EN
Procom logo
Official user manual

Procom PL600HYLB

13 pages·591 KB·Outdoor Fireplace·PDF·ENDEFRITNLJA
Procom PL600HYLB
Table of Contents 63 sections CAMPFIRE · OWNER’S OPERATION AND INSTALLATION MANUAL · PL600HYLA/PL600HYLB · 60,000BTU/Hr PN750HYLA/PN750HYLB · … ShowHide
CAMPFIREp.1OWNER’S OPERATION AND INSTALLATION MANUALp.1PL600HYLA/PL600HYLBp.160,000BTU/Hr PN750HYLA/PN750HYLBp.1WHAT TO DO IF YOU SMELL GAS:p.1WARNING: For Outdoor Use Only. Do not use for cookingp.1GENERAL INFORMATIONp.2TABLE OF CONTENTSp.2GENERAL INFORMATION ……………………………………………………………….........2p.2SAFETY INFORMATION ………………………………………………………………...........3p.2INSTALLATION .……………………………………………………………………..……....... 5p.2OPERATING HEATER ………………………………………………..…………………........7p.2MAINTENANCE AND STORAGE ……………………………………………………..........8p.2PRODUCT FEATURES ……………………………………………………………………......9p.2SPECIFICATION …………………………………………………………….........…………...10p.2TROUBLESHOOTING ……………………………………………………………………... ..10p.2PARTS LIST …………………………………………………………… …………………….....11p.2SAFETY INFORMATIONp.3PROPER CLEARANCES FROM COMBUSTIBLE, CON-p.3THIS APPLIANCE SHOULD NEVER BE PLACEDp.3Locationp.3Location Continuep.4LOCAL CODESp.4Installationp.5LOGS LISTp.5PL600HYLA PN750HYLAp.5PL600HYLB PN750HYLBp.5Installation continuep.6INSTALLATION INSTRUCTIONS:p.6Installation (continue)p.7OPERATING HEATERp.7CONNECTING TO GAS SUPPLYp.7LIGHTING INSTRUCTIONSp.8WARNING:FOR YOUR SAFETY READp.8BEFOR LIGHTINGp.8MAINTENANCE AND STORAGEp.8PRODUCT FEATURESp.9SERVICE INDICATIONS:p.9SAFETY PILOTp.9PIEZO IGNITION SYSTEMp.9REPLACEMENTp.9REPLACEMENT PARTS:p.9*Option Screen*p.9For Your safetyp.9PARTS UNDER WARRANTY :p.9CAUTIONp.9PLEASE DO NOT TOUCH SCREEN OR PLACE ANYp.9OBJECTS ON SCREEN WHILE BURNER IS ONp.9PARTS NOT UNDER WARRANTY:p.9ACCESSORIESp.10TROUBLESHOOTINGp.10POSSIBLE CAUSEp.10REMEDYp.10PARTS LISTp.11PN750HYLA/PN750HYLBp.11ILLUSTRATEDp.12PARTS BREAKDOWNp.12PL600HYLA / PL600HYLBp.12PN750HYLA / PN750HYLBp.12WARRANTY INFOR ATIONp.13KEEP THIS WARRANTYp.13LIMITED WARRANTY PRO-COM OUTDOOR CAMPFIREp.13PRO-COM TOLLFREE NUMBER: 18778865989p.13
Page 1 of the Procom PL600HYLB user manual — WARNING: For Outdoor Use Only. Do not use for cooking
Page 1 · click to enlarge
Page 1
Procom PL600HYLB — CAMPFIRE diagram (page 1)
Fig. 1

CAMPFIRE

OWNER’S OPERATION AND INSTALLATION MANUAL

Procom PL600HYLB — CAMPFIRE diagram (page 1)
Fig. 2

PL600HYLA/PL600HYLB

60,000BTU/Hr PN750HYLA/PN750HYLB

Procom PL600HYLB — PL600HYLA/PL600HYLB diagram (page 1)
Fig. 3

not followed exactly, a fire or explosion may

result causing property damage, personal injury,

or loss of life.

FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

carefully and completely before trying to

assemble, operate, or service this heater.

WHAT TO DO IF YOU SMELL GAS:

-Shut off supply to the appliance.

-Extenguish any open flames.

alteration, service, or maintenance can cause

-Immediately call your gas supplier. Follow

injury or property damage. Read the installation, operating and maintenance instructions

the gas supplier’s instructions. -If you can not reach your gas supplier, call

thoroughly before installing or servicing this equipment

the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

WARNING: For Outdoor Use Only. Do not use for cooking

Save this manual for future reference. Installer: Leave this manual with customer.

75,000BTU/Hr Manually Controlled

Page 2 of the Procom PL600HYLB user manual — Table of Contents
Page 2 · Contents
Contents

Contents

CAMPFIREp.1OWNER’S OPERATION AND INSTALLATION MANUALp.1PL600HYLA/PL600HYLBp.160,000BTU/Hr PN750HYLA/PN750HYLBp.1WHAT TO DO IF YOU SMELL GAS:p.1WARNING: For Outdoor Use Only. Do not use for cookingp.1GENERAL INFORMATIONp.2TABLE OF CONTENTSp.2GENERAL INFORMATION ……………………………………………………………….........2p.2SAFETY INFORMATION ………………………………………………………………...........3p.2INSTALLATION .……………………………………………………………………..……....... 5p.2OPERATING HEATER ………………………………………………..…………………........7p.2MAINTENANCE AND STORAGE ……………………………………………………..........8p.2PRODUCT FEATURES ……………………………………………………………………......9p.2SPECIFICATION …………………………………………………………….........…………...10p.2TROUBLESHOOTING ……………………………………………………………………... ..10p.2PARTS LIST …………………………………………………………… …………………….....11p.2SAFETY INFORMATIONp.3PROPER CLEARANCES FROM COMBUSTIBLE, CON-p.3THIS APPLIANCE SHOULD NEVER BE PLACEDp.3Locationp.3Location Continuep.4LOCAL CODESp.4Installationp.5LOGS LISTp.5PL600HYLA PN750HYLAp.5PL600HYLB PN750HYLBp.5Installation continuep.6INSTALLATION INSTRUCTIONS:p.6Installation (continue)p.7OPERATING HEATERp.7CONNECTING TO GAS SUPPLYp.7LIGHTING INSTRUCTIONSp.8WARNING:FOR YOUR SAFETY READp.8BEFOR LIGHTINGp.8MAINTENANCE AND STORAGEp.8PRODUCT FEATURESp.9SERVICE INDICATIONS:p.9SAFETY PILOTp.9PIEZO IGNITION SYSTEMp.9REPLACEMENTp.9REPLACEMENT PARTS:p.9*Option Screen*p.9For Your safetyp.9PARTS UNDER WARRANTY :p.9CAUTIONp.9PLEASE DO NOT TOUCH SCREEN OR PLACE ANYp.9OBJECTS ON SCREEN WHILE BURNER IS ONp.9PARTS NOT UNDER WARRANTY:p.9ACCESSORIESp.10TROUBLESHOOTINGp.10POSSIBLE CAUSEp.10REMEDYp.10PARTS LISTp.11PN750HYLA/PN750HYLBp.11ILLUSTRATEDp.12PARTS BREAKDOWNp.12PL600HYLA / PL600HYLBp.12PN750HYLA / PN750HYLBp.12WARRANTY INFOR ATIONp.13KEEP THIS WARRANTYp.13LIMITED WARRANTY PRO-COM OUTDOOR CAMPFIREp.13PRO-COM TOLLFREE NUMBER: 18778865989p.13
Page 3 of the Procom PL600HYLB user manual — Location
Page 3 · click to enlarge
Page 3

SAFETY INFORMATION

PROPER CLEARANCES FROM COMBUSTIBLE, CON-

THIS GAS APPLIANCE IS DESIGNED FOR OUTDOOR USE ONLY.

STRUCTION AND MATERIALS MUST BE MAINTAINED FROM ALL SIDES, TOP AND BOTTOM OF THIS

IT IS NOT INTENDED FOR INSTALLATION IN ANY BUIDING, GARAGE.OR ENCLOSED STRUCTION. IT IS NOT INTENDED FOR

APPLIANCE. THIS APPLIANCE SHOULD NEVER BE PLACED ON ANY COMBUSTIBLE SURFACE. THIS APPLIANCE SHOULD NEVER BE PLACED UNDER ANY COMBUSTIBLE CONSTRUCTION OR MATERIALS.

INSTALLATION IN OR ON RECREATIONAL VEHICLES OR BOATS.

this manual, prior to operation.

THIS APPLIANCE SHOULD NEVER BE PLACED

CLOSER THAN FORTY-EIGHT (48”) INCHES FROM ANY SIDE TO ANY COMBUSTIBLE CONSTRUCTION

and the products of combustion of such fuels, contain chemicals know to the State of California

OR MATERIALS.

to cause cancer, birth defects and /or other reproductive harm. This warning is issued pursuant

Location

to California Health & Safety Code Sec.25249.1

Your campfire can be installed on a flat, stable surface,

away from any combustible materials or construction. (See FIgure 13)

While this appliance is not in use, the gas must be turned off at the gas supply.

While this appliance is not in use, it should be covered

Place unit on any level, outdoor, non combustible surface.

to protect it from weather and other adverse elements.

DO NOT ATTEMPT TO DISCONNECT THE GAS OR ANY GAS FITTING WHILE THIS APPLIANCE IS IN OPERATION.

area , this may prevent proper venting.

HARD PIPING TO UNIT WITHOUT GAS PROXIMITY 1. TURN OFF THE GAS SUPPLY SYSTEM

Inspect the gas connections of this appliance prior to each use. Do not operate the unit if there is a gas leak

present. Do not put anything flammable, on or around or be-

Clean pipe threads using either a wire brush or steel wool. Apply Teflon tape or pipe dope to the steel

neath the campfire. NEVER Leave the campfire unattended while in

fittings before making any connection. BE CAREFUL! Make sure all gas connections are

operation. NEVER Allow children to operate this appliance.

snug, but not over tighten! 2. Extend the gas supply system using1/2” black iron

NEVER Lean over the campfire or place ,hand or fin- gers on the screen cover or near flame.

pipe from current house supply. This may be ac- complished by a teeing off” or tapping into a con-

NEVER Use liquid propane gas in a natural gas unit, or natural gas in a liquid propane unit. Gas conver-

venient gas line connection; installing the neces- sary pipe for the distance required; and then in-

sions SHOULD ONLY BE DONE BY A QUALIFIED SERVICE TECHNICIAN. DO NOT use charcoal bri-

stalling a manual valve at exterior house wall. If pipe is to pass though a foundation or house wall,

quettes or lighter fluid in any campfire. Storage of this appliance indoors is permissible only if

make sure to re-seal the area around the pipe with weather sealant.

the gas is disconnected.

3. From manual valve, extend piping to the campfire.
Page 4 of the Procom PL600HYLB user manual — LOCAL CODES
Page 4 · click to enlarge
Page 4

Location Continue

Storage of this appliance indoors is permissible only

if it has been disconnected from its fuel supply. (natural gas line or LP gas)

rial construction.

4. Connect the 3/8” male flare brass fitting (furnished

with campfire) to the 1/2” steel piping making sure to clean the pipe threads and use Teflon tape or pipe

LOCAL CODES

Install and use heater with care. Follow all local codes.

dope.(FLEX LINE NOT SUPPLIED) 5. Connect the 1/2” female X 3/8” male flare brass fitting to the 3/8” female brass flare fitting, as

In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANSZ223.1, also known

as NFPA54*. Available fromAmerican National Standards Institute, INC. 1430 Broadway, New York, NY10018

sembled on the right side of the gas line, of the right side of the campfire.

National Fire Protection Association, INC. Battery march Park Quincy. MA 02269

(Note: show drawing of hard piping installation.

Procom PL600HYLB — LOCAL CODES diagram (page 4)
Fig. 4

Do not use this appliance if any part has been under water. Immediately call a qualified service technician

to inspect the appliance and to replace any part of control system and any gas control which has been

under water.

Children and adults should be alerted to the hazards

of high surface temperatures and should stay away

to avoid burns or clothing ignition. Young children should be carefully supervised when

agency or gas supplier.

they are in the area of the appliance. Never leave the appliance unattended during

The appliance and its manual shutoff valve must be disconnected from the gas supply piping sys-

operation. Clothing or other flammable materials should not

tem during any pressure testing of the system at test pressures in excess of 1/2 psig (3.5kPa).

be placed on or near the appliance. ∙ Any guard or other protective device removed for

This appliance must be isolated from the gas

servicing the appliance must be replaced prior to operating the appliance

supply piping system by closing its manual shutoff valve during any pressure testing of the

∙ Installation and repair should be done by a quali-

gas supply piping system at test pressures equal to or less than 1/2 psig (3.5kPa).

fied service person.. The appliance should be in-

spected before use and at least annually by a quali- fied service person. More frequent cleaning may

be required as necessary. It is imperative the con- trol compartment, burners and circulating air pas-

sageways of the appliance be kept clean. ∙ Inspect the fuel supply connection before each use

of the appliance.

Page 5 of the Procom PL600HYLB user manual — PL600HYLB PN750HYLB
Page 5 · click to enlarge
Page 5

Installation

LOGS LIST

PL600HYLA PN750HYLA

Procom PL600HYLB — LOGS LIST diagram (page 5)
Fig. 5

FIG 2 The LOG sets for PL600HYLA/ PN750HYLA

PL600HYLB PN750HYLB

Procom PL600HYLB — PL600HYLB PN750HYLB diagram (page 5)
Fig. 6

FIG 3 The LOG sets for PL600HYLB/ PN750HYLB

Page 6 of the Procom PL600HYLB user manual — INSTALLATION INSTRUCTIONS:
Page 6 · click to enlarge
Page 6

Installation continue

Check to make sure you have the correct parts before

7. Install the No.#1 log as indicated on base log .Fix the log on the bracket by the screw .

assembling.

. Logs5

(FIG.-6).

Caution: Some of the steel edges may be sharp. Please use caution when assembling the unit.

Procom PL600HYLB — Installation continue diagram (page 6)
Fig. 7 · Installation continue

INSTALLATION INSTRUCTIONS:

1. Remove log from inside the box. Please note each log fits the number marked on foam package.
2. Next remove campfire from box. 3. You may use bricks or blocks to create your sur-

Fig. 6 Install the LOG #1

round to place your campfire on. 4. Make sure that the campfire is placed on a flat

surface. 5. Check the log piece (FIG-4).

8. Install the No.#2 log as indicated on base log.

(FIG.-7).

Procom PL600HYLB — INSTALLATION INSTRUCTIONS: diagram (page 6)
Fig. 8
Procom PL600HYLB — INSTALLATION INSTRUCTIONS: diagram (page 6)
Fig. 9

Fig.-4 Check the log piece

6. Make sure that the logs were installed correctly. (FIG.-5).(Base logs are pre-installed.)

Fig. -7 install the LOG #2

9. Install the No.#3 log as indicated on the base log ( FIG.-8).
Procom PL600HYLB — INSTALLATION INSTRUCTIONS: diagram (page 6)
Fig. 10
Procom PL600HYLB — INSTALLATION INSTRUCTIONS: diagram (page 6)
Fig. 11

Fig. -8 install the LOG #3

Fig.-5 Install and check the base logs

Page 7 of the Procom PL600HYLB user manual — CONNECTING TO GAS SUPPLY
Page 7 · click to enlarge
Page 7

Installation (continue)

FUEL REQUIREMENTSNatural gas models
11. install the No. # 4 log as indicated on the base

(FIG.-9).

l - Connect the ON/OFF gas valve of the appliance to the incoming gas supply line. See Figure 10. -

- Make certain all gas connections are right. - Turn the ON/OFF valve at the appliance slowly

Procom PL600HYLB — Installation (continue) diagram (page 7)
Fig. 12 · Installation (continue)

to the “ON” position. Use a soap and water solution to test for leaks.

Procom PL600HYLB — Installation (continue) diagram (page 7)
Fig. 13 · Installation (continue)

Fig. -9 Install the LOG #4

12. Install the No. #5 Log as indicated on the base log (FIG. 10).
Procom PL600HYLB — Installation (continue) diagram (page 7)
Fig. 14 · Installation (continue)

Fig. 11 Natural gas burner assembly

OPERATING HEATER

FIG. -10 Insatll the LOG #5

Your campfire burener is build to operate with natural gas or build for LP gas.

This appliance is lit a piezo ignitor, follow these instruc- tions exactly when lighting the campfire. BEFORE

CONNECTING TO GAS SUPPLY

LIGHTING, smell arround the appliance the appliance area for gas. Be sure to smell to next to the ground as

joints. Do not use an open flame. Bubbles forming show a leak. Check all connections for leaks

liquid propane gas heavier than air and will settle to the ground.

immediately.

Follow adaptable lighting instructions. Apply soap solu- tion to all joints. Bubbles forming indicates a leak. Do

not use a match or an open flame to detect leak. Light heater after ensuring that no gas leak exists.

Page 8 of the Procom PL600HYLB user manual — MAINTENANCE AND STORAGE
Page 8 · click to enlarge
Page 8

LIGHTING INSTRUCTIONS

TO TURN OFF GAS TO APPLIANCE Shutting Off Appliance

WARNING:FOR YOUR SAFETY READ

BEFOR LIGHTING

1. Turn control knob clockwise 90 degrees to the PILOT position.
1. STOP! Read the safety information above.
2. Press in and turn control knob clockwise 90 degrees to OFF position.
2. Make sure manual shutoff valve is fully open. 3. Press in and turn control knob clockwise 90

Shutting Off Burner Only (pilot stays lit) Turn control knob clockwise 90 degrees to the

degree to the OFF position. 4. Wait five (5) minutes to clear out any gas. Then

PILOT position.

smell for gas around log set and near floor. If you smell gas, STOP! Follow the safety information

Procom PL600HYLB — WARNING:FOR YOUR SAFETY READ diagram (page 8)
Fig. 15

above. If you don’t smell gas, go on to the next step. 5. Turn control knob counterclockwise 90

degree to the PILOT position and press in. Keep con- trol knob pressed in for five(5) seconds.

after hooking up to gas supply. If so, the control

knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

Fig12 The operationg board

6. With control knob pressed in, push down and release ignitor button. This will light the pilot. The pi-

lot is attached to the side of the front burner. If needed, keep pressing ignitor button until pilot

MAINTENANCE AND STORAGE

lights. NOTEIf pilot does not stay lit, contact a qualified
1. Storage of an appliance indoors is permissible

only if the gas supply system is disconnected and removed from the appliance. .

service person or PRO-COM’s 800# on the back of this manual. Until repairs are made, light pilot

2. Have the heater inspected by qualified service man before each use or at least annually.

with the piezo. 7. Keep control knob pressed in for 30 seconds after

3. Check the POL fitting for any damage before each use and replace if any damage is found.

lighting pilot. After 30 seconds, release control knob. Note: If pilot goes out, repeat steps 3 through 7.

4. Spiders and insects can nest and live in outdoor appliances, especially in the burners and orifices.

If control knob does not pop up when released, con-

tact a qualified service person or PRO-COM’s 800#

This will interrupt the normal flow of LP gas to the heater and can be a very dangerous situation.

on the back of this manual. 8. Turn control knob counterclockwise 90

Inspect for insect infiltration of burner/orifice when one of the following occurs:

degree to the ON position. Burner should light. If burner does not light, call a qualified service person

A. The smell of gas along with predominating yel-

or PRO-COM’s 800# on the back of this manual.

low tipping of the burner flames.

B. Heater can not reach desired temperature. C. Uneven burner flow.

structions exactly, a fire or explosion may result causing property damage, personal in-

D. Burner makes popping noises during normal

use or shutdown.

jury or loss of life.

5. Adopt rainproof cover (provided with the heater) to avoid rust of heater when not in use.
Page 9 of the Procom PL600HYLB user manual — PARTS NOT UNDER WARRANTY:
Page 9 · click to enlarge
Page 9

PRODUCT FEATURES

SERVICE INDICATIONS:

SAFETY PILOT

A hazardous condition may result if a heater has been

modified or is not functioning properly. When the heater is working properly:

The heater has a pilot with a safety shutoff system.

The safety pilot is a required feature for outdoor heaters. It shuts off the heater if flame is extinguished

1. The flame is essentially yellow.

by rough wind.

2. There is no strong disagreeable odor, eye burning or other physical discomfort.

PIEZO IGNITION SYSTEM

This heater has a piezo igniter. This system requires

3. No smoke or soot exists internal or external to the

campfire.

no matches, batteries, or other sources to light heater.

4. No unplanned or unexplained shut down of the

VALVE CONTROL SYSTEM This heater has a control valve to control the gas flow,

heater occur.

with the control valve, you can chose the proper flame of the fire.

REPLACEMENT

REPLACEMENT PARTS:

*Option Screen*

protect your warranty coverage for parts replaced un- der warranty.

For Your safety

You may purchase the screen to maintain a clearance

PARTS UNDER WARRANTY :

Contact authorized dealers of this product. If they can’t

CAUTION

supply original replacement part(s) call PRO-COM’s Technical Service Department at 1-877-886-5989 for

PLEASE DO NOT TOUCH SCREEN OR PLACE ANY

OBJECTS ON SCREEN WHILE BURNER IS ON

referral information.

When calling PRO-COM or your dealer, have ready

Children and adults should be alerted to the hazards

Your name Your address

of high surface temperatures and should stay away

from SCREEN to avoid burns or clothing ignition,

Model and serial numbers of your heater How heater was malfunctioning

Procom PL600HYLB — PLEASE DO NOT TOUCH SCREEN OR PLACE ANY diagram (page 9)
Fig. 16

Type of gas used (propane/LP or natural gas) Warranty card

Usually, we will ask you to return the defective part back to retail store.

PARTS NOT UNDER WARRANTY:

Contact authorized dealers of this product or Parts

Central if they can’t supply original replacement part (s) Call PRO-COM’s Parts Department at 1-877-886-

5989 for referral information.

When calling PRO-COM, have ready

Model number of your heater The replacement part number

FIG. 13 The screen

around the campfire

Page 10 of the Procom PL600HYLB user manual — REMEDY
Page 10 · click to enlarge
Page 10

ACCESSORIES

HIGH ALTITUDE DERATE Purchase the accessories from your local dealer or Parts Central. If they cannot supply these accessories

In the U.S.A., Input BTU shall be derated 4%(1 orifice

size) per 1000ft, for above 2000ft.. In Canada, input BTU shall be derated 10% (2 orifice size) at altitudes from

call PRO-COM’s Sales Department at 1-877-886-5989 for referral information. You can also write to the ad-

2000ft.to 4500ft..

dress listed on the back page of this manual.

SPECIFICATIONS Model L600HYLA/B PN750HYLA/B Btu (LP/NG) 60.000 75.000 Gas Type LP NG Ignition Piezo Piezo Inlet Gas Pressure* (In. of water) Maximum 14” 10.5” Minimum 11” 5.5” Dimensions, Inches (H x W x D) Stove 17 3/4” x22 7/8”x18 1/8” 17 3/4” x22 7/8”x18 1/8” Carton 15” x25 ”x20 1/4” 15” x25 ”x20 1/4” Weight, Lbs Stove 32/33 32/ 33 Shipping Weight 55/58 55/ 58

* For purpose of shipment adjustment. Minimum clearances: Bottom: (This appliance may not be place on any combustible materials)

Top8 FT. (2.4m)
Side /walls (around)48 inch (1220mm)

TROUBLESHOOTING

POSSIBLE CAUSE

OBSERVED PROBLEM Burner does not light

REMEDY

1. Air in gas lines.
1. Continue holding down control knob. Repeat igniting operation until air is

removed. 2. Check gas pressure.

2. Inlet gas pressure is too low.
3. Gas supply turned off. 4. Air passageway on heater blocked.
3. Fully open gas supply. 4. Check air passageway.
5. Burner orifice clogged. 6. Control knob not in ING/ON position.
5. Clean burner. 6. Turn control knob to ING/ON position.
7. Control knob not fully pressed in while in ING/ON position.
7. Press down control knob.
1. Ignitor electrode positioned wrong.
1. Reposition ignitor.
2. Ignitor broken. 3. Broken ignitor cable.
2. Replace pilot 3. Replace ignitor cable.

pressed in, there is no spark at safety Pilot.

4. Ignitor electrode not connected to ignitor cable.
4. Connect electrode to ignitor cable.
1. Damaged thermocouple.

1.Replace thermocouple.

Burner fire does not last.

2. Thermocouple electrode corrosion. 3. Damaged control valve.
2. Clean thermocouple electrode. 3. Replace control valve.
4. Control knob not pressed long enough.
4. After pilot lights, keep control knob pressed in for 30 seconds.
5. Thermocouple connection loose at control valve.
5. Hand tighten connection or replace thermocouple.
6. Pilot flame not touching thermocouple.
6. Contact qualified service man.

When ignitor buttons

Page 11 of the Procom PL600HYLB user manual — PL600HYLA/PL600HYLB
Page 11 · click to enlarge
Page 11

PARTS LIST

PL600HYLA/PL600HYLB

PN750HYLA/PN750HYLB

Procom PL600HYLB — PL600HYLA/PL600HYLB diagram (page 11)
Fig. 17
Page 12 of the Procom PL600HYLB user manual — PARTS BREAKDOWN
Page 12 · click to enlarge
Page 12

ILLUSTRATED

PARTS BREAKDOWN

PL600HYLA / PL600HYLB

PN750HYLA / PN750HYLB

Procom PL600HYLB — PARTS BREAKDOWN diagram (page 12)
Fig. 18
Page 13 of the Procom PL600HYLB user manual — PRO-COM TOLLFREE NUMBER: 18778865989
Page 13 · click to enlarge
Page 13

WARRANTY INFOR ATION

KEEP THIS WARRANTY

Model:

Serial No.

Always specify model and serial numbers when communicating with PRO-COM.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We

make no other warranty, expressed or implied.

LIMITED WARRANTY PRO-COM OUTDOOR CAMPFIRE

PRO-COM warrants this product to be free from defects in materials and components for one (1) years from the date of first purchase, provided

that the product has been properly installed, operated and maintained in accordance with all applicable instructions, to make a claim under this

warranty, the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper

operating condition and an allowance for labor when provided by a PRO-COM Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or PRO-COM who will provide original factory replacement parts. Failure to use original factory

replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions

furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transporta-

tion and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT, THIS EXPRESS WAR- RANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES

INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO ONE (1) YEAR ON ALL COMPONENTS FROM

THE DATE OF FIRST PURCHASE. NANJING PRO-COM’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND NANJING PRO-COM SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT. ACCIDENTAL OR CONSEQUEN-

TIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of accidental or consequential damages,

the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.

This warranty gives you specific legal right, and you may also have other rights that vary from state to state.

For information about this warranty please write to:

NANJING PRO-COM ELECTRIC APPLIANCE CO., LTD.

#6 CHUANGYE ROAD, HIGH NEW TECHNOLOGY & DEVELOPMENT ZONE,

GREAT BRIDGE ROAD NORTH, NANJING, 210061, CHINA.

PRO-COM TOLLFREE NUMBER: 18778865989

Date Purchased · Patent Pending

Ask about the Procom PL600HYLB

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Procom PL600HYLB

Be the first to ask — other owners or our team will answer.

Original document

Procom PL600HYLB manual PDF

13 pages·591 KB·Outdoor Fireplace·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…