disk array, you delete the logical drives and all of the data on them. Be sure to backup any important data before you delete a disk array!
To delete a disk array:
The Disk Array Management screen displays.
An asterisk (*) appears at the left of the selected disk array.
The selected disk array is removed from the list.

Logical drive management includes these functions:
For an explanation of the logical drive concepts and the choices you can make when you create your logical drive, see “Chapter 7: Technology Background” on page 219.
For information about logical drive problems, see “Chapter 8: Troubleshooting” on page 257.
To view your logical drives:
The Logical Drive Management screen displays the following information:
ID – The consecutive number of the logical drive in the order it was created, beginning with 0
Logical Drive Name – The user-assigned name for the logical drive
Capacity – Data capacity of the logical drive in GB
Status – OK is normal. Can also show Rebuilding, Initializing, Synchronizing, Degraded, Critical, or Offline.
To view logical drive information:
The Logical Drive Management screen displays.
The Logical Drive Info and Setting screen displays. The information includes:
Logical Drive ID – The consecutive number of the logical drive in the order it was created, beginning with 0.

Logical Drive Name – You can change this setting.
Capacity – Data capacity of the logical drive in GB
RAID Level – Chosen when the logical drive was created.
Stripe Size – Chosen when the logical drive was created.
Sector Size – Chosen when the logical drive was created.
Write Cache Policy – You can change this setting.
Read Cache Policy – You can change this setting.
Disk Array ID – Consecutive number of the disk array to which this logical drive belongs
Status – OK is normal. Can also show Rebuilding, Initializing, Synchronizing, Degraded, Critical, or Offline.
You must create a disk array before you can create a logical drive. See “Creating a Disk Array” on page 90.
To create a logical drive:
The Logical Drive Management screen displays.
The Create Logical Drive Step 1/2 screen appears.
An asterisk (*) appears at the left of the selected disk array.
Highlight Next Step and press Enter.
The Create Logical Drive Step 2/2 screen displays.

At this point you can create additional logical drives, if there is space remaining on your disk arrays. To create another logical drive, repeat steps 2 though 5 above.
Do not press the Ctrl-Alt-Del keys. Do not press the Esc key.
Promise recommends that you Initialize your logical drives immediately after you create them. Initialization sets all data bits in the logical drive to zero, removing any residual data left behind from earlier configurations. You can also perform an Initialization on an existing logical drive.
When you initialize a logical drive, you delete all data on the logical drive. Be sure to backup any important data before you initialize a logical drive!
The Logical Drive Management screen displays.
A message appears at the bottom of the screen.

The Initialization begins immediately. If you set Initialization for multiple logical drives, they will be initialized sequentially. You can monitor Initialization progress under Background Activity.
To change logical drive settings:
The Logical Drive Management screen displays.
The Logical Drive Info and Setting screen displays.
The changes happen immediately.
When you delete a logical drive, you delete all data on the logical drive. Be sure to backup any important data before you delete a logical drive!
To delete a logical drive:
The Logical Drive Management screen displays.
An asterisk (*) appears at the left of the selected logical drive.

The selected logical drive is removed from the list.

Spare drive management includes these functions:
To view your spare drives:
ID – The consecutive number of the spare drive in the order it was created, beginning with 0
Model Name – The physical drive manufacturer’s model name
Capacity – Data capacity of the physical drive in GB
Status – OK is normal. Can also show Rebuilding or Dead.
To view spare drive information:
The Spare Drive Management screen displays.
The Spare Drive Info and Setting screen displays. The information includes:
Physical Drive ID – The channel number of the SuperTrak controller to which the physical drive is attached.
Revertible – Yes or No.
Spare Type – Global or Dedicated.
Disk Array – ID, name, capacity, and status, for spare drives dedicated to an array
For a physical drive to qualify as a spare, the drive must be:

To create a spare drive:
The Spare Drive Management screen displays.
The Assign Spare Drive Step 1/2 screen appears.
An asterisk (*) appears at the left of the selected physical drive.
Highlight Next Step and press Enter.
The Assign Spare Drive 2/2 screen displays.
An asterisk (*) appears at the left of the selected disk array.
You can change a spare drive’s revertibility and type. To change spare drive settings:
The Spare Drive Management screen displays.
The Spare Drive Info and Setting screen displays.

An asterisk (*) appears at the left of the selected disk array.
The changes happen immediately.
To delete a spare drive:
The Spare Drive Management screen displays.
An asterisk (*) appears at the left of the selected spare drive.
The selected spare drive is removed from the list.

The Background Activity function enables you to monitor background activities are running on the SuperTrak RAID controller. Information reported includes:
The Background Activity screen does not enable you to start, pause, resume, or cancel any activity. Status of the activity, such as in-progress or paused.
To view background activity, in the Main Menu, highlight Background Activity and press Enter.
When you are done, highlight Return to Previous Menu and press Enter.

The event log tracks events related to the SuperTrak controller and includes the following functions:
RAM events are also called Runtime events. All recorded events happened since the last time you booted the Host PC. Displays the 1023 most recent events.
To view NVRAM events:
The Event Log screen displays.
NVRAM events are the most important events. These events are stored in non- volatile RAM. Displays the 63 most recent events.
To view NVRAM events:
The Event Log screen displays.

Clearing the event logs remove all of the events from both the RAM and NVRAM event logs. Note that the RAM log clears every time you boot the Host PC.
The Event Log screen displays. You can clear both logs from the RAM or NVRAM screen.

The Time Sync function adds two special features to SuperTrak. These functions include:
The Time Sync function does not replace or overwrite the regular date and time settings in the Host PC’s BIOS or OS.
To set the difference between the current time zone (the time zone in which you are) and Greenwich Mean Time (GMT):
The Time Sync screen displays.
Each press of the + key increments 15 minutes forward. Each press of the – key increments 15 minutes backward.
This feature requires you to have installed in the Host PC a separate product that is not part of SuperTrak RAID controller.
To synchronize time with an embedded site:
The Time Sync screen displays.

The Miscellaneous menu enables three useful functions on SuperTrak:
The LEDs for SAS disk drives stay on continuously to show Ready status, except when the drive is processing a command. This function enables you to turn the LEDs off.
To turn the SAS drive LEDs off:
This function enables you to set your SuperTrak card to work your enclosure management controller through the SGPIO connection.
To choose your enclosure management controller setting:
The buzzer sounds to inform you that your RAID system needs attention. But the buzzer does not specify the condition. When a continuous tone sounds, there are multiple alarm patterns sounding at the same time.

When the buzzer sounds, take the following actions:
To silence the buzzer for the current trigger event, you must disable it.
Also see “Chapter 8: Troubleshooting” on page 257.
To enable or disable the Buzzer:



This chapter describes using WebPAM PRO to monitor and manage your RAID system. This chapter is divided into sections for major WebPAM PRO components as shown above.
You can log into WebPAM PRO in either of two ways:
At the Host PC (where the SuperTrak EX Controller is installed), to log into WebPAM PRO, do one of the following actions:

You can log into WebPAM PRO from any PC with a network connection to the Host PC (where the SuperTrak EX Controller is installed).
If you chose External SSL Security during installation (Windows, see page 44; Linux, see page 51), use the Secure Connection. Otherwise, use the Regular Connection.
Together, your entry looks like this:
http://192.168.10.228:8080/promise
Together, your entry looks like this:
https://192.168.10.228:8443/promise

When the opening screen appears:
The User Name and Password are case sensitive. See Figure 1.
Figure 1. The WebPAM PRO login screen

WebPAM PRO is browser-based RAID management software with a graphic user interface. Basic user interface components and functions include:
Figure 2. WebPAM PRO interface


There are four major parts to the WebPAM PRO interface:
The Header contains the following items:
Tree View enables you to navigate around all components of the Host PC (where the SuperTrak controller card is installed), software management, RAID controller, enclosure, physical drives, disk arrays, logical drives, and spare drives. The figure below shows the components of Tree View.

Figure 3. WebPAM PRO Tree View

Host PC, where the SuperTrak card is installed
The Administrative Tools section is different for the Administrator and Super Users than for other users. The remainder of the Tree is the same for all users.
Management View displays information according to the item you choose in Tree View.
Management View—also referred to Management View—provides the actual user interface with the SuperTrak EX Controller card, including creation, maintenance, deletion, and monitoring of disk arrays and logical drives.
Function Tabs control specific actions and processes. This View changes depending on which item you choose in Tree View and which tab you choose in the Management View itself.
Click the Help button to the right of the tabs in Management View to access online help for the function that is currently displayed.
Logged-in User

WebPAM PRO displays in the following languages:
To change the display language:
WebPAM PRO displays in the chosen language.
To view the Event Frame, click Show Event Frame in the Header.
To hide the Event Frame, click Hide Event Frame in the Header.
The Event Frame reports all events and stores them in the WebPAM PRO folder on the hard disk drive of the Host PC.
In the event frame, events are listed and sorted by:

You can also view events by clicking the Subsystems icon in Tree View, then clicking the Event tab in Management View.
This function saves a copy of the events from the Event Frame as a text file on the Host PC’s hard drive.
To save the event log:
The event log is saved as a text file on the Host PC’s hard drive.
This function deletes the events from the Event Frame and from the WebPAM PRO database. Deleting the events from this point does not affect events physically stored in the HBA’s or Subsystem’s RAM or NVRAM.
This function has no effect upon events reported under the Subsystem icon Events tab. See “Viewing the Runtime Event Log” on page 130 and “Viewing the NVRAM Event Log” on page 131.
To clear the event log:
The Storage Network consists of all the subsystems and host PCs currently accessible on your network. Use this function to identify the subsystem or host PC you want to add.
Subsystems and host PCs already added to WebPAM PRO have a + icon beside them in Tree View.

Figure 4. The Storage Network appears in Tree View

Added to WebPAM PRO
To view the Storage Network, click Show Storage Network in the Header. All networked systems will appear in Tree View.
To hide the Storage Network, click Hide Storage Network in the Header. Only the networked systems you have added appear in Tree View.
See “Adding a Subsystem or Host” on page 120.
There are two ways to log out of WebPAM PRO:
Figure 5. Clicking “Logout” in the Header)

Clicking Logout brings you back to the Login Screen. After logging out, you must enter your user name and password in order to log in again.
Not added yet

User Management includes all functions dealing with user accounts. Functions include:
The view a list of users, their status, access privileges, display name, and email address:
The Information tab appears in Management View.
To change settings of other users:
The Settings screen for the chosen user displays.
The Administrator or Super User can change another user’s password. See “Changing a User’s Password” on page 117 for more information.

You can also set user privilege under Subsystem/Host Management. See “Setting User Privilege” on page 122 and “Setting User Rights” on page 127.
To change your own user settings:
To change a user’s password:
The Settings screen for the chosen user displays.
To set or change your own password:
If you do not have a password, leave this field blank.

To create a user:
A password is optional. If you do not assign password, tell this user to leave the password field blank when he/she logs into to WebPAM PRO. Users can set their own passwords, see “Changing Your Own Password” on page 117.
A display name is optional but recommended.
For definitions of each privilege level, see the List of User Privileges below.
There will always be at least one Super User account. You cannot delete the user account you used to log in. To delete a user:


Subsystem/Host Management includes the following functions:
To view the Subsystem/Host List:
In the Information tab, the following information appears:
If a red X appears under Health, click the Health Information icon to display a breakdown showing the health of the controller, disk arrays, logical drives, spare drives, and physical drives.
To add a subsystem/ or host PC to WebPAM PRO:

Choose this option for SuperTrak. Note that entries such as localhost or the Host PC’s network name do not work for this function.
The new Subsystem or Host PC is added to Tree View.
When you delete a subsystem or host PC, you only remove it from WebPAM PRO’s list of monitored systems. This action has no effect upon the disk arrays, logical drives, or data stored on the RAID.
To delete a subsystem or host PC:

To set user privilege:
For definitions of each privilege level, see “List of User Privileges” on page 118.
You can also set user privilege under User settings. See “Making User Settings” on page 116.

Software Services include the following functions:
There are two software services: Web Server and Email. There are no user settings. To view the status of the software services:
The service name, startup type, and current status appear under the Service tab.
To change the Web Server settings:
In the HTTP Port field, type the HTTP port number. The default is 8080.
Check the Enable SSL box.
In the HTTPS Port field, type the HTTPS port number. The default is 8443.

The range is 1 to 1440 minutes. 15 minutes is the default.
Session Time Out refers to the amount of time the connection remains active without any user interaction. After WebPAM PRO reaches the Time Out interval, you must log in again and begin a new session.
After you change the Web Server port number, you must restart the Tomcat server.
In the Start menu, choose Programs > WebPAM PRO > Server > Restart.
sh restartPromiseWebPamPro.sh
The system returns:
(Or a similar message)
To change the Email settings:
cd /opt/Promise/WebPAMPRO/Server

To make Extended SMTP settings:
Uncheck the box to disable ESMTP.
Before you can send a test message, your email service must be set up as described in “Setting up Email Service” on page 124.
To send a test email message:
A new window opens.
WebPAM PRO sends a test email message to the address you specified.
To set the refresh time for the Event Frame:
The choices are 15, 30, 60, and 300 seconds.

The CIM client is part of the WebPAM PRO Utility Server. The Utility Server can be installed on any PC on the network. Only one CIM client and Utility Server installation is required.
The CIM client works with CIM server. The CIM server is part of the WebPAMPRO Agent. The Agent must be installed on every host PC where the HBA RAID controller is installed to enable management over a network.
Under most conditions, there is no need to change CIM settings.
To change settings for the CIM client:
The default name is “cim”.
The default password is “password”.
If you change CIM client settings, you must make matching CIM server settings on ALL Host PCs, otherwise WebPAM PRO will be unable to monitor them.
Be sure you change the CIM server settings on ALL of your Host PCs to match the CIM client settings.
To change settings for the CIM server:

The Host is designated by its IP address:127.0.0.1. Host functions include:
To view Host information, click the 127.0.0.1 icon in Tree View. In the Information tab, the following information appears:
User rights is the same function as user privilege. To set user rights:
For definitions of each privilege level, see “List of User Privileges” on page 118.
You can also set user privilege under User settings. See “Making User Settings” on page 116
Unlike clicking browser’s refresh button, this function calls new information from the RAID controller’s firmware to update the screen. To refresh the screen:

Subsystem functions include:
To view information about a subsystem, click the Subsystem icon in Tree View. Management View displays the subsystem information.
To view information about the Host PC, users, controllers, schedules, activities, physical drives, disk arrays, and logical drives, see “Viewing System Configuration” on page 137.

Use this function to clear the statistical data registers for the controller, physical drives, and logical drives.
To clear statistical data:
An alias is optional. To set an alias for this subsystem or host:
Maximum of 48 characters. Use letters, numbers, one space between words, and underscore.
Use this function to update the firmware and BIOS on the SuperTrak controller card. You must first download the update file and save it to the Host PC. See “Downloading BIOS and Firmware File” on page 285.
To upgrade the firmware and BIOS on the SuperTrak controller card:

When the Flash Image Status shows Flash image completed, the firmware and BIOS have been updated.
The health or status of following items is displayed:
If any item reports other than “OK” click that item in the Tree to investigate the cause of the problem.
Runtime Events lists information about all events recorded since the system was started. Runtime events are stored in RAM on the RAID controller. These events are cleared when you reboot your system.
To view runtime events:
The events are listed from newest at the top of the list to oldest at the bottom.
Each event is marked with a level of severity.

This function saves a copy of the runtime event log as a text file on the Host PC’s hard drive.
To save the runtime event log:
A text file of the event log is saved to the Host PC’s hard drive.
This function clears the events from the runtime event log screen and from the RAM on the RAID controller. This function has no effect upon events reported in the WebPAM PRO Event Frame. “Viewing the Event Frame” on page 113.
To clear the runtime event log:
All events are cleared from the screen and the RAID controller’s RAM.
NVRAM Events lists information about the most recent important or critical events. NVRAM events are stored in non-volatile memory on the RAID controller. This information persists even if you reboot your system.
To view runtime events:
The events are listed from newest at the top of the list to oldest at the bottom.

Each event is marked with a level of severity.
This function saves a copy of the NVRAM event log as a text file on the Host PC’s hard drive.
To save the NVRAM event log:
A text file of the event log is saved to the Host PC’s hard drive.
This function clears the events from the NVRAM event log screen and from the NVRAM on the RAID controller. This function has no effect upon events reported in the WebPAM PRO Event Frame. “Viewing the Event Frame” on page 113.
To clear the NVRAM event log:
All events are cleared from the screen and the RAID controller’s non-volatile RAM.

To view the current background activities:
A list of current background activities appears, including:
To make settings for background activities:
The rates are defined as follows:

To run a background activity from the Background Activities tab:
Media Patrol checks the magnetic media on physical drives. When it finds the specified number of bad blocks, it will trigger PDM. See “Making Background Activity Settings” on page 133 and “Running PDM” on page 135.
You can schedule Media Patrol to run automatically, see “Scheduling an Activity” on page 135.
To run Media Patrol:

Predictive Data Migration (PDM) migrates data from the suspect physical drive to a spare disk drive, similar to Rebuilding. But unlike Rebuilding, PDM acts before the disk drive fails and your Logical Drive goes Critical.
You an also run PDM on a specific disk array, see “Running PDM on a Disk Array” on page 163.
Also see “Predictive Data Migration (PDM)” on page 248.
To run PDM:
The suspect physical drive is the Source. The replacement physical drive is the Target.
To view scheduled activities for this subsystem:
To set a scheduled activity for this subsystem:

For a WEEKLY recurrence pattern, make the following settings:
You can choose from 1 to 7 days.
For a MONTHLY recurrence pattern, make the following settings:
You can choose from 1 to 12 months.
The default is today's date.
The default is today's date.

For monthly schedules, if you choose a higher number than a month has days, the activity will occur in the following month. For example, say you choose day 31. But there are only 30 days in the month of June. Therefore, the June activity will happen on July 1. The next activity will happen on July 31.
To delete a scheduled activity for this subsystem:
To view the configuration of your complete system:
The following information is displayed:


The RAID controller is the heart of the RAID storage system. Management of Controllers includes the following functions:
Controllers information refers to a brief summary about the controller. To view Controller information:
The controllers information appears under the Information tab in Management View. Controllers information includes:
Controller information refers to detailed information about the controller. To view Controller information:
The controller information appears on the Information tab in Management View.

Controller information includes:

Controller information, continued:
Items marked with an asterisk (*) are user adjustable. See “Making Controller Settings” on page 141.
To view controller statistics:
To make Controller settings:
Maximum of 48 characters. Use letters, numbers, one space between words, and underscore. An alias is not required.

For more information, see “Capacity Coercion” on page 238.
For more information, see “Choosing Cache Policy” on page 237.
This is the time interval in which the controller polls all of the components in the enclosure.
The changes take effect immediately.
An Orphan Watermark condition is the result of a disk drive failure during an NVRAM RAID level migration on a disk array. The Clear tab remains grayed out unless this condition is present.
To clear an orphan watermark:
The change takes effect immediately.
The RAID controller’s cache backup battery protects data in the cache for up to 72 hours in the event of a power failure.
To view battery information:

In normal operation, the operational status of the battery shows Fully Charged with a Reserve Capacity of 100%. If the battery is constantly recharging, its reserve capacity drops significantly, or the battery remains discharged, replace the battery. Also see “Viewing Enclosure Information” on page 145.
To silence the buzzer for the current event:
The buzzer goes silent but will sound again for future events.
To make buzzer settings:
Uncheck the box to disable the buzzer.
The changes take effect immediately.
You must enable the buzzer before you can test it. See “Making Buzzer Settings,” above.
To test the buzzer:

The buzzer sounds a continuous tone.
The buzzer goes silent but remains enabled.
This function refers to the buzzer on the SuperTrak RAID controller card.
To view buzzer information:

This function of WebPAM PRO does not apply to the SuperTrak RAID controller card installed in the Host PC, except for one item:
Enclosure information includes:
This information might be useful when contacting Technical Support.
To view Enclosure information:
The Enclosure information appears on the Information tab.
See the following topics:
In addition to the SuperTrak EX Series, WebPAM PRO also supports Promise VTrak RAID Subsystems.
For more information about managing those products with WebPAM PRO, see the online help or refer to the Subsystem’s Product Manual.

Managing Physical Drives deals with the physical disk drives under the SuperTrak RAID controller, including the following functions:
To view a list of physical drives in this enclosure:
The list of physical drives appears in Management View.
Click the PD link to view a specific physical drive. See “Viewing Physical Drive Information” on page 148.
Also see “SAS Connections and ID Numbers” on page 15.
Support for this feature depends on how your system or enclosure was set up. Direct-connect systems with individual LED connections and SGPIO enclosures support individual physical drive LEDs. Other systems or enclosures might or might not support them. See “Appendix D: LED Backplane Connections” on page 291.
To locate a physical drive in the enclosure, click the Locate PDx button. The LED for the carrier holding the physical drive will blink for one minute.

To locate a physical drive in the VTrak JBOD enclosure, click the Locate PDx button. The disk status LED will blink for one minute to identify the carrier holding the physical drive.
Figure 6. VTrak drive carrier LEDs
Global settings apply to all of the physical disk drives installed under the SuperTrak controller. The functions include:
SATA Drives SAS Drives
To make global physical drive settings:
Uncheck any features you want to disable.
The changes take effect immediately.
The functions you enable here depend on whether the physical drives support those functions. See “Viewing Physical Drive Information” on page 148 to determine which functions a particular drive supports.
Disk Status · Power/Activity

To view physical drive information:
Useful information provided here includes:
See “Making Global Physical Drive Settings” on page 147.
To view physical drive statistics:
The only individual physical drive setting is an alias. An alias is optional. To set an alias for a physical drive:

Maximum of 32 characters. Use letters, numbers, one space between words, and underscore.
The Clear tab only appears when one or both conditions are present.
Be sure you have corrected the condition by a physical drive replacement, rebuild operation, etc., first. Then clear the condition.
To clear a Stale or PFA status from a physical drive:
If a physical drive has both a Stale and a PFA condition, click the Submit button once to clear the Stale condition, then click again to clear the PFA condition.

Disk Array Management includes the following functions:
To view the disk arrays in this enclosure plus any expanded or cascaded enclosures:
A list of disk arrays appears in Management View.
Click the DA link to view a specific disk array. See “Viewing Disk Array Information” on page 157.
Support for this feature depends on how your system or enclosure was set up. Direct-connect systems with individual LED connections and SGPIO enclosures support individual physical drive LEDs. Other systems or enclosures might or might not support them. See “Appendix D: LED Backplane Connections” on page 291.
To locate a disk array in the enclosure, click the Locate DAx button. The LEDs for the carriers holding the physical drives used by the disk array will blink for one minute.

To locate a disk array in a VTrak JBOD enclosure, click the Locate DAx button. The disk status LEDs will blink for one minute to identify the carriers holding the physical drives used by the disk array.
Figure 7. VTrak drive carrier LEDs
WebPAM PRO provides three methods of creating a disk array:
Disk Status · Power/Activity

The Disk Array – Automatic Configuration option enables you to create a new disk array following a default set of parameters. One logical drive will be made automatically when you create the disk array. If you have multiple enclosures, multiple disk array/logical drive sets are created. To create a Disk Array using the Automatic function:
The following parameters display:
The new disk array appears in the Disk Array List the Information tab.
If you do NOT accept these parameters, use the Advanced option to create your disk array.

The Disk Array – Express Configuration option enables you to choose the parameters for a new disk array by specifying the characteristics you want. With this method, you can create multiple logical drives at the same time you create your disk array. However, all of the logical drives will be the same.
If you prefer to specific the parameters directly, use the Advanced option to create your disk array.
If you are uncertain about choosing parameters for your disk array, use the Automatic option.
To create a new disk array:
If the box is unchecked, and you have both SATA and SAS drives, different arrays will be created for each type of drive.
Or check the Automatic Update box and updates will occur automatically.
The following parameters display:

If you accept these parameters, proceed to the next step.
If you do NOT accept these parameters, review and modify your choices in the previous steps.
The new disk array appears in the Disk Array List the Information tab.

The Disk Array – Advanced Configuration option enables you to directly specify all parameters for a new disk array. One logical drive will be made automatically when you create the disk array. If you specify less than the total available capacity, you can use the remaining space to create additional logical drives now or at a later time.
If you are uncertain about choosing parameters for your disk array, use the Express or Automatic option to create your disk array.
To create a new disk array:
For more information, see “Media Patrol” on page 248.
For more information, see “Predictive Data Migration (PDM)” on page 248.
You can also double-click them to move them.
Logical Drive Creation enables you to specify logical drives under the new disk array. Enter the information for a logical drive, then click the Update button. If there is free capacity remaining, you can specify another logical drive now or wait until later. You can create up to 32 logical drives per array.
The choice of RAID levels depends the number of physical drives you selected.
See “RAID 50 Axles” on page 227 or “RAID 60 Axles” on page 230.

This value will be the data capacity of the first logical drive in your new disk array. If you specify less than disk array's maximum capacity, the remainder will be available for additional logical drives which you can create later.
64 KB, 128 KB, 256 KB, and 1 MB are available. 64 KB is the default.
512 B, 1 KB, 2 KB, and 4 KB are available. 512 B is the default.
Read Cache, Read Ahead Cache, and No Cache are available. Read Ahead is the default.
Write Back and Write Through are available. Write Back is the default.
None, Quick, and Full are available. None is the default but is not recommended. See “Initialization” on page 239.
A new logical drive is displayed under New Logical Drives.
Repeat the above steps to specify additional logical drives as desired.
The Summary lists the disk array and logical drive information you specified.
To proceed with disk array and logical drive creation, click the Submit button.
The new disk array appears in the Disk Array List the Information tab.
This function does not automatically create a hot spare drive. After the disk array is created, you can create a hot spare drive for it. For more information, see “Creating a Spare Drive” on page 173.

The Disk Arrays–Delete tab enables you to delete existing disk arrays.
If you delete a disk array, you also delete any logical drives that belong to it, along with the data in those logical drives. Back up any important data before deleting a disk array.
To delete a disk array:
The chosen disk array disappears from the Disk Array List the Information tab.
To view Disk Array information:
The disk array information is shown in Management View.

available. However, the logical drive has lost redundancy (fault tolerance). You must determine the cause of the problem and correct it.
To make Disk Array settings:

Maximum of 32 characters. Use letters, numbers, one space between words, and underscore. An alias is optional.
When you create a disk array, you automatically create one logical drive also. If the initial logical drive used less than the full capacity of the disk array, you can create additional logical drives from the same disk array. You can create up to 32 logical drives per array.
To create a logical drive:
Maximum of 32 characters. Use letters, numbers, one space between words, and underscore. An alias is optional.
All RAID levels supported by the disk array appear in the list. See “Choosing a RAID Level” on page 232.
The default value is the available capacity of the disk array. You can use this value or any lesser amount.
The choices are 64 KB, 128 KB, 256 KB, 512 KB, and 1 MB. 64 KB is the default. See “Choosing Stripe Block Size” on page 236.
The choices are 512 B, 1 KB, 2 KB, and 4 KB. 512 B is the default. See “Choosing Sector Size” on page 236.

The choices are Read Cache, Read Ahead, and No Cache. Read Ahead is the default. See “Choosing Cache Policy” on page 237.
The choices are Write Through and Write Back. Write Back is the default. If you chose No Cache under Read Cache, this setting will be Write Through. See “Choosing Cache Policy” on page 237.
The choices are None, Quick and Full. See “Initialization” on page 239.
A new window displays with the disk array information and the proposed logical drives with their parameters.
The new logical drive appears in the Logical Drive List the Information tab.
If you created a fault-tolerant logical drive (any RAID level except RAID 0), the Operational Status of new logical drive will display Synchronizing for several minutes after creation. You can use the logical drive during this period but read/ write performance could be slower than normal.
All data the logical drive will be lost. Back up any valuable data before deleting the logical drive.
To delete a logical drive:

In the confirmation box, type the word confirm in the field provided.
The chosen logical disappears from the Logical Drive List the Information tab.
On SuperTrak, RAID level migration is performed on the disk array but it applies to the logical drives. The action of migrating a disk array means either or both:
For a list of Migration options and other important information, see “RAID Level Migration” on page 240.
To Migrate an existing disk array:
The logical drive changes to reflect your choices.
In the confirmation box, type the word confirm in the field provided.

To set Migration priority, see “Making Background Activity Settings” on page 133.
When you rebuild a disk array, you are actually rebuilding the data on a replacement physical drive.
Normally, a disk array would rebuild itself using a hot disk drive, after going Critical. However, if the Auto Rebuild function is disabled or no spare drives are available, you must initiate the procedure.
To enable Auto Rebuild, see “Making Background Activity Settings” on page 133.
To create a spare drive, see “Creating a Spare Drive” on page 173.
For more information, see “Hot Spare Drive(s)” on page 239.
If a physical drive has failed, identify and replace the drive, then rebuild the disk array as described below:
If there are multiple disk arrays, choose the icon with the yellow !.
This is a remaining functional physical drive in the disk array.
This is the replacement physical drive.
The Disk Array Background Activity tab will show the rebuild the replacement (target) physical drive. Depending the size of the physical disk involved, this process will take some time.
To view more information, click the Rebuild on PDx link.
To set Rebuild priority, see “Making Background Activity Settings” on page 133.

Media Patrol checks the magnetic media on physical drives. When it finds the specified number of bad blocks, it will trigger PDM. See “Making Background Activity Settings” on page 133 and “Running PDM” on page 135.
You can schedule Media Patrol to run automatically, see “Scheduling an Activity” on page 135.
To start Media Patrol:
Predictive Data Migration (PDM) migrates data from the suspect physical drive to a spare physical drive, similar to Rebuilding. But unlike Rebuilding, PDM acts before the disk drive fails and your Logical Drive goes Critical.
See “Predictive Data Migration (PDM)” on page 248.
To start PDM:
The suspect physical drive is the Source. The replacement physical drive is the Target.

Transition is the process of replacing a revertible spare drive that is currently part of a disk array with an unconfigured physical drive or a non-revertible spare. The revertible spare drive returns to its original status. For more information, see “Transition” on page 249.
In order to run the Transition function:
To run Transition:
After Transition is completed, refresh the screen. The revertible spare drive will be listed under the Spare Drives icon and the disk array’s operational status will show OK.
To set Transition priority, see “Making Background Activity Settings” on page 133.
Before you can use this feature:
To prepare a disk array for transport:

The drives appear in their new locations and disk array status displays OK.

Logical drives are made from disk arrays. In the Tree, you can see a graphic representation of the logical drives that belong to each array. You can see a summary of all logical drives in the subsystem under Logical Drive Summary.
Logical drive management includes the following functions:
To view information about all logical drives in a disk array:

fault tolerance. When a logical drive is rebuilding, it will function and your data is available. However, access will be slower due to the rebuilding operation.
To create a logical drive, see “Creating a Logical Drive” on page 159.
To delete a logical drive, see “Deleting a Logical Drive” on page 160.
For a Degraded or Offline logical drive, see “Critical & Offline Logical Drives” on page 253.
Support for this feature depends on how your system or enclosure was set up. Direct-connect systems with individual LED connections and SGPIO enclosures support individual physical drive LEDs. Other systems or enclosures might or might not support them. See “Appendix D: LED Backplane Connections” on page 291.
To locate a logical drive in the enclosure, click the Locate LDx button. The LEDs for the carriers holding the physical drives used by the logical drive will blink for one minute.
To locate a logical drive in the VTrak JBOD enclosure, click the Locate LDx button. The disk status LEDs will blink for one minute to identify the carriers holding the physical drives used by the logical drive.
Figure 8. VTrak drive carrier LEDs
To view information for a single logical drive:
Disk Status · Power/Activity

To specify an Alias or set the Read and Write Policies, click the Settings tab.
See “Logical Drive Status” on page 166.
Synchronization is an automatic procedure applied to logical drives when they are created. Yes means the logical drive was synchronized.
See “Changing Logical Drive Settings” on page 168.
To view information for a single logical drive:
To make logical drive settings:

Maximum of 32 characters. Use letters, numbers, one space between words, and underscore. An alias is optional.
The choices are Read Cache, Read Ahead, and No Cache. See “Choosing Cache Policy” on page 237.
The choices are Write Back and Write Through. If you chose No Read Cache, Write policy is automatically Write Through. See “Choosing Cache Policy” on page 237.
Initialization sets the data bits in the logical drive to zero. The action removes any residual data left behind from earlier configurations. Initialization is recommended for new logical drives. You can also initialize an existing logical drive. See “Initialization” on page 239 for more information.
When you initialize a logical drive, all the data the logical drive will be lost. Backup any important data before you initialize a logical drive.
To initialize a logical drive:

To view the progress of the Initialization, click the Background Activity tab.
To set Initialization priority, see “Making Background Activity Settings” on page 133.
You can also start Initialization from the Subsystem icon, Background Activities tab.
Redundancy Check is a routine maintenance procedure for fault-tolerant disk arrays (those with redundancy) that ensures all the data matches exactly. Redundancy Check can also correct inconsistencies. You can also schedule a Redundancy Check. See “Scheduling an Activity” on page 135.
Redundancy Check a Logical Drive:
This feature attempts to repair the problem when it finds an error.
This feature stops the process when it finds an error.
If Auto Fix is also checked, the process stops only when it finds a non- repairable error.
To view the progress of the Redundancy Check, click the Background Activity tab.
To set Redundancy Check priority, see “Making Background Activity Settings” on page 133.
You can also start Redundancy check from the Subsystem icon Background Activities tab
The Logical Drive Check Table displays errors related to a logical drive. Use this information to evaluate the integrity of the logical drive and to determine whether corrective action is needed. To View the tables:

The default is All tables.
If there are entries, they are listed as follows:

When a physical drive in a disk array fails and a spare drive of adequate capacity is available, the disk array will begin to rebuild automatically using the spare drive. See “Critical & Offline Logical Drives” on page 253.
Spare drive management includes the following functions:
To view a list of spare drives:
The information includes:

To create a spare drive:
You can also double-click drives to move them.
You can also double-click arrays to move them.
Your choices are displayed under New Hot Spare Drives.

If an existing spare drive has the wrong parameters for your needs, click the Settings tab to change the parameters rather than delete the spare drive and create a new one.
To delete a spare drive:
In the confirmation box, type the word confirm in the field provided.
The Spare Drive–Settings tab enables you to change the settings of an existing spare drive. To change spare drive settings:
You can also double-click array to move it.

Spare Check verifies the operational status of your spare drives. You can also schedule a Spare Check. See “Scheduling an Activity” on page 135.
To check a spare drive:
Or choose All to check all the spare drives at the same time.
The results of the Spare Check appear under Spare Check Status in the Information tab. “Healthy” means normal condition.

The Logical Drive Summary displays a list of all logical drives under the SuperTrak controller including logical drives in expanded or cascaded enclosures. This list does not arrange the logical drives under the disk array to which they belong nor under the enclosure in which they are located.
Logical Drive Summary includes the following functions:
To view a list of all logical drives in all enclosures:
Support for this feature depends on how your system or enclosure was set up. Direct-connect systems with individual LED connections and SGPIO enclosures support individual physical drive LEDs. Other systems or enclosures might or might not support them. See “Appendix D: LED Backplane Connections” on page 291.
To locate a logical drive in the enclosure, click the Locate LDx button. The LEDs for the carriers holding the physical drives used by the logical drive will blink for one minute.
To locate a logical drive in the VTrak JBOD enclosure, click the Locate LDx button. The disk status LEDs will blink for one minute to identify the carriers holding the physical drives used by the logical drive.
Figure 9. VTrak drive carrier LEDs
Disk Status · Power/Activity

The information and location for the logical drive appear in Management View. See Viewing Logical Drive Information (page 167).



SuperTrak EX Controller’s Command Line Interface (CLI) provides rapid setup of disk arrays and logical drives. You can also manage your SuperTrak system using the CLI. However, ongoing management is much easier with the SuperBuild utility or WebPAM PRO.
To open the CLI, click the CLI icon on the desktop (right), or:
The CLI window opens.


To open the CLI:
The CLI runs in the terminal window.


about View utility information.
array View or edit array information.
Create, edit, or delete a new or existing array.
Create, edit, or delete logical drives in an existing array.
To physically locate an array in an enclosure.
Accept an incomplete array condition.
battery Subsystems only. View battery information or to recondition a battery.
bbm View or clear the BBM defect list of the specified configured physical drive.
bga View status of all current background activities.
Enable or disable relevant background activities.
Modify the background task rate for each of the background tasks.
buzz View buzzer status, enable/disable and turn on/off buzzer.
checktable View logical drive error tables.
config For express or automatic configuration.
For advanced configuration please see the 'array' command.
ctrl View or edit controller information and settings.
date View or edit system time.
enclosure View or edit enclosure and SEP information and settings.
Locate an enclosure via LEDs.
event View or clear events logs.
export Subsystems only. Export files to remote tftp host.
factorydefaults Restore settings to factory defaults.
init View logical drive initialization status and progress.
Start, stop, pause, or resume an initialization or a quick initialization.
Command Action

logdrv View or edit logical drive information and settings.
Locate a logical drive via LEDs.
migrate Start and monitor disk array migration process.
mp View media patrol status and progress.
Start, stop, pause, or resume media patrol.
pdm View PDM status and progress.
Start, stop, pause, or resume PDM process.
phydrv View or edit physical drive information and settings.
Locate a physical drive via LEDs.
ptiflash Update system software and firmware through local host.
rc View redundancy check status and progress.
Start, stop, pause or resume redundancy check.
rb View rebuild status and progress.
Start, stop, pause, or resume a rebuild process.
sc View spare check status. Start spare check.
spare Create or modify hot spare drives.
spath Discover and change subsystem path.
stats View or reset statistics.
subsys View or edit subsystem information and settings.
sync View logical drive synchronization status and progress.
topology View SAS topology, the physical connections and device information. For products that support multiple enclosures only.
transit View transition status and progress.
Start, stop, pause, or resume a transition process.
help When used alone will display this menu.
When used in conjunction with a command (example: help array) it will display help information for that particular command.
Command Action

? This can be used in place of the help command or optionally can be used as a switch for a command (example: array -?) to provide command usage.
Commands and options are NOT case sensitive.
Not all extended keys are supported. However, you can use the backspace and the left and right arrow keys for command line editing. In addition, the up and down arrow keys allow scrolling through the command history buffer.
If you need context-sensitive help, type one of the following commands:
That action will display full context-sensitive help for the specific command.
Each command when used alone, such as “array” will display a summary of relevant information. If more information is desired, the -v verbose mode can be used. This will provide information for all relevant aspects of that command.
Usage terminology is as follows:
Command Action

Summary
Displays utility information.
array [-a ] [-d ] [-c ] [-v] array -a add [-s ""] [-d ] -p [-c ] [-l ""] array -a mod -d [-s ""]
array -a del -d
array -a locate -d
array -a accept -d [-t ]
array -a addld -d [-c ] -l ""
array -a delld -l
array -a transport -d
about

The array command is the main command for performing advanced configuration and maintenance tasks on disk arrays.
This command lists, creates, modifies, deletes, and locates disk arrays. It also adds and deletes logical drives.
-a Specifies the action to perform.
list (Default) Displays a summary of all arrays, a specified number of arrays, or a specific array.
add Adds/creates an array. This action might also create logical drives at the same time.
addld Adds/creates a logical drive to an existing array.
delld Deletes a logical drive from an array.
mod Modifies array settings.
del Deletes an array and all its associated logical drives.
locate Locates an array.
accept Accepts the condition of an incomplete array. Currently, there are two conditions that can cause an array to be incomplete:
When the either of the above conditions occurs, all the logical drives on the array go offline.
You can accept the array in incomplete condition and try to bring the logical drives online. However, that is a high- risk and non-revertible operation, and it may result in data loss. Therefore, it is recommended to clear the condition first, for example: putting the missing drives back or roaming the array back to the original controller and wait until the migration completes.
transport Takes the array and the logical drives on the array offline to get ready for transport the array to another subsystem.
-d The disk array ID. Valid values are 0-255. Specifies the desired array ID when creating (add) an array. Specifies the array ID when listing array information, modifying,

deleting, locating, accepting, adding or deleting a logical drive. Only one array may be specified.
-p Specifies physical drives to be used in an array, with -a add option. PD IDs are specified individually or separated by comma. Sequential group of physical drives are specified by placing a ~ between numbers such as 1~6. This will include physical drives 1, 2, 3, 4, 5, and 6.
-s "= Specifies array settings when creating (add) or modifying (mod) an array. Options are comma separated.
alias= A user-specified array name. Up to 32 characters, alpha- numeric characters, blank spaces and underscores. Beginning and ending blank spaces are discarded.
mediapatrol= Enables or disables Media Patrol for this array.
enable The default is enable.
pdm= Enables or disables PDM for this array.
enable The default is enable.
-l "=" Specifies logical drive settings when adding a logical drive to an existing array (addld) or during array creation (add). Options are comma separated.
Specifies a list of Logical Drive IDs. Requires the -a delld option.
ID= Assigns a specific ID to an array. Overrides automatic ID assignment. Valid values are 0-255.
Alias= A user-specified name for the logical drive.
Raid= Specifies logical drive RAID level.
0 Striping.
1 Mirroring on two drives.
5 Parity, requiring 3 or more drives.
10 Mirroring on even number of drives.
1e Extended mirroring, requiring 2 or more drives.
50 Striping on multiple RAID 5, requiring 6 or more drives.
6 Allow two drive failure, requiring 4 or more drives.
60 Striping on multiple RAID 6, requiring 8 or more drives.
Capacity= Specifies logical drive capacity. Can be specified in megabytes (mb), gigabytes (gb) or terabytes (tb), up to 2
disable · disable

decimal places. If not specified, all available capacity is used for this logical drive.
Stripe= Specifies logical drive stripe size. Options include 64KB, 128 KB, 256 KB, 512 KB, and 1024 KB. If not specified, the default 64KB is used.
Sector= Specifies logical drive sector size. Options include 512 B, 1 KB, 2 KB, and 4 KB. Sector size cannot exceed Stripe size. Auto-adjusted not to exceed the maximum supported sector size of the controller. See controller information on page 194. If not specified, the default 512 B is used.
WritePolicy= Specifies logical drive write policy.
writethru Writes are not cached
writeback Writes are cached
ReadPolicy= Specifies logical drive read policy.
readahead Reads extra data to help reduce read times of sequential data.
readcache Caches reads the data in case the same request is made again.
nocache No caching algorithm.
Axle= A member element when creating a RAID10 or RAID50 or RAID60. RAID10 have 2 axles, RAID50 and RAID60 may have up to 16 axles with up to 16 drives per axle.
PreferredCtrlId= Subsystems only. Specifies which controller the LD is preferred for LUN affinity. Valid value is 1 or 2. If value is not specified, LUN affinity is auto balanced.
-c Specifies the number of arrays to give a summary of when used with the -a list option. For example 'array -a list -c3' will give a summary for the first 3 arrays on that controller.
Specifies the number of logical drives to be created with the -a add option. With the -c option, all the logical drives have same settings but only one -l option=value can be specified.
-t Specifies the type of incomplete condition to accept. If not specified, it will accept the current incomplete condition by default.
missingdrive The condition of missing drive in the array.
missingwatermark The condition of missing NVRAM watermark of the array.
-v Verbose mode. Displays all array properties, requires -a list option.

array -v -c 1
array -a add -s "alias=MyArray,mediapatrol=enable" -p 1,3,5~9
array -a add -p 1,3,5~9 -l "raid=5,capacity=50gb,stripe=256kb"
array -a mod -d 1 -s "alias=YourArray,mediapatrol=disable"
array -a del -d 3
array -a locate -d 0
array -a accept -d 2
array -a addld -d 0 -l "raid=1e,capacity=125gb,stripe=64kb"
array -a delld -l 1
battery [-a ] [-b ]
battery -a recondition -b
The battery command displays the status of a battery by the percentage of charge left.
On subsystems, this command also reconditions the battery. Reconditioning fully discharges then fully recharge the battery. The battery is reconditioned automatically once per month.
-a Specifies the action to perform.
list (Default) List information for all batteries or a specific battery.
recondition Subsystems only. Recondition a specific battery.
-b Specifies which battery in a given enclosure.
battery -a recondition -b 1
-l "raid=5,capacity=50gb,stripe=256kb,sector=1kb" · -l "raid=0,capacity=100gb" · battery

bbm [-a ] [-p ]
bbm -a clear -p
The bbm command displays and clears the Bad Block Map (BBM) for all configured SATA drives.
-a Specifies the action to perform.
list (Default) List the BBM information.
clear Clears the BBM list. For configured SATA drives only.
-p Specifies the physical drive id. For the -a list option, the default is all physical drives. For the -a clear option, you must specify a physical drive id.
bbm -a clear -p 3
bga -a mod -s ""
The bga command displays all current background activities and makes settings each background activity.
-a Specifies the action to perform.
list (Default) Lists current background activities.
mod Makes changes to one of the settings.
-s "=" Specifies which background activity settings to change.
autorebuild= Enable or disables auto-rebuild and auto-transition.
Auto-rebuild will rebuild an array when an unconfigured drive is inserted into the slot of a dead drive.
bbm -p 1 · bga [-a ]

Auto-transition will start transitioning on a used revertible spare in the following condition:
When a non-revertible spare has been inserted or created, and is applicable to the array.
This option affects all arrays on the subsystem.
mediapatrol= Verifies the media of the array and/or spares to find bad blocks on physical disks before you use that block. This feature is enabled and disabled on an array basis.
ReassignedBlock=Threshold value to trigger PDM, when re-assign map
exceeds the threshold value
ErrorBlock= Threshold value to trigger PDM, when number of medium error on the PD exceeds the threshold value.
1..2048
= Background task rates determine what percentage of the IO load on the controller should be dedicated to the background task. A lower number will mean the task takes longer to complete, a higher number will cause the task to complete faster, all other things being equal.
rebuildrate= Rebuild rate determines the rate at which rebuild will run. (low=25, medium=50, high=75)
pdmrate= PDM rate determines the rate at which PDM will run. (low=25, medium=50, high=75)

transitionrate= Transition rate determines the rate at which transition will run. (low=25, medium=50, high=75)
syncrate= Synchronization rate determines the rate at which synchronization will run. (low=25, medium=50, high=75)
initrate= Initialization rate determines the rate at which initialization will run. (low=25, medium=50, high=75)
rcrate= Redundancy check rate determines the rate at which redundancy check will run. (low=25, medium=50, high=75)
migrationrate= Migration rate determines the rate at which migration will run. (low=25, medium=50, high=75)
bga -a mod -s "autorebuild=enable,rebuildrate=high,syncrate=low"

The buzz command displays the status of the buzzer, and enables, disables, turns on or turns off the buzzer.
-a Specifies the action to perform.
list (Default) List the status of the buzzer.
enable Enable the buzzer.
disable Disable the buzzer.
on Turn on the buzzer.
off Turn off the buzzer.
checktable [-t ] -l
The checktable command displays the error check tables of a logical drive.
-t Specifies which error table to display. The default displays all tables.
rct Displays the read check table.
wct Displays the write check table.
ibt Displays the inconsistent block table.
-l Specifies the logical drive ID.
checktable -l 10 -t rct
config -a expr [-r y|n] [-c y|n] [-p y|n] [-m y|n] [-s y|n] [-t ] [-l ]

The config command has two options: Automatic and Express.
Automatic configuration takes all available unconfigured physical drives to create an optimized disk array following a default set of parameters. There are no options.
Express configuration takes your input, creates one or two arrays, and spreads their capacity evenly over all of the logical drives that you specify.
The redundancy option creates redundant logical drives (RAID 1, 10, 1E, 5, 50, 6, or 60).
The capacity option enables optimizes the logical drives for capacity.
The performance option optimizes the logical drives for performance.
If you choose all three options, redundancy gets highest priority and capacity gets lowest priority.
-a Specifies the action to perform.
auto Automatic configuration with no options. Creates an optimized disk array. One or more logical drives are created automatically.
expr Express configuration. RAID level is dependant on the options chosen.
-r Selects the redundancy option.
-p Selects the performance option.
-c Selects the capacity option.
-m Allows mixing SATA and SAS physical drives in the same array.
-s Includes a spare drive in the array. Note: Requires 5 or more unconfigured physical drives.
-t Specifies the intended application for this array.
video Sequential large block reads.
data Random read/write mix, small to medium sized IO.
log Sequential small block write.
other Random read/write mix, small to medium sized IO.
fileserver Random read/write mix, small to medium sized IO.
-l Specifies how many logical drives to include in the configuration. Array capacity is divided evenly among the logical drives.

config -a expr -ry -p y -c n -sy -t data -l2
ctrl [-a ] [-i ] [-c ] [-v]
ctrl -a mod [-i ] -s ""
ctrl -a clear [-i ] [-t ]
The ctrl command displays controller information and changes controller settings.
-a Specifies the action to perform.
list (Default) Lists controller information.
mod Changes controller settings.
clear Clears controller conditions.
-i Specifies the controller ID. For subsystems with dual controllers, controller ID is required when setting alias of controller.
-c Controller count. Required for information on multiple controllers.
-s "=" Specifies which settings to change.
alias= A user-specified name for the controller.
Up to 48 characters long, alpha- numeric characters, blank spaces and underscores. The beginning and ending blank spaces are discarded.
Following setting is shared if there are dual controllers:
coercion= Enables or disables disk coercion. Disk coercion will truncate the size of the physical drives. Makes different size drives appear to be the same size. For example, a 90.1 GB drive would appear as the same size as an 89.8 GB drive. Important when using drives of different manufacturers for rebuilds or as hot spares.
coercionmethod= The method of coercion.
config -a auto · enable · disable

GBTruncate Truncates the drive to the nearest 1-billion byte boundary.
10GBTruncate Truncates the drive to the nearest 10-billion byte boundary.
GrpRounding Truncates the drive using an intelligent algorithm. Allows the maximum amount of usable space.
TableRounding Truncates the drive using a pre-defined coercion table.
smart= Enables or disables polling drive SMART status.
smartpollinginterval= Sets the time interval in number of minutes to poll the drive SMART status.
1..1440
cacheflushinterval= Sets the time interval in seconds to flush the controller writeback cache.
migrationstorage= Sets location to store the migration watermark.
ddf Uses the DDF area on the physical drives of the disk array.
nvram Uses the NVRAM on the controller.
lunaffinity= Subsystems only. Enables or disables LUN affinity, allowing LD access only to certain controller. For subsystems with dual controllers.
pollinterval= Sets interval in seconds to poll enclosure SEP information.
15..255
lunmapping= Subsystems only. Chooses WWN based or Slot based LUN mapping method.
adaptivewbcache= Enables or disables adaptive writeback cache.
enable Writeback logical drives will change the write policy based on the availability of protection. If BBU or UPS is available, the write policy is retained as Writeback, otherwise the policy is switched to Writethru.

disable The write policy of the writeback logical drives are not changed irrespective of the availability of BBU or UPS.
hostcacheflushing= Subsystems only. To enable or disable host cache flushing. When enabled, SYNCHRONIZE CACHE SCSI command from host is supported.
For high availability products only.
forcedreadahead=Enables or disables forced read ahead caching.
commonwwnn= Enables or disables common WWNN. For subsystems with dual controllers.
enable All controllers report one common WWNN.
disable Each controller reports its own WWNN.
alua= Subsystems only. Enables or disables asymmetric logical unit access. Enabling ALUA will enable LUN affinity automatically.
-t Specifies the type of condition to clear. Valid only when the command action is "clear".
watermark Watermark, the only supported condition for now. Used with the -a clear option to clear an orphan migration watermark in the controller NVRAM. This action only works when migration storage is set to NVRAM prior to starting migration.
-l Displays the id of the controller on whose serial port the CLI is running.
-v Verbose mode. Used with the -a list option.
ctrl -a mod -i 1 -s "alias=ctrl1, coercion=enable"

date -a mod [-d ] [-t ]
The date command displays the system time and date, and changes these settings.
-a Specifies the action to perform.
list (Default) Displays the current system time.
mod Modifies the current system time. Not supported for HBA products.
-d Specifies the date in the following format: yyyy/mm/dd where month's range is 1-12 and day's range is 1-31.
-t Specifies the time in the following format: hh:mm:ss where hour range is 0-23, minute and second range is 0-59.
date -a mod -d 2004/02/25 -t 14:50:05
enclosure [-a ] -v
enclosure -a mod -s
enclosure -a locate [-t -f ]
The enclosure command provides status and information about the various components of the enclosure unit. It is also sets temperature threshold values and displays Vendor Provided Data (VPD).
-a Specifies the action to perform.
list (Default) Displays information and status of the enclosure.
date · date

mod Modifies settings. Requires the -s option.
locate Locates an enclosure by flashing its LEDs.
-e Enclosure ID. The default value is 1 if unspecified. For list action, the default is for all enclosures if unspecified.
-s "=" Specifies the settings to change.
tempwarning= Enclosure warning theshold temperature, in degrees Celsius.
tempcritical= Enclosure critical theshold temperature, in degrees Celsius.
ctrltempwarning= Controller warning theshold temperature, in degrees
Celsius.
ctrltempcritical= Controller critical threshold temperature, in degrees Celsius.
-t Specifies which type of FRU to locate. Requires -a locate option.
ctrl Locates the controller.
cooling Locates the cooling unit. Only works with SAS type enclosure.
psu Locates the power supply unit. Only works with SAS type enclosure.
-f Specifies id of FRU to locate. Requires -a locate option. Valid values are 1 and 2.
-v Verbose mode. Requires -a list option. VPD information is displayed.
enclosure -a mod -s "tempwarning=40,tempcritical=55"
event [-a ] [-l ] [-i ] [-c ] [-v]
enclosure · enclosure -v

event -a clear [-l ]
The event command displays and clears the RAM and NVRAM event logs.
-a Specified the action to perform.
list Displays the events for the specified location. RAM events are displayed if no location is specified.
clear Clear events for a specified location.
-l Specifies the location from which to display or clear events.
ram All events are stored in RAM. These events are lost after rebooting.
nvram Some events are also stored in NVRAM. These events remain after rebooting and are a subset of the RAM events.
-i Specifies a specific event by its sequence number. This is a starting point. Requires the -a list option. You can use the -c option.
-c Specifies the number of events to retrieve when displaying events.
-v Verbose mode. Requires the -a list option.
event -a clear -lnvram
event -a list -i852 -c200
export -t [-s ] [-p ] -f
The export command exports certain types of configuration files to a remote or local host.
This command only affects subsystems.

-t Specifies the type of file to export.
userdb User database file. This file type is not applicable for in- band and can only be exported to a remote host.
servicereport System service report file. This file is exported to remote host for embedded and local host for in-band.
-f Specifies the name of the file to be exported.
-s Specifies TFTP server’s IP or host name. Do not specify TFTP server for in-band.
-p The port number of the TFTP server. Default is 69. Do not specify port number for in-band.
export -t userdb -s 192.168.1.1 -f userdb.bin
export -t servicereport -s 192.168.1.1 -f servicereport # for embedded
export -t servicereport -f servicereport # for in-band
factorydefaults -a -t
The factorydefaults command restores factory default settings.
-a Specifies the action to perform.
restore Restore the factory default settings.
-t Specifies the type of settings to restore.
all All settings.
allfw All firmware settings.
allsw Subsystems only. All software settings.
Following are individual Firmware settings:
bga Background activity settings.
ctrl Controller settings.
encl Enclosure settings, including temperature thresholds, buzzer etc.
fc Subsystems only. FC port settings.

iscsi Subsystems only. iscsi settings, including node, port, SLP, and iSNS.
netiscsi Subsystems only. Network settings of iSCSI ports.
netmgmt Subsystems only. Network settings of management ports.
phydrv Physical drive settings.
sas Subsystems only. SAS host interface port setting.
scsi Subsystems only. Parallel SCSI channel settings.
subsys Subsystem settings.
Following are individual Software settings, which only apply to Subsystems:
bgascheduler Background activity scheduler settings.
service Service startup type settings.
webserver Web server settings.
snmp SNMP settings.
telnet Telnet settings.
email Email settings.
netsend Netsend settings.
cim CIM settings.
user User settings.
factorydefaults -a restore -t phydrv
factorydefaults -a restore -t all
init [-a ] [-l ]
init -a start -l [-q ] [-p ]
init -a stop -l
init -a pause -l
init -a resume -l
The init command starts, stops, pauses, and resumes a logical drive initialization.
A full initialization writes to the entire logical drive space and takes several minutes, depending on the size of the logical drive.

A quick initialization writes to the first and last few megabytes of the logical drive. Typically, a quick initialization is completed in moments.
-a Specifies the action to perform.
list Displays a list of the initializations in progress or paused and their status. The default action.
start Start an initialization.
stop Stop an initialization.
pause Pause an initialization.
resume Resume an initialization.
-l Specifies the logical drive to be initialized.
-q Specifies the amount of data in megabytes (MB) for a quick initialization.
1..1024
-p Specifies the pattern for a full initialization. The pattern can range from 1 to 128 bytes (HEX string), and is padded to even number of bytes, such as, fff padded to 0fff.
Pattern is not supported for quick initialization.
init -a stop -l0
init -a start -l0 -p5a5a0101
logdrv [-a ] [-l ] [-c ] [-v]
logdrv -a locate -l
logdrv -a mod -l -s ""
The logdrv command displays information about the logical drives and changes logical drive settings.
To create a logical drive, see the array command on page 184.
-a Specifies the action to perform.
init

list (Default) Displays a summary of one or more logical drives.
mod Changes logical drive settings.
locate Locates a logical drive within the enclosure by flashing drive carrier LEDs.
-l [] Logical drive ID.
-c [] Logical drive count. Requires the -a list option.
-s ["="]Specifies the logical drive settings to change.
alias= A user-specified name for the logical drive. Up to 32 characters, containing alpha-numeric characters, blank spaces and underscores. Beginning and ending blank spaces are discarded.
WritePolicy= Specifies logical drive write policy.
writethru Writes are not cached.
ReadPolicy= Specifies logical drive read policy.
readahead Reads extra data to help reduce read times of sequential data.
readcache Caches reads in the case the same request is made again.
nocache No caching algorithm.
PreferredCtrlId= Specifies which controller the LD is prefers for LUN affinity. Valid value is 1 or 2.
-v Verbose mode. Used with -a list.
logdrv -a mod -l0 -s "readpolicy=readahead"
logdrv -a locate -l2
migrate [-a ] [-d ]
migrate -a start -d -p -l
logdrv · logdrv -v

The migrate command expands the capacity of a logical drives (online capacity expansion) and changes logical drive RAID levels (RAID level migration).
-a Specifies the action to perform.
list (Default) Displays the migration status of specified disk array. If no array ID specified, all migration statuses are displayed.
start Starts the migration.
-d Specifies the ID of the array to be migrated.
-p Specifies the physical drives to be added to the array.
-l "=" Specifies logical drive migration settings.
id= (Required) Specifies the logical drive ID.
capacity= Specifies the new logical drive capacity. Specify a value only when expanding logical drive capacity.
raid= Specifies the new RAID level. Note: When expanding a RAID 10 logical drive, specify RAID 10 as the target RAID level, otherwise the resulting logical drive is a RAID 1E.
axle= Specifies the axle number. Applies to RAID 50 and 60 when the RAID Level is changed.
stripe= Specifies the new stripe size. Not currently supported.
migrate -a start -d 1 -p 10 -l "id=0,capacity=10gb"
Summary
The mp command activates Media Patrol. Media Patrol searches the physical drives for media errors. When an error is found, Media Patrol attempts to repair the error. If it fails to correct the error, Media Patrol attempts to remap the sector. Note: Sector remapping is not currently supported.
migrate -d 1 · mp -a

You can start, stop, pause, or resume Media Patrol and monitor its progress and status.
-a Specifies the action to perform.
list (Default) Displays the status and progress of Media Patrol.
start Starts Media Patrol.
stop Stops Media Patrol.
pause Pauses Media Patrol.
resume Resumes a paused Media Patrol.
pdm
Usage
pdm [-a ] [-d ] [-s ]
pdm -a start -d -s -p
pdm -a stop -d -s
pdm -a pause -d -s
pdm -a resume -d -s
The pdm command activates Predictive Data Migration (PDM). PDM replaces a suspect physical drive, such as a drive with a PFA condition, with a different drive. The replacement drive can be an unconfigured drive, a global spare, or a dedicated spare to this disk array.
During PDM, the data on the suspect drive is transferred to the replacement drive while the logical drive remains online.
After PDM, the replacement drive becomes part of the disk array. The suspect drive become unconfigured and any PFA condition remains on it.
This command starts, stops, pauses, and resumes a PDM and monitors the progress of a running PDM.
A PFA drive cannot be used until you clear the PFA condition. To clear the PFA conditon of a physical drive, please refer to phydrv command on page 206.
mp · mp -a stop · mp -a resume

-a Specifies the action to perform.
list (Default) Displays the active and paused PDMs and their status.
start Starts a manual PDM.
stop Stops a PDM.
pause Pauses a PDM.
resume Resumes a paused PDM.
-d Specifies which disk array on which to perform the PDM.
-s Specifies the sequence number of the suspect drive.
-p Specifies physical drive ID of the replacement drive.
pdm -a start -d0 -s2 -p10
pdm -a stop -d0 -s2
phydrv [-a ] [-p ] [-c ] [-v]
phydrv -a mod -p -s ""
phydrv -a locate -p
phydrv -a online -p
phydrv -a offline -p
phydrv -a clear -t -p
The phydrv command displays physical drive information, changes physical drive settings, locates individual drives, and forces a drive to an online or offline state.
-a Specifies the action to perform.
list (Default) Displays all physical drives, their make, model number, and array they belong to. Their status is also shown.
mod Modifiies physical drive settings.
locate Flashes the physical drive's LED so you can location it.
pdm

online Forces a drive from an Offline to an Online state. Caution: Do this action only in extreme conditions. It causes data corruption in most cases.
offline Forces a drive from an Onine to an Offline state.
clear Clears a drive's condition.
-p Specifies the physical drive ID.
-c Specifies number of drives when their ID numbers are sequential.
-t Specifies type of condition to clear. Requires the -a clear option.
pfa Clears a PFA condition on the drive.
staleconfig Clears a stale configuration on the drive.
-d Specifies type of settings to modify. Requires the -a mod option. Defaults to be all if -d is not specified.
sata SATA related setting(s): writecache, rlacache, and cmdqueuing. The SATA settings apply to all SATA physical drives.
sas SAS related setting(s): writecache, rlacache, readcache. The SAS settings apply to all SAS physical drives.
all Apply to both SATA and SAS drives where is applicable.
-s "=" Specifies which settings to change.
alias= User-specified name, only for configured physical drives. Up to 32 characters, containing alpha- numeric characters, blank spaces and underscores. Beginning and ending blank spaces are discarded.
The following global settings are for physical drives that support these features:
writecache= Enables or disables write cache on the physical drive(s).
rlacache= Enables or disables read look ahead cache on the physical drive(s).
cmdqueuing= Enables or disables command queuing on the physical drive(s).

temppollint=Drive temperature polling interval in seconds. If value is 0,
polling is disabled. For subsystems with dual controllers.
15..255
Medium error threshold. If the threshold is reached, the physical drive is marked as dead. The default value is 0, indicating that physical drive is not marked as dead for medium errors. For subsystems with dual controllers.
0..4294967294
The following settings are only for SATA drives:
dmamode= For SATA drive only. Attempt to negotiate at the specified DMA transfer mode. If a DMA transer mode cannot be negotiate, the next slower mode is attempted until a mode can be negotiated (udma5, udma4 udma0, mdma 2 mdma0).
udma0 Ultra DMA Mode 0
udma1 Ultra DMA Mode 1
udma2 Ultra DMA Mode 2
udma3 Ultra DMA Mode 3
udma4 Ultra DMA Mode 4
udma5 Ultra DMA Mode 5
mdma0 Multi DMA Mode 0
mdma1 Multi DMA Mode 1
mdma2 Multi DMA Mode 2
speed= Set the speed of physical drive(s).
1.5gb 1.5 GB/s
The following settings are only for SAS drives:
readcache= Applied to SAS drive only. Enables or disables read cache on the physical drive(s).
-v Verbose mode. Used with -a list.

phydrv -a locate -p 9
phydrv -a mod -s "writecache=enable,rlacache=enable"
phydrv -a offline -p 8
phydrv -a online -p 8
ptiflash [-a ] [-t] [-s ] -f [-p ]
The ptiflash command is a flash update utility that installs flash image files.
Download the flash image file from the Promise website: www.promise.com
-a Specifies the action to perform.
start (Default) Starts the flash process. Note: Run only one flash process at a time.
versioninfo Subsystems only. Displays the version and build information of all the flash images of all controllers or the specified controller.
-t Subsystems only. Specifies a TFTP server. Required for embedded subsystems.
Subsystems only. Specifies the hostname or the IP address of the TFTP server which contains the flash image file.
-f Specifies the filename of the flash image file.
ptiflash -f · -s

-p Subsystems only. Specifies the port number of the TFTP server. If no port number is given, the default value of 69 is used.
ptiflash -f fw_multi_20051022.img[for SuperTrak controllers]
ptiflash -t -s 192.168.1.1 -f fw_multi_20031010.img -p 69[for embedded Subsystems]
ptiflash -f fw_multi_20031010.img[for in-band Subsystems]
rc [-a ] [-l ]
rc -a start -l [-n] [-p]
rc -a stop -l
rc -a pause -l
rc -a resume -l
Th rc command starts, stops, pauses and resumes a Redundancy Check and monitors the progress of a running Redundancy Check.
-a Specifies action to perform.
list (Default) Displays active and paused Redundancy Checks and their status.
start Starts a Redundancy Check.
stop Stops a Redundancy Check.
pause Pauses a Redundancy Check.
resume Resumes a paused Redundancy Check.
-l Specifies the logical drive ID on which to run the Redundancy Check.
-n Do not fix inconsistent data. This option causes Redundancy Check to run without correcting inconsistent data. All inconsistency errors are reported.
-p Pause on error. This option causes Redundancy Check to pause when it encounters inconsistent data. The default is to continue on error.

rc -a start -l3 -n -p
rc -a start -l3
rc -a stop -l2
rb [-a ] [-d ] [-s ]
rb -a start -d -s -p
rb -a stop -d -s
rb -a pause -d -s
rb -a resume -d -s
The rb command starts, stops, pauses, and resumes a Rebuild and monitors the progress of a running Rebuild.
-a Specifies action to perform.
list (Default) Displays the running and paused Rebuilds and their status.
start Starts a manual Rebuild.
stop Stops a Rebuild.
pause Pauses a Rebuild.
resume Resumes a paused Rebuild.
-d Specifies which disk array on which to perform the Rebuild.
-s Specifies the sequence number of the failed physical drive. The source drive of the Rebuild.
-p Specifies the ID of the replacement physical drive. The target drive of the Rebuild.
rb -a start -d0 -s2 -p10
rb -a stop -d0 -s2
rc · rb

sc [-a ] [-i ]
sc -a start [-i ]
The sc command starts a Spare Check and monitors the status of a running Spare Check.
-a Specifies the action to perform.
list (Default) Displays Spare Check status.
start Starts the Spare Check.
-i Specifies the spare ID on which to run Spare Check. Valid value range is 0~255.
sc -a start -i 3
spare -a list [-i ] [-d ] [-v]
spare -a add [-i ] -p [-t g|d] [-r y|n] [-d ] [-s ""]
spare -a mod -i [-t g|d] [-r y|n] [-d ] [-s ""]
spare -a del -i
The spare command displays a list of hot spare drives and creates, modifies, and deletes hot spare drives.
A global hot spare can replace a failed drive from any redundant disk array.
A dedicated hot spare is assigned to one or more redundant disk arrays, and can only replace a drive that belongs to one of the assigned arrays.
A revertible hot spare can be transitioned back to spare status after it replaces a failed drive in a disk array. See transit on page 217.
The hot spare drive must be of equal or greater size than the drive it replaces.
sc · spare [-a ]

-a Specifies the action to perform.
list (Default) Displays a list of hot spare drives.
add Adds new hot spare drives.
mod Changes hot spare drive settings.
del Deletes a hot spare drive.
-i Specifies the ID of the spare drive.
-p Specifies the ID of the physical drive. Requires the -a add option to configure a drive as a spare.
-d
Specifies the disk array ID. Requires the -a list option. Displays a list of global spares and spares dedicated to this disk array. When used with other actions, it specifies the disk array IDs to which this spare is dedicated.
-t Specifies the type of hot spare drive.
g A global hot spare drive.
d A dedicated hot spare drive.
-r Specifies whether the spare drive is revertible.
y Yes.
n No.
-s "=" Specifies options for the spare drive.
mediapatrol= Enables or disables Media Patrol.
spare -a add -p 14 -t g -r y
spare -a mod -i 1 -t d -d 0,1 -s "mediapatrol=disable"
spare -a del -i 0
spath [-a list] [-t -p ] [-c ]
spath -a chgpath [-t -p ]

The spath command discovers and changes subsystem paths.
-a Which action to perform.
list (Default) Lists the subsystem paths that have been discovered.
discover Discovers subsystem paths.
chgpath Changes the current subsystem path to the new specified path. If -t -p is not specified, it will list the current subsystem path.
-t Specifies the type of path.
hba HBA.
subsys Subsystem. With the -a list option, the default is both HBA and Subsystem. With the -a chgpath options, you must specify -t and -p to change the path. You cannot use the -t option with the -a discover option.
-p Specifies the path number of the HBA and subsystem. The path number starts from 1.
-c Specifies the number of paths to be displayed. Not currently supported.
spath -a chgpath -t subsys -p 1
stats [-t ] [-i ] [-c ]
The stats command displays statistics of subsytem, controller, enclosure, physical drives, and logical drives; and resets the statistics count to zero.
spath · spath -a discover · stats -a clear

-a Specifies the action to perform.
list (Default) Displays the statistics.
clear Resets the statistics count to zero.
-t Specifies the device type.
ctrl Controller.
logdrv Logical drive.
phydrv Physical drive.
all All the above options.
-i Specifies the device ID. Default is the first available device ID.
-c Specifies the device count. Default is all devices.
stats -t logdrv -i 0 -c 5
stats -a list -t all
subsys [-a ] [-v]
subsys -a mod -s ""
subsys -a lock [-r] [-t ]
subsys -a unlock [-f]
The subsys command displays and changes subsystem settings and locks the subsystem so that only you can make modifications.
-a Specifies the action to perform.
list (Default) Displays information for the specified subsystem.
mod Modifies subsystem settings.
lock Locks the subsystem so other users cannot apply changes.
stats -a clear · subsys -a chklock

Other users must wait for you to unlock the system or for your lock to expire.
unlock Clears a subsystem lock.
chklock Checks the status of the lock.
-s "=" Specifies which subsystem settings to change.
alias= User-specified name for the subsystem. Up to 48 characters, alpha-numeric characters, blank spaces and underscores. Beginning and ending blank spaces are discarded.
-t Specifies the number minutes to lock the subsystem. Requires the -a lock option. Default is 30 minutes.
-r Renews the lock timer. Requires the -a lock and -t options.
-f Specifies a forced unlock. Requires super user privilege.
-v Specifies verbose mode.
subsys -a mod -s "alias=MySubsystem"
subsys -a lock -t 60
subsys -a lock -r -t 35
sync [-a ] [-l ]
The sync command monitors the progress of background synchronization.
Background synchronization makes logical drive consistent. It starts automatically when a redundant logical drive is created. But unlike initialization, background synchronization allows read and write operations on the logical drive. If an initialization starts, the background synchronization pauses until the initialization has finished.
Since background synchronization is starts, pauses, and resumes automatically, there is no need for start, stop, pause, or resume functions.

-a Specifies the action to perform.
list (Default) Displays the current background synchronization activities and their status.
-l Specifies the logical drive ID on which background synchronization is running.
sync -a list -l3
topology [-a ] [-v]
The topology command displays enclosure topology, physical connections, and devices. For products that support multiple enclosures only.
-a Specifies the action to perform.
list (Default) Displays topology information.
-v Displays complete information about topology.
transit
Usage
transit [-a ] [-d ] [-s ]
transit -a start -d -s -p
transit -a stop -d -s
transit -a pause -d -s
transit -a resume -d -s
The transit command starts, stops, pauses, and resumes a transition and monitors the progress of a running transition.
sync · sync -l3 · topology

Transition is an operation to replace a revertible spare drive currently used in a disk array with an new physical drive, so the reveritible spare can be restored to spare drive status. The destination drive can be an unconfigured drive, a non- revertible global spare, or a non-revertible spare dedicated to the array.
During transition, the data on the revertible spare is transferred to the destination drive while the disk array remains online. After transition, the destination drive becomes the part of the array and the revertible spare is a spared drive once again.
-a Specifies the action to perform.
list (Default) Displays the running and paused transitions and their status.
start Starts a manual transition.
stop Stops a transition.
pause Pauses a transition.
resume Resumes a paused transition.
-d Specifies the id of disk array which contains the revertible spare drive.
-s Specifies the sequence number of the revertible spare drive in the array.
-p Specifies the physical drive ID of the destination drive.
transit -a start -d 0 -s 2 -p 10
transit -a stop -d 0 -s 2
transit

RAID (Redundant Array of Independent Disks) allows multiple physical drives to be combined together in a disk array. Then all or a portion of the disk array is formed into a logical drive. The operating system sees the logical drive as a single storage device, and treats it as such.
The RAID software and controller manage all of the individual drives. The benefits of a RAID can include:
Different types of logical drives use different organizational models and have varying benefits. Also see “Choosing a RAID Level” on page 232. The following outline breaks down the properties for each type of RAID logical drive:

When a logical drive is striped, the read and write blocks of data are interleaved between the sectors of multiple physical drives. Performance is increased, since the workload is balanced between drives or “members” that form the logical drive. Identical drives are recommended for performance as well as data storage efficiency.
Figure 1. RAID 0 Striping interleaves data across multiple drives

The logical drive's data capacity equals the capacity of the smallest physical drive times the number of physical drives. For example, one 100 GB and three 120 GB drives will form a 400 GB (4 x 100 GB) logical drive instead of 460 GB.
If physical drives of different capacities are used, there will also be unused capacity on the larger drives.
RAID 0 logical drives on SuperTrak consist of one or more physical drives.
Data Stripe · Physical Drives

When a logical drive is mirrored, identical data is written to a pair of physical drives, while reads are performed in parallel. The reads are performed using elevator seek and load balancing techniques where the workload is distributed in the most efficient manner. Whichever drive is not busy and is positioned closer to the data will be accessed first.
With RAID 1, if one physical drive fails or has errors, the other mirrored physical drive continues to function. Moreover, if a spare physical drive is present, the spare drive will be used as the replacement drive and data will begin to be mirrored to it from the remaining good drive.
Figure 2. RAID 1 Mirrors identical data to two drives

The logical drive’s data capacity equals the smaller physical drive. For example, a 100 GB physical drive and a 120 GB physical drive have a combined capacity of 100 GB in a mirrored logical drive.
If physical drives of different capacities are used, there will be unused capacity on the larger drive.
RAID 1 logical drives on SuperTrak consist of two physical drives.
If you want a mirrored logical drive with more than two physical drives, see “RAID 1E – Enhanced Mirror” on page 222 and “RAID 10 – Mirror / Stripe” on page 225.
Data Mirror · Physical Drives

RAID 1E offers the security of mirrored data provided by RAID 1 plus the added capacity of more than two physical drives. It also offers overall increased read/ write performance plus the flexibility of using an odd number of physical drives. With RAID 1E, each data stripe is mirrored onto two physical drives. If one drive fails or has errors, the other drives continue to function, providing fault tolerance.
Figure 3. RAID 1E can mirror data over an odd number of drives

The advantage of RAID 1E is the ability to use an odd number of physical drives, unlike RAID 1 and RAID 10. You can also create a RAID 1E Logical Drive with an even number of physical drives. However, with an even number of drives, you will obtain somewhat greater security with comparable performance using RAID 10.
RAID 1E logical drives consist of three or more physical drives. You can create an array with just two physical drives and specify RAID 1E. But the resulting array will actually be a RAID 1.
Enhanced Data Mirrors · Physical Drives

RAID 5 organizes block data and parity data across the physical drives. Generally, RAID Level 5 tends to exhibit lower random write performance due to the heavy workload of parity recalculation for each I/O. RAID 5 is generally considered to be the most versatile RAID level. It works well for file, database, application and web servers.
Figure 4. RAID 5 stripes all drives with data and parity information

The capacity of a RAID 5 logical drive equals the smallest physical drive times the number of physical drives, minus one. Hence, a RAID 5 logical drive with four 100 GB physical drives will have a capacity of 300 GB. A RAID 5 logical drive with two 120 GB physical drives and one 100 GB physical drive will have a capacity of 200 GB.
RAID 5 is generally considered to be the most versatile RAID level.
A RAID 5 on SuperTrak consists of 3 to 16 physical drives.
Distributed Parity · Data Blocks · Physical Drives

RAID level 6 stores dual parity data is rotated across the physical drives along with the block data. A RAID 6 logical drive can continue to accept I/O requests when any two physical drives fail.
Figure 5. RAID 6 stripes all drives with data and dual parity
Double Distributed (P and Q) Parity

The total capacity of a RAID 6 logical drive is the smallest physical drive times the number of physical drives, minus two.
Hence, a RAID 6 logical drive with (7) 100 GB physical drives will have a capacity of 500 GB. A RAID 6 logical drive with (4) 100 GB physical drives will have a capacity of 200 GB.
RAID 6 becomes more capacity efficient in terms of physical drives as the number of physical drives increases.
RAID 6 provides double fault tolerance. Your logical drive remains available when up to two physical drives fail.
RAID 6 is generally considered to be the safest RAID level.
A RAID 6 on SuperTrak consists of 4 to 16 physical drives.
Data Blocks · physical drives

Mirror/Stripe combines both of the RAID 0 and RAID 1 logical drive types. RAID 10 is similar though not identical to RAID 0+1. It can increase performance by reading and writing data in parallel while protecting data with duplication. The data on one drive pair is mirrored together, then striped over a second drive pair.
Figure 6. RAID 10 takes a data mirror on one drive pair and stripes it over a second drive pair

The data capacity RAID 10 logical drive equals the capacity of the smallest physical drive times the number of physical drives, divided by two.
In some cases, RAID 10 offers double fault tolerance, depending on which physical drives fail.
RAID 10 arrays require an even number of physical drives and a minimum of four.
For RAID 10 characteristics with an odd number of physical drives, use RAID 1E.
Data Stripe · Data Mirror · Physical Drives

RAID 50 combines both RAID 5 and RAID 0 features. Data is striped across physical drives as in RAID 0, and it uses distributed parity as in RAID 5. RAID 50 provides data reliability, good overall performance, and supports larger volume sizes.
Figure 7. RAID 50 is a combination of RAID 5 and RAID 0

The data capacity RAID 50 logical drive equals the capacity of the smallest physical drive times the number of physical drives, minus two.
RAID 50 also provides very high reliability because data is still available even if multiple physical drives fail (one in each axle). The greater the number of axles, the greater the number of physical drives that can fail without the RAID 50 logical drive going offline.
Number of Axles 2 16
Physical Drives per Axle 3 16
Physical Drives per Logical Drive 6 256

When you create a RAID 50, you must specify the number of axles. An axle refers to a single RAID 5 logical drive that is striped with other RAID 5 logical drives to make RAID 50. An axle can have from 3 to 16 physical drives, depending on the number of physical drives in the logical drive.
The chart below shows RAID 50 logical drives with 6 to 16 physical drives, the available number of axles, and the resulting distribution of physical drives on each axle.
RAID 50 Logical Drive
No. of Drives No. of Axles Drives per Axle

RAID 50 Logical Drive
No. of Drives No. of Axles Drives per Axle

RAID 60 combines both RAID 6 and RAID 0 features. Data is striped across disks as in RAID 0, and it uses double distributed parity as in RAID 6. RAID 60 provides data reliability, good overall performance and supports larger volume sizes.
Figure 8. RAID 60 is a combination of RAID 6 and RAID 0

The total capacity of a RAID 60 logical drive is the smallest physical drive times the number of physical drives, minus four.
RAID 60 also provides very high reliability because data is still available even if multiple physical drives fail (two in each axle). The greater the number of axles, the greater the number of physical drives that can fail without the RAID 60 logical drive going offline.
Number of Axles 2 16
Physical Drives per Axle 4 16
Physical Drives per Logical Drive 8 256

When you create a RAID 60, you must specify the number of axles. An axle refers to a single RAID 6 logical drive that is striped with other RAID 6 logical drives to make RAID 60. An axle can have from 4 to 16 physical drives, depending on the number of physical drives in the logical drive.
The chart below shows RAID 60 logical drives with 8 to 20 physical drives, the available number of axles, and the resulting distribution of physical drives on each axle.
RAID 60 Logical Drive
No. of Drives No. of Axles Drives per Axle

RAID 60 Logical Drive
No. of Drives No. of Axles Drives per Axle

There are several issues to consider when choosing the RAID Level for your logical drive. The following discussion summarizes some advantages, disadvantages and applications for each choice.
Implements a striped logical drive, the data is broken down into blocks and each block is written to a separate physical drive
Not a true RAID because it is not fault- tolerant
The failure of just one drive will result in all data in an logical drive being lost
I/O performance is greatly improved by spreading the I/O load across many channels and drives
Should not be used in mission critical environments
No parity calculation overhead is involved
Recommended applications for RAID 0:
Simplest RAID storage subsystem design
Very high physical drive overhead – uses only 50% of total capacity
Can increase read performance by processing data requests in parallel since the same data resides on two different drives
Recommended applications for RAID 1:
Advantages Disadvantages · Advantages Disadvantages

Implemented as a mirrored logical drive whose segments are RAID 0 logical drives High I/O rates are achieved thanks to multiple stripe segments Can use an odd number of physical drives
Very high physical drive overhead – uses only 50% of total capacity
Recommended Applications for RAID 1E
High Read data transaction rate
Physical drive failure has a medium impact on throughput
Medium Write data transaction rate
Good aggregate transfer rate
Most versatile RAID level
Recommended applications for RAID 5:
Advantages Disadvantages · Advantages Disadvantages

High Read data transaction rate
High physical drive overhead – equivalent of two drives used for parity
Medium Write data transaction rate
Good aggregate transfer rate
Slightly lower performance than RAID 5
Recommended applications for RAID 6:
Implemented as a mirrored logical drive whose segments are RAID 0 logical drives
Very high physical drive overhead – uses only 50% of total capacity
High I/O rates are achieved thanks to multiple stripe segments
Recommended applications for RAID 10:
Advantages Disadvantages · Safest RAID level · Advantages Disadvantages

High Read data transaction rate
Physical drive failure has a moderate impact on throughput
Good write data transaction rate
Very good aggregate transfer rate
Most versatile RAID level
Recommended applications for RAID 50:
High Read data transaction rate
High disk overhead – equivalent of two drives used for parity
Medium Write data transaction rate
Good aggregate transfer rate
Slightly lower performance than RAID 50
Recommended Applications for RAID 60:
Advantages Disadvantages · Advantages Disadvantages · Safest RAID level

You set the stripe block size, also called block size, when you create a logical drive. With SuperTrak, the choices are 64 KB, 128 KB, 256 KB, 512 KB, and 1024 KB. 64 KB is the default.
Your choice will directly affect performance. There are two issues to consider when choosing the stripe block size.
A larger value slows the logical drive down because physical drives with smaller cache buffers need more time for multiple accesses to fill their buffers.
Generally speaking, email, POS, and webservers prefer smaller stripe block sizes. Video and database applications prefer larger stripe block sizes.
See “Creating a Logical Drive” on page 93 and “Creating a Logical Drive” on page 159, and “Creating a Disk Array – Advanced Configuration” on page 155.
You set the sector size when you create a logical drive. With SuperTrak, the choices are 512 B, 1 KB, 2 KB, and 4 KB. 512 B is the default.
A sector is the smallest addressable area on a physical drive. Sector Size refers to the size of sector measured by the number of bytes of data it can hold. The most common sector size is 512 bytes (512 B). A smaller sector size results in a more efficient use of a physical drive’s capacity. 512 B is the default sector size for logical drives on SuperTrak.
The number of usable sectors is limited by the addressing method of the computer's operating system:

See “Creating a Logical Drive” on page 93 and “Creating a Logical Drive” on page 159, and “Creating a Disk Array – Advanced Configuration” on page 155.
If your Host PC runs Windows XP (32-bit), and you want to create logical drives larger than 2 TB, you must choose a sector size larger than 512 B when you create the logical drive. The table on the next page correlates sector size with logical drive capacity.
Logical Drive Size Sector Size
8 to 16 TB 4096 bytes (4 KB)
4 to 8 TB 2048 bytes (2 KB)
2 to 4 TB 1024 bytes (1 KB)
0 to 2 TB 512 bytes (512 B)
Also see “Ranges of Disk Array Expansion” on page 246.
As it is used with SuperTrak, the term cache refers to any of several kinds of high-speed, volatile memory that hold data moving from your computer to the physical drives or vice-versa. Cache is important because it can read and write data much faster than a physical drive. There are read caches, which hold data as it is read from a physical drive; and write caches, which hold data as it is written to a physical drive.
In order to tune the cache for best performance in different applications, user- adjustable settings are provided. Cache settings are made in conjunction with logical drives:

This feature is designed for fault-tolerant logical drives (RAID 1, 1E, 5, 6, 10, and 50). It is generally recommended to use physical drives of the same size in your disk arrays. When this is not possible, physical drives of different sizes will work but the system must adjust for the size differences by reducing or coercing the capacity of the larger drives to match the smaller ones. With SuperTrak, you can choose to enable Capacity Coercion and any one of four methods.
Enable Capacity Coercion and choose the Method in the Controller Settings menu. See “Making Controller Settings” on page 141. The choices are:
Capacity Coercion also affects a replacement drive used in a disk array. Normally, when an physical drive fails, the replacement drive must be the same capacity or larger. However, the Capacity Coercion feature permits the installation of a replacement drive that is slightly smaller (within 1 gigabyte) than the remaining working drive. For example, the remaining working drives can be

80.5 GB and the replacement drive can be 80.3, since all are rounded down to 80 GB. This permits the smaller drive to be used.
Without Capacity Coercion, the controller will not permit the use of a replacement physical drive that is slightly smaller than the remaining working drive(s).
Initialization is highly recommended for logical drives when they are created from a disk array. Initialization sets all data bits in the logical drive to zero. The action is useful because there may be residual data on the logical drives left behind from earlier configurations. You can also perform an Initialization on an existing logical drive.
When you initialize a logical drive, all the data the logical drive will be lost. Backup any important data before you initialize a logical drive.
There are three options for logical drive initialization:
See “Creating a Logical Drive” on page 93 and “Creating a Logical Drive” on page 159, and “Creating a Disk Array – Advanced Configuration” on page 155, and “Initializing a Logical Drive” on page 169.
A hot spare is a physical drive that is connected to the logical drive system but is not assigned as a member of the logical drive. In the event of the failure of a drive within a functioning fault tolerant logical drive, the hot spare is activated as a member of the logical drive to replace the failed drive.
SuperTrak will replace a failed physical drive in a logical drive with a hot spare drive, if one is available. There are two types of hot spare drive:
There is another property you can assign to a hot spare drive:

Whenever possible, having a hot spare drive in your RAID system is good protection against physical drive failure.
Like any other type of fixed disk media in your system, a RAID logical drive must also be partitioned and formatted before use. Use the same method of partitioning and formatting on an logical drive as you would any other fixed disk.
See “Appendix A: Partition and Format” on page 281.
To migrate a disk array is to do one or both:
On SuperTrak, RAID level migration is performed on the disk array but it applies to the logical drives. Migration takes place on an existing Functional disk array without disturbing the existing data. While the disk array is migrating, you can access the data as before. When migration is complete, your disk array will have a different RAID level and/or a larger capacity.
In most cases, you must add one or more physical drives during the migration process. You can never reduce the number of physical drives.
The tables below shows the migration options for a source logical drive according to its RAID level. The available target RAID levels are shown with their requirements.
You must use WebPAM PRO to migrate a disk array. See “Migrating a Disk Array” on page 161.

A RAID 0 source logical drive can migrate to the following target logical drives:
RAID 0 Add physical drives.
RAID 1 2 physical drives only. Only a single-drive RAID 0 can migrate to RAID 1 by adding 1 physical drive.
RAID 1E 3 or more physical drives.
RAID 5 3 physical drives minimum, 16 maximum. RAID 0 must have less than 16 physical drives.
RAID 6 4 physical drives minimum, 16 maximum.
RAID 10 4 physical drives minimum. Even number of physical drives.
RAID 50 6 physical drives minimum, 16 per axle maximum.
RAID 60 8 physical drives minimum, 16 per axle maximum.
Target Requirements

A RAID 1 Source logical drive can migrate to the following Target logical drives:
RAID 0 None.
RAID 1E 3 or more physical drives.
RAID 5 3 physical drives minimum, 16 maximum. RAID 1 must have less than 16 physical drives.
RAID 10 4 physical drives minimum. Even number of physical drives.
RAID 50 6 physical drives minimum, 16 per axle maximum.
A RAID 1E Source logical drive can migrate to the following Target logical drives:
RAID 0 None.
RAID 1E Add physical drives.
RAID 5 3 physical drives minimum, 16 maximum. RAID 1E must have less than 16 physical drives.
RAID 10 4 physical drives minimum. Even number of physical drives.
RAID 50 6 physical drives minimum, 16 per axle maximum.
Target Requirements · Target Requirements

A RAID 5 Source logical drive can migrate to the following Target logical drives:
RAID 0 None.
RAID 1E None.
RAID 5 Add physical drives. 16 maximum.
RAID 6 4 physical drives minimum, 16 maximum.
RAID 10 4 physical drives minimum. Even number of physical drives.
RAID 50 6 physical drives minimum, 16 per axle maximum.
RAID 60 8 physical drives minimum, 16 per axle maximum.
A RAID 6 Source logical drive can migrate to the following Target logical drives:
RAID 6 Add physical drives. 16 maximum.
RAID 60 8 physical drives minimum, 16 per axle maximum.
Target Requirements · Target Requirements

A RAID 10 Source logical drive can migrate to the following Target logical drives:
RAID 0 None.
RAID 1E None.
RAID 5 3 physical drives minimum, 16 maximum. RAID 10 must have less than 16 physical drives.
RAID 6 4 physical drives minimum, 16 maximum. RAID 10 must have less than 16 physical drives.
RAID 10 Add physical drives. Even number of physical drives.
RAID 50 6 physical drives minimum, 16 per axle maximum.
RAID 60 8 physical drives minimum, 16 per axle maximum.
Target Requirements

A RAID 50 Source logical drive can migrate to the following Target logical drives:
RAID 0 None.
RAID 1E None.
RAID 5 16 physical drives maximum. RAID 50 must have less than 16 physical drives.
RAID 6 16 physical drives maximum. RAID 50 must have less than 16 physical drives.
RAID 10 Even number of physical drives.
RAID 50 Add physical drives. 16 per axle maximum.
RAID 60 8 physical drives minimum, 16 per axle maximum.
A RAID 60 Source logical drive can migrate to the following Target logical drives:
RAID 6 16 physical drives maximum. RAID 60 must have less than 16 physical drives.
RAID 60 Add physical drives. 16 per axle maximum.
Target Requirements · Target Requirements

The Windows XP (32-bit) operating systems support a 10-byte LBA format. As a result, these OSes can only recognize 4 billion addresses. If you create a logical drive using the default 512 B sector size, the logical drive will be limited to 2 TB of data, even if there is more space available on your physical drives.
This limitation does not apply to Windows XP (64-bit), 2003 Server, Vista, and Linux OSes with the 2.6 kernel. Linux OSes with the 2.4 kernel do not support variable sector sizes, therefore you cannot apply the solution described here to those OSes.
You can direct WebPAM PRO to expand a logical drive beyond the maximum expansion size. When the expansion is finished:

Current LD Size Maximum LD Expansion Size Sector Size
8 to 16 TB 16 TB 4096 bytes
4 to 8 TB 8 TB 2048 bytes
2 to 4 TB 4 TB 1024 bytes
up to 2 TB 2 TB 512 bytes
At this point, you have the choice of:
If you require a logical drive larger than the maximum expansion size:
See “Deleting a Logical Drive” on page 95 or page 160.
See “Creating a Logical Drive” on page 93 or page 159.

Media Patrol is a routine maintenance procedure that checks the magnetic media on each physical drive. Media Patrol checks all physical drives assigned to disk arrays and on spare drives. Media Patrol does not check unconfigured drives.
Unlike Synchronization and Redundancy Check, Media Patrol is concerned with the condition of the media itself, not the data recorded on the media. If Media Patrol encounters a critical error, it triggers PDM if PDM is enabled.
You can run Media Patrol from the subsystem. See “Running Media Patrol” on page 134.
You can also run Media Patrol on a disk array. See “Running Media Patrol on a Disk Array” on page 163.
Predictive Data Migration (PDM) is the migration of data from the suspect physical drive to a spare drive, similar to Rebuilding a Logical Drive. But unlike Rebuilding, PDM constantly monitors your physical drives and automatically copies your data to the spare drive before the suspect drive fails and your Logical Drive goes Critical. See “Running PDM” on page 135 and “Running PDM on a Disk Array” on page 163.
After the data is copied from the suspect drive, the controller marks the suspect drive with a Stale configuration and a PFA error.
You can clear the Stale configuration and PFA error and put the physical drive back into service. See “Clearing Stale and PFA Conditions” on page 149 or page 265. In some cases, however, you might remove the physical drive for repair or replacement.
The following actions trigger PDM:
*PDM also counts the number of media errors reported by Media Patrol.
A physical drive becomes unhealthy when:

Because data would be lost if written to a bad sector, when a bad sector is detected, the physical drive creates a map around it. These maps are saved in the bad sector remapping table, which has a capacity of 512 reassigned blocks and 1024 error blocks.
When the table fills to a specified percentage of its capacity, PDM triggers a migration of data from the suspect drive (the physical drive with the bad sectors) to a spare drive.
During data migration, you will have access to the logical drive but it will respond more slowly to read/write tasks because of the additional operation. The time required for data migration depends on the size of the physical drive.
See “Making Background Activity Settings” on page 133.
The Transition feature enables you to specify “permanent” spare drives for your SuperTrak controller. Transition is the process of replacing a revertible spare drive that is currently part of a disk array with an unconfigured physical drive or a non-revertible spare. The revertible spare drive returns to its original status.
Transition happens automatically when the following sequence of events takes place:
Transition happens manually when you specify a different unconfigured physical drive to transition (move) the data from the revertible spare drive.
In the example below, there is a two-drive RAID 1 disk array.


The physical drive in channel 2 fails. The disk array becomes degraded and its logical drives go critical. The SuperTrak controller automatically rebuilds the disk array using the revertible spare drive, the physical drive in channel 4.

When the rebuild is finished, the disk array and logical drives are OK again.


At this juncture, you would replace the failed drive in channel 2 with a new drive of the same or greater capacity.
When the SuperTrak controller detects the new drive in channel 2, it will:
When the Transition is finished:
The original configuration is restored.
Manual transition requires an unassigned physical drive.
The example below is the same two-drive RAID 1 disk array as before.

The physical drive in channel 2 fails. The disk array becomes degraded and its logical drives go critical. The SuperTrak controller automatically rebuilds the disk array using the spare drive, the physical drive in channel 4.
As we saw in the example of Automatic Transition, if you replace the failed physical drive in channel 2, the SuperTrak controller would transition the data from the physical drive in channel 4 to the new drive in channel 2.
But if you wanted to use a different physical drive in your array, such as the unassigned drive in channel 3, you would run the Transition function manually.
When the Manual Transition is finished:
At this point, after running the Manual Transition, you would replace the failed drive in channel 2. The replacement drive in channel 2 will remain unconfigured until you assign it to a disk array or as a spare.

A fault-tolerant logical drive—RAID 1, 1E, 5, 6, 10, 50, or 60—goes critical when a physical drive is removed or fails. Due to the fault tolerance of the logical drive, the data is still available and online. However, once the logical drive goes critical, the logical drive has lost its fault tolerance, and performance may be adversely affected.
If the fault was caused by a failed drive that was removed, the drive must be replaced by another drive, either identical or larger, in order for the RAID system to rebuild and restore optimal configuration.
If your fault-tolerant logical drive—RAID 1, 1E, 5, 6, 10, 50, or 60—goes offline, contact Technical Support. See page 273.
Take no further corrective action until you have consulted with Technical Support. See page 273.
A non-fault tolerant logical drive—RAID 0—goes offline when a physical drive is removed or fails. Since the logical drive is not fault tolerant, the data stored in the logical drive is no longer accessible.
If one physical drive fails, all of the data on the logical drive is lost. You must replace the failed drive. Then, if the logical drive had more than one physical drive, delete the logical drive and re-create it. Restore the data from a backup source.
The SuperTrak EX Controller provides both audible and visual indicators to alert you of a physical drive failure. The following will occur when a physical drive fails or goes offline, WebPAM PRO reports the condition.
WebPAM PRO aids in troubleshooting your logical drives and enclosure by continuous monitoring and reporting to the User in the following ways:




When a physical drive in a disk array fails and a spare drive of adequate capacity is available, the disk array will begin to rebuild automatically using the spare drive.
After the disk array rebuilds itself using the spare drive, you must replace the failed drive.
To set up a spare drive, see “Creating a Spare Drive” on page 173.
If there is no hot spare drive of adequate capacity, you must remove the failed drive and install an unconfigured replacement drive of the same or greater capacity in the same slot as the failed drive. Until you install the replacement drive, the logical drive will remain Degraded.
To enable Automatic Rebuild, see “Making Background Activity Settings” on page 133.
To set Hot Spare Policy, see “Making Spare Drive Settings” on page 174.
If your replacement physical drive was formerly part of a different disk array or logical drive, you must clear the configuration data on the replacement drive before you use it.
See “Clearing Stale and PFA Conditions” on page 149 or page 265.
During rebuild:
Management View reports the disk array’s Operational Status as OK, Rebuilding.
During rebuilding, you can still read and write data to the logical drive. However, fault tolerance is lost until the disk array returns to OK (not-rebuilding) status.

After a successful rebuild:

The SuperTrak EX Controller provides both audible and visual indicators to alert you to a problem.
The buzzer sounds to inform you that your RAID system needs attention. But the buzzer does not specify the condition. When a continuous tone sounds, there are multiple alarm patterns sounding at the same time.
When the buzzer sounds, take the following actions:
If your system is configured with Global LEDs or Direct LEDs, they will indicate when a problem is present. Use the SuperBuild utility or WebPAM PRO to further diagnose and correct the problem.

Global LEDs glow in response to Logical Drive status.
LED Logical Drive Status
Amber Logical Drive Critical
Red Logical Drive Offline
Direct LEDs, glow and blink in response to the SuperTrak’s firmware status.
OFF OFF No physical drive
ON ON Unconfigured physical drive
OFF ON Configured physical drive – Status OK
ON ON Configured physical drive – Status Not OK
OFF ON Global spare drive – Status OK
ON ON Physical drive – Status Dead
ON ON Stale condition
Blink ON Locate physical drive
Blink ON Locate logical drive
Blink ON Locate disk array

The problem is first reported in the SuperTrak BIOS screen when you boot your PC or server, as shown below.
Figure 1. SuperTrak BIOS screen, logical drive critical
If the SuperTrak BIOS detects an Critical logical drive, the BIOS reports the condition but allows the booting process of the Host PC to continue.
Choose a Management application:

Figure 2. SuperTrak BIOS screen, logical drive offline
If the SuperTrak BIOS detects an Offline logical drive, the BIOS reports the condition and temporarily halts the booting process of the Host PC.
Choose a Management application:

Open WebPAM PRO
If WebPAM PRO is not running, do the following actions:
See “Logging into WebPAM PRO” on page 107 for more information.
When a logical drive goes critical or offline, WebPAM PRO reports the condition in the following ways:


A fault-tolerant logical drive—RAID 1, 1E, 5, 6, 10, 50, or 60—goes critical when a physical drive is removed or fails. Due to the fault tolerance of the logical drive, the data is still available and online. However, once the logical drive goes critical, the logical drive has lost its fault tolerance, and performance may be adversely affected.
If the fault was caused by a failed drive that was removed, the drive must be replaced by another drive, either identical or larger, in order for the RAID system to rebuild and restore optimal configuration.
If your fault-tolerant logical drive—RAID 1, 1E, 5, 6, 10, 50, or 60—goes offline, contact Technical Support. See page 273.
Take no further corrective action until you have consulted with Technical Support. See page 273.
A non-fault tolerant logical drive—RAID 0—goes offline when a physical drive is removed or fails. Since the logical drive is not fault tolerant, the data stored in the logical drive is no longer accessible.
If one physical drive fails, all of the data on the logical drive is lost. You must replace the failed drive. Then, if the logical drive had more than one physical drive, delete the logical drive and re-create it. Restore the data from a backup source.
To identify a failed physical drive:
The Physical Drive Management screen displays.

Figure 3. Physical Drive Management screen

ID 3 is missing
In the example above, there is no physical drive for ID 3. Assuming you installed a physical drive onto Channel 3 of the SuperTrak controller, this is the failed physical drive.
To locate a failed or missing physical drive:
See “Logging into WebPAM PRO” on page 107 for more information.

Physical drives can develop problems that make them unsuitable for service in a logical drive. These problems are reflected in the physical drive status:
WebPAM PRO has features to deal with PFA or Stale physical drives. An Offline or Dead physical drive cannot be salvaged and must be replaced.
To clear a Stale or PFA status from a physical drive:
See “Logging into WebPAM PRO” on page 107 for more information.
If a physical drive has both a Stale and a PFA condition, click the Submit button once to clear the Stale condition, then click again to clear the PFA condition.

The remedial action for a critical logical drive is to rebuild it, meaning the data from the failed physical drive is rebuilt onto a spare or replacement physical drive.
The SuperTrak Controller will rebuilt a logical drive automatically using a spare drive, providing:
If the above conditions are met, the SuperTrak controller automatically rebuilds the logical drive with the hot spare. After the rebuild is done, you must replace the failed drive with a new physical drive.
Depending on your spare drive settings, you might make the replacement drive the new spare drive, or the original spare will transition back to its original status. See “Creating a Spare Drive” on page 97 or page 173. Also see “Hot Spare Drive(s)” on page 239.
If a spare drive is not available, you must replace the failed drive. Then the SuperTrak controller will automatically rebuild the logical drive using the new physical drive, providing:
In some cases, you must start the Rebuild manually. After replacing the failed drive with a new drive of equal or larger size, take the following actions:
The Disk Array Management screen displays.
The Disk Array Info and Setting screen displays.

The Manual Rebuild screen displays.
The time required for the Rebuild depends on the number and size of your logical drives. You can monitor the progress of the Rebuild under Background Activity.
If a physical drive has failed, identify and replace the drive, then rebuild the disk array as described below:
If there are multiple disk arrays, choose the icon with the yellow !.
This is a remaining functional physical drive in the disk array.
This is the replacement physical drive.
The Disk Array Background Activity tab will show the rebuild the replacement (target) physical drive. Depending the size of the physical disk involved, this process will take some time.
To view more information, click the Rebuild on PDx link.
To set Rebuild priority, see “Making Background Activity Settings” on page 133.

Occasionally, while you are performing a RAID management operation using WebPAM PRO, your browser screen might go blank.
To recover from a blank browser screen, do one of the following actions:
The RAID controller’s cache backup battery protects data in the cache for up to 72 hours in the event of a power failure. If the battery is too warm, it will not accept a charge nor will it discharge to power the cache.
To view battery information:
In normal operation, the operational status of the battery shows Fully Charged with a Reserve Capacity of 100%. If it never reaches this condition or remains discharged, the battery may be too warm.
RAID controllers, like all components inside the Host PC, rely on a flow of air to carry off heat and maintain optimal temperature. If the air flow is inadequate, performance can suffer.
Check and correct the following conditions:
Measuring and adjusting airflow through a PC or server is very difficult for users in the field. Contact the manufacturer’s Technical Support for assistance.
Internet Explorer · Firefox · Netscape Navigator

This section lists frequently asked questions involving pre-installation, drive issues, installation, and post-installation.
What kind of HDDs can I use for a SuperTrak EX Series logical drive?
You can use any Serial Attached SCSI (SAS) or Serial ATA (SATA) hard disk drive from the compatibility list on the Promise Support Website. Use matching drives for multiple-drive arrays to maximize capacity usage as well as performance.
What is the maximum physical drive storage capacity of SuperTrak EX Series?
The SuperTrak EX4650 supports up to 3.0 TB (four 750 GB physical drives).
The SuperTrak EX8650, EX8654, and EX8658 support up to 6.0 TB (eight 750 GB physical drives).
The SuperTrak EX16650 supports up to 16.0 TB (sixteen 1.0 TB physical drives).
The SuperTrak EX Series controllers also support up to 128 SAS physical drives per SAS port using SAS expanders.
Can I use ATAPI devices on the SuperTrak EX Series?
No. The SuperTrak EX Series Controller does not support ATAPI devices.
Will ACPI work with HDDs on the SuperTrak EX Series?
Yes. The SuperTrak EX Series controller supports ACPI S1, S3 and S4 standby modes.
What kind of PCI slots do the SuperTrak EX Series controllers use?
SuperTrak EX Series controllers will work in a PCI-Express x8 slot or x16 slot.

How can I change the resources that the SuperTrak uses?
The SuperTrak EX Series Controllers are fully PnP. This means all the resources that it uses are given to it by the PnP BIOS on the motherboard.
The SuperTrak Series Controller supports IRQ sharing, but this feature only works when ALL the concerned devices support it. If your motherboard allows you to control the assignment of these resources, you may be able to remedy the problem by:
Can I add a drive to a SuperTrak EX Series logical drive via hot-swap and dynamically adjust the array size/configuration?
Yes. The SuperTrak EX Series controller supports online logical drive expansion and migration. You must use the SuperBuild utility or the WebPAM PRO software to expand or migrate an existing logical drive.
Do the HDDs on the SuperTrak EX Series have to be the same size?
The physical drives that you use with the SuperTrak EX Series controller do not have to be the same size. If the sizes differ, the SuperTrak EX Controller will truncate the large drive so the capacities match. The resulting difference in drive space is unusable, so avoid using physical drives of significantly different capacities.
Can I take a drive used in a SuperTrak EX Series logical drive and access it directly with a different controller, such as the one integrated on the motherboard?
Yes, but only under certain configurations. First, the other controller must address the drives as LBA, not CHS.
Second, only the following configurations allow the drive(s) to be accessed individually on another controller:
No other array configurations will work for this purpose.

I already have an array on a Promise FastTrak controller. Can I move that array to my new SuperTrak EX Series controller?
No. The SuperTrak EX Series controller supports SNIA Disk Data Format (DDF), which is not backward compatible with the FastTrak controller.
If I have a problem with one of the drives on the SuperTrak EX Series, how can I low-level format it to correct the problem?
Do NOT do this! Low-level formatting hard physical drives is not only unnecessary but it generally does not correct problems commonly experienced during use.
Errors such as bad sectors or ECC/CRC failure are best remedied by completely replacing the drive. For this reason, do NOT low-level format the drives attached to the SuperTrak EX Series controller.
Do I have to install disk management software on my logical drive in order to access the full storage capacity of drives?
No! Disk management software will only complicate things. The logical drive should be fully addressable by your OS as it is. Some operating systems have limits on the sizes of partitions and logical drives that can be defined. Consult your OS documentation about partitioning larger drives.
What system BIOS setup settings do I use for the drives on the SuperTrak EX Series?
A BIOS setting is required only if you want to boot your system from the logical drive on the SuperTrak EX Series controller. After your logical drive is created, partitioned and formatted, make the change in your BIOS boot order setting.
How do I partition/format my SuperTrak EX Series RAID logical drive?
The SuperTrak EX Series controller represents the logical drive as a single physical drive to your system. Therefore, anything that you can do to a single physical drive you can do to a SuperTrak logical drive.
For example, you should use the FDISK and FORMAT utilities to partition and format the logical drive. You can format the logical drive with any file system you wish.
How can I change the system boot sequence in order to boot from the SuperTrak EX Series logical drive?
The boot sequence is controlled by the system BIOS. As far as the system BIOS is concerned, the SuperTrak EX Controller and defined logical drives

are categorized as a SCSI device. This allows you to set the boot sequence in your BIOS setup utility to boot from SCSI first, rather than IDE.
If there are multiple SCSI add-in controllers in the system, then the boot sequence among them will be determined exclusively by their PCI slot priority. PCI slot #1 will be first, slot #2 second, etc. Put the SuperTrak EX Controller in the PCI-Express slot where it will be accessed ahead of other SCSI controllers if you want to boot from the logical drive.
How can I change the boot sequence between a PCI SCSI card and the SuperTrak EX Series RAID logical drive?
Since all PCI-Express are PnP, it is difficult to determine which device is addressed first. Most motherboard BIOSes have advanced options that identify devices and allow you to choose which device will be assigned resources first. Otherwise you may have to physically switch the device cards on the PCI/PCI-Express/PCI-X slots so that the boot device is in the highest priority slot number (see previous question).
Why can’t I see the drives on the SuperTrak EX Series under FDISK?
You have not created a logical drive yet. Without a logical drive, the system will not recognize the physical drives attached to the SuperTrak EX Controller.
A physical drive is recognized by the SuperTrak controller but not available to use in a disk array. How can I make it available?
The physical drive might contain obsolete disk array information. See “Clearing Stale and PFA Conditions” on page 149 or page 265. This action clears the obsolete information in order to make the drive available.
Why can’t I run WebPAM PRO in Konqueror?
The Konqueror browser (Linux) does not support WebPAM PRO. Install a Netscape Navigator or Firefox browser. With that browser as the default, reinstall WebPAM PRO.
Aren’t the WebPAM PRO icons supposed to be animated?
Yes, they are animated. However, the default setting for Internet Explorer under Windows 2003 Server does not display animation in the browser. Go to Internet Options > Advanced and check Play animations in web pages.

Promise Technical Support provides several support options for Promise users to access information and updates. We encourage you to use one of our electronic services, which provide product information updates for the most efficient service and support.
If you decide to contact us, please have the following information available:
Promise Online™ Web Site http://www.promise.com/support/ support_eng.asp. (technical documents, drivers, utilities, etc.)
E-mail Support e-Support On-Line
Fax Support +1 408 228 1100 Attn: Technical Support
Phone Support +1 408 228 1400 option 4
If you wish to write us for support:
Promise Technology, Inc. 580 Cottonwood Drive Milpitas, CA 95035, USA
E-mail Support e-Support On-Line
Fax Support +31 0 40 256 9463 Attn: Technical Support
Phone Support +31 0 40 235 2600
If you wish to write us for support:
Promise Technology Europe B.V. Science Park Eindhoven 5542 5692 EL Son, The Netherlands

E-mail Support e-Support On-Line
Fax Technical Support +49 0 2 31 56 76 48 29 Attn: Technical Support
Phone Technical Support +49 0 2 31 56 76 48 10
If you wish to write us for support:
Promise Technology Germany Europaplatz 9 44269 Dortmund, Germany
E-mail Support e-Support On-Line
Fax Support +39 0 6 367 124 00 Attn: Technical Support
Phone Support +39 0 6 367 126 26
If you wish to write us for support:
Promise Technology Italy Piazza del Popolo 18 00187 Roma, Italia
E-mail Support e-Support On-Line
Fax Support +886 3 578 2390 Attn: Technical Support
Phone Support +886 3 578 2395 ext. 8822 or 8823
If you wish to write us for support:
Promise Technology, Inc. 2F, No. 30, Industry E. Rd. IX Science-based Industrial Park Hsin-Chu 30075, Taiwan (R.O.C.)

E-mail Support e-Support On-Line
Phone Support +86 10 8857 8085 or 8095
If you wish to write us for support:
Promise Technology China – Beijing Room 1205, Tower C Webok Time Center, No.17 South Zhong Guan Cun Street Hai Dian District, Beijing 100081, China
E-mail Support e-Support On-Line
Fax Support +86 21 6249 4627 Attn: Technical Support
Phone Support +86 21 6249 4192, 4193, or 4199
If you wish to write us for support:
Promise Technology China – Shanghai Room 508, Leader Tower 1189 West Wu Ding Road Jing An District, Shanghai 200042, China

Promise Technology, Inc. (“Promise”) warrants that this product, from the time of the delivery of the product to the original end user:
a) all components, except the cache backup battery, for a period of three (3) years;
b) the cache backup battery, for a period of one (1) year;
c) will conform to Promise’s specifications;
d) will be free from defects in material and workmanship under normal use and service.
This warranty:
a) applies only to products which are new and in cartons on the date of purchase;
b) is not transferable;
c) is valid only when accompanied by a copy of the original purchase invoice.
d) Is not valid on spare parts.
This warranty shall not apply to defects resulting from:
a) improper or inadequate maintenance, or unauthorized modification(s), performed by the end user;
b) operation outside the environmental specifications for the product;
c) accident, misuse, negligence, misapplication, abuse, natural or personal disaster, or maintenance by anyone other than a Promise or a Promise-authorized service center.
This warranty covers only parts and labor, and excludes coverage on software items as expressly set above.
Except as expressly set forth above, Promise DISCLAIMS any warranties, expressed or implied, by statute or otherwise, regarding the product, including, without limitation, any warranties for fitness for any purpose, quality, merchantability, non-infringement, or otherwise. Promise makes no warranty or representation concerning the suitability of any product for use with any other item. You assume full responsibility for selecting products and for ensuring that the products selected are compatible and appropriate for use with other goods with which they will be used.

Promise DOES NOT WARRANT that any product is free from errors or that it will interface without problems with your computer system. It is your responsibility to back up or otherwise save important data before installing any product and continue to back up your important data regularly.
No other document, statement or representation may be relied on to vary the terms of this limited warranty.
Promise’s sole responsibility with respect to any product is to do one of the following:
a) replace the product with a conforming unit of the same or superior product;
b) repair the product.
Promise shall not be liable for the cost of procuring substitute goods, services, lost profits, unrealized savings, equipment damage, costs of recovering, reprogramming, or reproducing of programs or data stored in or used with the products, or for any other general, special, consequential, indirect, incidental, or punitive damages, whether in contract, tort, or otherwise, notwithstanding the failure of the essential purpose of the foregoing remedy and regardless of whether Promise has been advised of the possibility of such damages. Promise is not an insurer. If you desire insurance against such damage, you must obtain insurance from another party.
Some states do not allow the exclusion or limitation of incidental or consequential damages for consumer products, so the above limitation may not apply to you.
This warranty gives specific legal rights, and you may also have other rights that vary from state to state. This limited warranty is governed by the State of California.
You are responsible for determining whether the product is appropriate for your use and will interface with your equipment without malfunction or damage. You are also responsible for backing up your data before installing any product and for regularly backing up your data after installing the product. Promise is not liable for any damage to equipment or data loss resulting from the use of any product.

If you suspect a product is not working properly, or if you have any questions about your product, contact our Technical Support Staff through one of our Technical Services, making sure to provide the following information:
The technician will assist you in determining whether the product requires repair. If the product needs repair, the Technical Support Department will issue an RMA (Return Merchandise Authorization) number.
Obtain an RMA number from Technical Support before you return the product and write the RMA number on the label. The RMA number is essential for tracking your product and providing the proper service.
Return ONLY the specific product covered by the warranty (do not ship cables, manuals, diskettes, etc.), with a copy of your proof of purchase to:
USA and Canada: Promise Technology, Inc. Customer Service Dept. Attn.: RMA # 47654 Kato Road Fremont, CA 94538
Other Countries: Return the product to your dealer or retailer.
Contact them for instructions before shipping the product.
You must follow the packaging guidelines for returning products:

You are responsible for the cost of insurance and shipment of the product to Promise. Note that damage incurred due to improper transport or packaging is not covered under the Limited Warranty.
When repairing returned product(s), Promise may replace defective parts with new or reconditioned parts, or replace the entire unit with a new or reconditioned unit. In the event of a replacement, the replacement unit will be under warranty for the remainder of the original warranty term from purchase date, or 30 days, whichever is longer.
Promise will pay for standard return shipping charges only. You will be required to pay for any additional shipping options (such as express shipping).



In order for your operating system to recognize and work with the physical drives attached to your SuperTrak EX Controller card, the drives must be partitioned and formatted.
The actions of partitioning and formatting create a file structure on the physical drives with which your operating system can work. In the example below, we show how this is done in Windows. A similar procedure is required for Linux PCs. However, partitioning and formatting in Linux is not automated, therefore please refer to your system documentation for the exact procedure.
If you plan to boot your computer from this logical drive, you will perform partitioning and formatting during the OS installation. The instructions here are for data logical drives only.






This process will take some time. The Disk Management window displays the progress.


When formatting is complete, your logical disk will appear as a hard drive in the Disk Management window (above) and the My Computer window (below).


Follow this procedure to upgrade the BIOS and Firmware on your SuperTrak EX4650, EX8650, EX8654, EX8658, or EX16650 Controller card.
The SuperTrak card must be properly installed in your PC or server in order to perform the update. See “Installing the SuperTrak Card” on page 9 for more information.
The list of available downloads displays. The firmware and BIOS come together in a single package.
After you update your BIOS and Firmware, install the latest SuperTrak driver for your OS. See “Chapter 3: Installing Drivers” on page 59.

Follow this procedure to upgrade the WebPAM PRO Software on your PC or server.
The list of the current WebPAM PRO software displays. Promise provides versions of WebPAM PRO software for Windows and Linux. Be sure you choose the latest version.
The result is a single installer file.
You must manually uninstall the existing version of WebPAM PRO before installing the new one.
See “Installing WebPAM PRO onto Windows” on page 39 or “Installing WebPAM PRO onto Linux” on page 47.
The new version of WebPAM PRO has the same login procedure as previous version. See “Logging into WebPAM PRO” on page 55 or page 107.

The Battery Backup Unit (BBU) maintains power to the cache on the SuperTrak EX Controller card, when a power failure occurs to the Host PC. The failure could be due to a problem with the PC’s power supply, a cessation of electrical service, or an accidental disconnection of the power cable.
When power is interrupted, any data in the controller’s cache is lost. The BBU maintains power to the cache so that any data stored there is saved until it can be written to a physical drive.
The BBU is available as a kit, sold separately from the SuperTrak EX Controller card.
Be sure you obtain and install the correct kit for your controller.
The BBU kit includes the following components:
Figure 1. The BBU-Plus III kit


The electronic components on the SuperTrak EX Controller cards are sensitive to damage from Electro-Static Discharge (ESD). Observe appropriate precautions at all times when handling the SuperTrak card or its subassemblies.
Before installing the BBU onto SuperTrak EX Controller card, backup any important or useful data. Failure to follow this accepted PC practice could result in data loss.
To install the BBU onto your SuperTrak EX Controller card in the Host PC:

Figure 2. BBU module connectors on EX4650. Other models are similar
SuperTrak EX Controller Battery Assembly

Figure 3. Three screws secure the Battery Assembly. The EX4650 is shown. Other models are similar
Back of SuperTrak EX Controller

Mounting screw 1 of 3
BBU module connector

See “Logging into WebPAM PRO” on page 107.
After installation and power-up, a new battery takes several hours to charge. From that time, it should show Fully Charged. See “Viewing Battery Information” on page 142.
The BBU module is covered by a one-year warranty. See “Limited Warranty” on page 276.

To set up LED configuration for your enclosure or PC, make your backplane connections as shown below. You can make connections for:
For SuperTrak EX8654 and EX8658, note that only the interior SAS Ports have individual LED pins.
For more information, see “Installing the SuperTrak Card” on page 9 and the user manual for your PC or enclosure.
Figure 1. SuperTrak Aggregate and Global LED backplane connections
Backplane SuperTrak Controller Card
LED activity = Low
pin pitch 2.54 mm
0 Ω
1 2 3 4
0 Ω
LED R+G
pin pitch 2.54 mm
Optional resistors for tuning LED brightness.

Figure 2. SuperTrak fault and activity LED connections

3 4 5 6 7 8 9 10 11 12 13 14 15 16
For LED status and behavior information, see the tables on the following pages.

Direct LEDs, glow and blink in response to the SuperTrak’s firmware status.
OFF OFF No physical drive
ON ON Unconfigured physical drive
OFF ON Configured physical drive – Status OK
ON ON Configured physical drive – Status Not OK
OFF ON Global spare drive – Status OK
ON ON Physical drive – Status Dead
ON ON Stale condition
Blink ON Locate physical drive
Blink ON Locate logical drive
Blink ON Locate disk array
For more information, see:
Aggregate LEDs glow or blink in response to Storage Device (physical drive) activity.
LED Storage Device Status
ON Storage device (physical drive) activity

Global LEDs glow in response to Logical Drive status.
LED Logical Drive Status
Amber Logical Drive Critical
Red Logical Drive Offline
When a Global LED glows amber or red, you must diagnose and resolve the logical drive problem in the SuperBuild BIOS or in WebPAM PRO.
See “Chapter 8: Troubleshooting” on page 257.
Dark System off · Green Normal