EN
Precisionaire logo
Official user manual

Precisionaire PB1003

2 pages·156 KB·Air Cleaner·PDF·ENDEFRITNLJA
Precisionaire PB1003
Table of Contents 8 sections General · Physical Data · Important Features · Flanders Filters - Foremost in Air Filtration · … ShowHide
Page 1 of the Precisionaire PB1003 user manual — Flanders Filters - Foremost in Air Filtration
Page 1 · click to enlarge
Page 1
Precisionaire PB1003 — General diagram (page 1)
Fig. 1 · General

General

The media is designed for operation in high tem- perature applications and manufactured from one continuous sheet of wet-laid micro-fine fiberglass, which provides the required tensile strength and operating pressure drop for these stringent applica- tions.

PrecisionCell HT filters are designed for high tem- perature applications up to 900o F. They feature the same rugged construction as the Gas Turbine PrecisionCell. The HT version is manufactured of specially selected components to meet high temper- ature requirements.

Physical Data

They are ideal for paint drying ovens or any appli- cation requiring high efficiency filtration at high tem- peratures. PrecisionCell HT filters are offered in two high temperature operating ranges; 750ºF and 900º F and efficiency ranges of 65%, 85% and 95% per ASHRAE Standard 52.1. Offered as a MERV 11-14 according to ASHRAE 52.2. Construction

Frame24 ga. aluminized steel
MediaDual layer microfine fiberglass
SeparatorsHemmed-edge corrugated aluminum
Header Frame7/8” wide aluminized steel
FaceguardsAluminized steel expanded
Cross Bracing1/2” “T” strap downstream and horizontal strap upstream

The enclosing frame is manufactured of aluminized steel, which is designed to eliminate spalling of cor- rosion inhibitors @ elevated temperatures.

The media pack is stabilized by a media pack retaining bar and captured by faceguards upstream and downstream. Grid strap bracing on the air entering and leaving sides maintain the rigidity and integrity of the PrecisionCell HT.

Precisionaire PB1003 — Physical Data diagram (page 1)
Fig. 2 · Physical Data

Important Features

  • Continuous duty up to 900 º F
  • Aluminized steel construction
  • 65%, 85%, 95% efficiencies
  • Faceguards and grid straps
  • MERV 11 to 14

Flanders Filters - Foremost in Air Filtration

Toll Free: 1-800-637-2803

Page 2 of the Precisionaire PB1003 user manual — REPRESENTED BY:
Page 2 · click to enlarge
Page 2
EfficiencyOperating Limit ºFNominal Size H x W x D (inch)500 fpm RatingMedia Area (sq. ft.)Weight Each (lbs) cfmpd 60-65%75024 x 24 x 12 24 x 12 x 122000 1000.45140 6926 21 90024 x 24 x 12 24 x 12 x 122000 1000.50175 9028 22 80-85%75024 x 24 x 12 24 x 12 x 122000 1000.55140 6926 21 90024 x 24 x 12 24 x 12 x 122000 1000.60175 9028 22 90-95%75024 x 24 x 12 24 x 12 x 122000 1000.65140 6926 21 90024 x 24 x 12 24 x 12 x 122000 1000.70175 9028 22

1. PD represents clean pressure drop in inches w.g. The recommended final pressure drop is 2.5 inch w.g. 2. Operation down to zero velocity is satisfactory for all models. 3. Efficiencies are average and are based on ASHRAE Standard 52.1 and 52.2 dust spot test methods. Performance values stated may be averages typical of the products listed. Contact factory for actual perform- ance test reports on specific products. 4. Perfmormance values shown in this publication may be averages or estimates intended to generally represent product styles. Always contact factory for latest actual test data on specific Flanders Precisionaire models.

Guide Specifications

1.0 General

2.3 Expanded metal aluminized steel faceguards shall be installed on the air entering and air leav- ing sides.

1.1 High temperature rigid filters shall be PrecisionCell HT separator type as manufactured by Flanders.

2.4 A 1/2” “T” strap shall be installed on the down- stream side and 1/2” horizontal strap on the air entering side.

1.2 Filter sizes and temperature ranges shall be as scheduled on the drawings.

2.0 Filter Construction

3.0 Performance

3.1 Initial and final resistance shall not exceed the scheduled values.

2.1 Filters shall be constructed by pleating a contin- uous sheet of wet-laid micro-fine glass media into closely spaced pleats with hemmed-edge corrugated aluminum separators.

3.2 Media area shall equal that of the scheduled high temperature filter.

2.2 The filter pack shall be sealed into a 24 ga. aluminized steel frame with fire-retardant sealant.

3.3 The manufacturer shall guarantee performance as outlined in section 7.4 of ARI Standard 800.

REPRESENTED BY:

Flanders - PrecisionAire

Foremost in Air Filtration Toll Free: 1-800-637-2803

Ask about the Precisionaire PB1003

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.