EN
Precisionaire logo
Official user manual

Precisionaire Alpha 95

4 pages·403 KB·Air Cleaner·PDF·ENDEFRITNLJA
Precisionaire Alpha 95
Table of Contents 10 sections Alpha 95 · 95% DOP Filter Bulletin PB1400-1106 · General · Installation Considerations · … ShowHide
Page 1 of the Precisionaire Alpha 95 user manual — Important Features
Page 1 · click to enlarge
Page 1

Alpha 95

95% DOP Filter Bulletin PB1400-1106

F O R E M O S T I N A I R F I LT R AT I O N

General

Standard Alpha 95 filters have 1.7 times the cfm capacity of standard Alpha Cell 99.97% DOP HEPA filters at the same clean pressure drop. They are normally rated at 500 fpm so that filter banks with 95% DOP filters can be sized the same as ASHRAE-rated filter banks.

Flanders Alpha 95 filters are designed for use in HVAC applications requiring cleaner air than is possible with ASHRAE rated filters, but where HEPA filtered air is not required. The filters are rated at 95% efficiency on 0.30 micrometer particles by the DOP test method. The Alpha 95 is rated MERV 17 per ASHRAE Standard 52.2.

Typical applications for Alpha 95 include:

Alpha 95 filters are identical in design and con- struction to the Alpha Cell HEPA filters except that the media is 95% efficient on 0.30 micrometer par- ticles.

  • Hospitals
  • Biomedical
  • Pharmaceutical

Installation Considerations

  • Biotechnology
  • Genetic Research

Alpha 95 filters should be installed in Flanders leak tight Alpha HEPA frames or Surelock Side Access HEPA Housings on the positive-pressure side of the system fan to prevent air bypass. Sureaire diffuser sections, air mixing baffles or long transitions should be used if the bank is close to the fan.

  • Universities
  • Laboratories
  • Food Processing
  • Photo Processing
  • Semiconductor Fabrication

Installation of Flanders ASHRAE efficiency prefilters upstream of the fan is recommended to ensure economical Alpha 95 filter life.

  • Industrial Processing Systems Product
Precisionaire Alpha 95 — Installation Considerations diagram (page 1)
Fig. 1 · Installation Considerations

Important Features

  • Minimum efficiency is 95% on 0.30 micrometer particles.
  • Manufactured in a variety of wood and metal frame types.
  • Available with a media pack with aluminum separators or with a separatorless pack.
  • Available in a variety of sizes with either a gasket or gel seal.

®

Page 2 of the Precisionaire Alpha 95 user manual — Alpha 95 Pressure Drop vs. Air Velocity
Page 2 · click to enlarge
Page 2
CFM CAPACITIES AND DIMENSIONS Frame Depth (Inches)Filter Size & Frame Depth DesignatorActual Face Size (inches)cfm Capacity at Clean Pressure Drop inches w.g.Weight (Lb.) .651.01.35 11-1/2GG-F24 x 2413752000256038 GC-F24 x 12650920118026 YY-F23-3/8 x23-3/813501900245037 YU-F23-3/8 x11-3/8610865115025 GN-F24 x 3017502550325045 14 CC-F12 x 12290430550
Precisionaire Alpha 95 — Construction diagram (page 2)
Fig. 2 · Construction

Construction

Flanders manufactures both conventional Separator Style and Pureform Separatorless 95 DOP filters. To make a Separator Style filter, the media is folded over corrugated aluminum sepa- rators with hemmed edges to separate the pleats in the filter pack. Flanders manufactures its own filter media, enabling it to develop a unique manufacturing process for the production of Pureform Separatorless 95% DOP filters. In one manufacturing operation, Flanders produces a self-supporting and self-sepa- rating Pureform Media Pack.

Alpha 95 with separator Style Media Pack

The Pureform filter offers many advantages over conventional Separator Style 95% DOP Filters:

  • Increased usable media area affords longer service life and higher dust holding capacity
  • Maximum utilization of the media
  • Can handle some harsh environments which may attack aluminum separators
  • Media pack can be incinerated
  • Media is 28 mils, significantly thicker than conventional media used in Separator Style 95 DOP filter (15 mil)
  • Pureform has 25% more media area than conventional style.

Alpha 95 with Pureform Media Pack

  • Ideal for heavy loading applications such as oil mist.

Alpha 95 Pressure Drop vs. Air Velocity

Pressure Drop (in. w.g.)

0 125 250 375 500 625

Air Velocity (fpm)

Page 3 of the Precisionaire Alpha 95 user manual — D = 5-7/8” F = 11-1/2”
Page 3 · click to enlarge
Page 3

ALPHA 95 COMPONENT CHART

0. 00J - W - 08 - 03 - IU - 12 - 00 - GG - F

Hardware 0 = None T = Extractor Clips Efficiency 00J = 95% DOP Capacity/Pack Style C = Separator D = 4 inch Pureform F = 8 inch Pureform W = 11 inch Pureform Frame Material 02 = 16 GA 409 Stainless 03 = 16 GA 304 Stainless 04 = 3/4 in. FIRE RETARDANT PLYWOOD 05 = FABRICATED ALUMINUM 07 = 3/4 in. FIRE RETARDANT PARTICLE BOARD 08 = 16 GA. GALVANNEAL 11 = 3/4 in. NON FIRE RETARDANT PARTICLE BOARD 16 or 17 = CORROSION-RESISTANT 24 GA. STEEL Frame Style 00 = BOX 01 = SINGLE HEADER (13/16”) 02 = DOUBLE HEADER (13/16”) 03 = DOUBLE TURNED FLANGE 05 = 3/4 IN. DEEP CHANNEL GEL SEAL 08 = DOUBLE-TURNED FLANGE, ONE SIDE Sealant Material IU = URETHANE IH = HOT MELT Gasket material Gasket location 0 = NONE 0 = NONE 1 = NEOPRENE 1 = UPSTREAM 5 = BLUE JEL 2 = DOWNSTREAM 3 = BOTH SIDES

D = 5-7/8” F = 11-1/2”

Filter Face Size (HxW) B = 8” N = 30” R = 60” C = 12” P = 36” S = 72” E = 18” H = 42” U = 11-3/8” G = 24” Q = 48” Y = 23-3/8”

Odd Size Designator Odd size designators are an Alpha Numeric description. The first two digits specify the height whole number with an alpha designator specifying the height fraction. The second two digits specify the width whole number with an alpha designator specifying the width fraction. And the last alpha designator specifies the depth. If the height or width is less than 10 inches, use a 0 in front of the dimension.

A = 0” F = 5/16” L = 5/8” B = 1-1/16” G = 3/8” M = 11/16” C = 1/8” H = 7/16” N = 3/4” D = 3/16” J = 1/2” P = 13/16” E = 1/4” K = 9/16” Q = 7/8” R = 15/16”

Faceguard Material Faceguard Location 0 = NONE 0 = NONE 1 = GALVANIZED 4X4 MESH 1 = UPSTREAM G = ALUMINIZED EXPANDED METAL 2 = DOWNSTREAM 2 = 17GA. SS 4X4 MESH 5 = 22 GA. SS 4X4 MESH

Frame: Alpha 95 filters are available in a variety of wood and metal frame materials such as particle board, plywood, galvanized steel and stainless steel. Alpha 95 filters are also available in 24 gauge corrosion resistant steel in single or double headers for installation in side access or plenum applications.

Seal: The standard gasket seal is 0.75” x 0.25” neoprene for installation on either the upstream, downstream or both sides of the filter. The standard Fluid Seal is Flanders Blu-Jel® Seal which is a two-part silicone material suitable for temperatures up to 390°F.

Faceguards: Faceguards are used to protect the filter media from mechanical damage. The typical faceguard material is expanded aluminized steel. Galvanized 4 x 4 mesh welded wire and Type 304 stainless steel faceguards are also available.

UL: Alpha 95 filters are either UL900 Class 1 or Class 2 listed depending on materials of construction.

Banks: Alpha Frames are designed for Alpha 95 filters in built-up filter banks. Each filter is secured in the frame with four bolt-type fasteners that either compress the gasket or press the knife edge into the gel in the filter channel to maintain a leak-tight seal. Surelock B or C-3 gasket seal and Surelock C-4 for Blu Jel HEPA Filter Housings are recommended for side-access applications. The filters are sealed in place with either spring-loaded swing arm assem- blies or a locking mechanism. The swing arm assemblies or locking mechanism either compress the gasket or press the knife edge into the gel in the filter channel to maintain a leak-tight seal.

Filter Depth

Page 4 of the Precisionaire Alpha 95 user manual — Guide Specifications
Page 4 · click to enlarge
Page 4

Guide Specifications

1.0 General

1.1 Alpha 95 filters shall be extended media (separator type) (Pureform separatorless type) filters as manufactured by Flanders.

2.2 The filter pack shall be sealed into a (galvaneal) (409 stainless steel) (304 stainless steel) (particleboard) (fire retardant particleboard) (fire retardant plywood) frame with a fire retardant (polyurethane foam) (solid urethane) sealant. (Steel frames shall be 16 ga.) (Wood frames shall be 3/4” thick.)

1.2 Filter sizes, capacities and construction op- tions shall be as scheduled on the drawings.

1.3 Filters shall be (UL 900 Class 1)( UL 900 Class 2) listed.

2.3 (A 40-durometer closed-cell neoprene gasket) (Silicone gel in a channel) shall be provided on one or more sides to seal the filter in the mounting device.

2.0 Filter Construction

2.1 The filter pack shall be constructed by pleat- ing a continuous sheet of non-woven water- resistant fiberglass media around hemmed- edge corrugated aluminum separators. The filter pack shall be constructed by pleating a continuous sheet of formed, corrugated me- dium so that the pack is self-supporting without the use of spacers of any kind, including separators, tape strings, adhesives or strips of media.

3.0 Performance

3.1 Initial and final resistances shall not exceed the scheduled values.

3.2 The rated minimum efficiency of 95% on 0.3 micrometer size particles shall be as determined by the DOP Test Method

® Flanders Filters, Inc. 531 Flanders Filter Road Washington, NC 27889 Phone: (252) 946-8081 Fax: (252) 946-3425 Toll Free: (800) 637-2803Represented By: rs Filters ~ Foremost in Air Filtration Toll Free: 1-800-637-2803 Flanders Filters ~ Foremost in Air Filtration Website: www.flanderscorp.com Toll Free: 1-800-637-2803 4rs Filters ~ Foremost in Air Filtration Toll Free: 1-800-637-2803

Ask about the Precisionaire Alpha 95

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.